}

Tender For Maintenance Of Footpath, Culvert, Boundary Wall, Fencing Etc Of Zone I, Ii And Repair Maintenance Of Various Ceiling Fans, Wall Mounted Fans, Air Circulator And Exhaust Fan And Connected Works At Dinjan Under Ge Dinjan, dinjan-Assam

Military Engineer Services-MES has published Tender For Maintenance Of Footpath, Culvert, Boundary Wall, Fencing Etc Of Zone I, Ii And Repair Maintenance Of Various Ceiling Fans, Wall Mounted Fans, Air Circulator And Exhaust Fan And Connected Works At Dinjan Under Ge Dinjan. Submission Date for this Tender is 08-06-2023. Footpath Work Tenders in dinjan Assam. Bidders can get complete Tender details and download the document.




Tender Notice

37665147
Corrigendum : Tender For Maintenance Of Footpath, Culvert, Boundary Wall, Fencing Etc Of Zone I, Ii And Repair Maintenance Of Various Ceiling Fans, Wall Mounted Fans, Air Circulator And Exhaust Fan And Connected Works At Dinjan Under Ge Dinjan
Open Tender
Indian
Assam
dinjan
08-06-2023

Tender Details

Tender For Maintenance Of Footpath, Culvert, Boundary Wall, Fencing Etc Of Zone I, Ii And Repair Maintenance Of Various Ceiling Fans, Wall Mounted Fans, Air Circulator And Exhaust Fan And Connected Works At Dinjan Under Ge Dinjan

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-May-2023 CORRIGENDUM BOQ 01-06-2023
2 16-May-2023 CORRIGENDUM Other 01-06-2023
3 01-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-06-2023
4 01-Jun-2023 CORRIGENDUM OF TENDER DOCUMENTS Other 08-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work: MAINT OF FOOTPATH, CULVERT, BOUNDARY WALL, FENCING ETC OF ZONE I &IIAND REPAIR MAINT OF VARIOUS CEILING FANS, WALL MOUNTED FANS, AIR CIRCULATOR, AND EXHAUST FAN AND CONNECTED WORKS AT DINJAN UNDER GE DINJAN.
Sl. No. Item Description
1Demolition of brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
2M&L for brick work with sub class "B" bricks straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
3M&L for brick work with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and as directed.
4M&L for rendering 15 mm thick in cement mortar (1:6) on other than fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
5Demolition of unreinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
6M&L for hardcore of broken bricks, guage not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
7M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
8M&L for plain cement concrete (1:3:6)type C2 (40 mm graded aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
9M&L for machine pressed precast conctete interlocking paver block, design & shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment including 75 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. complete all as specified and as directed.
10M&L for chequered cement concrete tiles of size 20cmx20cmx25mm thick, as in floors etc,including 15 mm thick screed bed or bedding in cement mortar (1:6) and set and jointedin neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and as directed.
11M&L for 75 mm thick plain cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base of floor, etc complete all as specified and as directed.
12M&L for 40mm thick, plain cement concrete (1:2:4) type B-1, (using 20 mm graded stone aggregate) as in floor etc complete all as specified and as directed.
13Dismantling posts or struts (wood, steel or RCC) any section embedded in concrete, brick work, masonry etc, including taking out embedded portion concrete, brick work, masonry work, etc and making good disturbed ground complete all as specified and as directed.
14Dismantling fencing wiremesh, any type, any size complete all as specified and as directed.
15S&F for mild steel angle posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets ( for securing wire mesh etc) including all necessary drilling, bolting or riveting etcand similar work conforming to Fe-290 (Gde E-165) complete all as specified and as directed.
16Supply only chain link mild steel galvanised fencing any size or type 4 mm dia galvanized wire (100x100) mm mesh made upto matress lapped wire and laid on position / fixed on poles complete all as specified and as directed.
17Fixing only chain link fencing incl line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and as directed.
18S&F for galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed.
19M&L for mild steel round bars of Fe 290 (Gde -E-165) 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
20S&F for mild steel screw bolts of 11 to 15mm dia of shank (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exceeding 5cm long complete all as specified and as directed.
21Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and as directed.
22M&L for reinforced concrete pipes, class NP2, 600 mm bore, laid and jointed with collars complete all as specified and as directed.
23M&L for reinforced concrete pipes, class NP2, 300 mm bore, laid and jointed with collars complete all as specified and as directed.
24M&L for plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete for 300 mm bore drain pipes complete all as specified and as directed.
25M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggragate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 600 mm bore pipes complete all as specified and as directed .
26M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and as directed.
27M&L for preparation of new steel surfaces of any description, not exceeding 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and as directed.
28E/M ITEMS:
29Taking down carefully existingceiling fan of any size/sweep/make from it"s existingposition, replacement of defective spare parts and re-assembling and refixing/hanging in the same position connecting with flexiable cable including testing complete all as specfied and as directed. Note : Cost of spare parts and flexible connection wire asrequired will be measured and paid separately under respective items of this Schedule as "Supply only".
30All as per item No 29 here-in-above but exhaust fan/ wall fan of any sweep/any make.
31Dismantling ceiling fan (any size/sweep/make) and taking out existing burnt out winding wire of motorand rewinding the same after proper cleaning with super enamelled copper wires as per existing gauge and turn to achieve the desired RPM, cleaningandreplacement of bearings, bushes, capacitor etc as required and testing complete on completion for old modelceiling fan of super enamelled copper winding wire as per requirement and testingcomplete all as specfied and as directed. Note : (a) Replacement of unserviceable parts like capacitor, bearing, bush and flexible wire shall be measured and paid separately as "Supply only" under respective items of this Schedule. (b) Ceiling fan shall be collected from MES Store of GE Dinjan and AGE E/M and deposited to Store after repair, cost of which is deemed to be included in unit quoted rate.
32Dismantling of exhaust fanany make and taking out existing burnt out winding wire of motor and rewinding the same with super enamelled bare insulated copper winding wires as per existing gauge and turn to achieve desiredRPM including cleaning and replacement of defective parts as required for exhaust fan of size up to 380 mm sweep and testing all complete all as specfied and as directed. Note : (a)Replacement of unserviceable parts shall be measured and paid separately as "Supply only" under respective items of this Schedule. (b) Exhaust fan shall be collected from MES Store of GE Dinjan and AGE E/M Mohanbari and deposited to Store after repair, cost of which is deemed to be included in unit quoted rate.
33All as per item No 32 here-in-above but exhaust fan/ wall fan of450mm to 600mm sweep.
34All as per item No 32 here-in-above but wall fan of600mm sweep and above of three phase type .
35Repair to fan shaft by filing metal cutting by machine, grinding, polishing complete and making the same in serviceable condition suitable for existing ceiling fan of any capacity complete all as specfied and as directed.
36Supply only capacitor (oil filled) of capacity 2.0 mfd complete all as specfied and as directed. Make : Havells/Universal /Tibcon/Sarda/Usha.
37Supply only capacitor (oil filled) of capacity 2.5 mfd complete all as specfied and as directed. Make : Havells/Universal /Tibcon/Sarda/Usha.
38Supply only capacitor (oil filled) of capacity 3.15 mfd complete all as specfied and as directed. Make : Havells/Universal /Tibcon/Sarda/Usha.
39Supply only ball bearing No 6200 complete all as specfied and as directed. Make : TATA/SKF/NBC/HCH.
40Supply only ball bearing No 6201 complete all as specfied and as directed. Make : TATA/SKF/NBC/HCH.
41Supply only ball bearing No. 6202 complete all as specfied and as directed. Make : TATA/SKF/NBC/HCH.
42Supply only ball bearing No 6203 complete all as specfied and as directed. Make : TATA/SKF/NBC/HCH.
43Supply only ball bearing No 6204 complete all as specfied and as directed. Make : TATA/SKF/NBC/HCH.
44Supply only ball bearing suitable for exhaust fan of upto 380 mm sweep complete all as specfied and as directed. Make : TATA/SKF/NBC.
45Supply only ball bearing suitable for exhaust fan of 450 mm to 600 mm sweep complete all as specfied and as directed. Make : TATA/SKF/NBC.
46Supply only gun metal bush suitable for any type of ceiling fan complete all as specfied and as directed.
47Supply only gun metal bush suitable for any type and any sweep of wall fan/exhaust fan complete all as specfied and as directed.
48Supply only flexible wire twisted twin core of size 0.75 Sqmm, copper conductor complete all as specfied and as directed. Make : Finolex/ Havell"s/KEI/Polycab.
49M&L for single coat painting to ceiling fan upto 1400mm sweep after dismantling blades, with 1st grade quality synthetic enamel paint by spraying, filling cavities with filler including necessary preparation of surface duly demarking MES fan serial Nos, refixing the blades and re-writing MES Fan serial number complete all as specfied and as directed.
50M&L for single coatpainting to exhaustfan/ wall fan upto 380mm sweep with 1st grade quality synthetic enamel paint by spraying, filling cavities with filler including necessary preparation of surface duly demarking the MES Fan Nos and re-writing MES fan serial number complete all as specfied and as directed.
51M&L for single coatpainting to exhaustfan/ wall fan from 400 to 600mm sweep with 1st grade quality synthetic enamel paint by spraying, filling cavities with filler including necessary preparation of surface duly demarking the MES fan Nos and re-writing MES Fan serial number complete all as specfied and as directed.
52M&L for cutting holes in circular shape in brick walls exceeding half brick but not exceeding one brick thick in cement mortar for fixing exhaust fan and making good disturbed surfaces in cement mortar (1:3) finished even and smooth and to match with existing as required complete all as specfied and as directed.
53S&F in repair down rod heavy duty with 20mm dia MS rod for hanging ceiling fan not exceeding 0.5 mtr and fixing complete including joist of suitable size, nuts, bolts and washer with 2 Nos rubber insulator including drilling holes as required including necessary painting complete all as specfied and as directed.
54S&F in repair mild Steel "S" shape clamp made out of flat iron of size 25 x 6 mm with nuts and bolts of appropriate size as required for hanging of ceiling fan and necessary painting etc including taking out old/unserviceable one complete all as specfied and as directed.
55S&F in repair rubber insulator reel type suitable for fan hook of any type complete all as specfied and as directed.
56Taking out unserviceable canopy set and replacing the same with new PVC canopy set one as per existing specification as approved.
57Taking down carefully existingceiling fan of any size/sweep/make from it"s existingposition, dismantling the fan including preventive maintenance by servicing, greasing, oiling, cleaning external surfaces porperly and replacement of defective spare parts and re-assembling and refixing/hanging in the same position connecting with flexiable cable including testing complete all as specfied and as directed. Note : (a) Cost of spare parts and flexible connection wire asrequired will be measured and paid separately under respective items of this Schedule as "Supply only". (b) Rate of split pin, nut bolt, rubber grip and screw/washer, for fixing the blade shall be included in the quated rate.
58S&F for PVC holder for holding capacitor (condenser housing) of any size in ceiling fan complete all as specified and as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail