Kancheepuram Municipality-agecode007 has published Tender For Maintenance Of Water Supply For The 2022-23 Pumping Main And Distribution Main And Valves At Thiruparkadal Pumping Station To Vegavathy Pumping Station At Kancheepuram Corporation.. Submission Date for this Tender is 18-05-2023. Valve Tenders in kancheepuram Tamil Nadu. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Dismantling the existing Cement Concrete pavement and clearing away the debris from the site etc., complete as per standard specification as directed by the Departmental Officers. |
2 | Dismantling the existing BT Surface and clearing away the debris from the site etc., complete as per standard specification as directed by the Departmental Officers. |
3 | Earth work excavation for pipe line laying in all sub soils and to full depth as may be directed except hard rock requiring blasting inclusive of shoring shuttering, and bailing out of water with initial leads and lifts etc., complete as per standard specification. (Basic rate of five time leaks) |
4 | Supplying and filling in foundation and basement with filling clear river sand in layers of not more than 15cm thick, well rammed, watered and consolidated including cost and conveyance of sand at site and all labour charges and other incidental charges etc., complete complying with std specification. |
5 | Supplying and erecting steel centering includingnecessary supports for plane surfacesfor Reinforcement concrete works such as coluin fottings, column pedestals , plinth beams , grade beams staircase steps, bed block etc. which require only nominal strutting using mild steel sheets of size 90cm x 60 cm and BG stiffened with wlelded mild steel angles of size 25mm x 25mm x 3mm for boarding, laid over silver oak joists of size 10cm x 6.50cm spaced at about 75cm centre to centre or at suitable intarvals etc., complete complyingwithstandard specification ( Payment for centering shall be given after the concrete is laid) for Road sides |
6 | Supplying fabricating and placing in position mild steel or ribbed for steel and all reinforced cement concrete works as per the design given includingcost of steel and binding wire in all floors etc., complete complying with standard specification. (The contractor will have to make his own arrangements for the supply of MS plain Rod / RTS rod and black binding wire) |
7 | Plain Cement Concrete 1:4:8 (One Cement, Four sand and Eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed , consolidated and curingetc. complete complying with standard specification |
8 | Plain Cement Concrete 1:2:4 (One Cement, Two sand and Four hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed , consolidated and curingetc. complete complying with standard specification |
9 | Plain Cement Concrete 1:1 1/2 :3 (one cement, ona and half sand and three hard broken stone jelly) using 40mm size hard broken granite stone jelly including cost and conveyance of materials is to site etc., complete complying with standard specification |
10 | Rainforce Cement Concrete 1:1 1/2 :3 (one cement, ona and half sand and three hard broken stone jelly) using 40mm size hard broken granite stone jelly including cost and conveyance of materials is to site etc., complete complying with standard specification |
11 | Hire charges for Diesel Engine 5 HP above including fuel cost, Operation and transportation of the eigine etc., complete for dewatering as per standard specification. |
12 | Hire charges for Diesel Engine 7.5 HP above including fuel cost, Operation and transportation of the eigine etc., complete for dewatering as per standard specification. |
13 | Supply and leak arresting bond (Entrap plug) 5 Kgs. contain bag including cost and conveyance of materials etc., complete as per ISI standard as directed by the departmental officers. |
14 | Jointing PSC pipes and specials with neat cement of cement mortar and spun yarn including caulking and testing to the required pressure (with water including cost of jointing materials) 600 mm PSC Pipe |
15 | Jointing PSC pipes and specials with neat cement of cement mortar and spun yarn including caulking and testing to the required pressure (with water including cost of jointing materials) 500 mm PSC Pipe |
16 | Jointing PSC pipes and specials with neat cement of cement mortar and spun yarn including caulking and testing to the required pressure (with water including cost of jointing materials) 450 mm PSC Pipe |
17 | Jointing PSC pipes and specials with neat cement of cement mortar and spun yarn including caulking and testing to the required pressure (with water including cost of jointing materials) 350 mm PSC Pipe |
18 | Supply and delivery of PVC Pipe, GI Pipes of best approved quality and make confirming to ISS of the following diameters and providing leak proof joints etc., including wherever necessary and redoing the disturbed porting to the original condition complete complying with standard specification (The PVC pipe and GI Pipes should be got approved from the Municipal Engineer before use on works)110mm PVC Pipe 6 Kg/Sq.cm. |
19 | Supply and delivery of PVC Pipe, GI Pipes of best approved quality and make confirming to ISS of the following diameters and providing leak proof joints etc., including wherever necessary and redoing the disturbed porting to the original condition complete complying with standard specification (The PVC pipe and GI Pipes should be got approved from the Municipal Engineer before use on works) 90mm PVC Pipe 6 Kg/Sq.cm. |
20 | Supply and delivery of PVC Pipe, GI Pipes of best approved quality and make confirming to ISS of the following diameters and providing leak proof joints etc., including wherever necessary and redoing the disturbed porting to the original condition complete complying with standard specification (The PVC pipe and GI Pipes should be got approved from the Municipal Engineer before use on works) 100mm GI Pipe |
21 | Supply and delivery of PVC Pipe, GI Pipes of best approved quality and make confirming to ISS of the following diameters and providing leak proof joints etc., including wherever necessary and redoing the disturbed porting to the original condition complete complying with standard specification (The PVC pipe and GI Pipes should be got approved from the Municipal Engineer before use on works)80mm GI Pipe |
22 | Cutting PVC rigid pipes and specials true to axis and finishing the ends complete as per standard as directed by the departmental officers. 110mm PVC Pipe 6 Kg/Sq.cm. |
23 | Cutting PVC rigid pipes and specials true to axis and finishing the ends complete as per standard as directed by the departmental officers. 90mm PVC Pipe 6 Kg/Sq.cm. |
24 | Lowing 90mm PVC rigid pipes and specials to trench any laying to proper grade and alignment jointing with PVC couplers with cement paste and testing to the required pressure including conveyance of water for filling during testing etc., complete complying with standard specification. |
25 | Supplying and fixing position of the following PVC & GI specials best approved quality confirming to ISS and providing leak proof joints with PVC adhesive etc., and giving connections to the PVC pipe etc., complete complying with standard specifications. (The PVC and GI specials should be got approved from the Municipal Engineer before use on works)90mm PVC End cup |
26 | 90mm PVC Bend |
27 | 90mm PVC Coupler |
28 | 90mm PVC Tee |
29 | 110mm PVC End cup |
30 | 110mm PVC Bend |
31 | 110mm PVC Coupler |
32 | 110mm PVC Tee |
33 | 140mm PVC End cup |
34 | 140mm PVC Bend |
35 | 140mm PVC Coupler |
36 | 140mm PVC Tee |
37 | 160mm PVC End cup |
38 | 160mm PVC Bend |
39 | 160mm PVC Coupler |
40 | 160mm PVC Tee |
41 | 100mm GI Flange set |
42 | 100mm GI Coupling |
43 | 100mm GI Pipe Niple 0.5m Length |
44 | 100mm GI Bend |
45 | 100mm GI Tee |
46 | 80mm GI Coupling |
47 | 80mm GI Flange set |
48 | 80mm GI Pipe Niple 0.5m |
49 | 80mm GI Bend |
50 | 80mm GI Tee |
51 | Supplying and Delivery of the following AC Pipes of Class 15 as per IS 1592/2003 best approved quality confirming to ISS of the following diameters etc., including wherever necessary and redoing disturbed portion to the original condition complete complying with standard specifications. (The AC Pipes should be got approved from the Municipal Engineer before use on works) 100mm dia AC Pipe Class 15 |
52 | 125mm dia AC Pipe Class 15 |
53 | 150mm dia AC Pipe Class 15 |
54 | 200mm dia AC Pipe Class 15 |
55 | Supplying and Delivery of AC collar of Class 15 as per IS 1592/2003 best approved quality confirming to ISS of the following diameters etc., including wherever necessary and redoing disturbed portion to the original condition complete complying with standard specifications. (The AC Pipes should be got approved from the Municipal Engineer before use on works) 100mm dia AC Collar Class 15 |
56 | 125mm dia AC Collar Class 15 |
57 | 150mm dia AC Collar Class 15 |
58 | 200mm dia AC Collar Class 15 |
59 | Supply and fabrication of MS Collar to the size of 450mm x 6mm thick including the cost of materials fabrication, transporting and labour charges etc., complete. 3.14x0.45x1.5x0.006=0.0127x7850Kg/cum=99.70 Kg. |
60 | Lowing AC Pipes and speicials in the trench carefully, laying to proper grade and alignment jointing of AC Pipes with simplex joints with ribber rings or with CI detachable joints or with MS couplers and testing to the required pressure including conveyance of water for filling during testing. a) 100mm dia AC Pipe Class 15 |
61 | b) 125mm dia AC Pipe Class 15 |
62 | c) 150mm dia AC Pipe Class 15 |
63 | Cutting true to axis and finishing the ends complete as per standards as directed by the departmental officers. 100mm dia AC Pipe Class 15 |
64 | b) 125mm dia AC Pipe Class 15 |
65 | c) 150mm dia AC Pipe Class 15 |
66 | Removing the burst CI pipe line and removal of slushy soil and baling out water and replacing the pipeline with sound pipe including jointing and cost of refilling the pipeline with water for retesting the pipe line etc., complete (Excluding cost of sound pipe and jointing materials and earth work) and as directed by TWAD board officers. 350mm dia CI Pipe |
67 | Removing the burst CI pipe line and removal of slushy soil and baling out water and replacing the pipeline with sound pipe including jointing and cost of refilling the pipeline with water for retesting the pipe line etc., complete (Excluding cost of sound pipe and jointing materials and earth work) and as directed by TWAD board officers.400mm dia CI Pipe |
68 | Removing the burst AC pipe line and removal of slushy soil and baling out water and replacing the pipeline with sound pipe including jointing and cost of refilling the pipeline with water for retesting the pipe line etc., complete (Excluding cost of sound pipe and jointing materials and earth work) and as directed by TWAD board officers.400mm dia AC Pipe |
69 | 450mm dia AC Pipe |
70 | 500mm dia AC Pipe |
71 | 600mm dia AC Pipe |
72 | Removing the burst PVC pipe line and removal of slushy soil and baling out water and replacing the pipeline with sound pipe including jointing and cost of refilling the pipeline with water for retesting the pipe line etc., complete (Excluding cost of sound pipe and jointing materials and earth work) and as directed by TWAD board officers.a) 110mm PVC Pipe (6 Kg / CM2) |
73 | b) 90mm PVC Pipe (6 Kg / CM2 |
74 | Jointing the C.I.S/S Pipe and specials with neat cement or cement mortar and spun yarn including caulking the joints curing and testing to the required pressure with water (including cost of jointing materials) 100mm dia C.I. S/S Pipes and specials |
75 | 125mm dia C.I. S/S Pipes and specials |
76 | 150mm dia C.I. S/S Pipes and specials |
77 | 200mm dia C.I. S/S Pipes and specials |
78 | 400mm dia C.I. S/S Pipes and specials |
79 | 350mm dia C.I. S/S Pipes and specials |
80 | 450mm dia C.I. S/S Pipes and specials |
81 | 600mm dia C.I. S/S Pipes and specials |
82 | Lights Arrangements (Manitance Works) With Genset:Hire Charges for Portable Genset 1.00 KVA with 2 Nos. of 150W flood light including all Incidential Charges, Transportation Crew Charges and fuel Charges Etc., Complete. |
83 | Hire Charges for develpying earth moving machinery (Jcb/Polclain) for earthwork including cost of fuel and operation charges etc., complete as per standard specification as directed by the departmental officers. a) Jcb |
84 | b) poclain |
85 | Engaging Heavy Air Compressor concrete braker for braking concrete portion on hire basis including cost of fuel and operation charges etc., complete as per standard specification as directed by the departmental officers. |
86 | Refilling the trenches with suitable excavated earth available along the alignement after the pipes & specials are laid, jointed & tested in layers & watering ramming & consolidation etc., completed as per standard as directed by the departmental officers. |
87 | Supply and delivery ofthe following size of CID Joint of approved quality with Excise dutyetccomplete as per standard specification and as directed by Departmental Engineer. 5" C.I.D. Joint |
88 | 6" C.I.D. Joint |
89 | 8" C.I.D. Joint |
90 | 10" C.I.D. Joint |
91 | 12" C.I.D. Joint |
92 | Supplying and delivery ofFollowingSize of CI D/F sluice valves with Cap / Wheel as per IS:14846/ 2000PN 1.0with ISI markingcomplete as per standard specification and as directed by Departmental Engineer.8" Sluice Valve- Heavy ISI -200mm |
93 | 10" Sluice Valve - Heavy ISI -250mm |
94 | 12" Sluice Valve - Heavy ISI - 300mm |
95 | 14" Sluice Valve- Heavy ISI -350mm |
96 | 16" Sluice Valve - Heavy ISI - 400mm |
97 | 18" Sluice Valve - Heavy ISI -450mm |
98 | 20" Sluice Valve - Heavy ISI-500mm |
99 | 24" Sluice Valve - Heavy ISI -600mm |
100 | Supply fo Sluice Valve Gun Metal Bar |
101 | Supply and delivery of C.I. DOUBLE AIR VALVE AS PER ISI 14845/2000 following sizes 100mm Double Air valve |
102 | 150mm Double Air valve |
103 | 200mm Double air valve |
104 | Supply of Sluice Valve SS Rod |
105 | Supply of Sluice Valve GM Rod |
106 | Removal, recondition and refixing 6" Sluice Valve Reconditioning Charges |
107 | Removal, recondition and refixing 8" Sluice Valve Reconditioning Charges |
108 | Removal, recondition and refixing 10" Sluice Valve Reconditioning Charges |
109 | Removal, recondition and refixing 12" Sluice Valve Reconditioning Charges |
110 | Removal, recondition and refixing 14" Sluice Valve Reconditioning Charges |
111 | 5" Sluice Valve shaftand Check Nut Replacement work |
112 | 6" Sluice Valve shaftand Check Nut Replacement work |
113 | 8" Sluice Valve shaftand Check Nut Replacement work |
114 | 10" Sluice Valve shaftand Check Nut Replacement work |
115 | 12" Sluice Valve shaftand Check Nut Replacement work |
116 | 14" Sluice Valve shaftand Check Nut Replacement work |
117 | Supply and delivery of Following 1.1 KV GradeArmouredAluminium conductor LTUG Cable confirming to IS 1554 PART I with ISI marking70 Sq. mm 31/2 core |
118 | 95 Sq. mm 31/2 core |
119 | 120 Sq. mm 31/2 core |
120 | 150 Sq. mm 31/2 core |
121 | Flushing of bore wells using 360 CFT Compressure as per Standard and as directed by the dept. officers. |
122 | Labor charges for Desalting light or sandy soil from the sump below including the charges for special tools & plant and air compressor etc., complete. a) 20,00,000 liter capacity OHT |
123 | b) 10,00,000 liter capacity OHT |
124 | c) 8,50,000 liter capacity OHT |
125 | d) 5,00,000 liter capacity OHT |
126 | e) 2,00,000 liter capacity OHT |
127 | f) 1,00,000 liter capacity OHT |
128 | Supplying and Delivery of DUCTILE IRON SOCKET/ SPIGOT PIPES FOR CLASS K7 AS PER IS 8329/2000best approved quality confirming to ISS of the following diameters etc., including wherever necessary and redoing disturbed portion to the original condition complete complying with standard specifications. (The AC Pipes should be got approved from the Municipal Engineer before use on works) 100 mmDI K7 Pipe. |
129 | 150 mmDI K7Pipe. |
130 | 200 mmDI K7 Pipe. |
131 | 250 mmDI K7 Pipe. |
132 | 300 mmDI K7 Pipe. |
133 | 350 mmDI K7 Pipe. |
134 | 400 mmDI K7 Pipe. |
135 | 450 mmDI K7 Pipe. |
136 | 500 mmDI K7 Pipe. |
137 | 601 mmDI K7 Pipe. |