Tender For Construction Of Community Toilet With Insatallation Of Water Supply Of Community Toilet At Near Nabin Sangha Club And At Ambari Bazar Within Rajganj Panchayet Samity
Tender Value
10.06 Lakhs
Estimated cost
Bid Submission
25 May 2023
0 days left
EMD
20130
Bank guarantee accepted
Document Fee
1510
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
binnaguri → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Community Toilet With Insatallation Of Water Supply Of Community Toilet At Near Nabin Sangha Club And At Ambari Bazar Within Rajganj Panchayet Samity
BOQ
| Sl. No. | Item Description |
| 1 | BUILDING WORKS :-Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone) including removing, spreading and stacking of soils within a lead of 75m.as directed. The item includes trimming the sides of trenches, leveling, and dressing and ramming the bottom, bailing out water etc. as required, complete.Depth of excavation not exceeding 1500mm. |
| 2 | Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 150 mm. including watering and ranmming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation |
| 3 | (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water,ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity). |
| 4 | Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches |
| 5 | Cement Concrete with graded stone (30 mm size) excluding shutteringIn ground floor and foundation.(a) 1:3:6 proportion |
| 6 | Brick work with 1st class bricks in cement mortar (1:4) in ground floor. In foundation & plinth |
| 7 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes.In Ground Floor :ii) River Bazree |
| 8 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at inter-section, complete as per drawing and direction.(a) For works in foundation, basement and upto roof of ground floor/upto 4 m. (i) Tor Steel/Mild SteelTATA/SAIL…..(in Ground Floor) |
| 9 | Hire and labour for shuttering with centering and necessary staging upto 4 m using approved stout and thick hard wood planks ……………. Fitting, fixing & striking out after completion of works (upto roof of groung floor)(b) With out staging in foundation and plinth. |
| 10 | (a) For Superstructure with staging. |
| 11 | 125 mm th. brick work with 1st class bricks in cement mortar (1:4) in ground floor.In Ground Floor : |
| 12 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) WallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m Coloured decorative |
| 13 | (A) FloorWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.b) Area of each tile above 0.09 Sq.m(i) Coloured decorativeIn Ground Floor |
| 14 | Plaster (to wall, floor, celling etc.) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface]In Ground Floor :ii) With 1:4 cement mortera) 15 mm thick plaster |
| 15 | c) 10 mm thick plaster |
| 16 | Neat cement punning about 1.50 mm. th. in wall, dado, window, sills, floor, drain etc.NOTE : Cement 0.152 cu. M. per 100 sq. m. |
| 17 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction protecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc. including hoisting in position, straightening if required, fixing lugs locking bracket, handle plate etc, including hosting in position, straightening if required, fixing lugs in cement concrete (1:2:4) with stone chips 20 mm down cuttings holes and mending good damages to match with existing surface complete in all respect excluding glazing.i) In Ground Floor:Flash butt welded windows and ventilatorsb) Openable steel windows as per IS sizes with side hung shutters and horizontal glazing bars with/without fixed type ventilators. |
| 18 | Supplying 1.5 mm thick MS sheet fitted & fixed on one or both faces of MS / WI gate etc with point weilding at not more than 150 mm apart complite….. Materials.In Ground Floor : |
| 19 | Supplying Fitting & fixing Factory made Pre - laminated P.V.C. door frame of size 50 mm. X 47 mm with a wall thickness of 5 mm. made out of extruded 5 mm. Pre - laminated P.V.C sheet cut at two corners and joined with two No. of 1.5 mm. long brackets of 15 mm X 15 mm. M.S. Square tube. The two vertical door profiles are to be re inforced with 19 mm X 19 mm. M.S. Square tube of 19 gauge, weather seal to be provided through out the frame. The door frame shall be fixed with the wall using 65 / 100 mm M.S Screws through the frame by using P.V.C. fasteners. A minimum of 4 Nos. of screws to be provided for each vertical members and minimum 2 Nos for horizontal members etc. complete as per Manufacturer\"s specification and direction of the Engineer - in - Charge. |
| 20 | Supplying,Fitting & Fixing 30 mm thick both side pre laminated Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S.tubes of 19 gauge thickness and size 19 mm x 19 mm for styles, top and bottom rails, M.S. frame shall have cost of stee lprimers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of which 50 mmshall be flatand 20 mm shall be tapered in 45 degree angle on either sides formingstyles; and 5 mm th .95 mm wide PVC sheet out of which 75 mm shall be flatand 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sidesto form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5mm x 2) th., 20 mm wide cross PVC sheet as gap insert for top rail and bottom rail sheet to be fitted in the M.S. frame welded / sealed to the styles &rails with 7 mm (5mm + 2mm) th . x 15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. Anadditional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the \"C\" channel using PVC solventadhesive etc. complete excluding all necessary hardwires as per direction of Engineer - in - Charge. |
| 21 | Priming one coat on steel or other metal surface with synthetic oil bound prinmer of approved quality including smoothening surfaces by sand papering etc. |
| 22 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sandparpering etc. including using of approved putty etc. on the surface, if necessary.(b) On steel or other metal surface:With super gloss (hi-gloss)iv) Two coats(with any shade except white) |
| 23 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe & Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code.(i) For 10 usersB) With Bazree (N.B Varity) (Other than SAIL/TATA/RINL) |
| 24 | Applying decoretive cement based paint of approved quality after preparing the surface including scraping the same throughly (plastered or concrete surface) as per manufacturer\"s specification.iii) Two coats |
| 25 | SOLAR TUBEWELL WORKS :-Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore.(a) For depth upto 150 metre.(a) 50 mm. Dia Boring etc. |
| 26 | Supply of PVC pipes & fittings (midium duty) conforming to ASTMD - 1785 and threaded to match with GI pipes as per IS : 1239 (part-I) with all necessary accessories, specials viz. socket, bend,tee,union, cross, elbow, nipple, long screw, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payments will be made for accessories, specials. Payment for painting will be made seperately)(A) PVC pipes 40 mm dia |
| 27 | Supplying P.V.C- stainer of approved make with adaptor Conforming to IS - 12818 specification.(i) 40mm dia. |
| 28 | Supplying, fitting and fixing plug of approved make conforming to I.S. specifications.(i) 40 mm |
| 29 | Supplying, fitting and fixing Steel Cutter Piece upto 450 mm. long with sockets.(i) 40 mm |
| 30 | Module — 330 w p (48 volt) :a) The PV Module shall contain Poly Crystalline silicon solar cells and must have MNRE certifiedb) The power output of the modules under STC wouId be a minimum 330 WP at a voltage of 41 (+/-) 0.2 Vc) The open circuit voltage of the PV modulesunder STC wouldbe 48.7 Volts.d)The module efficiency wouid be 19.56%e)A bird spike shall be provided to avoidbird sitting on the solar module at the highest point ofthemodule structure.f)SPV module shall be highly reliable lightweightand shall be a service of life of more than 25 years. It shall have a limited power loss of not more ttianI 0% of normal output at the end of10 years and not more than 20% at the end of 25 years.g)The solar module shall be able to withstandthefollowing environmentat conditions normally encounteredat the site — rainfallof 40 mm, Humiditylevel up to 95%h)Strip must contain the folIowings — Manufecturer name, modelnumber,year of make. |
| 31 | Soler Pump Controller (VFD): Solar Pump Controller shall contain :a)HP(KW) :1 to SO HP (0.75 to 110 KW)b|DC InputV\"oltage : E50to 70a mdc +lawc)AC output Voltage :120to 4l5Vac.3Ød)Output Current : 3to 210 Rpm.e) Overload Current :150% For 60 Seconds, 200% For 1SecondI) ProtectiveMethod :IP 20. IP 54,TP 65 Enclosed Typeg)Output frequency \"Ito 400 HZh)MPPT Efficiency: 99.9 % Ambient Temperalute :- 10to +60° C |
| 32 | Solar Mono-Block Pump shall contain (0.5 HP)a)Voltage : 110 Voltb)Watt : 850Wc] Head (in meters) : 40 meterd)Discharge in LMP : 35 LMPe)Shut off Head :55 meterf)Overall Effjciency : 54.90 %g)Outer Dia. : 95mmh)MaximumAMP :6.5A Size OF Cable :2.5 sq. mm. |
| 33 | Solar Panel mtountingsructure:-M.S Structuralworks for solar panels on roof area connected to one another as per desing, direction of engineerin-charge complete include cuttingto requisite shape and Levitt, fabricationwiili necessarybolting,metal are welding conformingto IS: 8 I 6-1 956 &1995 using electrodes of approvedmae and brand conformingto IS :8 14-1957 , haulage,hoisting and erection all complete. |
| 34 | Wire, Cable Features, On-Off Auto ceser Device/ Floating Switch & Others:The newly release 1 500volt connectors arewith highest current rating among connectorsused PV DC application.It supports are cable range Upto 16 Sq-mmfor TUV and 6 AWGfor UL. With higher voltage. higher current, and wider cable range, out TUV/UL 1500/l000V series provide an optimal salution for customer to achive ”Balance Of System ”a) 1.5mm 3 core cable (For VFDto Mono - BlockPump -30 Mtr.b)6mm cable (Single Cole for Panel to VFD) - 16Mtr. |
| 35 | INSTALLATION:There are some major step to a Solar installationthat your choice Solar company will generally follow:i)Installationof Mono-Block Pumpii) Orderingequipmentiii)Solar panel installation. |
| 36 | Supplying, fitting and fixing Peet\"s valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).40 mm dia |
| 37 | 25 mm dia |
| 38 | Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only).40 mm dia |
| 39 | Supplying, fitting and fixing bib cock or stop cock(ii) Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand) |
| 40 | (b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar |
| 41 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately.a. 15 mm dia. |
| 42 | b. 20 mm dia. |
| 43 | c. 25 mm dia. |
| 44 | d. 32 mm dia. |
| 45 | e. 40 mm dia. |
| 46 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc |
| 47 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer. 1000 litre capacity |
| 48 | Labour for hoisting plastic water storage tank.ii) upto 1500 litre capacity. (a) Upto 1st story from G.L. |
| 49 | Labour for punching hole in plastic water storage tank upto 50 mm dia |
| 50 | Supplying, fitting & fixing approved patent vent cowl I.C.I. conforming to I.S.S and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will be paid seperately). 100 mm dia. |
| 51 | Supply of UPVC pipes (B Type) & fittings conforming to IS13592-1992 (A) (i) Single Socketed 3 Meter Length. 110mm dia. |
| 52 | b) Plain Y-Junction. 110 mm dia |
| 53 | Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately). (i) 450 mm X 350 mm |
| 54 | Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding \"P\" or \"S\" trap (excluding cost of concrete for fixing).530 mm x 410 mm |
| 55 | Supplying,fitting and fixing cast iron \"P\" or \"S\" trap conformimg to I.S. 3989 / 1970 and 1729 / 1964 including lead caulked joints and painting two coats to the exposed surface. (Painting to be paid seperately). (A) \"P\" Trap. (iii) 100 mm. |
| 56 | Painting block letters or digits in Black Japan or any approved paint as per direction.c) Size above 4 cm. and upto 5 cm. |
| 57 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stonechips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia.ii) (Other than SAIL/TATA/RINL) |
| 58 | Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials.ii) With Bazree (N.B Variety) (Other than SAIL/TATA/RINL) |
| 59 | Supplying fitting and fixing of Electrical accessories including electrical wiring ect all complete. (payment will be made as per current PWD Elect. Schedule of rates) |
| 60 | GST 18% |
| 61 | W.W. CESS 1% |
AI Tender Summary
Tender Timeline
May 12, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedMay 25, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMay 30, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender