| 1 | Surface dressing n exc 15 cm deep and getting out in Hard/dense soil complete all as specified and as directed. |
| 2 | Excavating over areas, n exc 1.5 m deep and getting out in Hard/dense soil complete all as specified and as directed. |
| 3 | Excavating over areas,exc 1.5 m deep but not exc 3.0m deep and getting out in Hard/dense soil complete all as specified and as directed. |
| 4 | M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate complete all as specified and as directed. |
| 5 | M&L for Formwork to sides rough finished surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 6 | M&L for RCC M25 Design Mix for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 7 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 8 | M&L for Mild steel bars5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed. |
| 9 | M&L for Mild SteelCompound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc complete all as specified and as directed. |
| 10 | M&L for Mild Steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and as directed. |
| 11 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 12 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. |
| 13 | M&L Pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm (TCT, AZ 150) of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 14 | M & L Preparation of new or previously untreated steel surfaces of any description over 10 cm in width or girth applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer, complete all as specified and as directed. |
| 15 | S& F Mild Steel Framed work such as in grills, gratings, etc. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe-290. Gde-E-165, etc complete all as specified and as directed. |
| 16 | M&L for dismantling stone slabs and tiles laid dry and pointed of any description or thickness in floors, aprons etc. complete all as specified and as directed. |
| 17 | M&L for 15mm thick screed bed or bedding layer of cement mortar 1:6 for laying floor finishes complete all as specified and as directed. |
| 18 | M & L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and as directed. |
| 19 | M&L preparation of old decorated wall surface and applying two coats of OBD over two coat of wall care putty, complete all as specified and as directed. |
| 20 | S&F LED Flood light fitting 50 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP66 protection and impact resistance of IK07 with 10 KVBuilt-in-Surge Protection Device,road way light fitting with high power LED as light source of capacity 50 watts with suitable drivers etc and connecting with 1.5 Sqmm copperconductor PVC insulated three core weather proof cable etc, fixing to wall/pole, complete incl fixing with clamps, nuts , bolt etc. all as specified and as directed. |
| 21 | Supply & lay heavy duty PVC insulated multi stranded Aluminum conductor 3 core of size 4.0 Sqmm, 230 volts, 50 HZ with 20mm PVC pipe for protection incl clamping etc complete all as specified and as directed. |
| 22 | Taking out and Relaying of LT cable of size 10sq mm to 50 Sqmm 2/3.5 coreafter carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugsall as specified and as directed. Note: Earth work , sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevant Item. |
| 23 | M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 10 mm x 2 core laid in trenches / duct or fixed to wall / passing through pipe on pole with suitable size cable glands, crimping type cable lugs for stranded aluminium conductor complete all as specified and as directed. |
| 24 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in hard / densesoil complete all as specified and as directed. |
| 25 | Spreading riddled earth ( after preparation of excavated earth) inCable duct forcushioning of cable laid in trenches complete all as specified and as directed. Note:- Punned thickness 18 CM (6.25 Cm below cable and 11.75 cm above cable)will be measured for payment purpose. The earth removed during excavation to be used as riddled earth after crushing and sieving. Quoted rate is deemed to be inclusive of all arrangement as mentioned. |
| 26 | M&L brick protection with common burnt brick sub class ‘B’ of size 230x115x75mm for cable protection complete all as specified and asdirected. |
| 27 | Dismantling LT steel tubular pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009 and applying two coats of aluminium paint to pole surface complete all as specified and asdirected. |
| 28 | S & F hot press moulded SMC junction / terminal box of size with internal dimensions of 200 x 140 x 95 mm with hinged door, including provision of 2 way connector415 Volts made out of polycarbonate or Bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or outgoing cables by providing suitable of size of cable lugs/glands, fixed on pole by means of clamps made out of MS flat iron of size 25 mm x 3 mm including dismantling of old unserviceable all as specified and as directed. |
| 29 | Supply and fixing of automatic street light switch using infrared sensor based nature switch for automatic switching of street lights. Nature switch operation should be based on natural light lux level. Required luminance level for switching on is < 30 Lux and for switching off >10 lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs. The sensor along with suitable power contactors incoming outgoing MCBS SP and auto manual (sensor bypass selection option should be enclosed in a pole /wall mountable enclosure made of rust proof electric shock proof termite proof and FR grade SMC Box conforming to IP54 single phase load of 8 KW with circuit wiringmin 10 sq mm copper wire 63 Ampscontactor and suitable MCBs atboth positions at incoming and out goings of breaking capacity 10 KA complete including necessary clamp (2 sets) for fixing on pole / wallcompleteincluding taking down old one all as specified and as directed. |