| 1 | BOQ ( Sch \"A\")Taking down carefullyaluminium/copper wiring of any size (for light, fan, socket or power etc complete) including fixture and fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights, bells etc and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and as directed.. |
| 2 | Supply & Fixing point wiring for one light point/ fan point controlled by one, one way switch with 1.5Sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLS)PVC cable drawn into & including PVC casing/capping and accessories including sunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.5 Sqmm multistrandedcopper conductor (FRLS) cable earth wire and connected to earth, etc and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed (Note:- wiring shall be done in colour coding as directed by Engineer in charge) |
| 3 | All as per item No.02 above but one bellpoint controlled by one switch |
| 4 | All as per item No.02 above but one light point controlled by one two way switch |
| 5 | All as per item No.02 above but one socket outlet 5 Amps on the same board. |
| 6 | All as per item No.02 above but one socket outlet 5 Amps on independent board |
| 7 | All as per item No 02 above but wiringwith 2.5sqmm copper wire (FRLS) PVCand 2.5 sqmm earth (FRLS) wire forsocket outlet 5 pin 15 amps on independent board. |
| 8 | All as per item No 02 here in before but wiringwith 4.0sqmm copper wire (FRLS) PVCand 4.0 sqmm earth wire (FRLS) forsocket outlet 5 pin 15 amps on independent board. |
| 9 | Supply & Fixing point wiring for one light point/ fan point controlled by one, one way switch with 1.5Sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLS)PVC cable drawn into & including medium grade PVC conduit (not less than 20mmouter dia) with all fittings and accessories fixed concealed(including chase cutting in brick/ stone masonry walls for fixing conduit and plastering and whitewash/colouring the external surface and matching the same with existing surface) andsunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washersincluding one continuous run of PVC insulated (green colour) 1.5 Sqmm multistrandedcopper conductor cable (FRLS)earth wire and connected to earth etc and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed (Note:- wiring shall be done in colour coding as directed by Engineer in charge.) |
| 10 | All as per item No.09 above but one bellpoint controlled by one switch. |
| 11 | All as per item No.09 above but one light point controlled by one two way switch. |
| 12 | All as per item No.09 above but one socket outlet 5 Amps on the same board. |
| 13 | All as per item No.09 above but one socket outlet 5 Amps on independent board |
| 14 | All as per item No 09 above but wiringwith 2.5 sqmm copper wire (FRLS) PVCand 1.5 sqmm earth wire (FRLS) cable forsocket outlet 5 pin 15 amps on independent board. |
| 15 | All as per item No 09 here-in-beforebut wiringwith 4.0 sqmm copper wire (FRLS) PVCand 4.0 sqmm earth wire (FRLS) cable forsocket outlet 5 pin 15 amps on independent board. |
| 16 | Supply & Fixing lamp holder (dome type) PVC insulated body with cord grip cap for angle/battern fitting complete all as specified and directed. |
| 17 | Suppy & Fixing switch piano flush type single pole, one way 6 Amp complete all as specified and directed. |
| 18 | Supply & Fixing switch piano, flush type single pole 15 Amp complete all as specified and directed. |
| 19 | Suppy & Fixing switch piano flush type single pole, two way 6 Amp complete all as specified and directed. |
| 20 | Supply & Fixing socket outlet 2 in 1, 3 pin, 6 Amp and 16 Amp flush type complete all as specified and directed. |
| 21 | Supply & Fixing socket outlet 2 in 1, 3 pin, 6 Amp flush type complete all as specified and directed. |
| 22 | Supply & Fixing Bell push, flush type, 6 Amp complete all as specified and directed. |
| 23 | Supply & Fixing steped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed. |
| 24 | Supply & fixing BellAC 230 volts, 50 Hz single pole complete all as specified and directed. |
| 25 | Supply & Fixing ceiling rose, PVC/ Poly carbonate, isolated body three terminal complete all as specified and directed. |
| 26 | Supply and fixing of 6 Amp one way switch, 1 module, modular type ,white polycarbonate,switches, sockets, fan regulator suitable for250V, AC, 50Hz. electrical supplycomplete all as specified and directed. |
| 27 | All as per item No.26 above but 6 Amp two way switch, 1 module |
| 28 | All as per item No. 26 above but 6 Amp 2/3 Pin combined socket shuttered, 2 module |
| 29 | All as per item No. 26 above but Modular Switch 1 way 16 Amp, 1 Module |
| 30 | All as per item No. 26 above but Modular socket 6A/16Amp, 2/3 pin combined, 2 Module |
| 31 | All as per item No.26 above but6 Ampbell push switch modular type |
| 32 | All as per item No. 26 above but Steped type electronic fan regulator modular, 120W-2 module |
| 33 | Supply and fixing of modular front plates, 2 Module white with frame on existing boxes complete as required complete all as specified and directed. |
| 34 | All as per item No. 33 above but 3 Module |
| 35 | All as per item No. 33 above but 4 Module |
| 36 | All as per item No.33 above but 6 Module |
| 37 | All as per item No. 33 above but 8 Module |
| 38 | Supply and fixing anodised rust proof 18 SWG MS box, flush type(1-2 Module) (to be of same make as modular switches and sockets)to berecessed in wall/gypsum partition complete as required complete all as specified and directed. |
| 39 | All as per item No. 38 above but (3 Module) |
| 40 | All as per item No. 38 above but (4 Module) |
| 41 | All as per item No. 38 above but (6-8 Module) |
| 42 | Supply & Fixingsheet metal enclosure with socket plug top and MCBs Single pole and neutral enclosure 240 Volt with a two pin and earth plug and socket complete with on single pole MCB 20 Amp complete including taking down unserviceable sheet metal enclosure of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour wash complete all as specified and directed. |
| 43 | Supply & Fixingsheet metal enclosure for DBs(double door type)single pole and neutral 4 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed including taking down unserviceable main switches MCB DB’s of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour wash complete all as specified and directed. |
| 44 | All as per item No. 43 above but 8 way |
| 45 | All as per item No. 43 above but 12 way |
| 46 | Supply & Fixingsheet metal enclosure for DBs(double door type)Triple pole and neutral 4 way including blanking plate as required with 200 Amps rated bus bar, 415 volts fixed and concealed in wall including taking down unserviceable main switches MCB DB’s of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour wash complete all as specified and directed. |
| 47 | All as per item No. 46 above but 6 way |
| 48 | M&L for PVC/Polycarbonate rectangular block for mounting, switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100mm x 100 mm and 50 mm deepincl fixed with screws and cup washers and taking down unserviceable switch board of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour wash complete all as specified and directed. |
| 49 | All as per item No. 48 above but 175 x 100 x 50 mm deep |
| 50 | All as per item No. 48 above but 200 x 150 x 50 mm deep |
| 51 | All as per item No. 48 above but 250 x 200 x 50 mm deep |
| 52 | Supplied & Fixing Rigid non matallic PVC conduits external dia 20 mm ISI marked exclusive of boxes (Junction/terminal) but inclusive of all tee, bends, elbows, reducers, bell mounth tube ends and fixing accessories such as couplers, lock, nuts, saddles, pipe hooks etc for exiting point/main/sub-main wiring complete all as specified and directed. |
| 53 | Supply & Fixing 240V, 10KA \"B\" curve miniature circuit breaker (MCB) of single pole and current carrying capacity 5 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed . |
| 54 | Supply & Fixing 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of single pole neutral (SPN) and current carrying capacity 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed . |
| 55 | Supply & Fixing 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of single pole neutral (SPN) and current carrying capacity 40 to 63 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed . |
| 56 | Supply & Fixing 415V, 10KA \"B\" curve miniature circuit breaker (MCB) of triple pole neutral/four pole (TPN/FP) and current carrying capacity 40 to 100 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed . |
| 57 | Material and labour for Sub main wiring with 2 run of 2.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and multi stranded copper conductor cable ISI marked, drawn in to and including Rigid non metallic PVC conduit ( ISI marked) Heavy grade, 20 mm dia (external) inclusive ofjunction/terminal boxes, all fittings and accessories fixed concealed with and including 1.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and multi stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DBincluding chase cutting and making good surface as original by plastering and white/ colour wash/ distempering etc including taking down existingold sub main wiring complete all as specified.Note :1 The cost of earth wire is included in the quoted rates. 2.Two run of 2.5 sqmm sub main wireand one run of 1.5 Sqmm copper conductor cable as earth wire applicable incl PVC conduit will be measured as one unit ie one running metre” |
| 58 | All as per item No. 57 above but2 X 4 Sqmm inclusive 4 Sqmm earth wire.Note :1 The cost of earth wire is included in the quoted rates. 2.Two run of 4 sqmm of sub main wire and one run of 4 Sqmm copper conductor cable as earth wire applicable incl PVC conduit will be measured as one unit ie one running metre” |
| 59 | All as per item No 57 above but 2 X 6 Sqmm inclusive 6 Sqmm earth wire.Note :1 The cost of earth wire is included in the quoted rates. 2.Two run of 6 sqmm of sub main wire and one run of 6 Sqmm copper conductor cable as earth wire applicable incl PVC conduit will be measured as one unit ie one running metre” |
| 60 | All as per item No. 57 here in before but 2 X 10Sqmm inclusive 10 Sqmm earth wire.Note :1 The cost of earth wire is included in the quoted rates. 2.Two run of 10 sqmm of sub main wire and one run of 10 Sqmm copper conductor cable as earth wire applicable incl PVC conduit will be measured as one unit ie one running metre” |
| 61 | Material and labour for Sub main wiring with 2 run of 2.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and multi stranded copper conductor cable ISI marked, drawn in and including PVC casing capping ( ISI marked) Heavy grade inclusive ofjunction/terminal boxes, all fittings and accessories fixed and including 1.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and multi stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DBincluding cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc including taking down existingold sub main wiring complete all as specified.Note :1 The cost of earth wire is included in the quoted rates. 2.Two run of 2.5 sqmm and one run of 1.5 Sqmm as applicable including PVC casing capping will be measured as one unit ie one running metre” |
| 62 | All as per item No. 61 above but 2 X 4 Sqmm inclusive 4 Sqmm earth wire.Note :1 The cost of earth wire is included in the quoted rates. 2.Two run of 4 sqmm and one run of 4 Sqmm as applicable including PVC casing capping will be measured as one unit ie one running metre” |
| 63 | All as per item No. 61 above but 2 X 6 Sqmm inclusive 6 Sqmm earth wire.Note :1 The cost of earth wire is included in the quoted rates. 2.Two run of 6 sqmm and one run of 6 Sqmm as applicable including PVC casing capping will be measured as one unit ie one running metre” |
| 64 | Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt, 220 V, AC, recessed type (warm/milky white as required on site) with high efficiency PMMAdiffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling, life of tube light not less than 50,000 hours including connecting up with driver three core flexible copper conductor cable of suitable size complete.Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher. |
| 65 | Supply and fixing round shape 15 watt, 220 V, AC, recessed type (warm/milky white as required on site)with high efficiency PMMAdiffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling, life of tube light not less than 50,000 hours including connecting up with driver three core flexible copper conductor cable of suitable size complete.Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher. |
| 66 | S & F LED light fitting 1X10 W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. Make : Havells cat pat HEXAFT10WLED857SSYMBOPC or equivalent cat part in Make :- Phillips/Bajaj/C&S Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher. |
| 67 | Supply and fixing post top lantern LED type 20 Watt, 230volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed . |
| 68 | Supply and fixing post top lantern LED type 40 Watt, 230volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed . |
| 69 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V, AC, decorative type with driver holder and LED lamp including connecting up with three core flexible copper cable of suitable size complete all as specified and directed . |
| 70 | Supply and fixing LED lights T-5 fitting 1x 20W (warm/milky white as required on site), 220V, AC with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose 1.5 RM and life of tube light not less than 50,000 hours completeall as specified and directed..Note:- Contractor shall submit 2 year warrenty of LED light fittings from manufracturer alongwith purchase voucher. |
| 71 | M&L for taking down ceiling fans / wall mounted fans of any size / sweep after disconnecting the wire from existing ceiling rose and refixing the same after painting the same with synthetic enamel paint by spray machine including filter after cleaning dust, taking out burnt/damaged winding, bushes & cleanig of stator androtor incl etc. Rewinding with 26/27 SWG of enamelled copper winding wire replacement of bearing /bushes, condencer2.5/4 mfd handing and testing of fan with and including provision of 23/0.0076 copper flexible twin core not less than 1.5 meter in length and making the fan operational with a guarantee period of one year after installing, repair of fan complete all as specified and directed. |
| 72 | Material & Labour for taking out burnt/damaged winding, bushes & cleaning of stator androtor incl etc ofexhaust fans any sweep and size, Rewinding with 26/27 SWG of enamelled copper winding wire replacement of shaft, bearing /bushes, condencer2.5/4 mfd handing and testing of fan with and including provision of 23/0.0076 copper flexibletwin core not less than 1.5 meter in length complete all as specified and directed. |
| 73 | M&L for taking out burnt/damaged fan motor of Desert cooler and supply and fixing new fan motor with 26/27 SWG of enameled copper winding wire with bearing / bushes and including provision of 23/0.0076 copper flexible twin core not less than 3 meter in length with two pin top plug etc. and make the desert cooler in operational condition complete all as specified and directed. Comprising of the following works :- (i) Replacement of water pump including water pipe (Complete set). (ii) Replacement of Fan blade (PVC/Iron) as required on site. (iii) Replacement of desert cooler front grill (Fiber/Steel/Plastic as required) including switch, indicator and regulators. (iv) Checking & tightening the electrical connection (v) Replacement of wood wool (Grass Air cooler cooling pad) suitable of iron/Plastic body desert cooler (vi) Replacement of side grill (sets of 3) for holding wood wool/cooling pads. (vii) Replacement of fan condenser 3.15/4.0 mfd. |
| 74 | M&L for servicing of water heater (Geyser) upto 50 Ltr capacity of any make by cleaning sludge and slurry, calcium inside inner water storage tank and make the geyser in operational condition all as specified and directed by Engr-in-charge. Comprising of the following works :- (i) Rectifying water leakage in inner copper/iron storage tank by using welding (ii) Replacement of heating element upto 2000 Watt. (iii) Replacement of Thermostat of suitable size as required on site. (iv) Checking & tightening the electrical connection (v) Replacement of safety valve. (vi) Replacement of NRV (Non returning valve) of suitable size as required at site . |
| 75 | Supply and fixing solar heater tube suitable for fixing of Solar Water heater system (Executed tube collector based) on direct transferring of heat of capacity 250 to 500 LPD and make the system operational complete all as specified and directed. |
| 76 | S & F Exhaust fan mettalic body ISI mark, 300 mm size with blades, frame and louvers including cutting opening through brick/stone/PCC block wall, making of holes and grouting of suitable size of nut and bolts for 300 mm exhaust fan and making good dismantling portion and making connection with wire of suitable size and connected accessories complete all as specified and directed |
| 77 | S & F Exhaust fan made of sturdy Engineering plastic type ISI mark, copper winding of sweep 300 mm size complete with louvers including cutting opening through brick/stone/PCC block wall, making of holes and grouting of suitable size of nut and bolts for 300 mm exhaust fan and making good dismantling portion and making connection with wire of suitable size and connected accessories complete all as specified and directed |
| 78 | M&L for earthing complete with galvanized sheet earth plate electrodes 60x60x6.3 mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of plat not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 and including excavation and earth work, GI pipe light grade 15 mm bore for protection of GI wire from earth electrode to and including the earth test point of galvanized Iron/ steel of size 75x75x25mm, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia TMT bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering and connected to earth test point including brazing at all joints except at test point and testing complete all as specified and directed.Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost to Govt by the contractor. |
| 79 | Supply and fixing LED Security/Street light fittings 35 watt 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant inclding thermal management in multiple optics complete with IP 65/66 Protectionwith GI Pipe light gradebracket 1.2 mtr long 40 mm dia fixed to wall with suitable size 2 Nos MS Clamps including nuts, bolts and washers and making connection with using 1.5 sqmm pvc insulated multi standard copper conductor three single core complete all as specified and diredted. |
| 80 | Supply and fixing LED flood light 70 watt, 230 V AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and average life of flood light not less than 50000 hours, including clamps, nut, bolts, fixing in wall including 2 sqmm PVC twin core aluminium cable from conductor to street light not less 2.0 metre , testing to satisfaction of Engineer in chargecomplete all as specified and directed. |
| 81 | Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230v, 10-60amp, accuracy class-I 50Hz, confirming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH including suitable copper wireas requirement at site complete all as specified and directed. Note: Existing old meter will be deposited at MES store. |
| 82 | Supply and fix electronic meters temper proof LCD display with polycarbonate cover 3 phase, 415 Volts, 10-60amp, accuracy class-I 50Hz, confirming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH including suitable copper wireas requirement at site complete all as specified and directed. Note: Existing old meter will be deposited at MES store. |
| 83 | Supply and fix Ceiling fans, complete with three blade, down rod, accessories 230 V, 1200 mm sweep, with squirrel cage induction motor with 1.5 sqmm suitable copper wireas requirement at site complete all as specified and directed. |
| 84 | M&L Servicing of indoor and outdoor unit of split type/ window AC of 1.5/2.0/3.0 ton capacity of any make by air blowing, cleaning the filter in water and drying in sun, cleaning of drain tray and rectifing water leak, checking and tightning the electrical connection incl provide insulation material on cooling coil and heating coil etc complete all as specified and directed |
| 85 | Supply andRefilling Gas/refrigerant (CFC free)in AC 1.5 ton / 2 Ton complete all as specified and directed |
| 86 | Supply andRefilling gas/refrigerant in Refrigerator having capacity 165 to 315 ltr complete all as specified and directed |
| 87 | Supply andRefilling Gas charging in Water cooler of capacity upto 60/120 Ltr complete all as specified and directed. |
| 88 | Supply, fixing in repairs and commissioning of Compressor for window, 1.5 ton capacity Air Conditioner (AC) complete all as specified and directed. Make:LG/Hitachi/GMCC/emerson. |
| 89 | Supply, fixing in repairs and commissioning of Compressor for Split AC, 1.5 ton Capacity complete all as specified and directed Make:LG/Hitachi/GMCC/emerson. |
| 90 | Supply, fixing in repairs and commissioning of Compressor Split and window, AC 2 ton complete all as specified and directed Make:LG/Hitachi/GMCC/emerson |
| 91 | Supply, fixing in repairs and commissioning Refrigerator compressor of capacity 165 to 180 ltr complete all as specified and directed |
| 92 | Supply, fixing in repairs and commissioning Refrigerator compressor of capacity 210 to 315 ltrs complete all as specified and directed |
| 93 | Supply, fixing in repairs and commissioning Water cooler compressor of capacity 40/80 ltr complete all as specified and directed |
| 94 | Supply, fixing in repairs and commissioning Water cooler compressor of capacity 60/120 ltr complete all as specified and directed |
| 95 | Supply, fixing in repairs and commissioning of relay for split and window AC upto capacity 2 Ton complete all as specified and directed |
| 96 | Supply, fixing in repairs and commissioning of relay for Refrigerator upto 315 Ltr capacitycomplete all as specified and directed |
| 97 | Supply, fixing in repairs and commissioning of PCB for split/window AC including inverter Split ACupto 2 ton capacity complete all as specified and directed |
| 98 | Supply and fixing in repairs Electronic control PCB for refrigerator upto 315 Ltr capacity all as specified and directed |
| 99 | Supply and fixing in repairs Thermostat of window/split AC of any capacity complete all as specified and directed |
| 100 | Supply and fixing in repairs Thermostat of Refrigerator any capacity complete all as specified and directed |
| 101 | Supply and fixing in repairs Thermostat of Water cooler of any capacity complete all as specified and directed |
| 102 | Supply and fixing in repairs blade with motor Split/window AC of capacity 1.5 TR to 2 TR complete all as specified and directed by Engr-in-charge. |
| 103 | Supply and fixing in repairs Fan motor Water cooler of capacity upto 60/120 Ltr complete all as specified and directed |
| 104 | Supply and fixing in repairs swing motor for split AC of any capacity complete all as specified and directed |
| 105 | Supply and fixing in repairs cooling coil for Window/SplitAC for any capcity and size complete all as specified and directed |
| 106 | Supply and fixing in repairs heating coil/condenser coil for split/window AC 1.5 TR to 2 TR complete all as specified and directed |
| 107 | Supply and fixing in repairs Reverse valve of AC/Refrigerator/water cooler complete all as specified and directed |
| 108 | Supply, fixing in repairs and commissioning Condenser 50 mfd for Split/Window AC upto 2 Ton capacity complete all as specified and directed |
| 109 | Supply and fixing in repairs timer switch for refrigerator of any capacity complete all as specified and directed |
| 110 | Supply and fixing in repairs remote unit for split type ACof any model/sizeall as specified and directed |
| 111 | Supply and fixing in repairs Water cooler PVC pipe complete all as specified and directed |
| 112 | Supply and fixing in repairs Float valve 15 mm for water cooler 40 to 120 ltr capacity all as specified and directed |
| 113 | Supply and fixing in repairs Push tap for water cooler any size/capacity all as specified and directed |
| 114 | Supply and fixing Repair of voltage stabilizer of capacity 4/2/1 KVA, single phase, 230 V, AC, 50 Hz all as specified and directed |