Tender For Publication Of E-Tender Notice For Annual Maintenance Of 11 Kv/0.433 Kv Ht/Lt Network For The Year 2023-24 Falling Within The Jurisdiction Of Sub Division Zakura
Tender Value
12 Lakhs
Estimated cost
Bid Submission
30 May 2023
0 days left
EMD
24000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
zakura → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Publication Of E-Tender Notice For Annual Maintenance Of 11 Kv/0.433 Kv Ht/Lt Network For The Year 2023-24 Falling Within The Jurisdiction Of Sub Division Zakura
BOQ
| Sl. No. | Item Description |
| 1 | Installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at Site and erection of 630 KVA Distribution TransformerComplete Job (Note: Distribution Transformer shall be provided by KPDCL which is to be lifted fromDivisional stores at Khanyar) |
| 2 | Installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at Site and erection of 400 KVA Distribution Transformer (Note: Distribution Transformer shall be provided by KPDCL which is to be lifted fromDivisional stores at Khanyar) |
| 3 | Installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at Site and erection of 300KVA Distribution Transformer Complete Job (Note: Distribution Transformer shall be provided by KPDCL which is to be lifted fromDivisional stores at Khanyar) |
| 4 | Installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at Site and erection of 250 KVA Distribution Transformer (Note: Distribution Transformer shall be provided by KPDCL which is to be lifted fromDivisional stores at Khanyar) |
| 5 | Installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at Site and erection of 200 KVA Distribution TransformerComplete Job (Note: Distribution Transformer shall be provided by KPDCL which is to be lifted fromDivisional stores at Khanyar) |
| 6 | Installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at Site and erection of 100 KVA Distribution Transformer Complete Job (Note: Distribution Transformer shall be provided by KPDCL which is to be lifted fromDivisional stores at Khanyar) |
| 7 | Installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at Site and erection of 63 KVA Distribution Transformer Complete Job Complete Job (Note: Distribution Transformer shall be provided by KPDCL which is to be lifted fromDivisional stores at Khanyar) |
| 8 | Installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at Site and erection of 16/25 KVA Distribution Transformer Complete Job (Note: Distribution Transformer shall be provided by KPDCL which is to be lifted fromDivisional stores at Khanyar) |
| 9 | Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 11 Mtr. LongST Poles ( SP 56) with pit excavation (Note: The poles shall be provided by KPDCL which is to be lifted from Divisional stores at Khanyar ) |
| 10 | Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. LongST Poles SP 33) with pit excavation (Note: The poles shall be provided by KPDCLwhich is to be lifted from Divisional stores at Khanyar )) |
| 11 | Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. LongST Poles ( SP 15 with pit excavation(Note: The poles shall be provided by KPDCLwhich is to be lifted from Divisional stores at Khanyar) |
| 12 | Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of PCC Poles 8 mt long with pit excavation(Note: The poles shall be provided by KPDCLwhich is to be lifted from Divisional stores at Khanyar ). |
| 13 | Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of PCC Poles 9 mt long with pit excavation(Note: The poles shall be provided by KPDCLwhich is to be lifted from Divisional stores at Khanyar ). |
| 14 | Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of conductor including joints with PG clamps of required size (Note conductor to be provided byKPDCLwhich is to be lifted from Divisional stores at Khanyar ) ) 100 mm² ACSR (Dog) |
| 15 | Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of conductor including joints with PG clamps of required size (Note conductor to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar which is to be lifted from Divisional Stores at Khanyar) 50 mm² ACSR ( Rabbit) |
| 16 | Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of conductor including joints with PG clamps of required size (Note conductor to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar which is to be lifted from Divisional Stores at Khanyar) 30 mm² ACSR ( Weasel) |
| 17 | Supply and fixing of Earthing of 8/9Mtr Pole as per J1 RECStandard (GI Wire of 8 SWG, 115 turns) |
| 18 | Supply and fixing of Earthing of 8/9Mtr Pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 3.0 mtr long through GI Strip 25X3 MM as per relevant IS. |
| 19 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral Earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brick masonry with RCC slab cover. |
| 20 | Supply of paint and Paintingwith red oxide |
| 21 | Supply of paint and PaintingwithAl paint |
| 22 | Installation, testing and commissioning of 11 kV Heavy Duty Station type Link Set of Standard Makeas per relevant IS.Link set to be provided by the KPDCL which is to be lifted from Divisional stores at Khanyar ) |
| 23 | Installation, testing and commissioning of 11 kV GO AB Switch Station Type of Standard Make (200 Amp) as per relevant IS.(Note: Link set to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar |
| 24 | Installation, testing and commissioning of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type as per relevant IS.(Note: LA to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar |
| 25 | Installation, testing and commissioning of DO 11 kV Horn Gap Fuse Set 3 Phase 200A as per relevant IS.(Note: DO to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar . |
| 26 | Fixing of 11kV Polymeric composite Pin Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, Creepage distance 320mm(Note: PIN Insulator to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar. |
| 27 | Fixing of 11kV Porcelain Disc Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, Creepage distance 320mm(Note: Disc insulatorto be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar |
| 28 | Installation, testing and commissioning of LT Shackle Insulator (Note:Shcakle to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar |
| 29 | Installation, testing and commissioning of LTmukki clamps(Note:mukki clamps to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar |
| 30 | Installation, testing and commissioning of LT D Clamp (Noted clamp to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar |
| 31 | Fixing of fabricated GI Angle/Channel/Flat/Pole Collars(Note: GI to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar |
| 32 | Fixing of Galvanised nuts and bolts(Note:Nuts and Bolts to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar |
| 33 | Installation, testing and commissioning of 35 mm² AB (HT) Cable (3x35+1x70 mm²) XLPE(11 kV, 3C +Earth) (Note: Cable to be provided by KPDCL which is to be lifted from Divisional stores at Khanyar ) |
| 34 | Installation, testing and commissioning of 35 mm² AB (HT) Cable (3x35+1x35mm²) XLPE(11 kV, 3C +Earth) (Note: Cable to be provided by KPDCL which is to be lifted from Divisional stores at Khanyar ) |
| 35 | Installation, testing and commissioning of 50 mm² AB (HT) Cable (3x50+1x70 mm²) XLPE(11 kV, 3C +Earth)(Note: Cable to be provided by KPDCL which is to be lifted from Divisional stores at Khanyar ) |
| 36 | Installation, testing and commissioning of 70 mm² AB (HT) Cable (3x70+1x95 mm²) XLPE(11 kV, 3C +Earth)(Note: Cable to be provided by KPDCLwhich is to be lifted from Divisional stores at Khanyar ) |
| 37 | Installation, testing and commissioning of 120 mm² AB (HT) Cable (3x120+1x95 mm²) XLPE(11 kV, 3C +Earth)(Note: Cable to be provided by KPDCL which is to be lifted from Divisional stores at Khanyar ) |
| 38 | Installation, testing and commissioning of 35 mm² AB (HT) Cable Kitoutdoor termination[Raychem/3M](Note: Kit to be provided by KPDCLwhich is to be lifted from Divisional stores at Khanyar ) |
| 39 | Installation, testing and commissioning of 50 mm² AB (HT) Cable kitoutdoor termination [Raychem/3M](Note: Kit to be provided by KPDCL which is to be lifted from Divisional stores at Khanyar ) |
| 40 | Installation, testing and commissioning of 70 mm² AB (HT) Cable kitoutdoor termination [Raychem/3M](Note: Kit to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar |
| 41 | Installation, testing and commissioning of 120 mm² AB (HT) Cable kit outdoor termination[Raychem/3M](Note: Kit to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar |
| 42 | Installation, testing and commissioning of 35 mm² AB (HT) Cable outdoor jointing kit [Raychem/3M](Note: Kit to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar |
| 43 | Installation, testing and commissioning of 50 mm² AB (HT) Cable outdoorjointing kit [Raychem/3M] (Note: Kit to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar |
| 44 | Installation, testing and commissioning of 70 mm² AB (HT) Cable outdoorjointing kit [Raychem/3M](Note: Kit to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar |
| 45 | Installation, testing and commissioning of 120 mm² AB (HT) Cable outdoor jointing kit [Raychem/3M](Note: Kit to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar |
| 46 | Installation, testing and commissioning of 35 mm² AB (LT) Cable ( 3x35 + 1 x 16 + 1 x 25) mm² XLPE 1.1kV, 3+1 C, Al)(cable to be provided by department but to be lifted from Divisional stores khanyar ) |
| 47 | Installation, testing and commissioning of 50 mm² AB (LT) Cable ( 3x50 + 1 x 16 + 1 x 35) mm² XLPE (1.1kV, 3+1 C, Al)(cable to be provided by department but to be lifted from Divisional stores khanyar ) |
| 48 | Installation, testing and commissioning of 70 mm² AB (LT) Cable ( 3 x 70 + 1 x 16 + 1 x 50) mm² XLPE (1.1kV, 3+1 C, Al)(cable to be provided by department but to be lifted from Divisional stores khanyar ) |
| 49 | Installation, testing and commissioning of 120 mm² AB (LT) Cable ( 3 x 120 + 1 x 25 + 1 x 95) mm² XLPE (1.1kV, 3+1 C, Al) (cable to be provided by department but to be lifted from Divisional stores khanyar ) |
| 50 | Installation, testing and commissioningof 25mm sq LT PVC Single Core,1.1kV Grade, FRLS typewith proper thimbling, crimping and routing (Note: Cable to be provided by KPDCL |
| 51 | Installation, testing and commissioningof 35 mm sq LT PVC Single Core,1.1kV Grade, FRLS typewith proper thimbling, crimping and routing (Note: Cable to be provided by KPDCL |
| 52 | Installation, testing and commissioningof 50 mm sq LT PVC Single Core,1.1kV Grade, FRLS typewith proper thimbling, crimping and routing (Note: Cable to be provided by KPDCL |
| 53 | Installation, testing and commissioningof 70 mm sq LT PVC Single Core,1.1kV Grade, FRLS type with proper thimbling, crimping and routing (Note: Cable to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar |
| 54 | Installation, testing and commissioningof 185 mm sq LT PVC Single Core,1.1kV Grade, FRLS typewith proper thimbling, crimping and routing (Note: Cable to be provided by KPDCL |
| 55 | Installation, testing and commissioningof 240mm sq LT PVC Single Core,1.1kV Grade, FRLS type with proper thimbling, crimping and routing(Note: Cable to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar |
| 56 | Installation, testing and commissioningof 300 mm sq LT PVC Single Core,1.1kV Grade, FRLS type with proper thimbling, crimping and routing(Note: Cable to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar |
| 57 | Installation, testing and commissioningof 400 mm sq LT PVC Single Core,1.1kV Grade, FRLS typewith proper thimbling, crimping and routing (Note: Cable to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar |
| 58 | Installation, testing and commissioningof 630 mm sq LT PVC Single Core,1.1kV Grade, FRLS typewith proper thimbling, crimping and routing (Note: Cable to be provided by KPDCL which is to be lifted from Divisional Stores at Khanyar |
| 59 | Providing ,Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 11 Mtr. LongST Poles ( SP 56) with pit excavation |
| 60 | Provding,Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. LongST Poles SP 33) with pit excavation |
| 61 | Providing ,Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. LongST Poles ( SP 150 with pit excavation |
| 62 | Providing ,Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of8 mt long PCC Poleswith pit excavation |
| 63 | Providing ,Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of9 mt long PCC Poleswith pit excavation |
| 64 | Providing Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of 100 mm² ACSR (Dog) conductor including joints with PG clamps of required size |
| 65 | Providing, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of 50 mm² ACSR ( Rabbit) conductor including joints with PG clamps of required size |
| 66 | Providing ,Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of 30 mm² ACSR ( Weasel) conductor including joints with PG clamps of required size |
| 67 | Supply ,Installation, testing and commissioning of 11 kV Heavy Duty Station type Link Set of Standard Make (200 Amp) as per relevant IS. |
| 68 | Supply, Installation, testing and commissioning of 11 kV GO AB Switch Station Type of Standard Make (200 Amp) as per relevant IS. |
| 69 | Supply, Installation, testing and commissioning of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type as per relevant IS. |
| 70 | Supply, Installation, testing and commissioning of DO 11 kV Horn Gap Fuse Set 3 Phase 200A as per relevant IS. |
| 71 | Supply, Fixing of 11kV Polymeric composite Pin Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, Creepage distance 320mm |
| 72 | Supply ,Fixing of 11kV Porcelain Disc Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, Creepage distance 320mm |
| 73 | Supply, Installation, testing and commissioning of LT Shackle Insulator |
| 74 | Supply ,Installation, testing and commissioning of LTmukki clamps fabricated out of 50x 8 mm flat GI ( at least 2.5 Kg Each) |
| 75 | Supply, Installation, testing and commissioning of LT D Clamp fabricated out of 50 X8 mm Flat GI |
| 76 | Supply, Fixing of fabricated GI Angle/Channel/Flat/Pole Collarsof Sizes 100x50x50 x6mm,70x40x40 x6mm,40x40 x6mm,50x50 x6mm |
| 77 | Providing ,Fixing of Galvanised nuts withbolts and washers ( full thread /half thread) |
| 78 | Providing, Installation, testing and commissioning of 35 mm² AB (HT) Cable (3x35+1x70 mm²) XLPE(11 kV, 3C +Earth) |
| 79 | Providing, Installation, testing and commissioning of 35 mm² AB (HT) Cable (3x35+1x35 mm²) XLPE(11 kV, 3C +Earth) |
| 80 | Providing ,Installation, testing and commissioning of 50 mm² AB (HT) Cable (3x50+1x70 mm²) XLPE(11 kV, 3C +Earth) |
| 81 | Providing ,Installation, testing and commissioning of 70 mm² AB (HT) Cable (3x70+1x95 mm²) XLPE(11 kV, 3C ) |
| 82 | Providing ,Installation, testing and commissioning of 70 mm² AB (HT) Cable (3x70+1x95 mm²) XLPE(11 kV, 3C + Earth ) |
| 83 | Providing Installation, testing and commissioning of 120 mm² AB (HT) Cable (3x120+1x95 mm²) XLPE(11 kV, 3C +Earth) |
| 84 | Supply, Installation, testing and commissioning of 35 mm² AB (HT) Cable Kitoutdoor termination[Raychem/3M] |
| 85 | Supply, Installation, testing and commissioning of 50 mm² AB (HT) Cable kitoutdoor termination [Raychem/3M] |
| 86 | Supply, Installation, testing and commissioning of 70 mm² AB (HT) Cable kitoutdoor termination [Raychem/3M] |
| 87 | Providing ,Installation, testing and commissioning of 120 mm² AB (HT) Cable kit outdoor termination[Raychem/3M] |
| 88 | Providing Installation, testing and commissioning of 35 mm² AB (HT) Cable outdoor jointing kit [Raychem/3M] |
| 89 | Providing ,Installation, testing and commissioning of 50 mm² AB (HT) Cable outdoorjointing kit [Raychem/3M] |
| 90 | Providing ,Installation, testing and commissioning of 70 mm² AB (HT) Cable outdoorjointing kit [Raychem/3M] |
| 91 | Providing, Installation, testing and commissioning of 120 mm² AB (HT) Cable outdoor jointing kit [Raychem/3M] |
| 92 | Supply ,Installation, testing and commissioning of 35 mm² AB (LT) Cable ( 3x35 + 1 x 16 + 1 x 25) mm² XLPE 1.1kV, 3+1 C, Al) |
| 93 | Supply ,Installation, testing and commissioning of 50 mm² AB (LT) Cable ( 3x50 + 1 x 16 + 1 x 35) mm² XLPE (1.1kV, 3+1 C, Al) |
| 94 | Supply ,Installation, testing and commissioning of 70 mm² AB (LT) Cable ( 3 x 70 + 1 x 16 + 1 x 50) mm² XLPE (1.1kV, 3+1 C, Al) |
| 95 | supply, Installation, testing and commissioning of 120 mm² AB (LT) Cable ( 3 x 120 + 1 x 16 + 1 x70) mm² XLPE (1.1kV, 3+1 C, Al) |
| 96 | Supply, installation / Fixing of Danger Plates with clamps |
| 97 | Supply , installation/ Fixing of Anti-Climbing Device with Clamps |
| 98 | Supply, Installation ,testing and commissioning of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 )mm, nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 99 | Providing, Installation, testing and commissioningof 25mm sq LT PVC Single Core,1.1kV Grade, FRLS type with proper thimbling, crimping and routing . |
| 100 | Providing, Installation, testing and commissioningof 35mm sq LT PVC Single Core,1.1kV Grade, FRLS type with proper thimbling, crimping and routing . |
| 101 | Providing, Installation, testing and commissioningof 50mm sq LT PVC Single Core,1.1kV Grade, FRLS type with proper thimbling, crimping and routing . |
| 102 | Providing, Installation, testing and commissioningof 70 mm sq LT PVC Single Core,1.1kV Grade, FRLS type with proper thimbling, crimping and routing . |
| 103 | Providing ,Installation, testing and commissioningof 185 mm sq LT PVC Single Core,1.1kV Grade, FRLS typewith proper thimbling, crimping and routing |
| 104 | Providing ,Installation, testing and commissioningof 240 mm sq LT PVC Single Core,1.1kV Grade, FRLS type with proper thimbling, crimping and routing |
| 105 | Providing ,Installation, testing and commissioningof 400 mm sq LT PVC Single Core,1.1kV Grade, FRLS typewith proper thimbling, crimping and routing |
| 106 | Dismantling, Stackingof 8/9 mtr ST Poles and transportation to Divisional Store |
| 107 | Dismantling , Stackingof PCC Poles and transportation to Divisional Store |
| 108 | Dismantling of 0.03/0.05/0.1 ACSR Conductor and transportation to Divisional Store |
| 109 | Supply ,installation, testing and commissioning of 11kV Pilfer resistant metering cubicle for 3phase 4 wire metering system made of MS Sheet steel thickness not less than 2mm duly power coat painted suitable for indoor as well as outdoor as per the site requirement. The cubicle shall be painted through 7-tank process. The External dimensions should be adequate. Panel having two compartments upper Meter compartment and lower CT/PT compartment. Provided with synthetic or semi synthetic gasket firmly glued to the surface, Dust, weather and Vermin proof and shall comply degree of protection IP 65 both the chambers having one sided hinged door arrangements. The metering panel shall be provided with two No MS channels of size 100 x 50 mm on the front and rear sides duly welded and 4 No of lifting hooks. It should be possible to take meter reading manually, through CMRI and computer without opening the LV chamber door. ( for 11 KV trivector meter) |
| 110 | Single Phase, Single core, single ratio, Epoxy resin Cast Current Transformers suitable for 11kV, copper wound primary type with rated burden 5VA and accuracy class 0.5 or better and conforming to IS2705 (part-I & II) ( for 11 KV trivector meter)amended upto date. ISF shall be upto 5The CT ratio shall be as under:75/5 for 1MVA DT50/5 for 630 KVA DT25/5 for 400 KVADT20/5 for 250 KVADT15/5 for 200 KVADT7.5 /5 for 100 kva DT5 /5 for 63 kva DT2.5/5for 25 kva DT |
| 111 | Supply ,installation, testing and commissioning of11kV/ 110 V, Three phase epoxy resin cast PT with rated burden 15VA per phase and accuracy class 0.5 or better and conforming to IS:3156 (part-I&II) amended upto date with proper colour coded identification. PTs shall be of uniform insulating and withstand separate source 23kV of for one minute. ( for 11 KV trivector meter) |
| 112 | Supply ,installation, testing and commissioning of Bus Bar.details:CTs bus bar:- 40x6 mm copper strip or adequate sizePTs bus bar: Copper wire 8 SWG or 30x0.6mm copper flat strip to connect PT terminal or adequate sizeduly insulated by the monopolist tape |
| 113 | PVC Copper wire flexible multi-strand of required size for secondary connections for CT wiring the minimum wire size shall be 4 mm2 (RYB) and for PT wiring minimum wire size shall be 2.5 mm2 (RYB). ( for 11 KV trivector meter) |
| 114 | Supply ,installation, testing and commissioning ofCopper lugs preferably ring type duly crimped for terminationof wiresand tapes ( for 11 KV trivector meter) |
| 115 | Supply ,installation, testing and commissioning ofGrounding bus of minimum 40mm copper, 25cm long fixed to the unit in HV chamber. The CTs, PT meter and 11kV Cable sheath shall be grounded to the bus through grounding wire (green) of min size 10mm2 ( for 11 KV trivector meter) |
| 116 | 3Ph3 Wire HT CT/PT operated Fully static Smart Tri-Vector Energy meters DLMS Compliant Category \"C\" with RS232 port for modem compatibility. 11kV/110V, Ph-Ph (3P,3W) meters for measurement of different electrical parameters including Active Energy (kWh/ MWh), Reactive Energy (kVArh/MVArh), Apparent Energy (kVAh/ MVAh) etc. (make L&T, Secure, ABB) ( for 11 KV trivector meter) |
| 117 | Supply ,installation, testing and commissioning of Independent flexible PVC pipes for CT wiring and PT wiring of appropriate size from HT compartment to meter compartment ( for 11 KV trivector meter) |
| 118 | Supply ,installation, testing and commissioning ofpedestal made out of MS Channel of size 75 x 40 mm or angle iron of size 65 x 65 x 5 mm, duly painted as per site requirement for mounting of metering panel including concrete foundation wherever required including cost of nuts and bolts ( for 11 KV trivector meter) |
| 119 | Supply ,installation, testing and commissioning of 3 Core 11 kV Aluminium cable XLPE armoured 35 mm2 including cost of clamp for its fixing where ever required ( for 11 KV trivector meter) |
| 120 | Supply ,installation, testing and commissioning ofCable termination kits suitable for 3 x 35 mm2 XLPE Cable (indoor/outdoor) ( for 11 KV trivector meter) |
| 121 | Supply ,installation, testing and commissioning of Earthing by way of 40 mm GI Pipe Earthing . Job includes , excavation, enhancement material and Main Hole Chamber (500x450x600) with frame and cover. ( for 11 KV trivector meter) |
| 122 | Dismantling of 0.03/0.05/0.1 ACSR Conductor / Cable / Scrap and transportation to Divisional Store |
| 123 | Providing and fixing of Suspension/Tension Clamp with eye hook |
| 124 | Providing and fixing of Suspension/Tension Clamp with eye bolts |
| 125 | transportation/ carriage of damaged/ Repaired distribution transformerof the capacity 16 KVA/25 KVA/63 KVA/ 100 KVA from varioussite within the jurisdiction of EDIV Khanyar to Divisional Workshop khanyar and backfrom Divisionalworkshop Khanyat to various sites ( To & Fro ) |
| 126 | transportation/ carriage of damaged/ Repaired distribution transformerof the capacity200 KVa/250KVA/300KVA/400 KVA KVA from varioussite within the jurisdiction of EDIV Khanyar to Divisional Workshop khanyar and backfrom Divisionalworkshop Khanyat to various sites ( To & Fro ) |
| 127 | transportation/ carriage of damaged/ Repaired distribution transformerof the capacity 500VA/630KVA/1000 KVA from varioussite within the jurisdiction of EDIV Khanyar to Divisional Workshop khanyar and backfrom Divisionalworkshop Khanyat to various sites ( To & Fro ) |
| 128 | Providing and laying of cement bottoming for 11mtr pole 0.6 cum / pole 1:2:4 ratio as per standard |
| 129 | Providing and laying of cement bottoming for 9 mtr pole 0.5 cum / pole 1:2:4 ratio as per standard |
| 130 | Providing and laying of cement bottoming for 8 mtr pole 0.45 cum / pole 1:2:4 ratio as per standard |
| 131 | Providin of skilled labourer along with all necessary tools/equipment\"s for trimming of branches, cutting of branches , trees in HT/LT corridorsas identified by concerned subdivisions for minimising faults or other works[ Complete adherence to safety protocols, labourers experienced in working in electrical systems and employment completely as per Labour laws of the UT] |
| 132 | Providing of unskilled labourer along with all necessary tools/equipment\"s for helping trimming of branches, cutting of branches , trees in HT/LT corridorsas identified by concerned subdivisions for minimising faults or other works [ Complete adherence to safety protocols, labourers experienced in working in electrical systems and employment completely as per Labour laws of the UT] |
| 133 | Supply, installation ,testing and commissioning of Bi metallic Brass- AluminumLT Bushrod clamps competable for 42 mm LT bush rod suitable for 1300 Amp current , 8 \" long,3\" breadth & 1\" thickness , weighing not less than 1000 Gms. |
| 134 | SSupply, installation ,testing and commissioning ofBi metallic Brass- AluminumLT Bushrod clamps competable for 32 mm/24 mm LT bush rod suitable for 1000 Amp current , 6 \" long,2.5\" breadth & 0.75\" thickness , weighing not less than 600Gms. |
| 135 | Supply, installation ,testing and commissioning of Bi metallicBrass- AluminumLT Bushrod clamps competable for 19 mm /16mm/12mm LT bush rod suitable for 800/400 Amp current , 5 \" long,2\" breadth & 0.5\" thickness , weighing not less tham 500 Gms. |
| 136 | Supply, installation ,testing and commissioning of AluminumLT thimbles s compatable for 630 mm LTCablesuitable for 1000 Amp current |
| 137 | Supply, installation ,testing and commissioning ofAluminumLT thimbles s compatable for 400 mm LTCablesuitable for 800 Amp current |
| 138 | Supply, installation ,testing and commissioning of AluminumLT thimbles s compatable for 300mm LTCablesuitable for 500 Amp current |
| 139 | Supply, installation ,testing and commissioning o fAluminumLT thimbles s compatable for 240mm LTCablesuitable for 500 Amp current |
| 140 | Supply, installation ,testing and commissioning of AluminumLT thimbles s compatable for 185mm LTCablesuitable for 300 Amp current |
| 141 | Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of PCC Poles 8 mt long with pit excavation(Note: The poles shall be provided by KPDCLwhich is to be lifted from upto 2 Km sfrom nearby location of the installation site ). |
| 142 | Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of PCC Poles 9 mt long with pit excavation(Note: The poles shall be provided by KPDCLwhich is to be lifted from upto 2 Km sfrom nearby location of the installation site ). |
| 143 | Supply and Fixing of Cable tie |
| 144 | Supply and Fixing of Cable end Caps |
| 145 | Supply, Laying, Testing and Commissioning of 4 core 35-120 mm2 PVC Cable from AB Cable taping point through Piericing connector to PMDB including P/F of Thimbles/Clamps |
| 146 | Supply and fixingof Piercing Connector forconnections (main line 120-240 Sqm/branch line section 4-25 Sqm) insulated and insulated branching and bare and insulated branching in case of neutral messenger |
| 147 | Supply and fixing of Piercing Connector for DB connection from main ABC to DB (main line 120-240 Sqm/branch line section 35-50 Sqm) insulated and insulated branching and bare and insulated branching in case of neutral messenger |
| 148 | Supplyand Fixing of Piercing connector for ABC to ABC Tee connection (main line 120-240 Sqm/branch line section120-240 Sqm) insulated and insulated branching and bare and insulated branching in case of neutral messenger |
| 149 | Supply installation, testing and commissioning of 3 Phase SMDB (Service Main Distribution Box) IP54 made from20 SWG CRCA MS sheetby Deep drawn method with connection terminals for R,Y, B & N as per specifications. Internal size of the box shall be 225mm x 285mm x 120mm used for connection through ABC line andfor giving connections to the consumers 3phase-1 incoming 4 outgoing I/C- 1, O/G-2-4 (200 A, 0.415 kV) for RYB Phase. The DB should have Bottom entry of Cable with proper Glands/grommets-Safety Screws and Back Clamp suitable for 11/9/8 Mtr ST Pole or 9/8 mtr PCC poles with Nuts/bolts. The job also includes disconnection/reconnection of consumer energy meter and aluminium lugs, if required. |
| 150 | Providing and Fixing of Insulation tape (red / yellow / black) |
AI Tender Summary
Tender Timeline
May 12, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedMay 30, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMay 31, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer