Tender Details

Tender For Construction Of Administrative Building Of Drugs Control Administration, Bhubaneswar.-- 1 Civil Workearthwork In Excavation In All Types Of Soil For Site Leveling, Foundation, Pits, Trenchesand Other Civil Works Upto And Including 1.5Metre Depth And Stacking The Soil Upto A Lead Of 100 Metre And Including Dewatering, Removing Slush, Shoring And Strutting ( As Required ) , Complete As Per Specification And As Directed By The Engineer-In-Charge. 2 Stilt Floor 3 All Kinds Of Soil 4 Disintegrated Rock 5 Road 6 Drain 7 Parking 8 Filling At All Depth With Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 15Cm In Depth:Consolidating Each Deposited Layer By Ramming And Watering Complete ( Lead Upto 100M ) As Directed By The Engineer-In-Charge. 9 Stilt Floor 10 Road 11 Drain 12 Parking 13 Supplying And Filling In Foundation And Plinth With Good Quality River Sand Including Watering, Ramming With Cost, Conveyances, Royalties Of All Materials And Cost Of All Labour With T&P Required For The Work Etc. Complete As Per Specification & Direction Of Engineer-In-Charge 14 Stilt Floor 15 Drain 16 Parking 17 Disposal Of Surplus Excavated Materials By Mechanical Means From The Work Side Etc. Complete. Upto 5Km. Leadincluding Cost Of All Labour T&P Required For The Work Etc. Complete As Directed By Engineer-In-Charge. 18 Stilt Floor 19 Supplying, Diluting & Preparing Chemical Emulsion Like Imidaclosed 30.5% Sc Or Other Chemicals Approved By Central Insecticides Board Or As Directed By Manufacture And Spraying The Mixture Uniformly By Sprayer As Pre-Constructional Anti Termite Treatment Confirming To Is 6313 ( Part-Ii ) And Creating A Chemical Barrier Under And Around The Column Pits, Wall Treanches, Basement Excavation, Top Surface Of Plinth Filling, Junction Of Walls And Floors Along With External Perimeter Of The Building, Expansion Joints, Surrounding Of Pipes And Conduits Etc. At The Rate Of 7.5Liters Per Sqm On Vertical Surface And 5.0Liters Per Sqm On Horizontal Surface, 50% Of The Emulsion To Be Filled In The Holes Made In Treanches At 150Mm Centre To Centre ( Or As Directed Directed By The Manufacture ) Including The Cost Of All Material, Cost Of All Labour, Conveyance, Loading, Unloading, T&P, Etc All Complete As Per The Direction Of Engineer-In-Charge. ( Approved Rate For Mph Building Sl No-1 ) 20 Stilt Floor 21 Cement Concrete Of Proportion ( 1:4:8 ) In Foundation And Floors Using 4Cm Size Clean Hard Black Crusher Broken Granite Stone Metal Of Approved Quality And From Approved Quarry Including Hoisting, Lowering And Laying Concrete In Layers Not Exceeding 15 Cm. ( 6 ) Thick To The Required Level Ramming, Watering, Curing Etc. Complete Including Cost, Conveyance, Royalties Of All Materials With All Labour And T&P Required For The Work Etc. Complete In All Respect And As Per The Direction Of The Engineer-In-Charge. 22 Stilt Floor 23 Drain 24 Providing And Laying Plain Cement Concrete Of Proportion ( 1:3:6 ) In Foundation And Floors Using 4 Cm. Size Black Hard Crusher Broken Granite Stone Metal And Screened And Washed Sharp Sand For Mortar Of Approved Quality And From Approved Quarry Including Hoisting, Lowering, Laying Concrete, Ramming, Watering And Curing Etc. Complete To Required Levels Laid In Layers Not Exceeding 15 Cm. Thick In Each Layer Including Cost, Conveyance, Royalties Of All Materials And Cost Of All Labours, Labour Cess, T&P Etc Complete As Per The Direction Of The Engineer-In-Charge. 25 Stilt Floor 26 Road 27 Plain Cement Concrete ( 1:2:4 ) Using 12Mm Size Black Hard Crusher Broken Granite Chips Of Approved Quality From Approved Quarry Including Hoisting, Lowering And Laying Concrete In Layers, Watering, Curing Etc. Complete Including Cost, Conveyance, Royalties Of All Materials With Labour, Labour Cess And T&P Etc. Required For The Work Complete As Per The Direction Of The Engineer-In-Charge. 28 Stilt Floor 29 Fly Ash Brick Masonry In Cement Mortar ( 1:6 ) In Foundation & Plinth Using Fly Ash Bricks Of 23 X 11 X 8 Cm Size Having A Crushing Strength Of Not Less Than 75 Kg. / Sqcm With Dimensional Tolerance ± 2% Including Splays Cutting Circular Moulding Chamfering And Corbelling And Similar Such Type Of Works With All Necessary Projections Watering And Curing After Immersing The Bricks In Water At Least For Six Hours Before Use Including Cost, Conveyance, Royalties Of All Materials With All Labour, Labour Cess And T & P Required For The Work Complete In All Respect As Per Direction Of Engineer-In-Charge. 30 Stilt Floor 31 Fly Ash Brick Masonry In Cement Mortar ( 1:6 ) In Super Structure Using Fly Ash Bricks Of 23 X 11 X 8 Cm Size Having A Crushing Strength Of Not Less Than 75 Kg. / Sqcm With Dimensional Tolerance ± 2% Including Splays Cutting Circular Moulding Chamfering And Corbelling And Similar Such Type Of Works With All Necessary Projections Watering And Curing After Immersing The Bricks In Water At Least For Six Hours Before Use Including Cost, Conveyance, Royalties Of All Materials With All Labour, Labour Cess And T & P Required For The Work Complete In All Respect As Per Direction Of Engineer-In-Charge. 32 Stilt Floor 33 First Floor 34 Second Floor 35 Third Floor 36 Terrace Floor 37 Fly Ash Brick Masonry In Cement Mortar ( 1:4 ) In Super Structure Using Fly Ash Bricks Of 23 X 11 X 8 Cm Size Having A Crushing Strength Of Not Less Than 75 Kg. / Sqcm With Dimensional Tolerance ± 2% Including Splays Cutting Circular Moulding Chamfering And Corbelling And Similar Such Type Of Works With All Necessary Projections Watering And Curing After Immersing The Bricks In Water At Least For Six Hours Before Use Including Cost, Conveyance, Royalties Of All Materials With All Labour, Labour Cess And T & P Required For The Work Complete In All Respect As Per Direction Of Engineer-In-Charge. 38 Stilt Floor 39 First Floor 40 Second Floor 41 Third Floor 42 Providing, Lifting, Hoisting And Laying Reinforced Cement Concrete Of M-25 Grade As Per Approved Designs And Drawings Having A Minimum Compressive Strength ( In Work Test ) 25 Kg. / Square Cm. In 15 Cm. Cubes At 28 Days After Mixing And Test Conducted In Accordance With I.S. 516 Using 12 Mm. To 20 Mm. Size Black Hard Crushed Broken Granite Stone Chips And Screened And Washed Sharp Sand For Mortar Of Approved Quality From Approved Quarry, Washed Andcleaned ( 20Mm. Size Chips Not To Exceeds 25 % ) To Be Mixed In Concrete Mixture With Portlandslag Cement ( Psc ) Including Hoisting, Lowering, Laying And Compaction Concrete By Using Vibrators, Watering And Curing For 28 Days, Centering And Shuttering Then After Dismantling And Removing Debris From The Work Site And Finishing The Exposed Surface Smooth Providing Grooves Or Beads Wherever Necessary Including Cost, Conveyance, Loading, Unloading, Royalties And Taxes Of All Materials And Cost Of All Labours, Sundries, T & P Required Of The Work Etc. Complete In All Respect As Directed By The Engineer-In-Charge. But Excluding Cost And Conveyance Of M.S. Rods Or Tor Steel And Binding Wires And Labour Charges For Straightening, Cutting, Bending Etc. Of M.S. Rods Or Tor Steel Tying The Grills And Placing In Proper Position. 43 Foundation 44 Stilt Floor 45 Drain 46 Plinth Beam 47 Stilt Floor 48 Column Up To Pl 49 Stilt Floor 50 Column In Superstructure 51 Stilt Floor 52 First Floor 53 Second Floor 54 Third Floor 55 Terrace Floor 56 Drain 57 Lintel 58 Stilt Floor 59 First Floor 60 Second Floor 61 Third Floor 62 Terrace Floor 63 Roof Beam 64 Stilt Floor 65 First Floor 66 Second Floor 67 Third Floor 68 Terrace Floor 69 Roof Slab 70 Stilt Floor 71 First Floor 72 Second Floor 73 Third Floor 74 Terrace Floor 75 Drain 76 Staircase 77 Stilt Floor 78 First Floor 79 Second Floor 80 Third Floor 81 Chajja 82 Stilt Floor 83 First Floor 84 Second Floor 85 Third Floor 86 Terrace Floor 87 R.C.C. Work Of M-20 In Following Works Using 12 Mm. To 20 Mm. ( ½” To ¾” ) Size ( 20 Mm. Not To Exceed 25% ) Hard Black Crusher Broken Granite Stone Chips Of Approved Quality From Approved Quarry Including Hoisting, Lowering, Laying And Compacting Concrete, Watering Curing, Centering, Shuttering And Finishing The Exposed Surfaces Smooth With Cost, Conveyance, Royalties, Taxes Of All Materials With All Labour, Labour Cess And T & P Required For The Work Etc. Complete In All Respect But Excluding The Cost And Conveyance Of M.S. Rods Or Tor Steel And Binding Wire Of 18 To 20 Gauge And Labour Charges For Straightening, Cutting, Bending, Binding And Tying The Grills And Placing In Proper Position And As Per The Direction Of The Engineer-In-Charge. 88 Road 89 Parking 90 Supplying Cutting, Straightening Coiled Or Bent Up M.S. Rod Or Tor Steel Of Primary Steel Producers Such As Sail / Tiscon / Rinl / Jindal Steel / Shyam Steel ( Grade Fe-500D ) Etc. Includingbending, Binding, Welding And Jointing If Necessary And Tying The Grills And Placing In Position As Required For R.C.C. Work And For Providing Fan Hooks As Required, Hoisting, Lowering, Laying Including Cost, Conveyances Of M.S. Rod Or Tor Steel And Binding Wires Of 18 To 20 Gauge And Labour Required For The Work For Bending, Binding And Tying The Grills In All Floors With Labour Cess Etc. ( Payment Will Be Made On Standard Weight Of B.I.S. For M.S. Rods Or Tor Steel Only ) Etc. Complete As Per Specification & Direction Of Engineer-In-Charge. 91 Stilt Floor 92 First Floor 93 Second Floor 94 Third Floor 95 Terrace Floor 96 Road 97 Drain 98 Parking 99 Providing 12 Mm Thick Cement Plaster With Cement Mortar Of Mix ( 1:6 ) With Screened And Washed Sharp Sand For Mortar And Finished Smooth To The Rough Surface Of Walls In All Heights After Racking Out Joints Including Watering And Curing, Rounding Of Corners, Providing Grooves Where Ever Necessary With Cost, Conveyance, Royalties Of All Materials With Cost Of All Labour, Labour Cess, T&P, And Scaffolding Required For The Work Etc. Complete In All Respect As Directed By The Engineer In Charge. 100 Stilt Floor 101 First Floor 102 Second Floor 103 Third Floor 104 Terrace Floor 105 Providing 16 Mm Thick Cement Plaster With Cement Mortar Of Mix ( 1:6 ) With Screened And Washed Sharp Sand For Mortar And Finished Smooth To The Rough Surface Of Walls In All Heights After Racking Out Joints Including Watering And Curing, Rounding Of Corners, Providing Grooves Where Ever Necessary With Cost, Conveyance, Royalties Of All Materials With Cost Of All Labour, Labour Cess, T&P, And Scaffolding Required For The Work Etc. Complete In All Respect As Directed By The Engineer In Charge. 106 Stilt Floor 107 First Floor 108 Second Floor 109 Third Floor 110 Terrace Floor 111 Providing 6 Mm Thick Cement Plaster With Cement Mortar Of Mix ( 1:4 ) With Screened And Washed Sharp Sand For Mortar And Finished Smooth To R.C.C. Work After Closed Deep Chipping & Slurry Treatment Including Watering And Curing, Rounding Of Corners, Providing Grooves Where Ever Necessary With Cost, Conveyance, Royalties Of All Materials With Cost Of All Labour, T&P, And Scaffolding Required For The Work Etc. Complete In All Respect As Directed By The Engineer In Charge. 112 Stilt Floor 113 First Floor 114 Second Floor 115 Third Floor 116 Terrace Floor 117 Supplying, Fitting And Fixing Vetrified Tiles Of Premium Grade Having Thickness 8Mm To 10Mm Confirming To Is 13756 Of Size 600Mm X 600Mm Plain ( Ivory ) Of Approved Make ( Johnson / Somany / Kajaria / Oasis / Rak ) As Directed By Engineer-In-Charge In Floors On 20Mm Thick Bed Of C.M. ( 1:4 ) ( 1Cement:4Course Sand ) And Filling The Joint With White Cement Mixed With Pigment To Match The Shades Of The Tileincluding Cost Of All Materials, Labour, Labour Cess, T&P Etc. Required For The Work Completein All Respect As Directed By The Engineer In Charge. 118 Stilt Floor 119 First Floor 120 Second Floor 121 Third Floor 122 Providing, Fitting, Fixing Vitrified Tiles Of Premium Grade Having Thickness 8Mm To 10Mm Confirming To Is 13756 Of Size 600Mm X 600Mm Plain ( Ivory ) Of Approved Make ( Johnson / Somany / Kajaria / Oasis / Rak ) As Directed By Engineer-In-Charge In Dados Skirting And Risers Of Steps On 12Mm Thick Cement Plaster ( 1:3 ) Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shades Of The Tiles Including Rubbing And Polishing Etc. Complete With Cost, Conveyance, Royalties Of All Materials All Labour, Labour Cess Complete In All Respects As Directed By The Engineer In Charge. 123 Stilt Floor 124 First Floor 125 Second Floor 126 Third Floor 127 Fixing Granite Tiles Of Approved Dimension Area Above 0.4 Sqm ( 20Mm Thick ) In Floor, Treads Of Steps And Landing On 20Mm Thick Bed Of Cement Mortar ( 1:4 ) Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shades Of The Tiles Including Rubbing And Polishing Etc. Complete With Cost, Conveyance, Royalties Of All Materials Complete In All Respects As Per Direction Of Engineer-In-Charge. 128 Stilt Floor 129 First Floor 130 Second Floor 131 Third Floor 132 Fixing Of Kota Stone Tiles Of Minium Thickness 16Mm Thick Of Premium Grade Of Size Above 0.10 Sqm. In Floors Over 20Mm Thick Bed Of Cement Mortar 1:4 ( 1Cement:4Course Sand ) And Filling The Joint With White Cement Mixed With Pigments To Match The Shade Of The Tiles, Including Rubbing & Polishing Etc. Complete Including Cost, Conveyance, Royalties Of All Materials, Labour, Labour Cess With T&P Complete In All Respects As Per Direction Of Engineer-In-Charge. 133 Stilt Floor 134 First Floor 135 Second Floor 136 Third Floor 137 Supplying, Fitting And Fixing Vetrified Industrial Tiles In Floors Of Premium Grade Having Thickness 8Mm To 10Mmof Size 300Mm X 300Mm Confirming To Is 4457 With Colour / Printed Series Of Approved Make ( Johnson / Somany / Kajaria / Oasis / Rak ) As Directed By Engineer-In-Charge On 20Mm Thick Bed Of C.M. ( 1:4 ) Including Cost Of All Materials, Labour, T&P Etc. Required For The Work In All Respect As Directed By The Engineer In Charge. 138 Stilt Floor 139 Wooden Flooring :-Supply &Instaliation Of Badminton World Federation ( Bwf ) Approved Wooden Sports Flooring System Airflex Smash That Should Be Compiiance With The Area Elastic With Total Thickness Of 75 Mm Comprising Of 20Mm Top Solid Wood Followed By 45Mm Solid Wood Runner And 10Mm Power Rubber Pad Product Top Finish To Have Square Edge & Uv Prefinished With Back Side Coating ( Polished Used Of Klumpps Frorn Germany Which Is Sweat And Saliva Resistance According To Din 53160 1 / 2 ) To Have Higher Polish Lite. The Wooden Flooring Should Have Eco-Friendly Manutacturing Process Wih 100% Sustainable And Manageable Plantation Resource With Raw Mateiai The Product Should Have Been Produced Through Kilned And Dried Technology To Maintain Suitable Moisture Content The Top Wood Shouid Necessarily Be Sourced From 100% Sustainable Resource And Should Have With Prefinished Including Sanding & Polishing. Structure Of System Should Be 10Mm Thick Rubber Pad, 45Mm Thick Pine Runner With The Width Of 70Mr, Followed By The 20Mm Top Flooring Top Wood Plank Sizes Should Be 20Rnm Thick, 130Mm Wide And 1830Mm Length. Runners To Be Placed At A Distance Of 305Mm C / C Entire System Should Follow Norms With The En 14904 ( 06 / 2006 ) And Technical Parameters For The Praduct Should Have Friction Of 95 According To En 13036-4, Shock Absorption Of 45% According To En 14808, Vertical Deformation Should Be 1.8Mm According To En 14809 And Vertical Ball Rebound Should Be 99% According To En 12235. ( Approved Rate For Mph Building Sl No-12 ) 140 Third Floor 141 Supplying And Fitting -Fixing Of Un-Plasticised Poly Vinyl Chloride ( Upvc ) ( Fenesta / Ncl Veka Ltd / Prominence / Koemmerling Or Equivalent Make Of Similar Specification ) Threetrack-Three Panel Sliding Window-60-Series Duly Manufactured Using Upvc Reinforced Profiles Of 108Mmx45mmx2.5Mm For Outer Frames & Window Sash Of 39Mmx58mmx2.5Mm Capable Of Mounting Single Glazing System, Structurally Reinforced With Hot Dip Galvanised Up To 50 Microns Of Minimum Thickness Of 1.5 Mm Prefabricated & Welded Through Fusion Welding The Window Frame Shall Be Fitted With 6Mm Thick Clear Tougherned Glass Of Saint-Gobain Make Duly Fixed With Epdm Weathering Seal Resistant And The System Is To Be Installed Using Reinforced Large Coupler At The Site Using Anchor Fasteners, Sliicon Rubber Sealant, Easy Glazing / Deglazing At Site Etc. Including Cost And Conveyance Of All Materials, Accessories, Labour Charges, Materials And Product Conforming To Astm D 638-14, En-477-95 And Other Applicable Codes & Standards. ( Rate Approved From Nirman Soudha Ltr No- 20894, Date-26.05.2022 ) 142 Stilt Floor 143 First Floor 144 Second Floor 145 Third Floor 146 Terrace Floor 147 Providing And Fixing Of 12Mm Thick Clear Toughened Glass Frameless Door With Dorma Premium Fittings Dorma Premium ( 9111198 ) Unilite Package Bts 75, Ul Pt 10 With Cover, Ul Us 10Luck With Cover And Pt 24, Dorma Premium ( 9137121 ) H Type Handle 450Mm, 12Mm Clear Toughened Glass With Cutout And Hole, Including The Cost Of All Materials Hardware Fittings , Cost Of All Labour, Conveyance, L Oading, Unloading, T&P, Etc Complete As Per The Direction Of Engineer-In-Charge. ( Approved Rate For Mph Building Sl No-18 ) 148 Stilt Floor 149 First Floor 150 Second Floor 151 Third Floor 152 Dressed Seasoned Sal Woodworkframed Andfixedinframesofdoors&Windows Including Cost, Conveyanceofall Materials And Cost Of Labour For Fitting, Fixing Etc.Complete As Per The Instruction Of Engineer-In-Charge. 153 Stilt Floor 154 First Floor 155 Second Floor 156 Third Floor 157 Providing And Fixing 30Mm Thick Flush Door Shutters Conforming To Is:2002 ( Part I ) Decorative Type , Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Face Of Shutters Inclusive Of 4 Nos Of Stainless Steel Butt Hinges ( 100 Mm X60 Mm X2.5Mm ) 40Mm Stainless Steel Screws. Cylindrical Lock ( Godrej-9843 ) , Tower Bolt Ss 10 X 300 Mm ( Bathroom ) Godrej 3264, Pvc Door Buffer With Ss Screw , Teak Wood Lipping Around The Edges & Paste With 1.5 Mm Thick Laminate On Both Side Of The Flush Door , Etc. Including The Cost Of All Materials, Hardware Fittings, Cost Of All Labour, Conveyance, Loading, Unloading, T&P, Etc, Complete As Per The Direction Of Engineer-In-Charge. ( Approved Rate For Mph Building Sl No-15 ) 158 Stilt Floor 159 First Floor 160 Second Floor 161 Third Floor 162 Supplying, Fitting & Fixing In All Floors Of M.S. Grills, Grill Gates, M.S. Gates, Garage Door, Collapsible Gates With Top And Bottom Rails, Steel Windows, Critical Frames For Windows, Stair Case And Parapet Railing Made Out Of M.S Square Bar / Flat Including Stair Case Hand Railing With 40Mm. Dia G.I.Pipe Etc. Including Painting Two Coats Over A Coat Of Redoxide Primer As Per Approved Drawing And Designwith Cost Of All Materials & Labour, Labour Cess, T&P, Sundries Etc. Complete In All Respect As Per Specification & Direction Of The Engineer-In-Charge. 163 Stilt Floor 164 First Floor 165 Second Floor 166 Third Floor 167 Terrace Floor 168 Drain 169 Priming One Coat With Wall Cement Primer ( Water Bound ) To Make An Even Finished Surface In All Floors And Heights To Wall Surface Of Approved Make And Shade Including Sand Papering, Applying Putty Wherever Necessary & Cost Of Scaffolding, Staging Charges With Cost, Conveyance, Cost Of All Labour, Labour Cess T&P Etc. Complete As Per The Direction Of The Engineer-In-Charge. ( Make: Asian / Ici / Berger Or Equivalent Make Duly Approved By Engineer-In-Charge ) 170 Stilt Floor 171 First Floor 172 Second Floor 173 Third Floor 174 Terrace Floor 175 Painting Two Coats With Approved Antifungal Weather Seal Paints ( Isi ) Of Approved Colour, Shade On Wall Surface Over A Coat Of Wall Primer ( Isi ) Water Bound Including Sand Papering, Polishing The Surface, Cost, Conveyances, Taxes Of All Materials And Cost Of All Labour, Labour Cess With T&P Etc, Complete As Per Specification & Direction Of Engineer-In-Charge. ( Make: Asian / Ici / Berger Or Equivalent Make Duly Approved By Engineer-In-Charge ) 176 Stilt Floor 177 First Floor 178 Second Floor 179 Third Floor 180 Terrace Floor 181 Finishing Plastered Surfaces Of Walls With Cement Based Wall Putty ( Water Based ) Of Approved Make And Finishing The Surface Smooth And Even By Sand Papering To Receive Painting In Walls, At All Heights With Staging Wherever Necessary With Cost, Conveyance, Cost Of All Labour, Labourcess, All T&P Etc. Required For The Work Complete In All Respect As Per The Direction Of The Engineer-In-Charge. ( Make: Jk White / Birla White Or Equivalent Make Duly Approved By Engineer-In-Charge ) 182 Stilt Floor 183 First Floor 184 Second Floor 185 Third Floor 186 Terrace Floor 187 Painting Two Coats With Plastic Emulsion Paint Over A Coat Of Water Bond Cement Primer To Make An Even Finished Surface In All Floors And Heights To Wall Surface Of Approved Make And Shade Including Sand Papering, Applying Putty Wherever Necessary & Cost Of Scaffolding, Staging Charges With Cost, Conveyance, Cost Of All Labour, Labour Cess, T&P Etc. Complete As Per The Direction Of The Engineer-In-Charge. ( Make: Asian / Ici / Berger Or Equivalent Make Duly Approved By Engineer-In-Charge ) 188 Stilt Floor 189 First Floor 190 Second Floor 191 Third Floor 192 Terrace Floor 193 Painting Two Coat With Approved Synthetic Enamel Paint To New Wood Over A Coat Of Red Oxide Primer Including Cost, Conveyances, Royalties, Taxes Of All Materials And Cost Of All Labour With T&P Required For The Work Etc. Complete As Per Specification & Direction Of Engineer In Charge. ( Make-Asian / Berger / Ici Or Equivalent Make Duly Approved By Engineer-In-Charge ) . 194 Stilt Floor 195 First Floor 196 Second Floor 197 Third Floor 198 Terrace Floor 199 Road 200 Parking 201 Supplying, Fitting And Fixing Of Stainless Steel Of 304 Grade In Hand Railing Using 50Mm Dia Of 2Mm Thick Circular Pipe With Balustrade Of Size 32Mm X 32Mm X 2Mm @ 0.90Mtr. C / C And Stainless Square Pipe Bracing Of Size 32Mm X 32Mm X 2Mm In 3 Rows In Stair Case As Per Approved Design And Specification, Buffing, Polishing Etc With Cost, Conveyance Of All Materials, Cost Of All Labour, Labour Cess, T&P Etc. Required For The Work Complete In All Respect As Per Direction Of The Engineer-In-Charge. 202 Stilt Floor 203 First Floor 204 Second Floor 205 Third Floor 206 Terrace Floor 207 Expansion Joint Treatment Supplying And Fixing Of Elastomeric Membrane Of 200Mm X 2Mm Size For Expansion Joint Sealing From Approved Manufacturer, Fixing With Epoxy Adhesive Of Approved Quality Complete. 208 Stilt Floor 209 Finishing Walls With Textured Exterior Paint Of Required Shade Approved Make And Finishing The Surface To Receive Painting In Walls, At All Heights With Staging Wherever Necessary With Cost, Conveyance, All Materials, Cost Of All Labour, Labourcess, All T&P Etc Required For The Work Complete In All Respect As Per Direction Of The Engineer-In-Charge:New Work ( Two Or More Coats Applied @ 3.28 Ltr / 10 Sqm ) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20Kg / 10 Sqm ( Make: Asian / Berger / Ici Or Equivalent Make Duly Approved By Engineer-In-Charge ) 210 Building Proper 211 Structural Glazing.Providing And Supplying Aluminium Extruded Tubular And Other Aluminium Sections As Per The Architectural Drawings And Approved Shop Drawings, The Aluminium Quality As Per Grade 6063 T5 Or T6 As Per Bs 1474 Including Super Durable Powder Coating Of 60 80 Microns Conforming To Aama 2604 Of Required Colour And Shade As Approved By The Engineer-In-Charge. ( The Item Includes Cost Of Material Such As Cleats, Sleeves, Screws Etc Necessary For Fabrication Of Extruded Aluminium Frame Work. Nothing Extra Shall Be Paid On This Account ) . ( Approved Rate For Mph Building Sl No-30 ) 212 Building Proper 213 Structural Glazing :-Designing, Fabricating, Testing, Protection, Installing And Fixing In Position Semi ( Grid ) Unitized System Of Structural Glazing ( With Open Joints ) For Linear As Well As Curvilinear Portions Of The Building For All Heights And All Levels, Including: ( A ) Structural Analysis & Design And Preparation Of Shop Drawings For The Specified Design Loads Conforming To Is 675 Part N ( The System Must Passed The Proof Test At 1.5 Times Design Wind Pressure Without Any Failure ) , Including Functional Design Of The Aluminum Sections For Fixing Glazing Panels Of Various Thicknesses, Aluminium Cleats, Sleeves And Splice Plates Etc Gaskets, Screws, Toggles, Nuts, Bolts, Clamps Etc, Structural And Weather Silicone Sealants Flashings, Fre Stop ( Bamer ) -Cum-Smoke Seals, Microwave Cured Epdm Gaskets For Water Lightness, Pressure Equalisation & Drainage And Protection Against Fire Hazard Including ( B ) Fabricating And Supplying Serrated M.S. Hot Dip Galvanised Aluminium Alloy Of 6005 T5 Brackets Of Required Sizes, Sections And Profiles Etc. To Accommodate 3 Dimentional Movement For Achieving Perfect Verticality And Fixing Structural Glazing Systern Rigidly To The Rcc / Masonry / Structural Steel Framework Of Building Structure Using Stainless Steel Anchor Fasteners / Bolts, Nylon Seperator To Prevent Bimetallic Contacts With Nuts And Washers Etc. Of Stainless Steel Grade 316, Of The Required Capacity And In Required Numbers ( C ) Providing And Filling, Two Part Pump Filled, Structural Silicone Sealant And One Part Weather Silicone Sealant Compatible With The Structural Silicone Sealant Of Required Bite Size In A Dean And Controlled Factory / Work Shop Environment, Including Double Sided Spacer Tape, Setting Blocks And Backer Rod, All Of Approved Grade, Brand And Manufacture, As Per The Approved Sealant Design, Within And All Around The Perimeter For Noiding Glass ( D ) Providing And Fixing In Position Flashings Of Solid Aluminium Sheet 1 Mm Thick And Of Sizes, Shapes And Profiles, As Required As Per The Site Conditions, To Seal The Gap Between The Building Structure And All Its Interfaces With Curtain Glazing To Make It Watertight. ( Approved Rate For Mph Building Sl No-31 ) 214 Building Proper 215 Providing And Fixing Of Canopy With Wpc ( Wood Plastic Composite ) Wall Cladding Plank With Density 18.84 Kg / M2 As Per Astm D2395.2007A D 792:2000 Water Absorption After 2 Hours 0.33% As Per Astm D1037:2006A Section 23 Method A / D570:1998, Linear Thermal Expansion Coefficient 62.5 Um / M Degree Celcius As Per Astm D696-2008 With All Aluminium Frame Work And Accessories For Fitting The Wpc Sheets Onto The Structural System. The Item Shall Be Inclusive Of The Fittings And Fabrication Costs And The Accessories Required To Do So. It Should Be Resistant To Steam And Crack, With All Necessary Fittings Including Cost Of All Materials, Labour, Conveyance, Loading Unloading, Tools And Plant, Sundries Etc All Complete As Per Techinical Specification And Direction Of Engineer In Charge. ( Approved Rate For Mph Building Sl No-29 ) 216 Building Proper 217 Sun Louvers:-Hi-Steel Aluminum Sun Louvers 84R System Comprises Of 84 Mm Wide And 16 Mm Deep Roll Formed Out Of Aluminum Coils. In Aluminum, Panels Are Made Of 0.5Mm Thick Aluminum Alloy 3105 / 3005 And Carriers Are Made Of 0.9Mm Thick Aluminum Alloy With Cut-Outs To Hold Panels. Aluminum Panel And Carrier Shall Be Polyester Powder Coated With 60-70 Microns. Hi-Steel Sun Louver System Is A Vertical Or Horizontal Wall Sun Shading System. The System Use 84 R Panels That Snap Into Vertically Mounted Frames. The Frames Can Be Mounted On The Exterior Of A Building Over Window Openings, Along Balconies Or Over Open Area On A Building Elevation. The Vertical / Horizontal Frames Are Offered In Two Different Designs That Hold The Panels At Different Angles Of 35 And 45 Degrees. The Ranges Of Angles Provide Air Flow, Sun Shading, Safety From Rainfall And Desired Visibility. 218 Building Proper 219 Gyp Board Ceilling :-Providing And Fixing False Ceiling As Per Anutone / Saint Gobain Or Equivalent Make Duly Approved By Engineer-In-Charge Specifications Made Of Standard G.I. Sections And 12Mm Thick Gyp Board Sheets Inclusive Of All Hangers, Edge Members And Other Clips Complete, With Sheets Fixed With Proper Philip Fastner By Power Drills And Joints Duly Finished Ensuring Level In Line, Complete With Putty, Primer And Painting Of Approved Make And Colour. Cost Includes Cutouts For Electrical Fittings, Materials, Labour, T&P Etc Complete As Per Direction Of The Engineer-In-Charge. ( Basic Rate Of Gypsum Board 12Mm Thk. Rs.303 / Sheet ) . 220 First Floor 221 Second Floor 222 Third Floor 223 Grid Ceiling With Anutonesubtex Nubby Step Edge :-Supply And Installation Of Anutone 15 Mm Glassfiber Steppe Edge Glass Fibre Core Ceiling Tile Of Size 595 X 595 X 15Mm Having All Edges Encapsulated With Chemical Treated Paint & Having Density 100-120 Kgs / M3, Weight 1.5 - 3.0 Kg / M2 Which Is Suspended By Using 0.3Mm Thick And 15 Mm Wide Pre Coated Metal T15 / 24 Grid System. The Technical Parameters Are As Follows :Core - Glassfibre, Fire – Class 1 & P , Acoustics – Nrc 0.95, Climate ( Oc Rh ) – 40, 95, Termite Resistance , Light Reflectance – 85 %, Green ( Rc % ) – 35, Hygiene ( Voc, Clean Room ) – Low, Class 3 Strength, Load Capacity ( Kg ) - Antisag. The T15 / 24Grid System Of 600 X 600 Mm Module Shall Include Wall Angle ( Wa15 ) With Unequal Flanges Of Size 14 X 20 X3000mm Wide, Length 3000Mm, 0.43 Mm Thick Fixed Along The Perimeter Of Wall With The Help Of Nylon Sleeves And Suitable Fasteners At 300Mm Centers. Then Suspend The Main T15 ( Mt15w36 ) Having Flange Width 15Mm / 24 Mm , Height32 / 38 Mm And Length 3600Mm Thickness 0.30 Mm From The Soffit With Help Of Soffit Cleat And Wire At 1200Mm C / C. Cross T15 ( Ct15w12 ) With Flange Width 15 Mm, Height 32 Mm And Length 1200 Mm Is Then Interlocked Into The Pre-Cut Slots In The Main T15 At 600Mm Centers In The Direction Perpendicular To The Main T15. Finally Cross T15 ( Ct15w06 ) Having Flange Width 15 Mm, Height 32Mm And Length 600Mm Are Then Interlocked Into The Pre Cut Slots In The 1200 Mm Cross T15 At 1200Mm Centers Andin Direction Parallel To The Main T15.Anuton Subtex Nubby Steppeedge Of Size 595 X 595 X 15Mm Thick Shall Be Placed Into The Grid Size Of 600 X 600 Mm. Ensure Arrow Marks Behind Subtex Panels Are Orianted In One Direction To Achieve Uniform Shade.Test Certificate Will Be Submmited After Procurement Of Materials. 224 First Floor 225 Second Floor 226 Third Floor 227 Grid Ceiling Magnesium Oxide Vinyl Flim Square Tiles:-Supply And Installation Of 8 Mm Thick Magnesium Oxide Square Edge Magnesia Core Ceiling Tile Of Size 595 X 595 Mm Having Density 1000 Kgs / M3, Weight 8 Kg / M2 Which Is Suspended By Using 0.3 Mm Thick And 24 Mm Wide Precoated Metal T 24 Grid System. The Technical Parameters Are As Follows :Core - Magnesia, Fire – Class 1 & P, Acoustics – Stc 44 - 54 , Climate - 50 , Rh - 95, Termite Resistance , Green ( Rc % ) – 30, Hygiene ( Voc, Clean Room ) – Low, Class 3 , Thermal-0.12 W / Mk. The T 24 Grid System Of 600 X 600 Mm Module Shall Include Wall Angle ( Wa 24 W 30 ) With Unequal Flanges Of Size 14 & 20 Mm Wide, Length 3000 Mm, 0.43 Mm Thick Fixed Along The Perimeter Of Wall With The Help Of Nylon Sleeves And Suitable Fasteners At 300 Mm Centers. Then Suspend The Main T 24 ( Mt 24 W 36 ) Having Flange Width 24 Mm, Height32 Mm And Length 3600 Mm From The Soffit With Help Of Soffit Cleat And Wire Rod Along With Leveling Spring Clip At 1200 Mm C / C. Cross 24 ( Ct 24 W 12 ) With Flange Width 24 Mm, Height 32 Mm And Length 1200 Mm Is Then Interlocked Into The Precut Slots In The Main T 24 At 600 Mm Centers In The Direction Perpendicular To The Main T 24. Finally Cross T 24 ( Ct 24 W 06 ) Having Flange Width 24 Mm, Height 32 Mm And Length 600 Mm Are Then Interlocked Into The Precut Slots In The 1200 Mm Cross T 24 At 1200 Mm Centers Andin Direction Parallel To The Main T 24. Magnesium Oxide Vinyl Square Edge Of Size 595 X 595 X 8 Mm Thick Shall Be Placed Into The Grid Size Of 600 X 600 Mm.Test Certificate Will Be Submitted After Procurement Of Materials. 228 First Floor 229 Second Floor 230 Third Floor 231 Panelling - Wall Paneling With Wooden Salon Salts Surco :- Anutone Or Equivalet.Supply & Installation Ofwall Paneling Of Anutone Slats Surco High Density Fiberboard Made Out Ofpure Pinewood Particles, Fire Resistance- Pink In Colour Core With5 Test Fire Resistance Bs 476 Part 5 , Bs 476 Part 6 , Bs 476 Part 7 Iso 1182 Astm E662 Smoke Density- Melamine Laminated Finish, Perforated Wooden Grooved Hdf Slatsl16-2 ( 2 Mm Grooves @ 8 Mm Centers ) , Tongue-Groove Edge For A Seamless Look Of Lineal Dimension Size 128 Mm X 2440 Mm X 16 Mm Thick Having Density 700 Kg / M3, Weight -9 Kgs / M2 With Back Fleecs From Soundtex Germany Nonwoven Acoustic To Be Pasted On Slats Surco Is To Be Installed By Using Gi Strut System. The Technical Parameters Are As Follows Core Variants - Fiberboard, Climate ( Oc Rh ) – 50, 70 Light Reflectance – 75%, Green ( Rc % ) – 25, Hygiene ( Voc, Clean Room ) – Low, Class 1, Strength, Load Capacity ( Kg ) - Anti Sag, Ball-Impact.The Concealed Wall Paneling System Shall Include Gi Wall Channel ( Wc25 ) Having Thickness 0.45Mm, Length 3600Mm, Unequal Flanges Of 15 & 20Mm And Web Of 25Mm Should Be Fixed Along The Perimeters Of The Wall With Nylon Sleeves And Suitable Fasteners At Every 300Mm Centers. Then Fixed Main Channels ( Mc45 ) Having Thickness 0.9Mm, Length 3600Mm, Equal Flanges Of 15Mm And Web 45Mm From The Side Wall & Fixed At Every 1200Mm Centers With Gi Cross Channel ( Cc25 ) Having Thickness 0.45Mm, Length 3600Mm, Knurled Web 35Mm, Depth Of 25Mm And Equal Flanges 9.5Mm Is Fastened To The Main Channel In The Direction Perpendicular To The Main Channel At Every 600Mm Centers. The Framework Will Maintain 50 / 75 Mm Gap From The Walls. Now Clad The Wooden Slats Surco On The Cc 18 With The Help Of Center & Edge Clips To Get Better Locking Of Slats. The Tongue & Groove Are To Be Properly Aligned To Get Flush Look . Synth Poly Fiber Pf 5 X 50 Wool Of 500 Gsm To Be Filled Between The Horizontal & Vertical Studs As In Filler With The Help Of Wire / Stick 7 Adhesive. Test Certificate Of The Use Products Shall Be Submitted After Procurement Of Materials 232 Third Floor 233 Panelling - Wall Paneling Stretch Fabric Nrc / Hush :- Anutone Or Equivalet.Supply And Installation Of Anutone Stretchable Acoustical Fabric Nrc Fabric System By Using Fr Grade Nrc Fabric Of Size 1700 Mm Width, Shall Be Stretched By Using Wooden Base 10 Mm Thick Rigid Vinyl Stretch Tracks Half Wrap / Full Wrap 15 Mm Fs15 & Mid Seam 15 Mm Fs 15, 15 Mm Pinewood Magnesia Bonded Strand Board, Synthetic Poly Fiber 5X50 Infill With Requisite Accessories & Tools. Pinewood Wood Based Wool Fiber Having 15 Mm Thick Square Edge Is First Installed On The Wall Along The Marking Lines With Metal Fasteners Inserted At 300 Mm Centers Fs 15 Tracks To Be Installed On Wooden Base After Applying Stick S7 Adhesive On Both Surfaces For A True & Continuous Secure Grip, & Heavy - Duty Fasteners At 150 Mm Centers On Both Sides Of Stretch Tracks. Pinewood Wool Panels Having Square Edge Magnesite Bonded Pinewood Fibers Panels Of Size600 X 1200 X15 Mm Having Density 400 Kg / M3 , Weight 4 Kg Which Is Fixed To Gi Channel Cc25 On Walls Placed At 600 Mm Centersvertically / Horizontally With Suitable Fasteners With Mc 45 At 1200 C / C & Wc 25 Is For Supporting The Main Frame.. Synthetic Poly Fiber Anutone Pf 5 X 50 Mm Thick Adhered On Strand Tracks By Following The Fabric Thread Line Or Pattern. The Fabric Nrc Is Stretched & Tucked Into The Stretch Tracks & Secure Into The Locking Jaws So That It Will Be Smooth, Free Of Wrinkles With The Tucking Tools. Note - Minimum 50 Mm Additional Fabric Is Required For Tucking Hence Maximum Module Wall Fabric Width Would Be 1600 Mm The Technical Parameters Of The System Are Core - Pinewood Fibre & Polyfiber Fire - 1 Acoustic - Nrc 0.85 Climate Ocrh - 49, 90 Termite Resistance - Yes , Light Reflectance - Colour Dependant , Green Rc % - 25 , Hygiene ( Voc , Clean Room ) - Low , Class 1. Test Certificate Will Be Submitted After Procurement Of Materials. 234 Third Floor 235 Wooden Panelling With Veener :-Providing, Fitting And Fixing Full Height Wooden Paneling To Walls And Columns Wher Ever Necessary From Floor Lvl To Ceiling Ht Or As Per Drawing / Design Made Out Of 50.8Mmx25.4Mmx1.34Mm Thick Aluminium Rectangular Sections Placed@ 600Mm C / C Both Ways On Grid, On Top Of Grid 12Mm Fire Resistant And Termite Proofply ( Conforming To Is Code :5509 ) To Be Provided With 4Mm Thk Veneer Of Approved Shade And Colour Finished With Melamine Polish As Per Design / Drawing Or As Directed By The Architect / Engineer-In- Charge. The Rate Includes Cost Of Cutouts For Electrical Switches, Light Fixtures, Wall Bracket Fans If Any, All Complete With Materials, Labour, T&P, Taxes Etc. ( Basic Rate Of 12Mm Thk.Sylvan Ply, Marine Ply Rs.968.4 / Sqm & 4 Mm Thk. Veneer Rs.2500 / Sqm ) . 236 Third Floor 237 Providing And Laying Grading Conc. 25 Mm ( Avg. Thickness ) Cement Concrete Of Required Slope Of Mix 1:2:2 ( 1Cement:2Sand:2 Graded Stone Aggregate Of 10 Mm Nominal Size ) Mixed With Approved Water Proof Compound As Per ManufacturerS Specification On Top Of Slab Including Cement Slurry, All Complete, Including The Cost Of Water Proofing Admixture, Which Should Be Approved By The Engineer-In-Charge Prior To Material Procurement By The Contractor. 238 Terrace Floor 239 Waterproofing Treatment :- Terrcae Roof Top Surface :-Providing And Installing Two Component Acrylic Modified Cementitious Waterproofing Coating With Masterseal 551 / Equivalent Over Roof Slab After Carrying Out Pond Test On Roof Slab Filling All Defects, Saturating The Surface Mixing The Products And Then Application In 2 Mm Thickness Myk Power Prufe 800 / Sika / Fosroc Or Equivalent Make Duly Approved By Engineer-In-Charge ( 1.8Kg / Sqm Coverage Rate For 1Mm Thickness ) In Suitable Layers Complete In All Respect, All Materials, Tools, Plant & Labour Complete In All Respect. ( Approved Rate For Mph Building Sl No-05 ) 240 Terrace Floor 241 Dismantling Brick Or Stone Masonry In Lime Or Cement Mortar Above 3M Height Including Stacking The Useful Materials For Re-Use And Removing The Debris With In 50M Lead Including Cost Of All Labour With T&P Etc. Complete As Per The Specification And Direction Of The Engineer-In-Charge. 242 Stilt Floor 243 Dismantling And Removing R.C.C. Columns Beams Slab Staircase Landing Lintels Including Stacking The Useful Materials For Reuse And Removing The Debris Within 50M Lead Including Cost Of All Labour With T&P Etc. Complete As Per The Specification And Direction Of The Engineer-In-Charge. 244 Stilt Floor 245 Construction Of Granular Sub-Base By Providing Close Graded Granular Subbase Grading-Iii Material As Per Table 400-1, Spreading In Uniform Layers With Motor Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Vibratory Roller To Achieve The Desired Density Complete As Per Clause 401 Of Mosrt&H Specifications For Road & Bridge Works ( 4Th Revision ) 246 Road 247 Parking 248 Providing, Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes To Water Bound Macadam ( Wmm ) Specification Including Spreading In Uniform Thickness, Hand Packing, Rolling With 3 Wheeled Steel Roller 8-10 Tonnes In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening / Binding Materials To Fill Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density As Per Clause 404 Of Mosrt&H Specifications For Road & Bridge Works ( 4Th Revision ) 249 Road 250 Parking 251 Treatment Of Expansion Joint On Concrete Road 10Mm ( W ) X 20Mm ( D ) :-At The Time Of Concreting Thermo Cool Of 15Mm Should Be Placed To Bifurcate & Maintained Groove Size Of Minimum 10Mm In Width. After Maturity Of Concrete With Water Curing, Surface Treatment Of Groove Will Be Done Manually To Make It Sure Of Groove Size 10Mm X 20Mm. Air Blower To Be Used To Clean Dust Particle.Providing & Appling 10Mm Backer Rod Must Be Fixed To Fill Up The Bottom Of The Expansion Joint As Per Depth Required. Masking Tape Should Be Fixed Both The Surface Area To Protect The Spillage Of Materials.Providing & Appling Nerolac-Perma Polyseal Pg ( Grey Sealant ) Highly Elastic, Uv Resistance, High Degree Temperature Resistance Upto 100 Degree Centigrade To Be Filled With Caution That No Air Pocket Should Be Form. 252 Road 253 Supplying And Fixing Of 60Mm Thick Cement Concrete Interlocking Paver Block Of M-30 Grade Of Approved Make, Design, Colour And Size Made By Block Making Machine With Proper Compaction Laid In Required Pattern Etc. Complete In All Respect Conforming To Irc Sp-63:2018. 254 Parking 255 E.I. Workinternal Wiring.Recessed Wiring To Light Point / First Light Of Group Control / Call Bell Point / Exhaust Fan Point / Wall Fan Point With 1.5 Sq.Mm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor Of Isi Marked In 20 Mm Dia Non-Metalic Pvcconduit Make-Norpack / Havells Or Equievalant Reputed Make With 6 Amp, 250 V Clip In Type Switch Isi Marked And Ceiling Rose Isi Marked Mounted On G.I Modular Box With Face Plate & Cover Of Suitable Size , With 1.5 Sq.Mm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor As Earth Wire Including All Accesories And Connection As Per Direction Of Engineer In Charge.Make- Finolex / / Havells / Rr Cable / Polycaborequivalent Make Duly Approved By Engineer-In-Charge ) ( Make Of Modular Box, Cover, Switch & Socket-Legrand Myrios / Schneider Opale / Eq ) With 10Years Warenty. 256 Group C 257 Recessed Wiring To Secondary Light Pointlooped From Primary Light Point With 1.5Sqmm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor Of Isi Marked With 20Mm Dia Non-Metallic Pvcconduitmake-Norpack / Havells Or Equievalant Reputed Make With 1.5Sqmm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor For Running Earth Including3 Plate Isi Marked Ceiling Rose With All Accessories & Connection As Per Direction Of Engineer-In-Charge.Make- Finolex / / Havells / Rr Cable / Polycaborequivalent Make Duly Approved By Engineer-In-Charge ) Average Length: 3Mtr. 258 Recessed Wiring To Ceiling Fan Point With 1.5Sqmm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor Of Isi Marked With 20Mm Dia Non-Metallic Pvcconduit Make-Norpack / Havells Or Equievalant Reputed Make With 6 Amp 250V Modular Switch, Stepped Type Moudular Regulator, Base & Cover With 1.5Sqmm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor For Running Earth Including All Accessories & Connection As Per Direction Of Engineer In Charge. Make- Finolex / / Havells / Rr Cable / Polycaborequivalent Make Duly Approved By Engineer-In-Charge ) Group B 259 Recessed Wiring To Twin Control Light Pointwith 1.5 Sq.Mm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor Of Isi Marked In 20 Mm Dia Non-Metalic Pvcconduitmake-Norpack / Havells Or Equievalant Reputed Make With 6Amp, 250 V Clip In Type 2Way Switch Isi Marked And Ceiling Rose Isi Marked Mounted On G.I Modular Box With Face Plate & Cover Of Suitable Size , With 1.5 Sq.Mm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor As Earth Wire Including All Accesories And Connection As Per Direction Of Engineer-In-Charge. ( Make- Finolex / Havells / Rr Cable / Polycaborequivalent Make Duly Approved By Engineer-In-Charge ) Group C 260 Recessed Wiringfor 5 / 6 Amp Socket Outletwith6amp, 250 V Clip In Type Modular Switch Isi Markedmounted On G.I Moular Box With Face Plate & Cover Of Suitable Sizeincluding All Accesories And Connection On Same Switch Board As Per Direction Of Engineer-In-Charge. 261 Recessed Wiringfor 5 / 6 Amp Socket Outlet With 2 X 1.5 Sq.Mm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor Of Isi Marked In 20 Mm Dia Non-Metalic Pvcconduit Make-Norpack / Havells Or Equievalant Reputed Make With 6 Amp, 250 V Clip In Type Switch Isi Markedmounted On G.I Moular Box With Face Plate & Cover Of Suitable Size , With 1.5 Sq.Mm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor As Earth Wire Including All Accesories And Connection On Separate Board As Per Direction Of Engineer-In-Charge.Make- Finolex / Havells / Rr Cable / Polycaborequivalent Make Duly Approved By Engineer-In-Charge ) Group C 262 Recessed Wiringfor2 X 6 Amp Socket Outlet Controlled By 2 Nos6amp, 250 V Clip In Type Switch Isi Markedmounted On Single G.I Moular Box With Face Plate & Cover Of Suitable Sizeincluding All Accesories And Connection On Separate Board As Per Direction Of Engineer-In-Charge. 263 Recessed Wiringfor 6 Pin 16 Amp Socket Outletwith 16Amp, 250 V Clip In Type Switch Isi Markedmounted On G.I Moular Box With Face Plate & Cover Of Suitable Sizeincluding All Accesories And Connection As Per Direction Of Engineer-In-Charge. 25Nos For Stage Light, 3Nos For Aquaguard. 264 Recessed Wiringfor A.C / Power Socket Outletwithindustrial Type Socket Outlet, Plug Top And Metal Chained Cover In Sheet Steel Enclosure, 20A / 32A Sp Mcbincluding All Accesories And Connection As Per Direction Of Engineer-In-Charge. 265 Recessed Wiring To Exhaust Fan / Wall Fan Point With 1.5Sqmm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor Of Isi Marked With 20Mm Dia Non-Metallic Pvcconduit With 6Amp 250V Modular Switch, Base & Cover With 1.5Sqmm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor For Running Earth Including All Accessories & Connection As Per Direction Of Engineer In Charge. ( Make Of Wire Finolex / Polycab / Anchor / Havels / Orient / Eq ) Group B 266 Call Bell Point 267 Recessed Wiringfor3 X 6 Amp Socket Outlet Controlled By 2 Nos6amp, 250 V Clip In Type Switch Isi Markedmounted On Single G.I Moular Box With Face Plate & Cover Of Suitable Sizeincluding All Accesories And Connection On Separate Board As Per Direction Of Engineer-In-Charge. 268 Submain. 269 Recessed Wiring To Submain In 4 X 16 Sq.Mmfrlsh Pvc Insulated Single Core Multistrand Copper Conductor Of Isi Marked Confirming To Is-694 / 1990 In 50 Mm Dia Non-Metalic Heavy Duty Pvc Conduit 1.6 Mm Thick Make-Norpack / Havells Or Equievalant Reputed Make Along With 2 X 10 Sq.Mm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor As Earth Wire As Equired. ( Make- Finolex / Havells / Rr Cable / Polycaborequivalent Make Duly Approved By Engineer-In-Charge ) 270 Recessed Wiring To Submain In 4 X 10 Sq.Mmfrlsh Pvc Insulated Single Core Multistrand Copper Conductor Of Isi Marked Confirming To Is-694 / 1990 In 40 Mm Dia Non-Metalic Heavy Duty Pvc Conduit 1.6 Mm Thick Make-Norpack / Havells Or Equievalant Reputed Make Along With 2 X 6 Sq.Mm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor As Earth Wire As Equired. ( Make- Finolex / Havells / Rr Cable / Polycaborequivalent Make Duly Approved By Engineer-In-Charge ) . 271 Recessed Wiring To Submain In 2 X 6 Sq.Mm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor Of Isi Marked Confirming To Is-694 / 1990 In 25 Mm Dia Non-Metalic Heavy Duty Pvc Conduit 1.6 Mm Thick Make-Norpack / Havells Or Equievalant Reputed Make Along With 1 X 4 Sq.Mm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor As Earth Wire As Equired. ( Make- Finolex / Havells / Rr Cable / Polycaborequivalent Make Duly Approved By Engineer-In-Charge ) 272 Recessed Wiring To Submain In 2 X 4 Sq.Mm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor Of Isi Marked Confirming To Is-694 / 1990 In 20 Mm Dia Non-Metalic Heavy Duty Pvc Conduit 1.6 Mm Thick Make-Norpack / Havells Or Equievalant Reputed Make Along With 1 X 2.5 Sq.Mm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor As Earth Wire As Equired. ( Make- Finolex / Havells / Rr Cable / Polycaborequivalent Make Duly Approved By Engineer-In-Charge ) 273 Recessed Wiring To Submain In 2 X 2.5 Sq.Mm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor Of Isi Marked Confirming To Is-694 / 1990 In 20 Mm Dia Non-Metalic Heavy Duty Pvc Conduit 1.6 Mm Thick Make-Norpack / Havells Or Equievalant Reputed Make Along With 1 X 1.5 Sq.Mm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor As Earth Wire As Equired. ( Make- Finolex / Havells / Rr Cable / Polycaborequivalent Make Duly Approved By Engineer-In-Charge ) 274 Recessed Wiring To Submain In 2 X 1.5 Sq.Mm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor Of Isi Marked Confirming To Is-694 / 1990 In 20 Mm Dia Non-Metalic Heavy Duty Pvc Conduit 1.6 Mm Thick Make-Norpack / Havells Or Equievalant Reputed Make Along With 1 X 1.5 Sq.Mm Frlsh Pvc Insulated Single Core Multistrand Copper Conductor As Earth Wire As Equired. Make- Finolex / Havells / Rr Cable / Polycaborequivalent Make Duly Approved By Engineer-In-Charge ) ( For Switch Board Looping ) 275 Db. Supply And Fixing Of Following Way Three Pole And Neutral, Sheet Steel, Mcb Distribution, 415 V On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate, Interconnections, Phosphatized And Powder Painted Including Earthing Etc. As Required Wih Necessary Mcb , Rccb / Isolators As Required.Note For Mcb- There Should Be Colour Indication For Tripping On , Off & Trip / There Should Be Mid Tripposition For Toggles For Electrical Fault Conditions. ( With 5Years Warenty ) 276 Supply, Fixing, Erecting, Connecting And Commissioning Of Indoor Type Dust And Vermin Proof, Sheet Steel Clad Ready Made, Double Door Horizontal Type Powder Coated Wall Mounted12 Way Spn Distribution Boards For Ldb Suitable For 440 V, Three Phase, 4 Wire 50 Hz Ac Supply Completewith Bottom Detachable Plate For Interconnections Etc As Below.Incommer 1 No-40Adpmcb ( 10Ka ) Outgoings-10A Sp Mcb 10Ka-10Nos. ( Make-L&T / Schneider / Legrand / Eq ) 277 Supply, Fixing, Erecting, Connecting And Commissioning Of Indoor Type Dust And Vermin Proof, Sheet Steel Clad Ready Made, Double Door Horizontal Type Powder Coated Wall Mounted4 Way Tpn Distribution Boards For Pdb Suitable For 440 V, Three Phase, 4 Wire 50 Hz Ac Supply Completewith Bottom Detachable Plate For Interconnections Etc As Below.Incommer 1 No-63Afpmcb ( 10Ka ) Outgoings-10 / 20A Sp Mcb 10Ka-12Nos. ( Make-L&T / Schneider / Legrand / Eq ) 278 Supply, Fixing, Erecting, Connecting And Commissioning Of Indoor Type Dust And Vermin Proof, Sheet Steel Clad Ready Made, Double Door Horizontal Type Powder Coated Wall Mounted4 Way Tpn Distribution Boards For Fldb Suitable For 440 V, Three Phase, 4 Wire 50 Hz Ac Supply Completewith Bottom Detachable Plate For Interconnections Etc As Below.Incommer 1 No-63Afpmcb ( 10Ka ) Outgoings-40A Dp Mcb 10Ka-6Nos. ( Make-L&T / Schneider / Legrand / Eq ) 279 Supply, Fixing, Erecting, Connecting And Commissioning Of Indoor Type Dust And Vermin Proof, Sheet Steel Clad Ready Made, Double Door Horizontal Type Powder Coated Wall Mounted4 Way Vtpn Distribution Boards For Fpdb Suitable For 440 V, Three Phase, 4 Wire 50 Hz Ac Supply Completewith Bottom Detachable Plate For Interconnections Etc As Below.Incommer 1 No-100Afpmccb ( 25Ka ) Outgoings-63A Tp Mcb 10Ka-4Nos. ( Make-L&T / Schneider / Legrand / Eq ) 280 Cable . 281 Supply & Laying Of One Number Of Pvc Insulated And Pvc Seathed / Xlpe Power Cable Of 1.1 Kv Grade Of3.5Core 240 Sq.Mm Direct In Groundincluding Excavation , Sand Cushining Protective Covering And Refilling The Trench Etc. As Required. ( Make-Polycab / Rr Kable / Rhino Cable / Eq ) 282 Supply & Laying Of One Number Of Pvc Insulated And Pvc Seathed / Xlpe Power Cable Of 1.1 Kv Grade Of3.5Core 150 Sq.Mm Direct In Groundincluding Excavation , Sand Cushining Protective Covering And Refilling The Trench Etc. As Required. ( Make-Polycab / Rr Kable / Rhino Cable / Eq ) 283 Laying Of One Number Of Pvc Insulated And Pvc Seathed / Xlpe Power Cable Of 1.1 Kv Grade Of 3.5Core 50 Sq.Mm Direct In Groundincluding Excavation , Sand Cushining Protective Covering And Refilling The Trench Etc. As Required. ( Make-Polycab / Rr Kable / Rhino Cable / Eq ) 284 Laying Of One Number Of Pvc Insulated And Pvc Seathed / Xlpe Power Cable Of 1.1 Kv Grade Of 3.5Core 35 Sq.Mm Direct In Groundincluding Excavation , Sand Cushining Protective Covering And Refilling The Trench Etc. As Required. ( Make-Polycab / Rr Kable / Rhino Cable / Eq ) 285 Laying Of One Number Of Pvc Insulated And Pvc Seathed / Xlpe Power Cable Of 1.1 Kv Grade Of4 Core 16 Sq.Mm Aluminium On Surface As Required. ( Make-Polycab / Rr Kable / Rhino Cable / Eq ) 286 End Termination 287 Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Cable Of 1.1 Kv As Required. 288 3.5C X 240 Sq.Mm 289 3.5C X 150 Sq.Mm 290 3.5C X 50 Sq.Mm 291 3.5C X 35 Sq.Mm 292 4C X 16 Sq.Mm 293 Panel 294 Supply, Installation, Testing & Commissioning Of Floor Mounting Front Operated Front Access Extensible Type Cubicle Panel Totally Enclosed, Dust And Vermin Proof With Ip-42 / 55 Protection With Hinged And Lockabale Doors.Crca Sheets Including Interconnections, Tinned Copper Crimping Lugs, Bonding To Earth And Painting Suitable For Use At 415 V, 3Phase 4 Wire 50 Hz System, And To Withstand A Fault Level Of 35 Ka Symmetrical For 1 Sec At 415 V Complete As Per Specifications, As Required And As Below : All Switchboards Shall Have Provision For Entry Of Cables From The Bottom As Required. All Live Accessible Parts Shall Be Shrouded And All Equipment Shall Be Finger Touch Proof. The Bus Bars Shall Be Insulated With Heat Shrinkable Sleeves.Smc / Dmc Shrouds And Busbar Supports Shall Be Used With Indication Lamp, C.T , Digital Voltmeter, Digital Ammeter And Control Fuse Etc. Complete.Make- Legrand / Schneider / L&T / Siemens / Eq. 295 Mainpanel With 400A 4P Mccb 50Ka -1 No As Incomer, 200A 4P Mccb 36Ka 2 Nos, 100A 4P Mccb 25Ka 6 Nos. 250A 4P Change Over Switch 1Nos, & 63A 4P Mcb 10Ka 10Nos. With E.C Busbars With 4Nos 65Ka Vsd Along With 4Nos 32A Sp Mcb. 296 Ext Light Db With 63A 4P Mcb ( 10Ka ) -1 No As Incomer, 1Nos Timer Switch , 20A Sp Mcb 10Ka-12 Nos, 20A Dp Mcb 10Ka 6Nos. As Outgoing With E.C Busbars . 297 Pump Panel Boardwith 63A 4P Mcb ( 10Ka ) As Incomer , Outgoings-32A 4P Mab 10Ka-2Nos, 20 A Dp Mcb 10Ka-3Nos, Withe.C Busbars. 298 Lift Db With 63A 4P Mcb ( 10Ka ) -1 No As Incomer , 40A 4P Rccb 100Ma -1Nos, 10A Sp Mcb 10Ka-6 Nos As Outgoing With E.C Busbars . 299 Earthing 300 Earthing With Copper Earth Plate 600 Mm X 600Mm X 3.15 Mm Thick Isi Marked Including Accessories And Providing Masonary With Cover Plate Having Loccking Arrangement And Watering Pipe Etc With Charcoal And Salt As Required. 301 Supplying And Laying 25 Mm X 6 Mm Cu Earth Strip Isi Marked At 0.5 Meter Below Ground Level As Strip Earth Electrode Including Soldering Etc. As Required. 302 Supplying And Laying 25 Mm X 6 Mm Cu Earth Strip Isi Marked On Surface Or In Recess For Connection Etc As Required. 303 Providing And Fixing 8 Swg Cu Wire On Surface Or In Recess For Loop Earthing As Required. 304 Fixture 305 Supply, Installation, Testing And Commissioning Of Pre-Wired Fluorescent Fiiting / Compact Fluorescent Fitting / Led Fitting Of All Sizes Complete With All Accessories And Lamp Etc. Directly On Ceiling / Wall Or Recessed In False Ceiling , Including Connection With 1.5 Sq.Mm Fr Pvc Insulated Single Core Multistrand Copper Conductor And Earthing As Required. ( Make: Lighting Technology / Philips / Orient / Jaquar Reputed Make Orequivalent Make Duly Approved By Engineer-In-Charge ) . With 5Years Warenty. 306 Ceiling Mounted Indoortype 24W Batten Typeled Light. 307 Ceiling / Wall Mounted Type 10W Bulk Headluminaire Light 308 Supply, Installation, Testing And Commissioning Of 10W Mirror Light 309 Supply, Installation, Testing And Commissioning Of Ceiling Fan 1200Mm Sweep, Including Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq.Mm Fr Pvc Insulated Single Core Multiatrand Copper Conductor Etc. As Required. 310 Supply, Installation, Testing And Commissioning Of Exhaust Fan Of 300 Mm Sweep 900 Rpm In The Existing Opening, Including Making The Hole To Suit The Size Of The Above Fan, Making Good The Damage Complete, Connection, Etcas Required. 311 Supply &Fixing Of 12W Led Down Light ( S ) . 312 Supply &Fixing Of Led 36W 2X2 Surface Mounted Light. 313 Supply, Installation, Testing And Commissioning Of 6W Ceiling Mounted Indoortyperound Recessedledlight. 314 Supply &Fixing Of 5W Led Wall Decorative Light Accessories. 315 Supply, Installation, Testing And Commissioning Of Wall Fan Of 400 Mm Sweepas Required. 316 Perforated Type Cable Tray 317 Supply And Installation Of Pregalvanised Perforated Type Cable Trays Without Cover. The Rate Shall Include Bends, Tees, All Supporting Brackets, Anchor Fasteners, Screws, Bolts, Nuts Etc., Including Painting Of Cable Trays. Thickness Of Sheet Steel Shall Be 2 Mm. Support Sizes Similar To Ladder Type Trays 318 Size Of Cable Tray :300 Mm X 50 Mm 319 Size Of Cable Tray :150 Mm X 50 Mm 320 Tv / Tel & Data 321 Supplying And Fixing Ofclip In Type Modular Telephone Socket Isi Markedmounted On G.I Modular Box With Face Plate & Cover Of Suitable Size , Including All Accesories And Connection As Per Direction Of Engineer In Charge. 322 Supplying And Fixingof Clip In Type Modular T.V. Antenna Socket Isi Marked Onmounted On G.I Modular Box With Face Plate & Cover Of Suitable Size , Including All Accesories And Connection As Per Direction Of Engineer In Charge. 323 Supplying And Drawing 4 Pair, 0.5 Sq.Mm Fr Pvc Insulated Coper Conductor, Unarmoured Telephone Cable In Existing Surface / Recessedpvc Conduit As Required. 324 Recessed Wiring To Television Point Withcable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated Shielded With Fine Tined Copper Braid And Protected With Fr Pvc Sheath In In Existing Surface / Recessedpvc Conduit As Required As Per Direction Of Engineer In Charge. 325 Supplying And Fixing Of Following Sizes Pvc Conduit Along With Accessories In Recessed Wiring Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 326 20Mm 327 Supplying And Fixing Of 16 / 18 Swg Metal Box Of 200 Mm X 150 Mm X 60 Mm Deepon Surface / Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. ( Tel Junction Box ) 328 Supplying & Commissioning Of Telephone Hand Set. 329 Supplying & Installationof 50 Pair Krone Make Moudles With Locking & Key Arrangements Fabricated With Ms Sheet & Powder Coated To Be Fixed On Concealed Manner Incl. Good The Damages. 330 Supplying & Installationofmatrix Epabx System For 200 Extension Line And 2 Trunk Line As Required. 331 Safety Equipments 332 Supply And Installation Of Rubber Mats 12Mm Thick Of Size 2000Mm X 1000Mm X 12 Mm Thick Electrical Tested With Test Certificate. 333 Supply And Fixing Of Fire Buckets With Angular Fabricated Stand To Fix 4 Buckets In Each Stand For Electrical Fire Protection As Per Standards Of Electrical Inspectorate. 334 Supply And Fixing Of Co2 Fire Extinguisher With Mounting Clamps With Pressure Test Certificate . 335 Supply And Fixing Of Shock Treatement Charts Duly Laminated Along With Separate Colour Single Line Diagram Laminated, To Be Fixed In Electrical Control Panel Room. 336 Supply And Fixing Of First Aid Box With Medicines Complete With Medicine With Three Years Expiry Date To Be Fixed In Electrical Control Panel Room. 337 150-Kva Silent D.G. Set 338 Supply & Delivery Of 150-Kva Silent Dg Sets Along With Engine-Alternator, Control Panel Containing 1 No 200-A, 4P Mccb & Required Protections And Metering Arrangement ( In Tamper Proof Compartment With Locking Arrangement ) With Amf Panel Type With 5-A Digital Kwh Meter & Cts For Dg Set, Etc As Required , Acoustic Enclosure, Diesel Tank, Residential Silencer And Complete As Required As Per The Technical Specification And As Per Direction Of Engineer-In-Charge. 339 Installation, Testing Andcommissioning Of 150-Kva Silent Dg Sets Along With Engine-Alternator, Control Panel Containing 1 No 200-A, 4P Mccb & Required Protections And Metering Arrangement ( In Tamper Proof Compartment With Locking Arrangement ) With 5-A Digital Kwh Meter & Cts For Dg Set, Etc As Required , Acoustic Enclosure, Diesel Tank, Residential Silencer And Complete As Required As Per The Technical Specification And As Per Direction Of Engineer-In-Charge. 340 Dg Set Foundation Including Barbared Wire Fencing / Roof Shade As Required. 341 Tp Meter Box Of150 Kva Dg Set 342 1 No 3 Phase 4 Wire 5Amp Ct Operateddigital Kwh Meter In Tamper Proof Enclosure With Locking And Sealing Arrangement Along With Suitable Bus Bar Arrangement, For Mounting Of C.TS & 200 / 5-A Cts, Cable Termination Arrangement Complete As Required 343 Lightning Arrester. 344 Supply & Fixing Of Lightning Arrester Of Size 2.6 Length Made Of 0.5Diameter Copper Rod, Over Which 5Nos 5 Length Pointed Copper Rods Of 0.3 Diameter With Suitable Size Of Nuts And Bolts. 345 Supplying And Laying 25 Mm X 6 Mm Cu Earth Strip Isi Marked On Surface Or In Recess For Connection Etc As Required. 346 Earthing With Copper Earth Plate 600 Mm X 600Mm X 3.15 Mm Thick Isi Marked Including Accessories And Providing Masonary With Cover Plate Having Loccking Arrangement And Watering Pipe Etc With Charcoal And Salt As Required. 347 Submain. 348 Recessed Wiring To Submain In 2 X 2.5 Sq.Mm Fr Pvc Insulated Single Core Multistrand Copper Conductor Of Isi Marked Confirming To Is-694 / 1990 In 20 Mm Dia Non-Metalic Heavy Duty Pvc Conduit 1.6 Mm Thick Along With 1 X 1.5 Sq.Mm Fr Pvc Insulated Single Core Multistrand Copper Conductor As Earth Wire As Equired. 349 Recessed Wiring To Submain In 2 X 1.5 Sq.Mm Fr Pvc Insulated Single Core Multistrand Copper Conductor Of Isi Marked Confirming To Is-694 / 1990 In 20 Mm Dia Non-Metalic Heavy Duty Pvc Conduit 1.6 Mm Thick Along With 1 X 1.5 Sq.Mm Fr Pvc Insulated Single Core Multistrand Copper Conductor As Earth Wire As Equired. 350 Cable . 351 Laying Of One Number Of Pvc Insulated And Pvc Seathed / Xlpe Power Cable Of 1.1 Kv Grade Of4 Core 16 Sq.Mm Aluminium On Surface As Required. 352 Laying Of One Number Of Pvc Insulated And Pvc Seathed / Xlpe Power Cable Of 1.1 Kv Grade Of 3Core 6 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation , Sand Cushining Protective Covering And Refilling The Trench Etc. As Required. 353 End Termination 354 Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Cable Of 1.1 Kv As Required. 355 4C X 16 Sq.Mm 356 Earthing 357 Earthing With Copper Earth Plate 600 Mm X 600Mm X 3.15 Mm Thick Isi Marked Including Accessories And Providing Masonary With Cover Plate Having Loccking Arrangement And Watering Pipe Etc With Charcoal And Salt As Required. 358 Supplying And Laying 25 Mm X 6 Mm Cu Earth Strip Isi Marked At 0.5 Meter Below Ground Level As Strip Earth Electrode Including Soldering Etc. As Required. 359 Supplying And Laying 25 Mm X 6 Mm Cu Earth Strip Isi Marked On Surface Or In Recess For Connection Etc As Required. 360 Providing And Fixing 8 Swg Cu Wire On Surface Or In Recess For Loop Earthing As Required. 361 External Lighting ( Make-Havels / Phillips / Orient ) 362 Supply &Fixing Of 8W Led Bollards Light. 363 Supply &Fixing Of 12W Led Spike Light. 364 Supply &Fixing Of 6W Led Gate Light. 365 Supply &Fixing Of Decorative Ornamental Led Post Toplight . 366 Supply &Fixing Of 60W Led Streetlight With 6M Gi Pole And All Accessories. 367 Supply &Fixing Of 40W Led Outdoor Type Strip Light 5Mtr Long Roll. 368 Supply &Fixing Of Led Boundery Wall Light. 369 Supplying And Fixing Ofof 50Mm G.I Pipe ( Medium Class ) Along With Accessories Ingroundincluding Cutting & Making Good The Sameas Required. 370 250Kva S / S. 371 11Kv Oh Line & Ss With 250Kva Transformer 372 Supply Of All Materials, Labour And Construction Of 11-Kv Overhead Line From Tapping Point Of Cesu With 10.0 Metre Long200mmx100mm Joist Pole ( 200 Ismb ) , 55-Sqmm Aaac Conductor Complete With Required Insulators, Cross Arms, Stays, Struts, Guarding Complete As Per Site Requirement And Direction Of Engineer-In-Charge. 373 Sub Station Dp With 250Kva Transformer 374 Supply, Installation Testing And Commissioning Of 11 / 0.4Kv Sub Station Dp Structure Made Out Of 10.0 Metre Long Ismb 200 Joist Pole With 400 X 400 X 6Mm Base Plate & One Set Of 11-Kv 400 Amp Horizontal Gang Operated A.B. Switch , 11Kv 400 Amp Horn Gap Fuse , 3Nos. 12Kv Lightning Arrestors Etc Complete With Associated Structural Members Made Out Of Fabricated M.S. Channels, Angles Etc As Per The Approved Drawing Including Cost Of Clamp, Nut Bolts, Painting With 2 Coats Of Red Oxide Primer & 2 Coats Of Aluminium Paint Including Excavation Of Pole Pit In All Kinds Of Soil, Pcc Base Padding, Back Filling Of The Pit With 1:3:6 Pcc, Painting With Two Coats Of Redoxide Primer & Two Coats Of Aluminium Paint, Construction Of Brick Masonary Couping, Fixing Of Danger Board Etc Complete As Required Including Fencing Around The Dp Sructure With M.S Grille 375 Supply, Delivery, Of Energy Efficient Low Loss 250-Kva, 11 / 0.415 Kv Copper Wound Onan Dyn-11 Transformer Complete Including First Filling Of Transformer Oil. 376 Installation, Testing And Commissioning Of Energy Efficient Low Loss 250-Kva, 11 / 0.415 Kv Copper Wound Onan Dyn-11 Transformer Complete Including First Filling Of Transformer Oil. 377 Supply, Laying, Installation, Testing And Commissioning Of 3Core 95Sqmm 11Kv Xlpe ( E ) Cable 378 Supply Of Material , Installation, Testing And Commissioning Of 3Core 95Sqmm 11Kv Xlpeoutdoor Jointing Kit 379 Substation Yard Devlopment Including Barbared Wire Fencing, T / R Plingth , M.S Grille, & Spreading Of Hard Granite Metal, Sand Etc As Required. 380 Panels 381 Supply, Installation And Testing Of L.T. Outdoor / Indoor Floor Mounted Type Distribution Boards Made Out Of 2Mm Thick Cr Sheet Metal Cubicle, Duly Acid Treated For Derusting, Primered And Painted With 2 Coats Of Enamel Paint Of Approved Shade; Dust, Damp & Vermin Proved; Having Hinged Door And Compartmental Arrangementfor Eachequipment& Busbar Chamber Onthe Top Of The Panel Running Horizontally; Having Provision For Cable / Conduit Entry, Earthing Studs As Per Specification Mentioned Below Duly Factory Wired Conforming To The Relevant Issandasperspecial Conditions Of Contract Making Good The Damages Caused Complete As Per The Direction Of Engineer-In-Charge. 382 Outdoor Sub Station Panel 383 Panel Having 420A 3P Mccb ( 50Ka ) -1 No As Incomerwith Suitable Arrangement For Cable Termination Ofcomplete Duly Factory Wired As Per Sld 384 Cables 385 Supply, Laying & Testing Offollowing Sizes Xlpe Insulated, Pvc Sheathed, Strip / Wire Armoured Aluminium Conductor Power Cable Of 1100 Volt Grade Laiddirectly Inground / Onsurface Ofwall / Column / Existing Rcc / Stone Ware / Through G.I. Pipe / Hume Pipe As The Case May Be Including Excavation Of Earth In All Kinds Of Soil & Rock, Sand Cushioning, Protectivecovering, Refillingthetrenchwithsand And Brick Covering But Excluding The Cost Of G. I. Pipe / Hume Pipe And Cable End Terminationcomplete With Making Good The Damages Caused As Required And As Per Direction Of Engineer-In-Charge. 386 Laying Of One Number Of Pvc Insulated And Pvc Seathed / Xlpe Power Cable Of 1.1 Kv Grade Of3.5Core 240 Sq.Mm Direct In Groundincluding Excavation , Sand Cushining Protective Covering And Refilling The Trench Etc. As Required. ( Make-Polycab / Rr Kable / Rhino Cable ) 387 Supply Of Materials And End Termination Of Following Cables Including Supply Of Single Compression Brass Cable Glands, Cable Sockets Etc Complete As Required And As Per Direction Of Engineer-In-Charge. 388 3.5C X 240 Sq.Mm 389 Construction Of Man Hole Chamber For Cable Pulling / Crossing Of Size [ 600Mm ( W ) X 600Mm ( D ) ] Complete Including With Suitable Size Of Hume Pipe, Base Foundation With C.C 1:3:6, 250Mm Brick Walls, Filling The Inside Area With Sand, Removablercc Slab For Chambers With C.C 1:2:4 On The Top, Wall And Top Plastering Etc Complete As Required 390 Providing , Layingand Fixing Ofof 100Mm Diapvc Pipe ( 8Kg / Psi ) Along With G.I / Pvc Accessories Inground For Road Crossing Including Trenching ( 450Mm ) And Refillingas Required. 391 Earthing 392 Earthing With Copper Earth Plate 600 Mm X 600Mm X 3.15 Mm Thick Isi Marked Including Accessories And Providing Masonary With Cover Plate Having Loccking Arrangement And Watering Pipe Etc With Charcoal And Salt As Required. 393 Supplying And Laying 25 Mm X 6 Mm Cu Earth Strip Isi Marked At 0.5 Meter Below Ground Level As Strip Earth Electrode Including Soldering Etc. As Required. 394 Supplying And Laying 25 Mm X 5 Mm Cu Earth Strip Isi Marked On Surface Or In Recess For Connection Etc As Required. 395 Earthing With G.I Earth Pipe 3 Meter Long 40 Mm Dia Isi Marked Including Accessories And Providing Masonary Enclosure With Cover Plate Having Locking Arrangment And Watering Pipe Etc With Charcoal And Salt As Required 396 Supplying And Laying 25 Mm X 6 Mm G.I Earth Strip Isi Marked At 0.5 Meter Below Ground Level As Strip Earth Electrode Including Soldering Etc. As Required. 397 Supplying And Laying 25 Mm X 5 Mm G.I Earth Strip Isi Marked On Surface Or In Recess For Connection Etc As Required. 398 Providing And Fixing 6 Swg G.I. Wire On Surface Or In Recess For Loop Earthing As Required. 399 Supply Of Material & Laying Under Ground / Floor / Wall Including Making End Termination And Testing Of Following Size Of Cu / G.I. Wire For Loop Earthing Of Equipments, Switch Boards & Panels As Required Comlete As Per Direction Of Engineer-In-Charge. 400 8Swg Hdbc Wire On Surface Or In Recess For Loop Earthing As Required. 401 8 Swg G.I Wire On Surface Or In Recess For Loop Earthing As Required. 402 Hvac 403 Supply Of Modular Type Variable Refrigerant Flow / Variable Refrigerant Volume Air Cooled Outdoor Units Suitable For Cooling Only, Having All Hermetically Sealed Inverter Type Scroll Compressor ( S ) , Minimum Two Compressors For Above 14 Hp Modules, Microprocessor Based Controller, Top Discharge Type Condensing Unit ( S ) , With R 410 A Refrigerant, Vibration Isolators, With Suitable Foundation Etc. With Refrigerant-Cooled Pcb For Better Performance Complete As Required. The Unit Shall Deliver The Rated Capacity At Ahri Conditions And Work Even At 49°C Ambient Temperature Without Tripping. The Unit Shall Be Suitable To Work On 380-415 V, 3 Phase, 50Hz Ac Power Supply. The Unit Shall Be Filled With First Charge Of The Refrigerant And Ready For Use As Required. Ms / Gi Powder Coated Stand With Vibration Isolation Pads.The Odu Shall Have Low Noise Condenser Fans With External Static Pressure Of The Outdoor Unit Shall Be More Then 75 Pa To Avoid Hot Air Recirculation, Auto Address Setting, Auto Check Function For Connection Error And Complete With Indoor And Outdoor Units With Individual Controller And With Fittings Etc. The Compressor And Vrv / Vrf Outdoor Make Should Be Same Having Compressor Motor Of 6 Pole. The Unit Shall Also Have Feature To Automatically Modulate The Evaporative Temperature Between 6 Deg C To 11 Deg C With Respect To Load For Better Comfort And Energy Efficiency.The Unit Should Have Free Phase Technology So That Unit Can Work In Case Ofphase Reversal Also Without Tripping Of Units.Make-Lg, Daikin Or Equevalents 404 52 Hp 405 48 Hp 406 60 Hp 407 Supply Of Following Minimu Capacity 4-Way / Round Flow Vrv / Vrf Cassette Type Indoor Ceiling Mounted Unit Equipped With Cordless Remote , Synthetic Washable Media Pre-Filter, Fan Section With Low Noise Fan / Dynamically Balanced Blower, Multispeed Motor, Coil Section With Dx Copper Coil, Electronic Expansion Valve, Outer Cabinet, Drain Pan, Drain Pump, Cassette Grill, Insulation, Necessary Supports, Vibration Isolation Etc, Suitable For Operation On 230 V ± 10%, 50 Hz Single Phase Ac Supply, Complete As Required. The Unit Shall Have Automatic Force Shut Down Provision In Case Of Fire. All Indoor Units Should Have Force Shut Option To Connect With Fire Alarm Adaptor, So That The Unit Automatically Stops In Case Or Fire. The Coolingcapacity Of Indoor Unit Will Be At Air Inlet Conditions Of 27 Degree C Dbt And 19 Degree C Wbt. All 4 Louvers Of The Unit Shall Be Independently Adjustable For Positiion As Per User Preference.Make-Lg, Daikin Or Hitachi. 408 Nominal Capacity 1.05 Tr 409 Nominal Capacity 1.3 Tr 410 Nominal Capacity 1.6 Tr 411 Nominal Capacity 2.07Tr 412 Nominal Capacity 2.6Tr 413 Nominal Capacity 3.3Tr 414 Nominal Capacity 4.1Tr 415 Nominal Capacity 4.6Tr 416 Wall Mounted Type Series 417 Nominal Capacity 1.6Tr 418 Lifting, Shifting, Installation, Testing & Commissioning Of Vrv Out Door Units.Make-Lg, Daikin Or Hitachi 419 162 Hp.Make-Lg, Daikin Or Hitachi 420 Lifting, Shifting, Installation, Testing & Commissioning Of Of The Indoor Units.Make-Lg, Daikin Or Hitachi 421 4 Way / Round Flow Cassette 422 Hiwall Units 423 Supplay, Installation, Testing& Commissioning Of The Copper Refrigerant Pipes With 19Mm / 13Mm With Nitrile Rubber Tube Insulation Of Following Sizes.Make-Lg, Daikin Or Hitachi 424 Gas Line With 19Mm Thick Insulation And Liquid With 13Mm Thick Insulation 425 41.3Mm 426 34.9Mm 427 28.58Mm 428 22.2Mm 429 19.05Mm 430 15.9Mm 431 12.7Mm 432 9.52Mm 433 6.4Mm 434 Supply & Installation Testing And Commission Of Control Wiring Of 2 Core X 1.0 Sqmm Copper Cable Through Suitable Conduits In Between Indoor And Outdoor Units.Make-Lg, Daikin Or Hitachi 435 Supply, Installation, Testing And Commissioningof Hard Pvc Drain Pipe With 9Mm Thick Nytrile Tube Insulation. ( With Necessary Lbow, Sockets & Reducers. ) Make-Lg, Daikin Or Hitachi 436 25Mm Inner Dia 437 32Mm Inner Dia 438 40Mm Inner Dia 439 Supply And Commissioning Of Vrf Systems Including Additional Referigernt R410ain All Respect To Complete The Systemas Per Site Requirements. Make-Lg, Daikin Or Hitachi 440 Lift 441 Providing & Fixing Of 1No. 544 Kgs ( 8 Person ) Gearless Elevator Having Automatic Rescue Operation With 4 Stop, Full Collective Operation With / Without Attendant, Made Of Stainless Steel Car Panel With Rear Side Of The Lift Having Glass Panel With Ss Handrails And 1000Mm Width Stainless Steel Door ( Opening On One Side In All Stop ) Complete In All Respect As Directed By Architect / Engineer-In-Charge. The Rate Includes All Complete With Materials, Labour, T&P, Taxes Etc. Make Mitshubishi, Otis, Johnson Or Thysenkrop Or Equevalents Approved As Per Technical & ManufactureS Specification. 442 Fire Fighting Works 443 A.Fire Protection Work ( A-1 ) Fire Extinguishersproviding & Fixing Of Fire Extinguishers With Necessary Accessories, Stand, Trolley, Etc.6 Kg Abc ( Powder Type ) Fire Extinguisher. In Hp Mild Steel Cylinders Isi Markedfitted With Pressure Indicating Gauge, Internal Tube, Squeeze Lever Type Valve Fully Charged With Abc Powder ( Mono Ammonium Phosphate ) Pressured By Nitrogen Complete In All Respects Including Wall Suspension Bracket And Conforming To Is:15683Safex / Minimax / Safeguard / Fire Tipseqv 444 Isi Marked ( Is:15683 ) Portableafff Mechanical Foamfire Extinguisher, Foam Type Capacity 9 Liters With Gun Metal Cap And Nozzle And Complete In Allrespectsincluding Initial Fill And Wall Suspension Bracketssafex / Minimax / Safeguard / Fire Tipseqv 445 Isi Marked Portable Fire Extinguisher, 4.5 Kg Co2 Type Fire Extinguishers Complete In All Respect Including Initial Fill And Wall Suspension Brackets & Shall Conform Tolatestis 15683Safex / Minimax / Safeguard / Fire Tips 446 Supplying And Installing At Approved Location Approved Make Fire Buckets ( 3 Nos. / Set ) Of 24 Gauge Galvanized Steel Sheet, Standard 9 Litre Capacity And Of Round Bottom Shape, Painted White Inside And Black On The Bottom, Inscribed With Letters Fire In Black And Gold With Dry Clean Fire Sand. The Scope Shall Also Include The Stand For Mounting The Sand Bucket. 447 ( Intaranal Hydrant System ) Fire Riser: Supplying, Installation Testing And Commissioning Of The Following. ‘C Class Ms Pipe As Per Is1239 With Welded / Flanged / Screwed Joints And With Heavy Clamps, Hangers, Brackets Or Pipe Supports ( All With Screwed / Welded Joints ) As Required Including Ms Pipe Of Shorter Lengths, Tapering Connecting Pieces, Short Or Long Bends, Forged Specials Like Sockets, Union Nuts, Elbows, Reducers, Plugs, Tees Etc. Complete To Make The System Operative As Required By Lfa / Tac Authorities.The Pipes Will Have To Be Laid And Fixed On Walls, Ceilings, Into Brick Walls Or Rcc With Lead Anchor Fasteners. The Work Includesmaking Holes In Brick Or Rcc Walls, Slabs / Roofs And Making Good The Damages By Bringing To The Original Condition To The Satisfaction Of The Consultant / Client And Painting Two Coats Of Approved Shade ( Post Office Red ) Of Enamel Paint Over A Coat Of Approved Primer For Over Ground / Overheads Pipes. 448 150Mm.Jindal / Tata 449 100 Mm Jindal / Tata 450 80 Mm Jindal / Tata 451 Supply, Installation, Testing And Commissioning Of Ci Butterfly Valve Of Pn 1.6 Rating With Metal Seat Duly Isi Marked Complete With Nuts, Bolts, Washers, Gaskets Conforming To Is 13095 Of Following Sizes As Required: 150 Mm.Kartar / H-Sarker / Zoloto 452 Size 100 Mm Dia 453 Providing And Fixing Single Headed Hydranthaving Outlet Of 63 Mm Dia ( 2.1 / 2” ) N.B. Hydrant ( Is:5290 ) Landing Valve In Stainless Steel Morris Pattern Instanteous Coupling Type Tac / Lfa Approved & Isi Certified Heavy Type Hydraulically Tested To 1.5 Times Working Pressure With Necessary Nuts, Bolts Etc. Kartar / Newage / Isi Mark 454 Providing & Fixing 63Mm Diarrl Hose Pipe As Peris 636 Type A Tac / Lfaapproved Of 15 Mtr Lengthof Approved Pattern And Size Including Ss Male And Female Coupling Duly Bound Withcopper Wireetc. Complete. Crc / Newage 455 Providing And Fixing Fire Hose Cabinet To House Fire Hydrant & Hose, Including All Other Related Accerrories Fabricated From M.S. Sheet ( 2Mm Thick ) Of Fully Welded Construction Having Front Door With Locking Arrangement, Partially Glazed With 4 Mm Thick Glass. Cabinet Shall Be Powder Coated & Painted With Post Office Red Colour Of Size As Approved By The Engineer-In-Charge To House 15 Mtr.X2 Nos. Hoses. The Hose Box Size Is 750 Mm X 600 Mm X 300 Mm. 456 Supplying & Fixing First Aid Fire Hose Reel Of Thermoplast Braided Suitably Reinforced 20 Mm Size & 30 M Standard Length With 5 Mm Tapering Branch Nozzle, 25Mm Dia. Pipe To Connect To Riser.Hose To Be Swinging Type Wall Mounted Drum & Recessing Into Hose Cabinet To Suit Location Including Fixing With Lead Anchor Fasteners & Bolts ( Including Drum And Swivel Arrangement ) Etc Complete. ( Is 884 ) .Mitras / Newage / Gilpro / Isi Mark 457 Supplying And Fixing Specially Designed Orifice Plates ( Minimum 6 Mm Plate Thickness ) On Hydrant Outlets Of Landing Valves Including Distant Pieces Of Suitable Size For Reducing Delivery Pressure To 3.5 Kg / Sq.Cm At Hydrant Valve , As Required By Lfa Complete With Necessary Accessories, Etc. Complete. 458 Providing And Fixing Stainless Steel Standard Branch Pipe Dia 63 Mm Inlet With Nozzle 20 Mm Dia Outletconforming To Is : 903, Suitable For Instantaneous Connections To Hose Coupling Etc. As Required: Kartar / Isi Mark 459 Providing, Fixing And Testing Forged Brass 25 Mm Dia Screwed Inlet Single Acting Air Release Valve With Asll Accessories. Kartar / Newage / Equivalent 460 Providing, Fixing And Testing Forged25 Mm Dia Screwedball Valve With Accessories.Kartar / Zoloto / H Sarker 461 ( A-3 ) External Hydrant System Supplying, Installation Testing And Commissioning Of The Following ‘C’ Class Mspipe Is 1239 Above 150 Nb Is 3589 Over Ground Pipes And Road Crossing Under Ground With Welded / Flanged Connection With Saddles, Supports ( All With Screwed / Welded Joints ) As Required Including Pipe Of Shorter Lengths, Tapering Connecting Pieces, Short Or Long Bends, Elbows, Reducers Etc. Complete To Make The System Operative As Required By Lfa / Tac Authorities.The Above Groundpipes Willlaid On Concrete Pedestal With Structural Steel Or Steel Bracket& Painting Two Coats Of Approved Shade ( Post Office Red ) Of Enamel Paint Over A Coat Of Approved Primer For Overheads Pipes And Road Crossing Pipeswill Laid Through Humepipe With Wrapping Coating. 462 150 Mmjindal / Tata 463 80 Mm Dia. Jindal / Tata 464 Providing And Fixing Hydrant Valve. With Flanges And Accessories And Supply, Fixing63 Mm Diasssingle Headed Hydrantvalve In The Courtyard Is:5290Including 2 Coats Of Approved Enamel Paint ( Red ) Over A Coatof Primer, Complete With 2.1 / 2” ‘Morris’ Pattern Instaneous Couplings, Etc. Complete. Kartar / Newage / Isi Mark 465 Providing & Fixingapproved63mm Diarrl Hose Pipe As Peris 636 Type A Tac / Lfa Of 15 Mtr. Standard Lengthof Approved Pattern And Size Including Ss Male And Female Coupling Duly Bound Withcopper Wireetc. Complete. Crc / Newage / Isi Mark 466 Providing And Fixing Stainless Steel Standard Branch Pipe Dia 63 Mm Inlet With Nozzle 20 Mm Dia Outletconforming To Is : 903, Suitable For Instantaneous Connections To Hose Coupling Etc. As Required: Kartar / Winco / H Sarker / Isi Mark / Eqv 467 Providing And Fixing Tac Approved Fire Hose Cabinet To House Fire Hydrant & Hose, Including All Other Related Accerrories Fabricated From M.S. Sheet ( 2Mm Thick ) Of Fully Welded Construction Having Front Door With Locking Arrangement, Partially Glazed With 4 Mm Thick Glass. Cabinet Shall Be Powder Coated & Painted With Post Office Red Colour Of Sizeas Approved By The Engineer-In-Charge To House 15 Mtr.X2 Nos. Hoses. The Hose Box Size Is 750 Mm X 600 Mm X 300 Mm . Newage / Winco / Equivalent 468 Supplying And Fixing 4 Way Fire Brigade Service Inlet Of Size 150 Mm Dia.With 4 No. 63Mm ( 2.1 / 2 ) Size Stainless Steelmale Outlets ( Stainless Steel Male Coupling ) Including Metallic Cover Of Mild Steel And Glass Front, Indicator Plates Complete. As Required By Lfa / Tac / Engineer In Charge Kartar / Fire Tips / New Age / Eqv 469 Supplying And Fixing Fire Brigade Draw Out Connection Of Size 100 Mm Dia. Ssmale Outlets ( Stainless Steel Male Coupling ) Including 100 Mm Dia Foot Valveetc. Complete To Be Connected With Fire Water Tank.As Required By Lfa / Tac / Engineer In Charge 470 Supply And Installation, Testing And Commissioningof Isolation Sluice Valves Tested To Isi Marked , Pn 1.6 With Ci Body, Bonnet & Brass Trim Parts, & Having Necessary Companion Flanges, Bolts, Nuts, Gasket Packing And Any Other Spares, Includingindicator For Open And Shut Position To Be Installedas Per Fire Practice Etc Complete. 150 Mm Dia.Kartar / Kalpan / Eqv 471 Supply, Installation, Testing And Commissioning Of 0.05 Cum Air Vessel25 Nb Air Release Valve, Ball Valveandv Pressure Gauge With Matching Socked As Per Direction Of Engineer-In-Charge 472 ( A-4 ) Fire Pumps & Related Accessories Supplying & Installing Completely Testing & Commissioning Of End Suction Back Pull Out Pump Set Having Pump Speed Of 2900 Rpm, Pump Efficiency Not Less Than 65%, With Ci Casing, Bronze Impeller, Ss 410 Shaft & Shaft Sleeve Connected Through Flexible Coupling With A Tefc Sq. Cage Induction Motormounted On A Common Base Frame Fabricated In Ms Channel. Packing Has To Be Of Mechanical Seal. It Has To Be Inclussive Of All The Pump Accessories.The Pump Shall Be Capable Of Giving Not Less Than 150% Discharge At A Head Not Less Than 65% Of The Rated Head. Motor To Be Of Continuous Rating Motor To Be Suitable For 415V, 50Hz, Ac Supply Of 35 Kwratingfor The Above Pumps. Motor Shall Accept + / -10% Variation In Voltage And + / - 3% Variation In Frequency. It Has To Be Of Ie2 Efficiency Class.Etc. Complete.Pump - Motor : Discharge : 2280 Lpm, Head-70 Mtr.Kirloskar / Wilo / Eqv 473 Supplying, Installing, Testing And Commissioning Of End Suction Back Pull Out Pump Set Having Pump Speed Of 2900 Rpm, Pump Efficiency Not Less Than 25%, With Ci Casing, Bronze Impeller, Ss 410 Shaft & Shaft Sleeve Connected Through Flexible Coupling With A Tefc Sq. Cage Induction Motor Mounted On A Common Base Frame Fabricated In Ms Channel.Motor To Be Suitable For 415V, 50Hz, Ac Supply Of 5 To 11 Kwratingfor The Above Pumps. Motor Shall Accept + / -10% Variation In Voltage And + / - 3% Variation In Frequency. It Has To Be Of Ie2 Efficiency Class.Packing Has To Be Of Mechanical Seal. It Has Tio Be Inclusive Of All The Pump Accessories Complete . The Scope Shall Also Include Necessary Coupling, Coupling Guard, Base Frame, Foundation Bolts Etc. Completepump - Motor: Discharge: 180 Lpm, Head: 70 Mtr. Kirloskar / Wilo 474 Supply, Installation, Testing & Commissioning Of Diesel Engine Driven Common Stand By Pump, Horizontal Centrifugal End Suction Typewith Mechanical Seal And Capable To Deliver 2280 Lpm , To Ensure A Minimum Pressure Of 3.5 Kg / Sqcmat Thefarthest Or Topmost Hydrant / Sprinkler. Firepumpshall Have C.I. Casing, Cs Diffusers, Bronze Impeller ( Hard Finished And Dynamically Balanced ) Ands.S. ( 304 ) Shaftwithmechanical Seal. The Installation Shall Be Complete With Necessary Pressure Gauge With Gun Metal Shut Off Cock On Suction & Delivery Side. The Pump Shall Coupled To Not Less Than35 Kw Of Diesel Engine Radiator Water Cooled Type With Speed Not More Than 1800 Rpm And Complete Set Shall Be Mounted On Common Base Frame. Batteries & Battery Leads With Stand, Fuel Tank ( For 6 Hrs. Operation ) With Stand & Gauge Glass, Fuel Piping With Valves. The Quoted Rate Shall Includes Radiator Water Cooling Piping ( If Required ) Coupling Guard And Other Standard Accessories ( As Recommended By Manufacturer ) And Foundation Bolts, Etc. Complete. Pump Shall Be Capable Of Furnishing Not Less Than 150% Of Rated Capacity At A Head Of Not Less Than 65% Of The Rated Head.The Shut Off Head Shall Not Exceed 120% Of Rated Head. Flexible Coupling, Coupling Guard, Anti Vibration Pad& Exhaust Pipe Connection Complete As Required. Pump - Diesel Engine: Discharge:2280 Lpm, Head: 70 Mtr. Kirloskar / Wilo / Eqv 475 Mcc For Fire Pumps :Design, Manufacture, Supply , Installation, Testing And Commissioning Of Following Automated Fire Panel Suitable For 415V, 3 Phase, 4 Wire, 50 Hz Power Distribution System. The Panel Should Be Indoor, Free Standing, Floor Mounting, Sheet Metal Clad, Cubicle, Dead Front, Dust And Vermin Proof, Compartmentalized Design Fabricated Out Of 2Mm Crca Sheet Complete With Cu Busbars, A Separate Earth Bus Bar To Be Provided Through Out The Length Of The Panel. The Incoming And Outgoing Feeders Shall Be Accommodated In A Modular Multitier Arrangement, Adequate Size Cable Alley, Painting, Earthing Numbering, Damper Plate Etc. As Required As Per Direction Of Engineer-In-Charge And As Per Local Fire Authority Requirement.The Panel Shall Be Fabricated By Only Cpri Approved Manufacturer As Per The Details Below Incoming 1 No 200A Fpmccb ( 50 Ka ) , 1 Set Of 400 Amps. Tpncu. Bus Bars With Color Coded Heat Shrinkable Pvc Sleeves. Indicator R, Y, B, On, Off, Trip. Ammeter Lcd Type Display+3 Cts, Voltmeter Lcd Type Displayoutgoingfeeder For Electripumps - 01 No :01 No160 A Tp Mccb, Withstar Delta Starter Contactor And Olr Ratings As Per Type 2 Co-Ordination, With Digital Ammeter, Voltmeter, On, Off Push Button, Local Remote Switch, Auto Manual Seclector Switch Etc. Feeder For Jockey Pump - 01 No:01 No32 A Tp Mccb, Withstar Delta Starter Contactor And Olr Ratings As Per Type 2 Co-Ordination, Withdigital Ammeter, Voltmeter, On, Off Push Button, Local Remote Switch, Auto Manual Selector Switch Etc. Diesel Enginepump - 01 No A ) 25Amps Dpmcb - 01 No ( B ) Battery Charger With Transformer With Rectifier Resistance Dc Ammeter, Dc Voltmeter, Trickle / Booster / Off Selector Switch - 1 No ( C ) 1 Set Of Indicating Lamps For The Following : 1. Phase Indication 2.Battery Charger On 3.Over Load Relay 4. Dc Supply On 5.Control Switch On 6. Engine Fails To Start7. Pump On8. Low Oil Pressure 9. High Water Temperature10. Auto Manual Selector Switch ( D ) 1 Sets Of Push Button Stations For The Following : 1. Engine Start 2. Engine Stop 3. Engine - Hooter Ack 4. Engine - Fault Reset ( E ) Selector Switches ( Engine Control, Mode Selector ) -1 No ( F ) Auxiliary Relays / Contactors / Timer For Sequence Operating For Starting And Stopping Of The Engine - 1 Set ( G ) Hooter For Audio Alarm ( Industrial Type ) - 1 No. ( H ) Automatic Source Transfer Relay With 3 Attempt Starting, High Low Lube Pressure, Timers And Relays As Required And Suitable Contactor.All The Components Shall Be Housed In A Common Cubical Made Of 2Mm Crca Sheet With Required Stiffeners ( If Required ) . The Panel Shall Be Powder Coated Of Approved Color Both Inside & Out Side. The Panel Shall Have Both Bottom & Top Cable Entry Provisions And Panel Shall Be Mounted On Pedestal Of 300 Mm Height. Also Panel Shall Have Sufficient ( Min. 10 Nos ) No / Nc Contacts For Extending The Status ( Annunciation ) Of Fire Pumps To The Fire Alarm Panel.Cpri Approved 476 Earthing With G.L. Earth Plate 300 Mm X 300 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 1.5 Meter Long Etc. With Charcoal / Coke And Salt As Required. 477 Supplying And Laying 25 Mm X 5 Mm G.L Strip At Ground As Strip Earth Electrode, Including Connection / Terminating With G.L. Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of G.L. Nut Bolt & Spring Washer Spaced At 50Mm ) . 478 Cablesupply, Laying Testing And Commissioning Of L.T. Al. Xlpe Armoured / Unarmoured Cable Confirming To Is : 7098 Part - Ii As Per Direction Of Engineer-In-Charge As Per The Description Given Below: 479 3.5 C X 95 Sq.Mmpolycab / Kei / Finolex / Havells 480 4 C X 50 Sqmm.Polycab / Kei / Finolex / Havells 481 12 C X 2.5 Sqmm. ( Cu ) Polycab / Kei / Finolex / Havells 482 4 C X 16 Sqmm.Polycab / Kei / Finolex / Havells 483 Cable End Termination Supply, Fixing, Connection, Testing And Commissioning Of Double Compression Brass Cable Glands And Crimping Type Lugs / Sockets With Necessary Tools And Equipments As Specified In Specifications And Is. The Glands And Lugs / Sockets Shall Be Suitable For Cable Size And Type Mentioned Above. The Job Also Includes, If Necessary, Supply And Fixing Of Extension Busbar Of Same Material On Circuit Breaker / Fsu Or Panel Board Terminal / Connector To Connect Morethan Oneno. Of Parallel Cables Or To Connect Higher Sizecable To Lower Size Unit. The Job Also Includes Earthing The Glands And Armour Of The Cable With Common Earth Bar Or Flexible Copper Mesh. 484 4C X 95 Sq.Mm 485 4 C X 50 Sqmm. Polycab / Finolex / Havells 486 12 C X 2.5 Sqmm. 487 4 C X 16 Sqmm. 488 Cable Tray Supplying And Installingof Perforated G.I.Sheet Cable Tray With Necessaryiron Suspension Supports, Anchor Fasteners Etc. Complete. Maximum Height Of Suspension Shall Not Exceed 500 Mm.Size Of The Tray Is 40Mm X 200Mm X 40Mm And 2Mm Thick. 489 Providing And Fixing Power Wiring With 2 Core X 1.5 Sq.Mm. Pvc Armoured Copper Cable For Wiring Pressure Switches, Etc. Including All Required Material And Labour, Terminations, Etc. Complete.Polycab / Rr Cable 490 Supplying, Installation Testing And Commissioning Of The Following .‘C’ Class Ms Pipe As Peris:1239 Above 150 Nb Is 3589 For Over Ground Pipes With Flanged / Welded And With Heavy Clamps, Hangers, Brackets Or Pipe Supports ( All With Flanged / Welded Joints ) As Required Including Pipe Of Shorter Lengths, Tapering Connecting Pieces, Short Or Long Bends, Ms Specials Like Sockets, Union Nuts, Elbows, Reducers, Plugs, Tees, Bends, Etc. Complete To Make The System Operative As Required By Lfa / Tac Authorities The Pipes Will Have To Be Laid And Fixed In Trenches On Walls, Ceilings, Into Brick Walls Or Rcc With Lead Anchor Fastners. The Work Includes Excavation In All Types Of Soils And Back Filling And Making Holes In Brick Or Rcc Walls, Slabs / Roofs And Making Good The Damages By Bringing To The Original Condition To The Satisfaction Of The Engineer-In-Charge And Painting Two Coats Of Approved Shade ( Post Office Red ) Of Enamel Paint Over A Coat Of Approved Primer For Overheads Pipes 491 200Mm Jindal / Tata 492 150Mm 493 100 Mm 494 80 Mm 495 50 Mm 496 Providing, Installing And Commissioning C.I. Flanged Y Type Strainer With Ss Mesh, Suitable Flanges, Nuts, Bolts, Gaskets Etc. Complete ( Isi ) .200 Mmkartar / Zoloto / H Sarker / Eqv 497 Supply And Installation, Testing And Commissioningof Double Flanged Isolation Sluice Valves Conforming To Is 14846 Tested To Isi Marked , Pn 1.6 With Ci Body, Bonnet & Brass Trim Parts, & Having Necessary Companion Flanges, Bolts, Nuts, Gasket Packing, Support And Any Other Spares, Includingindicator For Open And Shut Position 498 Size :200 Mm Kartar / Kalpana / Eqv 499 Size :150 Mm Kartar / Kalpana / Eqv 500 Size :100 Mm Kartar / Kalpana / Eqv 501 Size :50 Mm Kartar / Klapana / Eqv 502 Supply, Installation, Testing And Commissioning Of Ci Butterfly Valve Of Pn 1.0 Rating With Metal Seat Duly Isi Marked Complete With Nuts, Bolts, Washers, Gaskets Conforming To Is 13095 Of Following Sizes As Required: 503 Size :150 Mmkartar / Kalpana / Eqv 504 Size :100 Mm Kartar / Kalpana / Eqv 505 Size :50 Mm Kartar / Kalpana / Eqv 506 Nrv Conforming To Is 5312 ( Swing Type ) Or To Api 594 / 598 ( Dual Plate Check Type ) With Ci Body & Brass Trim Part, Pn 1.6 Having Necessary Companion Flanges, Cs Hardwares. Gaskets, Arrow Indicating Direction Of Flow, Etc. Complete. It Shall Be Isi Marked And Approved Make 507 Size : 150 Mmkartar / Kalpana / Eqv 508 Size :50 Mmkartar / Kalpana / Eqv 509 Supply, Installation Testing And Commissioning Pressure Switch Assembly With Interlocking Of Pumps. Indfos / Danfos / Equivalent 510 100 Mm Dial Pressure Gauge With Syphon Tubing, Isolation Valve & Mounting Accessories Complete Range: 0 - 10 Kg / Sq.Cm.H-Guru / Waree / Fiebig 511 Supplying, Installing, Testing And Commissioning Of Hydraulically Operated Sprinkler Control Valve, With Water Motor Gong Bell And Trims As Required, Pressure Gauges, Drain Valves, Ball Valves, Check Valves, Strainers Etc. Complete.As Per Nbc / Lfa / Direction Of Engineer-In-Charge Size : 150 Mm.Hd / Viking / Tyco 512 Sitc Ofwater Level Indicator With Panel, With Probe & All Control Wiring To Operate The System Automatic / Manual & Shall Prevent The Pump From Dry Running As Per Nbc / Lfa / Direction Of Engineer-In-Charge 513 Ball Valve Of 15 Mm Diakartar / H Sarker / Eqv 514 ( A-5 ) Terrace Piping & Accessoriessupply, Installation, Testing And Commissioning Of Ci Butterfly Valve Of Pn 1.6 Rating With Metal Seat Duly Isi Marked Complete With Nuts, Bolts, Washers, Gaskets Conforming To Is 13095 Of Following Sizes As Required: 515 Size : 150 Mm 516 Size : 100 Mmkartar / H Sarker / Eqv 517 Nrv Conforming To Is 5312 ( Swing Type ) Or To Api 594 / 598 ( Dual Plate Check Type ) With Ci Body & Brass Trim Part, Pn 1.0 Having Necessary Companion Flanges, Cs Hardwares. Gaskets, Arrow Indicating Direction Of Flow, Etc. Complete. It Shall Be Isi Marked And Approved Make Size : 150 Mm Kartar / H Sarker / Eqv 518 100 Mm Dia Kartar / Kalpana / Eqv 519 Supplying, Installation Testing And Commissioning Of The Following ‘C’ Class Ms Pipe As Peris:1239 For Overhead Pipes With Flanges Welded And With Heavy Clamps , Hangers, Brackets Or Pipe Supports ( All With Screwed / Welded Joints ) As Required Including Pipe Of Shorter Lengths, Tapering Connecting Pieces, Short Or Long Bends, Ms Specials Like Sockets, Union Nuts, Elbows, Reducers, Plugs, Tees Etc. Complete To Make The System Operative As Required By Lfa / Tac Authorities The Pipes Will Have To Be Laid And Fixed In Trenches On Walls, Ceilings, Into Brick Walls Or Rcc With Lead Anchor Fasteners. The Work Shall Beto The Satisfaction Of The Engineer-In-Charge And Painting Two Coats Of Approved Shade ( Post Office Red ) Of Enamel Paint Over A Coat Of Approved Primer For Overhead Pipes 520 Size : 150 Mm Jindal / Tata 521 Size : 100 Mm Jindal / Tata 522 ( A-6 ) Sprinkler Systemsupplying, Installation Testing And Commissioning Of The Following‘C’ Class Ms Pipe As Peris:1239 For Overhead Pipes With Fittings & Flanges Including Pipe Of Shorter Lengths, Tapering Connecting Pieces, Short Or Long Bends, Ms Specials Like Sockets, Union Nuts, Elbows, Reducers, Plugs, Tees Etc. Complete To Make The System Operative As Required By Lfa / Tac Authorities The Pipes Will Have To Be Laid And Fixed In Trenches On Walls, Ceilings, Into Brick Walls Or Rcc With Lead Anchor Fasteners. The Work Shall Beto The Satisfaction Of The Engineer-In-Charge And Painting Two Coats Of Approved Shade ( Post Office Red ) Of Enamel Paint Over A Coat Of Approved Primer For Overhead Pipes. 523 Size : 150 Mm Jindal / Tata 524 Size : 100Mmindal / Tata 525 Size : 80 Mmindal / Tata 526 Size : 65 Mm Indal / Tata 527 Size : 50 Mmindal / Tata 528 Size : 40 Mmindal / Tata 529 Size : 32 Mmindal / Tata 530 Size : 25 Mmindal / Tata 531 Supplying, Installing, Testing And Commissioning Of Standard Response Sprinkler Quartzoid Bulb Type With 15Mm Screwed End Connection Of68 Deg. C. Temperature Rating, K 80 And Orifice Shall Not Be Less Than 3 Mm.Pendent Sprinkler Hd / Viking / Tyco 532 Supplying, Installing, Testing And Commissioning Oftest Valve And Complete Accessories Like Tees, Elbows Flanges Etc.As Per Nbc / Lfa / Direction Of Engineer-In-Charge. 533 Test Assembly 534 Test Valve ( 25 Mm ) 535 Drain Pipe Of 25 Mm Dia.Jindal / Tata / Eqv 536 Supply, Installation, Testing And Commissioning Of Ci Butterfly Valve Of Pn 1.6 Rating With Metal Seat Duly Isi Marked Complete With Nuts, Bolts, Washers, Gaskets Conforming To Is 13095 Of Following Sizes As Required: 537 Size : 150 Mmkartar / Zoloto / H Sarker / Eqv 538 50 Mm ( Drain Ball Type Valve For Each Riser / Drain Downtake ) Kartarzoloto / H Sarker 539 Supply & Installation Of Approved Make Flow Switch On Sprinkler Header On Each Floor, Operating At 24-V With All Accessories & Hardwares As Per Nbc / Lfa / Direction Of Engineer-In-Charge.Honeywell / Equivalent / Eqv 540 ( A-7 ) Signages Supplying Andinstalling Of In Position The Following Type Of Sign Boards Made Out Of 3Mm Thick Opaque Pvc Foam Board With Computer Cut, Pvc Reflective Self Adhesive Vinyle Painted Foam Board, Complete With Mirror Fasteners.Signage With PrintedIn Case Of Fire, Use Stairs Unless Instructed Otherwise Of 1.5Cm Height Letters In Red With White Back Ground. The Size Of The Board Shall Be 25Cm X 30 Cm And Shall Be Fixed At The Height Of 2 Mts. From Finished Floor Near Manual Call Points. 541 Floor Identification Signage ( I.E., Ground Floor …Etc. ) At Each Stair Enclosure On Every Floor, Indicating The Floor Number In Words, Lettering Size Shall Be 7.5 Cm With Contrasting Color From Back Ground. Size Shall Be 15Cm X 60Cm. 542 Fire Exit Signageat Each Stair On Every Floor, Indicating The Direction Of Fire Exit, Lettering Size Shall Be 7.5 Cm With Contrasting Color From Back Ground. Size Shall Be 15Cm X 60Cm. 543 Supplying And Installing Of In Position The Signages Fire Order It Should Contain The Following Matter On 3Mm Thick Opaque Pvc Foam Board Of Computerized Cut, Pvc Non-Reflective Self Adhesive Vinyle Painted Foam Board Of 3 X 4. As Per Bis Specification. A ) Alert The Security At Security Room By Actuating Manual Call Point Located At Strategic Locations. B ) Evacuate The Occupants By Using Fire Exits And Emergency Exits Only And Assemble At Various Assembly Points. ( C ) If Possible Try To Extinguish The Fire By Using Nearest / Suitable Portable Extinguisher Or Water From Nearest Wet Riser.D ) Be Calm And Do Not Give Any Room From Panic, Walk, Do Not Run. ( E ) If You Encounter Serious Difficulty In Evacuation, Flat And Try To Attract Attention Of Rescue Team. 544 B.Action By Security / Reception Upon Receipt Of Information Through Fire Alarm Or Fire Detectors Or By Using Public Address System. ( A ) Alert The Occupants By Using Public Address System. B ) Inform Fire Control Through Any One Of The Following Phone Numbers: 101 / ( Local Numbers ) C ) Refer Evacuation Plan From Evacuating Standard People. D ) Guide The Fire Force, On Their Arrival To The Seat Of Fire.E ) In Case Of The Casualties, Call Ambulance By Dialing Number……..Phone : -----------------------Fax : ---------------------------- As Per Bis Specification. 545 Supplying Andinstalling Of In Position The Following Type Of Sign Boards Made Out Of 3Mm Thick Opaque Pvc Foam Board With Computer Cut, Pvc Reflective Self Adhesive Vinyle Painted Foam Board, Complete With Mirror Fasteners. As Per Bis Specification. 546 Fire Hose Reel 547 Fire Extinguishers 548 Analogue Addressable Main Fire Alarm Panel 549 Sprinkler Control Valves 550 Mcp’S 551 ( B ) Analogue Addressable Fire Detection And Alarm Systemsupply, Installation, Testing And Commissioning Of Main Fire Alarm Control Panel ( Facp ) , The Panel Shall Be Addressable Analogue Fire Detection And Alarm Type With Capacity Of 2 Loops Complete With All Accessories And Battery Back Up For 48 Hours In Standby Mode And 15 Minutes In Alarm Condition. The Panel Shall Have Minimum Of 80 Character Lcd Display. Each Loop Shall Support 99 Analog / Addressable Devices And 99 Modules Minimum As System Capacity. The Panel Shall Have Tcp / Ip Facility. The Panel Shall Be As Per Technical Specification. The Panel Shall Be Ul / En / Fm Approved. The Quoted Rate Shall Inclusive Ofbacnet / Modbus Interface For Fire Alarm Panel With Complete Accessories. Honeywell / Cooper / Edward / Siemens / Ravel 552 Supply, Installation, Testing And Commissioning Of Analogue Addressable Multi Sensor Smoke, Heat Multi Criteria Detector With Standard Base And Other Accessories As Required. The Detector Shall Be Ul / En / Fm Approved.Honeywell / Cooper / Edward / Siemens / Ravel 553 Supplying, Installing, Testing And Commissioning Of Addressable Manual Call Pointwith Built In Monitor Module, All Accessories Etc., Complete. The Device Shall Be Ul / En / Fm Approved.Honeywell / Cooper / Edward / Siemens / Ravel 554 Supplying, Installing, Testing And Commissioning Of Isolator Module With All Accessories Etc., Complete. The Device Shall Be Ul / En / Fm Approved.Honeywell / Cooper / Edward / Siemens / Ravel 555 Supplying, Installing, Testing And Commissioning Of Addressable Monitor Module, All Accessories Etc., Complete. The Device Shall Be Ul / En / Fm Approved.Honeywell / Cooper / Edward / Siemens / Ravel 556 Supplying, Installing, Testing And Commissioning Of Addressable Hooter Cum Strobeat 85 Dba @ 3M For Audible Annunciation And 75Cd Flashing At 1 Hz For Visual Indication With All Accessories Etc., Complete. The Device Shall Be Ul / En / Fm Approved. Honeywell / Cooper / Edward / Siemens / Ravel 557 Supplying, Installing, Testing And Commissioning Of 2C X 1.5 Sq. Mm, Twisted Pair Pvc Insulated Frls Armored Cable With Accessories Confirming To Is Standards And Specifications. The Quoted Rate Shall Includes Ofacrylic Fire Stop Sealant In The Opening For Cablespassing Throughfire Compartment Walls Of Rcc Floors, Masonry Walls To Provide Up To 2 Hours Fire Rating.Polycab / Kei / Finolex / Havells / 558 ( C ) Emergency Evacuation System / Public Address System Supplying, Installing, Testing And Commissioning Of12 Watt Wallmounted Speakers With Built In Line Matching Transformer, Grill Flush Mounting Type In Side The Utility Rooms.Honeywell / Bosch / Ahuja / Ecler 559 Supplying, Installing, Testing And Commissioning Solid State Amplifier Of 450W Rms Out Put In Rack, Including Necessary Control Wires, Jocks Etc. Complete.Honeywell / Bosch / Ahuja / Ecler 560 Supplying, Installing, Testing And Commissioning Of P.A. Console 8 Zone Shall Expandable Up To 60 Zones , With Priority Module Micro Processor Based, Mixing Amplifier, With 6 Zone For Suitable Selection Module, Power Supply Unit & Goose Neck Micro Phone Etc.Honeywell / Bosch / Ahuja / Ecler 561 Supplying, Installing, Testing And Commissioning Of P.A. Call Station Of 8 Zones With Priority Module Micro Processor Based & Goose Neck Micro Phone Etc Shall Be Located In The Reception / Security For The Announcement Necessary Communication Cable / Cat 6 Shall Be Considered From Pa Controller To Call Station .Honeywell / Bosch / Ahuja / Ecler 562 Supplying, Installing, Testing And Commissioning Of 12 Rack 650Mm Depth, 16U High Amplifier Rack Assembly Made Of Aluminum Channel Equivalent To Euro Rack System, With Side And Rear Panels Made Of 14 Swg Powder Coated Sheet Steel Front Transparent Persplexdoor And With Rails, Rollers & Bearings. Fans Shall Provided At The Top For Ventilation Side Panels Will Be Ventilated Type. The Rack Shall Be Powder Coatedof Approved Color And Spare U Shall Be Covered With Blank Panels.Honeywell / Bosch / Ahuja / Ecler 563 Supplying, Installing, Testing And Commissioning Of 2 Runs Of 40 Strand And Each Of0.2 Mm Thick, Twisted Pair Pvc Insulated Frls Unarmored Cable With Accessories Confirming To Is Standards And Specifications. The Quoted Rate Shall Includes Ofacrylic Fire Stop Sealant In The Opening For Cablespassing Throughfire Compartment Walls Of Rcc Floors, Masonry Walls To Provide Up To 2 Hours Fire Rating. Polycab / Kei / Finolex / Havells 564 Supplying, Installing, Testing And Commissioning Approved Make Pvc Frls Conduits On Ceiling / Wall / Floor Etc. Complete With Accessories Like, Junction Boxes, Collars, Bends Etc. 20Mm Dia. 565 P.H. Worksupplying Allmaterials, Labour, T&P And Providing And Fixing To Wall Or Ceiling And Floor Pvc Pipes Confirming To Astm-D- 1785 / 89 ( Sch-80 ) And Pipe Fittings Of The Following Nominal Borewith Clamps Including Making Good The Wall, Ceiling And Floor, Testing All Complete As Per Specification And Direction Of The Engineer-In-Charge. 566 First Floor 567 20 Mm Cpvc ( Sdr-13.5 ) Pipes ( Oriplast / Supreme ) 568 25 Mm Cpvc ( Sdr-13.5 ) Pipes ( Oriplast / Supreme ) 569 32 Mm Cpvc Sdr-13.5 Pipes ( Oriplast / Supreme ) 570 40 Mm Cpvc Sdr-13.5 Pipes ( Oriplast / Supreme ) 571 50 Mm Upvc Sch-80 Pipes ( Oriplast / Supreme ) 572 Second Floor 573 20 Mm Cpvc ( Sdr-13.5 ) Pipes ( Oriplast / Supreme ) 574 25 Mm Cpvc ( Sdr-13.5 ) Pipes ( Oriplast / Supreme ) 575 32 Mm Cpvc Sdr-13.5 Pipes ( Oriplast / Supreme ) 576 40 Mm Cpvc Sdr-13.5 Pipes ( Oriplast / Supreme ) 577 50 Mm Upvc Sch-80 Pipes ( Oriplast / Supreme ) 578 Third Floor 579 20 Mm Cpvc ( Sdr-13.5 ) Pipes ( Oriplast / Supreme ) 580 25 Mm Cpvc ( Sdr-13.5 ) Pipes ( Oriplast / Supreme ) 581 32 Mm Cpvc Sdr-13.5 Pipes ( Oriplast / Supreme ) 582 40 Mm Cpvc Sdr-13.5 Pipes ( Oriplast / Supreme ) 583 50 Mm Upvc Sch-80 Pipes ( Oriplast / Supreme ) 584 Supplying All Materials, Labour, T&P And Cutting Holes Through Existing Brick Work Including Making Good The Damages In Cement Mortar ( 1:4 ) For Taking G.I. Pipes And Fittings / P.V.C. Pipes And Fittings Etc. All Complete As Per P.H. Specification And Direction Of Engineer-In-Charge. 585 First Floor :- 250 Mm Thick Wall 586 Second Floor :- 250 Mm Thick Wall 587 Third Floor :- 250 Mm Thick Wall 588 Supplying All Materials, Labour, T&P And Cutting Hole In R.C.C Floors, Roofs, Etc Upto 19 Cm Thickfor Passing G.I. Pipes / P.V.C Pipes And Fittings Etc And Repairing The Holes Afterinsertion Of Pipes Etc With Cement Concrete ( 1:2:4 ) Including Finishing Complete So As To Make It Leak Proof As Per Direction Of Theengineer-In-Charge. 589 First Floor :- 250 Mm Thick Wall 590 Second Floor :- 250 Mm Thick Wall 591 Third Floor :- 250 Mm Thick Wall 592 Supplying All Materials, Labour, T&P And Cutting Grooves In Pucca Floors And Walls For Taking G.I. / P.V.C. Pipes And Making Good The Damages As Per Direction Of The E.I.C. 593 First Floor 594 Second Floor 595 Third Floor 596 Supplying All Materials, Labour T&P And Fitting And Fixing Brass / Cp Fittings Of The Following Nominal Bore With Supply Of All Joiniting Materials Complete As Per Specification And Direction Of The Engineer-In-Charge. 597 Supplying All Materials, Labour, T&P And Fixing Standard Sized Two Waybib Cock Ofhindware / Jaquar / Parrywareof Approved Make Etc Complete Including Cutting The Wall And Making Good The Damages, Including Cost Of All Materials Complete As Per Ph Specification Complete As Per Direction Of Er-In-Charge. 15Mm Dia Cp Two Waybib Cock With Flange Jaquar Flr-Chr5053n. 598 Supplying All Materials, Labour, T&P And Fixing Standard Sizedbib Cock Ofhindware / Jaquar / Parrywareof Approved Make Etc Complete Including Cutting The Wall And Making Good The Damages, Including Cost Of All Materials Complete As Per Ph Specification Complete As Per Direction Of Er-In-Charge.15Mm Dia. Nominal Bore Long Body Bib Cock Jaquarflr-Chr5163 599 Supplying All Materials, Labour, T&P And Fixing Standard Sizedbib Cock Ofhindware / Jaquar / Parrywareof Approved Make Etc Complete Including Cutting The Wall And Making Good The Damages, Including Cost Of All Materials Complete As Per Ph Specification Complete As Per Direction Of Er-In-Charge.15Mm Dia. Nominal Bore Short Body Bib Cock Jaquarflr-Chr5037n 600 Supplying All Materials, Labour, T&P And Fixing Standard Sized15mm Dia Angular Stop Cock Of Hindware / Jaquar / Parrywareof Approved Make Etc Complete Including Cutting The Wall And Making Good The Damages, Including Cost Of All Materials Complete As Per Ph Specification Complete As Per Direction Of Er-In-Charge. 15Mm Dia Cp Angle Stop Cock With Wall Flange Jaquar Flr-Chr5053n 601 Supplying All Materials, Labour, T&P And Fixing Standard Sized Pillar Cock Of Hindware / Jaquar / Parryware Of Approved Make Etc Complete Including Cutting The Wall And Making Good The Damages, Including Cost Of All Materials Complete As Per Ph Specification And Direction Of Engineering-In-Charge. 15Mm Dia Brass Pillar Cock Jaquar Continental Cat. No.- -Jaquar Flr - Chr5011n 602 Fixing Of 25Mm Dia Brass / Gun Meta Ball Valve Confirming Tois : 781-1995 Of Approved Makeas Per Specification Complete As Per Direction Of Er-In-Charge.32Mm Dia Brass Or Gun Metal Full Way Valve ( Shakti Make ) 603 Fixing Of 32Mm Dia Brass / Gun Meta Ball Valve Confirming Tois : 781-1995 Of Approved Makeas Per Specification Complete As Per Direction Of Er-In-Charge.32Mm Dia Brass Or Gun Metal Full Way Valve ( Shakti Make ) 604 Fixing Of 40Mm Dia Brass / Gun Meta Ball Valve Confirming Tois : 781-1995 Ofof Approved Makeas Per Specification Complete As Per Direction Of Er-In-Charge.40Mm Dia Brass Or Gun Metal Full Way Valve ( Shakti Make ) 605 15Mm Dia Pvc Connection Pipe 450 Mm Long 606 15Mm Dia Cp Extention Nipple 607 Providing And Fixingcircular Type Stainless Steeljalli ( Grating ) With Hole For Floor / Nahani Trap Etc Complete As Per Specification And Direction Of The Engineer In Charge. 608 Supplying All Materials, Labour, T&P And Fixing Health Faucet Of Hindware / Jaquar / Parryware Complete With Chromium Plated Brass Brackets Fixed To Wooden Plugs With Chromium Plated Brass Screws As Per Specification And Direction Of Theengineer-In-Charge. 609 15Mm Dia Cp Health Faucet Of Jaquar 1.2Mtr Long, 8Mm Diajaquar Ald-Chr577. 610 Supplying All Materials, Labour, T&P And Fitting And Fixing U-Pvc Swr Soil Waste Ventilating Pipes And Fittings Of The Following Outside Diameter Conforming To Isi No 13592 / 1992 To Walls With Nails, Bobbins And Wooden Plugs Or Laying In Trenches Including Jointing With Supply Of Approved Rubber Lubricant By Non-Heat Application Method / As Per ManufacturerS Specification, Testing, Earthwork In Excavation In All Kinds Of Soil And Refilling Of Trenches As Per Specification And Direction Of The Engineer-In-Charge. 611 In Building 612 110Mm Diameter U-Pvc Swr Pipes ( Oriplast Type-B / Supreme ) 613 110Mm U-Pvcdoor Tee 614 110Mm U-Pvc Offset 615 110Mm U-Pvcdoor Bend 616 110Mm U-Pvcplain Shoe Bend 617 110Mm U-Pvcvent Cowl 618 110Mm P-Trap 619 110Mm U-Pvcplain Bend 620 100Mm S / S Coupling With Epmd 621 Supplying All Materials, Labour T&P And Cutting Holels Through Existing Brick Or Laterite Masonry Wall For Taking H.C.I Pipes And Fittings Including Making Good The Damages Etc. All Complete As Per P.H.Specification And Direction Of Theengineer-In-Charge. 622 250Mm To 375Mm Thick Wall 623 Supplying All Materials, Labour T&P And And Fixing 12.50 Liters / 10 Liters Capacity Low Level Flushing Cistern Of Hindware / Jaquar / Parryware With A Pair Of Cast Iron Or M.S. Brackets Complete With Fittings Such As Siphonic Arrangements 15Mm Nominal Size Brass / Pvc Ball Valve With Polythene Float Cp Brass Handle, Unions And Couplings For Connection With Inlet, Outlet And Overflow Pipes, 32Mm Dia Cp Long Flush Bend, 15Mm Dia Pvc Inlet Connection Pipe Including Cutting Holes And Making Good The Same And Connecting The Flush Bend With Cistern And Closet And Connceting The Inlet Pipe With Suupply Main Etc All Complete As Per The Specification And Direction Of The Engineer-In-Charge. 624 10 Liters Capacity Pvc Cistern With 32Mm Dia Flush Bend.Hindware Sleek Fresh Single Flushstarwhite, Size 47.6 X 15.5 X 32.5 Cm 625 Supplying All Materials, Labour, T&P And Fixing Vitreous China Water Closet, Squatting Pan ( Indian Type W.C Pan / Orissa Pattern Squatting Pan ) Of Hindware / Jaquar / Parryware Duly Embedded In Cement Concrete ( 1:4:8 ) Using 4Cm Size Hard Granite Metal Including Fixing A Pair Of Vitreous China 250Mm X 130Mm X30mm Footrest, Fixing 100Mm Dia Hci P Or S Trap ( With / Without 50Mm Dia Horn ) For Water Colset Squatting Pan Including Jointing The Trap With Pan In Cement Mortar ( 1:1 ) Cutting The Floor And Mending Good The Damages Etc All Complete As Per Specification And Direction Of Theengineer-In-Charge. 626 Hindware Orissa Pan Cat No 20004 Starwhite. Size- 53X41 Cm 627 Supplying All Materials, Labour, T&P And Fixing The Following Vitreous China Wash Down Water Closet ( European Type W.C. Pan ) Of Hindware / Jaquar / Parryware With Integral P Or S Trap To The Floor With Wooden Plug And Chromium Plated Pedestal Screws Including Jointing The Trap With Soil Pipe In Cement Mortar ( 1:1 ) Fixing Plastic Seat And Cover For Wash Down Water Closet With Chromium Plated Brass Hinges And Rubber Buffers Including Polishing Etc All Complete As Per Specification And Direction Of Theengineer-In-Charge. 628 Ewc With P / S Trap Plain Fls-Wht-5351 / 5201 ( S-10 ) Starwhite Type, Size-370X650x765 Mm, 629 Supplying All Materials, Labour T&P And Fixing Wash Basins Of Hindware / Jaquar / Parryware With Hole For Pillar Taps With Cast Iron Or M.S.Brackets Painted White Including Cutting Holes In Walls And Making Good The Damages With Supply Of Wooden Plugs, Screws And Cement Etc, Fixing Pedestal For Wash Basin Recessed At The Back For The Reception Of Pipes And Fittings, Fixing Pvc Waste Pipe Of 32Mm Nominal Diameter For Wash Basin Including Brass Check Nut Complete, Fixing Pillar Taps Capstan Head Screw Down High Pressure Lettered Hot And Cold With Long Screws, Shanks And Back Nuts Of 15Mm Dia Nominal Bore, Fixing 15Mm Dia Pvc Inlet Connection Pipe And Making Connection With Pillar Cocks And Supply Mains For Wash Basin, Fixing 32Mm Dia Cp Brass Waste, Etc All Complete As Per Specification And Direction Of Theengineer-In-Charge. 630 Jaquar Wall Hungwash Basin Size - 565Mmx440x210mm, Cat -No- Fls-Wht-5801 / 5301Starwhite. 631 Countersunk Wash Basin 632 Supplying All Materials, Labour T&P And Fixing Counter Sunk Wash Basin Size - 545Mmx545x180mm, Cat.No. Fls-Wht-5951 With All Fittings As Per Direction Of The Engineer-In -Charge. 633 Supplying All Materials, Labour, T&P And Fixing Flat Back Large Pattern Urinal Of Hindware / Jaquar / Parryware The Following Sizes Including Connecting The Urinal With 32Mm Dia Pvc Waste Pipe 910Mm Long By Means Of White Lead Mixed With Chopped Hemp, Fixing 32Mm Dia Cp Dome Waste, 15Mm Dia Cp Spreader Including Cutting Holes In Walls Land Making Good The Damages With Supply Of Wooden Plugs, Screws And Cement Etc All Complete As Per Specification And Direction Of The Engineer In Charge. Hindware Flat Back Large Urinal Cat No-60002 Starwhite, Size-37.5X39x59 Cm. 634 Supply And Fixing All Materials, Labour, T & P And Providing Urinal Partition With Italian Collection ( Pastel ) - Size- 75X16.5X36.5 Cm Cat No-61005 Etc All Complete As Per Direction Of The Engineer-In-Charge. Make-Hindware. 635 Supplying All Materials, Labour, T&P And Fixing Mirror Of Superior Glass Mounted On 6Mm Thick A.C.Sheet Or Plywood Sheet And Fixed To Wooden Plugs With Cp Screws And Washers Complete As Per Specification And Direction Of The Engineer-In-Charge. 636 750Mmx600mm Size B.E.Mirror ( Alpina / Golden Fish / Belgion ) 637 Supplying All Materials, Labour, T&P And Fixing Standard Size Glass-Shelf Of Hindware / Jaquar / Parryware With Cp Brass Brackets And Guard Rails Complete Fixed To Wooden Plugs With Cp Screws As Per Specification Anddirection Of The Engineer-In-Charge. 638 Jaquar Glass Shelf Acn-Chr1171 N 600Mm Long 639 Supplying All Materials, Labour, T&P And Fixing Standard Sized Cp Towel Rail24Of Hindware / Jaquar / Parryware Complete Withcp Brass Brackets Fixed To Wooden Plugs With Cp Screws As Per Specification And Direction Of The Engineer-In-Charge 640 25Mmx600mm Long Cp Towel Rail ( Jaguar Make ) Acn-Chr1111nm. 641 Supplying All Materials, Labour, T&P And Fixing Standard Sizedchromium Plated Brasstowel Ring Complete With Chromium Plated Brassbrackets Fixed To Wooden Plugs With Chromium Plated Brassscrews As Per Specification And Direction Of The Engineer In Charge 642 Supplying All Materials, Labour, T&P And Fixing Standard Sizedchromium Plated Soap Case Ofhindware / Jaquar / Parryware Complete With Chromium Plated Brassbrackets Fixed To Wooden Plugs With Chromium Plated Brassscrews As Per Specification And Direction Of The Engineer In Charge 643 Cp Soap Holder ( Jaguar Make ) Acn-Chr1131n. 644 Supplying All Materials, Labour, T&P And Fixing Standard Sized Robe Hook Ofhindware / Jaquar / Parryware Complete With All As Per Specification And Direction Of The Engineer In Charge. Jaquar Robe Hook Akp-Abr-35791Pmi. 645 Supplying All Materials, Labour, T&P And Fixing Standard Sized Soap Dispensor Ofhindware / Jaquar / Parryware Complete With All As Per Specification And Direction Of The Engineer In Charge. Soap Dispense With Glass Bottle. Can-Chr1135n. 646 Providing And Fixing Salem Stainless Steel A Isi ( 18 / 8 ) Kitchen Sink As Per Is : 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required. A ) Kitchen Sink With Drain Board Nirali Makesize 510 X 1040 Mm Bowl Depth 178 Mm.600X450x250 647 Supplying & Fixing Of Matrix Set-1 Mat Code-70002, Ewc : ( P-18 ) ( Wb 46X36 With One Pair Mounting Brackets, Ewc & Cistern Complete With Fittings & Seat Cover, One No Hinged Rail 76 Cm And 4 Nos Of Grab Rail 60Cm Complete With All As Per Specification & Direction Of The Engineer In Charge. 648 Supply All Materials, Labour, T&P And Providing Fitting & Fixing ( Aqua Guard ) Pure Chill 80 Pss Uv Of Size 750X570x1350 Mm Height With Water Storage Capacity 120 Liters Along With 2 Nos Of Fancets 1 For Cold Water And 1 For Normal Water Including A Flow Of 1.5 Ltr Per Minute Etc. All Complete As Per Approved Drawing, Specification And Direction Of The Eic. 649 Supplying All Materials, Labour, T&P And Fixing100 Mm Dia Wall Mounted Over Head Shower& Shower Armhindware / Jaquar / Parryware Including Cutting The Wall And Making Good The Damages, Including Cost Of All Materials Complete As Per Ph Specification And Direction Of Engineer-In-Charge. 100 Mm Dia Cp Overhead Shower With Arm ( Jaquar -Ohsc-1989, Jaquar Shac 483 ) 650 Supplying All Materials, Labour, T&P And Fixing Standard Sized15mm Dia Single Lever Concealed Deusch Mixer With Provision For Connection To Overhead Shower Onlyof Hindware / Jaquar / Parrywareof Approved Make Etc Complete Including Cutting The Wall And Making Good The Damages, Including Cost Of All Materials Complete As Per Ph Specification Complete As Per Direction Of Er-In-Charge. Concealed Stop Cock Jaquar Flr-Chr5227. 651 Toilet Portion Civil Works 652 Supplying All Materials, Labour, T&P And Providing Mat Finish Tiles In Floors, Treads And Landing On 20Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement:4 Sand ) Joined With Neat Cement Slurry Mixed With Pigment To Match The Shades Of The Tiles Including Rubbing And Polishing Complete As Per Direction Of The Engineer In Charge. ( Tile 600Cmx600cm Kajaria- Fogparla Or Equivalent Makelto Be Pre-Approved By The Engineer In Charge ) 653 First Floor 654 Second Floor 655 Third Floor 656 Supplying All Materials, Labour, T&P And Fixing Provide Glazed Tiles In Dados Skirting On 12Mm Thick Cement Plaster ( 1:3 ) Jointed With Neat Cement Slurry Mixed With Pigments To Match The Shades Of The Tiles Including Rubbing And Polishing Complete As Per Direction Of The Engineer In Charge.Tile 600X300cm Sizekajaria-Duren Marfil Or Equivalent Make To Be Pre-Approved By The Engineer In Charge ) 657 First Floor 658 Second Floor 659 Third Floor 660 Supplying All Materials, Labour, T&P And Providing Cement Concrete ( 1:2:4 ) With 12Mm Size Hard Granite Chips Including Watering, Curing, Conveyance Of All Materials To Worksite, Payment Of Royalty, Taxes Etc All Complete As Per Specification And Direction Of The Engineer In Charge 661 First Floor 662 Second Floor 663 Third Floor 664 Factory Made Single Leaf Rigid Frp ( Alternately Called Grp ) Sandwich Composite Door Shutter Of 32Mm Thick Laminated With Two Grp Skins With Wood Grain Finish Fabricated Using Uv-Stabilised Isopthalic Gelcoat And One Layer Of 450 Gsm E-Glass Chopped Strand Mat ( Csm ) Impregnated With Orthopthalic Palyester Resin. The Thickness Of The Skins Shall Not Be Less Than 3.00Mm Expanded Polystyrone ( Eps ) Structural Foam Panel Of 29Mm Thickness And A Density Of 20Kg / Cu.Mtr Shall Be Used As Core Material. Wooden Reinforcements Made Of Seasoned Sal Wood Block Of Cross Section Not Less Than 28Mmx32mm And Also Necessary Sal Wood Reinforcements For Fitting The Metal Fittings Such As Tower Bolts, Aldrops, Handles Etc Shall Be Provided. A Structural Adhesive Compatible With ( Eps ) Foam Shall Be Used For Bending The Core Material, The Sal Wood Reiforcements And The Skins. The Material And Process For Manufacturing The Door Shutters Shall Conform To Rv-Tifac Composites Design CentreS Standards And Specifications And The Door Shutters Tested In Conformation To Is: 4020-1998. The Finish Of Door Shutter Will Be Plain Colour White / Ivory / Beige / Light Grey / Mahogany / Teak Wood Or Any Other Colour Using High Quality Pigments. Three Heavy Whight Mild Steel Butt Hinges Type-I ( Isi Marked ) Size 100Mm Are To Be Fitted On One Side Of Shutter With Frp Frame Of Size 45X90mm. ( Darwaja / Exon Door Make ) 665 First Floor, Second Floor, Third Floor 666 External P.H. & Sanitary Work 667 Supplying All Materials, Labour, T & P And Constructing Gully Trap Chamber Of The Following Inside Size With 8 Cm Thick R.C.C. Precast Cover Slab In Cc ( 1:2:4 ) Mix Using 12Mm Size H.G. Chips, Foundation Concrete ( 1:4:8 ) Using 40Mm Size H.G. Metal On Bed Aound Trap , Fly Ash Brickwork In Cm ( 1:6 ) In P&F And Inside 12Mm Thick Cement Plastering ( 1:3 ) Finished With A Floating Coat Of Neat Cement Including Fixing 100Mm X100mm Size Gully Trap, 150Mm X150mm C.I Gratig Etc. All Complete As Per Aproved Drawing, Specification And Direction Of Engineer-In-Charge. 668 250Mmx250mm With Rcc Cover 669 Supplying All Materials, Labour, T & P And Constructing Inspection Chamber Of The Following Inside Size With Cc ( 1:3:6 ) Mix Using 40Mm Size H.G. Metal On Bed, Ist Class Fly Ash Brickwork In Cm ( 1:6 ) , Moulding And Shaping The Channel Inside And Benching With Cc ( 1:2:4 ) Using 12Mm Size H.G. Chips, 12Mm Thick Cement Plastering ( 1:3 ) Finished With Punning To Inside , Cement Flush Pointing ( 1:3 ) To Outside , R.C.C. Cover Slab In ( 1:2:4 ) Using 12Mm Size H.G. Chips With Rcc Man Hole Cover , Earth Work In Excavation In All Kinds Of Soil And Refilling The Cavity Around The Chamber Including Watering , Curing, Conveyance Of All Materials To Worksite , Payment Of Royality , Taxesetc. All Complete As Per Aproved Drawing , Specification And Direction Of Engineer-In-Charge. 670 Inside Size 760Mm X760mm X450mm 671 Supplying All Materials, Labour, T&P And Laying In Trenches ( To Level Or Slope ) Unplasticized Pvc Pipes Conforming To Is: 4985 / 2000 Of The Following Outside Dia For Class-3 ( 0.60Mpa ) Including Jointing With Supply Of Approved Solvent Cement By Non-Heat Application Method / As Per Manufacturer’S Specification, Providing And Laying In Trench Cement Concrete ( 1:4:8 ) With 40Mm Size Hard Granite Metal In The Type C-1 Standard Bedding Surrounding Or Encasingincluding Concrete For Bedding And Curing Etc All Complete As Per Ph Specification And Direction Of The Engineer-In-Charge. 672 110Mm Dia U-Pvc Pipe Alround Concrete 673 160Mm Dia U-Pvc Pipe Alround Concrete 674 Supplying All Materials, Labour, T&P And Constructing Man Hole Chamber Of The Following Size Withcement Concrete ( 1:3:6 ) Using 40 Mm Size Hg Metal On Bed , !St Class Fly Ash Brick Work In Cm ( 1:6 ) Moulding And Shaping The Channel Inside And Benching With Cc ( 1:2:4 ) Mix Using 12 Mm Size H.G Chips, 12 Mm Thick Cement Plaster ( 1:3 ) With Punning To Inside, Cement Flush Pointing ( 1:3 ) To Outside , Rcc Cover Slab In ( 1:2:4 ) Mix Using 12 Mm Size H.G Chips With Rcc Man Hole Cover , Earth Work In All Kinds Of Soil And Refilling The Cavity Around The Camber Including Watering, Curing, Conveyance Of All Materials To Worksitepaymentof Royalty, Taxes Etc. All Completed As Per Approved Drawing, Specification And Direction Of Engineer-In-Charge. 675 Inside Size 910Mmx910mmx910mm 676 Addl Depth Of 0.30M Upto 4.50M Depth 677 Supplying All Materials, Labour, T&P And Constructing Soakway Pit Of The Following Size With Precast Rcc Rings Joined Loose, Gravel Backing In The Rear Of Well Steining, Precast Rcc Cover Slab In Cement Concrete ( 1:2:4 ) Using 12Mm Size Hg Chips Fitted With Iron Lifting Handles Including Cutting Hole In The Rings For Inlet Pipe, Earthwork In Open Well Excavation In All Kinds Of Soil And Refilling Of Cavity Around The Pit & Painting The Iron Works, Watering, Curing, Conveyance Of All Materials To Worksite, Payment Of Royalty, Taxes Etc All Complete As Per Approved Specification And Direction Of The Engineer-In-Charge 678 Rcc Rings Soakway Pit 1.22M Dia X 2.0M Deep 679 Supplying All Materials, Labour, T&P And Constructing Soakway Pit Of The Following Size With Dry Brick Walling From Bottom Upto Invert Of Inlet Pipe And 1St Class K.B Brickwork In Cement Mortar ( 1:6 ) For The Remaining Height At Top, Cement Concrete ( 1:4:8 ) Using 40Mm Size Hg Chips On Bed, 12Mm Thick Cement Plaster ( 1:4 ) Inside And Outside Over Masonry Brickwork, Gravel Backing In The Rear Of Well Steining, Rcc Cover Slab In Cement Concrete ( 1:2:4 ) Using 12Mm Size Hg Chips Fitted With Iron Lifting Handles Including Earthwork In Open Well Excavation In All Kinds Of Soil And Refilling Of Cavity Around The Pit & Painting The Iron Works, Watering, Curing, Conveyance Of All Materials To Worksite, Payment Of Royalty, Taxes Etc All Complete As Per Approved Specification And Direction Of The Engineer In Charge 680 Brick Masonry Soakway Pit 1.20M Dia X 2.00M Deep 681 Borewell 682 Construction Of 1 No Production Wells Including Scientific Source Finding Through Consolidated And Unconsolidated Rock With Down The Hammer Drilling Rig Or Combination Rig With Pvc Pipe And Installation Of Submersible Pump Set With All Acessories 683 Labour For Drilling A Perfectly Vertical Bore Hole Of Specified Dia For A Specified Depth Below Ground Level Through Consolidated And Unconsolidated Rock With Down The Hole Hammer Drilling Rig Or Combination Rig As Required To Suit The Site Condition As Per The Direction Of The Engineer In Charge Including Use Of Own Rig With Its Accessories, Tools And Plant And Consumables Etc For Lowering Of 200Mm / 150Mm Dia G.I / P.V.C / M.S Casing Pipes For Housing Fitted With Socket And With Or Without Well Screen As Per The Necessity For Soft, Medium, Hard And Boulder Formation ( G.I / P.V.C / M.S Casing Pipes If Required To Prevent Collapse Of Overburden Is To Be Provided By The Contractor Including Lowering And Withdrawing After Completion Of The Tube Well ) , 200Mm Dia To 400Mm Dia In Overburden Portion Including Packing Of Gravel Supplied By The Contractor For 400Mm Dia Bore Only 684 Drilling Of 200Mm Dia Bore 685 00 Mtr To 30Mtr 686 30 Mtr To 45Mtr 687 Drilling Of 150Mm Dia Bore 688 45 Mtr To Above 689 Lowering The Following Size Of G.I / P.V.C / M.S Housing Pipes With Or Without Slotted Pipes As Per The Necessity From Ground Level Up To 45.00M Depth And Fitted And Fixed Up In Perfectly Vertical Position Including Cutting And Threading Of Pipes And Slotted Pipes And Supplying And Fixing All Jointing Materials, Tools And Plant Etc All Complete And Keeping The Top Of Casing Pipe Threaded Including Plugging Tube Wells To Prevent Entry Of Foreign Materials. 690 Lowering Of 200Mm Dia P.V.C Casing Pipes 691 00 Mtr To 30Mtr 692 30 Mtr To 45Mtr 693 Supplying Polyvinyl Chloride Pipes As Per Astm-D-1785-89 Having Threads In Accordance With Din 2999 Part-1 / Din-42225 Part-Ii Specification Length Of Pipe ( Laying Length ) Will Be 3 Mtrs. The Pipes Shall Be Supplied With Both External And Threaded With Free Socket. The Pipe Having External Thread At One End I.E Female And Or Belled End. The Female End Having Internal Thread Is To Be Belled In Order To Accept The Male End While Jointing Pipes With A Bore Threading Shall Be Provided With A Greave At The Roof Of The Male Thread Accomodate Flexible Pvc / Rubber O Ring To Make The Joint Water Tight Colour Of The Pipe Shall Be Blue. The Name Of The Manufacture Along With Batch No Class Of Pipe Shall Be Stranded Legibly Of Each Pipe Length. 694 200Mm Dia Pvc ( Sch-80 ) Pipe 695 Supplying All Materials, Labour, T&P And Providing And Providing Sanitary Sealing By Cement Concrete Grouting Of Annular Space Around Gi / Pvc / Ms Housing Pipe Upto 5M Below Ground Level ( As Per Drawing ) To Plug The Bore Hole Excluding Cost Of Cement All Complete As Per Direction Of The Engineer In Charge. Minimum One Metre Of Casing Pipe To Be Inserted In The Bore Into The Rock At The Bottom To Ensure Sanitary Sealing ( Excluding Cost Of Cement Which Will Be Supplied Directly By The Department ) 696 Cleaning And Developing The Tube Well With Supply Of Compressor Worked Till Clear And Adequate Discharge Is Obtained From The Tube Well Including Supply And Use Of All Necessary Equipment And Labour As Per Direction Of The Engineer In Charge 697 By Dth Rig 698 Supplying All Materials, Labour, T&P And Providing, Fitting And Fixing Submersible Pump With Squirrel Cage Induction Type Submersible Type Submersible Electric Motor To Run On 3 Phase / 1 Phase Line Voltage Ranging From 320 Volt To 450 Volt Conforming To Is: 8034 / 89 With Following Specifications With Suitable Control Panel, Jointing With Gi / Pvc / Hdpe Pipes, Electrification, Testing, Commissioning, Trial Running, Conveyance Of All Materials To Worksite, Payment Of Taxes Etc All Complete As Per Specification And Direction Of The Engineer In Charge ( Texmo / Crompton Greaves / Kirloskar Make ) 699 1 H.P. Single Phase / Three Phase 3 Stagehead Renge Of 20 To 35 Mtr With Discharge Capasity 145 To 110 L.P.M With Outlet Dia 25 Mm ( Keeping 100% Standby ) 700 Dol Control Panel 701 40Mm Dia Steel Short Piece 702 Well Cap 703 50Mm Size Ci Bracket 704 2.50Sqmm Flat Cable 705 20Mm Dia Rigid Upvc Pipes 706 Steel Rope With Cover 707 Labour Charges For Lowering Including Transportation 708 Supplying All Materials, Labour, T&P And Providing And Fixing To Wall Or Ceiling And Floor Hdpe Pipes And Pipe Fittings Conforming To Is: 4984 / 2000 ( 10Kgf / Sqcm ) Of The Following Nominal Bore With Clamps And Jointing By Fusion Welding Method Including Testing, Making Good The Wall, Ceilingand Floor All Complete As Per Specification And Direction Of The Engineer In Charge 709 32Mm Hdpe Pipes ( Finolex / Supreme Make ) 710 B.Ii- Septic Tank. ( 200 User ) ( 10X4x2 ) Mtr 711 Earthwork In Excavation In All Types Of Soil For Site Leveling, Foundation, Pits, Trenches And Other Civil Works Up To And Including 1.5 Metre Lift And Stacking The Soil Upto A Lead Of 100 Metre And Including Dewatering, Removing Slush, Shoring And Strutting ( As Required ) , Complete As Per Specification And As Directed By The Engineer-In-Charge. 712 All Type Of Soil 713 Filling At All Depth With Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 15 Cm In Depth : Consolidating Each Deposited Layer By Ramming And Watering Complete ( Lead Upto 100M ) As Directed By The Engineer-In-Charge. 714 S. Tank 715 Supplying Offilling Sand In Foundation And Over Areas Including Watering, Ramming, Consolidating And Dressing, Labours, Tools, Taxes Etc. All Complete As Per The Specification And Direction Of E.I.C. 716 S. Tank 717 Providing And Laying Plain Cement Concrete 1:3:6 ( 1 Cement:3 Sand: 6 Stone Agregate 40Mm Nominal Size ) As Levelling Course In Foundation And Plinth Etc. Includingtempering, Curring, Shuttering Etc. Complete All Depth And Height. 718 S. Tank 719 Supplying All Materials, Labour, T&P And Providing Cement Concrete ( 1:2:4 ) With 12M Size Hard Broken Granite Chips Including Watering, Curing, Conveyance Of All Materials To Worksite, Payment Of Royalty, Taxes Etc All Complete As Per Specification And Direction Of The Engineer In Charge 720 S. Tank 721 Providing, Lifting, Hoisting And Laying Reinforced Cement Concrete Of M-250 Grade As Per Approved Designs And Drawings Having A Minimum Compressive Strength ( In Work Test ) 250 Kg. / Square Cm. In 15 Cm. Cubes At 28 Days After Mixing And Test Conducted In Accordance With I.S. 516 Using 12 Mm. To 20 Mm. Size Black Hard Crushed Broken Granite Stone Chips And Screened And Washed Sharp Sand For Mortar Of Approved Quality From Approved Quarry, Washed Andcleaned ( 20Mm. Size Chips Not To Exceeds 25 % ) To Be Mixed In Concrete Mixture With Portlandslag Cement ( Psc ) Including Hoisting, Lowering, Laying And Compaction Concrete By Using Vibrators, Watering And Curing For 28 Days, Centering And Shuttering Then After Dismantling And Removing Debris From The Work Site And Finishing The Exposed Surface Smooth Providing Grooves Or Beads Wherever Necessary Including Cost, Conveyance, Loading, Unloading, Royalties And Taxes Of All Materials And Cost Of All Labours, Sundries, T & P Required Of The Work Etc. Complete In All Respect As Directed By The Engineer-In-Charge. But Excluding Cost And Conveyance Of M.S. Rods Or Tor Steel And Binding Wires And Labour Charges For Straightening, Cutting, Bending Etc. Of M.S. Rods Or Tor Steel Tying The Grills And Placing In Proper Position. 722 A ) Base 723 B ) Wall / Beam 724 C ) Slab 725 Supplying, Straightening, Cutting, Bending, Placing In Position And Binding Reinforcement Steel Work In Rcc / Reinforced Brick Works As Per Drawing And Specification Including Preparation Of Respective Bar Bending Schedule And Binding ( Binding Wire To Be Used As Per The Is Code ) Etc. All Complete As Per Direction Of Engineer-In-Charge.Cold Twisted Bars, Thermo-Mechanically-Treated Bars. 726 Steel 727 Fly Ash Bricks Masinary ( 1:6 ) ( In F & P ) . 728 First Class Fly Ash Brick Masonry Usingf.A. Bricks Of Size 25 Cm. X 12 Cm. X 8 Cm. Having Crushing Strength Not Less Than 75 Kg. Per. Sqr. Cm. In Cement Mortar Of Mix ( 1:6 ) With Ordinary Portland Slag Cement ( Psc ) And Screened & Washed Sand For Mortar After Immersing The Bricks For 6 ( Six ) Hours In Water Before Use In Foundation & Plinth Including Splays Cutting, Circular Moulding, Corbelling, Chamfering And Similar Such Type Of Works, Watering And Curing Etc. Including Cost, Conveyance, Loading, Unloading, Royalties And Taxes Of All Materials, Cost Of All Labour, Scaffolding, Sundries, T&P Required For The Works Etc. Complete In All Respect As Directed By The Engineer-In-Charge. 729 Brick Work In Inlet & Outlet Chamber 730 12Mm Cement Plaster On Internal Smooth Side Of Rcc / Brick Surfaces With Cement Mortar Of Mix 1:4 ( 1 Cement : 4 Fine Sand ) Including Neat Cement Punning & Necessary Scaffolding, Curing Etc. All Complete At All Floors And All Heights. 731 Plaster In Inlet & Outlet Chamber 732 16 Mm Plastering. 733 Providing 16Mm. Thick Cement Plaster In All Floors At All Height With Cement Mortar Of Mix ( 1:6 ) With Opc 53 Grade Cement Finished Smooth To Inside Smooth Surface Of Brick Masonry Walls After Racking Out The Joints Including Watering And Curing, Rounding Of Corners Etc. Complete With Cost, Coveyance, Loading And Unloading, Royalties And Taxes Of All Materials And Cost Of All Labours, Sundries, T&P And Scaffolding Required For The Work Etc. Complete In All Respect As Desired By The Engineer In Charge. 734 Plaster In Inlet & Outlet Chamber 735 Supplying All Materials, Labour, T&P And Providing , Fitting & Fixing 100Mm X100mm X100 Mm Sw Tee In Wall Including Filling The Recess With Cement Concrete ( 1:3:6 ) With 12Mm Size H.G Chips All Complete Including Watering, Curing, Conveyance Of All Materials To Worksite, Payment Of Royalty All Complete As Per Specification And Direction Of The Engineer In Charge. 736 Sw Tee 737 Supplying All Materials , Labour, T&P And Making Ms Step Iron In 20Mm Diameter Ms Steel Bars & Fixing Into Walls Of Man Hole / Septic Tank Duly Embedded In Cement Concrete ( 1:3:6 ) Complete As Per Specification And Direction Of The Engineer In Charge. 738 Ms Steps Irons 739 Oh Tank ( 20Kld ) 740 Providing, Lifting, Hoisting And Laying Reinforced Cement Concrete Of M-250 Grade As Per Approved Designs And Drawings Having A Minimum Compressive Strength ( In Work Test ) 250 Kg. / Square Cm. In 15 Cm. Cubes At 28 Days After Mixing And Test Conducted In Accordance With I.S. 516 Using 12 Mm. To 20 Mm. Size Black Hard Crushed Broken Granite Stone Chips And Screened And Washed Sharp Sand For Mortar Of Approved Quality From Approved Quarry, Washed Andcleaned ( 20Mm. Size Chips Not To Exceeds 25 % ) To Be Mixed In Concrete Mixture With Portlandslag Cement ( Psc ) Including Hoisting, Lowering, Laying And Compaction Concrete By Using Vibrators, Watering And Curing For 28 Days, Centering And Shuttering Then After Dismantling And Removing Debris From The Work Site And Finishing The Exposed Surface Smooth Providing Grooves Or Beads Wherever Necessary Including Cost, Conveyance, Loading, Unloading, Royalties And Taxes Of All Materials And Cost Of All Labours, Sundries, T & P Required Of The Work Etc. Complete In All Respect As Directed By The Engineer-In-Charge. But Excluding Cost And Conveyance Of M.S. Rods Or Tor Steel And Binding Wires And Labour Charges For Straightening, Cutting, Bending Etc. Of M.S. Rods Or Tor Steel Tying The Grills And Placing In Proper Position. 741 B ) Wall, Beam & Column 742 C ) Slab 743 Supplying, Straightening, Cutting, Bending, Placing In Position And Binding Reinforcement Steel Work In Rcc / Reinforced Brick Works As Per Drawing And Specification Including Preparation Of Respective Bar Bending Schedule And Binding ( Binding Wire To Be Used As Per The Is Code ) Etc. All Complete As Per Direction Of Engineer-In-Charge.Cold Twisted Bars, Thermo-Mechanically-Treated Bars. 744 B ) Wall, Beam , Column & Slab 745 6 Mm Cement Plaster On Internal Smooth Side Of Rcc / Brick Surfaces With Cement Mortar Of Mix 1:4 ( 1 Cement : 4Fine Sand ) Including Necessary Scaffolding, Curing Etc. All Complete At All Floors And All Heights. 746 Supplying All Materials, Labour, T&P And Providing Pidifin 2K Including Conveyance Of All Materials To Worksite, Payment Of Royalty, Taxes Etc All Complete As Per Specification And Direction Of The Engineer In Charge 747 Supplying All Materials, Labour, T&P And Providing Cement Punning Including Watering, Curring And Conveyance Of All Materials To Site. 748 Supplying And Fitting And Fixing Stainless Steel 34 Grade In Said Rail Using 5Mm Dia 2Mm Thick Circular Pipe And Balustrade 32Mm X 32Mm X 2Mm Below Including Welding Welding With Stainless Steel Elect Rod And Fixing With Necessary Accessories Ete. Complete As Per Direction Of The Engineer-In-Charge. 749 Providing Fitting And Fixing Ms Cover Made Out Of Ms Angle And Sheet Duly Welding And Fixing With Frame And Hinges Along With Locking Arrangement Of Size 60Cmx60cm Etc Complete As Per Direction Of Engineer -In-Charge. 750 Mh Cover 751 Rainwater Harvesting Work. ( Two Nos ) 752 Earthwork In Excavation Over Areas ( Exceeding 30 Cm In Depth 1.5 M. In Width As Well As 10 Sqm On Plan ) Including Disposal Of Excavated Earth Lead Upto 100M And Lift Upto 1.5 M, Disposed Earth To Be Levelled And Neatly Dressed As Directed By The Engineer-In-Charge. 753 Supplying, Filling, Spreading & Leveling Stone Boulders Of Size Range 50Mm To 200Mm, In Recharge Pit, In The Required Thickness, For All Leads & Lifts, All Complete As Direction Of Engineer-In-Charge. 754 Supplying, Filling, Spreading & Leveling Gravels Of Size Range 5Mm To 10Mm, In Recharge Pit, Over The Existing Layar Of Boulders, In The Required Thickness, For All Leads & Lifts, All Complete As Direction Of Engineer-In-Charge. 755 Supplying, Filling, Spreading & Leveling Coarse Sand Of Size Range 1.5Mm To 2Mm, In Recharge Pit, Over The Existing Layar Of Gravels Layer, In The Required Thickness, For All Leads & Lifts, All Complete As Direction Of Engineer-In-Charge. 756 Providing, Lifting, Hoisting And Laying Reinforced Cement Concrete Of M-200 Grade As Per Approved Designs And Drawings Having A Minimum Compressive Strength ( In Work Test ) 200 Kg. / Square Cm. In 15 Cm. Cubes At 28 Days After Mixing And Test Conducted In Accordance With I.S. 516 Using 12 Mm. To 20 Mm. Size Black Hard Crushed Broken Granite Stone Chips And Screened And Washed Sharp Sand For Mortar Of Approved Quality From Approved Quarry, Washed Andcleaned ( 20Mm. Size Chips Not To Exceeds 25 % ) To Be Mixed In Concrete Mixture With Portlandslag Cement ( Psc ) Including Hoisting, Lowering, Laying And Compaction Concrete By Using Vibrators, Watering And Curing For 28 Days, Centering And Shuttering Then After Dismantling And Removing Debris From The Work Site And Finishing The Exposed Surface Smooth Providing Grooves Or Beads Wherever Necessary Including Cost, Conveyance, Loading, Unloading, Royalties And Taxes Of All Materials And Cost Of All Labours, Sundries, T & P Required Of The Work Etc. Complete In All Respect As Directed By The Engineer-In-Charge. But Excluding Cost And Conveyance Of M.S. Rods Or Tor Steel And Binding Wires And Labour Charges For Straightening, Cutting, Bending Etc. Of M.S. Rods Or Tor Steel Tying The Grills And Placing In Proper Position. 757 Supplying, Straightening, Cutting, Bending, Placing In Position And Binding Reinforcement Steel Work In Rcc / Reinforced Brick Works As Per Drawing And Specification Including Preparation Of Respective Bar Bending Schedule Etc. All Complete As Per Direction Of Eic. 758 Cold Twisted Bars, Thermo-Mechanically-Treated Bars. 759 Providing And Constructing Brick Work Using Fly Ash Bricks In Cement Sand Mortar ( 1:4 ) In Foundations And Superstructures, Sewer, Drains Etc. Bonding, Lining, Levelling, Plumbing, Racking Out Joints, Curing As Per Specifications, All Materials, Tools And Labour Complete. 760 Boring / Drilling Bore Well Of Required Dia For Casing / Strainer Pipe By Suitable Method Prescribed In Is; 2800 ( Part-1 ) , Including Collecting Samples From Different Strata, Preparing And Submitting Strata Chart / Bore Log, Including Hire & Running Charges Of All Equipments, Tools, Plants & Machineries Required For The Job, All Complete As Per Direction Of Engineer-In-Charge, Up To 90 Metre Depth Below Ground Level. 761 A ) All Kinds Of Soil 300Mm Dia. 762 Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well Unplasticized Pvc Medium Well Screen ( Rms ) Pipes With Ribs, Conforming To Is : 12818, Including Hire & Labour Charges, Fittings & Accessories Etc. All Complete, For All Depth, As Per Direction Of Engineer-In-Charge. 763 200Mm Dia Pvc ( Sch-80 ) Pipe 764 Rainwater Pipe 110Mm Dia ( Type-A ) 765 160 Mm Dia Rain Water Pipe 766 Providing Fitting & Fixing Rcpc Cover Etc Complete As Per Direction Of Engineer -In-Charge. 767 Mh Cover 768 Ug Tank ( 50Kld ) 769 Earthwork In Excavation In All Types Of Soil For Site Leveling, Foundation, Pits, Trenches And Other Civil Works Up To And Including 1.5 Metre Lift And Stacking The Soil Upto A Lead Of 100 Metre And Including Dewatering, Removing Slush, Shoring And Strutting ( As Required ) , Complete As Per Specification And As Directed By The Engineer-In-Charge. 770 All Type Of Soil 771 Filling At All Depth With Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 15 Cm In Depth : Consolidating Each Deposited Layer By Ramming And Watering Complete ( Lead Upto 100M ) As Directed By The Engineer-In-Charge. 772 Excavated Earth Filling 773 Supplying Offilling Sand In Foundation And Over Areas Including Watering, Ramming, Consolidating And Dressing, Labours, Tools, Taxes Etc. All Complete As Per The Specification And Direction Of E.I.C. 774 Ug Tank 775 Providing And Laying Plain Cement Concrete 1:3:6 ( 1 Cement:3 Sand: 6 Stone Agregate 40Mm Nominal Size ) As Levelling Course In Foundation And Plinth Etc. Includingtempering, Curring, Shuttering Etc. Complete All Depth And Height. 776 Ug Tank 777 Providing, Lifting, Hoisting And Laying Reinforced Cement Concrete Of M-250 Grade As Per Approved Designs And Drawings Having A Minimum Compressive Strength ( In Work Test ) 250 Kg. / Square Cm. In 15 Cm. Cubes At 28 Days After Mixing And Test Conducted In Accordance With I.S. 516 Using 12 Mm. To 20 Mm. Size Black Hard Crushed Broken Granite Stone Chips And Screened And Washed Sharp Sand For Mortar Of Approved Quality From Approved Quarry, Washed Andcleaned ( 20Mm. Size Chips Not To Exceeds 25 % ) To Be Mixed In Concrete Mixture With Portlandslag Cement ( Psc ) Including Hoisting, Lowering, Laying And Compaction Concrete By Using Vibrators, Watering And Curing For 28 Days, Centering And Shuttering Then After Dismantling And Removing Debris From The Work Site And Finishing The Exposed Surface Smooth Providing Grooves Or Beads Wherever Necessary Including Cost, Conveyance, Loading, Unloading, Royalties And Taxes Of All Materials And Cost Of All Labours, Sundries, T & P Required Of The Work Etc. Complete In All Respect As Directed By The Engineer-In-Charge. But Excluding Cost And Conveyance Of M.S. Rods Or Tor Steel And Binding Wires And Labour Charges For Straightening, Cutting, Bending Etc. Of M.S. Rods Or Tor Steel Tying The Grills And Placing In Proper Position. 778 A ) Base 779 B ) Wall / Beam 780 C ) Slab 781 Supplying, Straightening, Cutting, Bending, Placing In Position And Binding Reinforcement Steel Work In Rcc / Reinforced Brick Works As Per Drawing And Specification Including Preparation Of Respective Bar Bending Schedule And Binding ( Binding Wire To Be Used As Per The Is Code ) Etc. All Complete As Per Direction Of Engineer-In-Charge.Cold Twisted Bars, Thermo-Mechanically-Treated Bars. 782 Steel 783 First Class Fly Ash Brick Masonry Usingf.A. Bricks Of Size 23Cm. X 12 Cm. X 8 Cm. Having Crushing Strength Not Less Than 75 Kg. Per. Sqr. Cm. In Cement Mortar Of Mix ( 1:6 ) With Ordinary Portland Slag Cement ( Psc ) And Screened & Washed Sand For Mortar After Immersing The Bricks For 6 ( Six ) Hours In Water Before Use In Foundation & Plinth Including Splays Cutting, Circular Moulding, Corbelling, Chamfering And Similar Such Type Of Works, Watering And Curing Etc. Including Cost, Conveyance, Loading, Unloading, Royalties And Taxes Of All Materials, Cost Of All Labour, Scaffolding, Sundries, T&P Required For The Works Etc. Complete In All Respect As Directed By The Engineer-In-Charge. 784 12Mm Cement Plaster On External Rcc / Brick Surfaces Incement Plaster 1:6 ( 1 Cement : 6 Coarse Sand ) Including Necessary Scaffolding, Curing Etc. All Complete At All Floors And All Heights. 785 16Mm Cement Plaster On Internal Smooth Side Of Rcc / Brick Surfaces With Cement Mortar Of Mix 1:6 ( 1 Cement : 6 Fine Sand ) Including Necessary Scaffolding, Curing Etc. All Complete At All Floors And All Heights. 786 6 Mm Cement Plaster On Internal Smooth Side Of Rcc / Brick Surfaces With Cement Mortar Of Mix 1:4 ( 1 Cement : 4Fine Sand ) Including Necessary Scaffolding, Curing Etc. All Complete At All Floors And All Heights. 787 Providing And Fixing Steel Work Welded In Built Up Section / Framed ( Including M.S. Angle, Plate, Sq.Bar, Flat, M.S.Tubular Section, Heavy Type Hinges ) Work Incuding Cutting, Hoisting, Fixing In Position And Applying Apriming Coat Of Approved Steel Primer, Two Or More Coats Of Synthetic Enamel Paint With Approved Make And Brand In Grating, Frames, Guard Bar, Ladder, Railings For Balconies And Straircase, Brackets, Gates And Similar Works As Per Direction Of Engineer-In-Charge. ( All Structural Steel ContractorS Own Supply ) . 788 Providing & Applying Priming Coat With Cementbase Primer Of Approved Brand And Manufacture Onplaster / Putty Surface As Per The Instruction Of Engineer-In-Charge At All Elevations And All Heights Including All Material & Labour Complete. 789 Providing And Applying To Outside Walls With Two Or More Coats Ofanti-Fungal Weather Coat Water Proofing Paint Including Scaffolding And Cleaning The Surface Before Application Of Approved Colour And Manufacture As Per Specification, Instruction Of Engineer-In-Charge At All Elevations Including All Material Labour Complete. In All Floors And All Heights. 790 Providing & Painting Two Coats Of Distempering Paint With 1St Quality Oil Bound Washable Distemper Of Approved Brand And Manufacturer To Give An Even Shade As Per The Instruction Of Engineer - In- Charge At All Elevations Including All Material & Labour Complete. 791 Providing & Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade As Per The Instruction Of Engineer - In-Charge At All Floors And All Heights Including All Material & Labour Complete. 792 Supplying All Materials, Labour, T&P And Providing Pidifin 2K Including Conveyance Of All Materials To Worksite, Payment Of Royalty, Taxes Etc All Complete As Per Specification And Direction Of The Engineer In Charge. 793 Supplying All Materials, Labour, T&P And Providing Cement Punning Including Watering, Curring And Conveyance Of All Materials To Site. 794 Supplying And Fitting And Fixing Stainless Steel 34 Grade In Said Rail Using 5Mm Dia 2Mm Thick Circular Pipe And Balustrade 32Mm X 32Mm X 2Mm Below Including Welding Welding With Stainless Steel Elect Rod And Fixing With Necessary Accessories Ete. Complete As Per Direction Of The Engineer-In-Charge. 795 Providing Fitting & Fixing Rcpc Cover Etc Complete As Per Direction Of Engineer -In-Charge. 796 Mh Cover

Key Value

Document Fees
INR 10000 /-
EMD
INR 1126000.0 /-
Tender Value
INR 11.25 Crore /-

BOQ Items

Name of Work: Construction of Administrative Building of Drugs Control Administration, Bhubaneswar.
Sl. No. Item Description
1CIVIL WORK Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenchesand other civil works upto and including 1.5metre depth and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge.
2Stilt Floor
3All kinds of soil
4Disintegrated rock
5Road
6Drain
7Parking
8Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth:consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge.
9Stilt Floor
10Road
11Drain
12Parking
13Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge
14Stilt Floor
15Drain
16Parking
17Disposal of surplus excavated materials by mechanical means from the work side etc. complete. upto 5km. Leadincluding cost of all labour T&P required for the work etc. complete as directed by Engineer-In-Charge.
18Stilt Floor
19Supplying, diluting & preparing chemical emulsion like imidaclosed 30.5% SC or other chemicals approved by central insecticides Board or as directed by manufacture and spraying the mixture uniformly by sprayer as Pre-Constructional Anti Termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall treanches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding of pipes and conduits etc. at the rate of 7.5liters per sqm on vertical surface and 5.0liters per sqm on horizontal surface, 50% of the emulsion to be filled in the holes made in treanches at 150mm centre to centre (or as directed directed by the manufacture) including the cost of all material, cost of all labour, conveyance, loading, unloading, T&P, etc all complete as per the direction of Engineer-in-charge. ( Approved rate for MPH building Sl no-1)
20Stilt Floor
21Cement concrete of proportion (1:4:8) in foundation and floors using 4cm size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6") thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect and as per the direction of the Engineer-in-charge.
22Stilt Floor
23Drain
24Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge.
25Stilt Floor
26Road
27Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties of all materials with labour,labour cess and T&P etc. required for the work complete as per the direction of the Engineer-in-charge.
28Stilt Floor
29Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.
30Stilt Floor
31Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.
32Stilt Floor
33First Floor
34Second Floor
35Third Floor
36Terrace Floor
37Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.
38Stilt Floor
39First Floor
40Second Floor
41Third Floor
42Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed andcleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portlandslag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.
43Foundation
44Stilt Floor
45Drain
46Plinth beam
47Stilt Floor
48Column up to PL
49Stilt Floor
50COLUMN IN SUPERSTRUCTURE
51Stilt Floor
52First Floor
53Second Floor
54Third Floor
55Terrace Floor
56Drain
57LINTEL
58Stilt Floor
59First Floor
60Second Floor
61Third Floor
62Terrace Floor
63ROOF BEAM
64Stilt Floor
65First Floor
66Second Floor
67Third Floor
68Terrace Floor
69ROOF SLAB
70Stilt Floor
71First Floor
72Second Floor
73Third Floor
74Terrace Floor
75Drain
76STAIRCASE
77Stilt Floor
78First Floor
79Second Floor
80Third Floor
81CHAJJA
82Stilt Floor
83First Floor
84Second Floor
85Third Floor
86Terrace Floor
87R.C.C. work of M-20 in following works using 12 mm. to 20 mm. (½” to ¾”) size (20 mm. not to exceed 25%) hard black crusher broken granite stone chips of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,labour cess and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position and as per the direction of the Engineer-in-charge.
88Road
89Parking
90Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. includingbending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.
91Stilt Floor
92First Floor
93Second Floor
94Third Floor
95Terrace Floor
96Road
97Drain
98Parking
99Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
100Stilt Floor
101First Floor
102Second Floor
103Third Floor
104Terrace Floor
105Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
106Stilt Floor
107First Floor
108Second Floor
109Third Floor
110Terrace Floor
111Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
112Stilt Floor
113First Floor
114Second Floor
115Third Floor
116Terrace Floor
117Supplying, fitting and fixing vetrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm plain (Ivory)of approved make(Johnson/ Somany/ Kajaria/ OASIS/ RAK) as directed by Engineer-in-charge in floors on 20mm thick bed of C.M. (1:4) (1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tileincluding cost of all materials, labour, labour cess, T&P etc. required for the work completein all respect as directed by the Engineer in charge.
118Stilt Floor
119First Floor
120Second Floor
121Third Floor
122Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm plain (Ivory)of approved make (Johnson/ Somany/ Kajaria/ OASIS/ RAK) as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects as directed by the Engineer in charge.
123Stilt Floor
124First Floor
125Second Floor
126Third Floor
127Fixing granite tiles of approved dimension area above 0.4 sqm (20mm thick) in floor, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials complete in all respects as per direction of Engineer-in-Charge.
128Stilt Floor
129First Floor
130Second Floor
131Third Floor
132Fixing of Kota stone tiles of minium thickness 16mm thick of premium grade of size above 0.10 Sqm. in floors over 20mm thick bed of cement mortar 1:4 (1cement:4course sand)and filling the joint with white cement mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance,royalties of all materials, labour,labour cess with T&P complete in all respects as per direction of Engineer-in-Charge.
133Stilt Floor
134First Floor
135Second Floor
136Third Floor
137Supplying, fitting and fixing vetrified Industrial tiles in floors of premium grade having thickness 8mm to 10mmof size 300mm x 300mm confirming to IS 4457 with colour / printed series of approved make (Johnson/ Somany/ Kajaria/ OASIS/ RAK) as directed by Engineer-in-charge on 20mm thick bed of C.M. (1:4) including cost of all materials, labour, T&P etc. required for the work in all respect as directed by the Engineer in charge.
138Stilt Floor
139Wooden flooring :- Supply &instaliation of BADMINTON WORLD FEDERATION (BWF) approved Wooden Sports flooring system "AIRFLEX SMASH" that should be compiiance with the Area elastic with total thickness of 75 mm comprising of 20mm Top Solid Wood followed by 45mm solid wood runner and 10mm Power Rubber Pad Product top finish to have square Edge & UV Prefinished with Back Side Coating (Polished used of Klumpps frorn Germany which is sweat and saliva resistance according to DIN 53160 1/2) to have higher polish lite. The wooden flooring should have Eco-friendly manutacturing process wih 100% sustainable and manageable plantation resource with raw mateiai The product should have been produced through Kilned and dried technology to maintain suitable moisture content The top wood shouid necessarily be sourced from 100% sustainable resource and should have with prefinished including sanding & polishing. Structure of system should be 10mm thick rubber pad, 45mm thick pine runner with the width of 70mr, followed by the 20mm top flooring Top wood plank sizes should be 20rnm Thick, 130mm Wide and 1830mm length. Runners to be placed at a distance of 305mm C/C Entire system should follow norms with the EN 14904(06/2006) and technical parameters for the praduct should have friction of 95 according to EN 13036-4, Shock absorption of 45% according to EN 14808, Vertical deformation should be 1.8mm according to EN 14809 and Vertical ball rebound should be 99% according to EN 12235. ( Approved rate for MPH building Sl no-12)
140Third Floor
141Supplying and fitting -fixing of un-plasticised poly vinyl chloride (UPVC) (FENESTA / NCL VEKA LTD/ Prominence/ Koemmerling or equivalent make of similar specification) Threetrack-three panel sliding window-60-series duly manufactured using UPVC reinforced profiles of 108mmx45mmx2.5mm for outer frames & window sash of 39mmx58mmx2.5mm capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window frame shall be fitted with 6mm thick clear tougherned glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant and the system is to be installed using reinforced large coupler at the site using anchor fasteners, sliicon rubber sealant, easy glazing/ deglazing at site etc. including cost and conveyance of all materials, accessories, labour charges,materials and product conforming to ASTM D 638-14,EN-477-95 and other applicable codes & standards.( Rate Approved from Nirman soudha Ltr no- 20894,Date-26.05.2022)
142Stilt Floor
143First Floor
144Second Floor
145Third Floor
146Terrace Floor
147Providing and fixing of 12mm thick clear toughened Glass frameless door with dorma premium fittings Dorma premium (9111198) unilite package BTS 75,UL PT 10 with cover,UL US 10Luck with cover and PT 24,Dorma premium(9137121) H Type handle 450mm, 12mm clear toughened glass with cutout and hole, including the cost of all materials hardware fittings ,cost of all labour, conveyance,l oading, unloading, T&P,etc complete as per the direction of engineer-in-charge. ( Approved rate for MPH building Sl no-18)
148Stilt Floor
149First Floor
150Second Floor
151Third Floor
152Dressed seasoned sal woodworkframed andfixedinframesofdoors&windows including cost,conveyanceofall materials and cost of labour for fitting, fixing etc.complete as per the instruction of Engineer-in-Charge.
153Stilt Floor
154First Floor
155Second Floor
156Third Floor
157Providing and fixing 30mm thick flush door shutters conforming to IS:2002 (Part I) decorative type , core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both face of shutters inclusive of 4 nos of stainless steel Butt hinges (100 mm x60 mm x2.5mm ) 40mm stainless steel screws. Cylindrical Lock (Godrej-9843), Tower bolt SS 10 x 300 mm (Bathroom) Godrej 3264,PVC Door buffer with SS screw , teak wood lipping around the edges & paste with 1.5 mm thick laminate on both side of the flush door , etc. including the cost of all materials, hardware fittings, cost of all labour, conveyance, loading, unloading, T&P, etc, complete as per the direction of engineer-in-charge. ( Approved rate for MPH building Sl no-15)
158Stilt Floor
159First Floor
160Second Floor
161Third Floor
162Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and designwith cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge.
163Stilt Floor
164First Floor
165Second Floor
166Third Floor
167Terrace Floor
168Drain
169Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge. (Make: Asian/ ICI/ Berger or equivalent make duly approved by Engineer-in-Charge)
170Stilt Floor
171First Floor
172Second Floor
173Third Floor
174Terrace Floor
175Painting two coats with approved antifungal weather seal paints (ISI) of approved colour, shade on wall surface over a coat of wall primer(ISI) water bound including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour,labour cess with T&P etc, complete as per specification & direction of Engineer-in-charge. (Make: Asian/ ICI/ Berger or equivalent make duly approved by Engineer-in-Charge)
176Stilt Floor
177First Floor
178Second Floor
179Third Floor
180Terrace Floor
181Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. (make: JK white/ Birla white or equivalent make duly approved by Engineer-in-Charge)
182Stilt Floor
183First Floor
184Second Floor
185Third Floor
186Terrace Floor
187Painting two coats with plastic emulsion paint over a coat of water bond cement primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge. (Make: Asian/ ICI/ Berger or equivalent make duly approved by Engineer-in-Charge)
188Stilt Floor
189First Floor
190Second Floor
191Third Floor
192Terrace Floor
193Painting two coat with approved synthetic enamel paint to new wood over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. (Make-Asian/ Berger/ ICI or equivalent make duly approved by Engineer-in-Charge).
194Stilt Floor
195First Floor
196Second Floor
197Third Floor
198Terrace Floor
199Road
200Parking
201Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance of all materials, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge.
202Stilt Floor
203First Floor
204Second Floor
205Third Floor
206Terrace Floor
207Expansion joint Treatment Supplying and fixing of Elastomeric Membrane of 200mm x 2mm size for expansion joint sealing from approved manufacturer, fixing with epoxy adhesive of approved quality complete.
208Stilt Floor
209Finishing walls with textured exterior paint of required shade approved make and finishing the surface to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, all materials, cost of all labour, labourcess, all T&P etc required for the work complete in all respect as per direction of the Engineer-in-charge: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm (Make: Asian/ Berger/ ICI or equivalent make duly approved by Engineer-in-charge)
210Building Proper
211Structural Glazing. Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474 including super durable powder coating of 60 80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). ( Approved rate for MPH building Sl no-30)
212Building Proper
213Structural Glazing :- Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 675 part N (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc gaskets, screws, toggles, nuts, bolts, clamps etc, structural and weather silicone sealants flashings, fre stop (bamer)-cum-smoke seals, microwave cured EPDM gaskets for water lightness, pressure equalisation & drainage and protection against fire hazard including (b) Fabricating and supplying serrated M.S. hot dip galvanised Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing systern rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a dean and controlled factory/work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for noiding glass (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.( Approved rate for MPH building Sl no-31)
214Building Proper
215Providing and fixing of Canopy with WPC(Wood Plastic Composite) Wall Cladding Plank with density 18.84 Kg/m2 as per ASTM D2395.2007A D 792:2000 Water absorption after 2 hours 0.33% as per ASTM D1037:2006a section 23 Method A/D570:1998, linear thermal expansion coefficient 62.5 um/m degree celcius as per ASTM D696-2008 with all aluminium frame work and accessories for fitting the WPC sheets onto the structural system. The item shall be inclusive of the fittings and fabrication costs and the accessories required to do so. It should be resistant to steam and crack, with all necessary fittings including cost of all materials, labour, conveyance, loading unloading, tools and plant,sundries etc all complete as per techinical specification and direction of Engineer in Charge.( Approved rate for MPH building Sl no-29)
216Building Proper
217SUN LOUVERS:- HI-STEEL Aluminum Sun Louvers 84R system comprises of 84 mm wide and 16 mm deep roll formed out of aluminum coils. In Aluminum, Panels are made of 0.5mm thick aluminum alloy 3105/3005 and Carriers are made of 0.9mm thick aluminum alloy with cut-outs to hold panels. Aluminum panel and carrier shall be polyester powder coated with 60-70 microns. HI-STEEL Sun louver system is a vertical or horizontal wall sun shading system. The system use 84 R panels that snap into vertically mounted frames. The frames can be mounted on the exterior of a building over window openings, along balconies or over open area on a building elevation. The vertical/horizontal frames are offered in two different designs that hold the panels at different angles of 35 and 45 degrees. The ranges of angles provide air flow, sun shading, safety from rainfall and desired visibility.
218Building Proper
219Gyp Board Ceilling :- Providing and fixing False ceiling as per Anutone / Saint Gobain or equivalent make duly approved by Engineer-in-charge Specifications made of standard G.I. Sections and 12mm thick gyp board sheets inclusive of all hangers, edge members and other clips complete, with sheets fixed with proper Philip fastner by power drills and joints duly finished ensuring level in line, complete with putty, primer and painting of approved make and colour. Cost includes cutouts for electrical fittings, materials, labour, T&P etc complete as per direction of the Engineer-in-charge. (Basic Rate of Gypsum Board 12mm thk. Rs.303/ sheet).
220First Floor
221Second Floor
222Third Floor
223GRID CEILING WITH ANUTONESUBTEX NUBBY STEP EDGE :- Supply and Installation of Anutone 15 mm glassfiber steppe edge Glass fibre core ceiling tile of size 595 x 595 x 15mm having all edges encapsulated with chemical treated paint & having density 100-120 Kgs/ m3, weight 1.5 - 3.0 kg/m2 which is suspended by using 0.3mm thick and 15 mm wide pre coated metal T15/24 grid system. The technical parameters are as follows :Core - Glassfibre, Fire – Class 1 & P , Acoustics – NRC 0.95,Climate (OC RH) – 40, 95,Termite resistance ,Light reflectance – 85 %,Green (RC %) – 35, Hygiene (VoC, Clean room) – Low, Class 3 Strength, Load capacity (Kg) - Antisag. The T15/24Grid system of 600 x 600 mm module shall include wall angle(WA15) with unequal flanges of size 14 x 20 x3000mm wide, length 3000mm, 0.43 mm thick fixed along the perimeter of wall with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the Main T15(MT15W36) having flange width 15mm /24 mm , height32/38 mm and length 3600mm thickness 0.30 mm from the soffit with help of soffit cleat and wire at 1200mm c/c. Cross T15 (CT15W12) with flange width 15 mm, height 32 mm and length 1200 mm is then interlocked into the pre-cut slots in the Main T15 at 600mm centers in the direction perpendicular to the Main T15. Finally Cross T15 (CT15W06) having flange width 15 mm, height 32mm and length 600mm are then interlocked into the pre cut slots in the 1200 mm Cross T15 at 1200mm centers andin direction parallel to the Main T15.Anuton Subtex Nubby steppeedge of size 595 x 595 x 15mm thick shall be placed into the grid size of 600 x 600 mm. Ensure arrow marks behind subtex panels are orianted in one direction to achieve uniform shade.Test certificate will be submmited after procurement of materials.
224First Floor
225Second Floor
226Third Floor
227GRID CEILING MAGNESIUM OXIDE VINYL FLIM SQUARE TILES:- Supply and Installation of 8 mm thick magnesium oxide square edge magnesia core ceiling tile of size 595 x 595 mm having density 1000 Kgs/ m3, weight 8 kg/m2 which is suspended by using 0.3 mm thick and 24 mm wide precoated metal T 24 grid system. The technical parameters are as follows :Core - Magnesia, Fire – Class 1 & P, Acoustics – STC 44 - 54 , climate - 50 , RH - 95,Termite resistance ,Green (RC %) – 30, Hygiene (VoC, Clean room) – Low, Class 3 , Thermal-0.12 W/mK. The T 24 Grid system of 600 x 600 mm module shall include wall angle (WA 24 W 30) with unequal flanges of size 14 & 20 mm wide, length 3000 mm, 0.43 mm thick fixed along the perimeter of wall with the help of nylon sleeves and suitable fasteners at 300 mm centers. Then suspend the Main T 24(MT 24 W 36) having flange width 24 mm, height32 mm and length 3600 mm from the soffit with help of soffit cleat and wire rod along with leveling spring clip at 1200 mm c/c. Cross 24(CT 24 W 12) with flange width 24 mm, height 32 mm and length 1200 mm is then interlocked into the precut slots in the Main T 24 at 600 mm centers in the direction perpendicular to the Main T 24. Finally Cross T 24 (CT 24 W 06) having flange width 24 mm, height 32 mm and length 600 mm are then interlocked into the precut slots in the 1200 mm Cross T 24 at 1200 mm centers andin direction parallel to the Main T 24. Magnesium oxide vinyl square edge of size 595 x 595 x 8 mm thick shall be placed into the grid size of 600 x 600 mm.Test certificate will be submitted after procurement of materials.
228First Floor
229Second Floor
230Third Floor
231PANELLING - WALL PANELING WITH WOODEN SALON SALTS SURCO :- Anutone or equivalet. Supply & installation ofwall paneling of Anutone slats surco high density fiberboard made out ofpure pinewood particles, Fire Resistance- Pink in colour core with5 test Fire Resistance BS 476 part 5 , BS 476 part 6 , BS 476 part 7 ISO 1182 ASTM E662 Smoke Density- Melamine laminated finish, perforated wooden grooved HDF slatsL16-2 (2 mm grooves @ 8 mm centers),tongue-groove edge for a seamless look of lineal dimension size 128 mm x 2440 mm x 16 mm thick having density 700 Kg /m3, weight -9 Kgs/m2 with back fleecs from soundtex Germany nonwoven acoustic to be pasted on slats surco is to be installed by using GI strut system. The technical parameters are as follows Core Variants - Fiberboard, Climate (OC RH) – 50, 70 Light reflectance – 75%,Green (RC %) – 25, Hygiene (VoC, Clean room) – Low, Class 1,Strength, Load capacity (Kg) - Anti sag, Ball-Impact.The concealed wall paneling system shall include GI Wall channel (WC25) having thickness 0.45mm, length 3600mm, unequal flanges of 15 & 20mm and web of 25mm should be fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Then fixed Main channels (MC45) having thickness 0.9mm, length 3600mm, equal flanges of 15mm and web 45mm from the side wall & fixed at every 1200mm centers with GI cross channel(CC25) having thickness 0.45mm, length 3600mm, knurled web 35mm, depth of 25mm and equal flanges 9.5mm is fastened to the Main channel in the direction perpendicular to the Main Channel at every 600mm centers. The framework will maintain 50 / 75 mm gap from the walls. Now clad the wooden slats surco on the CC 18 with the help of center & edge clips to get better locking of slats. The tongue & groove are to be properly aligned to get flush look . Synth poly fiber PF 5 x 50 wool of 500 gsm to be filled between the horizontal & vertical studs as in filler with the help of wire / stick 7 adhesive. Test certificate of the use products shall be submitted after procurement of materials
232Third Floor
233PANELLING - WALL PANELING STRETCH FABRIC NRC/HUSH :- Anutone or equivalet. Supply and installation of Anutone Stretchable acoustical fabric NRC fabric system by using FR Grade NRC fabric of size 1700 mm width, shall be stretched by using wooden base 10 mm thick rigid vinyl stretch tracks half wrap/ full wrap 15 mm FS15 & mid seam 15 mm FS 15, 15 mm pinewood magnesia bonded Strand board, Synthetic poly fiber 5x50 infill with requisite accessories & tools. Pinewood wood based wool fiber having 15 mm thick square edge is first installed on the wall along the marking lines with metal fasteners inserted at 300 mm centers FS 15 tracks to be installed on wooden base after applying stick S7 adhesive on both surfaces for a true & continuous secure grip, & heavy - duty fasteners at 150 mm centers on both sides of stretch tracks. Pinewood wool panels having square edge Magnesite bonded pinewood fibers panels of size600 x 1200 x15 mm having density 400 Kg /m3 , weight 4 kg which is fixed to GI Channel CC25 on walls placed at 600 mm centersvertically / Horizontally with suitable fasteners with MC 45 at 1200 c/c & WC 25 is for supporting the main frame.. Synthetic poly fiber Anutone PF 5 x 50 mm thick adhered on strand tracks by following the fabric thread line or pattern. The fabric NRC is stretched & tucked into the stretch tracks & secure into the locking jaws so that it will be smooth, free of wrinkles with the tucking tools. Note - minimum 50 mm additional fabric is required for tucking hence maximum module wall fabric width would be 1600 mm The technical parameters of the system are core - pinewood fibre & polyfiber Fire - 1 Acoustic - NRC 0.85 Climate OCRH - 49, 90 Termite resistance - yes , light reflectance - colour dependant , Green RC % - 25 , Hygiene( Voc , Clean room ) - Low , Class 1. Test certificate will be submitted after procurement of materials.
234Third Floor
235WOODEN PANELLING WITH VEENER :- Providing, fitting and fixing full height wooden paneling to walls and columns wher ever necessary from floor lvl to ceiling ht or as per drawing/design made out of 50.8mmx25.4mmx1.34mm thick Aluminium rectangular sections placed@ 600mm c/c both ways on grid, on top of grid 12mm fire resistant and termite proofply (conforming to IS code :5509)to be provided with 4mm thk veneer of approved shade and colour finished with melamine polish as per design/drawing or as directed by the Architect/Engineer-in- Charge. The rate includes cost of cutouts for electrical switches, light fixtures, wall bracket fans if any, all complete with materials, labour, T&P, taxes etc. (Basic Rate of 12mm thk.Sylvan ply, Marine ply Rs.968.4/Sqm & 4 mm thk. veneer Rs.2500/Sqm).
236Third Floor
237Providing and laying grading conc. 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer"s specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor.
238Terrace Floor
239Waterproofing Treatment :- Terrcae Roof Top Surface :- Providing and installing two component acrylic modified cementitious waterproofing coating with masterseal 551/Equivalent over roof slab after carrying out pond test on roof slab filling all defects, saturating the surface mixing the products and then application in 2 mm thickness MYK POWER PRUFE 800/ SIKA/ FOSROC or equivalent make duly approved by Engineer-in-charge (1.8kg/sqm coverage rate for 1mm thickness ) in suitable layers complete in all respect, all materials, tools,plant & labour complete in all respect.( Approved rate for MPH building Sl no-05)
240Terrace Floor
241Dismantling brick or stone masonry in lime or cement mortar above 3m height including stacking the useful materials for re-use and removing the debris with in 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.
242Stilt Floor
243Dismantling and removing R.C.C. columns beams slab staircase landing lintels including stacking the useful materials for reuse and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.
244Stilt Floor
245Construction of granular sub-base by providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MOSRT&H Specifications for Road & Bridge works (4th Revision)
246Road
247Parking
248Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam (WMM) specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density as per Clause 404 of MoSRT&H Specifications for Road & Bridge works (4th Revision)
249Road
250Parking
251Treatment of Expansion Joint on Concrete Road 10mm(W) x 20mm (D):- At the time of concreting thermo cool of 15mm should be placed to bifurcate & maintained groove size of minimum 10mm in width. After maturity of concrete with water curing, Surface Treatment of groove will be done manually to make it sure of groove size 10mm x 20mm. Air Blower to be used to clean dust particle. Providing & Appling 10mm backer rod must be fixed to fill up the bottom of the expansion joint as per depth required. Masking tape should be fixed both the surface area to protect the spillage of materials. Providing & Appling Nerolac-Perma Polyseal PG (Grey Sealant) highly elastic, UV Resistance, High degree temperature resistance upto 100 Degree Centigrade to be filled with caution that no air pocket should be form.
252Road
253Supplying and fixing of 60mm thick cement concrete interlocking paver block of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP-63:2018.
254Parking
255E.I. WORK INTERNAL WIRING. Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit Make-NORPACK/Havells or equievalant reputed make with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge.Make- Finolex//HAVELLS/RR CABLE/polycaborequivalent make duly approved by Engineer-in-charge) (Make of modular box,cover,switch & socket-Legrand Myrios/schneider opale/Eq) With 10Years Warenty.
256Group C
257Recessed wiring to secondary light pointlooped from primary light point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduitMake-NORPACK/Havells or equievalant reputed make with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer-in-charge. Make- Finolex//HAVELLS/RR CABLE/polycaborequivalent make duly approved by Engineer-in-charge)Average Length: 3mtr.
258Recessed wiring to ceiling fan point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduit Make-NORPACK/Havells or equievalant reputed make with 6 Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. Make- Finolex//HAVELLS/RR CABLE/polycaborequivalent make duly approved by Engineer-in-charge)Group B
259Recessed wiring to Twin control light pointwith 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduitMake-NORPACK/Havells or equievalant reputed make with 6Amp, 250 V clip in type 2way switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer-in-charge. (Make- Finolex/HAVELLS/RR CABLE/polycaborequivalent make duly approved by Engineer-in-charge)Group C
260Recessed wiringfor 5 / 6 amp socket outletwith6Amp, 250 V clip in type modular switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on same switch board as per direction of Engineer-in-charge.
261Recessed wiringfor 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit Make-NORPACK/Havells or equievalant reputed make with 6 Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable size ,with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer-in-charge. Make- Finolex/HAVELLS/RR CABLE/polycaborequivalent make duly approved by Engineer-in-charge)Group C
262Recessed wiringfor2 x 6 amp socket outlet controlled by 2 nos6Amp, 250 V clip in type switch ISI markedmounted on single G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on separate board as per direction of Engineer-in-charge.
263Recessed wiringfor 6 pin 16 amp socket outletwith 16Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection as per direction of Engineer-in-charge. 25Nos for Stage Light,3Nos For Aquaguard.
264Recessed wiringfor A.C/ Power socket outletwithindustrial type socket outlet,plug top and metal chained cover in sheet steel enclosure,20A/32A SP MCBincluding all accesories and connection as per direction of Engineer-in-charge.
265Recessed wiring to exhaust fan/Wall Fan point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduit with 6Amp 250V Modular Switch, Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Orient / Eq)Group B
266Call bell point
267Recessed wiringfor3 x 6 amp socket outlet controlled by 2 nos6Amp, 250 V clip in type switch ISI markedmounted on single G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on separate board as per direction of Engineer-in-charge.
268SUBMAIN.
269Recessed wiring to submain in 4 x 16 sq.mmFRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 50 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick Make-NORPACK/Havells or equievalant reputed make along with 2 x 10 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make- Finolex/HAVELLS/RR CABLE/polycaborequivalent make duly approved by Engineer-in-charge)
270Recessed wiring to submain in 4 x 10 sq.mmFRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 40 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick Make-NORPACK/Havells or equievalant reputed make along with 2 x 6 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired.(Make- Finolex/HAVELLS/RR CABLE/polycaborequivalent make duly approved by Engineer-in-charge).
271Recessed wiring to submain in 2 x 6 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick Make-NORPACK/Havells or equievalant reputed make along with 1 x 4 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make- Finolex/HAVELLS/RR CABLE/polycaborequivalent make duly approved by Engineer-in-charge)
272Recessed wiring to submain in 2 x 4 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick Make-NORPACK/Havells or equievalant reputed make along with 1 x 2.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make- Finolex/HAVELLS/RR CABLE/polycaborequivalent make duly approved by Engineer-in-charge)
273Recessed wiring to submain in 2 x 2.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick Make-NORPACK/Havells or equievalant reputed make along with 1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make- Finolex/HAVELLS/RR CABLE/polycaborequivalent make duly approved by Engineer-in-charge)
274Recessed wiring to submain in 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick Make-NORPACK/Havells or equievalant reputed make along with 1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. Make- Finolex/HAVELLS/RR CABLE/polycaborequivalent make duly approved by Engineer-in-charge) (For Switch Board Looping)
275DB. Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required wih necessary MCB , RCCB / ISOLATORS as required.Note for MCB- There should be colour indication for tripping On ,Off & Trip/There should be mid tripposition for toggles for electrical fault conditions.(With 5Years Warenty)
276Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted12 way SPN Distribution Boards For LDB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-40ADPMCB (10KA)Outgoings-10A SP MCB 10KA-10Nos.(Make-L&T/ Schneider/Legrand/Eq)
277Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted4 way TPN Distribution Boards For PDB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-63AFPMCB (10KA)Outgoings-10/20A SP MCB 10KA-12Nos.(Make-L&T/ Schneider/Legrand/Eq)
278Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted4 way TPN Distribution Boards For FLDB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-63AFPMCB (10KA)Outgoings-40A DP MCB 10KA-6Nos.(Make-L&T/ Schneider/Legrand/Eq)
279Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted4 way VTPN Distribution Boards For FPDB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-100AFPMCCB (25KA)Outgoings-63A TP MCB 10KA-4Nos.(Make-L&T/ Schneider/Legrand/Eq)
280CABLE .
281Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of3.5core 240 sq.mm direct in groundincluding excavation , sand cushining protective covering and refilling the trench etc. as required.(Make-polycab/RR Kable/Rhino cable/Eq)
282Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of3.5core 150 sq.mm direct in groundincluding excavation , sand cushining protective covering and refilling the trench etc. as required.(Make-polycab/RR Kable/Rhino cable/Eq)
283Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of 3.5core 50 sq.mm direct in groundincluding excavation , sand cushining protective covering and refilling the trench etc. as required.(Make-polycab/RR Kable/Rhino cable/Eq)
284Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of 3.5core 35 sq.mm direct in groundincluding excavation , sand cushining protective covering and refilling the trench etc. as required.(Make-polycab/RR Kable/Rhino cable/Eq)
285Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of4 core 16 sq.mm Aluminium on surface as required.(Make-polycab/RR Kable/Rhino cable/Eq)
286END TERMINATION
287Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.
2883.5C x 240 sq.mm
2893.5C x 150 sq.mm
2903.5C x 50 sq.mm
2913.5C x 35 sq.mm
2924C x 16 sq.mm
293PANEL
294Supply, installation,testing & commissioning of floor mounting front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55 protection with hinged and lockabale doors.CRCA sheets including interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 KA symmetrical for 1 sec at 415 V complete as per specifications, as required and as below : All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used with Indication lamp,C.T , Digital Voltmeter,Digital Ammeter and control fuse etc. complete.MAKE- Legrand / Schneider/ L&T/SIEMENS/Eq.
295MAINPANEL with 400A 4P MCCB 50KA -1 No as incomer, 200A 4P MCCB 36KA 2 Nos,100A 4P MCCB 25KA 6 Nos. 250A 4P Change Over Switch 1Nos, & 63A 4P MCB 10KA 10Nos. with E.C Busbars with 4nos 65KA VSD along with 4nos 32A SP MCB.
296EXT Light DB with 63A 4P MCB (10KA) -1 No as incomer, 1Nos Timer Switch ,20A SP MCB 10KA-12 Nos, 20A DP MCB 10KA 6Nos. as Outgoing with E.C Busbars .
297PUMP Panel Boardwith 63A 4P MCB (10KA) as Incomer , Outgoings-32A 4P MAB 10KA-2Nos, 20 A DP MCB 10KA-3Nos,withE.C Busbars.
298LIFT DB with 63A 4P MCB (10KA) -1 No as incomer ,40A 4P RCCB 100MA -1Nos, 10A SP MCB 10KA-6 Nos as Outgoing with E.C Busbars .
299EARTHING
300Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required.
301Supplying and laying 25 mm x 6 mm CU earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required.
302Supplying and laying 25 mm x 6 mm CU earth strip ISI marked on surface or in recess for connection etc as required.
303Providing and fixing 8 SWG CU wire on surface or in recess for loop earthing as required.
304FIXTURE
305Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required. (Make: Lighting Technology/Philips/Orient/ Jaquar reputed make orequivalent make duly approved by Engineer-in-charge). With 5Years Warenty.
306Ceiling mounted indoortype 24W batten typeLED Light.
307Ceiling/ Wall mounted type 10W BULK HEADLuminaire Light
308Supply, Installation, testing and commissioning of 10W Mirror Light
309Supply, Installation, Testing and Commissioning of ceiling fan 1200mm sweep, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required.
310Supply, Installation, testing and commissioning of exhaust fan of 300 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etcas required.
311Supply &fixing of 12W LED Down Light (S) .
312Supply &fixing of LED 36w 2"x2" Surface Mounted Light.
313Supply, Installation, testing and commissioning of 6W Ceiling mounted indoortypeRound RecessedLEDLight.
314Supply &fixing of 5W LED Wall Decorative LIGHT accessories.
315Supply, Installation, testing and commissioning of wall fan of 400 mm sweepas required.
316Perforated type cable tray
317Supply and installation of Pregalvanised Perforated type cable trays without cover. The rate shall include bends, Tees, all supporting brackets, anchor fasteners, screws, bolts, nuts etc., including painting of cable trays. Thickness of sheet steel shall be 2 mm. Support sizes similar to ladder type trays
318Size of Cable Tray :300 mm x 50 mm
319Size of Cable Tray :150 mm x 50 mm
320TV /TEL & DATA
321Supplying and fixing ofclip in type modular Telephone socket ISI markedmounted on G.I modular box with face plate & cover of suitable size ,including all accesories and connection as per direction of Engineer in Charge.
322Supplying and fixingof clip in type modular T.V. antenna socket ISI marked onmounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge.
323Supplying and drawing 4 pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessedPVC conduit as required.
324Recessed wiring to television point withcable RG-6 grade, 0.7 mm solid copper conductor PE insulated shielded with fine tined copper braid and protected with FR PVC sheath in in existing surface / recessedPVC conduit as required as per direction of Engineer in Charge.
325Supplying and fixing of following sizes PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required.
32620mm
327Supplying and fixing of 16 / 18 SWG metal box of 200 mm x 150 mm x 60 mm deepon surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required. ( Tel junction Box)
328Supplying & Commissioning of Telephone Hand Set.
329Supplying & installationof 50 pair KRONE make moudles with locking & key arrangements fabricated with MS sheet & powder coated to be fixed on concealed manner incl. good the damages.
330Supplying & installationofMatrix EPABX System For 200 extension line and 2 trunk line as required.
331SAFETY EQUIPMENTS
332Supply and installation of Rubber Mats 12mm thick of size 2000mm x 1000mm x 12 mm thick Electrical tested with test certificate.
333Supply and fixing of fire buckets with angular fabricated stand to fix 4 buckets in each stand for Electrical fire protection as per standards of Electrical Inspectorate.
334Supply and fixing of Co2 fire extinguisher with mounting clamps with pressure test certificate .
335Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room.
336Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room.
337150-KVA Silent D.G. SET
338Supply & delivery of 150-KVA silent DG sets along with engine-alternator, Control panel containing 1 No 200-A, 4P MCCB & required protections and metering arrangement (in tamper proof compartment with locking arrangement) With AMF Panel type with 5-A digital KWH meter & CTs for DG set, etc as required , acoustic enclosure, diesel tank, residential silencer and complete as required as per the technical specification and as per direction of Engineer-in-charge.
339Installation, testing andcommissioning of 150-KVA silent DG sets along with engine-alternator, Control panel containing 1 No 200-A, 4P MCCB & required protections and metering arrangement (in tamper proof compartment with locking arrangement) with 5-A digital KWH meter & CTs for DG set, etc as required , acoustic enclosure, diesel tank, residential silencer and complete as required as per the technical specification and as per direction of Engineer-in-charge.
340DG Set Foundation including barbared wire fencing / Roof shade as required.
341TP Meter Box of150 KVA DG set
3421 No 3 phase 4 wire 5amp CT operateddigital KWH meter in tamper proof enclosure with locking and sealing arrangement along with suitable bus bar arrangement,for mounting of C.T"s & 200/5-A CTs, cable termination arrangement complete as required
343Lightning Arrester.
344Supply & fixing of lightning arrester of size 2.6" length made of 0.5"diameter copper rod, over which 5nos 5" length pointed copper rods of 0.3" diameter with suitable size of nuts and bolts.
345Supplying and laying 25 mm x 6 mm CU earth strip ISI marked on surface or in recess for connection etc as required.
346Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required.
347SUBMAIN.
348Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.
349Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.
350CABLE .
351Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of4 core 16 sq.mm Aluminium on surface as required.
352Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of 3Core 6 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation , sand cushining protective covering and refilling the trench etc. as required.
353END TERMINATION
354Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.
3554C x 16 sq.mm
356EARTHING
357Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required.
358Supplying and laying 25 mm x 6 mm CU earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required.
359Supplying and laying 25 mm x 6 mm CU earth strip ISI marked on surface or in recess for connection etc as required.
360Providing and fixing 8 SWG CU wire on surface or in recess for loop earthing as required.
361EXTERNAL LIGHTING(MAKE-HAVELS/PHILLIPS/ ORIENT)
362Supply &fixing of 8W LED Bollards light.
363Supply &fixing of 12W LED Spike light.
364Supply &fixing of 6W LED Gate Light.
365Supply &fixing of Decorative ornamental LED POST TOPlight .
366Supply &fixing of 60W LED Streetlight with 6M GI POLE and all accessories.
367Supply &fixing of 40W LED outdoor type Strip light 5mtr long roll.
368Supply &fixing of LED Boundery Wall light.
369Supplying and fixing ofof 50mm G.I pipe (Medium Class) along with accessories ingroundincluding cutting & making good the sameas required.
370250KVA S/S.
37111KV OH Line & SS with 250KVA Transformer
372Supply of all materials, labour and construction of 11-KV overhead line from tapping point of CESU with 10.0 metre long200mmx100mm Joist pole ( 200 ISMB) , 55-sqmm AAAC conductor complete with required insulators, cross arms, stays, struts, guarding complete as per site requirement and direction of Engineer-in-charge.
373SUB STATION DP WITH 250KVA Transformer
374Supply, installation testing and Commissioning of 11/0.4KV Sub station DP structure made out of 10.0 metre long ISMB 200 joist pole with 400 x 400 x 6mm base plate & one set of 11-KV 400 Amp horizontal gang operated A.B. switch ,11KV 400 Amp horn gap fuse ,3nos. 12KV lightning arrestors etc complete with associated structural members made out of fabricated m.s. channels, angles etc as per the approved drawing including cost of clamp, nut bolts, painting with 2 coats of red oxide primer & 2 coats of aluminium paint including excavation of pole pit in all kinds of soil, PCC base padding,back filling of the pit with 1:3:6 PCC, painting with two coats of redoxide primer & two coats of aluminium paint, construction of brick masonary couping, fixing of danger board etc complete as required including fencing around the DP Sructure with M.S grille
375Supply, delivery, of energy efficient low loss 250-KVA, 11/0.415 KV Copper wound ONAN Dyn-11 transformer complete including first filling of transformer oil.
376Installation, testing and commissioning of energy efficient low loss 250-KVA, 11/0.415 KV Copper wound ONAN Dyn-11 transformer complete including first filling of transformer oil.
377Supply, laying, installation, testing and commissioning of 3Core 95sqmm 11KV XLPE( E) cable
378Supply of material , installation, testing and commissioning of 3Core 95sqmm 11KV XLPEoutdoor jointing kit
379Substation yard devlopment including barbared wire fencing,T/R plingth ,M.S grille,& spreading of Hard granite metal,sand etc as required.
380PANELS
381Supply, installation and testing of L.T. outdoor/ indoor floor mounted type distribution boards made out of 2mm thick CR sheet metal cubicle, duly acid treated for derusting, primered and painted with 2 coats of enamel paint of approved shade; dust, damp & vermin proved; having hinged door and compartmental arrangementfor eachequipment& busbar chamber onthe top of the panel running horizontally; having provision for cable/ conduit entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISSandasperspecial conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge.
382Outdoor Sub Station Panel
383Panel having 420A 3P MCCB (50KA) -1 No as incomerwith suitable arrangement for cable termination ofcomplete duly factory wired as per SLD
384CABLES
385Supply, laying & testing offollowing sizes XLPE insulated, PVC sheathed, strip/ wire armoured aluminium conductor power cable of 1100 volt grade laiddirectly inground/ onsurface ofwall/column/ existing RCC/ stone ware/ through G.I. pipe/ hume pipe as the case may be including excavation of earth in all kinds of soil & rock, sand cushioning, protectivecovering, refillingthetrenchwithsand and brick covering but excluding the cost of G. I. pipe/ hume pipe and cable end terminationcomplete with making good the damages caused as required and as per direction of Engineer-in-charge.
386Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of3.5core 240 sq.mm direct in groundincluding excavation , sand cushining protective covering and refilling the trench etc. as required.(Make-polycab/RR Kable/Rhino cable)
387Supply of materials and end termination of following cables including supply of single compression brass cable glands, cable sockets etc complete as required and as per direction of Engineer-in-charge.
3883.5C x 240 sq.mm
389Construction of Man hole chamber for cable pulling / crossing of size [600mm(W) x 600mm(D)] complete including with suitable size of Hume pipe, base foundation with C.C 1:3:6, 250mm brick walls, filling the inside area with sand, removableRCC slab for chambers with C.C 1:2:4 on the top, wall and top plastering etc complete as required
390Providing , layingand fixing ofof 100mm diaPVC Pipe (8kg/psi) along with G.I /PVC accessories inground for road crossing including trenching (450mm) and refillingas required.
391EARTHING
392Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required.
393Supplying and laying 25 mm x 6 mm CU earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required.
394Supplying and laying 25 mm x 5 mm CU earth strip ISI marked on surface or in recess for connection etc as required.
395Earthing with G.I earth pipe 3 meter long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangment and watering pipe etc with charcoal and salt as required
396Supplying and laying 25 mm x 6 mm G.I earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required.
397Supplying and laying 25 mm x 5 mm G.I earth strip ISI marked on surface or in recess for connection etc as required.
398Providing and fixing 6 SWG G.I. wire on surface or in recess for loop earthing as required.
399Supply of material & laying under ground/ floor/ wall including making end termination and testing of following size of Cu/G.I. wire for loop earthing of equipments, switch boards & panels as required comlete as per direction of Engineer-in-charge.
4008SWG HDBC Wire on surface or in recess for loop earthing as required.
4018 swg G.I wire on surface or in recess for loop earthing as required.
402HVAC
403Supply of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling only, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. with refrigerant-cooled PCB for better performance complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 49°C ambient temperature without tripping. The unit shall be suitable to work on 380-415 V, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. MS/GI powder coated stand with vibration isolation pads. The ODU shall have low noise condenser fans with external static pressure of the outdoor unit shall be more then 75 Pa to avoid hot air recirculation, auto address setting, auto check function for connection error and complete with indoor and outdoor units with individual controller and with fittings etc. The compressor and VRV/VRF Outdoor make should be same having compressor motor of 6 pole. The unit shall also have feature to automatically modulate the evaporative temperature between 6 deg C to 11 deg C with respect to load for better comfort and energy efficiency.The Unit should have free phase technology so that unit can work in case ofphase reversal also without tripping of units.Make-LG,Daikin or equevalents
40452 HP
40548 HP
40660 HP
407Supply of following minimu capacity 4-way/ round flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with cordless remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump, cassette grill, insulation, necessary supports, vibration isolation etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. All 4 louvers of the unit shall be independently adjustable for positiion as per user preference.Make-LG,Daikin or HITACHI.
408Nominal Capacity 1.05 TR
409Nominal Capacity 1.3 TR
410Nominal Capacity 1.6 TR
411Nominal Capacity 2.07TR
412Nominal Capacity 2.6TR
413Nominal Capacity 3.3TR
414Nominal Capacity 4.1TR
415Nominal Capacity 4.6TR
416Wall Mounted Type Series
417Nominal Capacity 1.6TR
418Lifting, Shifting, Installation, Testing & commissioning of VRV Out Door units.Make-LG,Daikin or HITACHI
419162 HP.Make-LG,Daikin or HITACHI
420Lifting, Shifting, Installation, testing & commissioning of of The Indoor units.Make-LG,Daikin or HITACHI
4214 Way/ Round Flow Cassette
422Hiwall Units
423Supplay, Installation, Testing& Commissioning of the Copper refrigerant pipes with 19mm/13mm with nitrile rubber tube insulation of following sizes.Make-LG,Daikin or HITACHI
424Gas line with 19mm thick insulation and Liquid with 13mm thick insulation
42541.3mm
42634.9mm
42728.58mm
42822.2mm
42919.05mm
43015.9mm
43112.7mm
4329.52mm
4336.4mm
434Supply & Installation Testing and Commission of Control wiring of 2 core x 1.0 sqmm copper cable through suitable conduits in between indoor and outdoor units.Make-LG,Daikin or HITACHI
435Supply, Installation, Testing and Commissioningof hard PVC drain pipe with 9mm thick nytrile tube insulation.(With necessary Lbow, Sockets & Reducers.)Make-LG,Daikin or HITACHI
43625mm inner dia
43732mm inner dia
43840mm inner dia
439Supply and Commissioning of VRF systems including additional referigernt R410Ain all respect to complete the systemas per site requirements. Make-LG,Daikin or HITACHI
440LIFT
441Providing & Fixing of 1no. 544 Kgs (8 person) gearless elevator having automatic rescue operation with 4 stop, full collective operation with/without attendant, made of stainless steel car panel with rear side of the lift having glass panel with SS handrails and 1000mm width stainless steel door (opening on one side in all stop) complete in all respect as directed by Architect/Engineer-In-Charge. The rate includes all complete with materials, labour, T&P, taxes etc. Make Mitshubishi, OTIS,JOHNSON or THYSENKROP or equevalents approved as per Technical & Manufacture"s specification.
442FIRE FIGHTING WORKS
443A.FIRE PROTECTION WORK(A-1) FIRE EXTINGUISHERSProviding & Fixing of fire extinguishers with necessary accessories, stand, trolley, etc.6 Kg ABC (Powder Type) Fire Extinguisher. In HP Mild Steel Cylinders ISI markedfitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683safex/minimax/safeguard/FIRE TIPS EQV
444ISI marked (IS:15683) portableAFFF Mechanical foamfire extinguisher, Foam type capacity 9 liters with gun metal cap and nozzle and complete in allrespectsincluding initial fill and wall suspension bracketssafex/minimax/safeguard/FIRE TIPS EQV
445ISI Marked portable fire extinguisher, 4.5 kg CO2 type fire extinguishers complete in all respect including initial fill and wall suspension brackets & shall conform tolatestIS 15683safex/minimax/safeguard/ FIRE TIPS
446Supplying and installing at approved location approved make fire buckets (3 nos./set) of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and black on the bottom, inscribed with letters "" FIRE"" in black and gold with dry clean fire sand. The scope shall also include the stand for mounting the sand bucket.
447(INTARANAL HYDRANT SYSTEM ) FIRE RISER: Supplying, installation testing and commissioning of the following. ‘C" class MS pipe as per IS1239 with welded / flanged / screwed joints and with heavy clamps, hangers, brackets or pipe supports (all with screwed/welded joints) as required including MS pipe of shorter lengths, tapering connecting pieces, short or long bends, forged specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. Complete to make the system operative as required by LFA / TAC authorities.The pipes will have to be laid and fixed on walls, ceilings, into brick walls or RCC with lead anchor fasteners. The work includesmaking holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the Consultant/Client and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for over ground / overheads pipes.
448150mm.Jindal/TATA
449100 mm Jindal/TATA
45080 mm Jindal/TATA
451Supply, installation, testing and commissioning of ci Butterfly valve of PN 1.6 rating with metal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required: 150 mm.Kartar/H-sarker/zoloto
452SIZE 100 MM DIA
453Providing and fixing Single headed hydranthaving outlet of 63 mm dia (2.1/2”) N.B. hydrant (IS:5290) landing valve in Stainless Steel Morris Pattern instanteous coupling type TAC / LFA approved & ISI certified heavy type hydraulically tested to 1.5 times working pressure with necessary nuts, bolts etc. Kartar/Newage/ ISI MARK
454Providing & fixing 63mm diaRRL hose pipe as perIS 636 TYPE A TAC/ LFAapproved of 15 mtr lengthof approved pattern and size including SS male and female Coupling duly bound withcopper wireetc. complete. CRC/Newage
455Providing and fixing fire hose cabinet to house fire hydrant & hose, including all other related accerrories fabricated from M.S. sheet (2mm thick) of fully welded construction having front door with locking arrangement, partially glazed with 4 mm thick glass. Cabinet shall be powder coated & painted with post office red colour of size as approved by the engineer-in-charge to house 15 mtr.x2 nos. hoses. The hose box size is 750 mm x 600 mm x 300 mm.
456Supplying & fixing first aid fire hose reel of thermoplast braided suitably reinforced 20 mm size & 30 m standard length with 5 mm tapering branch nozzle, 25mm dia. Pipe to connect to riser.Hose to be swinging type wall mounted drum & recessing into hose cabinet to suit location including fixing with lead anchor fasteners & bolts (Including drum and swivel arrangement) etc complete. (IS 884).Mitras/Newage/gilpro/ ISI MARK
457Supplying and fixing specially designed orifice plates (minimum 6 mm plate thickness)on hydrant outlets of landing valves including distant pieces of suitable size for reducing delivery pressure to 3.5 kg/ sq.cm at hydrant valve ,as required by LFA complete with necessary accessories, etc. complete.
458Providing and fixing Stainless Steel standard branch pipe dia 63 mm inlet with nozzle 20 mm dia outletconforming to IS : 903, suitable for instantaneous connections to hose coupling etc. as required: Kartar/ISI MARK
459Providing, fixing and testing forged brass 25 mm dia screwed inlet single acting air release valve with asll accessories. Kartar/newage/equivalent
460Providing, fixing and testing forged25 mm dia screwedball valve with accessories.Kartar/Zoloto/H sarker
461(A-3)EXTERNAL HYDRANT SYSTEM Supplying, installation testing and commissioning of the following ‘C’ class MSPipe IS 1239 above 150 nb IS 3589 over ground pipes and road crossing under ground with welded / flanged connection with saddles, supports (all with screwed/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends,elbows, reducers etc. Complete to make the system operative as required by LFA / TAC authorities.The above groundpipes willlaid on concrete pedestal with structural steel or Steel bracket& painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for overheads pipes and road crossing pipeswill laid through humepipe with wrapping coating.
462150 mmJindal/TATA
46380 mm dia. Jindal/TATA
464Providing and fixing hydrant valve. With flanges and accessories and supply, fixing63 mm diaSSSingle headed HydrantValve in the courtyard IS:5290Including 2 coats of approved enamel paint (red) over a coatof primer, complete with 2.1/2” ‘Morris’ pattern instaneous couplings, etc. complete. Kartar/Newage/ISI MARK
465Providing & fixingapproved63mm diaRRL hose pipe as perIS 636 TYPE A TAC/ LFA of 15 mtr. standard lengthof approved pattern and size including SS male and female Coupling duly bound withcopper wireetc. complete. CRC/Newage/ISI MARK
466Providing and fixing Stainless Steel standard branch pipe dia 63 mm inlet with nozzle 20 mm dia outletconforming to IS : 903, suitable for instantaneous connections to hose coupling etc. as required: Kartar/Winco/H sarker/ISI MARK/EQV
467Providing and fixing TAC approved fire hose cabinet to house fire hydrant & hose, including all other related accerrories fabricated from M.S. sheet (2mm thick) of fully welded construction having front door with locking arrangement, partially glazed with 4 mm thick glass. Cabinet shall be powder coated & painted with post office red colour of sizeas approved by the engineer-in-Charge to house 15 mtr.x2 nos. hoses. The hose box size is 750 mm x 600 mm x 300 mm . Newage/Winco/ Equivalent
468Supplying and fixing 4 way Fire Brigade service inlet of size 150 mm dia.with 4 No. 63mm (2.1/2") size Stainless Steelmale outlets( Stainless Steel male coupling) including metallic cover of mild steel and glass front, indicator plates complete. as required by LFA/TAC/engineer in charge kartar/FIRE TIPS/NEW AGE/EQV
469Supplying and fixing Fire Brigade draw out connection of size 100 mm dia. SSmale outlets( Stainless steel male coupling) including 100 mm dia foot valveetc. complete to be connected with fire water tank.as required by LFA/TAC/engineer in charge
470Supply and installation, testing and commissioningof Isolation Sluice valves tested to ISI marked ,PN 1.6 with CI body, bonnet & brass trim parts, & having necessary companion flanges, bolts, nuts, gasket packing and any other spares, includingindicator for open and shut position to be installedas per fire practice etc complete. 150 mm dia.kartar/Kalpan/Eqv
471Supply, installation, testing and commissioning of 0.05 cum Air Vessel25 NB Air release valve, ball valveandv pressure gauge with matching socked as per direction of Engineer-in-charge
472(A-4)FIRE PUMPS & RELATED ACCESSORIES Supplying & installing completely testing & commissioning of End Suction Back Pull Out pump set having pump speed of 2900 rpm, Pump Efficiency not less than 65%, with CI Casing, Bronze Impeller, SS 410 Shaft & Shaft Sleeve Connected through Flexible Coupling with a TEFC Sq. Cage Induction Motormounted on a common base frame fabricated in MS Channel. Packing has to be of Mechanical seal. It has to be inclussive of all the pump accessories.The pump shall be capable of giving not less than 150% discharge at a head not less than 65% of the rated head. Motor to be of continuous rating Motor to be suitable for 415V, 50Hz, AC supply of 35 KWratingfor the above pumps. Motor shall accept +/-10% variation in voltage and +/- 3% variation in frequency. It has to be of IE2 efficiency class.etc. complete.Pump - Motor : Discharge : 2280 LPM, Head-70 mtr.kirloskar/Wilo/EQV
473Supplying, installing, testing and commissioning of End Suction Back Pull Out pump set having pump speed of 2900 rpm, Pump Efficiency not less than 25%, with CI Casing, Bronze Impeller, SS 410 Shaft & Shaft Sleeve Connected through Flexible Coupling with a TEFC Sq. Cage Induction Motor mounted on a common base frame fabricated in MS Channel.Motor to be suitable for 415V, 50Hz, AC supply of 5 to 11 KWratingfor the above pumps. Motor shall accept +/-10% variation in voltage and +/- 3% variation in frequency. It has to be of IE2 efficiency class.Packing has to be of Mechanical seal. It has tio be inclusive of all the pump accessories complete . The scope shall also include necessary coupling, coupling guard, base frame, foundation bolts etc. completePump - Motor: Discharge: 180 LPM, Head: 70 mtr. kirloskar/Wilo
474Supply, installation, testing & commissioning of diesel Engine driven common stand by pump, horizontal centrifugal end suction typewith mechanical seal and capable to deliver 2280 LPM , to ensure a minimum pressure of 3.5 Kg/Sqcmat thefarthest or topmost hydrant / sprinkler. Firepumpshall have C.I. casing, CS diffusers,bronze impeller (hard finished and dynamically balanced) andS.S. (304) Shaftwithmechanical seal. The installation shall be complete with necessary pressure gauge with gun metal shut off cock on suction & delivery side. The pump shall coupled to not less than35 kw of Diesel engine radiator water cooled type with speed not more than 1800 RPM and complete set shall be mounted on common base frame. Batteries & battery leads with stand, Fuel tank ( for 6 Hrs. operation ) with stand & gauge glass, Fuel piping with valves. The quoted rate shall includes radiator water cooling piping(if required) coupling guard and other standard accessories (as recommended by manufacturer) and foundation bolts, etc. complete. Pump shall be capable of furnishing Not less than 150% of rated capacity at a head of Not less than 65% of the rated head.The shut off head shall Not exceed 120% of rated head. flexible coupling, coupling guard,anti vibration pad& exhaust pipe connection complete as required. Pump - diesel engine: Discharge:2280 LPM, Head: 70 mtr. kirloskar/Wilo/EQV
475MCC for Fire Pumps :Design, manufacture, supply ,installation, testing and commissioning of following Automated Fire panel suitable for 415V, 3 phase, 4 wire, 50 hz power distribution system. The panel should be indoor, free standing, floor mounting, sheet metal clad, Cubicle, dead front, dust and vermin proof, compartmentalized design fabricated out of 2mm CRCA sheet complete with Cu busbars, a separate earth bus bar to be provided through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a modular multitier arrangement, adequate size cable alley, painting, earthing numbering, damper plate etc. as required as per direction of engineer-in-charge and as per local Fire Authority requirement.The panel shall be fabricated by only CPRI approved manufacturer As per the details below INCOMING 1 No 200A FPMCCB (50 KA), 1 Set of 400 Amps. TPNCu. Bus bars with color coded heat shrinkable PVC sleeves. Indicator R,Y,B,ON,OFF,TRIP. Ammeter LCD type display+3 CTs,Voltmeter LCD type displayOUTGOINGFEEDER FOR ElectriPUMPS - 01 No :01 No160 A TP MCCB, withstar delta Starter contactor and OLR ratings as per type 2 co-ordination,with digital ammeter, voltmeter, ON,OFF push button, local remote switch,auto manual seclector switch etc. FEEDER FOR JOCKEY PUMP - 01 No:01 No32 A TP MCCB, withstar delta Starter contactor and OLR ratings as per type 2 co-ordination, withDigital Ammeter,voltmeter, ON,OFF push button, local remote switch, auto manual selector switch etc. DIESEL ENGINEPUMP - 01 No a) 25Amps DPMCB - 01 No( b) Battery charger with transformer with rectifier resistance DC ammeter, DC voltmeter, Trickle / booster / off selector switch - 1 No (c) 1 set of indicating lamps for the following : 1. Phase indication 2.Battery charger on 3.Over load relay 4. DC supply on 5.Control switch on 6. Engine fails to start7. Pump on8. Low oil pressure 9. High water temperature10. Auto manual selector switch (d) 1 sets of push button stations for the following : 1. Engine Start 2. Engine Stop 3. Engine - hooter ACK 4. Engine - fault reset(e) Selector switches (Engine control, mode selector)-1 No ( f) Auxiliary relays / contactors / timer for sequence operating for starting and stopping of the engine - 1 set (g) Hooter for audio alarm (Industrial type) - 1 No. (h)Automatic source transfer Relay with 3 attempt starting,High Low Lube pressure, timers and relays as required and suitable contactor.All the components shall be housed in a common cubical made of 2mm CRCA sheet with required stiffeners ( if required). The panel shall be powder coated of approved color both inside & out side. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height. Also panel shall have sufficient (min. 10 Nos) NO/NC contacts for extending the status( annunciation) of fire pumps to the Fire alarm panel.CPRI Approved
476Earthing with G.l. earth plate 300 mm X 300 mm X 6 mm thick including accessories, and providing masonry "enclosure with cover plate having locking arrangement and watering pipe of 1.5 meter long etc. with charcoal/ coke and salt as required.
477Supplying and laying 25 mm X 5 mm G.l strip at ground as strip earth electrode, including connection/ terminating with G.l. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.l. nut bolt & spring washer spaced at 50mm).
478CABLESupply, laying testing and commissioning of L.T. Al. XLPE armoured / unarmoured cable confirming to IS : 7098 Part - II as per direction of engineer-in-charge as per the description given below:
4793.5 C x 95 sq.mmPolycab/kei/finolex/havells
4804 C x 50 Sqmm.Polycab/kei/finolex/havells
48112 C x 2.5 Sqmm.(Cu) Polycab/kei/finolex/havells
4824 C x 16 Sqmm.Polycab/kei/finolex/havells
483CABLE END TERMINATION Supply, fixing, connection, testing and commissioning of double compression brass cable glands and crimping type lugs / sockets with necessary tools and equipments as specified in specifications and IS. The glands and lugs / sockets shall be suitable for cable size and type mentioned above. The job also includes, if necessary, supply and fixing of extension busbar of same material on circuit breaker /FSU or panel board terminal / connector to connect morethan oneno. of parallel cables or to connect higher sizecable to lower size unit. The job also includes earthing the glands and armour of the cable with common earth bar or flexible copper mesh.
4844C x 95 sq.mm
4854 C x 50 Sqmm. Polycab/finolex/havells
48612 C x 2.5 Sqmm.
4874 C x 16 Sqmm.
488CABLE TRAY Supplying and installingof perforated G.I.sheet cable tray with necessaryiron suspension supports, anchor fasteners etc. complete. Maximum height of suspension shall Not exceed 500 mm.Size of the tray is 40mm x 200mm x 40mm and 2mm thick.
489Providing and fixing Power wiring with 2 core x 1.5 sq.mm. PVC armoured copper cable for wiring pressure switches, etc. Including all required material and labour, terminations, etc. Complete.Polycab/ RR Cable
490Supplying, installation testing and commissioning of the following .‘C’ class MS Pipe as perIS:1239 above 150 nb IS 3589 for over ground pipes with flanged/ welded and with heavy clamps, hangers, brackets or pipe supports (all with flanged/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, MS specials like sockets, union nuts, elbows, reducers, plugs, Tees, bends,etc. Complete to make the system operative as required by LFA / TAC authorities the pipes will have to be laid and fixed in trenches on walls, ceilings, into brick walls or RCC with lead anchor fastners. The work includes excavation in all types of soils and back filling and making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the engineer-in-charge and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for overheads pipes
491200mm Jindal/TATA
492150mm
493100 mm
49480 mm
49550 mm
496Providing, installing and commissioning C.I. flanged "Y" type Strainer with SS mesh, suitable flanges, nuts, bolts, gaskets etc. complete (ISI).200 mmKartar/Zoloto/H sarker /EQV
497Supply and installation, testing and commissioningof double flanged Isolation Sluice valves conforming to IS 14846 tested to ISI marked ,PN 1.6 with CI body, bonnet & brass trim parts, & having necessary companion flanges, bolts, nuts, gasket packing, support and any other spares, includingindicator for open and shut position
498Size :200 mm Kartar/Kalpana/EQV
499Size :150 mm Kartar/Kalpana/EQV
500Size :100 mm Kartar/Kalpana/EQV
501Size :50 mm Kartar/Klapana/EQV
502Supply, installation, testing and commissioning of ci Butterfly valve of PN 1.0 rating with metal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required:
503Size :150 mmKartar/Kalpana/EQV
504Size :100 mm Kartar/Kalpana/EQV
505Size :50 mm Kartar/Kalpana/EQV
506NRV conforming to IS 5312 (swing type) or to API 594/598 (dual plate check type) with CI body & brass trim part, PN 1.6 having necessary companion flanges, CS hardwares. Gaskets, arrow indicating direction of flow, etc. complete. It shall be ISI Marked and approved make
507Size : 150 mmKartar/Kalpana/EQV
508Size :50 mmKartar/Kalpana/EQV
509Supply, installation testing and commissioning pressure switch assembly with interlocking of pumps. Indfos/Danfos/equivalent
510100 mm dial Pressure gauge with Syphon tubing, isolation valve & mounting accessories complete Range: 0 - 10 kg/sq.cm.H-Guru/waree/ fiebig
511Supplying, installing, testing and commissioning of hydraulically operated Sprinkler control valve, with water motor gong bell and trims as required, pressure gauges, drain valves, ball valves, check valves, strainers etc. complete.as per NBC/LFA/direction of engineer-in-charge Size : 150 mm.HD/Viking/tyco
512SITC ofwater level indicator with panel, with probe & all control wiring to operate the system automatic/manual & shall prevent the pump from dry running as per NBC/LFA/ direction of engineer-in-charge
513Ball valve of 15 mm diaKartar/H sarker/EQV
514(A-5)TERRACE PIPING & ACCESSORIESSupply, installation, testing and commissioning of ci Butterfly valve of PN 1.6 rating with metal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required:
515Size : 150 mm
516Size : 100 mmKartar/H sarker /EQV
517NRV conforming to IS 5312 (swing type) or to API 594/598 (dual plate check type) with CI body & brass trim part, PN 1.0 having necessary companion flanges, CS hardwares. Gaskets, arrow indicating direction of flow, etc. complete. It shall be ISI Marked and approved make Size : 150 mm Kartar/H sarker/EQV
518100 mm dia Kartar/Kalpana/EQV
519Supplying, installation testing and commissioning of the following ‘C’ class MS Pipe as perIS:1239 for overhead pipes with flanges welded and with heavy clamps ,hangers, brackets or pipe supports (all with screwed/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, MS specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. Complete to make the system operative as required by LFA / TAC authorities the pipes will have to be laid and fixed in trenches on walls, ceilings, into brick walls or RCC with lead anchor fasteners. The work shall beto the satisfaction of the engineer-in-charge and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for overhead pipes
520Size : 150 mm Jindal/TATA
521Size : 100 mm Jindal/TATA
522(A-6)SPRINKLER SYSTEMSupplying, installation testing and commissioning of the following‘C’ class MS Pipe as perIS:1239 for overhead pipes with fittings & flanges including pipe of shorter lengths, tapering connecting pieces, short or long bends, MS specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. Complete to make the system operative as required by LFA / TAC authorities the pipes will have to be laid and fixed in trenches on walls, ceilings, into brick walls or RCC with lead anchor fasteners. The work shall beto the satisfaction of the engineer-in-charge and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for overhead pipes.
523Size : 150 mm Jindal/TATA
524Size : 100mmindal/TATA
525Size : 80 mmindal/TATA
526Size : 65 mm indal/TATA
527Size : 50 mmindal/TATA
528Size : 40 mmindal/TATA
529Size : 32 mmindal/TATA
530Size : 25 mmindal/TATA
531Supplying, installing, testing and commissioning of standard response Sprinkler quartzoid bulb type with 15mm screwed end connection of68 deg. C. temperature rating, K 80 and orifice shall Not be less than 3 mm.Pendent sprinkler HD/Viking/tyco
532Supplying, installing, testing and commissioning oftest valve and complete accessories like tees,elbows flanges etc.as per NBC/LFA/direction of engineer-in-charge.
533Test assembly
534Test Valve (25 mm)
535Drain Pipe of 25 mm dia.Jindal/TATA/EQV
536Supply, installation, testing and commissioning of ci Butterfly valve of PN 1.6 rating with metal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required:
537Size : 150 mmKartar/Zoloto/H sarker/EQV
53850 mm (Drain Ball type valve for each riser / drain downtake) KartarZoloto/ H sarker
539Supply & installation of approved make flow switch on sprinkler header on each floor, operating at 24-V with all accessories & hardwares as per NBC/LFA/direction of engineer-in-charge.Honeywell/Equivalent /EQV
540(A-7)SIGNAGES Supplying andinstalling of in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC reflective self adhesive vinyle painted foam board, complete with mirror fasteners.Signage with printed"IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" of 1.5cm height letters in red with white back ground. The size of the board shall be 25cm x 30 cm and shall be fixed at the height of 2 mts. from finished floor near Manual call points.
541Floor identification signage ( i.e., GROUND FLOOR …etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting color from back ground. Size shall be 15cm x 60cm.
542Fire Exit signageat each stair on every floor, indicating the direction of fire exit, lettering size shall be 7.5 cm with contrasting color from back ground. Size shall be 15cm x 60cm.
543Supplying and installing of in position the signages " FIRE ORDER" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerized cut, PVC Non-reflective self adhesive vinyle painted foam board of 3" x 4". as per BIS Specification. A) alert the security at security room by actuating manual call point located at strategic locations. B) evacuate the occupants by using fire exits and emergency exits only and assemble at various assembly points.(C) if possible try to extinguish the fire by using nearest / suitable portable extinguisher or water from nearest wet riser.D) be calm and do not give any room from panic, walk, do not run.(E) if you encounter serious difficulty in evacuation, flat and try to attract attention of rescue team.
544b.Action by security/reception upon receipt of information through fire alarm or fire detectors or by using public address system.(A) alert the occupants by using public address system. B) inform fire control through any one of the following phone numbers: 101 /(local numbers)C) refer evacuation plan from evacuating standard people. D) guide the fire force, on their arrival to the seat of fire.E) in case of the casualties, call ambulance by dialing number……..Phone : -----------------------Fax : ---------------------------- as per BIS Specification.
545Supplying andinstalling of in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC reflective self adhesive vinyle painted foam board, complete with mirror fasteners. as per BIS Specification.
546Fire hose reel
547Fire extinguishers
548Analogue addressable Main fire alarm panel
549Sprinkler control valves
550MCP’s
551(B) ANALOGUE ADDRESSABLE FIRE DETECTION AND ALARM SYSTEMSupply, installation, testing and commissioning of Main Fire Alarm Control Panel (FACP), the panel shall be addressable analogue fire detection and alarm type with capacity of 2 loops complete with all accessories and battery back up for 48 hours in standby mode and 15 minutes in alarm condition. The panel shall have minimum of 80 character LCD display. Each loop shall support 99 analog / addressable devices and 99 modules minimum as system capacity. The panel shall have TCP / IP facility. The panel shall be as per technical specification. The panel shall be UL/EN/FM approved. The quoted rate shall inclusive ofBacnet/Modbus interface for fire alarm panel with complete accessories. Honeywell/Cooper/Edward/Siemens/Ravel
552Supply, installation, testing and commissioning of Analogue Addressable multi sensor smoke,heat multi criteria detector with standard base and other accessories as required. The detector shall be UL/EN/FM approved.Honeywell/Cooper/Edward/Siemens/Ravel
553Supplying, installing, testing and commissioning of addressable Manual call pointwith built in Monitor Module, all accessories etc., complete. The device shall be UL/EN/FM approved.Honeywell/Cooper/Edward/Siemens/Ravel
554Supplying, installing, testing and commissioning of Isolator module with all accessories etc., complete. The device shall be UL/EN/FM approved.Honeywell/Cooper/Edward/Siemens/Ravel
555Supplying, installing, testing and commissioning of addressable monitor Module, all accessories etc., complete. The device shall be UL/EN/FM approved.Honeywell/Cooper/Edward/Siemens/Ravel
556Supplying, installing, testing and commissioning of addressable Hooter Cum Strobeat 85 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication with all accessories etc., complete. The device shall be UL/EN/FM approved. Honeywell/Cooper/Edward/Siemens/Ravel
557Supplying, installing, testing and commissioning of 2C x 1.5 sq. mm, Twisted Pair PVC insulated FRLS Armored Cable with Accessories confirming to IS standards and specifications. The quoted rate shall includes ofAcrylic Fire stop Sealant in the opening for cablespassing throughfire compartment walls of RCC floors, masonry walls to provide up to 2 hours fire rating.Polycab/kei/finolex/havells/
558(C) EMERGENCY EVACUATION SYSTEM/PUBLIC ADDRESS SYSTEM Supplying, installing, testing and commissioning of12 Watt wallmounted speakers with built in line matching transformer, grill flush mounting type in side the utility rooms.Honeywell/Bosch/Ahuja/Ecler
559Supplying, installing, testing and commissioning solid state Amplifier of 450W RMS out put in rack, including necessary control wires, jocks etc. complete.Honeywell/Bosch/Ahuja/Ecler
560Supplying, installing, testing and commissioning of P.A. Console 8 zone shall expandable up to 60 zones , with priority module micro processor based, mixing amplifier, with 6 zone for suitable selection module, power supply unit & goose neck micro phone etc.Honeywell/Bosch/Ahuja/Ecler
561Supplying, installing, testing and commissioning of P.A. Call station of 8 zones with priority module micro processor based & goose neck micro phone etc shall be located in the reception / security for the announcement necessary communication cable/CAT 6 shall be considered from PA controller to call station .Honeywell/Bosch/Ahuja/Ecler
562Supplying, installing, testing and commissioning of 12" Rack 650mm depth, 16U high amplifier rack assembly made of aluminum channel equivalent to euro rack system, with side and rear panels made of 14 swg powder coated sheet steel front transparent persplexdoor and with rails, rollers & bearings. Fans shall provided at the top for ventilation side panels will be ventilated type. The rack shall be powder coatedof approved color and spare "U" shall be covered with blank panels.Honeywell/Bosch/Ahuja/Ecler
563Supplying, installing, testing and commissioning of 2 runs of 40 strand and each of0.2 mm thick, Twisted Pair PVC insulated FRLS unarmored Cable with Accessories confirming to IS standards and specifications. The quoted rate shall includes ofAcrylic Fire stop Sealant in the opening for cablespassing throughfire compartment walls of RCC floors, masonry walls to provide up to 2 hours fire rating. Polycab/kei/finolex/havells
564Supplying, installing, testing and commissioning approved make PVC FRLS conduits on ceiling / wall / floor etc. complete with accessories like, Junction boxes, Collars, Bends etc. 20mm dia.
565P.H. WORK Supplying allmaterials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes confirming to ASTM-D- 1785/89 (Sch-80) and pipe fittings of the following nominal borewith clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer-in-charge.
566First floor
56720 mm CPVC (sdr-13.5) pipes (Oriplast/Supreme)
56825 mm CPVC(sdr-13.5) pipes (Oriplast/Supreme)
56932 mm CPVC sdr-13.5 pipes (Oriplast/Supreme)
57040 mm CPVC sdr-13.5 pipes (Oriplast/Supreme)
57150 mm UPVC sch-80 pipes(Oriplast/Supreme)
572Second floor
57320 mm CPVC (sdr-13.5) pipes (Oriplast/Supreme)
57425 mm CPVC(sdr-13.5) pipes (Oriplast/Supreme)
57532 mm CPVC sdr-13.5 pipes (Oriplast/Supreme)
57640 mm CPVC sdr-13.5 pipes (Oriplast/Supreme)
57750 mm UPVC sch-80 pipes(Oriplast/Supreme)
578Third floor
57920 mm CPVC (sdr-13.5) pipes (Oriplast/Supreme)
58025 mm CPVC(sdr-13.5) pipes (Oriplast/Supreme)
58132 mm CPVC sdr-13.5 pipes (Oriplast/Supreme)
58240 mm CPVC sdr-13.5 pipes (Oriplast/Supreme)
58350 mm UPVC sch-80 pipes(Oriplast/Supreme)
584supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings etc. all complete as per P.H. specification and direction of Engineer-in-charge.
585First Floor :- 250 mm thick wall
586Second Floor :- 250 mm thick wall
587Third Floor :- 250 mm thick wall
588Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thickfor passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes afterinsertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of theEngineer-in-charge.
589First Floor :- 250 mm thick wall
590Second Floor :- 250 mm thick wall
591Third Floor :- 250 mm thick wall
592Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the E.I.C.
593First Floor
594Second Floor
595Third Floor
596Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer-in-charge.
597Supplying all materials, labour, T&P and fixing standard sized two wayBib cock ofHindware/Jaquar/Parrywareof approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP Two waybib cock with Flange Jaquar FLR-CHR5053N.
598Supplying all materials, labour, T&P and fixing standard sizedBib cock ofHindware/Jaquar/Parrywareof approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge.15mm dia. nominal bore Long body Bib Cock JaquarFLR-CHR5163
599Supplying all materials, labour, T&P and fixing standard sizedBib cock ofHindware/Jaquar/Parrywareof approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge.15mm dia. nominal bore Short body Bib Cock JaquarFLR-CHR5037N
600Supplying all materials, labour, T&P and fixing standard sized15mm dia angular Stop cock of Hindware/Jaquar/Parrywareof approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP angle stop cock with wall flange Jaquar FLR-CHR5053N
601Supplying all materials, labour, T&P and fixing standard sized pillar cock of Hindware/Jaquar/Parryware of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 15mm dia brass pillar cock Jaquar Continental Cat. No.- -Jaquar FLR - CHR5011N
602Fixing of 25mm dia Brass / Gun meta ball Valve confirming toIS : 781-1995 of approved makeas per specification complete as per direction of Er-in-charge.32mm dia brass or gun metal full way valve (shakti make)
603Fixing of 32mm dia Brass / Gun meta ball Valve confirming toIS : 781-1995 of approved makeas per specification complete as per direction of Er-in-charge.32mm dia brass or gun metal full way valve (shakti make)
604Fixing of 40mm dia Brass / Gun meta ball Valve confirming toIS : 781-1995 ofof approved makeas per specification complete as per direction of Er-in-charge.40mm dia brass or gun metal full way valve(shakti make)
60515mm dia PVC connection pipe 450 mm long
60615mm dia CP Extention Nipple
607Providing and fixingcircular type stainless steeljalli (grating) with hole for floor /nahani trap etc complete as per specification and direction of the Engineer in charge.
608Supplying all materials, labour, T&P and fixing Health Faucet of Hindware/Jaquar/Parryware complete with Chromium plated brass brackets fixed to wooden plugs with Chromium plated brass screws as per specification and direction of theEngineer-In-Charge.
60915mm dia CP Health Faucet of Jaquar 1.2mtr long, 8MM diaJaquar ALD-CHR577.
610Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer"s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer-In-Charge.
611In Building
612110mm diameter U-PVC SWR pipes(Oriplast type-B/Supreme)
613110mm U-PVCdoor Tee
614110mm U-PVC offset
615110mm U-PVCdoor bend
616110mm U-PVCplain shoe bend
617110mm U-PVCvent cowl
618110mm P-trap
619110mm U-PVCplain bend
620100mm S/S coupling with EPMD
621Supplying all materials,labour T&P and cutting holels through existing brick or laterite masonry wall for taking H.C.I pipes and fittings including making good the damages etc. all complete as per P.H.Specification and direction of theEngineer-In-Charge.
622250mm to 375mm thick wall
623Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern of Hindware/Jaquar/Parryware with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main etc all complete as per the specification and direction of the Engineer-in-charge.
62410 Liters capacity PVC cistern with 32mm dia flush bend.Hindware sleek fresh single flushStarwhite, Size 47.6 X 15.5 X 32.5 cm
625Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) of Hindware/Jaquar/Parryware duly embedded in cement concrete (1:4:8) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI "p" or "s" trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages etc all complete as per specification and direction of theEngineer-In-Charge.
626Hindware Orissa Pan cat no 20004 Starwhite. Size- 53x41 cm
627Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C. pan) of Hindware/Jaquar/Parryware with integral "p" or "s" trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of theEngineer-In-Charge.
628EWC with "p" / S trap plain FLS-WHT-5351/5201 (S-10) Starwhite type, size-370x650x765 mm,
629Supplying all materials, labour T&P and fixing wash basins of Hindware/Jaquar/Parryware with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered "Hot" and "Cold" with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of theEngineer-In-Charge.
630Jaquar wall hungWash Basin Size - 565mmx440x210mm, Cat -no- FLS-WHT-5801/5301Starwhite.
631Countersunk Wash Basin
632Supplying all materials, labour T&P and fixing counter sunk Wash Basin Size - 545mmx545x180mm, Cat.No. FLS-WHT-5951 with all fittings as per direction of the engineer-in -charge.
633Supplying all materials, labour, T&P and fixing Flat back large pattern urinal of Hindware/Jaquar/Parryware the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls land making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Hindware Flat back large urinal cat no-60002 starwhite,Size-37.5x39x59 cm.
634Supply and fixing all materials, labour, T & P and providing urinal partition with italian collection(pastel)- size- 75x16.5x36.5 cm Cat no-61005 etc all complete as per direction of the Engineer-In-Charge. Make-Hindware.
635Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C.sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer-in-charge.
636750mmx600mm size B.E.mirror (Alpina/Golden fish/Belgion)
637Supplying all materials, labour, T&P and fixing standard size glass-shelf of Hindware/Jaquar/Parryware with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification anddirection of the Engineer-in-charge.
638Jaquar glass shelf ACN-CHR1171 N 600mm long
639Supplying all materials,labour, T&P and fixing standard sized CP towel rail24"of Hindware/Jaquar/Parryware complete withCP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer-In-Charge
64025mmx600mm long CP towel rail (Jaguar make) ACN-CHR1111NM.
641Supplying all materials, labour, T&P and fixing standard sizedChromium Plated brasstowel ring complete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge
642Supplying all materials, labour, T&P and fixing standard sizedChromium Plated soap case ofHindware/Jaquar/Parryware complete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge
643CP soap holder (Jaguar make) ACN-CHR1131N.
644Supplying all materials, labour, T&P and fixing standard sized Robe Hook ofHindware/Jaquar/Parryware complete with all as per specification and direction of the Engineer in charge. Jaquar Robe hook AKP-ABR-35791PMI.
645Supplying all materials, labour, T&P and fixing standard sized Soap Dispensor ofHindware/Jaquar/Parryware complete with all as per specification and direction of the Engineer in charge. Soap dispense with Glass Bottle. CAN-CHR1135N.
646Providing and fixing Salem Stainless steel A ISI (18/8) kitchen sink as per IS : 13983 with C.I. Brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required. a) Kitchen Sink with drain board Nirali makesize 510 X 1040 mm bowl depth 178 mm.600X450X250
647Supplying & fixing of Matrix Set-1 Mat code-70002,EWC : (P-18) (WB 46X36 with one pair mounting brackets, EWC & cistern complete with fittings & seat cover, one no hinged rail 76 cm and 4 nos of grab rail 60cm complete with all as per specification & direction of the Engineer in charge.
648Supply all materials, labour, T&P and providing fitting & fixing (Aqua guard) pure Chill 80 PSS UV of size 750x570x1350 mm height with water storage capacity 120 liters along with 2 nos of fancets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc. all complete as per approved drawing, specification and direction of the EIC.
649Supplying all materials, labour, T&P and fixing100 mm dia wall mounted over head shower& Shower armHindware/Jaquar/Parryware including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineer-in-charge. 100 mm dia CP overhead shower with Arm (Jaquar -OHSC-1989,Jaquar SHAC 483)
650Supplying all materials, labour, T&P and fixing standard sized15mm dia Single lever Concealed Deusch mixer with provision for connection to overhead shower onlyof Hindware/Jaquar/Parrywareof approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. Concealed stop cock Jaquar FLR-CHR5227.
651Toilet Portion Civil Works
652Supplying all materials, labour, T&P and providing Mat finish tiles in floors, treads and landing on 20mm thick bed of cement mortar 1:4 (1 cement:4 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. ( tile 600cmx600cm kajaria- Fogparla or equivalent makelto be pre-approved by the Engineer in charge)
653First floor
654Second floor
655Third floor
656Supplying all materials, labour, T&P and fixing provide glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge.tile 600x300cm sizekajaria-Duren marfil or equivalent make to be pre-approved by the Engineer in charge)
657First floor
658Second floor
659Third floor
660Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
661First floor
662Second floor
663Third floor
664Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 3.00mm Expanded Polystyrone(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre"s standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter with FRP frame of size 45x90mm.(Darwaja /Exon Door make)
665First floor,Second floor,Third floor
666EXTERNAL P.H. & SANITARY WORK
667Supplying all materials, labour, T & P and constructing Gully trap chamber of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge.
668250mmx250mm with RCC cover
669Supplying all materials, labour, T & P and constructing Inspection chamber of the following inside size with CC (1:3:6) mix using 40mm size h.g. metal on bed, Ist class Fly Ash brickwork in CM (1:6) , moulding and shaping the channel inside and benching with CC (1:2:4) using 12mm size h.g. chips, 12mm thick cement plastering (1:3) finished with punning to inside , cement flush pointing (1:3) to outside , R.C.C. cover slab in (1:2:4) using 12mm size h.g. chips with RCC man hole cover , earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering ,curing, conveyance of all materials to worksite , payment of royality , taxesetc. all complete as per aproved drawing , specification and direction of Engineer-in-charge.
670Inside size 760mm x760mm x450mm
671Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class-3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer-in-charge.
672110mm dia u-pvc pipe alround concrete
673160mm dia u-pvc pipe alround concrete
674Supplying all materials, labour, T&P and constructing Man hole chamber of the following size withcement concrete (1:3:6) using 40 mm size HG metal on bed , !st class Fly Ash Brick work in CM (1:6) moulding and shaping the channel inside and benching with CC (1:2:4) mix using 12 mm size H.G chips,12 mm thick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside ,RCC cover slab in (1:2:4) mix using 12 mm size H.G chips with RCC man hole cover , earth work in all kinds of soil and refilling the cavity around the camber including watering, curing, conveyance of all materials to worksitepaymentof royalty, taxes etc. all completed as per approved drawing, specification and direction of Engineer-in-charge.
675Inside size 910mmx910mmx910mm
676addl depth of 0.30m upto 4.50m depth
677Supplying all materials, labour, T&P and constructing soakway pit of the following size with precast RCC rings joined loose, gravel backing in the rear of well steining, precast RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including cutting hole in the rings for inlet pipe,earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer-In-Charge
678RCC rings soakway pit 1.22m dia x 2.0m deep
679Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge
680Brick masonry soakway pit 1.20m dia x 2.00m deep
681BOREWELL
682Construction of 1 No production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories
683Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only
684Drilling of 200mm dia bore
68500 mtr to 30mtr
68630 mtr to 45mtr
687Drilling of 150mm dia bore
68845 mtr to above
689Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.
690Lowering of 200mm dia P.V.C casing pipes
69100 mtr to 30mtr
69230 mtr to 45mtr
693Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber "O" ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length.
694200mm dia PVC (sch-80) pipe
695Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department)
696Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge
697By DTH Rig
698Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make)
6991 H.P. Single phase/ three phase 3 stagehead renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby)
700DOL Control panel
70140mm dia steel short piece
702Well cap
70350mm size CI bracket
7042.50sqmm flat cable
70520mm dia rigid UPVC pipes
706Steel rope with cover
707Labour charges for lowering including transportation
708Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceilingand floor all complete as per specification and direction of the Engineer in charge
70932mm HDPE pipes (Finolex/Supreme make)
710B.ii- SEPTIC TANK. (200 USER)(10x4x2) mtr
711Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works up to and including 1.5 metre lift and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge.
712All type of Soil
713Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15 cm in depth : consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge.
714S. Tank
715Supplying offilling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of E.I.C.
716S. Tank
717Providing and laying plain cement concrete 1:3:6 (1 cement:3 sand: 6 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. includingtempering, curring, shuttering etc. complete all depth and height.
718S. Tank
719Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12m size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
720S. Tank
721Providing, lifting, hoisting and laying Reinforced cement concrete of M-250 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed andcleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portlandslag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.
722a) Base
723b) Wall/Beam
724c) Slab
725Supplying, straightening, cutting, bending, placing in position and binding reinforcement steel work in RCC/reinforced brick works as per drawing and specification including preparation of respective bar bending schedule and binding (Binding wire to be used as per the IS code) etc. all complete as per direction of Engineer-In-Charge.Cold Twisted bars, Thermo-Mechanically-treated bars.
726Steel
727Fly Ash bricks Masinary (1:6) (in F & P).
728First class Fly Ash Brick masonry usingF.A. bricks of size 25 cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge.
729Brick work in inlet & outlet chamber
73012mm cement plaster on internal smooth side of RCC/brick surfaces with cement mortar of mix 1:4 (1 cement : 4 fine sand) including neat cement punning & necessary scaffolding, curing etc. all complete at all floors and all heights.
731Plaster in inlet & outlet chamber
73216 mm Plastering.
733Providing 16mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) with OPC 53 grade cement finished smooth to inside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as desired by the Engineer in charge.
734Plaster in inlet & outlet chamber
735Supplying all materials, labour, T&P and providing , fitting & fixing 100mm x100mm x100 mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge.
736SW Tee
737Supplying all materials ,labour, T&P and making MS STEP IRON IN 20MM diameter MS steel bars & fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
738MS Steps irons
739OH TANK (20kld)
740Providing, lifting, hoisting and laying Reinforced cement concrete of M-250 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed andcleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portlandslag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.
741b) Wall,Beam & Column
742c) Slab
743Supplying, straightening, cutting, bending, placing in position and binding reinforcement steel work in RCC/reinforced brick works as per drawing and specification including preparation of respective bar bending schedule and binding (Binding wire to be used as per the IS code) etc. all complete as per direction of Engineer-In-Charge.Cold Twisted bars, Thermo-Mechanically-treated bars.
744b) Wall,Beam , Column & Slab
7456 mm cement plaster on internal smooth side of RCC/brick surfaces with cement mortar of mix 1:4(1 cement : 4fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights.
746Supplying all materials, labour, T&P and providing Pidifin 2K including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
747Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site.
748Supplying and fitting and fixing stainless steel 34 grade in said rail using 5mm dia 2mm thick circular pipe and balustrade 32mm x 32mm x 2mm below including welding welding with stainless steel elect rod and fixing with necessary accessories ete. complete as per direction of the Engineer-in-charge.
749Providing fitting and fixing MS cover made out of MS angle and sheet duly welding and fixing with frame and hinges along with locking arrangement of size 60cmx60cm etc complete as per direction of Engineer -in-charge.
750MH COVER
751RAINWATER HARVESTING WORK.(TWO NOS)
752Earthwork in excavation over areas (exceeding 30 cm in depth 1.5 m. in width as well as 10 sqm on plan)including disposal of excavated earth lead upto 100m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed as directed by the Engineer-In-Charge.
753Supplying, filling, spreading & leveling stone boulders of size range 50mm to 200mm, in recharge pit, in the required thickness, for all leads & lifts, all complete as direction of Engineer-In-Charge.
754Supplying, filling, spreading & leveling gravels of size range 5mm to 10mm, in recharge pit, over the existing layar of boulders, in the required thickness, for all leads & lifts, all complete as direction of Engineer-In-Charge.
755Supplying, filling, spreading & leveling coarse sand of size range 1.5mm to 2mm, in recharge pit, over the existing layar of gravels layer, in the required thickness, for all leads & lifts,all complete as direction of Engineer-In-Charge.
756Providing, lifting, hoisting and laying Reinforced cement concrete of M-200 grade as per approved designs and drawings having a minimum compressive strength (in work test) 200 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed andcleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portlandslag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.
757Supplying, straightening, cutting, bending, placing in position and binding reinforcement steel work in RCC/reinforced brick works as per drawing and specification including preparation of respective bar bending schedule etc. all complete as per direction of EIC.
758Cold Twisted bars, Thermo-Mechanically-treated bars.
759Providing and constructing brick work using Fly Ash bricks in cement sand mortar (1:4) in foundations and superstructures, sewer, drains etc. bonding, lining, levelling, plumbing, racking out joints, curing as per specifications, all materials, tools and labour complete.
760Boring/drilling bore well of required dia for casing/strainer pipe by suitable method prescribed in IS; 2800 (part-1), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-In-Charge, up to 90 metre depth below ground level.
761a) All kinds of soil 300mm dia.
762Supplying, assembling, lowering and fixing in vertical position in bore well Unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS : 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depth, as per direction of Engineer-In-Charge.
763200mm dia PVC (sch-80) pipe
764Rainwater pipe 110mm dia (Type-A)
765160 mm dia Rain water pipe
766Providing fitting & fixing RCPC cover etc complete as per direction of Engineer -in-charge.
767MH COVER
768UG TANK (50kld)
769Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works up to and including 1.5 metre lift and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge.
770All type of Soil
771Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15 cm in depth : consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge.
772Excavated earth filling
773Supplying offilling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of E.I.C.
774UG Tank
775Providing and laying plain cement concrete 1:3:6 (1 cement:3 sand: 6 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. includingtempering, curring, shuttering etc. complete all depth and height.
776UG Tank
777Providing, lifting, hoisting and laying Reinforced cement concrete of M-250 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed andcleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portlandslag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.
778a) Base
779b) Wall/Beam
780c) Slab
781Supplying, straightening, cutting, bending, placing in position and binding reinforcement steel work in RCC/reinforced brick works as per drawing and specification including preparation of respective bar bending schedule and binding (Binding wire to be used as per the IS code) etc. all complete as per direction of Engineer-In-Charge.Cold Twisted bars, Thermo-Mechanically-treated bars.
782Steel
783First class Fly Ash Brick masonry usingF.A. bricks of size 23cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge.
78412mm cement plaster on external RCC/brick surfaces incement plaster 1:6 (1 cement : 6 coarse sand) including necessary scaffolding, curing etc. all complete at all floors and all heights.
78516mm cement plaster on internal smooth side of RCC/brick surfaces with cement mortar of mix 1:6 (1 cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights.
7866 mm cement plaster on internal smooth side of RCC/brick surfaces with cement mortar of mix 1:4(1 cement : 4fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights.
787Providing and fixing Steel work welded in built up section/framed (including M.S. angle,plate, sq.bar, flat, m.s.tubular section, Heavy type hinges) work incuding cutting, hoisting, fixing in position and applying apriming coat of approved steel primer, two or more coats of synthetic enamel paint with approved make and brand in grating, frames, guard bar, ladder, railings for balconies and straircase, brackets, gates and similar works as per direction of Engineer-In-Charge. (All structural steel contractor"s own supply).
788Providing & Applying priming coat with Cementbase primer of approved brand and manufacture onplaster/putty surface as per the instruction of Engineer-In-Charge at all elevations and all heights including all material & labour complete.
789Providing and applying to outside walls with two or more coats ofAnti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-in-charge at all elevations including all material labour complete. in all floors and all heights.
790Providing & painting Two coats of Distempering paint with 1st quality oil bound washable distemper of approved brand and manufacturer to give an even shade as per the instruction of Engineer - In- Charge at all elevations including all material & labour complete.
791Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer - In-Charge at all floors and all heights including all material & labour complete.
792Supplying all materials, labour, T&P and providing Pidifin 2K including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.
793Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site.
794Supplying and fitting and fixing stainless steel 34 grade in said rail using 5mm dia 2mm thick circular pipe and balustrade 32mm x 32mm x 2mm below including welding welding with stainless steel elect rod and fixing with necessary accessories ete. complete as per direction of the Engineer-in-charge.
795Providing fitting & fixing RCPC cover etc complete as per direction of Engineer -in-charge.
796MH COVER
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail