Tender For Construction Of Mini Rural Water Supply Scheme Solar Motor Pump Complete Set In Block Dumri Panchayat Chachando Village Jobhi Svs Group Of Scheme Under Jjm D.W.S. Division, No 2 Giridih For The Year 2022-23 Svs 79, giridih-Jharkhand

Drinking Water And Sanitation Department has published Tender For Construction Of Mini Rural Water Supply Scheme Solar Motor Pump Complete Set In Block Dumri Panchayat Chachando Village Jobhi Svs Group Of Scheme Under Jjm D.W.S. Division, No 2 Giridih For The Year 2022-23 Svs 79. Submission Date for this Tender is 19-05-2023. Road Work Tenders in giridih Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

37643725
Tender For Construction Of Mini Rural Water Supply Scheme Solar Motor Pump Complete Set In Block Dumri Panchayat Chachando Village Jobhi Svs Group Of Scheme Under Jjm D.W.S. Division, No 2 Giridih For The Year 2022-23 Svs 79
Open Tender
Indian
Jharkhand
giridih
19-05-2023

Tender Details

Construction Of Mini Rural Water Supply Scheme Solar Motor Pump Complete Set In Block Dumri Panchayat Chachando Village Jobhi Svs Group Of Scheme Under Jjm D.W.S. Division, No 2 Giridih For The Year 2022-23 Svs 79 , Model-1B With Source (Drilled T/W 125/115Dia Mm, 60M Deep) , Tube Well , Drilling Portion , Construction For 115/125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125/115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , (A) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , (B) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E/I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E/I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi/Ci Cap 125 Mm Dia T/W Properly All Complete And Taking It Out As Per Specification & Direction Of E/I. (The Cap Will Be Property Of Department) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. (Medium)Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E/I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E/I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E/I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc (1:2:4) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster (1:4) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc (1:2:4) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T/Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T/W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet/Format All Complete As Per Direction Of E/I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 (Part 2) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe (Medium) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239(Part 1990). , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818/2016 Cml No.- 5543459 , Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M ,Including All Lifts, Levelling ,Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design ,Building Specification And Direction Of E/I(Vide Classification Of Soil Item -B) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials ,Labour ,Royalty And Taxes All Complete As Per Building Specification And Direction Of E/I , Back Filling , Providing Nominal Mix Pcc Of (1:2:4) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E/I , Providing Rcc M-20 In Nominal Mix Of (1:1.5:3) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E/I. , (A)Foundation For Steel Structure Staging , Footing And Vertical Pedestal Raft , Column , Tie Beam , (B)Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E/I. , (A) Foundation For Steel Structure Staging , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , (Cement+Rod) Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Galvanized Tubular Steel Structure Staging Forhdpe Water Storage Tank& Solar Panel , Providing Structural Steel Galvanisedsqure Pipe Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing ,Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge ,Including Cutting Fabricating ,Hoisting , Erecting And Fixing In Position , Making Riveted/Bolted /Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure(Plus) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns (Net Wt. Of Components To Be Galv) Preferably Tata Structural Section Etc Complete. , Hardware (L.S.) , Information Board For Iec , Providing Structural Steel Work In Trusses Other Similar Trussed Purlins And Members With Bracing Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge Including Cutting Fabricating Hoisting Erecting And Fixing In Position Making Reverted Bolted Welded Connections One Coat Of Anticorrosive Paint And Over It Two Coats Of Oil Painting Etc Complete , Installation Of 5000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 5000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 5000 Litrs Capacity Tank Up To 4.00M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 20 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil (Vide Classification Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E/I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete , Providing Pccm-200 With Nominal Mix Of (1:1.5:3) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E/I. For Construction Of Road Cutting Portion , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket (Coupler), , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe (Hdpe Pipe) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality(Screwed End). , 65 Mm Dia , 50Mm Dia , Providing And Supplying High Density Polyethylene(Hdpe )Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E./M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting/Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater/Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 50 Mm Hdpe Pipe , 65 Mm Hdpe Pipe , Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 (Part 1/2004) Isi Mark /Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E/I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I./D.I. Main Including Drilling And Taping C.I./D.I. Main All Complete As Per Specification And Direction Of E/I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E/I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E/I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 7.5. Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. (1:2:4) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. (1:4) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0) , Ii) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km/H. , Iv) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. (As Per Mnre Specification) , Vii) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii) The Suction/Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg/Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg/Sq Cm- Pe 100 Grade For 5 Hp. , Ix) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X) The Motor Pump Set Should Have A 5 Years Warranty. , Xi) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. (As Per Mnre Specification) , Xii) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv) With Third Party Inspection Before Dispatch. , Xv) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array ,The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A) Name Of The Manufacturer Or Distinctive Logo. , B) Model Number. , C) Serial Number. , Solar Submersible Motor Pump (Spv Dc Type) , I) 1 Hp (Dc Pump) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. (As Per Latest Guide Line Of Mnre) , Carrying Out Recuperation/Yield Test For Ascertaining The Discharge Of Constructed Well/ Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well/ Profile Below Normal/Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level/Subsoil Water Level In The Well / Profile As Well As Strainer/Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T/W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E/I. (As Per Model Estimate Of Solar Energy Based Mini Wss. Ts Done By Se, Ranchi Circle & Circle Gumla Dt. 21.05.2019) , Provision Of Solar Night Lamp. , Galvanised Chain-Line Mess Fencing Around Solar Panel Where Bore Well Is Away From Tower , Making 30 Cm (12) Dia Bore Up To 4M Below Ground With Hand Auger Of Approved Quality In Ordinary Soil (Vide Classification Of Soil Item-A) True To Plum And Without Eccentricity In Any Stage Of Operation And Disposal Of The Exacavated Earth Up To 50M Lead Including All Lifts All Complete As Per Approved Design And Direction Of E/I. , Providing Pcc M-150 In Nominal Mix Of (1:2:4) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including Screening Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing, Taxes And Royalty All Complete As Per Building Specification Direction Of E/I. , Labour Cost Of Fitting And Fixing Galvanised Chain-Link Mess Up Height Of 2 M Including Cost Of Staples (But Excluding The Cost Of Cement Concete Angle Iron Posts, Its Cutting And Making Holes, Nuts And Bolts) All Complete As Per Specification And Direction Of E/I. , Drilling 6Mm Dia Holes In M.S Angle Iron For Fixing Of Stables Etc. As Per Building Specification And Direction Of E/I. , Labour Cost Cutting Of M.S Angle Iron Posts To Required Length, One End Splitted As Fish Tailed In A Length Of 150Mm Complete As Per Building Sepcification And Direction Of E/I. , Supplying, Fitting And Fixing Straining Bolts With Nut Size 22Cm*10Mm Dia Tighten The Barbed Wire With Corner Post Complete As Per Building Specification And Direction Of E/I. , Supplying, Fitting And Fixing Galvanised Chain -Link Mess Having 3Mm Thick Wire Cell Type 40 X 40 Mm Fitted On M.S. Angle Frame With Two Diagonals Having 25X25x5mm Size Angle Including Cost Of Fabrication, Providing Necessary Bocking Arrangement With Haskal And Domny Duly Fixed In Angle Post, Applying A Priming Red Lead Paint Over Steel Work, Taxes Excluding The Cost Of Galvanised Chain-Link Mess All Complete. , Cost Of Galvanised Chain-Link Mess Having 3 Mm Thick Wire Cell Type 40X40 Mm Not Less Than 3.1 Kg/Sqm , Cost Of 50 X 50 X 6 Mm M.S Angle , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Annual Operation & Maintenance Cost Based On Existing D/T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year (Excluding Repair Charges) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , 18% Gst , Labour Cess

Key Value

Document Fees
INR 5000 /-
EMD
INR 35000.0 /-
Tender Value
INR 17.39 Lakhs /-

BOQ Items

Name of Work: Construction of mini rural water supply Scheme Solar motor pump complete set in Block Dumri Panchayat Chachando Village Jobhi SVS Group of Schemeunder JJM D.W.S. Division, no 2 Giridih for the Year 2022-23 (SVS-79)
Sl. No. Item Description
1MODEL-1B WITH SOURCE (Drilled T/W 125/115dia mm, 60M Deep)
2Tube Well
3Drilling Portion
4Construction for 115/125 mm dia drilled Tube-Well for drilling in all kinds of soil rock for installation of hand pump with D.T.H Rig machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant for making 125/115 mm dia boring etcand cost of transporting rig machine and other vehicle up to site workas per specification and direction of Engineer-in-charge.
5(a) Up to 30mtr. Depth bellow G.L. in Rural Areas
6(b) Beyond 30mtr.In Rural Areas
7Providing all equipments and labour for lowering 125mm dia blue UPVC Casing pipe as casing for protecting the side from falling during the process of drilling all complete job including carriage of material to work site.
8Supplying labour cement and calcium chloride or bentonite solution and equipments for Grouting to Casing Pipe all complete job including carriage of material to work site as per specification & direction of E/I
9Supplying all tools, equipments and labour and doing washing, flushing and development of drilled tube well to give clean and clear water all complete as per direction E/I.
10Supplying all materials labours and equipment including 125 mm dia GI/CI cap 125 mm dia T/W properly all complete and taking it out as per specification & direction of E/I. (the cap will be property of department)
11Civil Portion
12Supplying all tools, equipment, labours and lowering 32 mm dia G.I. (Medium)pipe in DT in 3 mtr. Length all complete job as per direction of E/I. Including carriage of materials.
13Supplying all tools, Labour for fitting and fixing deep well cylinder with necessary connecting rod all complete job as per specification & direction of E/I.
14Supplying all materials, labours for fitting and fixing of India Mark II Hand Pump with all accessories all job complete as per direction of E/I. Including carriage of materials.
15Supplying all materials, labours and equipment for constructing PCC (1:2:4) circular platform around each drilled tube well including 12mm thick cement plaster (1:4) with neat cement punning over exposed surface as per UNICEF design etc. all complete. Including carriage of materials.
16Supplying all materials labour and equipment for constructing PCC (1:2:4) drain as per UNICEF Design etc. all complete .Including carriage of materials.
17Add Extra Item for Supplying tools, labours and materials for painting, numbering and year for construction of T/Well and taking of colour photograph with two or three nearest persons including platform, drain, soak pit and also longitude & latitude, details of T/W such as total depth, casing depth, static water level, drawdown, discharge, strata chart, beneficiary population etc in separate sheet/format all complete as per direction of E/I.
18COST OF MATERIALS
19cost of standard I.S.I. mark Deep Well Hand Pump for India mark-II, I.S.I. 15500 (Part 2) / 2004 with latest revision including 12mm x 3 meter long 8 no. Connecting Rods made of bright bar electro-galvanized fitted with coupler & normal stand assembly recommended for use with cylinder assembly suitable for bore wellcasing pipe.
20Cost of 32 mm dia GI pipe (Medium) 3 Mtrs long screwed at both ends with seamless socket as per IS:1239(Part 1990).
21Cost of 125 mm dia blue UPVC Casing Pipe as per I.S.12818/2016 CML no.- 5543459
22RCC Foundation for Steel structurestaging& Solar panel
23Earth work in excavation in foundation trenches in ordinary soil and disposal of excavated earth as obtained to a distance up to 50.0m ,including all lifts, levelling ,ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design ,building specification and direction of E/I(vide classification of soil item -B)
24Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials ,labour ,royalty and taxes all complete as per building specification and direction of E/I
25Back Filling
26Providing nominal mix PCC of (1:2:4) in foundationwith approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I
27Providing RCC M-20 in nominal mix of (1:1.5:3) in columnswith approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I.
28(a)Foundation for Steel structure staging
29Footing and Vertical Pedestal Raft
30Column
31Tie Beam
32(b)Foundation for Solar panel
33Footing
34Vertical Pedestal
35Providing for steel reinforcement as per approved design and drawing excluding carriage of T.S. bar to work site cutting, bending with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/I.
36(a) Foundation for Steel structure staging
37Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
38(Cement+Rod) Lead 10 Km (avg.)
39Sand Lead 36 Km (avg.)
40Stone Chips Lead 11 Km (avg.)
41Steel Reinforcement Lead 10 Km (avg.)
42Bricks Lead 06 Km (avg.)
43Galvanized tubular Steel structure staging forHDPE water storage Tank& Solar Panel
44Providing structural steel galvanisedsqure pipe section work in trusses, other similar trussed purlins and members with all bracing ,gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge ,including cutting fabricating ,hoisting , erecting and fixing in position , making riveted/bolted /welded connections and one coat of anticorrosive paint and over it two coat of all oil painting & For Structure(PLUS) Providing and applying materials &labour for hot dip galvanizing of above structure including transportation for galvanizing minimum thickness 80microns (Net wt. of components to be Galv) preferably TATA structural section etc complete.
45HARDWARE (L.S.)
46Information board for IEC
47Providing structural steel work in trusses other similar trussed purlins and members with bracing gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge including cutting fabricating hoisting erecting and fixing in position making reverted bolted welded connections one coat of anticorrosive paint and over it two coats of oil painting etc complete
48Installation of 5000 liters Capacity Water Storage Tank
49Providing and fixing HDPE container Syntex or alike one piecemolded water tank made out of low density polythyler andbuilt corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity 5000.00 litres Capacity Water storage Tank
50Transportation Charge
51Lifting of 5000 Litrs Capacity Tank up to 4.00m height with lifting tools with rope and labour
52Making hole in Tank
53Making long screw in G.I. pipe including supplying and fitting jam nuts and extra socket etc.
54Rising and Distribution Network with House Connection up to 20 Nos. including Platform & Stand post
55Earth work in excavation in foundation trenches in hard soil (Vide Classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr. including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I.
56Dismantling plain cement concrete work including stacking serviceable materials in countable stacks within 15 M lead and disposal of unserviceable materials with all leads all complete
57Providing PCCM-200 with nominal mix of (1:1.5:3) with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of FM 2.5 to 3.0 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, sticking, curing , taxes and royalty all complete as per specification and direction of E/I. for construction of road cutting portion
58Rising Main
59Manufacture, supply and Delivery offollowing Nominal dia UPVC column pipes including PVC socket (Coupler),
6065mm dia -Density of pipe 1.38 to 1.43 Gm per Cm3 OD:74.5 to 75.2mm wall Thickness End:9mm to 10.7mm, Barrel 9mm to 10.7 mm, Length: 3Mtrs.Rising main
6150 mm dia -Density of pipe 1.38 to 1.43 Gm per Cm3 OD:87.5 to 88.2mm wall Thickness End:9 .8 mm to 11.9mm, Barrel 7.3mm to 9 mm, Length: 3Mtrs. Delivery Pipe
62Distribution
63Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074materials rates are Ex-factory excluding transportation, taxes and duties.
6463 mm HDPE Pipe
6550 mm HDPE Pipe
6632 mm HDPE Pipe
6720 mm HDPE Pipe
68Providing and fixing Gun Metal Gate valvewith C I wheel of approved quality(screwed end).
6965 mm dia
7050mm dia
71Providing and supplying High Density Polyethylene(HDPE )fittings of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074materials rates are Ex-factory excluding transportation, taxes and duties.
72Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II.
73For Rising
7450 mm HDPE Pipe
7565 mm HDPE Pipe
76Distribution
7765 mm HDPE Pipe
7850 mm HDPE Pipe
7932 mm HDPE Pipe
8020 mm HDPE Pipe
81Providing 15 mm dia. G.I. pipe Tata or equivalent make as per IS 1239 (Part 1/2004) ISI Mark /medium quality in Stand Post.
82Supplying all materials , labour and tools for fixing 15 mm dia G.I. pipes with Red lead and yarn of following nominal bore with screwed and socketed joints on wall, ceiling and floor including supplying and fitting of wall hooks or pipe clamps, wooden plugs, cutting pipes to size and threading ends if required etc. all complete as per specification and direction of Engineer-in-Charge.
83Supplying and fixing G.I. fittings of approved make all complete as per specification and direction of E/I.
84Elbow 15 mm dia.
85Reducer Socket 20x15 mm dia.
86Nipple 15 mm dia.
87Plain Socket 15 mm dia.
88Supplying and fixing G.M. ferrule of approved make in existing C.I./D.I. main Including drilling and taping C.I./D.I. main all complete as per specification and direction of E/I. 3 mm, 6 mm 10 mm dm ferrule weight not less than 425 gram.
89Providing and fixing Gun Metal full way valve of approved quality, all complete, as per specification and direction of E/I.
9065 mm dia Full way valve
9150 mm dia and weight not less than 1.5 Kg.
92Providing and fixing of male ended C.I.Body brass spindle valve and seat Bib cock of approved quality with extra socketall complete as per specification and direction of E/I.
9315 dia and weight not less than 400 Gm
94Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design.With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. Full way valve chamber
95Supplying materials , labours and equipment"s for construction of 0.90M x 0.90 M size P.C.C. (1:2:4) Rectangular Platform with stand post in house including 12 mm thick cement plaster in C.M. (1:4) with neat cement punning over exposed surfaceall complete job, as per approved design, specification and direction of E/I.
96Providing brick masonry chamber ofinner size 600 x 600 x 450 mm deep for bore well protection having 125 mm thick wall and 75 mm R.C.C cover including cement plaster of exposed surface, etc all complete job
97Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.
98Providing fitting & fixing 32 mm to 50 mm service HDPE saddleall complete job, as per approved design, specification and direction of E/I.
99Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
100Cement Lead 10 Km (avg.)
101Sand Lead 36 Km (avg.)
102Stone Chips Lead 11 Km (avg.)
103Steel ReinforCement Lead 10 Km (avg.)
104Bricks Lead 06 Km (avg.)
105Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump
106Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories.
107SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PVmodules should be minimum 200 watt peak.
108i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0)
109ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required.
110iii) The PV modules shouldbe mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h.
111iv) The module mounting structure should be hot dip galvanized according to IS 4759.
112v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be provided
113vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification)
114vii) Necessary protection such as lightening arrestor etc. should be provided to protect the controller & SPV
115viii) The suction/delivery pipe shall be UPVC / H.D.P.E. pipes of appropriate size 60m or more as required minimum pressure rating of 8kg/Sq cm- PE 100 grade for pump up to 3HP & 10 Kg/Sq cm- PE 100 grade for 5 HP.
116ix) All cable used shall be as per IS 694. Suitable size of cable shall be used in sufficient length for inter connection between the SPV array to SPV controller and SPV controller to solar power pump. Provision of cable shall be as per IS 14536.
117x) The motor pump set should have a 5 years warranty.
118xi) Control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. (As per MNRE Specification)
119xii) The SPV controller must have IP-65 protection or must be housed in cabinet having at least IP-65 protection.
120xiii) The system should be as per MNRE guide line & Eco-friendly with suitable arrangement to operate new pump manually.
121xiv) With third party inspection before dispatch.
122xv) Provision for web basedremote monitoring of the pumps to be installed must be made through the inbuilt controllers . It should be possible to ascertain the daily water output, the power generated by PV Array ,the Up and downtime of the pump during the year, number of days the pump was unused or under breakdown repairs.
123The following details should be marked indelibly on the motor pump set
124a) Name of the Manufacturer or Distinctive Logo.
125b) Model Number.
126c) Serial Number.
127Solar submersible motor pump (SPV DC Type)
128i) 1 HP (DC Pump) with 900 WP minimum watt P.V. Panel as MNRE pump head Max Shut-off head up to 120 mtrs. For higher or lower head or in between various modules output could be decided on prorates basis. (As per latest guide line of MNRE)
129Carrying out recuperation/Yield Test for ascertaining the discharge of constructed well/ excavated profile as directed by the IEC. The testout by the drawing down water from the well/ profile below normal/subsoil water level up to full depth rise is recorded the normal water level/subsoil water level in the well / profile as well as strainer/level at pump as per design of W.S. scheme shall be recorded prior to the test including cost of all materials, over Load , Labours etc. complete as directed.
130Supplying all labours, tools and equipments for dismantling of head & water tank assembly and taking out 32 mm dia old G.I. Pipe, connecting rod, cylinder assembly the dismantled components after necessary changing for making the T/W in good condition with all transportation including unused taken out materials back in store all complete job as per direction of E/I. (As per Model Estimate of Solar Energy based Mini WSS. TS done by SE, Ranchi Circle & Circle Gumla dt. 21.05.2019)
131Provision of solar night lamp.
132Galvanised Chain-line mess Fencing around Solar Panel where bore well is away from tower
133Making 30 cm (12") dia bore up to 4M below ground with hand auger of approved quality in ordinary soil (vide classification of soil item-A) true to plum and without eccentricity in any stage of operation and disposal of the exacavated earth up to 50m lead including all lifts all complete as per approved design and direction of E/I.
134Providing PCC M-150 in nominal mix of (1:2:4) in foundationwith approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5 to 3 including screening shuttering, mixing cement concrete in mixer and placing in position, vibrating, curing, taxes and royalty all complete as per building specification direction of E/I.
135Labour cost of fitting and fixing Galvanised chain-link mess up height of 2 M including cost of staples (but excluding the cost of cement concete angle iron posts, its cutting and making holes, nuts and bolts) all complete as per specification and direction of E/I.
136Drilling 6mm dia holes in M.S Angle iron for fixing of stables etc. as per building specification and direction of E/I.
137Labour cost cutting of M.S Angle iron posts to required length, one end splitted as fish tailed in a length of 150mm complete as per building sepcification and direction of E/I.
138Supplying, fitting and fixing straining bolts with nut size 22cm*10mm dia tighten the barbed wire with corner post complete as per building specification and direction of E/I.
139Supplying, fitting and fixing Galvanised chain -link mess having 3mm thick wire cell type 40 x 40 mm fitted on M.S. angle frame with two diagonals having 25x25x5mm size angle including cost of fabrication, providing necessary bocking arrangement with haskal and domny duly fixed in angle post, applying a priming red lead paint over steel work, taxes excluding the cost of Galvanised chain-link mess all complete.
140Cost of Galvanised chain-link mess having 3 mm thick wire cell type 40x40 mm not less than 3.1 kg/Sqm
141Cost of 50 x 50 x 6 mm M.S angle
142Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
143Cement Lead 10 Km (avg.)
144Sand Lead 36 Km (avg.)
145Stone Chips Lead 11 Km (avg.)
146Steel ReinforCement Lead 10 Km (avg.)
147Annual Operation & Maintenance cost based on Existing D/T Well with solarmotor pump for 5 years
148O & M Cost for 1st year (Excluding Repair Charges)
149O & M Cost for 2nd year with Annual Repair Charges
150O & M cost for 3rd Year
151O & M cost for 4th Year
152O & M cost for 5th Year
153Provision of one no SIM card & its recharging cost for RMC
15418% GST
155Labour cess
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail