Tender For Repair Maint Of Internal Electrification And Allied Essential Services Including Ceiling Fan, Exhaust Fans, Wall Mounted Fans And Lighting Protection System, Otm Accn Of Jawaharlal Nehru Road In C1 Sector And Adjoining Area Under Ge (South, ambala-Haryana

Military Engineer Services-MES has published Tender For Repair Maint Of Internal Electrification And Allied Essential Services Including Ceiling Fan, Exhaust Fans, Wall Mounted Fans And Lighting Protection System, Otm Accn Of Jawaharlal Nehru Road In C1 Sector And Adjoining Area Under Ge (South. Submission Date for this Tender is 31-05-2023. Electrification Work Tenders in ambala Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

37628574
Corrigendum : Tender For Repair Maint Of Internal Electrification And Allied Essential Services Including Ceiling Fan, Exhaust Fans, Wall Mounted Fans And Lighting Protection System, Otm Accn Of Jawaharlal Nehru Road In C1 Sector And Adjoining Area Under Ge (South
Open Tender
Indian
Haryana
ambala
31-05-2023

Tender Details

Repair Maintenance Of Internal Electrification And Allied Essential Services Including Ceiling Fan, Exhaust Fans, Wall Mounted Fans And Lighting Protection System, Otm Accn Of Jawaharlal Nehru Road In C1 Sector And Adjoining Area Under Ge ( South ) Ambala

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-May-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 31-05-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 82000.0 /-
Tender Value
INR 41 Lakhs /-

BOQ Items

NAME OF WORK : REPAIR/MAINT OF INTERNAL ELECTRIFICATION AND ALLIED ESSENTIAL SERVICES INCLUDING CEILING FAN, EXHAUST FANS, WALL MOUNTED FANS AND LIGHTING PROTECTION SYSTEM, OTM ACCN OF JAWAHARLAL NEHRU ROAD IN C-1 SECTOR AND ADJOINING AREA UNDER GE (SOUTH) AMBALA CANTT (2ND CALL).
Sl. No. Item Description
1Material and labour for taking down ceiling fan of any size/ sweep after disconnecting the wire from existing ceiling rose dismantling of blades and deposited to store for repair complete all as specified and directed.
2Supply and fixing in repair fan condencer 2.5/ 4MFD, 240 volts suitable capacity for ceiling/ exhaust fancomplete all as specified and directed.
3Supply and fixing in repair ball bearing of suitable size and capacity for ceiling/ exhaust fan complete all as specified and directed.
4Supply and fixing in repair hanging assymbly set comprising with rubber reel, mild steel clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans & down rods complete all as specified and directed.
5Material and labour for painting of ceiling fan using synthetic enamel paint in two coats over a coat of primer of any make/sweep/model etc after cleaning/washing and fill up cavities using filler including writing MES NO Black Colour complete all as specified and directed.
6Material and labour for hanging only ceiling fan any type/ sweep after repair and connecting up including provision of three core PVC insulated and unsheathed copper conductor cable of size 0.5 Sqmm from ceiling rose to connector to fan including refixing of blades complete all as specified and directed.
7Material and labour for rewinding of ceiling fan of any size with super enameled copper wire of existing gauge incuding varnishing and drying complete reassembling & testing complete of size 1200/ 1400 mm sweep complete all as specified and directed. NOTE for item No 1 to 7 : -(i) Fans to be repaired/ rewinded will be handed over to contractor at MES store yard after cutting the burnt winding in presence of Engineer-in-charge and cost of cutting of winding shall be included in the quoted rate. (ii) The cost of shifting the fan from MES store yard to contractors workshop andback shall be included in the item. (iii) Fans will be issued to the contractor in lots of 10 Nos and more for which, contractor shall ensure that minimum lot of 10 number each be returned to the department on every fifth day from the issue of fans after carried out rewinding and other repair,in failing so, the amount @ Rs. 20/- per fan per day shall be deductedfrom the contractor due till the returning of fan duly tested.
8Material and labour for taking down exhaust fan / wall mounted fan of any size/ sweep after disconnecting the wire from existing ceiling rose dismantaling of blades and deposited to store for repair all as specified and directed.
9Material and labour for rewinding of exhaust fan of any size with super enameled copper wire of existing gauge incuding varnishing and drying complete reassembling & testing complete of size 230 to 450 mm sweep complete all as specified and directed. NOTE for item No 2,3 and 8 to 11: -(i) Fans to be repaired/ rewinded will be handed over to contractor at MES store yard after cutting the burnt winding in presence of Engineer-in-charge and cost of cutting of winding shall be included in the quoted rate. (ii) The cost of shifting the fan from MES store yard to contractors workshop andback shall be included in the item. (iii) Fans will be issued to the contractor in lots of 10 Nos and more for which, contractor shall ensure that minimum lot of 10 number each be returned to the department on every fifth day from the issue of fans after carried out rewinding and other repair,in failing so, the amount @ Rs. 20/- per fan per day shall be deductedfrom the contractor due till the returning of fan duly tested.
10Supply and fixing in repair metal fan blade including fixing mountings and accessories of exhaust fan of 230 to 450 mm sweep complete all as specified and directed.
11Material and labour for fixing only exhaust fan any type/sweep after repair and connecting up including provision of cable from ceiling rose to connector to fan including refixing of blades, louvers etc all as specified and directed.
12Supply and fixing of heavy duty, plastic body exhaust fan, AC singal phase,240 volts of size 250 mm sweep with louvers connecting up including provision of fixing clamp, nut bolts and cable from ceiling rose or connector to fan,including taking down old unserviceable pastic body exhaust fan complete all as specified and directed.
13Taking down old unserviceable geyser of capacity 25 ltrs including all necessary electrical/water connection and keeping in safe custody for reuse inciuding all necessary minor repairs /servicing etcand checking serviceability of parts, necessary cleaning & reassembling the geyser, making necessaryadjustment and refixing the repaired geyser in position, connecting to existing electric & water connectionsand testing at site complete all as specified and directed. Note : The cost of minor repair including following works deemed to be included in quoted rates. (a) Inspection of geyser after opening bottom cover plate. (b) Examine any water leakage from geyser/storage tank. (c) Carry out operation of all stop cocks, pressure reducing valves,etc. to ensure free movement of the working parts. (d) Replace washers and glands to ensure smooth functioning. (e) Inspect vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items. (g) Check and correct temperature setting of thermostats. (h) Items reqd for replacement will be measured under respective item of BOQ as "Supply" only.
14Taking down old unserviceable geyser of capacity 50 ltrs including all necessary electrical/water connection and keeping in safe custody for reuse including all necessary minor repairs /servicing etcand checking serviceability of parts, necessary cleaning & reassembling the geyser, making necessaryadjustment and refixing the repaired geyser in position, connecting to existing electric & water connectionsand testing at site complete all as specified and directed. Note : The cost of minor repair including following works deemed to be included in quoted rates. (a) Inspection of geyser after opening bottom cover plate. (b) Examine any water leakage from geyser/storage tank. (c) Carry out operation of all stop cocks, pressure reducing valves,etc. to ensure free movement of the working parts. (d) Replace washers and glands to ensure smooth functioning. (e) Inspect vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items. (g) Check and correct temperature setting of thermostats. (h) Items reqd for replacement will be measured under respective item of BOQ as "Supply" only.
15Supply only heating element of capacity 2 KW of geysers of any make ISI marked complete all as specified and directed.
16Supply only heating element of capacity 1.5 KW of geyser of approved make ISI marked complete all as specified and directed.
17Supply only apparatus plate assembly with rubber gasket including nuts, bolts, washers for geysers of 50/35/25 ltrs capacity complete all as specified and directed.
18Supply only thermostat ISI marked suitable for the Geysers 25 ltrs capacity, 20 Amps, 240 Volts AC, adjustable type, 210 mm long or nearest size as per sample complete all as specified and directed.
19Supply only thermostat ISI marked suitable for the Geysers 50 ltrs capacity,20 Amps, 240 Volts AC, fixed type,300 mm long or nearest size, Set at 90+/-6 degreeC as per sample complete all as specified and directed.
20Supply only PVC connections pipe with brass hexagonal adapters both side suitable for 15mm dia pipe 60cm long for cold water as per requirement complete all as specified and directed.
21Supply only temperature resistent SS braided pipe suitable to sustaine pressure up to 8 barnot less than 60 Cm long suitable forout going / Hot water connections of Geyser with washer etc. complete as an directed.
22Supply only Non-return valve 15mm / 20mm dia of brass ISI marked as per requirement complete all as specified and directed.
23Supply onlyIndicators of Geysers of any capacity/type (Red & Green) as per requirement complete all as specified and directed.
24Supply only geyser storage inner tank made out copper sheet suitable for 25 ltrs capacitycomplete all as specified and directed.y
25Supply only geyser storage inner tank made out copper sheet suitable for 50 ltrs capacity complete all as specified and directed.
26Supply only safety valve plug made out brass metal with fusible lead, inner thread type suitable for geyser of any type/capacity complete all as specified and directed.
27Supply only PVC insulated, unsheathed cable 2.5Sqmm 3 core 1100 volt gradewith multistranded copper conductor complete all as specified and directed.
28Material and labour for attending day to day complaints of E/M nature by means of checking unserviceable Electrical fitting and fixture and emergent fault rectification in elctrical circuit inclno light , earth leakage, short cicuit, neutral breakmains /sub mains/internal circuits of existing system of main building / block ,making continious electric supply including carrying out minor repairs etc as required to make system in order / functional by replacing, copper cable , copper thimbles, glands, earthing wire complete all as specified and as directed as required at site by Engineer-in-Charge. NOTE : - (a) Items reqd for replacement such as switchs, sockets for power/light/ fan/ bell/geyser points including complete will be measured and paid under respective items of BoQ "Supply" only. (b) Contractor rep/supervisor will report to MES Service Centrealongwith qualified/Experianced electrician and helper to collect dockets between 0900 hrs to 1000 hrs on all working daysfor rectification of complaints and resubmit the dockets after completion of each job of each jobon the same day.If contractor is failed to submit the docket within 48 hoursafter issuing of dockets , the contractor i liable to pay the penalty i.e. 20.00per docket per day till the re-submission of docket. (c) Contractor will attend emergent nature of work i.e. no light, short circuit after working hours/holiday as when ordered. The rate of the is deemed to be included in above quoted rates.
29Supply only switch piano 5 Amps, flush type, single pole, one way,230 volt, AC supply, ISI Marked, complete all as specified and as directed.
30Supply onlyswitch, single pole two way 6 Amps, 230 volts AC circuit complete all as specified and as directed.
31Supply only switch piano 15 Amps flush type one way 230 Volts,50 Hz , AC supply, complete all as specified and as directed.
32Supply only bell push 5 Amps, flush type, single pole, one way, 230 volt , AC supply, complete all as specified and as directed.
33Supply only socket outlet 3 pin 6 amps, 230 volt. flush type, ISI Marked, complete all as specified and as directed.
34Supply only socket outlet 2 in 1, 6 pin 5 /16 Amp and multi pin flush type, complete all as specified and as directed.
35Supply only ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and as directed.
36Supply only fan regulator/ Dimmer electronic step type ,230 Volts, AC supply, suitable for ceiling fan any type/make/sweep, complete all as specified and as directed.
37Supply onlydoor bell electric ,ding dong /musical| type, single phase 230 volts, complete all as specified and as directed.
38Supply only lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed.
39Supply only switch modular 6 amps, one way single module with and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed.
40Supply only switch modular 16 amps, one way single module with and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed.
41Supply only socket modular 6 amps, 5 pin combined universal socket 2 module with and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed.
42Supply only socket modular 6/16 amps, 2 in 1, combined universal socket 2 module with and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed.
43Supply only fan regulator/ Dimmer step type one module / 2 module, 120W, 230 Volts, 50 Hz, AC complete with and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed.
44Supply only bell pushmodularwith and including necessary frame and cover i.e. inner and outer plate as per existing make and type complete all as specified and as directed.
45Sipply only Fan condenser 2.5 mfd complete all as specified and as directed.
46Supply only PVC insulated, unsheathed cable 4.00 Sqmm three core 1100 volt grade with multi stranded copper conductor complete all as specified and as directed.
47Supply only PVC insulated, unsheathed cable 2.5 Sqmm single core 1100 volt grade with multi stranded copper conductor complete all as specified and as directed.
48Supply only Cable PVC copper conductor flexible twin core 0.75mm complete all as specified and directed.
49Supply onlyMCB single pole, 240 volts, 50Hz , breaking capacity 10KA, "B" curve 6 to 32 Amps, ISI marked complete all as specified and as directed.
50Supply only MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, "B" curve 40 to 63 Amps, ISI marked complete all as specified and as directed.
51Supply only MCB single pole and neutral 240 volts, 16 to 32 Amps,10KA, 50 Hz,"B" Seriescomplete all as specified and as directed.
52Supply only MCB single pole and neutral 240 volts, 40 to 63 Amps,10KA, 50 Hz, "B" Seriescomplete all as specified and as directed.
53Supply only sheet metal enclosure SP with two pin and earth plug and socketincluding metal clad top with one single pole, MCB 20 Amps, "B" curve, 240 volts complete all as specified and directed.
54Dismantling/taking down carefully aluminium/ copper point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of wall, floors, ceiling etc to match with the existing surfaces with matching OBD/White wash/Distemper complete all as specified and as directed.
55Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH (FIRE Retardant Low Smoke and low Halogen), PVC insulated and unsheathed stranded cable drawn through and including non metallic, heavy duty PVC concealed conduit not less than 25 mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI flush boxes / sunken boxes made out of 1.2mm thick of any module from 2 to 18module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over sunken box for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan / bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dollywith suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed. NOTES : - (i) The quoted rates shall be deemed to be inclusive for cutting chases by chase cutter in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary accessories/fittings. (ii) Point wiring & earth wire shall be connected to each & every flush/sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
56Description all as per item No 55.00 above but for socket out let point 5 Amps on same board complete all as specified and directed.
57Description all as per item No 55.00 above but for socket out let point 5 Amps on independentboard complete all as specified and directed.
58Description all as per srl item No 55.00 above but point wiring for one socket out let 15 & 5 Amps (independent) controlled by one switchwith using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed.
59Material and labour for point wiring in existing conduit using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSHPVC insulated and unsheathed stranded cable drawn through inexisting non metallic/mettalicmedium grade concealed/Surface conduit and including replacement of its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI metal flush boxes made out of 1.2mm thick of any module from 2 to 18module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paintincluding modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbedsurfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathedFRLSH copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dollywith suitable size of lugs for one light point/ fan point/Bell Point controlled by one switch complete all as specified and as directed. NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately. 2. All chases will be cut by chase cutter only.
60Description all as per item No 59.00 above but for socket out let point 5 Amps on same board complete all as specified and directed.
61Description all as per item No 59.00 above but for socket out let point 5 Amps on independentboard complete all as specified and directed.
62Description all as per srl item No 59.00 above but point wiring for onesocket out let 15&5 Amps (independent) controlled by one switchwith using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed.
63Supply and fixing of modular switches, one way,6 amps one module, 230V, 50 Hz supply, complete all as specified and directed.
64Supply and fixing of modularswitches, oneway, 20 Amps, one module, 230 volt , AC supply, complete all as specified and directed.
65Supply and fixing of modular socket outlet 6 amps, 2/3 pin combined 2 module, 230 volt, complete all as specified and directed.
66Supply and fixing of modular socket outlet 6/20 Amps, 5 Pin, 2 module, complete all as specified and directed.
67Supply and fixing of fan regulator / Dimmer step type one module / 2 module, 100w 230 Volts, 50 Hz, AC complete all as specified and directed.
68Supply and fixing of modular switches, bell push,6 amps one module, 230V, 50 Hz supply, complete all as specified and directed.
69Supply and fixing of modular blanking plate 1 module complete all as specified and directed.
70Material and labour for concealed point wiring with 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 25 mm dia with FRLSH accessories, concealed and including provision of 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH 1100 volt grade with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally including provision of new 3 mm thick plastic laminated sheet top cover extended up to 25 mm over sunken box for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washersand making goodthe disturbed surfaces as per existing for one light/fan point/bell point controlled by one switch complete all as specified and directed. NOTES : - (i) The quoted rates shall be deemed to be inclusive for cutting chases by chase cutter in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary accessories/fittings. (ii) Point wiring & earth wire shall be connected to each & every flush/sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
71Description all as per item No 70.00 above but for socket out let point 5 Amps on same board,complete all as specified and directed.
72Description all as per item No 70.00 above but for socket out let point 5 Amps on independentboard,complete all as specified and directed.
73Description all as per item No 70.00 above but with 2.5 Sqmm cable for 3pin 15 Amps switch socket outlet (Power Point),complete all as specified and directed.
74Supply and fixing ofswitch piano 5 Amps, flush type, single pole, one way,230 volt , AC supply,ISI Marked, complete all as specified and directed.
75Supply and fixing ofswitch piano 15 Amps flush type one way 230 Volts,50 Hz , AC supply, ISI Marked, complete all as specified and directed.
76Supply and fixing ofbell push 5 Amps, flush type, single pole, one way, 230 volt , AC supply, ISI Marked, complete all as specified and directed.
77Supply and fixing ofsocket outlet 3 pin 6 amps, 230 volt. flush type, ISI Marked, complete all as speciied and directed.
78Supply and fixing ofsocket outlet 2 in 1, 6 pin 5 /16 Amp and multi pin flush type, complete all as specified and directed.
79Supply and fixing ofceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified.
80Supply and fixing offan regulator/ Dimmer electronic step type ,230 Volts, AC supply, suitable for ceiling fan any type/make/sweep, complete all as specified and directed.
81Supply and fixing of door bell electric ,ding dong /musical type, single phase 230 volts, ISI marked complete all as specified.
82Supply and fixing oflamp holder, PVC/polycarbonate type with back plate suitable for batten fittings,complete all as specified.
83Supply and fixing in repair of sheet metal enclosure SP with two pin and earth plug and socket inclduing metal clad top with one single pole MCB 20 Amp, "B" Curve, 240 Volts complete all as specified and directed.
84Supply and fixing of LED light fitting 1x20W, 220V, AC with aluminium housing with batten type with driver, holder including 20W LED tube light for connecting up with three core flexiable copper conductor cable of suitablae size from celing rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
85Supply and fixing of channel for fixing of LED tube rod of CRCA body suitable for 18/20 watt LED tube, high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. (Tube rod shall be measured and paid for separately). Note: - Channelmust be get approved from Engineer in charge to check fesibilty i.e. one end contact or two end contact.
86Supply and fixing of 18 Watt / 20 Watt LED tube light two end contact, fitting should have lumen output more than 100 lumens per watt, environment friendly, high efficient, T8 with aluminium extrusion heat sink for optimum performance with high luminous efficiency and easy and taking down existing tube light and removal complete all as specified and directed. NOTE: - Tube rod must be get approved from Engineer in charge to check fesibilty i.e. one end contact or two end contact for fixing in existing LED fittings.
87Supply and fixing of box type batten withsurface mounted LED tube light fitting with high efficient diffuser mirror light, aluminium housingin CRCA body suitable and including 10 watt LED tube rod high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
88Supply and fixing of LED bulk head light fitting, 10 watt, energy efficient withlamp 10 watt with provision of 2/3 core PVC copper conductor cable 0.5 Sqmm size from ceiling rose to light fitting completeincluding disconnecting and taking down old existing light fitting of any descriptioncomplete all as specified and directed.
89Supply and fixing in repair bracket for security light made up of 25/40 mm dia, 0.60 metre long GI pipe,light grade, bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete all as specified and directed.
90Supply and fix LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDshaving optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down oldunserviceable security light fitting of any description and in any positioncomplete all as specified and directed.
91Supply and fixLED security light luminaire 45 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down oldunserviceable security light fitting of any description and in any position complete all as specified and directed.
92Supply and fixinverter LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDshaving optical grade polycarbonate lens with 4 hours battery back up all accessories internally pre wired and including connecting up with two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down oldunserviceable security light fitting of any description and in any position complete all as specified and directed.
93Supply and fixing of LED security light luminaire 80 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs not less than 2 W each hand having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down oldunserviceable security light fitting of any description and in any position complete all as specified and directed.
94Supply and fixing of post top lantern LED 30 Watt cast aluminium spigot, with high effieient LED light, with poly carbonate diffuser, complete with high efficient LED lamp 30 W and accessoriesinternally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable including disconnecting and taking down existing light fitting and removal complete all as specified and directed. NOTE: - LED (Cool white or warm white) must be get approved from Engineer-in-Charge.
95Disconnecting and taking down old existing Bollard light fitting of any description and in any position and supply and fixingLED bollard light fittings with aluminium pipe housing swith glare fee PMMA diffuser , IP 65 protection ofheight not less than 600 mm with and including 10 watt LED including base frame made up of sheet metal and connecting up with three core 1.5 sqmm flexible copper conductor cable including necessary excavation, removal and PCC 1:3:6 work as directed etc complete all as specified and directed. NOTE : LED (Cool white or warm white) must get approved from Engineer-in-Charge.
96Supply and fixing of LED flood light highly efficient integral type, made of pressure die cast aluminium housing with 10 KV SPD, lens & toughened glass IP 66, energy efficient provided withincluding LED50 watt withprovision of 2/3 core PVC copper conductor cable of suitable size size to light fitting and completeincluding disconnecting and taking down existing light fitting and removal complete all as specified and directed.
97Supply and fixing recess/ surface mounted LED flat panel 2" x 2" with high efficient LEDs and glare free full decorative light fitting, 36 watt, energy efficient provided withincluding LED36 watt withprovision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting and completeincluding disconnecting and taking down existing light fitting and removal complete all as specified and directed.
98Supply and fixing of Inverter LED tube light fitting 1x20 Watt with minimum 04 hours battery back integrated aluminium batten with diffuser and including 20 Watt LED hight efficient, AC 220-240 V, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connectorof the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
99Supply and fixing recess mounted LED flat panel 2" x 4" with high efficient LEDs and glare free full decorative light fitting, 72 watt, energy efficient provided withincluding LED72 watt withprovision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting and completeincluding disconnecting and taking down existing light fitting and removal complete all as specified and directed.
100Material and labour for concealed sub main wiring with two single core FRLSH PVCinsulatedunsheathed copper conductor cable 2.5 sqmm drawnin and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories onwall or ceiling withone additional PVC insulated , strandedcopper conductor FRLSH of 2.5 sqmm, green colourfor earthcontinuity conductor including taking down old unserviceable sub main wiringand making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run ofconduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chasesin wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
101Material and labour for concealed sub main wiring with two single core FRLSH PVCinsulatedunsheathed copper conductor cable 4.0 sqmm drawnin and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories onwall or ceiling withone additional PVC insulated , strandedcopper conductor FRLSH of 4.0 sqmm, green colourfor earthcontinuity conductor including taking down old unserviceable sub main wiringand making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run ofconduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chasesin wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
102Material and labour for concealed sub main wiring with two single core FRLSH PVCinsulatedunsheathed copper conductor cable 6.0 sqmm drawnin and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories onwall or ceiling withone additional PVC insulated , strandedcopper conductor FRLSH of 6.0 sqmm, green colourfor earthcontinuity conductor including taking down old unserviceable sub main wiringand making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run ofconduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chasesin wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
103Material and labour for earthing and material & labour for earthing with galvanised steel earth plate electrode 60cmx 60cm x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer ofcharcoal dust and common salt filling in alternate layers and electrode connections by usinggalvanised iron wire 4mmas earthing lead(upto terminal point) by means ofbolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 15 mm diaGI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh, 50 mm thick precast RCC 1:2:4 type B1using 20 mm graded stone aggregate , reinforced with 8 mm dia dedormed /TMT bars 3 nos both way 12 mm dia round bar handle and PCC chamber pit with PCC (1:3:6)type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type ofsoil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 ofSSR 2009 (Part-I) complete all as specified and as directed. Note :- (i) Earth lead wire and its protection pipe upto and including 7.50 mtr only from top of earth electrode are included under this item. (ii)On testing if the earth resistance is not obtained within permissible limit, earthing will be re-done at NO extra cost ,till the desired earth resistance is obtained. (iii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted.
104Supply and fixing of sheet metal enclosures vertical distribution board VTPN, (MCCB DB) 4 ways, double door, 415 volts with 200 amps rated bus bar IP-43 protection, with shrouded neutral bar and insulated bus bar and earth link, with and includingMCCB 4 pole thermal release type, 125 Amps, 25 KAas incomer and MCBsas out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs/thimbles/glands and making good the disturbed surface matching with existing surface including taking down existing unserviciable MCCB/DBs including MCBs complete all as specified and directed.
105Supply and fixing of sheet metal enclosures vertical distribution board VTPN, (MCCB DB) 4 ways, double door, 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and includingMCCB 4 pole thermal release type, 100 Amps, 16 KAas incomer and MCBsas out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs/thimbles/glands and making good the disturbed surface matching with existing surface including taking down existing unserviciable MCCB/DBs including MCBs complete all as specified and directed.
106Supply, installation, testingofSPN distibution board 8 way,double door , IP 43, as per IS 8623including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles/glands including taking down existing unserviciable MCB/DBs including MCBs complete all as specified and directed.
107Supply and fixing in repair of sheet steel enclosure with separate busbar chamber for cable terminationwith and including MCCB four pole, 240 volts, 50Hz , breaking capacity 25KA, 125 Amps, thermal release type, complete all as specified and directed.
108Supply and fixing of MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, "B" curve 6 to 32 Amps, including connection with suitable size copper lugs complete all as specified and directed.
109Supply and fixing of MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, "B" curve 40 to 63 Amps, including connection with suitable size copper lugs complete all as specified and directed.
110Supply and fixing of MCB single pole and neutral, 240 volts, 50Hz , breaking capacity 10KA, "B" curve 16 to 32 Amps, including connection with suitable size copper lugs complete all as specified and directed.
111Supply and fixing of MCB single pole and neutral, 240 volts, 50Hz , breaking capacity 10KA, "B" curve 40 to 63 Amps, including connection with suitable size copper lugs complete all as specified and directed.
112Supply and fixing in repair of MCB four pole, 240 volts, 50Hz , breaking capacity 16KA, 100 Amps, B curve, including connection with suitable size copper lugs complete all as specified and directed.
113Supply and fixing in repair of MCB four pole, 240 volts, 50Hz , breaking capacity 10KA, 63 Amps, B curve, including connection with suitable size copper lugs complete all as specified and directed.
114Supply and fixing in repair of MCCB four pole 415 volts, 125 Amps,25KA, 50 Hz, thermal adjustable typecomplete all as specified and as directed.
115Supply and fixing in repair ofMCCB four pole 415 volts, 100 Amps,16KA, 50 Hz thermal adjustable type complete all as specified and as directed.
116Supply and fixing in repair ofPCB unit of suitable size for BLDC Ceiling fan of 1200mm sweep, single phase, 240 V complete all as specified and directed.
117Supply and fixing in repair of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable circulat of size 10Sqmm including all incoming and outgoing connection with proper size of thimble complete all as specified and directed.
118Supply and fixing in repair of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable circulat of size 16Sqmm including all incoming and outgoing connection with proper size of thimble complete all as specified and directed.
119Material and labour for taking down existing light fitting i.e. tube light, surface ceiling light, security light, flame proof light etc any type / size/ make / capacity and refix the same after minor repair/ cleaning including replacement of connection wire with 0.75sqmm copper wire twin core for connection from ceiling rose to light fitting all as specified and directed.
120NOTE:- Amount of credit ofRs. 97,559.00 for retrieved materials is mentioned in Schedule of Credit Page No 19 & 20 of tender documents in pdf form which will be deducted offline while acceptance of tender.