Tender For Biennial Civil Maintenance And Housekeeping Work For 1X660mw Unit Ofharduaganj Thermal Power Project, Kasimpur, Aligarh”., Aligarh-Uttar Pradesh

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited-UPRVUNL has published Tender For Biennial Civil Maintenance And Housekeeping Work For 1X660mw Unit Ofharduaganj Thermal Power Project, Kasimpur, Aligarh”.. Submission Date for this Tender is 13-06-2023. Civil Work Tenders in Aligarh Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

37612999
Corrigendum : Tender For Biennial Civil Maintenance And Housekeeping Work For 1X660mw Unit Ofharduaganj Thermal Power Project, Kasimpur, Aligarh”.
Open Tender
Indian
Uttar Pradesh
Aligarh
13-06-2023

Tender Details

Tender For Biennial Civil Maintenance And Housekeeping Work For 1X660mw Unit Ofharduaganj Thermal Power Project, Kasimpur, Aligarh”.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 31-May-2023 Date Extension1 Date 13-06-2023

Key Value

Document Fees
INR 11800 /-
EMD
INR 700000.0 /-
Tender Value
INR 3.48 Crore /-

BOQ Items

Name of Work: Biennial Civil Maintenance and Housekeeping work for 1x660MW Unit ofHarduaganj Thermal Power Project, Kasimpur, Aligarh”.
Sl. No. Item Description
1Water Supply and Sanitation
2Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of430x260x350 mm or 340x410x265 mm sizes respectively. (DSR No. 17.23)
3Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.(Granite Stone of approved shade ) (DSR No. 8.10.2)
4Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approve with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (DSR No. 17.31)
5Providing and fixing soil, waste and vent pipes:17.35.1 100 mm dia 17.35.1.1 Sand cast iron S&S pipe as per IS: 1729 17.35.2 75 mm diameter 17.35.2.1 Sand cast iron S&S pipe as per IS: 1729 (DSR No. 17.35.2.1)
6Providing and fixing 100 mm sand cast Iron grating for gully trap. (DSR No. 17.29)
7Providing and fixing plain bend of required degree. 17.39.1100 mm dia 17.39.1.1 Sand cast iron S&S as per IS - 1729 (DSR No. 17.39.1.1)
8Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :(610x510 mm bowl depth 200 mm ) (DSR No. 17.10.2.1)
9Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. 17.69.1 Waste coupling 31 mm dia of 79 mm length and 62 mm breadth weighing not less than 45 gms (DSR No. 17.69.1)
10Waste coupling 38 mm dia of 83 mm length and 77 mm breadth, weighing not less than 60 gms (DSR No. 17.69.2)
11Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: 17.60.2100 mm inlet and 75 mm outlet 17.60.2.2 Sand Cast Iron S&S as per IS- 1729 (DSR No. 17.60.2.2)
12Providing and fixing door piece, insertion rubber washer 3 mm thick, bolts & nuts complete: 100 mm 17.55.1.2 Sand cast iron S&S as per IS - 3989 (DSR No. 17.55.1)
13Providing and fixing unplasticised PVC connection pipe with brass unions: 18.21.2 45 cmlength18.21.2.1 15 mm nominal bore (DSR No. 18.21.2.1)
14Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 :18.72.2 150 mm dia Ductile Iron Class K-7 pipes (DSR No. 18.72.2)
15Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required.15 mm nominal bore (DSR No. 18.47.1)
16Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required.20 mm nominal bore (DSR No. 18.47.2)
17Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required.25 mm nominal bore (DSR No. 18.47.3)
18Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required.32 mm nominal bore (DSR No. 18.47.4)
19Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required.40 mm nominal bore (DSR No. 18.47.5)
20Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required.50 mm nominal bore each 1118.30 (DSR No. 18.47.6)
2115 mm nominal bore, 80 mm long, weighing not less than 46 gms (DSR No. 18.57.2)
22Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (110 mm diameter)(DSR No. 12.41.2)
23Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm nominal inner dia Pipes) (DSR No. 18.9.10)
24Cleaning of C.I down pipe from roof to bottom including all labour T&P complete dismantling and refixing complete(NSI)
25Searching, sorting out and attending leakage and choking faults in external or internal running water mains, sever lines of different diameters at all elevations from 0 to 18 mm level including all materials as G.I bend , elbow, tee, socket, nipple etc. and supply of all labour, T&P such as thread cutting, dye, bunch voce, hacksaws pipe wrench etc. (NSI)
26Rewinding of 5.00 to 7.5 H.P capacity three phase vertical or horizontal motor for pump of tubewell with class B insulated copper wire of I.S.I approved quality including painting varnishing etc. complete as per direction of E/I(NSI)
27Repairing servicing of fully automatic three phase starter by replacing thermal relay including testing of load replacement of connecting wire required etc. (NSI)
28Attending complaints such as replacement of taps, washers, spindle for pillar cocks etc. by providing plumper at the complaints office including all labour T&P threads, safeda etc. required for proper completion of the work. (NSI)
29P/F G.I. Pipes complete with G.I. Fittings & Clamps including cutting & making good the walls etc. (Internal work) 15mm dia Nominal bore.) (DSR No. 18.10.1)
30P/F G.I. Pipes complete with G.I. Fittings & Clamps including cutting & making good the walls etc. (Internal work) 20mm dia Nominal bore.) (DSR No. 18.10.2)
31Providing and fixing G.I. pipe complete with G.I. fittings including trenching and refilling etc. for external work 15 mm dia nominal bore(DSR No. 18.12.1)
32Providing and fixing G.I. pipe complete with G.I. fittings including trenching and refilling etc. for external work 20 mm dia nominal bore(DSR No. 18.12.2)
33Providing and fixing G.I. pipe complete with G.I. fittings including trenching and refilling etc. for external work 25 mm dia nominal bore(DSR No. 18.12.3)
34Providing and fixing G.I. pipe complete with G.I. fittings including trenching and refilling etc. for external work 32 mm dia nominal bore (DSR No. 18.12.4)
35Providing and fixing G.I. pipe complete with G.I. fittings including trenching and refilling etc. for external work 40 mm dia nominal bore(DSR No. 18.12.5)
36Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 50 mm dia nominal bore (DSR No. 18.12.6)
37Making connection of 25 to 40mm nominal bore G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete.(DSR No. 18.13.1)
38P/F gun metal gate valve with C.I. wheel of approved quality (screwed end) 25 mm dianominal bore (DSR No. 18.17.1)
39P/F gun metal gate valve with C.I. wheel of approved quality (screwed end) 32 mm dianominal bore (DSR No. 18.17.2)
40P/F gun metal gate valve with C.I. wheel of approved quality (screwed end) 40 mm dianominal bore (DSR No. 18.17.3)
41P/F gun metal gate valve with C.I. wheel of approved quality (screwed end) 50 mm dianominal bore (DSR No. 18.17.4)
42P/F gun metal gate valve with C.I. wheel of approved quality (screwed end) 65 mm dianominal bore (DSR No. 18.17.5)
43Dismantling of 100mm dia old SW Pipe line including braking of joint & bed concrete, stacking of useful material near the site within 50Mtr. lead & disposal of unserviceable material in nearest dumping place. (DSR No. 19.5.1)
44P/F white vitreous china flat back wash basin size630x450 mm including making all connection but excluding cost of fitting. (DSR No. 17.25.2)
45P/F 10 liter capacity- white PVC low level flushing cistern with manually controlled device (handle lever) conforming to IS: 7231 with all fittings and fixtures complete. (DSR No. 17.18.1)
46P/F 15mm nominalball valve (brass)of approved quality, high or low pressure, with plastic floats complete(DSR No. 18.18.1)
47P/F Orissa pattern W.C. pan of size 580X440mm white vitreous china water closet squatting pan.(DSR No. 17.13.2)
48Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (W.C. pan with ISI marked black solid plastic seat and lid.) (DSR No. 17.3.2)
49P/F P.V.C. waste pipe 32mm dia for sink or wash basin including P.V.C. waste fittings complete including west fittings complete.(DSR No. 17.28.1.1)
50P/F on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion (i) single socketed pipes 110mm diameter(DSR No. 12.41.2)
51P/F MS holder bat clamps of appd. Design to CI/SCI/AC rain water pipes embedded in and including cement concrete Blocks 10X10X10mm of 1:2:4 mix (1cement 2 coarse sand and 4 stone ballast) including cost of cutting holes and making good the wall complete. For 110 dia pipes.(DSR No. 17.37.1)
52Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms each 555.35 (DSR No. 17.73.1)
53Providing and fixing toilet paper holder : C.P. brass each 583.75 (DSR No. 17.34.1)
54Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.(DSR No. 17.71)
55P/F PTMT pillar cock of approved quality & colour.15mm nominal bore, 86 mm long, weighing not less than 88gms. (DSR No. 18.54.1)
56P/F PTMT pillar cock of approved quality & colour.15mm nominal bore, 107mm long, weighing not less than 110gms. (DSR No. 18.56.1)
57Cleaning of Septic Tank chambers & disposal of malwa outside the boundary wall of colony/ power house. (NSR)
58Cleaning ofInspection Chamber & disposal of malwa outside the boundary wall of colony/ power house. (NSR)
59P/F 30 cm. length/ 15mm nominal size uplasticised PVC connection pipe with brass unions(DSR No. 18.21.1.1)
60P/F 100mm sand cast iron grating for gully trap. (DSR No. 17.29)
61M.S angle 32X32X3mm brackets for washbasin & cistern of required length.(NSR)
62Providing and placing on terrace (at all floor levels) capacity polyethylene 500/1000litter water storage tank ISI: 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank(DSR No. 18.48)
63P/F PTMT stop cock of approved quality & colour 15mm nominal bore, 86mm long weighing not less than 88gms. (DSR No. 18.55.1)
64-do- but CI bib cock. (DSR No. 18.54.1)
65P/F brass bib cock 15mm nominal size of approved quality. (DSR No 18.15.1)
66-do- but stop cock(DSR No. 18.16.1)
67P/F 15mmnominal bore C.P. Brass bib cock of approved quality conforming to IS:8931 (DSR No. 18.49.1)
68P/F C.P. brass stop cock ( concealed) of standard design and approved of 15mm nominal bore(DSR No. 18.52.1)
69P/F battery for sensor of automatic pillar cock (NSR)
70Misc Civil Work
71Earth work in excavation over areas exceeding 30 cm. In depth 1.5M in width as well as 10 Sqm On plan) including disposal of excavated earth, lead upto 50M and lift upto 1.5M disposed earth to be leveled and neatly dressed. All kind of soil. (DSR No. 2.6.1)
72P/L in position cement concrete 1:4:8 ( 1 cement : 4 coarse sand 8 graded stone aggregate 40mm nominal size) excluding the cost of centering and shuttering- all work up to plinth level. (DSR No. 4.1.8)
73R.C.C. work in beams, suspended floors, roofs having bands, plain window sills, staircase and spiral staircases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) (DSR No. 5.3)
74Steel reinforcementfor RCCwork incl. straighteningcutting bending binding placing in position all complete upto plinth level with TMT bars (DSR No. 5.22.6)
7512mm thick cement plaster of mix 1:6 (1cement : 6 coarse sand ) (DSR No. 13.4.2)
76Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-all work up to plinth level 1:2:4 ( 1 cement 2 coarse sand 4 graded stone aggregate 20mm nominal size)(DSR No. 4.1.3)
7740mm thick with 20 mm nominal size stone aggregate cement concrete flooring in 1:2:4 (1cement: 2 Coarse Chambal red Sand : 4 graded stone aggregate ) finished with floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.(DSR No. 11.3.1)
78Centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns etc. for mass concrete. (DSR No. 5.9.1)
79Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)(DSR No. 6.1.2)
80Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR No. 6.4.2)
81Cleaning of old bricks recovered from demolition of old brickwork by removing mortar, lumps and any other loose material from bricks and makinggood for use in masonry. (NSI)
82Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) ( Old brick provided by department) (NSR)
83Tractor with trolley for transportation of Brick from 1x660 M.W. HTPP Kasimpur and other misc. work in plant(DSR No. 0039)
8412 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) (DSR No. 13.4.2)
85Demolishing brick work in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 Mtr. Lead (DSR No. 15.7.4)
86Dismantling of old plaster skirting racking out joint and cleaning the surface for plaster incl. disposal of rubbish to the dumping ground within 50 mtrs lead. (DSR No. 15.56)
87Demolishing RCC work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 mit lead as per direction of engineer-in-charge (DSR No. 15.3)
88Carriage of earth and rubbish and concrete waste by mechanical transport including loading, unloading and stacking upto lead 3 km (DSR No. 1.1.2)
89P/F 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by E/I, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement:3 coarse sand) and jointing with grey cement slurry @3.3 kg per sqm, incl. pointing in white cement mixed with pigment of matching shade complete. (DSR No 11.36)
90P/F ceramic glazed floor tiles of size 300X300 mm (thickness to be specified by manufacturer) of 1st quality conforming to IS: 15622, of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) incl. pointing the joints with white cement and matching pigment etc. complete. (DSR No. 11.37)
91Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption"s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete of size of tile 600X600 mm (DSR No. 11.41.2)
92Front end loader 1 cum bucket capacity (incl POL) (DSR No. 0052)
93Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR No. 10.1)
94Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Steel provided by department (NSR)
95Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. (DSR No. 22.22A)
9622.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) (DSR No. 22.5)
97Providing and laying GP 2 grouting (NSI)
98Epoxy Resin –C/257 (NSI)
99Hardner-xy54 (NSI)
100Sand Dust (NSI)
101Making 25 mm. dia bore of 200 mm depth with hydraulic hammer and grouting 20 mm bolt with chemical HIT RE500 of hilti brand (bolts shall be provided by UPRVUNL)(NSI)
102P/L four course water proofing treatment with bitumen felt (hessian base)over roofs consisting of 1’and 3’ courses of blown bitumen 85/25 or 90/15 applied hot @ 1.45 kg per M2 of area for each course, second course of roof felt type 3 grade-I and fourth and final course of stone grit 6 mm and down size gravel spread at 6 m3 dia. Per m2 incl. Preparation of surface. (DSR No. 22.8.1)
103P/L four course water proofing treatment with bitumen felt (hessian base)over roofs consisting of 1’and 3’ courses of blown bitumen 85/25 or 90/15 applied hot @ 1.45 kg per M2 of area for each course, second course of roof felt type 3 grade-I and fourth and final course of stone grit 6 mm and down size gravel spread at 6 m3 dia. Per m2 incl. Preparation of surface. Bitumen provideed by department to IS: 1322 (NSR based on 22.8.1)
104For sealing cracks and faulty construction joints, routed out/making U-shape groove size 25x25mm and then primed the area with integral crystalline slurry @0.05kg/ running metre and while the surface is tacky filled the groove upto surface with crystalline mortar @1.50kg/ running metre. Once crystalline mortar is touch dry then finally applied two coats of integral crystalline slurry @0.05kg/running metre per coa.(22.25.1 )
105Providing and inserting 12mm dia galvanised steel injection nipple in honey comb area and along crack line including drilling of holes of required diametre (20mm to 30mm) up to depth from 30mm to 80mm at required spacing and making the hole & crack dust free by blowing. compressed air, sealing the distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of Engineer-In-Charge
106Making 30 mm. dia bore of 200 mm depth with hydraulic hammer and grouting 24 mm bolt with chemical HIT RE500 of hilti brand (bolts shall be provided by UPRVUNL) (NSI)
107P/F ISI marked30 mm thick door shutters conforming to IS: 2202 non-decorative type including ISI marked stainless steel butt hinges with necessary screws, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands(DSR No. 9.21.2)
108Renewing glass panes, with putty and nails, wherever necessary incl. racking out old putty. Float glass panes of thickness 4.0 mm (DSR No. 14.5.1)
109Re-fixing old glass panes with putty and nails (DSR No 14.10)
110Fencing with angle iron/ boiler tube post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire 9.38 Kg. per 100m (minimum) between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete (cost of posts, struts, earth work and concrete work to be paid for separately) :- payment to be made per meter cost of total length of barbed wire used.With G.I. barbed wire (DSR No. 16.18.1)
111Welding by gas or electric plant including transportation of plant at site etc. complete.(DSR No. 10.22)
112Fixing of door chaukhat in existing opening including embedding chaukhats in floor or walls or cutting masonry for hold fast in C.C. block with cement concrete In 1:3:6 (1 cement, 3 coarse sand, 6 graded stone Aggregate 20mm nominal size), painting 2 coats of coal tar 2 sides of chaukhat& making good the damages in walls or floor as required complete. (DSR No. 14.2.1)
113Same as above but window chaukhat (DSR No.14.2.2)
114P/F hard drawn steel wire fabric 75x25mm mesh of weight not 7.75 Kg. per Sqm to window frames etc including 62x19 mm beading of IInd class Teak wood. (DSR No. 9.50)
115P/F IS3564 marked aluminum die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete. (DSR No. 9.83)
116P/F fly proof galvanized M.S. wire gauge to windows and clerestory windiws using wire gauge with averagewidth of aperture 1.4mm in both direction with wire of dia .63mm all complete. With 12mm M.S.U beading. (DSR No. 9.51.2)
117P/F ISI marked oxidized M.S.slidingdoorboltswithnutsandscrewsetc. complete : 300x16 mm (DSR No. 9.62.1)
118P/F ISI marked oxidized M.S.slidingdoorboltswithnutsandscrewsetc. complete : 250x16 mm (DSR No. 9.62.2)
119Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (DSR No. 9.82)
120Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :250x10 mm (DSR No. 9.63.1)
121Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :200x10 mm (DSR No. 9.63.2)
122Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :150x10 mm (DSR No. 9.63.3)
123Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :100x10 mm (DSR No. 9.63.4)
124P/F ISI marked oxidized M.S. handlesconformingto IS:4992withnecessary screws etc. complete :125 mm (DSR No. 9.66.1)
125P/F ISI marked oxidized M.S. handlesconformingto IS:4992withnecessary screws etc. complete :100 mm (DSR No. 9.66.2)
126P/F ISI marked oxidized M.S. handlesconformingto IS:4992withnecessary screws etc. complete :75 mm (DSR No. 9.66.3)
127Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6mmangle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces. (DSR No. 10.5.1)
128Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing and paneling to be paid for separately) : For fixed portion Anodized aluminium (anodized transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade AC 15) (DSR No. 21.1.1.1)
129Providing and fixing 12mm thick pre-laminatedparticle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side.(DSR No. 21.2.1)
130P/F double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315 having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors , embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece MS sheet outer box with slide plate etc. complete as per direction of E/IWith stainless steel cover plate minimum 1.25 mm thickness (DSR No. 21.4.1)
131Filling the gap in between aluminium frame and adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of E/I complete upto 5 mm depth and 5 mm width (DSR No. 21.8.1)
132ProvidingcarpenterIInd class. (DSR No. 112)
133P/F 30 mm with ISI marked stainless steel butt hinges with necessary screws, flush door shutters conforming to IS: 2202 (Part-I) decorative type core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.(DSR No. 9.20.2)
134Repairing & Fixing Pre-Painted Coil coated steel false ceiling system, tile typesquare pattern panels 600x600 m.m. size at all level, for all kind of work, consisting of 0.5 mm tick galvanized to grade 180 as per IS:277, along with galvanized. SupportingSteel member exposed faces of galvanized Member to be Supporting with regular modified polyester coating/superpolyester coating minimum 20 DFTto form panels of specified size for tile type panels and toll formed stove enameled 0.6 mm thick steel carrier, for Fixing of lineal type panels by clip on arrangement, suspended form RCC slab/structural steel or catwalk way steel channel grid above with 4 mm (minimum) galvanized wires (rods),with special height adjustment clips, providing angle section of minimum 25 mm leg with along the perimeter of ceiling, including all labor, material, supporting grid system (members minimum 0.8mm thick and galvanized @ 150g/sq.M.as per IS:277) equipment, handling, transportation, workmanship, anchor fasteners for making suspension arrangement from RCC. Including all labour, material T&P etc. Complete but excluding cost of false ceiling.
135Attending complaint regarding aluminium work of door/window/partition including all labour, material T&P, Fitter and helper (NSR)
136P/F 15 mm thick tegular edged light weight calcium silicate false ceiling tiles. false ceiling tiles of Size 595x595mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991 (NSR based on 26.22.1)
137P/F 15 mm thick tegular edged light weight calcium silicate false ceiling tiles. false ceiling tiles of Size 595x595mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991 (NSR based on 26.22.1)
138Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like.
139Laying coal boulder/ grit/ brick bats for filling Road’s pit etc. coal boulder/ brick bats available at P.H. coal area including ramming blinding with earth etc. complete for proper completion of work. (DSR No 16.5.1)
140Providing non-asbestos high impact Polypropylene reinforced cement 6mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete excluding the cost of purlins, rafters and trusses: corrugated sheets and including cutting to size and shape wherever required. (DSR No. 12.8)
141Finishing/Painting Work
142Providing and applying white cement based putty of 1mm thickness over plastered wall surface to prepare the surface even and smooth complete (DSR No. 13.8)
143Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade :One or more coats on old work (DSR No. 13.98.1)
144Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture (DSR No. 13.48.3)
145Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture (DSR No. 13.48.2)
146Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (DSR No. 13.91)
147Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR No. 13.80)
148Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :Old work (one or more coats) .(DSR No. 13.90.1)
149Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) (DSR No. 13.44.1)
150Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work (DSR No. 13.42.1)
151Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : Old work (one or more coats) (DSR No. 14.45.1)
152Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer’s specificationOne or more coats on old work (DSR No. 13.108)
153Painting with acid proof paint of approved brand and manufacture of required colour to give an even shadeOne or more coats on old work (DSR No. 13.101.1)
154Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade( Two or more coats on new work) (DSR No. 13.64.1)
155Finishing walls with water proofing cement paint of required shade.Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat. (DSR No. 13.109.1)
156Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution.(DSR No. 13.53.1)
157White washing with lime to give an even shade: New work (three or more coats)(DSR No. 13.37.1)
158Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work. (DSR No. 13.99.1)
159Colour washing such as green, blue or buff to give an even shade : New work (two or more coats) with a base coat of white washing with lime(DSR No. 13.39.1)
160Lettering with black Japan or approved paint of approved band and manufacture. (DSR No. 13.71)
161JUNGLECLEANING
162Clearing jungle including uprooting of rank vegetation, grass brush wood, trees and sapling of girth up to 30cm measured at a height of 1 mtr. above ground level and removal of rubbish up to a distance of 50mtr outside the periphery of the area cleared. (DSR No. 2.31)
163Cleaning grass and removal of the rubbish up to a distance of 50M outside the periphery of the area cleared .(DSR No. 2.32)
164Surface dressing of the ground including removing vegetationand inequalities not exceeds15cm deep and disposalof rubbish lead up to 50m and lift up to1.5mall kind of soil(DSR No 2.28.1)
165Felling trees of girth measured at a height of 1 M. above ground level including cutting of trunks and branches and stacking serviceable material and disposal of unserviceable material beyond 30 Cm. girth . (DSR No. 2.33.1)
166HOUSEKEEPING
167Cleaning of roof of building of various heightfrom 4 to 36 M including removing of grass, industrial waste , garbage such as Ash . Coal dust, building waste etc. maximum thickness 10 cm including sweeping and lifting and cartage of the same from roof to hopper by manual labour and dropping the same up By hopper including all labour, T&P etc.
168Sweeping,cleaning ,mopping & dusting,cleaning of spider net, glass panes of doors and windows, wet wash with phenyle or approved germicide daily etc. at all floors of Administrative building (G+2) with plinth area 1100 sqm. including all manpower, T&P etc for proper completion ofwork.
169Sweeping cleaning & mopping all floors and also including wet wash with phenyle or approved germicide daily at all floors of servicebuilding includingG+3 with plinth area 1008 sqm.Including all T&P etc for proper completion ofwork.
170Sweeping,cleaning ,mopping & dusting,cleaning of spider net, glass panes of doors and windows, wet wash with phenyle or approved germicide daily etc. at all floors of switch yard cotrol building, ESP control building, time office, fire station, canteen,dispensory, 1B, ER2, PMH1, 2, 3, RWPH, DM Plant, Chemical house, CWST Pump house, CW Pump house, AWRS Chemical house, TG Building, FOPH building, FGD Control building, Workshop, etc as per scope of work.(NSR)
171Cleaning of all toiletsround the clock of admin building, service building switch yard cotrol building, ESP control building, time office, fire station, canteen,dispensory, 1B, ER2, PMH1, 2, 3, RWPH, DM Plant, Chemical house, CWST Pump house, CW Pump house, AWRS Chemical house, TG Building, FOPH building, FGD Control building,Workshop, etc as per scope of work.(NSR)
172Sweeping cleaning of Store in 1X660 MW, or as directed by E/I (NSR)
173ROAD AND DRAIN CLEANING
174Sweeping & cleaning of roads and side patteries including removal of vegetation. Sweeping of painted bitumen surface brick on edge of road upto side drain For double lane road (NSR)
175Sweeping & cleaning of roads and side patteries including removal of vegetation. Sweeping of painted bitumen surface brick on edge of road upto side drain For single lane road(NSR)
176Cleaning,removal and stacking of deposited material from Trench culvert and siphon such as ash earth debris garbage industrial waste and grass etc. including lift upto 1.5M and lead upto 50M by head load including cleaning of both side patris of drain 1.00 M both side of drain and also including making by pass arrangement to avoid flooding disposal of sludge (measurement shall be done of stacked garbage and 8% deduction shall be made against bulkage including all labour T&P etc.
177Cleaning of sludge ash dirt of any other deposited material from main drain as per direction of E/I including cleaning of culverts on drains both side parties of drain 1.0 Mt. wide on each side cleaning shall be done by making bundah on both sides i.e. upstream as well as down stream and taking out complete sludge and its disposal upto a distance of 1 km. beyond the boundry/premessis of power house/colony disposal of sludge to be done within 07 days of the cleaning All arrangements to avoid flooding & dewatering may be done as required for proper completion of the work. Section wise Quantities are given below: 0.04 to 0.25 Sq. M section
178Cleaning of sludge ash dirt of any other deposited material from main drain as per direction of E/I including cleaning of culverts on drains both side parties of drain 1.0 Mt. wide on each side cleaning shall be done by making bundah on both sides i.e. upstream as well as down stream and taking out complete sludge and its disposal upto a distance of 1 km. beyond the boundry/premessis of power house/colony disposal of sludge to be done within 07 days of the cleaning All arrangements to avoid flooding & dewatering may be done as required for proper completion of the work. Section wise Quantities are given below:0.25 to 0.5 sqm section
179Cleaning of sludge ash dirt of any other deposited material from main drain as per direction of E/I including cleaning of culverts on drains both side parties of drain 1.0 Mt. wide on each side cleaning shall be done by making bundah on both sides i.e. upstream as well as down stream and taking out complete sludge and its disposal upto a distance of 1 km. beyond the boundry/premessis of power house/colony disposal of sludge to be done within 07 days of the cleaning All arrangements to avoid flooding & dewatering may be done as required for proper completion of the work. Section wise Quantities are given below:0.65 to 0.95 sqm section
180Cleaning of sludge ash dirt of any other deposited material from main drain as per direction of E/I including cleaning of culverts on drains both side parties of drain 1.0 Mt. wide on each side cleaning shall be done by making bundah on both sides i.e. upstream as well as down stream and taking out complete sludge and its disposal upto a distance of 1 km. beyond the boundry/premessis of power house/colony disposal of sludge to be done within 07 days of the cleaning All arrangements to avoid flooding & dewatering may be done as required for proper completion of the work. Section wise Quantities are given below: 1.00 to 1.5 sqm section
181Disposal of industrial garbge such as malwa, Ash, grass etc from road side dust bin, roadand stacked malwa / Ash etc which has already removed form roofs and drains and Its disposal up to 2 Km. out side the power house including cost of all labour T&P etc. required for proper completion of work. (20% voids shall be made for Net Qty.) ash,lime, building rubbish.
182Removal of dead animals from Power house area to outside the power house including all labour & T&P complete within same day as per direction of E/I(NSR)
183Hiring of J.C.B./Hydra with driver & fuel for different type of Job as per direction of Engineer Encharge. (NSR)
184Supply of tractor with trolley including driver, fuel and sufficient labour for loading and unloading scrap material in Power house area (various site toscrap yard) etc. complete as direction of E/I.
185Supplying and laying the lime along with Road Side and main gate with help of Roap including all T&P etc. complete. N.S.R.
186Landscape and area grading
187Maintenance of lawn grass/flower beds/permanent bedsincluding cutting of grass with lawn movers (grass cutter), leveling with lawn roller, watering and removing weeds etc, and cutting of hedge in proper shape & height and also trimming of branches of trees, including daily sweeping and cleaning of entire park area clearing jungle and spreading of dump manure fertilizer, pesticides, disposal of malwa/garbage generated due to execution of these work up tonearest dustbin as per instruction of E/I. Rates includes all T&P required for proper completion of work.
188Maintenance of lawn grass/flower beds/permanent bedsincluding cutting of grass with lawn movers (grass cutter), leveling with lawn roller, watering and removing weeds etc, and cutting of hedge in proper shape & height and also trimming of branches of trees, including daily sweeping and cleaning of entire park area clearing jungle and spreading of dump manure fertilizer, pesticides, disposal of malwa/garbage generated due to execution of these work up tonearest dustbin as per instruction of E/I. Rates includes all T&P required for proper completion of work. However consumables such as manure/ fertilizer/ pesticides will be paid extra as per Annexure “B New Type II, Type IV.
189Supply and stacking of well decayed cow dung manure at site including carriage up to 01 K.m. (cow dung manure measured in stack will reduced by 8% for voids. )
190Spreading of dump manure.
191Supply & Sprinkling of herbicide Glyphosale (41.1)along with herbicide urea as Supplement in herbs, grass, jungle area including all material, Labour, T&P etc. for proper completion of work.
192Providing tractor with fuel with trolley with driver & 2no Labour for loading & unloading including carriage of garbage, grass building rubbish etc. For dumping at dumping yard outside/inside the Plant area.
193Supply and lying of various manures /Pesticides.Urea
194Supply and lying of various manures /Pesticides. DAP
195Supply and lying of various manures /Pesticides. Rose Mixture
196Supply and lying of various manures /Pesticides. Neem Khali
197Supply and lying of various manures /Pesticides. Bone Dust
198Supply and lying of various manures /Pesticides. Rogar
199Supplying MosaicGamla. 18”
200Supplying Croton plants not less than 3 feet hight
201Supplying Erocaria plants not less than 3 feet hight
202Supplying Palm Tree plants not less than 3 feet hight
203Supplying Rubber Plants plants not less than 3 feet hight
204Supplying of Guldawdi/Double Dahelia in eathen Gamala 6”
205Supplying/sowing seasonal flower plants saplings in flower beds.
206Supply and sprinkling of herbecide glyphosale (41%) alongwith herbecide urea as suppliment in herbsgrass, jungle area in B&C power house area including all material, labour, T&P etc. for proper completetion of work.
207Maintenance of lawn grass/flower beds/permanent bedsincluding cutting of grass with lawn movers (grass cutter), leveling with lawn roller, watering and removing weeds etc, and cutting of hedge in proper shape & height and also trimming of branches of trees, including daily sweeping and cleaning of entire park area clearing jungle and spreading of dump manure fertilizer, pesticides, disposal of malwa/garbage generated due to execution of these work up tonearest dustbin as per instruction of E/I. Rates includes all T&P required for proper completion of work. However consumables such as manure/ fertilizer/ pesticides will be paid extra as per Annexure “B” Gandhi Park Dus dukan, Market Park, CISF Park, GM Office Park.
208STP
2091.O peration and maintenance of sewage treatment plant of capacity ( 0.03MLD) 30 M3 per day with proper operation of various equipments like air blower motor,dual media filter pump,sludge feed pump, with motor ,centrifuge with motor,centrifuge panel,Hypochlrite dosing pump with motor,pe dosing pump with motor,vertical submersible pump and motor including transfer of sewage from various location of plantand othermisc. works as per guideline ofEngineer-in-charge for adequate O&M of sawage treatment plantincluding mechanical/electrical/instrument maintenance, with cost of labour, material, T&P and tools & tackles etc. as per requirments (Round the clock),Vendor should maintain the operation parameters as per pollution control board like COD, BOD, TSS, Oil & Grease, MLVSS etc.
210Housekeeping of sewage treatment plant area including all building and surrounding the inlet chamber, inspection chamber,screen chamber, grit chamber including all structure and equipment installed there in by way of hand brush and broom including disposal of rubbish, garbage, plastic pieces, pieces of cloths, wooden pieces, fungus, grit, green grass and sapling etc. as per direction of Engineer-in-charge and including of all labour materials and T&P etc. required for proper completion of work(Round the clock).
211Routine operating and backwashing /cleaning ofACF, DMF, Tube Settler , FAB Reactor etc periodically.
212Maintenance & upkeep and repair if necessary of following mechanical and electrical machine including piping installed with different points of sewage treatment plant including removal and replacement of unserviceable part and providing accessories/spares as an when required oiling and greasing etc. required for proper functional efficiency and performance of sewage treatment plant including all labour, materials and T&P etc. required for proper completion of job Mechanism of chlorination (1 Nos.)
213Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge
214periodic Cleaning of all tank including disposal of waste out side the plant area as per direction of E/I including cost of all labour T&P etc. required for proper completion of the work.
215Pumping out sewage from manholes/ sewer line/ surface drain including cost of all materials. Labour & T&P etc. required for proper completion of work by deploying 5HP diesel pump.
216Cleaning of choking of pipes/ sewer pipes of following internal dial byroding from manholes and well flushing after cleaning, including opening and closing of manhole covers and disposal of sludge with 50mtr lead at specified place including cost of all material, labour and T&P etc required for proper completion of work (one no. will be considered for cleaning of particulars dia of pipe lines between two manholes.100mm dia
217Periodical oiling/greasing work, filling of gear oil in gear box and attending maintenance work of sewage treatment plant of capacity (0.03MLD) including complete routine break down maintenance of pumps with moter of 60HP 2Nos. 05HP 02 Nos. 02HP 2 No. 1HPinstalled at STP including alignment of pump with motor its coupling, cost of accessoires/ spares, consumable oil and grease etc. but excluding the cost of shaft bearing, gear, casing, pump coupling, rewinding motors etc. the work includes cleaning and minor maintenance of all valves, NRV etc,. like change of glands, packing, gaskets, bolts & nuts etc. and including cost of all material, labour and T&P etc. required for proper completion of work.
218Rewinding of following capacity three phase vertical or horizontal motor for pump etc. with "B" class insulated copper wire of ISI approved quality including painting, varnishing etc. complete with fiber replacement sleeve for insulation and nuts, bolts, washer etc. all the waste material such as burnt copper wire shall be the property of the contractor.5HP to 2 HP.
219Rewinding of following capacity three phase vertical or horizontal motor for pump etc. with "B" class insulated copper wire of ISI approved quality including painting, varnishing etc. complete with fiber replacement sleeve for insulation and nuts, bolts, washer etc. all the waste material such as burnt copper wire shall be the property of the contractor. 1HP
220P/F of approved make or replacement of damage/ defective spare including oiling greasing etc. complete Belt of approved make