Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SCHEDULE A BOQ |
| 2 | M&Ltaking down of ceiling fan of size 1200/1400mmfor safety checking by replacingdefective parts/painting/rewinding and re-fixing the ceiling fan after repairs,all as specified and as directed by Engr-in-charge. (Note:- The cost for replacement of unserviceable parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional andmaking connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) complete all as specified and directedNote:- Taking down defective parts aredeemed to be inclusive in quoted rate |
| 3 | Note for item No 2 :- (a) In each job, checking the functioning of fan including its connections, cleaning of fan, greasing of fan and mechanical check i.e. tightening of loose screw, nuts, bolts, etc are inclusive in unit quoted rate. |
| 4 | (b)The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced, before commencement of work. |
| 5 | (c)The entire job will be carried out inAir Force stn Sulur and necessary documents showing qtr No, bldg No supported with user signature shall be prepared as per format directed by Engr-in-charge and will be deposited to concerned JE (E/M) within 24 hrs. |
| 6 | (d)Maitenance of documents ie complaint slip/complaint register & other stationery required shall be of contractor\"s responsibility. |
| 7 | (e)Necessary T&P such as ladder, required manpower for taking down and refixing after repair shall be of contractor\"s responsibility. |
| 8 | (f)All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department. |
| 9 | (g)Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing. |
| 10 | (h)In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered. |
| 11 | (j) In case of minor defects, entire job shall be completed within12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered. |
| 12 | (k)The contractor shall maintain a record of all urgent/ routine works and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt. |
| 13 | Supply and fix rotor of ceiling fan of any size complete all as specified and directed. |
| 14 | Supply and fix fan canopies for ceiling fan size of 1200mm/1400mm complete all as specified and directed. |
| 15 | Supply and fix gun metalbush of suitable size for ceiling fan 1200mm /1400 mm sweep complete all as specified and directed. |
| 16 | Supply and fixfan bearing suitable forceiling fan 1200mm /1400 mm sweepcomplete all as specified and directed.(bearing with 8 balls shall be used ) |
| 17 | Supply and fix down rod for ceiling fan with 15mm dia (of length not less than 45cm and not more than 60cm) with hanging clamps for ceiling fan complete all as specified and directed. |
| 18 | Supply and fix Rubber reel bushes for ceiling fan of size 1200/1400mm complete all as specified and directed. |
| 19 | Supply and fix\"U\" clamp for hanging ceiling fan with all nuts, bolts and washers complete all as specified and directed.. |
| 20 | Supply and fix outer body of ceiling fan of any size complete all as specified and directed. |
| 21 | Supply and fix blades (made of aluminum) suitable for 1400mm sweep ceiling fan of any make with set of screws complete all as specifiedand directed. |
| 22 | Supply and fix safety pins 40mm to 50mm longwith nuts and bolt with washers for ceiling fan of size 1200/1400mm complete all as specified and directed. |
| 23 | Supply and fix blades (made of aluminum) suitable for 1200mm sweep ceiling fan of any make with set of screws complete all as specifiedand directed . |
| 24 | Supply and fix down rod for ceiling fan with 15mm dia (of length not less than 90cm and not more than 120cm) with hanging clamps for ceiling fan complete all as specified and directed. |
| 25 | Supply and fix down rod for ceiling fan with 15mm dia (of length not less than 180cm and not more than 210cm) with hanging clamps for ceiling fan complete all as specified and directed. |
| 26 | M&L painting the ceiling fan 1200mm /1400 mm sweep with one coat of syntetic enamel paint as per existing colour/ shades and writing the MES No- as directed by Engr in Charge.Note:-(i)Painting of ceiling fan shall be done inside MES complex only.(ii) Taking down and re hanging of fan shall be measured and paid under relevent item here in above seperately. |
| 27 | Material and labour for winding of ceiling fan motor 1200 mm sweep of any make with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- Motor shall be wound with machine inside MES complex only. |
| 28 | Description all as perSl item No 27 here in above but ceiling fan of 1400 mm sweep |
| 29 | Supply and fixing in repairs of unserviceable energy efficeint Ceiling fan 1200mm sweep(BLDC), energy efficient ISI mark with 5 star rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt andflexible 3 core of size 1.5 sqmm not less than 0.5 m long complete including taking down existing one, writing MES No with synthetic enamel paint all as specified and as directed. Make : Havells Model No. Efficiencia DX BLDC or equivalent inBajaj/ Orient or equivalent approved make.Note:-(a)The contractor shall give a written guarantee of minimum two years from completion of work.(b)Old Unserviceable ceiling fan shall be deposited to MES store yard. |
| 30 | Taking down ofexhuast fan any size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling including replacement of parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional andmaking connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) complete all as specified and directedNote:- Taking down defective parts aredeemed to be inclusive in quoted rate |
| 31 | Note for item No 30 :- (a) In each job, checking the functioning of fan including its connections, cleaning of fan, greasing of fan and mechanical check i.e. tightening of loose screw, nuts, bolts, etc are inclusive in unit quoted rate. |
| 32 | (b)The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced, before commencement of work. |
| 33 | (c)The entire job will be carried out inAir Force stn Sulur and necessary documents showing qtr No, bldg No supported with user signature shall be prepared as per format directed by Engr-in-charge and will be deposited to concerned JE (E/M) within 24 hrs. |
| 34 | (d)Maitenance of documents ie complaint slip/complaint register & other stationery required shall be of contractor\"s responsibility. |
| 35 | (e)Necessary T&P such as ladder, required manpower for taking down and refixing after repair shall be of contractor\"s responsibility. |
| 36 | (f)All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department. |
| 37 | (g)Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing. |
| 38 | (h)In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered. |
| 39 | (j) In case of minor defects, entire job shall be completed within12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered. |
| 40 | (k)The contractor shall maintain a record of all urgent/ routine works and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt. |
| 41 | Material and labour for winding of Exhuast fan 450mm sweep of any make with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- Motor shall be wound with machine inside MES complex only. |
| 42 | Description all as perSl item No 41 here in above but300 mm sweep |
| 43 | Description all as perSl item No 41 here in above but250/230/200 mm sweep |
| 44 | Supply and fix fan bush of suitable size for exhaust fan of the any sweep complete all as specified and directed. |
| 45 | Supply and fix metal louvers of suitable size for exhaust fan of the 450mmsweep complete all as specified and directed. |
| 46 | Supply and fix fan bearing of suitable size for exhaust fan of 450mmsweepincluding greasing complete all as specified and directed.. |
| 47 | Supply and fix metal louvers of suitable size for exhaust fan of the 300mmsweep complete all as specified and directed. |
| 48 | Supply and fix fan bearing of suitable size for exhaust fan of 300mmsweepincluding greasing complete all as specified and directed. |
| 49 | Supply and fix metal louvers of suitable size for exhaust fan of the 250/230/200mmsweep complete all as specified and directed. |
| 50 | Supply and fix fan bearing of suitable size for exhaust fan of 250/230/200mmsweepincluding greasing complete all as specified and directed. |
| 51 | M&L painting the exhaust fan of 450mmsweep with one coat of syntetic enamel paint as per existing shade/ colour and writing the MES No and return to MES storeyard /user unit from the work shop .as directed by Engr in Charge.Note:-Painting of ceiling fan shall be done inside MES complex only. |
| 52 | All as per item No 51 above but 300 mm sweep |
| 53 | All as per item No 51 above but 250/230/200 mm sweep |
| 54 | S&F Domestic Exhaust Fans for kitchen, 300 mm sweep, 230 volt square type, metallic range,corrosion less mild steel body of motor, plastic/ fibre blade for noise less operation,self operating louvers gives powerful performance round the clock, suitable hold fast with necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint complete all as specified and directed.Make- havells model- Ventil air-DB NEO/ DBor equivalent in bajaj, Almonard or equivalent approved make.Note:-Old Unserviceable domestic exhaust fan shall be deposited to MES store yard. |
| 55 | S&F Exhaust fan250 mm sweep 230 volt square type, heavy duty with louvers of PVC body including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint complete all as specified and directed. Make-Havells Cat No Ventil DX-DX-HS or equivalent in bajaj, Crompton Greaves or equivalent approved make.Note:-Old Unserviceable Exhaust fan shall be deposited to MES store yard. |
| 56 | S&F Exhaust fan200 mm sweep 230 volt square type, heavy duty with louvers of PVC body including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells Cat No Ventil DX-DX/HS or equivalent in bajaj, Crompton Greaves or equivalent approved make.Note:-Old Unserviceable Exhaust fan shall be deposited to MES store yard. |
| 57 | S&F Exhaust fan150 mm sweep 230 volt square type, heavy duty with louvers of PVC body including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint complete all as specified and directed.Make-Havells Cat No Ventil DX-DX/HS or equivalent in bajaj, Crompton Greaves or equivalent approved make.Note:-Old Unserviceable Exhaust fan shall be deposited to MES store yard. |
| 58 | M&L for windingof pedastal fan of 630 mm sweep of any make, cleaning the slotswith super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- Motor shall be wound with machine inside MES complex only. |
| 59 | Description all as perSl item No 58 here in above but450 mm sweep |
| 60 | Description all as perSl item No 58 here in above but 400 mm sweep |
| 61 | Supply and fix in repairs fan bush of suitable size for pedestal fan ofany sweep complete all as specified and directed. |
| 62 | Supply and fix in repairs fan bearing of suitable size for pedestal fan of 630 mm sweep complete all as specified and directed. |
| 63 | Description all as perSl item No 62 here in above but450 mm sweep |
| 64 | Description all as perSl item No 62 here in above but 400 mm sweep |
| 65 | M&L painting the pedestal fan of 630 mm sweep with one coat of syntetic enamel paint as exiting colour and writing the MES No and return to MES storeyard /user unit from the work shop as directed by Engr in Charge. |
| 66 | Description all as perSl item No 65 here in above but 450 mm sweep |
| 67 | Description all as perSl item No 65 here in above but 400 mm sweep |
| 68 | Taking down of wall mounted fanany size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling complete all as specified and directed. .(Note:- Repair, rewinding, over hauling and materials to be replaced are measured seperately.) |
| 69 | Note for item No 68 :- (a) In each job, checking the functioning of fan including its connections, cleaning of fan, greasing of fan and mechanical check i.e. tightening of loose screw, nuts, bolts, etc are inclusive in unit quoted rate. |
| 70 | (b)The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced, before commencement of work. |
| 71 | (c)The entire job will be carried out inAir Force stn Sulur and necessary documents showing qtr No, bldg No supported with user signature shall be prepared as per format directed by Engr-in-charge and will be deposited to concerned JE (E/M) within 24 hrs. |
| 72 | (d)Maitenance of documents ie complaint slip/complaint register & other stationery required shall be of contractor\"s responsibility. |
| 73 | (e)Necessary T&P such as ladder, required manpower for taking down and refixing after repair shall be of contractor\"s responsibility. |
| 74 | (f)All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department. |
| 75 | (g)Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing. |
| 76 | (h)In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered. |
| 77 | (j) In case of minor defects, entire job shall be completed within12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered. |
| 78 | (k)The contractor shall maintain a record of all urgent/ routine works and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt. |
| 79 | Supply and fix fan bearing of suitable size for wall mounted fan of 400 mmsweep. |
| 80 | Supply and fixbush of suitable size for wall mounted fan of the any sweep |
| 81 | Material and labour for winding of wall mounted fan630mm sweep of any make with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- Motor shall be wound with machine inside MES complex only. |
| 82 | Description all as perSl item No 81 here in above but 400 mm sweep |
| 83 | S&F wall mounted fan 300 mm sweep, power input 55 watt, 1380 RPM, air delivery-75 CMM, single phase 230 volts high performance motor with over heat protection world class styling & finish, facility to control wind & nature mode, aerodynamically designed balanced AS blades includingfixing arrangement on wall including taking down existing one writing MES No with synthetic enamel paint all as specified and directed. Make:- Havells Model -Swing HS, Bajaj or Polar or equivalent approved make.Note:-Old Unserviceable wall mounted fan shall be deposited to MES store yard. |
| 84 | Supply & fix 4 mfd condensor for ceiling fan complete all as specified and directed. Make : Epcos/ Asian/ Tyton or equivalent approved make. |
| 85 | Supply & fix 2.5 mfd condensor for ceiling fan complete all as specified and directed. Make : Epcos/ Asian/ Tyton or equivalent approved make. |
| 86 | Supply and fix in repairs switch piano flush type 5 Amps240 volts single pole one way complete all as specified and directed.Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline) or equivalent approved make. |
| 87 | Supply and fix in repairsCeiling rose 3 plates flush type 6 Amps,250 volts ACISI marked complete all as specified and directed., |
| 88 | Supply and fix in repairs electronicfan regulator 230 volts, step type socket type, hum free 100/240 watt complete all as specified and directed.Make :Havells / Schnieder/ crabtree or equivalent approved make. |
| 89 | Supply and fix in repairs electronicfan regulator modular type 230 volts, step type socket type, hum free 100/240 watt complete all as specified and directed. Make :Havells / Schnieder/ Crabtree or equivalent approved make. |
| 90 | Supply and fix in repairs modular switch1 way 6 amp.1 modulecomplete all as specified and directed.Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make. |
| 91 | Supply and fix in repairs electronic fan regulator 230 volts, step type, switch type, hum free 100/ 240 wattcomplete all as specified and as directed.Make : Anchor/ Cona/ Havells or equivalent approved make. |
| 92 | Inspection,checking alignment and minor repairs of storage water heater 25/35/50 ltr capacity of any type any make vertical/ horizontal type which includes the following complete all as specified and directed:-(a) Inspection, taking down the defective parts, taking out of drain plug & dewatering and refix the same complete all as directed .(b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts.(d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow.(e) Checking and correct earth continuity of electrical items.(f)Checking functioning of heating elementand correct setting adjustment of thermostat upto 55º C.(g) Alignment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness.(h) Replacement of defective spares shall be measured and paid under relevant items mentioned below separately as supply and fix. |
| 93 | Note for item No 92 :- |
| 94 | The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced, before commencement of work. |
| 95 | The entire job will be carried out in entire Tech area of Air Force stn Sulur and necessary documents showing qtr No, bldg No supported with user signature shall be prepared as per format given by Engr-in-charge and will be deposited to concerned JE (E/M) within 24 hrs. |
| 96 | All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department. |
| 97 | S&F Heating element, thread type, 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity and any make including washer/packing suitably complete all as specified and as directed. Make:- Theeta/Swarna or equivalent approved make. |
| 98 | Supply and fix pressure relieving valve CP brass confirming to relevant IS with washer suitable for 15mm bore GI pipe suitable for 25/50 ltrs geysers complete all as specified and as directed. Make : Leader / Theta or equivalent approved make. |
| 99 | Supply and fixthermostat switch range of 30-80 degree suitablefor geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed. Make : Havells/Theeta/Swarna/ Elcon or equivalent approved make. |
| 100 | S&F Glass wool for insulation of Geysers any capacity and any makecomplete all as directed by the Engr-in-Charge. |
| 101 | S&F Heating element, tikona type, 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity and any make including taking down old one including washer/packing suitablycomplete all as specified and as directed. Make :Theeta/Swarna or equivalent approved make. |
| 102 | S&F PVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 450 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe complete all as specified and as directed. |
| 103 | S&F Indicator lamp for geyser 25/50 ltr capacity ofcolour green & red complete all as specified and as directed.Make : Usha / Bajaj/ Crompton or equivalent approved make. |
| 104 | S&F Copper inner tank of minimum 20 gauge sheet rated pressure not less than 7kg/sqcm suitable for 25 ltrs capacity geysers (wt not less than 3.75 kg) as per sample complete all as specified and as directed. |
| 105 | Supply and fixbrass non return valves, screwed down, high pressure, screwed both ends for 15mm bore iron pipe or for union, ISI marked, complete all as specified and as directed. Make :Seiko, Leader, Zoloto or equivalent approved make. |
| 106 | M & L Cutting and screwing existing steel water tubing 15/20/25 mm bore for addition /alteration required for connections to geysers etccomplete all as specified and directed. |
| 107 | Supply and fixbottom cover of MS sheet 20 gauge suitable for 25 ltrs capacity geysers and providing a coat of red oxide primer to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed. |
| 108 | S&F provision brazing of inner copper tank Geysers using quality of copper electrode blow lamp welding process brazing length n.exc 10 cm all as specified and directed at site the Engr-in-Charge. |
| 109 | Supply and heating element, cup (square) type, 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity and any make including taking down old one including washer/packing suitablecomplete all as specified and as directed. Make : Theeta/Swarna or equivalent approved make. |
| 110 | Supply and fix PVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 600 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe complete all as specified and as directed. |
| 111 | Taking down carefully storage water heater (geyser) 25 ltr capacity of any type, any make from the location by removing the electric & water supply connection and shifted to work shop/MES store yard for repair and re-installation at any location including S&F in repair of heavy duty pin type fastener 4\" long and making necessary inlet/outlet electric & water supply connection from existing source to geyser complete all as specified and as directed. |
| 112 | Description all as per Sl item No. 111 here-in-above but 35/50 Ltr capacity. |
| 113 | S&F Heating element, tikona type, 2.00 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity and any make including provision of suitable washer/packing complete all as specified and as directed. Make : Theeta/Swarna or equivalent approved make. |
| 114 | M&L for painting of outer surface of 25 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed. |
| 115 | Supply and fix indoorassembly, compatible to existing geyser, 25 Ltr capacity in any make, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified and as directed. |
| 116 | S&F Copper inner tank of minimum 20 gauge sheet rated pressure not less than 7 Kg/sqcm suitable for 35/50 ltrs capacity geysers (wt not less than 5.25 kg) as per sample complete all as specified and as directed. |
| 117 | Supply and fix bottom cover of MS sheet 20 gauge suitable for 35/50 ltrs capacity geysers and providing a coat of red oxide primer to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed. |
| 118 | M&L Bottom cover in two pieces for covering the base plate, heating element, thermostat made out of MS sheet 22 gauge as per existing size and shape duly painted with two coat of white synthetic enamel paint over one coat of red oxide primer including preparation of surfaces completeall as specified and as directed. |
| 119 | S&F Heating element, thread type, 2.00 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity and any make including taking down old one inlcuding washer/packing suitable complete all as specified and as directed.Make : Theeta/Swarna or equivalent approved make. |
| 120 | Supply and fix 35/50 Ltr capacity in any make indoorassembly, compatible to existing geyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified and as directed. |
| 121 | Supply and fix in repairsWater heater with Water heater storage type, vertical, electric single phase 240 V, 2 KW heating element, Capacity 25 ltrs, BEE 5 star rated complete all as specified and directed.Make- Havells, Model No. Monza DX Cat part No. GHWAMGTWH025 white colour or Recold, Bajaj. Note :- (a) The Contractor shall given a written guarantee of minimum two years from completion of work. |
| 122 | Dismantling carefully solar storage water heating system including taking down old defective parts of any capacity, any type for following works withtestingand refixing the same in original position including all water/ electric connection to entire satisfaction of Engineer-in-charge after carry out servicing as under :- (a) Inspection, opening, of all parts,descaling, washing of inner tankwith chemical solution and cleaning ofouter cover storage tank.(b) Checking water tightness of storage tank after cleaning.(c) Checking and correcting earth continuity of electrical items.(d) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (e) Replacement of damaged solar cells (solar cell shall be measured and paid separately under relevant item)(f)Necessary T&P such as ladder,helper shall be contractor responsibiliy. |
| 123 | M&L for painting of outer surface of 50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed. |
| 124 | Supply and fix thermostat switch suitable for solar water heater of any make and size complete all as specified and as directed. Make : USHA / Bajaj / Recold / Theta or equivalent approved make. |
| 125 | Supply and fix heating element 3 KW, 230 volt ISI marked suitable for solar geyser tank of any make, any size complete all as specified and as directed. Make : Theta / Daspas / Recold / Bajaj or equivalent approved make. |
| 126 | Supply and fix Gasket setfor solar water heater panel suitable for 100Ltr capacity complete all as specified and as directed. |
| 127 | Supply and fix in repairs rotational moulded 300 litres capacity double layered HDPE water storage tanks cylindtrical vertical with closed top as per IS 12701-1996 hoisted and fixed in position, including provn of inlet pipe, over flow pipe, washout pipe etc complete all as specified in SSR Part I and as directed. |
| 128 | Supply and fix in repairsbib taps, cast copper alloy, with crutch or butterfly handle, chromium plated, fancy type, screwed down, screwed for 15mm bore iron pipe, ISI marked, complete all as specified and as directed. Make: Seiko, Leader, Jaguar or equivalent approved make. |
| 129 | Supply and fixin repairssolar cellsin thesolar panel for solar water heater 100 Ltr capacity complete all as specified and as directed. |
| 130 | Supply and fix in repairssolar tube as per exisiting type complete all as specified and as directed. |
| 131 | Supply and fixin repairs industrial type metal clad plug top & socket single pole and a natural link earth enclosure with MCB SP 20 Amp complete all as specified and as directed. |
| 132 | S&Fin repairsStop valves, 15 mm Bore of pipe in mm fancy type, chromium plated , high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 133 | Supply and fixin repairsball brass valve high pressure with polythene float and fly nut complete screwed for iron pipe 25mm bore complete all as specified and as directed. |
| 134 | S&Fin repairsPVCwater storage tank cover suitable for 250/ 300 ltrs capacity tank with locking arrangement complete all as specified and directed |
| 135 | Supply and fixin repairs solar panel glass suitable for 100 ltrs capacity solar water heater with gasket complete all as specified and as directed. |
| 136 | Supply and fixin repairssolar water heater tank 100 ltr capacity tank having 1.60 mm thickness low carbon steel with porcelain coating, outer tank should be 0.4 mm thickness stainless steel 202 grade Non Magenetic grade, insulation is PUF 50mm including provn for suitable solar tubes complete all as specified and directed. |
| 137 | Supply and fixingin repairsMCB SPN 32/40 amps 240 V complete all as specified and as directed. |
| 138 | S&Fin repairs 3 layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN-16) UV stablized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain and brass threaded polypropylene random fittings fixed complete to walls/ceilings or floors of 32mm (outer dia of pipe) complete all as specified and as directed.Make : Supreme, KPT, Prince or equivalent approved make. |
| 139 | S&F in repairs 3 layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN-16) UV stablized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain and brass threaded polypropylene random fittings fixed complete to walls/ceilings or floors of 25mm (outer dia of pipe) complete all as specified and as directed.Make : Supreme, KPT, Prince or equivalent approved make. |
| 140 | Note for item No 138 & 139 :-(a)The unit rate shall be include for taking down existing pipe and connections and all fittings as directed. |
| 141 | (b) The unit rate shall be include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc |
| 142 | (c ) Wall thickness of pipes shall be all as per IS : 15801 |
| 143 | Supply and fix ball brass valve high pressure with polythene float and fly nut complete screwed for iron pipe 20mm borecomplete all as specified and as directed. |
| 144 | Cleaning of service tanks of 250/ 300 ltrs capacity on roof top of bldgs upto five storrey after disconnection from inlet and outlet pipe, removing of float valve of service tank and keep aside safely for reuse drain out water through drain plug, cleaning thoroughly to remove all scales and dirt by brushing internal surface, cleaning properlyinside with soda wash, flushing out with fresh water, re-positioning of tank at same place, re-connecting inlet and outlet pipes, closing of drain plug, re-installation of float valve duly cleaned, writing/ labelling the record of cleaning carried out with white bold letter such as\"TANK CLEANED ON\"--------- (month and year), including removing creepers, vegitation and roots of plants, trees branches on or surrounding of service tank complete all as directed. |
| 145 | M&L for Staging / frame work for Solar water tanks using standard mild steel sections like angle iron / MS pipe / flat iron / sheets etc using steel of Fe 410-W (Gde E-250) quality - A including necessary welding suitable to keep 300 ltrs PVC water tank including taking down existing frame work complete all as specified and directed by Engr in charge. |
| 146 | M & LPreparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide zinc chrome primer completeall as specified and directed. |
| 147 | Note for item No 146:-(a) All synthetic enamel paint, plastic emulsion paint shall be of 1st quality manufactured by the standard firms of make as specified. |
| 148 | (b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works. |
| 149 | (c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE. |
| 150 | (d)Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite) |
| 151 | (e )Unless otherwise specified the tints of paint shall be as approved by the GE |
| 152 | (f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval. |
| 153 | (g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge. |
| 154 | (h) No hair marks from the brushor clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory. |