Delhi Transport Corporation has published Tender For Renovation Work Of Electrical Installation Of Workshop, Service Pits, Washing Plant And Some Allied Work At Dtc Rohini Depot- I. Submission Date for this Tender is 17-05-2023. Electrical Maintenance Tenders in rohini Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
2 | Group C |
3 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
4 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
5 | Wiring for circuit/ submain wiring along with earth wire with the followingsizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
6 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
7 | 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire |
8 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. |
9 | 5 x 4 sq. mm |
10 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
11 | 25 mm |
12 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
13 | 5/6 A switch |
14 | 15/16 A switch |
15 | 3 pin 5/6 A socket outlet |
16 | 6 pin 15/16 A socket outlet |
17 | Supplying and fixing metal box of following sizes (nominal size)on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
18 | 180 mm X 100 mm X 60 mm deep |
19 | 250 mm X 300 mm X 60 mm deep |
20 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
21 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
22 | 100 A, 16 kA,TPMCCB |
23 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) |
24 | 8 way, Double door |
25 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
26 | 8 way (4 + 24), Double door |
27 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
28 | 6 way (4 + 18), Double door |
29 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
30 | Single pole |
31 | Triple pole |
32 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
33 | 63A |
34 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
35 | 63 A |
36 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A, "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
37 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A, "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
38 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
39 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
40 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
41 | 2 X 16 sq. mm (22mm) |
42 | 3½ X 95 sq. mm (45 mm) |
43 | 4 X 16 sq. mm (28mm) |
44 | 4 X 25 sq. mm (28mm) |
45 | 4 X 35 sq. mm (28mm) |
46 | Supply of XPLE insulated PVC sheathed AL conductor cable 1.1 KV grade conforming to IS-7098 of size 2X16 sq. mm. |
47 | Supply of XPLE insulated PVC sheathed AL conductor cable 1.1 KV grade conforming to IS-7098 of size 4X16 sq. mm. |
48 | Supply of XPLE insulated PVC sheathed AL conductor cable 1.1 KV grade conforming to IS-7098 of size 4X25 sq. mm. |
49 | S/I/T/C of LED tube fitting 20 watt |
50 | S/I/T/C of 450mmindustrial Wall mounting fan |
51 | S/I/T/C of LED flood Light 100 watt |
52 | S/I/T/C of led panel 36 watts 2"X2" |
53 | S/I/T/C of 300mmExhaust fan |
54 | Dismantling work of old/defective electrical installation as site required |
55 | (+)Add prevailing cost index @ 22.69% On DSR-2016 rate) |
56 | (-) @ 9.5% below on (DSR-2016 Rate + Add prevailing cost index @ 22.69% |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy