New Okhla Industrial Development Authority-NOIDA has published Tender For Supply, Installation, Testing And Commissioning Of Diesel Generating Set At Command Control Center, Sector-94, Noida. Submission Date for this Tender is 15-05-2023. Diesel Generators Tenders in noida Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Supply, Installation, Erecting, testing and commissionig etc. of Silent Type Diesel Generating Set of 160 KVA, 3 phase & neutral, 50 c/s. 415 A.C. rating, comprising ofDiesel Engine, Alternator, Acoustic enclosure conforming to latest environment protection requlations for emmission and noise levels as required and with other associated accessories including the cost of additional AVM pad as reuired. |
2 | A. DIESEL ENGINE: 1.Type: Multi-cylinder water cooled with Radiator, Turbo charged with charge air cooling. |
3 | 2. No. of strokes: 4 |
4 | 3. Fuelinjection :Direct |
5 | 4. Maximum speed : 1500 RPM |
6 | 5.Rated power :as per standards |
7 | 6. Cooling : Water cooled with radiator |
8 | 7. Engine: Battery starting. |
9 | 8. Starting:Universal.Auto/Manual |
10 | B.ALTERNATOR; |
11 | Type:Brushless. |
12 | Actual Power : 160 KVA |
13 | Rated power :as per standards |
14 | Frequency : 50 Cycles/sec. |
15 | Supply system :3 phases & neutral |
16 | Connection:Star. |
17 | Rated voltage: 415 Volts. |
18 | Rated rpm. : 1500 rpm. max. |
19 | Casing: As per IP-23 protection |
20 | Insulation : Class `H". |
21 | Voltage: Automatic voltage |
22 | regulatorregulator (Motorised) |
23 | Power factor : 0.8. |
24 | Controller : Type PCC 3.3 or similar |
25 | C.ACCESSORIES: |
26 | The DieselEngine shall be equipped with minimum following/ as indicated in the specifications, devices/ accessories built-in type including all standard fittings. |
27 | Fuel supply pump with manual venting pump. |
28 | Radiator |
29 | Turbo charger with air filter (dry/oil bath type) and damper. |
30 | Charge air cooler. |
31 | Suction fuelfilter |
32 | Lube oil filter. |
33 | Hourmeter and RPM indicator. |
34 | BatteryStarting Mechanism. |
35 | Instrument/Indication panel complete with the followings; |
36 | a)Starting Switch with key. |
37 | c)Lub. Oil pressure gauge. |
38 | Control devices for safety and monitoring alongwith indicators. |
39 | D.OTHER ACCESSORIES/EQUIPMENT |
40 | AMF PANEL - Alternator shall have its AMF control panel |
41 | Common base/foundation frame. |
42 | Fly wheel and flexible coupling. |
43 | Automatic voltage regulator (AVR). |
44 | Lub oil filter. |
45 | Fuel oil filter. |
46 | Day storage tank of standarad ltr capacity fabricated out of 3mm thick MS sheet, with M.S. fuel pipe line, high & low level indicator and alarm contacts. |
47 | Residential type silencer |
48 | Anti vibration pads |
49 | Necessary batterys ( minimum 1 of 180 AH capacity) with leads andmounting frame etc. |
50 | The cost of initial charge of lubricants, coolant etc |
51 | 1 No. of 250 Amp. Rating, microprocessor based release MCCB, complete with metering, indications and relays/releases as required. All the above housed in a suitable Sound attenuated enclouser as per specifications and required |
52 | SUB HEAD - II - LT PANEL LT PANEL SECTOR-1 (2850x400x2175mm) Supplying, Installation, Testing and Commissioning of 415V, 3 Phase, 50 Hz., 4 wire system sheet steel clad dust and vermin proof cubical and Indoor type floor mounted, free standing extendible type Main M.V. Panel compartmentalized design and fabricated out of 2 mm CRCA sheet steel complete with Aluminium Bus bar ofAmps., Electrical interlocks as per the various status of all the equipments indicated on the drawings. Providing & Fixing of base plate / channel, P/F the following Switchgears, complete with earth Bus bar throughout the length of the panel, terminal arrangement for cables Incomings / Outgoings and also outgoing terminations for various sizes of cables, The incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement, adequate size cable alley, Sign writing, Painting, Earthing, Numbering, Danger plate etc. complete as required as per specifications and drawing attached. Make:- Tricoline/Neptune/Bamaa Power Control System/Advance Pannel. |
53 | Incomings: - One (1) No.,400 A, 433V, 25 kA (Ics=Icu=Icw=25 kA for 1 second), 4 Pole Motorised MCCB,with all indications, metering, protections, push buttons etc. complete in all respects as mentioned in specifications and as required. (From Transformer) |
54 | One (1) No.,315 A, 433V, 25 kA (Ics=Icu=Icw=25 kA for 1 second), 4 Pole Motorised MCCB,with all indications, metering, protections, push buttons etc. complete in all respects as mentioned in specifications and as required. (From DG) |
55 | Bus Bars: 500 Amp.TPN 25Ka, Al. Bus Bar |
56 | Outgoings: - Following rated, 433V, 25kA, MCCB’s,with all indications, Multifunction meter with suitable CT"s etc. complete in all respects as mentioned in specifications and as required. |
57 | 250A 4P MCCB - 4 Nos. (FIRE FIGHTING PANEL+ VENTILATION & PRESSURIZATION PANEL-1 + VENTILATION & PRESSURIZATION PANEL-2 + 1 Spare) |
58 | 200A TPN MCCB - 1 No. (CAPACITOR PANEL) |
59 | 100A 4P MCCB - 2 Nos. (L&P PANEL + 1 Spare) |
60 | 63A 4P MCCB - 5 Nos. (PLUMBING PANEL + EXTERNAL DEVELOPMENT +3 Spare) |
61 | LT panel Sector-1 Described as above. |
62 | "S/L of Al. armoured cable PVC insulated Ar. served & sheathed cable 1100 V grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by the E/I.Complete in all respects . The armouring of the cable shall be properly connected with the earth conductor by clamps etc. UPPWD-2018, PS-501 |
63 | 1)- 25 sq. mm 3.5 core |
64 | 2) 50 Sq.mm. 3½ Core |
65 | "S/F of Plain or Pin type copper tin plated cable socket (Lug)to the cable lead, insulating with tape and making connector etc. Complete in all respects as per Direction of E/I UPPWD-2019, PS-504 |
66 | 1)-25 sq. mm |
67 | 2)- 50 sq. mm |
68 | Supplying and laying of 90 mm dia (OD-90 mm & ID-76 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required DSR-Electrical-2018, 14.16.2 |
69 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. UPPWD-2018, PS 725B |
70 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. UPPWD-2018, PS-725A |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy