Tender For Comprehensive Maintenance And Repairs To Flooring, Plastering, Plinth Protection And Other Misc B / R Works In Officers And Omq Accommodation Zone A Akash Vihar At Af Stn Suratgarh, suratgarh-Rajasthan

Military Engineer Services-MES has published Tender For Comprehensive Maintenance And Repairs To Flooring, Plastering, Plinth Protection And Other Misc B / R Works In Officers And Omq Accommodation Zone A Akash Vihar At Af Stn Suratgarh. Submission Date for this Tender is 29-05-2023. Civil Work Tenders in suratgarh Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

37581374
Tender For Comprehensive Maintenance And Repairs To Flooring, Plastering, Plinth Protection And Other Misc B / R Works In Officers And Omq Accommodation Zone A Akash Vihar At Af Stn Suratgarh
Open Tender
Indian
Rajasthan
suratgarh
29-05-2023

Tender Details

Comprehensive Maintenance And Repairs To Flooring, Plastering, Plinth Protection And Other Misc B / R Works In Officers And Omq Accommodation Zone A Akash Vihar At Af Stn Suratgarh

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: COMPREHENSIVE MAINT AND REPAIRS TO FLOORING, PLASTERING, PLINTH PROTECTION AND OTHER MISC B/R WORKS IN OFFICERS AND OMQ ACCN ZONE "A"AKASH VIHARAT AF STN SURATGARH
Sl. No. Item Description
1BOQ (COMPREHENSIVE MAINT AND REPAIRS TO FLOORING, PLASTERING, PLINTH PROTECTION AND OTHER MISC B/R WORKS IN OFFICERS AND OMQ ACCN ZONE "A"AKASH VIHARAT AF STN SURATGARH )
2Taking down chowkats or frames including shutters (without taking off shutters from the frame) not exc. 1.5 Sqm each, complete all as specified and directed.
3Taking down chowkats or frames including shutters (without taking off shutters from the frame) exc. 1.5 Sqm but n exc 4.0 sqm each, complete all as specified and directed.
4Taking down shutters of any description exc. 1 sqm and not exc. 2 Sqm each, complete all as specified and directed.
5M&LforPressedsteelframesofsize105mmx60mmmadeof 1.25mm thick Cold Rolled sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, PCC 1:3:6 Type B0 , for filling of hollow portion, complete all as specified and directed.
6M&LforPressedsteelframesofsize125mmx60mmmadeof 1.25mm thick Cold Rolled sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, PCC 1:3:6 Type B0 for filling of hollow portion, complete all as specified and directed.
7S&F35mm thick factory made 2nd class hard wood (Sal/ Hollock) plain,framed,panelledshutters(twopanels)withlockrailand panels of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial face veneers on both sides.The size of rail andstilesasperIS–1003(Part-I),kilnseasonedandchemically pressure treated, fitted to chowkats, complete all as specified and directed.
8S&F 35mm thick factory made 2ndclasshardwood (Sal/ Hollock) glazed and skeltonshuttersopen rebated and prepare to receive glass guage (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass/guageetcsize of memberetc size of members ofshutters as specifiedinSSRpartISection-8clauses8.24(a)suppliedand fitted to chowkhat, complete all as specified and directed.
9M&L for prepration of new or previously untreated wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed.
10S&Fbutthinges,mediumweight,coldrolled,mildsteel100mm long (ISI marked), complete all as specified and directed.
11S&F Aluminum handles, 150 mm size plate type complete all as specified and directed.
12S&F aluminium anodised, barrel tower bolt of extruded section and fixed, 200mm long (ISI marked), complete all as specified and directed.
13S&F aluminium alloy, 16mm dia and 250mm long anodised, sliding door bolt with hasp, staple (bolt type) with and fixing clips of sheet, castorexcludedsectionsandfixingboltsandslidingboltsof extruded sections or cast aluminum alloy and fixed, complete all as specified and directed.
14S&F Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like including all necessary labours, articles n exc 200 Cu.cm each in 2nd class Hard Wood complete all as specified and directed.
15M&Lfordoor seal rubberbeading75 mm wide4 mm thickforfixingwithdoor shutter andsimilarsituationincludingnecessarydrillingandcuttingetc, complete all as specified and directed.
16S&F Anodised aluminium door shutter having150mm x 44mm x 2.85 mm thick bottom rail,150 mm x 44mm x 2.85mm thickmiddle rail, 100mm x44mm x3 mm thick stile and top rail including necessary fitting joinery cleat, glazing packing snap beading 10 mm x 10 mm ,anodised aluminium handle 200 mm long (02 Nos) , 3 Nos 100 mm size chromium plated butt hinges, 2 Nos 200mm size aluminium tower bolt, 1No aluminium alloy, 16mm dia and 250mm long anodised, sliding door bolt with hasp, staple (bolt type), 1No double legged floor door stopper aluminum alloy body and tongue, 1 No Aluminium body hydraulically door closer , designation No-3, universal type, weight between 61 to 80 kg etc inlcuding frame of section 100 mm x 44 mm x3 mm and door shutter, top and bottom portion covered with and including5.5mm thick tint glass ordinary quality , onemortice lock (Make: Harrison ) with shutter and fixing complete all as specified and directed.
17S&F Aluminum window and ventilator shutters, sliding type with four track (two track with and including galvanised mild steel wire cloth 0.50 mm nominal dia of wire & average width of aperature 1.00 mm and fixed with tinted tacks or galvanised wire staples, two track with andincluding 4.8 mm thick tined glass including necessary fitting and fixture)without sash bars, aluminum sections of size 40x20x1.5 mm fixed in aluminum anodised double frame of section size 63X35X2 mm including necessary jointing cleats, glazing clips, aluminum anodised snap beading, screws, aluminium beading, pvc packing, aluminum anodised fitting and fixture including aluminium chequered grills as on aluminium windows weight not less than 1.0 kg/sqm complete all as specified and directed.
18S&F factorymadesteelwindowboxtypeusingERWhollow"P" sectioncomprisingdoubleframeforglazedandgauged skelton shutters jointing internally with flat ironcomplete including grillof12mmsquarebar,fixedhorizontally@100mmcentreto centrehinges,handle,towerbolts,lugsetcwithcoolerprovision complete all as specified and as directed. Note:-(i)Forthepurposeofmeasurementandpaymentdouble shutter with frame shall be consider as one unit. (ii) Glazing and wire mesh shall be measured and paid for separately in respective item of schedule.
19S&F Stainless Steelwire cloth0.56mmnominaldiaofwire and average width of aperture 1.18mm fixed with tinned tacks, wire staples or beading etc, complete all as specified and directed.
20S&F in repairsStainless Steelwire cloth0.56mmnominaldiaofwire and average width of aperture 1.18mm fixed with tinned tacks, wire staplesorbeadingetc, completeallasspecified and directed.
21Hackingoutoldbrokenglass(anythickness,size,qualityor description)fromwooden frame/steelframeor stone,concreteor brick surrounds, glazed with putty or fixed with beads, exc 1.5 sqm, complete all as specified and directed.
22M&L for sheet glass 3mm thick ordinary quality and glazing with oil putty or wooden beads in squares not exc. 0.5 Sqm in each pane, complete all as specified and directed.
23Supply and fix in repairs factory made mild steel cupboards shutters 1 mm thick with frame made from 1.25 mm thick sheet including all fittings i.e. mortice lock with handle ,buttt hinges ,peg set of their,etc including two coat of synthetic paint over a coat primer after preparation of surfacescomplete all as specified and directed.
24M&L in repairs for 18 mm thick solid PVC sheetUPVC Coated Celuka printedin one or two different colours( with wood grain printed pattern/ivory colour finish) as in kitchen cabinet shutters ,all round body of cabinets , shelves ,drawers etc cut to required size jointed with solvent cement & steel screws etc complete all as specified & directed.
25S&F in repairs polyvinyl chloride (PVC) sheetframe of width 100 mm & 18 mm thickness made out of extruded 18mm PVC sheet andjoined with suitable Cement Solvent adhesive and screw.Theframe shall be fixed to the wall using 75mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 3nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers instruction and specified.
26Extra over solid PVC sheet for fixing in repairs 18 mm width & 2-3 mm thick PVC coloured lipping of approved design & colour fixed with solvent cement or headless nails complete all as directed & specified .
27S&F in repairs 0 degree clip type self closing hinges for cabinets fixed with cadmium coated screws as per sample complete all as specified and directed.
28S&F in repairs 75mm size bright finished chromium plated steel handleof approved shape & design fixed with cadmium coated screws on the kitchen cabinet drawers complete all as specified and directed.
29S&F in repairs drawer runners folding typewith guide channels & sliding channel with appropriate ball bearing/ rollers etc complete to obtain smooth movement of the drawers complete all as specified and directed.
30M&L in repairs for stainless steel tray as per trade patternof various sizes for drawer to keep the kitchen utensil complete all as specified and directed.
31S&Fstainlesssteel 25mmdia curtainrod includingstainless steel brackets and stainless steel end knobsfixedwith plugs & screws, complete all as specified and directed.
32Dismantling of wall and ceiling or insulation boards/ slabs / PVC panelling any thickness and in any position incl frame grid and cover fillets and framework etc complete all as specified and directed.
33S&F 12mm thick plain gypsum board false ceiling with GI frame work including all necessary drilling, cutting to fix electical items complete all as specified and directed with followings:-(a) GI sheet channel 30x25x20mm of 24 Gauge fixed with rawl plug and screws 450mm centre to centre along with perimeter of walls.b) GI sheet channel made to shape 50x40x40mm of 24 guage placed @ 600mm centre to centre from perimeter of wall except long wall (in one span)(b) GI sheet channel made to shape 50x40x40mm of 24 guage placed @ 600mm centre to centre from perimeter of wall except long wall (in one span) (c) GI sheet intermediate runners of size 45x10x10mm of 24 guage fixed @ 1200mm centre to centre leaving frame of one side wall (in other span) (d) GI sheet 25mm wide & 20mm gauge suspenders fixed with steel fasteners to roof, ceiling @ 1200 mm centre to centre incl plugging in RCC slab complete all as specified and directed.
34M&L prefabricated, 75mm wide POP moulded cornices, moulding fixed on ceiling/wall complete all as specified and directed.
35M&L prefabricated, pre reinforced, 600mm dia POP moulded designer circle dooms fixed on ceiling/wall complete all as specified and directed.
36S&F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC Frame complete all as specified & directed by Engr -in charge.
37S&F PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified & directed by Engr -in charge.
38Demolitionofcementconcreteingroundfloorsandpavingnot exceeding15cmthickness(beloworabovegroundlevel)un- reinforced, complete all as specified and directed.
39M&L for PCC(1:2:4) type B2 (40mm graded stone aggregate) filling in post holes, surface channels, drains and other similar work complete all as specified and directed.
40Dismantling mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in-Charge
41S&F mild steel forframed structure liketrrussed, purlins, crane gantries,postrails and fastenings and heavy bracket framming (Beam,Tee, Angle, Channels, tubes,flate sections) including distance pieces, cleats etc conforming to Fe410-W (Gde-E-250) quality-A complete all as specified and directed.
42Dismantling Asbestos Cement (Corrugated, Semi corrugated etc.) sheets in roof coveringscomplete all as specified and directed by Engr-in-Charge.
43M&L for pre painted galvalume aluminium zinc coating havingGI based corrugated steel sheets 0.50mm thick of any colour as in tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screw complete all as specified and directed by Engr-in-charge.
44M&L for prepration of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed.
45Taking down existingwater proofing treatment from the top of RCC/arch slab, including taking down existing PCC padding tiles mud phuskor plasterand hackingthe topofRCCslab,cleaning with water and disposal of rubbish outside the premises, complete all as specified and directed.
46M&L for PCC type B-1(1:2:4),using 20mm graded crushed stone aggregate as in PCC padding on depression of roof finished even and fair without using extra cement, complete all as specified and directed.
47M&L for WaterproofingtreatmentwithAPP(Atactic Polypropylene)modifiedPolymericmemberaneoverroof consistingofcleaningofconcreteorplastersurfaceofroofand applying evenly a bitumen primer conforming to IS 3488@ 0.30Kg persqmfollowedbyatackcoat@1.2kgperSqmusing85/25 gradeindustrialhotblown bitumenoveritlaid withAPP modified polymericwaterproofingmembraneminimumweight3.6kgper Sqmreinforcedwithnon-wovenpolyesterfabric(weightnotless than 160 gm persqm) unrolled& bondedto substratewith longitudinal and end laps 100mm as per manufacturer"s instruction andapplyingoveritatackcoatusing85/25gradeindustrialhot blown bitumen @ 1.2 kg sqm andas per manufacturer instruction and including taking the APP membrane will be required where the parapet wall exceed 45cm for carrying over and taking into parapet walls,cutoutneatlyahorizontalgroove6.5cmmdeep,7.5cm widesectionwithloweredgeatnotlessthan15cmabovethe gradedroofsurfaceandgrooveshallbefinishedsmoothwith cement mortar 1:4 with WPC @3% by weight of cement where the parapet wall height is 45cm or less no groove will be required as the water proofing treatment will be carried over the top of parapet wall to its full thickness, complete all as specified and directed.
48M&L for 15 mmthickscreedingin cement mortar1:4on roofsurfaceusingwaterproofingcompundaspermanufacturer instructionsurfaces finished even and smoothwithoutusing extra cement asonwallcomplete all as specified and directed.
49M&L for 40 mm thick brick tiles laid on above treated surface and joints grounted flush in cement mortar 1:3 mixed with 5% crude oil by weight of cement on above treated surfacecomplete all as specified and directed.
50All as per item No 48 here-in-before but except brick tiles complete all as specified and directed.
51M&L for PCCtype B-0 1:2:4 (using 12.5mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified & directed.
52Supply only integral water proofing compound(ISI marked), complete all as specified and directed.
53M&Lfor repairing of RCC projections, chajjas , roofs, facia etc. by necessary preparation i.e. scrapping, cutting, chiseling, derusting and cleaning exposed reinforcement, sufaces of damaged, loose RCC surfaces and applying one coat of cement slurry and filling the surfaces with cement concrete (1:1.5:3) using 12.5mm graded crushed stone aggregate and reinforced withwelded mesh of weightexc 2kg per sq mtrbut n.exc 3kg/sqm with or without facia and finished with cement sand mortar (1:3) using coarse sand in patches are n.exc 70mm including applying two coats of finishes to match with the existing surfaces in at any heightcomplete all as specified and directed. Note:- Cost of formwork and welded mesh shall be deemed to be included in unit rate quoted by the contractor.
54S&F in repairs PVC (SWR) pipes, 110mm dia, single socketed, in anylengthwithrubberringjoints,laidintrenchesorinfloors, complete all as specified & directed.
55S&Finrepairs 110mm borePVC(SWR)bends anyradius, complete all as specified and directed.
56Demolitionof stoneor brick masonry built in cement mortar including all quoins, arches etc.but excluding ashlar facing, dressed stone work etc, complete all as specified and directed.
57M&L for brick workwith sub class "B" bricks,straight or curved on planexc 6mmeanradius andbuilt incement mortar 1:6,complete all as specified and directed.
58All as per Srl item No. 56 here-in-before but except bricks.
59M&L for 75mm thick cement concrete 1:3:6, type C1, using 20mm gradedcrushedstoneaggregateasinplinthprotection,laidin slope of 1:20 and surface finished even and smooth without using extracementincludingmakingjointat3mintervalandateach cornerthejointshallbefilledwithbitumenmasticfillingtofull depth (comprising one part hot blown bitumen 85/25 and two part of sand), complete all as specified and directed.
60M&L for Plain cement concrete (1:4:8), type D-2, using 40 mm graded mechanically crushed stone aggregates 75mm thick as in sub base or inmass concrete or in base layer, complete all as specified and directed by Engineer-in-Charge.
61M&L for 25mm thick cement concrete 1:2:4 type B-1, using 20mm graded crushed stone aggregate as in levelling course, surface finished fair and even without using extra cement complete all as specified and directed.
62Taking downcement plasteronbrickorconcrete wallsurfaces etcincludingracking out joints,hackingforkey,scrubbingdown withwateretc. complete all as specified and directed.
63M&L for 10 mmthickrenderingin cement mortar1:3on concretesurfacesofroofprojectionceilingetcincluding repairingofbrokenportionupto6mheightandsurfacefinished evenandsmoothwithoutusingextracement,completeallas specified and directed.
64M&Lfor15mm thick rendering incementmortar 1:6 onfair faces of brick work or concrete surfaces finished even and smoothwithoutusingextracementas on wall completeall as specified and directed.
65M&L for complete removal of existing treatment from wall surfaces and applying one coat of Dr fixit solution to avoid seepage lekage and effect of effloresence, complete all as specified and directed.
66M&Lfor15mm thick rendering incementmortar 1:4on fair facesofbricksurfacesor concretesurfaces,surfacefinished even and fair without using extra cement but usingwater proofing compoundaspermanufacturer"sinstructions,completeallas specified and directed. Note :Water proofing compound shall be measured & paid seprately.
67M&Lforroughcastplasterwithamixtureconsistingofcrushed stone or fine gravel aggregate of size 6 to 8mm as directed, mixed with coarse sand and cement in the ratio 1:1:1, finshed even over rendering with under coat 15mm thick cement and sand mortar 1:4, complete all as specified and directed.
68M&Lforpreparationofnew plasteredorunplasteredsurfacesof ceiling andapplyingthreecoatsofwhitewash,completeallas specified and directed.
69M&Lforpreparationofnew plasteredorunplasteredsurfacesof wallandapplyingtwocoatsofoilemulsiondistemperoverone coatofprimingandover and including1-2 mmthickJK/Birlawallcareputtyto achievesmoothfinishsurface,completeallas specifiedand directed.
70M&Lforapplying two coats of exterior acrylic emulsion (weather proof treatment ), in camouflaging patterns, over new plastered surfaces , including preparation and using primer overnew surfaces ,complete all as specified and directed.
71Dismantlingfloorhearthorwalltilingincludingcementmortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
72M&L for coloured glazed ceramic tiles of approved shade ofsize 450 x 300 mm x 7 to 8mm thick as in vertical surface etc set and jointedinneatcementslurryandpointedinwhiteorcoloured cement to match,laid over and including 10mm thick rendering in cement mortar 1:4,complete all as specified and directed.
73M & L Vitrifiedceramic tiles 10mm thick (Square/rectangular ) polished, area of each tilesnot exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade including 15mm thick screed bed or bedding layer in Cement Mortar (1:6) complete all as specified and directed.
74M&L for non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tilesexceeding 0.11 Sqm butn exc 0.18 Sqm,in flooring etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed in cement mortar 1:6,complete all as specified and directed.
75M&L for Parking floor coloured heavy duty vitrified tiles (Square/rectangular ) polished, area of each tilesexceeding 0.06 Sqm butn exc 0.18 Sqm,set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade including 15mm thick screed bed or bedding layer in Cement Mortar (1:6) complete all as specified and directed.
76Demolition of stone slabs/paver block and tiles of any description or thickness infloors,apronsetc.,laid,beddedandpointedinanymortar, complete all as specified and directed.
77M&Lformachinecutpolishedkotastoneslabflooring18-20mm thickjointedwithgrey cement slurry mixed with pigment to match the shade of the slab,laid over20mmthick screedbedincement mortar1:6, rubbing,grindingandpolishingtoachievemirrorfinish,complete all as specified and directed.
78M&Lforpolishedkota stoneslab 18-20mmthick inriser of steps,skirting,dado andpillarjointed with greycement slurrymixed withpigment to match theshade oftheslab, laidoverandincluding10mmthick renderingincementmortar1:4, rubbing,grinding,roundingof edges andpolishingtoachievemirrorfinish,completeallas specified and directed. Note : Kota stone shall be laid in one pieces for treads and risers for step, window cills and moulding/rounding of edge properly.
79M&L forDholpur stone as on wall cladding with machine cut face work , arches hexagonal roof pillar and all facing etc of15 to 18mm thick one side single length laid andjointed with screw to wall in cement and sand mortar 1:2 including ardelite chemical and recess pointed with an admixture of white cement and dholpur stone dust 1:1 and making edges, work in small patches including preparing the existing wallsurfaces, in any height complete all as specifiedand directed by Engr-in-Charge
80M&L Granite 20 mm thick of any type work(table rubbed and polished) in steps, jambs,pillars windows cill cooking platform and likeincluding pointing in white/colour cement and pigment to match with shade of granite including bull nosing of external, complete all as specified and as directed. complete all as specified and directed.
81Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary on serial page No 17 of tender documents.