Providing Assistance For Operation & Maintenance Of Electrical Installations Ofat Gso Complex, Barc, Tarapur.
BOQ
| Sl. No. | Item Description |
| 1 | Preventive and Breakdown Maintenance :- Preventive and Breakdown Maintenance of of electrical installation of various buildings/structures of GSO, Tarapur such as Sub-station, Adm. Bldg., Accouns section (Works & Salary), Establishment, EMS & AMS Section, HP Lab, L&CM, Inflammable Store, C&M Bldg., Weigh Bridge, Nursery, and Transport Section etc.a)Attending Electrical complaints related to power supply, light, fan power points etc.. of above bldgs.b)Preventive & Breakdown Maintenance of HT & LT panels, electrical equipments of the GSO sub-station such as Transformer, VCB, ACB, battery charger panel, Batteries, Distribution Boards etcWork involves cleaning for dust removal. Checking & tightening of all the connection including Neutral/Earting etc. Replacing lugs, glands, SFU/MCB switches, fuse carrier, fuse base etc. Applying contact grease for fuse gears, joints and terminals etc. c) Operation of HT and LT switchgears for power supply system at GSO complex at plant site, BARC. Attendingpower supply failure complaints and breakdown complaints of M.V. Panels, Motors and starters of water Pump and Bore-well and power failure of 3.3 KV/415 volts, 1000 KVA substation etc. d) Attending faultsof street lights fixed onJ-type pole/garden / 12 M high poles by replacing defective components such as lamps , Ignitor, holders, chokes, capacitors etc. Maint. of Terminal box of these poles by cleaning the box,tightening the connections. Fixing the gland , cleaning and painting the fixing clamp, tightening earthing wire.If required replacing the terminal box etc.e) Operation and maintenance of fire alarm system and other electrical related work as directed by engineer-in-chrage.For the above mentioned work the contract has to depute 3 skilled person per day i.e daily work is to be counted as one operationTotal operations required = 104 week x 5 days in a week = 520 operations .Kindly refer Technical specification for Item description.. |
| 2 | Material handling :-Heavy material handling from Ware House or BARC Plant Site Store up to the work site such as loading the material in the transport given by department and unloading the same at work site and vice versa materials are – cables, of sizes up to300 sq.mm,ceiling fans, lighting fixtures, motors and starters GI pipes and other electrical fittings. For the above mentioned work the contract has to depute at least 4 person (Unskilled) having identity proof such as ration card, election card for security purpose. |
| 3 | Supply & warrantee offollowing items for maintenance as directed by Engineer-in-charge. Lamps |
| 4 | 5-9 watt LED type Lamp |
| 5 | 22-25 watt LEDbatten Aluminium Housing |
| 6 | 12 Watt LED Square surface mounting fittings |
| 7 | 18 Watt PLL LED Lamp |
| 8 | 200 watt LED flood light |
| 9 | 100 watt LED flood light |
| 10 | Supply & warrantee offollowing items for maintenance as directed by Engineer-in-charge. MCBs & RCCBs |
| 11 | 40A , 2 pole RCCB(30 mA) |
| 12 | 63A TPN MCB |
| 13 | 32A TPN MCB |
| 14 | 20A TPN MCB |
| 15 | MCB 2 Pole, 20 Amp. |
| 16 | 6-32A SP MCB |
| 17 | Supply & warrantee offollowing items for maintenance as directed by Engineer-in-charge. Lighting accessories |
| 18 | Starter for 20/40 W tube light. |
| 19 | Supply & warrantee offollowing items for maintenance as directed by Engineer-in-charge. Switches & sockets etc. :- |
| 20 | 6 A , Piano switch |
| 21 | 6 A, 2/3 pin Piano socket |
| 22 | Electronic step Fan regulator |
| 23 | 6/16 Amp. socket with earth pin, 16 A control switch & indicator lamp within a box for mounting on the wall. |
| 24 | PVC insulating tape Red, Yellow, Blue and Black colour, Steel grip |
| 25 | Capacitor 2.5 MFd metal body |
| 26 | Miscellaneous items :- |
| 27 | 2.0 Volt SMF type cell, Type UPST 100Ah |
| 28 | Transformer oil filtration :-Filtration of Transformer Oil of GSO Sub-station transformer up to the required BDV value is obtained.The contractor has to arrange filteration machine for the oil filtration work of transformer of capacity 3.3 KV / 415 V, 1000 KVA, quantity of oil max. 1000 Litres. For the testing the BDV value of transformer oil contractor has to arrange calibrated BDV test machine at the work site. He has to submit the calibration certificate of the machine before BDV testcarried out. The contractor should submit test report ofBDV values obtained. |
| 29 | Overhauling of Ceiling fans, of ceiling fan size 48” Sweep, wall mounting, pedestal and exhaust fans :-Overhauling of Ceiling fans of size 48”/56\" sweep, wall mounting, pedestal and exhaust fans. Work involvesdismantling, replacing the defective parts such as bearing, bush, shaft, capacitors etc., lubricating it and re-assembling the fan, testing for free and noiseless operationand ensure satisfactory performance. spares to be supplied and fitted by the contractor. |
| 30 | Rewinding of Ceilling /Wall mounting /Pedsestal/Exhaust fans of1 phase/3 phase, 50 Hz, 1400 RPM, 1 HP to 5 HP Motor: |
| 31 | Rewinding of Ceiling fan of 48” Sweep 60 to 100 watt including removingold defective winding, cleaning the stator, providing paper insulation, rewinding with super enameled copper wire of required gauge, binding the winding, lead wire connection, provide fiber glass sleeves, varnishing the winding with Dr. Beck golden varnish and drying the motor stator, cleaning the same stator and testing the winding. |
| 32 | Rewinding of Single phase wall mounting fan, pedestal fan and exhaust fan of 100 watts to 500 watts, 230 volts, A.C., 50 Hz., including removing of old defective winding, cleaning the stator, providing the paper insulation, rewinding with super enameled copper wire connection, provide fiber glass sleeves, varnishing the winding with Dr. Beck golden varnish and drying the motor stator, cleaning the same stator and testing the winding. |
| 33 | Rewinding and overhauling ofSingle(1) /Three (3) phase, 50 Hz, 1400 RPM, 1 HP to 5 HP Motor including replacing bearing, gaskets, cable termination etc. |
| 34 | Installation, testing and commissioning of under ground Cable :-Installation, testing and commissioning of 1.1 KV grade, PVC insulated, PVC sheathed, Armoured cable at a depth of 900 mm below the ground level including excavation of trench of size 500 x 900 mm in all types of soils, laying the cable, covering with Baked Bricks and Sea Sand at sides and on top and backfilling the trench and removing the excess earth including taking the cable through sleeve and as directed by Engineer-in-Charge(Elect) . Cable size 10 sq. mmto 300 sq. mm, 4 core or 3 1/2 core. Supply of Bricks and sand is in scope of contractor. (cable will be supplied by department) |
| 35 | Excavation :- |
| 36 | Earth work excavation by mechanical means (Hydraulic excavator) / manual means in all types of soil other than soft and hard rock, dressing the sides of foundation, ramming of bottom etc. including shoring and dewatering (if necessary) and refillingwith selected excavated earth in layers of not more than 500 mm thick, each layer well rammed and consolidated including disposing the surplus earth within a distance of 200 m all as per specifications including clearing Jungle, uprooting of vegetation,grass, etc. complete and as directed by the Engineer-in-charge (a) From 0.00 to 1.50 m depth from Average Ground Level |
| 37 | Excavation in all types of soils with JCB for exposing the cable/jointing/diverting the route etc.for emergency work of cable jointing work or as directed by EIC for excavation. |
| 38 | Cutting of Bituminous Road :-Cutting of Bituminous Road of size 0.6 x 0.9 x 10 M. Repairing the road by concreting with 1:2:4 concrete material up to the level as original one . All materials required for repairing of road such as materials required for Soling, sand, pebbles, Cement, RCC Hume pipes etc. is in scope of contractor. |
| 39 | Maintenance of Water supply pumps :- |
| 40 | Overhauling of 10HP openwellpump motor setof water supply pumps. Removing the defective pump set from the water tank , removing all the connected pipes with nylon rope block and clamps outside the tank, replacing ofbearing, checking impellers, cleaning for free motion, replacing the coupling studs and nuts and painting the set with Anti-corrosive synthetic enamel paint and testing the same for noise free operation & performance and re-assembling the same and its testing for satisfactory performance.etc. |
| 41 | Rewinding of 10HP openwellpump motor set including removing of old defective winding, cleaning the stator, providing paper insulation, rewinding with super enameled copper wire of required gauge, binding the winding, lead wire connection, provide fiber glass sleeves, varnishing the winding with Dr. Beck golden varnish and drying the motor stator, cleaning the same stator and testing the winding. |
| 42 | Maintenance of Borewell Pumps :-There are total 5 No. of Bore wells at BARC Plant site having depth from 70 feet to 150 feet and these bore wells are installed with Submersible bore well pump sets suitable for 6” dia. bores and G.I. Pipes of 2½ dia, Class, ‘C’ , with coupling and bend. In case of replacement of defective pump set, the existing defective pump set has to be removed by dismantling of pipelines and reinstallation of pipelines with replacement of defective pump set after repair. |
| 43 | Dismantling of defective pump set from the distribution line, removing all the connected pipes with Tripod and Chain pully block and clamps upto the depth of pipe line of 150 feet.After re-winding & overhauling , fixing of motor to end pipes and installation of Repaired/ New pump set with the same disconnected pipes with applying Hold tight. |
| 44 | Rewinding: Rewinding of 6.5 H.P. To 7.5 H.P., 3 Phase, 415 Volts, A.C., 50 Hz., 2880 R.P.M. upto 8 stage Submersible Pump motor including supply of all the materials labour charges, transportation etc. |
| 45 | Overhauling of Submersible bore well pump set (motor and pump), 6” dia, of 6.5 H.P. to 7.5 H.P. capacity, 3 phase, 415 Volts, A.C., 50 Hz, 2880 R.P.M. including replacing of bush bearing, thrust bearing, checking impellers, NRV etc. including cleaning for free motion, replacing the coupling studs and nuts and painting the set with Anti-corrosive synthetic enamel paint and testing the same for noise free operation & performance and re-assembling the same. |
| 46 | Locating under ground cable fault by using sensing probe. Set-up for locating the underground cable fault shall be arranged by the agency. |
| 47 | Supply, installation, testing and commissioning of LPG leak detector unit with alarm, Model no.ICR01 of M/s Ceasefire or equivalent as directed/approvedby EIC. |
AI Tender Summary
Tender Timeline
May 08, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedMay 22, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMay 24, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender