Housing Urban and Rular Development Boards / Undertakings / PSU Closing in 0 days TDR #37562072

Tender For Construction Of Ttl Workshop For Upgradation Of Iti At Iti Campus Amritpur Farrukhabad

Issued by Boards / Undertakings / PSU · amritpur, Uttar Pradesh
Tender Value
2.55 Crore
Estimated cost
Bid Submission
16 May 2023
0 days left
EMD
5 Lakhs
Bank guarantee accepted
Document Fee
5310
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
amritpur → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Ttl Workshop For Upgradation Of Iti At Iti Campus Amritpur Farrukhabad

BOQ

Name of Work: Construction of TTL Workshop for Upgradation of ITIat ITI campus, Amritpur Farrukhabad
Sl. No. Item Description
1Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m.(5 fts.) and lead upto 30m.(100 fts.) & including filling. watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-incharges upto a distance of 30 m.(100 fts.) from the foundation trenches.
2Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m to 3.0m and lead upto 30m. & including filling. watering and ramming of excavated earth into the trenches as directed by the Engineer-incharges.
3Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 3.00 m to 4.50m and lead upto 30m. & including filling. watering and ramming of excavated earth into the trenches as directed by the Engineer-incharges.
4Providing and laying Cement concrete 1:4:8 (1 cement : 4coarse sand : 8 graded stone ballast 40 mm nominal size) including supply of all materials.labour and T&P etc. required for proper completion of the work and curing complete. also including cost of formwork in foundation
5Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but including the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impainng strength and durability as per direction of Engineer-in-charge. (Note .-Cement content considered in this item is @ 330 kg/cum Excess/ less cement used as per design mix is payable/recoverable separately). up to plinth level.
6M-150 brick work in 1:4 cement and coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour, and T & P etc.required for proper completion of the work.
7M-150 brick work in 1:6 cement and coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour, and T & P etc.required for proper completion of the work.
815 mm cement plaster on plinth side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand)
9Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at groundfloor only shall be measured as per I.S.6313(PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm(4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm.
10Supply and filling of earth in layers not exceeding 20cm in depth including supply of necessary quantity of earth from a distance not exceeding 8 kms from site of work including watering, ramming and dressing etc complete.
11Sand filling in plinth excluding supply of necessary quantity of sand from a distance not excceding 8 km. (5 miles) from the site of work and including watering, ramming,dressing etc. rate to include cost of all materials, labour and T & P etc. required for proper completion of the work (Labour only).
12M-150 brick work in 1:6 cement and coarse sand of 2.25 coarseness modulus mortar in super-structure. Above plinth level up to floor two level (up to two storey) including necessary cutting and molding of brick work as required and also including honey combed brick work in thickness of wall more than 12cms.
13M-150 brick work in 1:4 cement and coarse sand of 2.25 coarseness modulus mortar in super-structure. Above plinth level up to floor two level (up to two storey) including necessary cutting and molding of brick work as required and also including honey combed brick work in thickness of wall 12cms.
14Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but including the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impainng strength and durability as per direction of Engineer-in-charge. (Note .-Cement content considered in this item is @ 330 kg/cum Excess/ less cement used as per design mix is payable/recoverable separately). Above plinth level up to fifth floor level .
15P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
16Mild steel or ironwork of small sizes and sectionssuch as holding down bolts, hold fasts, tie, rods, grating etc. ( when not includedin an over all rates ) wrought to required form, including supply of steel bolts,nuts and wastage etc and their fixing required for proper completion of the work.(M.S or iron work in hold fasts Door/Window/Ventilator)
17Fixing of Door chaukhats in position.
18Fixing of windows chaukhats in position
19Fixing of ventilators chaukhats in position
2015 mm cement plasterinsingle coat on rough sideofsingle orhalfbrick wall for interior plastering up to floor twolevelincludinginternalrounded angles not exceeding80mm ingirth and finshed even and smooth. 1 cement : 6Course sand
2112mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth. 1 cement : 6 Course sand
22Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor).
23R.C.C. work Providing and laying in position specified grade of reinforced cement concrete in Grid slab , including cost ofform work andexcludingreinforcementin 1:1.5:3 (1 cement : 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size )
24Trimixing of the surface of the cement concrete laid.Including vacuum dewatering, pump,floater machine,double beam screed vibrator.
25Self levelling compound up to 3mm thickness in required area as direction of Engineer in charge.
26Supply & fixing of flexible non directional simpurity range pvc sheet flooring in 2 mm thickness in the size of 2 mtr X 20 mtr use area classification 23/34/43 results from independent testing demonstrate that product inherently inhibits the growth of microbial strain MRSA. It shall be Group-Tandhomogeneous in construction. The flooring shall be specially Diamond 10 coating to give polish free maintenance and manymore timedurability than other vinyl flooring,with total weight of 2.99 kg/m2,dimensional stability X:<0.4%;Y:<0.4%, Flexibility-no cracking, static electrical charge <2kv,good resistant to chemical & scratch, slip-R9, fire-Bf1-s1 ,& doesnot favor in growth fungi & bacteria,duly installed on smooth and hard surfacewith company recommended adhesive.Make Armstrong .
27Supply and fixing of anodized aluminium door having 2mm thick aluminium section excluding coating and average coating of 20 microns fully glazed made of aluminium door tube size 83.5x44.65 mm as vertical member and 1140x44.45mm size tube in bottom and horizontal member door chaukhat should be of aluminium tublar vertical with two openable shutter, the rate will include cost of material ficture 4mm thick glass handles locks screw necessary bending and excluding cost of floor spring if required for proper completion of work as per direction of Engineer-In-charge. BUT FOR FIXED GLAZING
28Supply and fixing of anodized aluminium door having 2mm thick aluminium section excluding coating and average coating of 20 microns fully glazed made of aluminium door tube size 83.5x44.65 mm as vertical member and 1140x44.45mm size tube in bottom and horizontal member door chaukhat should be of aluminium tublar vertical with two openable shutter, the rate will include cost of material ficture 5mm thick glass handles locks screw necessary bending and excluding cost of floor spring if required for proper completion of work as per direction of Engineer-In-charge.
29Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately)Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm).
30Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete asper the direction of Engineer-in-charge.With stainless steel cover plate minimum 1.25 mmthickness
31Supply of fixing 6 mm (1/4\") thick ceramic glazed tile in flooring or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement jointed and polishing complete including supply of all materials, labour for proper completion of the work.For floor and wall
32Providing and fixing of flush door shutters commercial quality conforming to IS : 2202 Part I (1983) including fixing fixing of wooden cleats & stoppers and including fixing and adjustment of hinges, bolts locks, handles, springs and other fittings but excluding their supply and including painting with two coats of black Japan paint on all iron fitting if necessary. Fitting with necessary screws to be supplied departmentally.35 mm thick.single leaf
33Providing and fixing of flush door shutters commercial quality conforming to IS : 2202 Part I (1983) including fixing fixing of wooden cleats & stoppers and including fixing and adjustment of hinges, bolts locks, handles, springs and other fittings but excluding their supply and including painting with two coats of black Japan paint on all iron fitting if necessary. Fitting with necessary screws to be supplied departmentally.35 mm thick For Double Leaf
34Providing & fixing stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm
35P/Fixing stainless steel tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as / IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. 300 mm x 10mm
36Providing & fixing stainless steel handles ISI marked anodised ( anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 125 mm
37Wall painting with plastic emulsion paint of approved brand and manufacture on decorative wall surface to give an even shade including throughly brushing the surface clean all dirt ,grease loose piece and prepare smooth.
38Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications : 13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
39Providing wall putty on New surface with approvel quality material of Berger/J.K./Birla or similar make 2 coats.
40Painting or vanishing two coats on iron works in small areas or new wood work with one coat of ready mixed priming paint & one coat of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials labour and T & P etc. required for proper completion of work.Paint to be used should confirm to the I.S.I No.103 1950
41Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
42Making grooves 10 to 12mmwide xam deep in plaster of the walls or in ceiling vertically or horizontally as required.
43Providing and fixing glass strips in joints of floors and skirting or dado add the time of laying floors flush with floor level including supply of all materials, labour T & P etc. required for proper completion of the work. 3.15mm thick and 3.70 cm depth
44Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
45Factory Finished peb Structure compring of built up columns built up truss frame, manufactured out of 345 Mpa hi-tensile steel of approved make JSW/ESSAR/ISPAT LTD All Structural members shall be designed as per IS only Flange to web continuous welding will be done by submerged process arc process and rest joints will be done MIG welding process and shall be in accordance with AWS D 1.1 and D 1.3 as applicable.All welders shall be qualified and certfiled and certified for type of welds performed. Member shall be fabricated shall be kept minimum and given factory applied alkyd base DTM mono coat Paints System minimum 90-110 micron of approved make(Akzonabal, Asian Plaint, Berger) All Strcuctual member shall be disigned as per IS For built-up IS 800:2007 Limit state design and wind load as per IS 875 part 3, 2015 and for sismic IS 1893 (part-1)-2016 All cold form (If Required) purlin (if Required) Shall be manufactured out of 345 MPA and In depth of 200/230/250 mm as per approved GA Drawng. All cold form members (Side girt/Roof purlin) Shall be made of Hi-tensile Steel (Z-275Gsm Zinc Coated/345Mpa Confirming to ASTM-8653. All hot rolled secondary members like bracing angies conncection plates etc shall conform to IS:2062 with minimum yield strength of 250 Mpa. All bracing members shall be hot rolled rod or angle bracing as per final approved design and drawings the other component such as clips connection plates portal bracing anchor bolt etc shall be offered in MS Steel grade 245mpa be bolted connection. All Strcutural connection will be electroplated with 8-10 microns coating on high strength bolts conforming to IS 1364 ir ASTN A325, grade. 8.8. Minimum bolt size shal be 12mm diameter or as specified in approved drawing. All hot rolled Secondary members like bracing angines, connection plates etc shall conform to IS 2062 with minimum yield strength of 250 Mpa all bracing members be hot rolled angles. Anchor bolt(Black steel) Shall conform to ASTM F1554 grade 36 with minimum yield strenght of 245 Mpa. Nuts and lock nuts shall conform to IS 1363(Part 1 to 3)/ASTM A 563/ASTM A563M and Only plate washer will be used as per IS 2062 or ASTM A572. All anchor bolts shall have lock nuts. Anchor Bolts shall be designed considering concrete strenght. The Portion of anchor bolts project above concrete (inclusive of the part within grout) shall be mechanically cleaned and painted as per soec after erection. Anchor bolts shall not be less than 15-20mm of diameter. Total number of anchor bolts shall not be less than foru in any base plate. Rod or Pipe bracing is considerd on Roof as per approved GA. For roof and wall cladding self-drilling screws shall confirm to AS-3566 Standard.
46Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 micronsepoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
47Thermal Insulation of roofing with Expanded polystyrene fixed with suitable adhesive to the false ceiling as per the directions of the Engineer-in-charge: 12.36.1 With Type N - Normal 50 mm thick
48Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.
49Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. 0.80 mm thick with zinc coating not less than 275 gm/m²
50Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size 24x32 mmof length 600mm to formgrid module of size 600 x 600 mm, suspended from ceiling usinggalvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The workshall be carried out as per specifications, drawing and as per directionsof the Engineer-in- Charge. 26.22.1 With 15 mm thick Tegular edged light weight calcium sliciate false ceiling tiles
51Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.10.6.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover
52Providing and fixing ball bearing for rolling shutters.
53Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required a)White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests brand perryware cera or equivalent .
54Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, Parryware/ Hindware/ Cera with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked black solid plastic seat and lid
55Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
56Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 32 mm dia
57Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 40 mm dia
58Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers.
59Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete,including painting of fittings and brackets, cutting and making good the wall wherever required : Size 450x300x150 mm
60Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms.
61Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms
62Providing and Fixing C.P. brass Ablution health faucet assembly with 1.2 m long braided PVC hose with mounting bracket fixed on wall complete.[FOR EWC]
63Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 90mm
64Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 110 mm bend
65Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of approved quality conforming to15 mm nominal bore
66Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 110 mm diameter
67Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm
68Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge Concealed work including cutting chases and making good the walls etc.(a) 20mm dia nominal outer dia pipes
69Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Exposed on wall(b) 25mm dia nominal outer dia pipes
70Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 15 mm nominal bore
71Providing & fixing CP brass bib cock of approved quality conforming to IS 893115 mm nominal bore
72Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
73Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 893115 mm nominal bore
74Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank. [Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].Capcity in Per Liters
75Providing and fixing brass stop cock of approved quality. 20 mm nominal bore
76Supply and fixing of UPVC SWR Pipe type B confirming to IS 13592 Including jointing the pipes with rubber ring lubricant and UPVC SWR cuplar confirming to IS 14735 Also includinhg excavation of trenches cutting of walls,floor and refilling the trenches as before ,but excluding supply and cost of other fitting such as elbow ,bend,tee and y-tee including supply of all materiallabour and T & P .required for proper completion of work. a) 160 mm diameter
77Supply and fixing of UPVC SWR Pipe type B confirming to IS 13592 Including jointing the pipes with rubber ring lubricant and UPVC SWR cuplar confirming to IS 14735 Also includinhg excavation of trenches cutting of walls,floor and refilling the trenches as before ,but excluding supply and cost of other fitting such as elbow ,bend,tee and y-tee including supply of all materiallabour and T & P .required for proper completion of work. 200 mm diameter
78Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround UPVC S.W.R Pipes including bed concrete as per standard design. a) 160 mm diameterS.W. Pipe
79Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) up to haunches UPVC S.W.R Pipes including bed concrete as per standard design. 160 mm diameterS.W. Pipe
80Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) up to haunches UPVC S.W.R Pipes including bed concrete as per standard design. 200 mm diameterS.W. Pipe
81Providing and fixing square mouth UPVC S.W.R Gully trap grade \"A\" complete with C.I. grating brick masonry chamber with F.P.S. bricks of class designation 75 and water tight C.I. cover with frame of 300 x 300mm.size (inside) the weight of cover to be notless than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design. a) 150 x 100 mm. size P type
82Constructing brick masonry INSPECTION chamber 500x700x600 mm with bricks of class designation 150 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as perdesign. With FPS bricks
8315 mm cement plaster inside of septic tank of mix 1: 4(1 cement : 4 coarse sand) with a floating coat of neat cement of mix
84Making Soak pit 1.25m diameter 2.5 mt depth including excavation disposal of surplus earth refilling it with coarse aggregateand RCC slab on top 1 :2 :4 with 450mm dia manhole cover and frame complete as required as per the standard design.
85Providing & fixing 75 mm dia vent pipes.
86Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar
87Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter
88Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole manually.
89Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia
90Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
91Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
92Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.
93Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge.
94Providing and laying cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size ) and curing complete including cost of form work.
95Providing and laying in position bitumen hot sealing compound for expansion joints etc.Using grade \"A\" sealing compound.
96Wiring point for light with 1.5 Sq. mm FR PVC insulated multistrandsinglecorecopperconductorcableinPVCconduit with 1.5 Sq. mm FRLSH PVC insuleted multistrand copper conductorcableasearthwiredrawninside.continuitywire, Modular type switch & ceiling rose/angle/batten holderon 3mm thickphenoliclaminatedbackelitesheetetc.completeinall respect. with Modular Box & Cover plate.
97Wiring point for two way light with 1.5 Sq. mm F.R. PVC insulated multistrandsinglecorecopperconductorcableinPVCconduit Pipewith1.5SqmmFRLSHPVCinsuletedmultistrandcopper conductorcableasearthwiredrawninsidetheconduit.Modular typeswitches&ceilingrose/angle/battenholderon3mmthick phenoliclaminatedbackelitesheetetc.completeinallrespect. with Modular Box & Cover plate.
98Wiring point for fan/fresh air fan (light duty exhaust fan) with 1.5 Sq.mmFRLSHPVCinsulatedmultistrandsinglecorecopper conductorcableinPVCconduitwith1.5Sq.mmFRLSHPVC insuleted multistrand copper conductor cable as earthwire drawn inside the conduit, Modular type switch & ceiling rose on 3 mm. thick backelite sheet etc. complete in all respect with Modular Box & Cover plate.
99Wiringpointforplug with1.5Sq.mmFRLSHPVCinsulated multistrandsinglecorecopperconductorcableinPVCconduit with 1.5 Sq. mm FRLSH PVC insuleted multistrand copper conductorcableasearthwiredrawninsidetheconduit,Modular type switch & socket etc. complete in all respect with Modular Box & Cover plate.
100Supply and wiring ofsubmain 2 number 4 sqmm. FRLSH PVC insulated 1100 V grade multistranded single core copper conductorcableinheavyduty(2mmthick)20mmdiaPVC conduit partly concealed in wall and partly laid in slab along with onenumber2.5sqmm FRLSHPVCinsulatedmultistranded copper conductor. cable as earth contunity wire etc. complete in all respects. .
101Supply and wiring ofsubmain 2 number 6 sqmm. FRLSH PVC insulated 1100 V grade multistranded single core copper conductorcableinheavyduty(2mmthick)25mmdiaPVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FRLSH PVC insulated multistranded copper conductorcableasearthcontunitywireetc.completeinall respects.
102Supply and wiring of submain 4 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductorcableinheavyduty(2mmthick)32mmdiaPVC conduitalong with two numbers 6 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
103Supply and wiring of submain 4 number 16 sqmm . PVC insulated 1100Vgradesinglecorecopperconductorcablein40mmdia PVC conduitalong with two numbers 10 sqmmsingle core PVC insulated copperconductor cableasearthcontunitywireetc. complete in all respects.
104Erectionand testingofceilingfan andregulator forroomheight upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects.
105Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 185 sqmm 3.5 core
106Supply fixing of electronicfanregulator(modular)120-280V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work.
107Supply and Fixing of Ceiling fan with fan motor of AC permanent insulation, capacitor rating conforming BEE 5 star rating and IS: 374/79andalsocomplywithIS:1709/1984withlatest amendment.Theratedvoltage220/240volt50Hz,1-phACthe fan assemble should consist of down rod blades, shackle canopiesetcandwithdoubleballbreaingsystemBEE5star rated-1200 mm sweep.
108Supply & fixingofLEDTubeLightwith battensuitableforupto 1X22W LEDtube light Fittingincluding tubeon surface complete in all respects.(CAT: AAA)
109Supply&Fixing ofSingleWallBracketonMatchingMDFEG Board base etc. complete in all respect.Cat. AAA
110S & F surface/Flush mounting 4ways TPN distribution board with additionalmetaldoorwithoutMCBcompleteinallrespect,as directed at site by Engineer in charge. CAT A
111S&Fsurface/flushmounting6waysVTPNdistributionboard without additional metal door without MCB complete in all respect, as directed at site by Engineer in charge.CAT A
112S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve
113S&Fof40Amp.4poleFP MCB(10KA)
114Supply and fixing of power plug with 20 Amp./250 volt flush type modularswitchand5pin20A/250voltflushtypeuniversal modular socket switch on concealed M.S box including supply of allmaterial,labourT&Petc.requiredforpropercompletionof work.
115Supply and fixing sheet steel enclosure surface / flush mounting fitted with 20 Amp 2 Pin and earth metal clad scraping earth plug andsocketcompleteinallrespectasdirectedatthesiteby Engineer in charge.
116SupplyandburryingofSafeEarthingElectrodeT-19,(HotDip Galvanized), Length up to 3000mm, outer Pipe 76mmInner Dia 38 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductiveproperty with50kgsactivatedsoil(BFC)capableof reducing the soil resistivity with good mixture of retaining capacity andoneearthingleadof25mmx3mmG.I.strip,uptoswitch board(fromaprontoswitchboard,thecostofG.I.stripwillbe extra)alongwith30cmsquareC.I.framewithhingedcover& masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.
117Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respects.
118Supply and fixing of one number 8 SWG G.I wire in 15mm dia. G.I pipe for earthing laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for propercompletionoftheworkasdirectedatsite.
119Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mmbelowgroundleveloveracushionof75mmthicksand alroundandprotectedwithburntbricksonsidesandtopon surface,thecablerunshallbefixedonM.S.clampsetc.of suitable size. As per50 sqmm3.5 core(k)
120Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring ofthecableshallbeproperlyconnectedwiththeearthasper direction of E/I. As per PWD SOR-2018 S.I. No.-503 50 sqmm3.5 core(k)
121SupplyandfixingofPalm/pintypecoppertinplatedcables sockets(lugs)tothecableleads,insuslatingwithtapeand makingofconnectionsetc.completeinallrespects asper direction of Engineer-Incharge. 50 Sq.mm (f)
122Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.0mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires andadequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCB\"s to be used. All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm Main L.T. Panel Incoming : One (1) No 320 Amp. 4 pole MCCB of 50 KABreaking capacity Metering : One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. One (1) No. (0-320A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. One (1) Set of Phase Indication Lamp. Bus Bar : One (1) No. 400 A, TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on each outgoing to be provided. 125 Amps TP MCCB of 25 KA (Ics=Icu) Breaking Capacity- 2 No. 40 Amps TP MCB of 10 KA (Ics=Icu) Breaking Capacity- 4 Nos. 125 Amps TP MCCB of 25 KA (Ics=Icu) Breaking Capacity- 1 No. Spare 40 Amps TP MCB of 10 KA (Ics=Icu) Breaking Capacity- 1 No. Spare
123SUB-PANEL 1 & 2Incoming : One (1) No 125 Amp. 4 pole MCCB of 36 KABreaking capacity Metering : One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. One (1) No. (0-125A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. One (1) Set of Phase Indication Lamp. Bus Bar : One (1) No. 200 A, TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on each outgoing to be provided. 40 Amps TP MCB of 10 KA (Ics=Icu) Breaking Capacity- 4 Nos. 63 Amps TP MCB of 10 KA (Ics=Icu) Breaking Capacity- 1 No. Spare 40 Amps TP MCB of 10 KA (Ics=Icu) Breaking Capacity- 1 No. Spare
124Providing & fixing of 3 Pin telephone outlet complete in all respect on existing board with connections as required.
125Providing, drawing, connecting and testing of telephone / Networking wire 2 pair 0.51 sqmm. tinned copper conductor PVC insulated in existing conduit from telephone / Computer outlet box to the junction box/tag block.
126Providing and fixing connecting and testing of telephone tag block in MS box with hinged and lockable cover duly painted over primer as required.10 Pair
127Providing and Laying unplastisized rigid PVC pipe conforming to IS:13592 type A including jointing , cuttingand making good the walls & floors as per requirement. 150mm
128Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required300mm sweep.
129Supply & fixing of 36 Watt to 46 Watt indoor recess mounting LED Square Fitting for Aramstrong Ceiling having powder coated die castealuminium housing with body with extended heat sink and diffuser of special polycorbonate material and driver set complete in all respect.CAT-AAA .
130Supply & fixing ofFactory wired inegaral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 40 to 50 watt confirming to IP 65 protection complete.CAT-AAA .
131Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
132Supply & fixing of CO2 type fire extinguisher,6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
133Supply of Air conditioner of 1.5 Tone capacity with remote with 1.5 m .copper flexible main cable single phase copper cooling coil . make blue star ,Voltas,carrier,LG.Including Instalation & testing and commiosing charge of split air conditioner & fixing of MSstand for outdoor unit of AC.Supply of 3 core cable for connecting indoor to outdoor unit Complete in all respect.
134Supply of Air conditioner of 2 Tone capacity with remote with 1.5 m .copper flexible main cable single phase copper cooling coil. make blue star ,Voltas,carrier, LG .Including Instalation & testing and commiosing charge of split air conditioner & fixing of MSstand for outdoor unit of AC.Supply of 3 core cable for connecting indoor to outdoor unit Complete in all respect.

AI Tender Summary

OUR REF NO 37562072
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 2.55 Crore
LAST DATE 16-05-2023
Authority
Authority Name Uttar Pradesh Housing And Development Board
Work Description Construction Of Ttl Workshop For Upgradation Of Iti At Iti Campus Amritpur Farrukhabad
Basic Detail
Tender No 398/S-1/16 Date 05.04.2023
Bidding Type Tender
Location
City amritpur
State Uttar Pradesh
Key Dates
Publish Date 06 May 2023
Submission Date 16 May 2023
Open Date 16 May 2023
Finance
Tender Value 2.55 Crore
Tender Fee 5310
EMD 5 Lakhs
Exemption Not Available
Document List
e7e71944-7a99-4db6-bbff-5e4109f47a0d.html
BOQ_1339164.xls
financialbid.pdf
technicalbid.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 06, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
May 16, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 16, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

e7e71944-7a99-4db6-bbff-5e4109f47a0d.html

xls

BOQ_1339164.xls

pdf

financialbid.pdf

pdf

technicalbid.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender