Uttarakhand Power Corporation Limited-UPCL has published Tender For Repairing Of Electricity Lines. Submission Date for this Tender is 01-06-2023. Transmission Line Tenders in almora Uttarakhand. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Supply of Top Channel Clamp SP23 with N&B |
2 | Supply of Suspension clamp for 11 KV XLPE Cable |
3 | Supply of J hook for 11 KV XLPE cable |
4 | Supply of LT Shackle Insulator with N&B |
5 | Supply of LT Clamp for SP-21 with N&B |
6 | Motarable cartage of Material from Almora to road side dump store Including Loading & Un-loading both End.Dist 30 KmST pole SP 23 (Galvenised) |
7 | Motarable cartage of Material from Almora to road side dump store Including Loading & Un-loading both End.Dist 30 Km ST pole SP 21 (bottomPortion hot Dip) |
8 | Motarable cartage of Material from Almora to road side dump store Including Loading & Un-loading both End.Dist 30 Km 11/0.4 KV 100 KVA New |
9 | Motarable cartage of Material from Almora to road side dump store Including Loading & Un-loading both End.Dist 30 Km 11/0.4 KV 63 KVA New |
10 | Motarable cartage of Material from Almora to road side dump store Including Loading & Un-loading both End.Dist 30 Km Small materials |
11 | Head load cartage of following materials from Dump store to pit site ava. Lead distance 3 Km ST pole SP 23(Galvenised) |
12 | Head load cartage of following materials from Dump store to pit site ava. Lead distance 3 Km ST pole SP 21(Galvenised) |
13 | Head load cartage of following materials from Dump store to pit site ava. Lead distance 3 Km 11/0.4 KV 100 KVA New (Upto 1Km) |
14 | Head load cartage of following materials from Dump store to pit site ava. Lead distance 3 Km 11/0.4 KV 63 KVA New (upto 0 to 1 Km) |
15 | Head load cartage of following materials from Dump store to pit site ava. Lead distance 3 Km Small materials (upto 1 to 3 Km) |
16 | Dismentling of Existing LT/HT line including Disc Fitting, Insulator, clamp, Nut bolt Etc. Including rolling of conductorSingle Pole SP 21 |
17 | Dismentling of Existing LT/HT line including Disc Fitting, Insulator, clamp, Nut bolt Etc. Including rolling of conductorSingle Pole SP 23 |
18 | Dismentling of Existing LT/HT line including Disc Fitting, Insulator, clamp, Nut bolt Etc. Including rolling of conductor11 KV ACSR weasel |
19 | Dismentling of Existing LT/HT line including Disc Fitting, Insulator, clamp, Nut bolt Etc. Including rolling of conductor11 KV XLPE Cable 3x70 sqmm |
20 | Dismentling of Existing LT/HT line including Disc Fitting, Insulator, clamp, Nut bolt Etc. Including rolling of conductorLT 3 PH 4 wire Weasel / AB cable |
21 | Dismentling of Existing LT/HT line including Disc Fitting, Insulator, clamp, Nut bolt Etc. Including rolling of conductor11/0.4 KV 100 KVA New |
22 | Dismentling of Existing LT/HT line including Disc Fitting, Insulator, clamp, Nut bolt Etc. Including rolling of conductor11/0.4 KV 63 KVA New |
23 | Excavation of earth for pole pit for errection of pole in all type of soil in size 0.9X0.6X1/6X8.5 Mtr Sp 23/21/10 pole |
24 | Erection of Single Poles support in proper level and alignment alongwith Fixing all Accessories in the pole as per RESPO of SP-23. |
25 | Erection of Single Poles support in proper level and alignment alongwith Fixing all Accessories in the pole as per RESPO of SP-21/10 |
26 | Grouting of pole in size 0.45x0.45x1/9 of the support in cc ratio 1;4:8 block including cost of cement, sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESPO construction manual (mid span new pole) ST Pole SP-23/21/10(0.178) |
27 | Muffing of poles size 0.45x0.60 cm radious with cc 1:3:6 block size 45 cm height from ground level including cost of cement, stone and sand etc. |
28 | Excavation of foundation pit for Erection of retaing wall support for Sp 33 size 5X3X1 CuMas per RESPO in ratio of 1:4:8 CC Including cost of Blast, cement & sands etc. as per RESPO |
29 | Fixing of 11 KV Cable J/Kit |
30 | Laying & Resagging of 11 KV line XLPE Cable 3x70 sqmm |
31 | Laying & Resagging of 11 KV line in Weasel Conductor Complete including Fixing of all accessories as per RESPO (1ph or 3 Ph) |
32 | Laying & Resagging of LTLine with ACSR Weasel conductor including continuous earth wire complete work up to energizing LT 3 PH 4 wire Weasel / AB cable |
33 | Installation/mounting of new T/F in DP structure and its complete comissioning as per RESPO 11/0.4 KV 100 KVA New |
34 | Installation/mounting of new T/F in DP structure and its complete comissioning as per RESPO 11/0.4 KV 63 KVA New |
35 | Back Head load cartage of materials from pit site to Dump store ava. Lead distance 3 Km 11/0.4 KV 100 KVA New (Upto 1 Km) |
36 | Back Head load cartage of materials from pit site to Dump store ava. Lead distance 3 Km 11/0.4 KV 63 KVA New (upto 1 Km) |
37 | Back Motarable cartage of Material from road side dump store to Almora Including Loading & Un-loading both End.Dist 65 Km 11/0.4 KV 100 KVA New |
38 | Back Motarable cartage of Material from road side dump store to Almora Including Loading & Un-loading both End.Dist 65 Km 11/0.4 KV 63 KVA New |
39 | Back Motarable cartage of Material from road side dump store to Almora Including Loading & Un-loading both End.Dist 65 Km Small materials |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy