Tender For Annual Maintenance Of Different L.I Schemes Under Pecharthal R.D. Block Under Water Resource Sub-Division, Kanchanpur, North Tripura During The Year 2023-2024 / Sh:- Providing Starter, Panel Board And Mechanical Accessories And Repairing Of Suc
Tender Overview
Project Description
Annual Maintenance Of Different L.I Schemes Under Pecharthal R.D. Block Under Water Resource Sub-Division, Kanchanpur, North Tripura During The Year 2023-2024 / Sh:- Providing Starter, Panel Board And Mechanical Accessories And Repairing Of Suction Delivery Line
BOQ
| Sl. No. | Item Description |
| 1 | Dismantaling of pump for over hauling including greasing, gland packing, necessary repairs & reinstallation of the same including trial run for 10 hrs. in two spell complete as per direction of the Engineer-in-Charge. |
| 2 | Providing & fitting fixing C.I coupling complete with nuts & bolts of approved quality.a) 150 mm f |
| 3 | Providing & fitting fixing coupling nuts & bolts (all Size)of approvedquality. |
| 4 | Providing & fitting fixing coupling rubber bush (All Size)of approved quality. |
| 5 | Providing & fitting fixing coupling star bush (All Size) of approvedquality. |
| 6 | Providing & fitting fixing Pump Shaft of approved quality. |
| 7 | Providing & fitting fixing Shaft sleeve of approved quality.a) Cast iron (CI) |
| 8 | Providing & fitting fixing Shaft sleeve nut of approved quality.a) Cast Iron (CI) |
| 9 | Providing & fitting fixing Casing ring of approved quality. |
| 10 | Providing & fitting fixing C.I. gland of approved quality. |
| 11 | Providing & fitting fixing Nuts & bolts full threaded 10mm dia and 100 mm long (Stag nut) for gland of approved quality. |
| 12 | Providing & fitting fixing Lantern Ring for pump of approved quality. |
| 13 | Repairing of star-delta starter in/cl.supplying of flanger nuts, bolts, magnet coil as per direction of the Engineer-in-charge. |
| 14 | Repairing of pump shaft by welding, polishing etc. complete as per direction of the Engineer-in-charge. |
| 15 | Providing & fitting fixing C.I. Impeller of approved quality for Horizontal pump. |
| 16 | Supplying & fitting fixing manually operated oil immerged starter of approved quality.a) 30 Hp Osco/BCH Make |
| 17 | Supply & fitting fixing ball bearing of approved quality for pump required during overhauling.a) 6305 Ball bearing (TATA /SKF) |
| 18 | b) 6306 Ball bearing (TATA /SKF) |
| 19 | Supply & fitting fixing ball bearing of approved quality (TATA/SKF MAKE) for motor.a) 6308 Ball bearing (TATA /SKF) |
| 20 | b) 6309 Ball bearing (TATA /SKF) |
| 21 | c) 6310 Ball bearing (TATA /SKF) |
| 22 | Supplying & fitting fixing of GI . bend of approved quality.a) 125 mm dia |
| 23 | b) 150 mm dia |
| 24 | Providing & fitting fixing 20/25 HP motor fan of approved quality at site of work. |
| 25 | Provinding & fitting fixing of Amp-meter, voltmeter selector switch of approved quality. |
| 26 | Providing & fitting fixing M.S flange (10mm thick) at site of work of approved quality.a) 150 mm dia |
| 27 | b) 125 mm dia |
| 28 | Providing & fitting fixing Rubber flange washer 6 mm thick at site of work of approved quality.a) 150 mm dia |
| 29 | b) 125 mm dia |
| 30 | Providing & fitting fixing MS hose clamp with nuts & bolts etc. complete at site of work of approved quality.a) 150 mm dia |
| 31 | Providing & fitting fixing PVC suction hose pipe overall thickness 5mm of best quality at site of work (Pankaj made) of approved quality.a) 150 mm dia |
| 32 | Provinding & fitting fixing C.I. non- return valve of approved quality as perCPWD specification and direction of the Engineer-in-charge. A) 150 mm dia. |
| 33 | Providing & fitting fixing C.I tail piece of approved quality at site of work.a) 150 mm dia |
| 34 | Labour charges for flange welding with GI pipe by electric plant. |
| 35 | Providing & fitting fixing C.I foot valve of heavy duty at site of work of approved quality.a) 150 mm dia |
| 36 | Providing & fitting fixing C.I foot valve weight 150mm dia at site of work of approved quality. |
| 37 | Providing & fitting fixing C.I foot valve ring 150mm dia at site of work of approved quality. |
| 38 | Providing & fitting fixing C.I foot valve net 150mm dia at site of work of approved quality. |
| 39 | Dismantalling of motor for varnishing, heating etc. complete in/c reinstallation and trial run for 10 hrs in two spell complete as per direction of Engineer-in-charge. |
| 40 | Providing & fixingof GI pipe of Heavy class as perIs: 1239 with latest amedment complete with G.I fittings including trenches and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer-in-charge.A) 40 mm dia. (for primimg line). |
| 41 | B) 50 mm dia. (for primimg line) |
| 42 | Labour charge for laying of G.I pipe conforming IS 1161,3589 & 1239 including fitting fixing complete as per direction of Engineer-in-Charge.a) 150 mm dia nominal bore(medium) |
| 43 | b) 125 mm dia nominal bore(medium) |
| 44 | Labour charge for fitting fixing of CI sluice valve class-I with cap complete by providing nuts and bolts, 3mm thick rubber insertion etc.(Tail piece if required will be paid separately) (only C.I sluice valve class-I with will be supplied by deptt. at free of cost) a) 150 mm dia. |
| 45 | b) 125 mm dia. |
| 46 | Supplying & fitting fixing of Terminal plate for 20/25 HP horizontal motor. |
| 47 | Providing and fixing G.I. Full way valve as per CPWD specification and direction of the Engineer - in - charge.40 mm dia |
| 48 | Providing and fixing of Brass Union Joints (Medium class) with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in -charge.40 mm dia |
| 49 | Providing and fixing G.I. socket as per CPWD specification and direction of the Engineer - in - charge.40 mm dia |
| 50 | Supplying & fitting fixing of rubber flange washer 6mm thick of approved quality as per direction of the Engineer-in-charge.a) 125 mm dia |
| 51 | Repair to shore manifold after dismantling the same from the alignment by providing MS sheet in lower portion with welding touches with C.I. stick at workshop & re-fitting the same at site of workas per direction of the Engineer-in-charge. |
| 52 | Providing and fitting fixing of M.S shore manifold made with 3mm thick MS sheet of size one way 315 mm dia & three way 125 mm dia made with suitable flange(all end) including coating with sheet primer (tailpiece if required will be paid separately ) including proper alignment with pipe line & earth cutting ,backfilling complete as per direction of Engineer-in-charge. |
| 53 | Providing & fixing 200 Amps busbar of size 600X 450X100 mm with 4 nos. copper strip of size 450X40X4 mm of approved quality. |
| 54 | Supplying & fitting fixing of 7/16 Copper Wire with all electrical equipments including trial run etc. complete (ISI Marked) on the pannel board of approved quality. |
| 55 | Supplying and fitting fixing of selector switch on the panel board of approved quality. |
| 56 | Providing & fitting fixing Steel sheet enclosed switch Fuse unit ( Suitable for DIN fuse) triple pole with Neutral Link (TPN) , 415/500 Volt, complete as per direction of Engineer-in Charge. A) Current range 63 Amps. |
| 57 | B) Current range 200 Amps. |
| 58 | Providing & fitting fixing of foot valve washer 200 mm dia of best quality as per direction of Engineer-in charge. |
| 59 | Repairing of 200 Amps Main switchproviding all Kit-Kat & kit kat base & repair where necessary fitting fixing & testing in/cl. Supplying necessary kit-cuts. |
| 60 | Repairing of 63 Amps Main switchproviding all Kit-Kat & kit kat base & repair where necessary fitting fixing & testing in/cl. Supplying necessary kit-cuts. |
| 61 | Supplying & fitting fixing of 63 Amps kit cut for main & sub-main switch (Male & female) |
| 62 | Supplying & fitting fixing of 200 Amps kit cut for main & sub-main switch (Male & female) |
| 63 | Providing & fixingC.I. sluice valve (with CAP)complete with bolts, nuts, rubber indertions etc. (the tail piece if required will be paid separetely) as per CPWD specification and direction of the Engineer-in-charge.a)125mm dia PN-1. |
| 64 | b)150mm diaPN-1. |
| 65 | Supplying and greasing/applying of grease in wheel bearing complete as per direction of Engineer-in-charge. |
| 66 | Supplying and fitting fixing of asbestos rope of best quality as per direciton of Engineer-in-charge. |
| 67 | Hiring charge of welding set of single phase with operating staff and carrying upto the site of work including loading and unloading (both way) complete as per direction of Engineer-incharge. |
| 68 | Providing and fixing G.I. pipes of Heavy class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in -charge.A. External work. i) 125 mm dia. nominal bore |
| 69 | ii) 150 mm dia. nominal bore |
| 70 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.-All kinds of soil |
| 71 | Providing & fitting fixing sleeve bush (brass) for HPLI pump of best quality as per direction of Engineer-in-charge. |
| 72 | Providing & fitting fixing gland for HPLI pump of best quality as per direction of Engineer-in-charge. |
| 73 | Providing & fitting fixing gland nut(16mm dia) for HPLI pump of best quality as per direction of Engineer-in-charge. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender