Tender For Repair/Maintenance Of Air Conditioner, Deep Freezer, Voltage Stabilizer And Repair To Summer Appliances Water Cooler,Refrigerator And Its Connected Items At Af Stn Purnea Under Ge (Af) Purnea., purnea-Bihar

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Air Conditioner, Deep Freezer, Voltage Stabilizer And Repair To Summer Appliances Water Cooler,Refrigerator And Its Connected Items At Af Stn Purnea Under Ge (Af) Purnea.. Submission Date for this Tender is 06-06-2023. Voltage Stabiliser Tenders in purnea Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

37533558
Corrigendum : Tender For Repair/Maintenance Of Air Conditioner, Deep Freezer, Voltage Stabilizer And Repair To Summer Appliances Water Cooler,Refrigerator And Its Connected Items At Af Stn Purnea Under Ge (Af) Purnea.
Open Tender
Indian
Bihar
purnea
06-06-2023

Tender Details

Repair / Maintenance Of Air Conditioner, Deep Freezer, Voltage Stabilizer And Repair To Summer Appliances Water Cooler, Refrigerator And Its Connected Items At Af Stn Purnea Under Ge ( Af ) Purnea.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-May-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-06-2023
2 01-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 21000.0 /-
Tender Value
INR 10.49 Lakhs /-

BOQ Items

Name of Work:REPAIR / MAINTNANCE OF AIR CONDITIONER, DEEP FREEZER, VOLTAGE STABLIZER AND REPAIR TO SUMMER APPLIANCES WATER COOLER,REFRIGERATOR AND ITS CONNECTED ITEMS AT AF STN PURNEA UNDER GE (AF) PURNEA.
Sl. No. Item Description
1Taking down defective Refrigerator 155/165/170/175/210/315 litrs Capacity including Transportation from MES Store Yard/Site to Workshop and back including re-fixing/reinstalling, Testing, Connecting the same after replacement of Defective parts/Burnt Compressor Selected Unit with new Compressor obtained from authorised dealer including Flushing of Con-denser and Charging with required quantity of appropriate Refrigerant Gas, complete all as specified and as directed. Note:- Visit to be done by concerned OEM Rep only. Change of spare parts shall be measured separately under relevant item here-in-after as supply only rates fixing charges for spare parts shall deemed to be inclusive in the quoted rates. Old replacedmaterial has to be shown to Engr-in-Charge measured under sch of credit.
2Supply only Ice Cooling Chamber (as Approved) for Refrigerator 180/210/315 LITER Capacity for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.
3Supply only Starting Relay (OPEN TYPE/BOX TYPE) for Refrigerator of any Capacity for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.
4Supply only chiller tray for refrigerator for 300 ltrs Capacity for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.
5Supply only Chiller tray for refrigerator for 165 litrs Capacity for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.
6Supply only vegetable tray for refrigerator for 165 litrs Capacity for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.
7Supply only vegitable tray for refrigerators 286/300litre capacity for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.
8Supply only door hinges suitable for referigerator 300/ 165 litre Capacity for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.
9Supply only PVC refrigerator stand suitable for 286/310 litre refrigerator for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.
10Supply only PVC refrigerator stand suitable for 165 litre refrigerator for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.
11Supply only door rubber inner liner suitable for refrigerator capacity 165 ltrs for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.
12Supply only door rubber inner liner suitable for refrigerator Capacity 286/300 ltrs for fixing against defective parts of Refrigerator taking down under item No 1 here in before complete all as specified and as directed.
13S&Fin repairs fancy type push taps, chromium plated cast copper alloy 15 mm bore & screwed for iron pipe and fixed, complete all as specified and as directed.
14S&F in repair steel Connection with brass unions at both ends with brass nuts of length 600mm long etc, suitable for fixing to 15 mm dia GI Pipe, complete all as specified and as directed.
15S&F in repair PVC ball valve 15mm dia high pressure of PTMT with epoxy coated aluminium rod &high density plastic ball screwed for iron pipe and fixed suitable for water coolers, complete all as specified and as directed.
16S&F in repair PVC high density plastic ball screwed for iron pipe and fixed suiatble to fix to 15mm PVC float valve, complete all as specified and as directed.
17S&F in repair PVC drain out pipe 25 mm dia bore as per existing by providing necessary GI Clamps nuts bolts etc. complete all as specified and as directed.
18M&L for replacement of base plate of water cooler of any cacapcity, made out of 2mm thick MS sheet and painting with two coats of enamel paint over one coat of red oxide primer, complete all as specified and as directed.
19Taking down Defective Deep Freezer of 310 LITER Capacity, Transportation from MES Store Yard/Site to Workshop and Back including re-fixing /reinstallation after taking out defective parts/burnt Compressor Selected Unit & providing new Compressor of same Capacity from authorised dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas including Re-connection of All Electrical Connections, complete all as specified and directed. Note:- Visit to be done by concerned OEM Rep only.Change of spare parts shall be measured separately under relevant item here-in-after as supply only rates fixing charges for spare parts shall deemed to be inclusive in the quoted rates.Old replacedmaterial has to be shown to Engr-in-Charge measured under sch of credit.
20Taking down Defective Water Cooler 40/80/120/150 LITER Capacity, Transportation from MES Store Yard/Site to Workshop and back including re-fixing /reinstalling, Testing, connecting the same after replacement of defective parts/burnt out Compressor Selected Unit with new Compressor from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas, complete all as specified and as directed. Note:- Visit to be done by concerned OEM Rep only.Change of spare parts shall be measured separately under relevant item here-in-after as supply only rates fixing charges for spare parts shall deemed to be inclusive in the quoted rates. Old replacedmaterial has to be shown to Engr-in-Charge measured under sch of credit.
21M&L for rewinding fan fotor of existing water cooler 40/80 and 120/150 Liter capacity with suitable size copper wire including taking out unserviceable rewinding from fan motor, complete all as specified and as directed.
22Supply only Starting Relay for Water Cooler 40/80/120/150 LITRE Capacity for fixing against defective parts of Water cooler taking down under item No 20 here in before complete all as specified and as directed.
23Supply only door rubber inner liner (magnetic)suitable for water cooler capacity 40 ltrs for fixing against defective parts of Water cooler taking down under item No 20 here in before complete all as specified and as directed.
24Supply only door rubber inner ( Magnetic suitable for water cooler Capacity 80 ltrs for fixing against defective parts of Water cooler taking down under item No 20 here in after complete all as specified and as directed.
25Supply only door rubber inner liner ( magnetic) suitable for watercooler Capacity 150 ltrs for fixing against defective parts of Water cooler taking down under item No 20 here in after complete all as specified and as directed.
26M&L for repairs and overhauling of Voltage Stabilizer of 1.0 KVA, 2.0 KVA/3.0 KVA & 5 KVA Capacity of any MAKE including rewinding transformer, replacement of Relay, Capacitors, Switches, Voltmeters and Testing, etc., complete all as specified and as directed.
27Supply only Indicating lamp of any shape/size for VOLTAGE STABLIZER for fixing against defective parts of Geysercomplete all as specified and as directed.
28Supply and fix in repair stainless steelbraided pipe,EPDM Inner tube, copper inner joint built-in silica seal brass nutthread with washer and chrome finish 18 inchlong for Geyser of 25/35/50 Ltrs capacity for fixing.complete all as specified and as directed.
29All as per item no. 28 here in before but for 36 inch long complete all as specified and as directed.
30Supply and fix in replacement of non-return valve made out of brass vertical type 15 mm dia with new one ISI marked complete all as specified and directed
31Supply and fix PVC insulated3 core multistranded copper conductor cable of size 2.5 Sqmm a color code (Red for Phase, Black for Neutral and green for earth conductor) including taking down the old unserviceable cable complete all as specified and as directed.
32Supply and fixing in repairs of3 pin plug top AC-230 Volts 15 Amp, complete all as specified and as directed.
33M&L for Servicing of Aqua Guard, RO any type/make including replacement of micron cartridge,ultra filter, pre- filter,RO membrane with cleaning of inlet outlet pipe upto water cooler including repair of raw water feed pump and repair of internal wiring refixing in same location and re-writing of MES No. complete all as specified and as directed.
34M&L for Sub main wiringwith two single core PVC insulated unsheathed cable 1100 volts grade, 6.0 Sqmm size with multistranded copper conductor FRLS cable (with colour code), drawn through and including PVC casing capping of suitable size wirh ISI marked medium grade including all accessories ofcasing caping as approved by EIC, including PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly complete all as specified and as directed. Notes:- (i) Three run of single core 6.0 sqmm cable & one run of PVC casing capping shall be measured as one unit length.
35Taking down old unserviceable sub main wiring of any size and any description complete all as specified and as directed.
36S&F single pole and neutral enclosure with two pin and earth,plugand socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, including taking down old unserviceable ones, complete all as specified and as directed.
37Supply and fix modular plug and socket 25 Amp, 3 Pin 3 Pole having 6 modules having motor starter Modular Type 25 A, MCB mini SPN 25A 3 KA, Socket 25A, suitable for Air-condition supply,240 volts, AC, 50 Hz including taking down old plug enclosure and making good surfaces, complete all as specified and as directed ,
38S&F in repairs MCB SPN 240 volts 40 Amps, 10 KA breaking capacity,"C" Curve including connection with suitable size copper lugs complete all as specified and as directed.
39S&F in repairs MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity,"C" Curve including connection with suitable size copper lugs complete all as specified and as directed.
40Supply and filling Gas Charging with R-22 /R134a/R-32 Gas of AC (Window/Spilt Type) 1.5/2.0 TR Capacity with required quantity of Refrigerant in the Unit including Checking of Leakage in the System, Brazing the Leakage Parts of Oil Gas Tubing as required, complete all as specified and as directed.
41Taking down/up defective AC (Window/Split Type) 1.5/2.0 TR Capacity, Transportation to MES store yard/site to workshop and back including re-fixing /re-installing after servicing and repair including testing complete all as specified and as directed. Note:- charging of gas shall be measured separately under relevant item here-in-after.
42M&L for servicing of 1.5/2.0TR capacity window/split type AC disconnect from electric connection and open suction & dicharge pipe from outer unit , such as removing/ scrach dust with iron brush, cleaning condessor unit, compressor, cooling coil/cleaning of fan blade/cleaning of filter of inner unit etc,including (check thermostate, starting capacitior, running capacitor) with water & air blower, at the siteand reinstall at the same place and connect all electrical connection complete all as specified and directed by Engr-in-charge. Notes:- (i) Charging of gas shall be measured separately under relevant item here-in-after as required to fill as per requirement/manufacturer instruction.
43M&L for rotary type compressor sealed Unit 1.5 ton capacity from authorised dealer includingre-connection of electric connections, including removing old unserviceable compressor and functioning AC complete in all respect and testing, complete all as specified and as directed.
44All as per Item No. 43 here-in-before but for AC (Window/Split Type) 2.0 TR Capacity, complete all as specified and as directed.
45S&F Fan Motor of AC (Window/Split Type) 1.5 TR Capacity of approved Make and required Size to suit existing AC, including taking out the unserviceable fan motor from AC, complete all as specified and as directed.
46All as per Item No. 45 here-in-before but for AC (Window/Split Type) 2.0 TR Capacity, complete all as specified and as directed.
47S&FAir Circular Blower Fan Motor of AC (Split Type) 1.5 TR Capacity (as per Sample/Site Requirement) including taking out unserviceable Air Circular Blower Fan Motor from AC, complete all as specified and as directed.
48All as per item No. 47 here-in-before but for AC (split type) 2.0 ton capacity complete all as specified and as directed.
49S&Fprinted circuit board(PCB kit) for split type AC, 1.5 TR Capacity (as per Sample/ Site Requirement) including taking out unserviceable PCB includingfrom AC, complete all as specified and as directed.
50All as per item No. 49 here-in-befofre but for AC (split type) 2.0 ton capacity complete all as specified and as directed.
51S&F capacitor Running 36 mfd – 45 mfd of AC (Window/Split Type) 1.5/2.0 TR Capacity including taking out unserviceable Capacitor from AC, complete all as specified and as directed.
52S&F Capacitor Starting 80 mfd – 120 mfd of AC (Window/Split Type) 1.5/2.0 TR Capacity including taking out unserviceable Capacitor from AC, complete all as specified and as directed.
53S&F Fan Motor Capacitor 4 mfd of AC (Window/ Split Type) 1.5/2.0 TR Capacity including taking out unserviceable Fan Motor Capacitor from AC, complete all as specified and as directed.
54S&F Fan Motor Capacitor 6 mfd of AC (Window/ Split Type) 1.5/2.0 TR Capacity including taking out unserviceable Fan Motor Capacitor from AC, complete all as specified and as directed.
55S&F Starting Relay of AC (Window/Split Type) 1.5/2.0 TR Capacity including taking out unserviceable Starting Relay from AC, complete all as specified and as directed.
56S&F Thermostat Switch of AC (Window/Split Type) 1.5/2.0 TR Capacity including taking out unserviceable Thermostat Switch from AC, complete all as specified and as directed.
57M&L for Mild steel stand as per existing for AC Window type/Split type 1.5 to 2.0 TR capacity, grouting withBrick wall with Mild steel expandable bolts with steel rawl plug or floor mounted as per siteincluding making good walls in cement mortar (1:3) as required including dismantling old unserviceable mild steel stand for AC’scomplete all as specified and as directed.
58Supply and fixing in repair of copper capillary tube 5/8" as suitable size for repairing window/split type ACcomplete all as specified and as directed.
59Supply and fixing in repair of copper capillary tube 1/2" as suitable size for repairing window/split type ACcomplete all as specified and as directed.
60Supply and fixing in repair of copper capillary tube 1/4" as suitable size for repairing window/split type AC complete all as specified and as directed.
61Supply and fixing sensor for all type AC (split/window) 1.5/2.0 ton capacity complete including taking out unserviceable sensor from AC, complete all as specified and as directed.
62Supply and fixing transformer for split type AC 1.5/2.0 ton capacity complete including taking out unserviceable transformer from AC, complete all as specified and as directed.
63Supply and fixing air filter for split/window type AC 1.5/2.0 ton capacity complete including taking out unserviceable air filter from AC, complete all as specified and as directed.
64Supply and fixing swing blades for split/window type AC 1.5/2.0 ton capacity complete including taking out unserviceable swing blades from AC, complete all as specified and as directed.
65M&L for romoving of air conditioner of any type and capacity as per site reqirement and re-installing the same including necessary fixtures, complete all as directed by Eng-in-charge
66Supply and replace insulating material for Air Conditioner copper pipe of Suction,discharge,liquid line of various sizes. The insulating material shall have low conductivity, strength, Resistance to Fungi such as one that is based on ASTM G21 standard, excellent resistance to ozone and UV including removing the old insulation complete all as specified and as directed.
67Taking out existing burnt / unserviceable compressor unit from Refrigerator & replacing the same with factory builthermetically sealed compressor unit including necessary accessories and mounting material, welding, leak testing by charging dry Nitrogen gas, charging of refrigerantafter ensuring leak proof condition. Testingcomplete all as directed byEngineer-in-Charge. Note Refrigerant gas shall be measured and paid separately.
68Taking out existing burnt / unserviceable compressor unit fromwater cooler & replacing the same with suitable factory builthermetically sealed rotary compressorunit including necessary accessories and maintaining material, welding, leak testing by dry Nitrogen gas and chargingrefrigerant gas after ensuring leak proof condition and testingof water cooler 40 / 80 ltrs capacity complete all as directedby Engineer-in-Charge.
69Taking out damage indoor unit thermo plastic body from unit and supply and fixing of new indoor unit thermo plastic cover complete all as directedby Engineer-in-Charge.
70M&L for front grill suitable for window type AC 1.5 TR as per existing size.complete all as directedby Engineer-in-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail