Water Resources and Irrigation Local Bodies Closing in 0 days TDR #37531437

Tender For Jal Jeevan Mission (Jjm)-Jjm2021-2023-Cwss To Vellanad,Aruvikkara And Karakulam Panchayaths Supplying Conveying Testing And Commissioning 200Mm Di K9 Pumping Main,Construction Of 3Ll Capacity Sump And Pump Sets At Kummy Wtp In Karakulam Panchay

Issued by Local Bodies · karakulam, Kerala
Tender Value
1.74 Crore
Estimated cost
Bid Submission
09 May 2023
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
6508
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
karakulam → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Jal Jeevan Mission ( Jjm ) -Jjm2021-2023-Cwss To Vellanad, Aruvikkara And Karakulam Panchayaths Supplying Conveying Testing And Commissioning 200Mm Di K9 Pumping Main, Construction Of 3Ll Capacity Sump And Pump Sets At Kummy Wtp In Karakulam Panchayath-Jjm2021-2023-Cwss To Vellanad, Aruvikkara And Karakulam Panchayaths Supplying Conveying Testing And Commissioning 200Mm Di K9 Pumping Main, Construction Of 3Ll Capacity Sump And Pump Sets At Kummy Wtp In Karakulam Panchayath-Pipeline Work

BOQ

Work Name:Jal Jeevan Mission (JJM)-JJM2021-2023-CWSS to vellanad,aruvikkara and karakulam panchayaths supplying conveying testing and commissioning 200mm DI K9 pumping main,construction of 3LL capacity sump and pump sets at kummy WTP in karakulam panchayath-JJM2021-2023-CWSS to vellanad,aruvikkara and karakulam panchayaths supplying conveying testing and commissioning 200mm DI K9 pumping main,construction of 3LL capacity sump and pump sets at kummy WTP in karakulam panchayath-Pipeline Work
Sl. No. Item Description
11.Laying 200mm DI K9 pumping main from WTP at kummy to myladumpara
215.43.1:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Water bound macadam road
315.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
4100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.
5100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
6100.1.6:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 1.5m but not exceeding 3m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Ordinary Rock.
7100.1.9:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Hard Rock Requiring Blasting.
815.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
9100.8.2:Fencing 1.50m high with two rows of casuarina poles (girth 15cm to 24cm) tied with coir yarn on vertical casuarina pole (girth 15cm to 24cm) fixed at 1.5m intervals.
10100.14.3:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 200mm diameter Ductile Iron Class K-9 Pipes.
1118.83.5:Labour for cutting C.I. pipe with steel saw.200 mm diameter C.I. pipe
1218.17.3:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore
1318.25.1:Providing and laying S & S C.I standard specials such as tees, bends, collars, tapers, caps etc. (Heavy class):Upto 300 mm dia
1418.30.5:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:200 mm diameter pipe
1518.70.3:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:200 mm dia pipes
16100.35.3:Testing 200mm DI/CI pipeline with potable water to the required test pressure200 mm diaObserved Data derived from item no.1020 of PHED DATA
17100.31.1.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class I.
18100.31.1.5:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 200mm diameter, Class I.
19100.32.2:Conveying and fixing C. I. Single Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 40mm Single Acting Air Valve.
205.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
214.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
22100.98.117:Supply of DI K9 Pipe Conforming to IS 8329/2000, 200mm Dia.
23100.98.441:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 40mm.
24100.98.460:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 150mm.
25100.98.485:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 200mm.
262.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
274.1.2:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1/2:3 (cement : 11/2 coarse sand : 3 graded stone aggregate 20 mm nominal size)
284.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
294.3.2:Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
3013.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
31OD255552/2022-2023:Connecting the DI pipe/CI pipe to the tank using necessary duck foot bend and other specials for the smooth entry of water into the tank including all material, labour charges for cutting welding grinding etc including fixing the pipe at proper place by the direction of departmental officers
32OD255654/2022-2023:Supplying and fixing C.I with cover and frame for manholes:560 mm diameter (heavy duty) the weight to be not less than 208 kg.
332.appendix c-Construction of 3LL sump at WTP kummy
342.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
352.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock
364.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
375.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
385.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
3950.6.1.6:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete
405.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
415.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
425.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
435.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
445.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
455.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
4613.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
4713.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
4850.9.1.3:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). using good quality Vengai wood
4950.9.2.3:Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction of Engineer in -charge. using Vengai wood
5010.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
517.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
5213.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
53OD255667/2022-2023:Supplying 150mm wall casting pipe
5413.71:Lettering with black Japan pint of approved brand and manufacture
55100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.
563.Cost Materials
57100.98.118:Supply of DI K9 Pipe Conforming to IS 8329/2000, 250mm Dia.
58100.98.119:Supply of DI K9 Pipe Conforming to IS 8329/2000, 300mm Dia.
59100.98.120:Supply of DI K9 Pipe Conforming to IS 8329/2000, 350mm Dia.
60100.98.462:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 250mm.
61100.98.463:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 300mm.
62100.98.464:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 350mm.
634. Appendix G-Supply &amp:Errection of Pump sets
64100.37.7.1:In situ fabrication of M.S. pipes of size 200mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
65100.37.7.2:Fabricating M.S. flanges of diameter 200mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
66100.37.7.3:Cutting 200mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
67100.37.7.4:Welding 200mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
68100.37.7.5:Grinding cut and weld edges of 200mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
69Supplying, Installing and Commissioning of pump sets a
70100.31.1.5:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 200mm diameter, Class I.
71100.98.461:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 200mm.
72100.32.5:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 100mm Double Acting Air Valve.
73100.98.451:Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 100mm.
744.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
755.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
76OD256167/2022-2023:Supply and installation of flow meters and accessories of size 200 mm-Supplying an Electromagnetic Flow meter confirming to protection level of IP-65 for Flow sensor and IP 67 for transmitter and having an accuracy level of 0.5% with LED /LCD display unit. The flow meter should have the housing (Flow sensor) to be made of 155304/Carbon steel with anti corrosive protection and Inside liner to be made up to Hard Rubber/neoprene all confirming to drinking water standads. The flow meter should be coupled with HART for data acquisition and transfer with provision for wireless transfer through GSM. The manufacturer should have the calibration standards as per 180 17025 and the product shall have sufficient warranty provisions vide circular no. KWA /HO/SP-4014/2012/Flow meter and Soft starter dt 5/9/2012. The flowmeter has to be installed after cutting the existing 250 mm pumping main foxing the necessary flange pipes RCC Chamber with MH cover and all other required accessories as per the directions of department officers-Test certificate from FCRI Palakkad.
77OD256168/2022-2023:design ,testing,supply ,erectiontrial run and commissioning of centrifugal pump sets (2<br>nos <br >) 23.15 LPS against a totalhead of 120.78 m and having 960 to3880 rpm sync, speed ,bronze LTB2 impeller , SS <br>316<br> shaft ,cast iron casting , bronze LTB2 neck ring, SS410 sleeve, sqirrel case EF2 motor with a complete <br> integreted bypass<br> contractorin the panel and motor protection relay having parameters as per IE rules , with a <br> power control MCCB and <br> line power contractor .
78OD256169/2022-2023:Suppiying .convey and fixing 200 mm Zero Velocity valve, Conforming to IS 5312 Part I- 1984onsiruct valve chamber with RCC 1:115:3 (1 cement 1.5 coarse sand :3 graded sioneggregat0 20<bpmm nominal size and fixing heavy duty MH Cover with frame (208Kg (b00 X b00 mm o60 mm dia )<brelc as per the dlrection of department oflicerssbr
79100.31.1.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class I.
80100.98.458:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 100mm.
81Electrification works at pumphouse
8215.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
8315.9.2:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar
84OD256481/2022-2023:Supplying ang laying of 25*3 mm size copper earthing conductors along with cable
85OD256482/2022-2023:Supplying and wiring points acording to IS 732 is using rigigid pvc pipes using 1sqmm FR PVCinsulated stranded single core copper conductor etc. complele as per sepecification (SI no. 120) singlecontrol light point (rate as per Sl 120a1)
86OD256483/2022-2023:Supplying and wiring points according to IS 7/32 is using rigigid pvc pipes using9 1sqmm FR PVC|insulated stranded single core copper conductor etc. complete as per sepecification (Sl no. 120) singlecontrol celing lan with electronic regulator (rate as per Sl 120a7)
87OD256484/2022-2023:Supplyingand wiring points according to IS 732 is using rigigid pvc pipes using 1sqmm FR PVC insulatedStranded single core copper conductor etc. complete as per specification (SI no. 120) single control lightpoint with 6 A 5 pin plug (rate as per Si 12033)
88OD256485/2022-2023:Supply.conveyance.installation, lesting and commissioning of 1200 mm sweep-5 star rated ceiling fanUsing standard accessories excluding resistant type regular wiring the down rod with 16/0 .2mm PVCInsulated and PVC sheathed 650/1100 V grade 3 core round copper conductor flex wire or with extendedwith original wiring as requied
89OD256486/2022-2023:Supply and installation of sheet steel phosphatised and painted dust and vermin prof enclosure of MCBDB 8 way including copper /brass bus bar nuetral link earth bus and DlN rail suitable for fixing MCBisolator etc. fixed on wall using suitable anchor bolts or recess including cutting hole on the wall makinggood the damages colour washing elC. as required 8 way single phase double cover(IP 42/43)
90OD256487/2022-2023:supply and wiring light points with 6A plate ceiling of according to various 732- 1989 using rigid PVCconduit of minimum Ssize 20 mm with specials conforming to Is 3419 -1988 fixing the conduit using methylsaddles spacing nol exceeding 50cm concealed suitably and with 1 sq mm FR PVC insulated standednchayath-Susingle core copper conductor cable 650B grade lncluding providing switch board main and continuousCREATEearthing earth socket brass Bolt and nuts crimpling soldering etc compete with Sultable size modular typeof metal switch boxes modular type of front plates (white) etc up to and including 6A modular type SPSwitches and making good the surface of wall colour washing etc complete all the terminations in switichboards and the DB' shall be tinned and wires shall be drawn and fixied along the Periphery of the boxusing sutable 1ies tie mounts elc. as required
91OD256488/2022-2023:Providing and fixing water level indicator with aluminium channel so as to move the indicator pointerguage marked on aluminium sheet 0.5 mm thick,160 mm 4 Kg pvc pipefixed with SS clampsto move 140mm Dia pvc float tied with plastic stay wire,elc.as per direction of departmental officers.
92OD256489/2022-2023:Supplying and laying one number PVC insulated and PVC sheeted XLPE power cable of 1.1 KV gradefollowing size in masonry open duct as required (S&L of 3x/70sqmm copper armored cable) Owo run
93OD256490/2022-2023:Supplying and laying one number PVC insulated and PVC sheeted/ XLPE power cable of 1.1 KV gradeoWIg SIze in masonry open duct as required (S&L of 2x50sqmm cOpper armored cable) (wo run)
94OD256491/2022-2023:spplying and fixing yard lighting with GI pole and LED light
95OD256492/2022-2023:Supplying and laying of 8 SWG copperconducters along with cable/duct bellow ground including connecton /terminating with nut bolt spring wash etc are required
962.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
974.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
987.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
996.1.1:Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
10013.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
10113.62.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to givean even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture .
10213.63.1:Painting with aluminium paint of approved brand and manufacture to give an even shade.Two or more coats on new work
10316.68:Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
10416.69:Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

AI Tender Summary

OUR REF NO 37531437
AUTHORITY Local Bodies
TENDER VALUE 1.74 Crore
LAST DATE 09-05-2023
Authority
Authority Name Kerala Water Authority
Work Description Jal Jeevan Mission ( Jjm ) -Jjm2021-2023-Cwss To Vellanad, Aruvikkara And Karakulam Panchayaths Supplying Conveying Testing And Commissioning 200Mm Di K9 Pumping Main, Construction Of 3Ll Capacity Sump And Pump Sets At Kummy Wtp In Karakulam Panchayath-Jjm2021-2023-Cwss To Vellanad, Aruvikkara And Karakulam Panchayaths Supplying Conveying Testing And Commissioning 200Mm Di K9 Pumping Main, Construction Of 3Ll Capacity Sump And Pump Sets At Kummy Wtp In Karakulam Panchayath-Pipeline Work
Basic Detail
Tender No 14/2023-24/KWA/PHC/D3/TVM
Bidding Type Tender
Location
City karakulam
State Kerala
Key Dates
Publish Date 04 May 2023
Submission Date 09 May 2023
Open Date 10 May 2023
Finance
Tender Value 1.74 Crore
Tender Fee 6508
EMD 50000
Exemption Not Available
Document List
8f2891f2-d550-4f6f-a3cc-7f1b6ea74b3b.html
BOQ_848396.xls
KWAGeneralConditionsforeTenderingV5.pdf
nit14.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 04, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
May 09, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 10, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

8f2891f2-d550-4f6f-a3cc-7f1b6ea74b3b.html

xls

BOQ_848396.xls

pdf

KWAGeneralConditionsforeTenderingV5.pdf

pdf

nit14.pdf

pdf

Tendernotice_1.pdf

Disclaimer