| 1 | Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, leveling, ramming the foundationtrenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l.(BCD-5.1.1+5.1.2) |
| 2 | Filling in foundationtrenches and plinth in layers ---do---do-- as per directon of E/I.(BCD -5.1.8) |
| 3 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including\" cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement compacted volume).(BCD -5.1.10) |
| 4 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.(BCD -5.6.3) |
| 5 | Providing P.C.C.M - 150 with nominal mix of (1:2:4) in foundation with approved quality of stone metal grade III (50 mm to 25 mm size) clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/l.(BCD -5.3.1.2) |
| 6 | Providing R.C.C.M - 200 with nominal mix of (1:1.5:3) in foundation and plinth with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/l.(BCD -5.3.9.1) |
| 7 | Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. (BCD -5.2.6) |
| 8 | Providing R.C.C.M- 200 with nominal mix of (1:1.5:3) in columns with approved quality of stone chips 20 mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/l. (BCD -5.3.10) |
| 9 | Providing designation 75 B brick work in C.M (1:6) in superstructure with approved quality of clean coarse sand of F.M 2 to 2.5 including providing 10 mm thick mortar joints cost of screening materials , scaffolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l.(BCD -5.2.14) |
| 10 | Providing R.C.C.M - 200 with nominal mix of (1:1.5:3) in lintel with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, centering, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/l.(BCD -5.3.11) |
| 11 | Providing and laying damp- proof- course 50mm thick with cement concrete 1:2:4 ---do----do---- as per direction of E/I.(BCD -5.3.5) |
| 12 | Providing av. 63mm thick R.C.C.M-200 with nominal mix (1:1.5:3) in chajja with approved quality of stone chips 20 mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including making drip course in concrete, screening, centering, shuttering and mixing cement concrete in mixer and placing in position, vibrating, striking, 6mm cement plaster (1:4) in ceiling and sides of chajja with sand of F.M. 1.5 curing (but excluding the cost of reinforcement) taxes, and royalty all complete as per building specification and direction of E/l.(BCD -5.3.11) |
| 13 | Providing R.C.C.M - 200 with nominal mix of (1:1.5:3) in beam with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, centering, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/l..(BCD -5.3.11) |
| 14 | Providing R.C.C.M - 200 with nominal mix of (1:1.5:3) in roof slab with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, centering, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/l..(BCD -5.3.11) |
| 15 | Supplying, fitting and fixing 20 guage G.C.I, sheet gate fitted on M.S. Angle frame of size 60x60x6mm. including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l..(BCD -5.5.29) |
| 16 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.).(BCD -5.5.12) |
| 17 | Providing and laying Doublecharge vitrified floor tiles in different sizes(thickness to be specified by the manufacturer) with water absorptionless than 0.08% and conforming to IS: 15622 / ISO 13006 of approvedmake, in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm .(BCD -5.6.28) |
| 18 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I.With \"A\" grade white 15X15cm Tiles..(BCD -5.6.23.1) |
| 19 | Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5including screening, curingwithall leadsand liftsof water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.(BCD -5.7.6) |
| 20 | Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curingwithall leadsand liftsof water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.(BCD -5.7.2) |
| 21 | Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete.(DSR -13.26) |
| 22 | Providing two coats of dry distemper of approved shade and make over old surface including washing cleaning and preparing the walls, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/l.(BCD -5.8.14) |
| 23 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied@ 2.20 kg/10 sqm)(DSR -13.47.1) |
| 24 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing rust , dirt, , scales , smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/l. ( Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specification) .(BCD -5.8.41+45) |
| 25 | Providing Tor steel reinforcement of 10mm. ,12mm & 16mm dia. bars as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l.l.(BCD -5.5.5) |
| 26 | Centering and shuttering including strutting, proping etc and removal of formwork for foundation ,footing ,bases of column etc for mass concreteing.(BCD -5.3.17.1) |
| 27 | Centering and shuttering including strutting , proping etc and removal of formwork for Columns, piers, pillars, Abutments,posts and struts(BCD -5.3.17.6) |
| 28 | Centering and shuttering including strutting , proping etc and removal of formwork for lintels, beams, plinth beams,girder and cantilevers (5.3.17.5) |
| 29 | Centering and shuttering including strutting , proping etc and removal of formwork for chajja(5.3.17.19) |
| 30 | Centering and shuttering including strutting , proping etc and removal of formwork for suspended flors and roofs, balconies and access platform(BCD -5.3.17.3) |
| 31 | M.S. pipe 150 mm diapipe For goal post. DSR 7743 |
| 32 | Steel work in built up tubbular (round square or rectangular hollow tubes etc. ) trusses etc. , including cutting hoisting , fixing in position and applying a priming coat of approved steel primer m including welding and bolted with DSR 10.16.1 |
| 33 | Providing and fixing precoated galvanise iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge)0.63 mm+0.05%,total coated thickness with zinc coating 120 gsm as per IS:277in 240 mpa steel grade ,5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25mm microns minimum to -do-do of E/I. DSR 12.1.3 |
| 34 | Providing and fixing precoated galvanise iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge)0.63 mm+0.05%,total coated thickness with zinc coating 120 gsm as per IS:277in 240 mpa steel grade ,5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25mm microns minimum to -do-do of E/I. DSR 12.5.1 |
| 35 | Sanitary.Providing and fixing G.M non return valve Horizontal / vertical type of approved quality as per specification and direction of E/I.Horizontal - 25 mm dia |
| 36 | Cutting chhaja or cornice for laying G.I pipe and restoring the same with R.C.C(1:2:4) Brick work in cement mortar (1:4) as per specification and direction of E/I. |
| 37 | Making holes in walls for laying G.I pipe and restoring the same after pipe laying as per specification and direction of E/I.(a) 125mm thick wall |
| 38 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I.Mirror(450mm X 300mm) |
| 39 | C.P brass shoap dish container medium quality with screw and hinges etc |
| 40 | Supplying, fitting and fixing viterous earthen ware I.W.C. of parry hindustan or any other ---------do------do--------all complete as per specification and direction of E/I. 580 mm long - with 12.5 ltr. Low level P.V.C cistern |
| 41 | supplying fitting and fixing viterous white glazed earthen ware hand wash basin of parry hindustan or any other I.S.S approved ---------do------do------ all complete as per specification and direction of E/I. |
| 42 | Earth work in excavation for laying different types and sizes of R.C.C spun pipes with disposal of excavated earth within initial lead and lift as per specification and direction of E/I. 15 X 0.30 X 0.6= 2.7 m3 |
| 43 | Labour for laying, fitting and fixing NP2 R.C.C spu pipe with colors in lines, level and grade-------do-----do--------all complete as per specification and direction of E/I.150 mm dia RCC spun pipe - upto 3.0 m depth of invert below G.LSupplying and fixing NP2 Hume pipe etc.(150mm dia) |
| 44 | Supplying and fixing NP2 Hume pipe etc.(150mm dia) |
| 45 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.110 mm diameter |
| 46 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single pushfit Coupler. 110 mm |
| 47 | Single tee with door. 110x110x110 mm |
| 48 | Single tee without door.110x110x110 mm |
| 49 | Bend 87.5°.110 mm bend |
| 50 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 25 mm nominal outer dia Pipes |
| 51 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 15 mm nominal outer dia Pipes |
| 52 | 20 mm nominal outer dia Pipes |
| 53 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 54 | Providinfg and fixing male ended 15 mm dia brass bib cock of approved quality ( wt. not less than 350gms.)with extra socket all compare as per specification and direction of E/I. |
| 55 | Making holes in walls for laying G.I pipe and restoring the same after pipe laying as per specification and direction of E/I.(a) 250mm thick wall |
| 56 | Electrical.Point wiring in PVC conduit, with piano type swtich:-Wiring for point /fan point /exhaust fan point /call point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch ,phenolic modular plate, suitable size PVC/G.I. box etc.as Group A |
| 57 | Wiring for light/ power plug with 2x4 sq mm Power plug wiring in pvc conduit 2x4 sq mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit along with 1No.4sqmm FRPVC insulated copper conductor single core cable for loop earthing as required . |
| 58 | S/F PVC/G.Ibox of following size on surface or it recess with suitable size of phenolic laminated sheet cover infront including painting etc as required , 210mmx206mmx48 mm deep (10\"x12\") |
| 59 | Supplying and fixing following piano type switch/ socket on the existingmodular plate and switch box including connection but excluding modular plate . As required. 5/6 amps,one way switch |
| 60 | Supplying and fixing following piano type switch/ socket on the existingmodular plate and switch box including connection but excluding modular plate . As required. 5/6 amps,3 pin socket outlet |
| 61 | 15/16 watt led bulb |
| 62 | ceiling fan 48\" (1200mm) |
| 63 | suppling and fixing stepped tpye electronic fan regulator on the existing modular plate and switch box including connections but excluding modular plate as required. |
| 64 | Supplying and fixing 6 amps to 32 amps rating , 240 volts, \"B\" series , miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning , etc. as required. 6/32, single pole \"b\" series |
| 65 | S/F DP MCB Isolator :-Supplying and fixing following rating , double pole, 240V, isolator in the existing MCB DBcomplete with connections, testing and commissioning , etc. as required. 40 amp |
| 66 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 67 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 68 | Supplying all materials labour and tool & equipment for drilling 200mm x 165 mm dia X180 mtrs deep bore well in any kinds of soil and rocks in Rular or anyarea for installation of pump set withD.T.H super rig machine and ball hammer including all technology of mobilization of rigs air compressor all accessories of rigs tools and plant labour etc all complete job including transportation charge cost of flushing charge , geographical investigation etc all complete0.00 M to 50.00 M below G.L |
| 69 | 51.00 M to 180.00 M |
| 70 | Supplying all tools , tackles & lowering of 200 mm dia ,MSERW casing pipe of 6mm wall thickness including jointing charges , cost of pipe etc including all taxes , Vat , excise duty , freight charges with inspection charges etc as applicable , etc all complete job as per specification and direction of E /I |
| 71 | Supplying and fitting MS cap over 200 mm dia casing pipe for safety of dried bore including provision of guard for safety of the same till returned final all complete job as per specification and direction of E /I |
| 72 | Supplying all tools equipments and labour & doing washing , flushing and all complete job. |
| 73 | Supplying all tools, equipments and labours and lowering 32 mm dia medium qulity G.I pipe in drilled tube well in 3 mtrs length all complete as per directions of E/I |
| 74 | Supplying all tools, equipments and labours for fitting and fixing deep well cylinder with neccesary rod all complete as per directions of E/I |
| 75 | supplying all materials,labours and fixing india mark II hand pump with all complete job as per direction of E/I . Inciuding carriage cost, |
| 76 | Supplying all labours, tools & equipments for construction of 185 mm dia circular plateformas per UNICEF design etc. all complete job as per direction of E/I. |
| 77 | Supplying all labours, tools & equipments for construction of PCC(1:2:4)Drain as per UNICEF design etc. all complete. |
| 78 | Cost of one no. of standard I.S.I markeddeep well hand pump forindia Mark II I.S.I 15500 (PART 2)/2004 with latest revision 12 mm x 3m long 8 nos connecting rods made of bright bar electro -galvanized fitted with coupler & normal stand assembly suitable for bore well dia 100 to 125 mm casing pipe. |
| 79 | Cost of 32 mm dia G.I pipe 3 mtrs long (medium) with seamless socket as per relevent 8.1.5 specification. |
| 80 | Supplying material, labors and tools 125mm dia Blue UPVC Pipe with lowering charges etc. |
| 81 | Coat Of Cylinder mark II |
| 82 | Carriage of materials (A) Cement |
| 83 | (B) Sand |
| 84 | (C ) Chips |
| 85 | ( D)Brick |
| 86 | ( E ) Steel |
| 87 | G.S.T @ 18% |
| 88 | Labour Cess 1% |