Paschimanchal Vidyut Vitran Nigam Limited has published Works At Proposed Increasing Capacity Of 33/11Kv Substation Raghunath Pur, Ghaziabad From (2X5)Mva To (5+10)Mva. Submission Date for this Tender is 12-05-2023. Civil Work Tenders in ghaziabad Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

37521916
Works At Proposed Increasing Capacity Of 33/11Kv Substation Raghunath Pur, Ghaziabad From (2X5)Mva To (5+10)Mva
Open Tender
Indian
Uttar Pradesh
ghaziabad
12-05-2023

Tender Details

Works At Proposed Increasing Capacity Of 33 / 11Kv Substation Raghunath Pur, Ghaziabad From ( 2X5 ) Mva To ( 5+10 ) Mva- 1 1. Safe Loading, Carriage & Unloading Of Following Stock Materialfrom Any Stores Centres Under Pvvnl, Depending Upon The Availability Of Material At Stores Centres, With Loading & Unloading At Both Ends Respectively.A ) . 33Kv Vcb 1250A 2 B ) . 33Kv Ct 400 / 200 / 1-1-1A 3 C ) . 33Kv Control & Relay Panel With Differential Relay. 4 D ) . 33Kv Line Isolator 5 E ) . 11 Kv Xlpe Cable 3X300sq.Mm 6 F ) . 11Kv Cable J / Kit 3X185mm² 7 G ) . 33Kv Post Insulator 8 H ) . M.S.Channel / Angle 9 I ) .M.S.Round 32Mm Dia 10 2. Miscellaneous Works Of Increasing Capacity Of 33 / 11Kv S / S Raghunath Pur, Murad Nagar Ghaziabad ( 2X5 ) Mva To ( 5+10 ) Mva A ) . Hiring Of D / G Set Including Carriage, Loading, Unloading & Operating Charges ( With Fuel ) At 33 / 11Kv Substation Under Construction In Case L.T. Supply Is Not Available Near S / S Within Prescribed Accessible Limit.63Kva, Three Phase, D / G Set For Fabrication Of Different Structure At Substation. 11 3. Removal Of Existing 5Mva Transformer And Other Accessories Equipments.A ) . Disconnecting Ht Cable Connection From 33Kv Side &11Kv Side Of 5Mva Power Transformer For Removing Power Transformer From Plinth After Proper Shutdown. Dismantling Of 11Kv Cable Support Structure, Copper Bus Bar Structure, M.S.Frame Etc. 12 B ) . Disconnecting Copper Flexible / Earthing Strip From Power Transformer Neutral & Dismantling Neutral Earthing Systemto Facilitate Removal Of Power Transformer From Plinth. 13 C ) . Disconnecting Earthing Strip From Body Of 05Mva Power Transformer. 14 D ) . Draining Of Transformer Oil From Conservator, Radiators Of Existing 05 Mva T / F, At 33 / 11 Kv S / S Raghunath Pur Into The Dry & Clean Drums And Stacking At The Safe Place In Substation Outside Of Switchyard. Empty Drums Shall Be Provided Bycontractor 15 E ) . Removal Of Conservator, Radiators And Other Accessories From Existing 5 Mva Power Transformer. 16 F ) . Safe Shifting Of 5 Mva Power Transformer Main Body And Other Accessories From The Substation Switchyard To Outside The Switchyard At Suitable Place Assigned By Concern J.E / S.D.O ( Distribution ) . 17 G ) . Re-Assembling Of Conservator, Radiators And Other Accessories To Existing 5 Mva Power Transformer. 18 H ) . Re-Filling The Transformer Oil ( Old & Used In Existing 5Mva T / F ) 19 4. Installation For 33 / 11Kv 10Mva T / F A ) . Safe Shifting Of 10Mva, 33 / 11 Kv, Power Transformer From Out Side Of Switchyard To Near Power Transformer Plinth In Switchyard. 20 B ) . Erection & Installation Of 10Mva Power Transformer On Power Transformer Plinth By Fixing All Accessories Like Radiators, Conservator Tank, Filling The Transformer Oil To Desired Level And Ensuring That There Is No Leakage, Complete Job In All Respect. Reconnecting 2 Nos. Earthing Strip To Transformer Body. 21 5. Water Level Earthing By Boring And Lowering Of G.I. Pipe Of Size 40 Mm Dia & Thickness 2Mm ( Id-36Mm, Od-40Mm ) Into The Ground At 50 Mtr ( 160Feet ) Depthupto The Water Level. The Lower End Of Pipe Shall Be Provided With Solid Copper Cone Approx 225 Mm Long And 750 Gm In Weightand Screwed In Pipe And Bringing Out A Continuous Copper Wire Of 6 Swg From The Cone Up To The Power Transformer Neutral / L.A Where It Will Be Bolted To Them.S. Earth Strip For Transformer Neutral Connection. Welded To The G.I. Pipe And Neutral Earthing Support. No Joint In Copper Wire Is Allowed, 22 6. Fabrication And Erection Of Neutral Earthing L Type Support Made Of M.S. Channel Size 100X50mm. Structure Shall Be 4 Mtr. Long With 1 Mtr. Arms And 0.75Mtr Bracing. Structure Shall Be Grouted In Ratio 1:3:6 In Block Size 300X300x1000mm Including Plinth And Painted With One Coat Of Ready Mixed Primer And Two Coat Of Enamel Aluminium Paint Work Includes Connecting Neutral Bushing Rod Of Power Transformer And M.S. Earthing Strip With The Help Of Flexible Copper Bond, M.S. Bolt And Washer With Stone Pad Of Size ( 300X300x75mm ) . 23 7. A ) . Fabrication And Erection Of Cable Support Made Of Two Pieces Of M.S. Channel ( 100X50x6 ) Mm, 2.75 Meter Long, Joined To Each Other By Means Of 5 Nos. M.S. Angle ( 50X50x6 ) Mm Pieces Of Size 0.75Mtr Long Each By Welding At Equal Intervals And Grouting In A Block Of Size ( 300X1000x1000 ) Mm In C.C. 1:3:6 Complete With One Coat Of Ready Mixed Primer And Two Coats Of Al. Paint. Work Includes Providing Of Three Nos. M.S. Clamps Made Of ( 50X6 ) Mm M.S. Flat For Holding The Cable Including Nuts And Bolts With Stone Pad Of Size ( 300X300x75mm ) . 24 B ) . Fabrication And Grouting Of M.S. Frames 3.60 Mt. Long For Support Of Copper Bus Bar. Bus Bar Will Be Provided In L.V. Side Of Power Transformer. The M.S. Frame Shall Be Made Of M.S. Channel ( 100X50 ) Mm In T Shape. Providing 2 Nos. Support Of M.S. Angle Iron ( 50X50x6 ) Mm, 0.60Mt. Long Below The Top Channel, Drilling Of 3 Nos. Hole On The Top Channel For Fixing Of 11 Kv Pin Insulator. The M.S. Frame Shall Be Painted With One Coat Of Primer & Two Coat Of Aluminium Paint And Grouting The Frame In C.C. Ratio 1:3:6 In A Block Of Size ( 300X300x700 ) Mm With Stone Pad Of Size ( 300X300x75mm ) . The Work Also Includes The Fixing Of 3 Nos. 11 Kv Pin Insulator With Pin And Binding The Copper Bus Bar With The Pin Insulator By Aluminium Binding Wire In Complete. 25 8. Supply & Fabrication Of Copper Bus Bar Of Size ( 2500X50x6 ) Mm In L.V. Side Of 10 Mva 33 / 11 Kv, Power Transformer, Work Includes Connection Of Outside Bus Bar In L.V. Side Busing Rod Of Power Transformer And Other Side With Outdoor 11 Kv Cable Box As Well As Providing Empire Tape And H.T. Tape Etc. For Proper Insulation Work. 26 9. H.T. Power Cable Laying: A ) . Laying 11 Kv, ( 3X300 ) Mm2 / ( 3X400 ) Mm2 Xlpe, Cable From Power Transformer To 11 Kv Incoming Switch Gear In The Cable Trench 0.45 M Wide, 0.90M Depth. Providing 150 Mm Local Sand For Cushion Beneath And 150 Mm Above The Cable ( Quality Of Local Sand Required 0.375 Cum / M In Length ) . The Cable Shall Be Dully Protected By Brick. On Both Side Of Cable By Laying Brick Vertically And Bricks Would Also Be Laid Bricks Along The Cable ( Minimum 18 Nos. Of Bricks Are To Be Laid Top And Outer Side Along The Cable. The Work Includes Digging Of Trenches, Laying Of Cable In Under Ground Trenches, Joining Of TerminalS, Back Filling Of Earth And Testing And Commissioning Of Power Cable Etc. Spare Cable Shall Be Left Over And Laid In The Trenches In Shape Of 6 M Ring At Both Ends. 27 B ) . Laying And Dressing Of 11 Kv 3X300 Mm2 / 3X400 Mm2 Power Cable In Air / Trench. 28 10. Erection Of 33Kv Line Isolator On Isolator Structure With Proper Alignment & Fitting. 29 11. Plinth For 33 Kv V.C.B.Construction Of Plinth For The Structure Of 33 Kv Vcb & C.T.S As Per Details For 01 No.:-A ) . Excavation Of Earth Of Size ( 2.4X1.5X1.0 ) M Pits For Construction Of Plinth. 30 B ) . Brick Ballast Ratio ( 1:3:6 ) ( Cement, Sand & Stone Grift For Foundation Work ( 2.4X1.5X0.15 ) M Plinth. 31 C ) . R.C.C. Work In Ratio 1:2:4 ( Cement, Coarse Sand & Stone Grit Of 20Mm Size ) For Making Plinth Of Size ( 2.4X1.5X1.0 ) M And Grouting Of Foundation Bolts 04 Nos. For 33 Kv Vcb. 32 D ) . 12Mm Thick Plaster With Cement Mortar In Ratio 1:4 ( Cement & Fine Sand ) Of Plinth Of Side Size ( 2.4X1.5X0.4 ) M. 33 E ) .Laying Of G.I.Earth Strip Of Size 50X6mm For Connecting The Earth Mat With Steel Structure. The Work Also Includes Cutting, Bending, Straigthning, Over-Lapping And Welding The Earth Strip With Earth Mat And Various Steel Structures By Using High Quality Arc Welding In Already Digged Trenches. 34 F ) . Painting Of Earth Strip Of Size ( 50X6 ) Mm With One Coat Of Ready Mixed Primer With Two Coats Of Isi Mark Synthetic Oil Enamal Green Paint. 35 12. Preparation Of 11 Kv Power Cable Ends:A ) . Making Ofcable End Termination By Heat Shrinkable Out Door Jointing Kits Suitable For 11Kv, 3X300sq.Mm Xlpe Cable. Suitable Size Cable Jointing Kit Will Be Provided By Department Free Of Cost Execution Of Work. Providing, Fixing And Crimping Of Proper Size Good Quality Lugs Complete In All Respect. 36 B ) .Making Ofcable End Termination By Heat Shrinkable Indoor Jointing Kits Suitable For 11Kv, 3X300sq.Mm Xlpe Cable. Suitable Size Cable Jointing Kit Will Be Provided By Department Free Of Cost Execution Of Work. Providing, Fixing And Crimping Of Proper Size Good Quality Lugs Complete In All Respect. 37 13. Providing & Erection Of G.I. Strip Size 50X6mm For Earthing Of Outdoor & Indoorequipment 38 14. Installation Of 33 Kv Post Insulators:A ) . Installation Of 3 Nos. Pi On Structure. The Work Includes Fabrication For Proper Fixing, If Required. 39 B ) . Installation Of 33 Kv Vcbi ) . Assembling And Installation Of 33 Kv Vcb On The Vcb Out Door Structure On The Plinth. Adjustment Of Operating Mechanism In Proper Alignment For Smooth Operation Of The Same. The Work Also Includes Fabrication Of Addition Arrangement For Proper Fixing, If Required. 40 Ii ) . Installation Of 33 Kv C.T.S:Installation Of 3 Nos. C.T.S On The C.TS Structure. The Work Includes Fabrication For Proper Fixing, If Required To Complete The Work. 41 Iii ) . 33 Kv CtS Junction Box:Providing & Fixing Of Junction Box Of Size ( 400X400x150 ) Mm Made Of M.S. Sheet Of 16 Swg In Between 33 Kv CtS & Control Panel. The Work Also Include Making Proper Connection On The Junction Box And Making All Connection In Between CtS And Control Panel Complete As Per ManufactureS Panel Drawing Including Testing And Commissioning Of Work Etc. Complete The Work. 42 Iv ) . Installation Of 33 Kv Vcb Control Panelcarefully And Safely Shifting Of 33 Kv Vcb Control Panel From Outside Of The Switch Gear Room To Inside Of The Switch Gear Room, Grouting With Anchor Bolts In The Floor, Work Also Includes Cutting & Proper Finishing Of Floor If Necessary For Completion Of Work. Placing And Fixing Of Panel On Foundation, Bolts Of Proper Size In Proper Position And Alignment. 43 15 A ) .Providing & Laying Of 2X2.5Mm2control Cables I.S Marki.E. From Buchholz Realy To Marshalling Box Marshalling Box To Indication Protection Board In Switch Gear Room, 33 Kv CtS To CtS Junction Box, Ct 33 Kv, V.C.B. Control Panel Junction Box To 33 Kv Vcb Control Panel And Control Panel To 33 Kv Vcb Outdoor Operating Mechanism Panel From T / F Etc. In The Cable Trench Including Making Proper Connection At Buchholz Relay, Marshalling Box And Indication Board As Per Required For Installed Equipment. 44 B ) . Providing & Laying Of 4X2.5Mm2control Cables I.S Marki.E. From Buchholz Realy To Marshalling Box Marshalling Box To Indication Protection Board In Switch Gear Room, 33 Kv CtS To CtS Junction Box, Ct 33 Kv, V.C.B. Control Panel Junction Box To 33 Kv Vcb Control Panel And Control Panel To 33 Kv Vcb Outdoor Operating Mechanism Panel From T / F Etc. In The Cable Trench Including Making Proper Connection At Buchholz Relay, Marshalling Box And Indication Board As Per Required For Installed Equipment. 45 16. Earthing Of Outdoor Equipment, Details As Given Below:-A ) . Cutting Of 32Mm.Dia M.S. Bar-3Mtr.Long And Making One End In Conical Shape By Forging Process And Driving It Into The Earth At Each Corner Of Bridge And Proper Welding With M.S.Bars. 46 B ) . Digging Of Pits & Making Ofbridge On L.A. & T / F Neutral Earthingby Laying 32Mm. Dia M.S.Round In Rectangular Shape. Electric Welding On Cross Joints By Providing “U” Clamp In Size 25X6mm. Of M.S.Flat And Inter Connecting Both By M.S.Round 32Mm.Diawith Over Lap Joint By Providing M.S.Round-12Mm Dia, On Both Sides Of Over Lap Joints Of M.S.Round, By Electric Welding. All Joints Shall Be Painted With Black Bituminious Paint. 47 17. Testing & Commissioning Of Power T / F And All 33Kv & 11Kv Switchgears / Panels.Providing Required No. Of Technicians With Proper Testing Equipments During Commissioning & Energisation. 48 18. Painting Of Structurespainting Of The Following Structure With One Coat Of Ready Mixed Primer And Two Coats Of Isi Mark Aluminium Paint After Rubbing With Sand Paper To The Surface Of The Structure Including Labour And T&P Complete In All Respect.A ) . Post Insulator, Cable Support Structure And Neutral Support Structure, G.I.Strip, M.S.Frames.

Key Value

Document Fees
INR 1180 /-
EMD
INR 7500.0 /-
Tender Value
INR 7.42 Lakhs /-

BOQ Items

Name of Work:-Works at proposed increasing capacity of 33/11KV Substation Raghunath Pur, Ghaziabad from (2x5)MVA to (5+10)MVA
Sl. No. Item Description
11. Safe Loading, carriage & unloading of following stock materialfrom any stores centres under PVVNL, depending upon the availability of material at Stores Centres, with loading & unloading at both ends respectively. a). 33KV VCB 1250A
2b). 33KV CT 400/200/1-1-1A
3c). 33KV control & relay Panel with differential relay.
4d). 33KV line isolator
5e). 11 KV XLPE Cable 3x300Sq.mm
6f). 11KV cable J/kit 3x185mm²
7g). 33KV Post insulator
8h). M.S.Channel/Angle
9i).M.S.Round 32mm Dia
102. Miscellaneous works of Increasing capacity of 33/11KV S/S Raghunath Pur, Murad nagar Ghaziabad (2x5)MVA to (5+10)MVA a). Hiring of D/G Set including carriage, loading, unloading & operating charges (With fuel) at 33/11KV Substation under construction in case L.T. Supply is not available near S/s within prescribed accessible limit. 63KVA, Three phase, D/G Set for fabrication of different structure at Substation.
113. Removal of existing 5MVA Transformer and other accessories equipments. a). Disconnecting HT cable connection from 33KV side &11KV side of 5MVA Power transformer for removing power transformer from plinth after proper shutdown. Dismantling of 11KV cable support structure, copper bus bar structure, M.S.Frame etc.
12b). Disconnecting copper flexible/Earthing strip from Power transformer neutral & Dismantling neutral earthing systemto facilitate removal of Power transformer from plinth.
13c). Disconnecting Earthing strip from body of 05MVA Power transformer.
14d). Draining of transformer oil from conservator, radiators of existing 05 MVA T/F, at 33/11 KV S/S Raghunath Pur into the dry & clean drums and stacking at the safe place in Substation outside of switchyard. Empty drums shall be provided bycontractor
15e). Removal of conservator, radiators and other accessories from existing 5 MVA Power transformer.
16f). Safe Shifting of 5 MVA Power transformer main body and other accessories from the substation switchyard to outside the switchyard at suitable place assigned by concern J.E/S.D.O (Distribution).
17g). Re-assembling of conservator, radiators and other accessories to existing 5 MVA Power transformer.
18h). Re-filling the transformer oil (old & used in existing 5MVA T/F)
194. Installation for 33/11KV 10MVA T/F a). Safe Shifting of 10MVA, 33/11 KV, Power transformer from out side of switchyard to near Power transformer plinth in Switchyard.
20b). Erection & Installation of 10MVA Power transformer on Power Transformer plinth by fixing all accessories like radiators, conservator tank, filling the transformer oil to desired level and ensuring that there is no leakage, complete job in all respect. Reconnecting 2 Nos. earthing strip to transformer body.
215. Water level earthing by Boring and lowering of G.I. pipe of size 40 mm dia & thickness 2mm (ID-36mm, OD-40mm) into the ground at 50 Mtr (160feet) depthupto the water level. The lower end of pipe shall be provided with solid copper cone approx 225 mm long and 750 gm in weightand screwed in pipe and bringing out a continuous copper wire of 6 SWG from the cone up to the Power transformer neutral/ L.A where it will be bolted to theM.S. earth Strip for Transformer neutral connection. Welded to the G.I. pipe and neutral earthing support. No joint in copper wire is allowed,
226. Fabrication and erection of neutral earthing L Type support made of M.S. Channel size 100x50mm. Structure shall be 4 Mtr. long with 1 Mtr. Arms and 0.75Mtr bracing. Structure shall be grouted in ratio 1:3:6 in block size 300x300x1000mm including plinth and painted with one coat of Ready Mixed primer and Two coat of enamel Aluminium paint work includes connecting neutral bushing rod of power Transformer and M.S. Earthing strip with the help of flexible copper bond, M.S. Bolt and washer with stone Pad of size (300x300x75mm).
237. a). Fabrication and erection of cable support made of two pieces of M.S. Channel (100x50x6)mm, 2.75 meter long, joined to each other by means of 5 Nos. M.S. Angle (50x50x6) mm pieces of size 0.75Mtr long each by welding at equal intervals and grouting in a block of size (300x1000x1000)mm in C.C. 1:3:6 complete with one coat of ready mixed primer and two coats of Al. paint. Work includes providing of three Nos. M.S. clamps made of (50x6)mm M.S. Flat for holding the cable including nuts and bolts with stone Pad of size (300x300x75mm).
24b). Fabrication and grouting of M.S. frames 3.60 mt. long for support of copper Bus Bar. Bus Bar will be provided in L.V. side of Power transformer. The M.S. frame shall be made of M.S. channel (100x50)mm in "T" shape. Providing 2 Nos. support of M.S. Angle iron (50x50x6)mm, 0.60mt. long below the top channel, drilling of 3 Nos. hole on the top channel for fixing of 11 KV pin insulator. The M.S. frame shall be painted with one coat of primer & two coat of aluminium paint and grouting the frame in C.C. ratio 1:3:6 in a block of size (300x300x700) mm with stone Pad of size (300x300x75mm). The work also includes the fixing of 3 Nos. 11 KV pin insulator with pin and binding the copper Bus Bar with the pin insulator by Aluminium binding wire in complete.
258. Supply & Fabrication of copper bus bar of size (2500x50x6)mm in L.V. side of 10 MVA 33/11 KV, power transformer, Work includes connection of outside bus bar in L.V. side busing rod of Power Transformer and other side with outdoor 11 KV cable box as well as providing empire tape and H.T. tape etc. for proper insulation work.
269. H.T. Power Cable Laying: a). Laying 11 KV, (3x300) mm2/(3x400) mm2 XLPE, Cable from power transformer to 11 KV incoming switch gear in the cable trench 0.45 m wide, 0.90m depth. Providing 150 mm local sand for cushion beneath and 150 mm above the cable (quality of local sand required 0.375 cum/m in length). The cable shall be dully protected by brick. On both side of cable by laying brick vertically and bricks would also be laid bricks along the cable (minimum 18 Nos. of bricks are to be laid top and outer side along the cable. The work includes digging of trenches, laying of cable in under ground trenches, joining of terminal"s, back filling of earth and testing and commissioning of power cable etc. Spare cable shall be left over and laid in the trenches in shape of 6 m ring at both ends.
27b). Laying and dressing of 11 KV 3x300 mm2/3x400 mm2 power cable in air/Trench.
2810. Erection of 33KV line isolator on isolator structure with proper alignment & fitting.
2911. Plinth for 33 KV V.C.B. Construction of plinth for the structure of 33 KV VCB & C.T."s as per details for 01 No.:- a). Excavation of earth of size (2.4x1.5x1.0)m pits for construction of plinth.
30b). Brick Ballast ratio (1:3:6) (cement, sand & stone grift for foundation work (2.4x1.5x0.15)m plinth.
31c). R.C.C. work in ratio 1:2:4 (cement, coarse sand & stone grit of 20mm size) for making plinth of size (2.4x1.5x1.0)m and grouting of foundation bolts 04 Nos. for 33 KV VCB.
32d). 12mm thick plaster with cement mortar in ratio 1:4 (cement & fine sand) of plinth of side size (2.4x1.5x0.4)m.
33e).Laying of G.I.Earth strip of size 50x6mm for connecting the Earth Mat with steel structure. The work also includes cutting, bending, straigthning, over-lapping and welding the earth strip with Earth Mat and various steel structures by using high quality Arc welding in already digged trenches.
34f). Painting of Earth Strip of size (50x6)mm with one coat of ready mixed primer with two coats of ISI mark synthetic oil enamal green paint.
3512. Preparation of 11 KV Power Cable ends: a). Making ofcable end termination by Heat shrinkable Out door jointing kits suitable for 11KV, 3x300Sq.mm XLPE cable. Suitable size cable Jointing Kit will be provided by department free of cost execution of work. Providing, fixing and crimping of proper size good quality lugs complete in all respect.
36b).Making ofcable end termination by Heat shrinkable indoor jointing kits suitable for 11KV, 3x300Sq.mm XLPE cable. Suitable size cable Jointing Kit will be provided by department free of cost execution of work. Providing, fixing and crimping of proper size good quality lugs complete in all respect.
3713. Providing & Erection of G.I. Strip size 50x6mm for earthing of outdoor & indoorequipment
3814. Installation of 33 KV Post Insulators: a). Installation of 3 Nos. PI on structure. The work includes fabrication for proper fixing, if required.
39b). Installation of 33 KV VCB i). Assembling and installation of 33 KV VCB on the VCB out door structure on the plinth. Adjustment of operating mechanism in proper alignment for smooth operation of the same. The work also includes fabrication of addition arrangement for proper fixing, if required.
40ii). Installation of 33 KV C.T."s: Installation of 3 Nos. C.T."s on the C.T"s structure. The work includes fabrication for proper fixing, if required to complete the work.
41iii). 33 KV CT"s Junction Box: Providing & fixing of junction box of size (400x400x150) mm made of M.S. sheet of 16 SWG in between 33 KV CT"s & control panel. The work also include making proper connection on the junction box and making all connection in between CT"s and control panel complete as per manufacture"s panel drawing including testing and commissioning of work etc. complete the work.
42iv). Installation of 33 KV VCB Control Panel Carefully and safely shifting of 33 KV VCB control panel from outside of the switch gear room to inside of the switch gear room, grouting with anchor bolts in the floor, work also includes cutting & proper finishing of floor if necessary for completion of work. Placing and fixing of panel on foundation, bolts of proper size in proper position and alignment.
4315 a).Providing & Laying of 2x2.5mm2control cables I.S marki.e. from Buchholz realy to Marshalling box Marshalling box to indication protection board in switch gear room, 33 KV CT"s to CT"s Junction Box, CT 33 KV, V.C.B. Control Panel Junction Box to 33 KV VCB control panel and control panel to 33 KV VCB outdoor operating mechanism panel from T/F etc. in the cable trench including making proper connection at Buchholz Relay, Marshalling box and indication board as per required for installed equipment.
44b). Providing & Laying of 4x2.5mm2control cables I.S marki.e. from Buchholz realy to Marshalling box Marshalling box to indication protection board in switch gear room, 33 KV CT"s to CT"s Junction Box, CT 33 KV, V.C.B. Control Panel Junction Box to 33 KV VCB control panel and control panel to 33 KV VCB outdoor operating mechanism panel from T/F etc. in the cable trench including making proper connection at Buchholz Relay, Marshalling box and indication board as per required for installed equipment.
4516. Earthing of outdoor equipment, details as given below:- a). Cutting of 32mm.dia M.S. Bar-3Mtr.long and making one end in conical shape by forging process and driving it into the earth at each corner of bridge and proper welding with M.S.Bars.
46b). Digging of Pits & making ofBridge on L.A. & T/F neutral earthingby laying 32mm. dia M.S.Round in rectangular shape. Electric welding on cross joints by providing “U” Clamp in size 25x6mm. of M.S.Flat and inter connecting both by M.S.Round 32mm.diawith over lap joint by providing M.S.Round-12mm dia, on both sides of over lap joints of M.S.Round, by electric welding. All joints shall be painted with black bituminious paint.
4717. Testing & commissioning of Power T/F and all 33KV & 11KV switchgears / Panels.providing required No. of technicians with proper testing equipments during commissioning & energisation.
4818. Painting of Structures Painting of the following structure with one coat of ready mixed primer and two coats of ISI Mark Aluminium paint after rubbing with sand paper to the surface of the structure including labour and T&P complete in all respect. a). Post Insulator, Cable support structure and Neutral support structure, G.I.Strip, M.S.Frames.