Tender For Supply Of Ups System, panipat-Haryana

Indian Oil Corporation Limited-IOCL has published Tender For Supply Of Ups System. Submission Date for this Tender is 19-07-2023. MCCB Tenders in panipat Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

37509899
Corrigendum : Tender For Supply Of Ups System
Limitted
Indian
Haryana
panipat
19-07-2023

Tender Details

Supply Of Ups System Supply Of Ups System For P-25 Project (Epcm-2) At Iocl Panipat Refinery , Supply Of Uninterruptible Power Supply System Design, Construction, Assembly, Manufacturing, Testing Of Ups System At Vendor’S Works.Packing, Supply And Delivery To Site Complete With Accessories And Associated Equipment Which Are Required For Efficient And Trouble Free Operation.Supervision Of Installation, Testing And Commissioning Along With Accessories, Commissioning Spares, Special Tools & Tackles And Third Party Inspection For Epcm-2, P25 Project At Iocl Panipat Refinery As Specified In Material Requisition. , Following Ups Systems Complete With All Associated Equipments Such As Battery Bank, Non Integral Type Acdb & Accessories Such As Online Battery Monitoring System, Battery Mccb Box, All Interconnecting Cables Between Ac Ups, Acdbs, Battery And Battery Isolators, Battery Stand Assembly Etc. Along With Ups Pdb & Non-Ups Pdb (Including Commissioning Spares As Required) In Accordance With This Specification: A) Ups-11801 1 Ph, 2 Wire, 200 Kva, 110 V, 50 Hz, Dual Redundant Ups System With Acdb, 2 X 100 % Batterybank Along With Cell Booster Suitable For Supplied Battery Rating B) Ups-11901 1 Ph, 2 Wire, 130 Kva, 110 V, 50 Hz, Dual Redundant Ups System With Acdb, 2 X 100 % Batterybank Along With Cell Booster Suitable For Supplied Battery Rating C) Ups Pdb & Non-Ups Pdb Note: Technical Requirements And Quantity Of Ups Pdb & Non-Ups Pdb Shall Be As Specified In Technical Specification For Instrument Pdb (Doc.Id: 6745-Ins-000-Ec-0012) , Following Ups Systems Complete With All Associated Equipments Such As Battery Bank, Non Integral Type Acdb & Accessories Such As Online Battery Monitoring System, Battery Mccb Box, All Interconnecting Cables Between Ac Ups, Acdbs, Battery And Battery Isolators, Battery Stand Assembly Etc. A) Ups-11802 1 Ph, 2 Wire, 60 Kva, 230 V, 50 Hz, Dual Redundant Ups System With Acdb, 2 X 100 % Batterybank Along With Cell Booster Suitable For Supplied Battery Rating B) Ups-11902 1 Ph, 2 Wire, 40 Kva, 230 V, 50 Hz, Dual Redundant Ups System With Acdb, 2 X 100 % Batterybank Along With Cell Booster Suitable For Supplied Battery Rating => Limited

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-May-2023 Addendum_1_EL08_Comm_Clar1 Financial Bid 31-05-2023
2 31-May-2023 Addendum_2_EL08_Extn1 Date 21-06-2023
3 12-Jun-2023 Addendum_3_EL08_Tech Clar1 Technical Bid 21-06-2023
4 22-Jun-2023 Addendum_4_EL08_Extn2 Date 05-07-2023
5 06-Jul-2023 Addendum_5_EL08_Extn3 Date 19-07-2023

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: SUPPLY OF UNINTERRUPTIBLE POWER SUPPLY SYSTEM FOR P25 PROJECT AT IOCL PANIPAT REFINERY
Sl. No. Item Description
1SUPPLY OF UNINTERRUPTIBLE POWER SUPPLY SYSTEM Design, construction, assembly, manufacturing, testing of UPS system at vendor’s works.Packing, supply and delivery to site complete with accessories and associated equipment which are required for efficient and trouble free operation.Supervision of Installation, Testing and Commissioning along with Accessories, Commissioning spares, Special tools & Tackles and Third party Inspection for EPCM-2, P25 PROJECT at IOCL PANIPAT REFINERY as specified in Material Requisition.
2Following UPS systems complete with all associated equipments such as Battery bank, non integral type ACDB & accessories such as online battery monitoring system, Battery MCCB box, all interconnecting cables between AC UPS, ACDBs, Battery and Battery isolators, battery stand assembly etc. along with UPS PDB & Non-UPS PDB (including commissioning spares as required) in accordance with this specification: a) UPS-11801 1 ph, 2 wire, 200 kVA, 110 V, 50 Hz, Dual redundant UPS system with ACDB, 2 X 100 % BatteryBank along with cell booster suitable for supplied battery rating b) UPS-11901 1 ph, 2 wire, 130 kVA, 110 V, 50 Hz, Dual redundant UPS system with ACDB, 2 X 100 % BatteryBank along with cell booster suitable for supplied battery rating c) UPS PDB & NON-UPS PDB Note: Technical requirements and quantity of UPS PDB & NON-UPS PDB shall be as specified in Technical specification for Instrument PDB (Doc.ID: 6745-INS-000-EC-0012)
3Following UPS systems complete with all associated equipments such as Battery bank, non integral type ACDB & accessories such as online battery monitoring system, Battery MCCB box, all interconnecting cables between AC UPS, ACDBs, Battery and Battery isolators, battery stand assembly etc. a) UPS-11802 1 ph, 2 wire, 60 kVA, 230 V, 50 Hz, Dual redundant UPS system with ACDB, 2 X 100 % BatteryBank along with cell booster suitable for supplied battery rating b) UPS-11902 1 ph, 2 wire, 40 kVA, 230 V, 50 Hz, Dual redundant UPS system with ACDB, 2 X 100 % BatteryBank along with cell booster suitable for supplied battery rating