Tender For Repair/ Replacement Of Security, Perimeter, Solar Light And Other Connected Work At Af Stn Thoise Under Ge (Af) Thoise, Leh-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair/ Replacement Of Security, Perimeter, Solar Light And Other Connected Work At Af Stn Thoise Under Ge (Af) Thoise. Submission Date for this Tender is 23-05-2023. Solar Light Tenders in Leh Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

37500049
Corrigendum : Tender For Repair/ Replacement Of Security, Perimeter, Solar Light And Other Connected Work At Af Stn Thoise Under Ge (Af) Thoise
Open Tender
Indian
Jammu And Kashmir
Leh
23-05-2023

Tender Details

Repair / Replacement Of Security, Perimeter, Solar Light And Other Connected Work At Af Stn Thoise Under Ge ( Af ) Thoise

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-May-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-05-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 34000.0 /-
Tender Value
INR 17 Lakhs /-

BOQ Items

Name of Work : REPAIR/ REPLACEMENT OF SECURITY, PERIMETER, SOLAR LIGHT & OTHER CONNECTED WORK AT AF STN THOISE UNDER GE (AF) THOISE
Sl. No. Item Description
1M&L for in repair / replacement LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection, including LED lamps of 35 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by Engr-in-Charge.
2M&L for in repair / replacement LED Flood light made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, Potted driver, IP66 protection, including LED lamps of 60 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by Engr-in-Charge.
3M&L for in repair / replacement LED Floodlight made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, Potted driver, IP66 protection, including LED lamps of 120 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by Engr-in-Charge
4M&L for in repair / replacement electronic LED driver for LED light fittings, capacity 45 Watt, 50Hz, complete all as specified and directed by Engineer-In-Charge. Make: Havells/ Wipro/ Phillips
5M&L for in repair / replacement in truly vertical position Steel tubular swaged pole with cast iron base plate finial tapper plug, bolts nuts and screws and specified type 410 SP-31 ( 9 mtr long) in truly vertical position 1.5 m length of pole above ground level shall be painted with two coats of synthetic enamel paint in strips of 30 cm width, black and yellow alternatively and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts complete all as specified and as directed by Engr-in-Charge. Note - (i) Excavation and PCC shall be measured and paid separately (ii) Height of Pole may be trim as per user requirement but specification remain unchanged.
6Excavation in trenches n.exc. 1.5 mtr wide and n.exc 1.5 mtr deep for foundations of poles/stays/cable etc not exc 10 Sqm area on plan and getting out in Hard/Dense soil complete all as specifed and as directed by Engineer-in-Charge.
7Excavating in trenches not exc 1.5 m wide andexc 1.5 m but not 3 m in depth formanholes, sewage line etc not exc 10 sqm on plan and getting out in hard /dense soil.
8Returning filling in including spreading levelling, watering and well ramming in layer each not exc. 25 cm thick in a hard/dense soil complete all as specified and directed by Enginer-in-Charge.
9Removing surplus soil to a distance not exc. 50 mtr and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
10M&L for PCC cable coverClass LV, Type I,flat,size 250 mm x 150mm x 40mm laid Flat in trenches over the cable with length 250mm perpendicular to the direction of cable, adjacent/ abutting each other complete all as specified and as directed by Engr-in-Charge Note:-Excavation and earth work to be measured and paid for separately
11Sand cushioning to protection of underground cables, laid 8 cm before laying and 15 cm after laying of cable, and punned to form an overall layer of 18 cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness of 18cm shall be measured for payment purpose only.
12Plain cement concrete M-7.50 (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
13Plain cement concrete(1:3:6), type C-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
14Plain cement concrete (1:2:4), type B-1 (using 20mm graded crushed stone aggregate), as in coping of poles including necessary form work, finish even and smooth without using extra cement, complete all as specified and as directed by Engineer-In-Charge.
15M&L for in repair / replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16.0 Sqmm, 2-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engr-in-Charge.
16All as per BOQ Srl Item No 15.00 here-in-before but of size cross-sectional area 16.0 Sqmm, 4-core complete all as specified and as directed by Engr-in-Charge
17All as per BOQ Srl Item No 15.00 here-in-before but of size cross-sectional area 185.0 Sqmm, 3.5-core complete all as specified and as directed by Engr-in-Charge.
18All as per BOQ Srl Item No 15.00 here-in-before but of size cross-sectional area 300.0 Sqmm, 3.5-core complete all as specified and as directed by Engr-in-Charge.
19Replacement of old unserviceable/damaged street light bracket made out of GI pipe 40 mm bore medium grade 1.5 m long bend to shape required fixed to pole / wall with MS clamps made out of 40x5 mm, 50 cm long incl nuts bolts of size 80x12 mm complete all as specified and as directed by Engr-in-Charge.
20S& Fin replacementcopper conductor cable 2.50 sqmm PVC insulated two core unsheathed and PVC insulated for conntection ofLED street light fitting from Existing source complete all as specified and as directed by Engr-in-Charge.
21M&L for PVC conduit pipe 20mm dia medium grade for passing through wire between terminal box to street light with GI clamp complete all as specified and as directed by Engr-in-Charge.
22M&L for in repair / replacement of MCB SPN32A C Curve and capacity 16KA with plastic enclosure complete all as specified and as directed by Engr-in-Charge.
23M&L for in repair / replacementfabrication and install street light terminal box outdoor canopy type size 40cm Height x 30 cm width x 12 cm thick size of canopy 30cm x 13 cm complete with locking arrangement, 4 Nos aluminium busbar size 20 x 5mm, 8 Nos nut, bolt, & 8 Nos aluminium cable socket suitable forupto 185 sqmm cable embeded in PCC foundation with 2 Nos angle iron leg 25x25mm 40 cm longas per sample incl taking down complete all as specified and as directed by Engr-in-Charge.
24M&L in repair Earthing complete with copper plate electrode 600x600x3.15mm thick electrode burried directly in ground not less than 3.0 mtr deep below normal ground level with top edge of earth plate not less than 2.5 mtr below normal ground level connected to and including and 20x3 mm copper strip as earth lead by means of bolt ,nuts, check nuts, and washers of stainless steel and duly welded incl PCC pit in PCC 1:2:4 type B-I angle iron 40x40x3mm frame, pit in PCC 1:2:4 type B-I cover 40mm reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, excavation and earth work in any type of soil, charcoal dust and salt light grade GI watering pipe 20mm bore with funnel and wire mashand medium grade GI protectionpipe 40mm boreand earth wire up all as shown in electrical plate No 3 of MES SSR- Part-I all as directed and specified by Engineer-in-charge. Note : (i) Excavation work should be done by manpower only. (ii) Earth test should be done by contractor in presence ofEngr-in-Charge and if required result is not found, entire earthing should re-done by contractor without accruing any extra cost to Government.
25M&Lfor applying two coat of synthetic enemal paint to 9 mtr long steel tubler swaged pole including marking alternate white and black strip painting upto 1.2 height and writing pole no on pole complete all as specified and as directed by Engr-in-Charge.
26M&Lfor applying two coat of synthetic enemal paint to street light terminal box 40cm hieight x 30cm wide x 12 cm depth including grouting angle with smoke gray paint complete all as specified and directed.
27Replacement of old unserviceable/ damaged GI pipe with new GI pipes/ Tubes, "Light grade", galvanised, 50 mm bore, ISI marked, laid in trenches or fixed to walls/ poles with mild steel clamps, nuts, bolts and washers; for protection of electric cable, complete all as specified and as directed by Engr-in-Charge.
28S & Fin replacement Cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor type termination heat shrinkable joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185-300 sqmm, complete all as specified and as directed by Engr-in-Charge. Make: Denson/ M Seal/ Raychem
29S & Fin replacement Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 300 sqmm, complete all as specified and as directed by Engr-in-Charge. Make : Denson/ M Seal/ Raychem
30Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 100 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. Make: Schneider cat part No- LV426167 or equivalent in in L&T/ Legrand/ ABB/ Merlin Gerin/ Siemens.
31M&L for in repair / replacement Change over switch, rating 100 Amps, four poles, 415 Volts, AC, 50 Hz, on load, conforms to IS:13947 (Part-3); IEC:60947-2, side handle, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- IHBFFE0100 or equivalent in Indo-Asian/ L&T/ Legrand/ ABB/ Controls and switchgears/ Merlin Gerin/ Schneider/ Siemens.
32M&L for in repair / replacement Change over switch, rating 200 Amps, four poles, 415 Volts, AC, 50 Hz, off load, conforms to IS:13947 (Part-3); IEC:60947-2, side handle, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- IHBFFE0200 or equivalent in Indo-Asian/ L&T/ Legrand/ Standard/ ABB/ Controls and switchgears/ Merlin Gerin/ Schneider/ Siemens.
33M&L for in repair / replacement Mild steel bands, straps, including bolts, if required: clamps for house brackets for mounting street/ security light fittings; ties; hooks for hanging fans;and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and as directed by Engineer-In-Charge.
34M&L for in repair / replacement Solar Street Light "All in One" of system voltage 12 V of 30 Watt with lumen of >125 with MPPT controller , Mono crystalline SPV Module (WP), Li Fi Battery with 2 days Back up including design pole , fabrication , fixation, and embedded in Plain Cement Concrete M-10 (1:3:6), type C-1 (using 20mm graded crushed stone aggregates) up depth as per manufacturer"s instruction including two years warranty against defects if any arised, complete all as specified and as directed by Engr-in-Charge. Make Havells Cat Part No LHSTAKU7CBAF030 or Equivalent in Crompton and Philips.
35Attanding day to day complaints for maintenance and repair of street/ perimeter security light fittings of any type and any specifications or any accessories related to security light fittings of any descriptions, fitted/ fixed on poles, buildings or watching towers of any heights and any location, and re-fixing the same after necessary repairs/ replacement of defective parts including rectifying the same as per directions by concerned JE E/M and Engineer-In-Charge, at various locations, complete all as specified and directed by Engineer-In-Charge. Note: (i) Cost of T&P, ladder or mechanical lift shall be deemed included in quoted rate. (ii) Supply of spare parts of light fittings shall be measured and paid separately.
36Note: The work under subject BoQ (item No. 1.00 to 35.00 ) is meant for maint of senstive security and street lightin AF Stn Thoiseunder GE(AF) Thoise. The work shall be executed on ground on required basis. Contractor shall deploy sufficient resources to keep smooth working of Security and street lightin the AF station. Contractor or his representative will daily attend the complaints at E/M complaint cell and in addition any breakdown shall be communicated to contractor or his representative by concerned Engineer-in-charge/JE E/M through phone call, text message, complaint slip and or in writing through site order book or through other means. Non complying of attending breakdown by contractor within 24 hours after notify the complaint, recovery @ Rs 1500/- per day shall be recovered from contractor"s payment for each complaint so notified.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail