Tender For Establishment Of Server Room/Data Centre For Irrigation And Water Resource Department Uttar Pradesh Under Nhp, lucknow-Uttar Pradesh

Uptron Powertronics Limited-UPL has published Tender For Establishment Of Server Room/Data Centre For Irrigation And Water Resource Department Uttar Pradesh Under Nhp. Submission Date for this Tender is 10-05-2023. Computer Server Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

37485416
Tender For Establishment Of Server Room/Data Centre For Irrigation And Water Resource Department Uttar Pradesh Under Nhp
Limitted
Indian
Uttar Pradesh
lucknow
10-05-2023

Tender Details

Establishment Of Server Room / Data Centre For Irrigation And Water Resource Department Uttar Pradesh Under Nhp => Limited

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work :Establishment of Server Room/Data Centre for Irrigation and Water Resource Department Uttar Pradesh under NHP.
Sl. No. Item Description
1Shifting from old data center to new proposed server room @ Parikalp Bhawan packing and set up of Communication Item like server, server rack, Computer, UPS, CPU and other items as furniture, electronics, Genset etc , all the material stacked, installed as per direction of engineer in charge
2Checking and setting up of servers including installation of different apps of department on the server for users use
3Providing and fixing 15 mm thickfalse ceiling tilesat all heights with integral densified calcium silicate reinforced with fiber and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level on the existing frame work consisting of T-sections and L sections suitably fixed according to tile size as per direction of Engineer-in-charge
4Dismantling aluminum/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
5Supply and fixing of firefighting equipment HFC 236fa with capacity of 4 kg
6Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colors and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.The tiles should same as existing flooring Size of Tile 600x600 mm Lumpsum Quantity 15 % of area =15 % of 133.96= 20.094 say 20.1 sqm
7Dislocate of existing partition wall with pedestal by proper stacking as per direction of Engineer in Charge
8Fixing of dislocated partition wall at central flood control room including all accessories and finishing as per direction of engineer in charge
9Providing and fixing workstation table with pedestal unit with ply board of thickness 19 mm, 1 mm thick laminate finish on both side and edges should be finished with 19 mm thick PVC edge banding tape on partition wall
10Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One or more coats on old work
11Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
12Relocate of fan installed at FMISC hall by taking off and refixing with all accessories along with electrical work in different rooms of FMISC office
13providing and fixing of closed valve by cutting and jointing of existing firefighting sprinkler pipe with all accessories as per direction of engineer- in charge
14providing and fixing of Toughened glass 12 mm thickness of approved brand and manufacture complete as per direction of Engineer-in-charge
15Providing and fixing of 18 (12+6) mm ply board with all accessories and complete as per direction of Engineer-in Charge
16Providing and fixing of 1.25 mm thick laminate with 4mm groove finished with filler of matching shade all accessories and complete as per direction of Engineer-in Charge
17Providing and fixing of 75*19 mm Ply board in base framing @ 600C/C with all accessories and complete as per direction of Engineer-in Charge
18providing and fixing 06 module plate with 02 nos of 16 Amp switches and 02 nos of 16 Amp socket along with 03 nos electric cables of ISI mark (phase, neutral and earthing) of 1.5 sqmm wire on the partition wall and other places of room
19Uninstallation of existing LAN/Network cable stacking as per direction of Engineer in Charge
20Providing and laying LAN /Network Cable with protection of plastic strip with required network switches as per direction engineer in charge
21Providing, laying and connection of electric cables of ISI mark to switches from UPS room to server room with essential protection of Plastic strip required size as per direction of engineer in charge
22Providing and fixing RFID (radio frequency identification) smart card-based access control system (ACS) with biometric Reader Integration for Regulating and Monitoring entry and exit of Departmental Employees, Visitors in main entrances of server room with all accessory
23Supply and installation of VRV AC 02 Ton Cassette type of 02 units with one outdoor unit
24Supply and installation of cooling system Split AC of 02 Ton capacity
25Temperature monitoring unit with display
26relocate of existing CCTV camera from proposed Server room to other place of FMISC office with all accessories as per direction of Engineer-in Charge
27Providing and installation of CCTV camera 04 Megapixel of dome type varifocal camera 04 nos with high speed 08 channel DVR with 2 SATA supported and 04 TB HDD for storage at server room
28Providing and fixing LED false ceiling light size of 595 mm*595 mm of 40 watts cool white 100 LM/W
29Providing and fixing strip LED light 28 watt cool white at server room
30providing and fixing of floor carpet of 100% Nylon or equivalent nylon with soil resistant treatment thickness of 8 mm
31Providing and fixing smog detector alarm system having 04 nos of detecting unit, 02 nos of alarm with one controlling panel fixing with all accessories at server room
32Connection to UPS Room