Tender For Provision Of Cooling Appliances Electrical Wiring Lightening And Misc Electrical Services For Casu Cgrpt And Cgds Building At Paradip, paradip-Odisha

Military Engineer Services-MES has published Tender For Provision Of Cooling Appliances Electrical Wiring Lightening And Misc Electrical Services For Casu Cgrpt And Cgds Building At Paradip. Submission Date for this Tender is 29-05-2023. Electrification Work Tenders in paradip Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

37484636
Corrigendum : Tender For Provision Of Cooling Appliances Electrical Wiring Lightening And Misc Electrical Services For Casu Cgrpt And Cgds Building At Paradip
Open Tender
Indian
Odisha
paradip
29-05-2023

Tender Details

Provision Of Cooling Appliances Electrical Wiring Lightening And Misc Electrical Services For Casu Cgrpt And Cgds Building At Paradip

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-May-2023 Corrigendum No 1 Other 22-05-2023
2 22-May-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 29-05-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 71900.0 /-
Tender Value
INR 35.95 Lakhs /-

BOQ Items

Name of Work: PROVISION OF COOLING APPLIANCES, ELECTRICAL WIRING, LIGHTENING & MISC ELECTRICAL SERVICES FOR CASU, CGRPT & CGDS BUILDING AT PARADIP UNDER GE (I) (CG) BHUBANESWAR
Sl. No. Item Description
1SCH "A" PART-I (INTERNAL ELECTRIFICATION) S&F Call Bell ,Ding-Dong ,single pole, AC, 230 Volts complete all as specified and directed. Make:- Anchor/Cona/Havells.
2Supply and fixing in repair single pole and neutral sheet metal enclosure box including metallic two pin Plug and socket with 20 Amps MCB (SPN) "C" seriescomplete all as specified and directed.
3M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable of size 2 x 4.0 Sqmmand earth continuity conductor of size 1 x 4.0 Sqmm to be drawn into PVC conduit conceald wiring complete all as specified and directed.
4M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable of size 2 x 6.0 Sqmmand earth continuity conductor of size 1 x 6.0 Sqmm to be drawn into PVC conduit conceald wiring complete all as specified and directed.
5Supply and fix heavy duty exhaust fan of 300 MM sweep,Turbo Force SP (Heavy duty ) single phase 230/240 Volts,, AC supply, 1400 RPM complete and making holes with louvered shutters including mounting frame and connecting the fan to celing rose including provision of three core flexible copper conductor cable of size 1.5 Sqmm copper including to inside out surface & white wash etc with not less than 0.5m long to connection complete all as specified and directed. Make-Havells/Usha/Khaitan/Orient
6M&L earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on complete all as specified and directed.
7M&L 4mm dia galvanised iron or steel wire for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drwan in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc.as requiredcomplete all as specified and directed.
8M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable of size 4 x 10.0 Sqmmand earth continuity conductor of size 1 x 10.0 Sqmm to be drawn into PVC conduit conceald wiring complete all as specified and directed.
9Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete all as specified and directed.
10Supply and fixing of MCB DB double door, made of sheet steel phosphates, powder painted with bus bar, neutral link, earth bar and din rail SPN 8 way with 200 Amps rated bus bar 240 Volts including taking down complete all as specified and directed.
11Supply and fixing of MCB DB double door, made of sheet steel phosphates, powder painted with bus bar, neutral link, earth bar and din rail SPN 12 way with 200 Amps rated bus bar 240 Volts including taking down complete all as specified and directed.
12M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable of size 2 x 1.5 Sqmmand earth continuity conductor of size 1 x 1.5 Sqmm to be drawn into PVC conduit conceald wiring complete all as specified and directed.
13Supply & fix watt LED tube light along with fixture, 20 W LED 6500 k extruded aluminium channel/bodycomplete all as specified and directed. ( Make/Model No: PRIDE PLUS SPECTRA , LHEXARP7IN1W020of havellsor equivalent ofBajaj/Phillips/crompton )
14Taking down carefully copper/aluminium point wiring including sunken M S Boxes (Light, Fan, socket or power) complete,(fitting such as switches,ceiling roses,call bell,pendants,regulators,socket etc by unscrewing from board carefully and making good disturbed surfaces of walls,floors etc complete all as specified and directed.
15M&L for point wiring with PVC insulated unsheathed stranded FRLS copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded FRLS copper conductor cable of size 1.5 Sqmm for earth continuity wire, to be drawn in and including PVC conduit heavy duty with concealed wiring, MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thickswitch board and brass screws with cap washers for one light/Fan point controlled by one single way switch including all necessarywall cutting and making good disturbed surfacecomplete all as specified and directed. (Make of wire: Finolex/Polycab/Plaza Make of PVC Conduit :-Plaza/Prestoplast/Precision)
16M&L Point wiring for one light point or one fan point controlled by one switchwith two runs of FRLS grade PVC insulated unsheathed stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLS grade PVC insulated unsheathed strandedcopper conductor asfor earth continuity wire to be drawn in and including PVC casing & caping ( medium grade) not less than 25 mm width with fittings & fixtures includingMS sheet metal switch / terminal box 1.22 mm thick upto(200x300)mm size duly covered with backelite sheet cover 3.00mm thick and continutiy conductor shall be connected to common earth and earth dolly and makinggood disturbed surface to walls complete all as specified & directed . (Make of wire: Finolex/Polycab/PlazaMake of PVC Casing-N- Caping :-Plaza/Prestoplast/Precision)
17All as per here and before item No-16 above but Concealed wiringin Existing Conduit .
18All as per here and before item No-16 above but for one light point controlled by one two way switch
19All as per item No. 16 above but for call bellpoint.
20All as per item No. 16 above but for Same board 5 Amps switchsocket out let using 1.5 Sq mm wire with 1.5 Sqmm wire for earth continuity conductor.
21All as per item No. 16 above but for independent 5 Amps switchsocket out let using 1.5 Sq mm wire with 1.5 Sqmm wire for earth continuity conductor.
22All as per item No. 16 above but for 5/15 Amps switch point socket out let using 2.5 Sqmm wire with 2.5 Sqmm wire for earth continuity conductor on independent board.
23Supply and fixing including connection of modular switch one way 6 Amps 1 Module complete all as specified and directed.
24Supply and fixing including connection of modular switch one way 16 Amps 1 Module complete all as specified and directed.
25Supply and fixing modular Bell push 6A 1 Module complete all as specified and directed.
26Supply & fixing including connection modular Switch socket combination 2 in 1,5 pin 5 amps 3 modules complete all as specified and directed.
27Supply & fixing including connection modular Switch socket combination 2 in 1,6 pin 16 amps 3 modulescomplete all as specified and directed.
28Supply & fixing including connection modularsocket outlet2 /3 pin 6 Amps 2 modules complete all as specified and directed.
29Supply & fixing including connection modularSocket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
30Supply and fixing of Modular Fanregulator,120 watts complete all as specified and directed.
31Supply and fixing white modular cover plate with frame 1 Module complete all as specified and directed.
32Supply and fixing white modular cover plate with frame 2 Module complete all as specified and directed.
33Supply and fixing white modular cover plate with frame 3 Module complete all as specified and directed.
34Supply and fixing white modular cover plate with frame 4 Module complete all as specified and directed.
35Supply and fixing white modular cover plate with frame 6 Module complete all as specified and directed.
36Supply and fixing modular metal flush box 1/2 Module complete all as specified and directed.
37Supply and fixing modular metal flush box 3 Module complete all as specified and directed.
38Supply and fixing modular metal flush box 4 Module complete all as specified and directed.
39Supply and fixing modular metal flush box 6 Module complete all as specified and directed.
40Supply and fixing of ceilings rose of PVC polycarbonate isolated body three terminals complete all as specified and directed.
41Taking down unserviceable sub main /Sub circuit wiring of any type and size including conduit, batten wiring for necessary repair/replacement complete all as specified and directed.
42Supply and fixingof Round surface mounted LEDSlim panel of capacity 12 watt PDC white finish aluminiumhousing with high translucent frosted plastic diffuser of robust Luminaire with efficacy of 100lm/w complete all as specified and directed. ( Make/Model No:-LCDSPLN-R-12-CDL(PEARL NIOS-R) of Cromptonor equivalent ofPhillips/Havells/ Bajaj/C&S))
43Taking down Old unserviceable DBs Box complete all as specified and directed.
44Supply and fixing of VTPN DB double door,IK 09,IP43-Metal door, 4 way, made of CRCAsheet steel ,RAL 9003,powder coated with bus bar, neutral link, earth bar withprovision forDU125A MCCB,4 pole as incomer and SP/TP MCBs as Outgoings, including taking down old one complete all as specified and directed. ( Make/Model- DBVTL004DD of L&T or Equivalent of HPL/Legrand/Havells/C&S
45S&F MCCB 4 pole,100 Amps, for Incomer of VTPN with fixed thermal & magnetic release of breaking capacity 30kA,DU100H(Icu=30kA,Ics=50% Icu), 415 Volts complete all as specified and directed. (Make: L&T,Cat No.CM97933OOK2 or Standard/ HPL/Havells/C&S)
46S & F MCB 40 Amps SP `C" series, complete all as specified and directed. Make:L&T,,Cat No-BB10400C or Standard/Legrand/HPL./Havells/C&S
47S & F MCB 06 to 32 Amps SP `C` series, complete all as specified and directed. Make:L&T,Cat No-BB 10320C or Standard/Legrand/HPL/Havells/C&S
48S & F MCB 06 to 32 Amps SPN `C` series, complete all as specified and directed. Make:L&T,Cat No-BB20320C or Standard/Legrand/HPL/Havells/C&S
49Supply and fixingofSurface mountedLED 18 WFull lit 1ftx1ftluminiarecomplete all as specified and directed. Make/Model No:POLARIS NIO -III , LCTLSNE 18-CDL of crompton or equivalent ofWipro/Phillips/havells
50SCH "A" PART-II (COOLING APPLIANCES) M&L for point wiring with PVC insulated unsheathed stranded FRLS copper conductor cable of size 2.5 Sqmm, with PVC insulated unsheathed stranded FRLS copper conductor cable of size 2.5 Sqmm for earth continuity wire, to be drawn in and including Existing Conduit with concealed wiring, MS sheet metal and for 15 Amps switch point socket out let on independent board. point controlled by one single way switch including all necessary Complete allas directed and specified.(Make of wire: Finolex/Polycab/Plaza Make of PVC Conduit :-Plaza/Prestoplast/Precision)
51Supply and installation, commissioning of Water cooler fully stainless steel, 60/120 ltr Capacity electric driven (single phase) 240 Volt, 50Hzhaving approx storage Capacity 120 Ltrs and nominal cooling Capacity of 60 Ltrs per hour Complete all as specified and directed. Make: Voltas, Blue Star & Usha
52Supply and Install Voltage stabilizer copper winded for automatic operation, single phase naturally air cooled indoor type Wall mounted type & designed for input variation between 90 V to 230 Volt with out put voltage stablized at 230V with accuracy of +- 2.5% and capacity of 5 KVA Complete all as specified and directed Make:V Guard, Microtac & Blue Line
53Supply and fix R O With RO+UV+UF+TDS controlor Sedment+Carbn & Pump with Pre- sediment filter set, pipe line and complete all accessories of out put capacity of 25 Litres per hourcomplete all as sepecified and directed . (Make:-Kent model Elite1/Voltas/ LG/Samsung
54SCH "A" PART-III (EXTERNAL ELECTRIFICATION) Supply & fix AC Three phase static energy meter of accuracy class 1.0 ,3 X 240 V ,50 Hz with Backlit LCD display of rating 10 - 60 A (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical ommunication port display in absence of power with transparent hingetype box complete all as specified and directed.
55M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal groundlevel connectedto galvanised iron strip 25×4mm as earthing lead by means of check nuts and washer of galvanized iron or steel including40 mm dia GI pipe light grade upto 1.5 mtr below ground level for protection pipe ,excavation and earth work charcole dust, common salt PCC 1:3:6 type C-I using 20 mmstone aggregate forchamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handle 12 mm dia, round ,PGIfunnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate no 3 of SSR Part I of 2009and connected to earth test point incl testing complete all as specified anddirected . Note :- Cost of earthing strip & GI pipe 25mm up to 7.5 m shall be included in cost of above item.
56Supply installation testing and commissiong of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control AMF panel having meter and sound proof canopy as per CPCB norms and foundation as per site requirement etc. of capacity20 KVA complete all as specified and directed.
57A) DIESEL ENGINE: - diesel engines turbocharged with after cooler, electric start, compression ignition, 4 stroke, designed to run continuously at 1500 RPM confirming to IS 10002, ISO-3046, BS 5514 standard with an overloadcapacity of 10 % for one hour in every 12 hrs operation. Diesel Engine will comply with present CPCB-II norms. The diesel engine will comprise of following: - (a) Radiator with Fan (b) Fuel pump with Electronic Governor (c) Dry type air cleaner (d) Exhaust Silencers (e) Lub Oil filters (Spin On Type) (f)Fuel Oil filter (Spin On Type with Pre & Micro filter) (g) 12V Electric starting system (h)Battery charging alternator (j)Stop solenoid (k) Lub Oil pressure gauge (l) Water temp. Gauge (m)Lub oil temperature gauge (n) Ammeter battery charging (o)K - Cool Super Plus coolant (p) First Fill of Lube oil
58B) ALTERNATOR:- Alternator suitable for 20 KVA output with min 16 kw rating suitable for continuous operation rated at 1500 rpm 415 V, 0.8 PF, 50Hz, 3 Ph. in SPDP enclosure, self- excited & self- regulated, Brush less, floor mounted with Ball or Bearings on end shields. The alternator conforms to IS: 4722, BS EN 60034-1 & will be suitable for tropical condition. C) BASE FRAME: - Suitable to couple above Engine & Alternator made from steel sheet metal. D) FUEL TANK: - 10 Hrs Capacity, with Inlet & Outlet arrangement, air vent & drain plug arrangement.complete all as specified and directed. MAKE- Engine- Kirloskar,cummins, greaves -cotton Alternator- kirloskar,stamford,jyoti,crompton greaves,alstom,areva, DG set with canopy- kiloskar,sudhir,cummins india, greaves cottonNote- 1.The scope includes load testing by MES rep/testing officer and includes necessary load bank for testing , FOL and otheritems in presence of OEM rep2. the scope includes necessary connection of DG setto LT panel in complete .
59Supply and laying of GI tubing light grade 40 mm with all fittings laidin trenches/road crossing/along the pole for protection of cable including taking out old GI tubing and making surface in condition complete all as specified and directed. (Make:- Jindal/Prakash/Tata)
60Supply and laying of GI tubing light grade 50 mm with all fittings laid in trenches/road crossing/along the pole for protection of cable including taking out old GI tubing and making surface in good codition complete all as specified and directed.
61Supply and laying cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm x 4.0 corecomplete all as specified and directed.
62Supply & laying ofcable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volt grade with stranded aluminium conductor of size 25 Sqmm 3.5 Core complete all as specified and directed.
63Supply & fixing LED street light fitting 90 Watt RAPTOR PRO- II street light are aerodynamically designed for all weather conditions with wxccellent thermal management made up of pressure die cast housing with toughened glass and high power LEDs with secondary optics and IP66 protection efficacy >- 110/125/135 LPW, 10KV SPD Included complete all as specified and directed. (Make/ Model:- Crompton(NEW RAPTOR PRO-II), Cat No . CRP-411-90-57-SL-LM-NSR or equivalent make of Phillips/Wipro/Havells)
64M & L Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and l02mm x 279mm at bottom, class 10 complete all as specified and directed
65M&Lfor cement concrete type C2 1:3:6 using 40 mm graded aggregate complete for foundation bedcomplete all as specified and directed.
66M&L providingfor cement concrete in foundations, filling and mass concrete type D2 1:4:8 using 40 mm graded aggregate complete for filling mass concrete for polecomplete all as specified and directed
67M&L for cement concretetype B1 1:2:4 using 20 mm graded aggregate complete for pole Copingcomplete all as specified and directed
68M & L of MS Clamp of flat iron size 50x6 mm complete with nut, bolt, washers complete all as specified and directed.
69Excavation in trenches not exc 1.5m deep and n.exc 1.5m wide and getting out in soft/loose soil for laying of cable and foundation of Pole complete all as specified and directed.
70All as per item No-67 above but for each additional 1.5 mtrin depth beyond the first 1.5mtr complete all as specified and directed.
71M&L for sand coushioning with dry and clean over and under the cable for protection of cable , 180 mm sand laid before laying the cable & 150 mm sand after laying the cable and filling the sand in cable duct inside the sub station building complete all as specified and directed.
72Returning, filling in, including spreading, leveling watering and well ramming in layer not exceeding 25 Cm complete all as specified and directed.
73Removing of excavated material not exceeding 50 m and depositing where directed at level not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed.
74M&L for laying of bricks locally available sub class "B" bricks (old size) for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cablecomplete all as specified and directed.
75Cutting Bituminous road in,making good withfacing where required and pointingexc.30 cm. but not exc.1.0 mtr. girth to ends or edges of landing, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring,laying of cables and making good with old shape and size complete all as specified and directed.
76Supply and fixing in repair of GI pipe Bracket of 40 mm dia light grade pipe bend to shape of approx length 1.5 Mtr including 2 no. MS Clamp of flat iron size 40x6 mm complete with nut, bolt, washers complete all as specified and directed.
77Supply & Fixing repairs cable junction box made of thermoplastic, halogen free, weather proof with metric Knock outs for cable entry including four/five pole terminals and cable entry glands for incomming, out going and connection cable with protection grade IP-66/67 of size 205x255x112 mm and suitable for LT under ground cable any size/capacity including bracing clamp,bolts,nuts & washers complete all as specified and directed.
78Supply, Installation, testing and commissioningof Timelite DB ,32 Amps,3 Pole, 230 Volts,Indoor/Wall mounted type, Consisting withAstronomicalTime Switch Make/Model- INDOASIAN/TDA45163,Astronomical Programmable every 1 minute,backup of 6 years,28 memory locations, Current capacity 16 A, with 1 Changeover( 1CO ),total 28 programmes with complete accessories complete all as specified and directed. Make/Model- INDOASIAN, Cat No-TL032AS0 or Equivalent of L&T/SECURE/LEGREND.
79Supply,install,testing & commissioning in repairLT Panel board , outdoor type, floor mounted, CRCA, made of sheet steel ,factory made suitable for 415 volt, 3 Ph4 wire, 50 HZ, AC supply systemof size not less than 1500 mm x 1200mm x 500 mm,open on both back and front side having hinges and locking arrangements having busbars chamber with Aluminium bus bars with vertically arranged of 600 Amps rating duly insulated by insulation of RYB colour mounted on porcelain insulators .The panels shall be made out of 3 mm thick CRCA Sheet , powder coated based on MS channel for arrangement of foundation nuts , bolts and washers (Make:Universal Switch gear control/C&S/Neptune/Power system & Control). The Panel should be protected with IP 54 in accordance with IEC 60529. The gasket material shall be polyurethane,whilethe material shall beinternally embedded. the Panel should beincluding with internal wiring with multistranded copper conductor cable of suitable size includinglugs and cable gland to incoming and outgoing cable etc and supported on MS angle of size not less than 450 mm long, LED indicating lamps, current transformers, terminal block for cables and including making of suitable size foundations as per manufacturer recommendations and taking down old unserviceable panel /fidder pillars alongwith all accessoriescomplete all as specified and directed at site and to incorporate the following:-
80Note : (i) Existingall connectionsto be disconnected from old Panel and reconnected to New Panel complete testing and commissioning etc with all other connected civil works to be included in quoted rate.
81(A) IN COMING (i)MCCB four pole 415 Volts AC Supply,DU400N, 400 Amps, 50kA,thermal magnetic release type -01 No with Rotary handle and seperator link Make:- L&T,Cat No:- CM98404OORO or equivalent in Legrand/C&S. (ii) Panel mounted multi function meter Consiting of Volt meter for measuring Voltage (0-500 Volts), Ampere meter for measuring Current(0-500 Amps) and Frequency meter of 50Hz and PF Meters- 01 No.Make-L&T,Cat No-WL411011OOOO or equivalent. (iii) Panel mounted Onload Change Over Switch ,Manual Open executiontype,415 volts,4 pole,400 Amps,,type-CO4-400 - 01 Nos, Make:- L&T,Cat No:- CO44000OOOOor equivalent of Legrand/C&S
82(B) OUT GOING (i)MCCB 4 Pole 415 Volts DU125H,30 kA125 Amp .rating thermal magnetic release type- 04 Nos, Make:- L&T,Cat No:- CM90679OOLOor equivalent of Legrand/C&S (ii)MCCB 4 Pole 415 Volts ,DU100H, 30 kA 63 Amp rating thermal magnetic release type-03 Nos, Make:- L&T,Cat No:- CM97933OOH2or equivalent of Legrand/Schneider Note :- All MCCBs should be with rotary handle.
83SCH "A" PART-IV (EXTERNAL WATER SUPPLY) Taking down old Rusted GI Pipe and Supply and Laying GI pipe medium grade with allfittings and clamps laid in trench/Wall/floor all as specified and directed of the Size 50 mm bore of pipe complete all as specified and directed.
84Taking down old unserviceable Gate valve and Supply and fixgun metal gate valve size 50 mm bore with iron wheel complete all as specified and directed.
85Taking down old unserviceable Union of 50mm dia and Supply and fixUnion size 50 mm bore Both ends screwed to iron pipes, or one flange end bedded in red lead cement,and other end crewed to iron pipe, etc. complete all as specified and directed.
86Taking down old unserviceable Submersible Pump and Supply and fixHorizontal Openwell Submersible Pump Set,3 HP,440 volts,3 Phase,Suction x Delivery ( 50mm x 50mm )head range 18-27mtr, discharge 590 ltr/min complete all as specified and directed.Make-Crompton,Cat No- OWN32 or equivalent of KIRLOSKAR/RYKER/ALGO
87Taking down old unserviceable DOL Starter and Supply and fix DOL Starter,3 HP,3 Phase,415 volts,50 Hz complete all as specified and directed. Make-Crompton,Cat No- DOL 4065-2S3M or equivalent of L&T/Siemens.
88Supply and fix Cold water flow meter, flanged end type,line size-50mm for Industrial use complete all as specified and directed. Make- Woltman or equivalent of Kranti/HBMG/Alibaba.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy