| 1 | Excavation in trenches in soft/loose soil, n. exc 1.5 m wide and n. exc 1.5 m in depth for foundation, laying of underground cable etc or n. exc 10 Sqm on plan and n. exc 1.5 m in depth for foundations of poles, struts, stays etc.& getting out including trimming the sides and forming bottom surfaces to required level complete all as specified and directed. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in soft/loose soil complete all as specified and directed. |
| 3 | Removal of excavated surplus (soils) to a distance n.exc 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed. |
| 4 | M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm) shall be considered for measurement and payment. |
| 5 | Supplying and laying,factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dryin trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed. |
| 6 | Material & labour, for cutting existing road for taking out/laying of underground cable through GI pipe of dia 40mm/80mm including necessary earth work and making good to match with the existing surface with PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) complete all as specified and directed |
| 7 | Supply and laying / fixing , GI pipe, light grade, 40mm bore for cable protection fixed to pole/wall with MS clamps, nuts, bolts etc or laid under floor/road/pavement complete all as specified and directed.Note: (i) Excavation and earth work shall be measured and paid separately. |
| 8 | Supply and laying / fixing , GI pipe, light grade, 80mm bore for cable protection fixed to pole/wall with MS clamps, nuts, bolts etc or laid under floor/road/pavement complete all as specified and directed.Note: (i) Excavation and earth work shall be measured and paid separately. |
| 9 | Disconnecting & taking out defective under ground cable of any size from trenches, pole, pipe, floor, wall etc and removing from site completeall as specified and directed. |
| 10 | Supply, laying, jointing, testing and commissioning of Low Tension (LT)XLPEinsulated,armoured, heavy duty, electric power cable, cross sectional area 10 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, alongpolesorpassing through pipes or laid under floor or through walls etc, completeall as specified and as directed. Note:(i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately. |
| 11 | All as per Ser item No 10 here-in-before but LT cable of cross sectional area16 Sqmm, 4 core |
| 12 | All as per Ser item No 10 here-in-before but LT cable of cross sectional area35 Sqmm, 3.5 core |
| 13 | All as per Ser item No 10 here-in-before but LT cable of cross sectional area 50 Sqmm, 3.5 core |
| 14 | All as per Ser item No 10 here-in-before but LT cable of cross sectional area70 Sqmm, 3.5 core |
| 15 | All as per Ser item No 10 here-in-before but LT cable of cross sectional area95 Sqmm, 3.5 core |
| 16 | All as per Ser item No 10 here-in-before but LT cable of cross sectional area150 Sqmm, 3.5 core |
| 17 | All as per Ser item No 10 here-in-before but LT cable of cross sectional area240 Sqmm, 3.5 core |
| 18 | All as per Ser item No 10 here-in-before but LT cable of cross sectional area10 Sqmm, 2 core |
| 19 | S&F in replacement twin core cable, 10 sqmm,nominal cross sectional area, multi-stranded, aluminium conductor cable, over all PVC sheathed, 1100 volts grade, heavy duty , PVC insulatedcomplete all as specified and directed |
| 20 | S&F in replacement twin core cable, 16 sqmm,nominal cross sectional area, multi-stranded, aluminium conductor cable, over all PVC sheathed, 1100 volts grade, heavy duty , PVC insulatedcomplete all as specified and directed |
| 21 | Disconnecting, dismantling and taking down carefully ACSR conductor ofany size from poles of LT/HTcomplete all as specified and directed. |
| 22 | S&F Aluminium conductor steel reinforced (ACSR), stretched on HT/LT poles without any kink and bends, of various sizes complete including fixing to insulator with aluminium binding wire and coloured sleeved jumper connection with PG clamps including cutting of tree branches falling on the site of work complete all as specified and directed .Note: The size of conductor shall be as directed by Engr-in- Charge. |
| 23 | S&F in replacement shackle type,vitreous, porcelain white, brown or green insulator for working pressure 1100 volts,height 75 mm and dia 90 mmincluding galvanized mild steel straps of 31mm x 3mm size,12mm dia insulator bolts, washers and nuts complete all as specified and directed |
| 24 | S&F in replacement pin type,porcelain, vitreous, white, brown or green insulator of 100mm height, 65 mm dia,suitable for 1100 volt grade including one galvanized mild steel spindle, two GI washers and one GI nutcomplete all as specified and directed |
| 25 | Disconnecting faulty LT cables of any size from both ends,detecting fault by fault detecting machine,remove the defect,reconnecting and testing of cable including excavation,returning filling ,removal of earth & relaying of cable protection cover completeall as specified and directed.Note : (i)LT cable & cable joints shall be measured and paid separately under respective items of BoQ.(ii) Contractor\"s rep alongwith Manpower and earth fault locating machine, required to attend the breakdown within one hour of notification by JE(E/M) and contractor\"s quoted rate shall be deemed to include the same. |
| 26 | Dismantling and taking down old cross arms, clamps, braces, brackets of MS channel or angle section including nut boltswashers etc from polescomplete all as specified and directed.Note : Cost of cutting of bolts (slag bolts) if reqd shall be deemed to be included in the unit rate quoted for this item. |
| 27 | S&F Cross arms, bracing, supports, clamps and back plates, fabricated from structural steel section Fe-290 grade E-165 quality including nuts, bolts, washers, and welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. |
| 28 | Re- streching, ofexisting sagged/brokenearth wire and over head ACSR conductor, any size upto 5 conductors in one span of HT/LT over head line to maintain proper sag and bindingwith the existing insulators with new binding wire complete all as specified and directed.Note : (i) Linear length centre to centre of the pole shall only be measured.(ii) 4/5 Lines of ACSR Conductor shall be considered as one span for measurement . |
| 29 | Cutting/ trimming of tree branches not exc 30cm girth,sapling,shrubs etctouching/approaching the LT/HT overhead lines upto 3 metre width on each side with hacksaw/axe to clear the LT/HT line including disposal of trimmed branches 100 Metre away inside the cantonment area & clearing site complete all as specified and directed |
| 30 | M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, buried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to electrical equipment/GOD/LA and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI medium grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of precast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Schedule Part-I (2009), complete all as specified and directed. Note(s):- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with TMT bar 8mm dia both ways @100c/c.(ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) Quoted lump sum / rate shall be inclusive of above all provisions. |
| 31 | M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, buried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including GI strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to electrical equipment/GOD/LA and protected by galvanized iron pipe light grade 40mm dia bore including watering pipe 20mm dia bore GI medium grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of precast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Schedule Part-I (2009), complete all as specified and directed. Note(s):- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with TMT bar 8mm dia both ways @100c/c. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) Quoted lump sum / rate shall be inclusive of above all provisions. |
| 32 | S&F in replacement pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998, errecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in black and white colour upto 1.5 metre height from top of PCC pedestal/coping of poles and numbering of poles with synthetic enamel paint black in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed |
| 33 | S&F in replacementStay assembly comprising of 7/8 SWG galvanised stay strand complete with GI stay rod 16mm dia ,mild steel stay plate, stay bow,connecting bracket of suitable mild steel flat , nuts, bolts, washers,loop type insulatorsetc complete all as specified in electrical plate No I of SSR-2009 (Part- I) complete all as specified and directed..Note:- Excavation and earth work , PCC shall be measured and paid separately under relevant items of BoQ’. |
| 34 | M&L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in foundation,filling & mass concrete complete all as specified and directed |
| 35 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates) as in coping of poles etcincluding weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed |
| 36 | Demolition of concrete (un-reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and directed |
| 37 | Repair of LT panel by welding broken lid including all material required to make LT panel fuctional including providing new hinges & new locking arrangement (front and back side) and fixing by welding complete all as specified and directed |
| 38 | Surface dressing not exc 15cm deep in soft/ loose soil including cleaning of E/M installations premises, uprooting of tiny trees, tree cutting, cleaning, levelling, spreading bushes, beeds, grass, removing poly bags, brick bats, stone pebbles debries, cleaning of sub station bldg, two pole/ four pole structure area, HT line etc and removing to a distance not exc 50 Mtr complete all as specified and directed |
| 39 | M&L for painting to steel tubular poles upto 9metre long including attachments (cross arms, clamps, GI pipes etc) complete with two coat of aluminium paint after scraching out old paint, cleaning the existing surface for rust free & preparing of the existing surface for paintingincluding marking pole numbers in a 15 cm dia yellow circle with number writting with black syenthic paint/ Stricker includingpainting strips in alternate from bottom to top with three strips of white synthetic enamel paint & two strips of Yellow/ black paint(as per existing pattern) through out the circumference of pole andapplying one coat of white washing on PCC copping of pole after preparing the existing surfaces complete all as specified and directed. |
| 40 | M&L for painting with two coat of cement base paint (white ) on LT PCC pole including painting strips in alternate from bottom to top with three strips of white synthetic enamel paint& two strips of Yellow/ black paint (as per existing pattern) throughout the circumference of pole including one coat of lime wash on PCC copping of polewith and painting with two coat ofaluminium paint to channels, cross arm, clamps and pipes fixed/ mounted on LT pole after scraching out old paint, cleaning and making existing surface rust freecomplete all as specified and directed. |
| 41 | Disconnecting faulty/burnt end or portion of cable from LT panel/LT pole/ main switch/change over etc ,removing burnt/faulty portion of cable,pulling out cable from loop after necessary excavation & earth work , preparing fresh terminals, cleaning the surface not less than 01 metre surrounding panel/pole,providing thimbles of suitable size, LT tape,relaying &reconnecting the cable of any size and testing of cablecompleteall as specified and directed. |
| 42 | M&L for cutting LT cable armoured ends, burn out old lugs, any size and specification, preparing ends for connecting cable end aluminium tube terminals / lugs & dressing, crimping of 25 Sqmm to 35 Sqmm with MS nut bolts and washers of suitable size complete all as specified and directed. |
| 43 | All as per Ser item No 42 here-in-before but of Size 50 Sqmm to 70 Sqmm |
| 44 | All as per Ser item No 42 here-in-before but ofSize 95 Sqmm to 120 Sqmm |
| 45 | All as per Ser item No 42 here-in-before but of Size 150 Sqmm to 185 Sqmm |
| 46 | All as per Ser item No 42 here-in-before but of Size 240 Sqmm to 300 Sqmm |
| 47 | Supplying, jointing and testing in replacement ofstraight through jointing kit ,heat shrinkable typesuitable for3.5 core XLPE cable of size 35 to 70 sqmmcomplete all as specified and directed. |
| 48 | Supplying, jointing and testing in replacement ofstraight through jointing kit ,heat shrinkable typesuitable for3.5 core XLPE cable of size 95 to 150 sqmmcomplete all as specified and directed. |
| 49 | Supplying, jointing and testing in replacement ofstraight through jointing kit ,heat shrinkable typesuitable for3.5 core XLPE cable of size 185 to 300 sqmmcomplete all as specified and directed. |
| 50 | Supplying, jointing and testing in replacement ofheat shrinkable typeend termination cable jointing kit, outdoor type, suitable for 11KVunder ground earthed system 3.0 core XLPE cable of size 95 sqmmincluding making connectionsand taking out old u/s joint complete all as specified and directed. |
| 51 | S&F in replacementMCCB, 4 pole, 415 volt, 400 Amp,breaking capacity 36 KA,Icu-100% Ics with adjustable thermal and fixed magnetic release includingmaking incoming & out going connectioncomplete all as specified and directed |
| 52 | S&F in replacementMCCB, 4 pole, 415 volt, 250 Amp,breaking capacity 36 KA, with fixed thermal and fixed magnetic release includingmaking incoming & out going connectioncomplete all as specified and directed |
| 53 | S&F in replacementMCCB, 4 pole, 415 volt, 200 Amp,breaking capacity 25 KA, with fixed thermal and fixed magnetic release includingmaking incoming & out going connectioncomplete all as specified and directed |
| 54 | S&F in replacementMCCB, 4 pole, 415 volt, 160 Amp,breaking capacity 25 KA, with fixed thermal and fixed magnetic release includingmaking incoming & out going connectioncomplete all as specified and directed |
| 55 | S&F in replacementMCCB, 4 pole, 415 volt, 125 Amp,breaking capacity 16 KA, with fixed thermal and fixed magnetic release includingmaking incoming & out going connectioncomplete all as specified and directed |
| 56 | S&F in replacementMCCB, 4 pole, 415 volt, 100 Amp,breaking capacity 16 KA, with fixed thermal and fixed magnetic release includingmaking incoming & out going connectioncomplete all as specified and directed |
| 57 | S&F in replacementMCCB, 4 pole, 415 volt, 63 Amp,breaking capacity 16 KA, with fixed thermal and fixed magnetic release includingmaking incoming & out going connectioncomplete all as specified and directed |
| 58 | S&F bus bar chamber of size 75cmx60cmx40cm,pedestal type,outdoor type, made out of 2.0mm thick mild steel sheet,vermin& dust proof duly painted and consisting with aluminium bus bar three phase & neutral,4 Nos, 400 Amps fixed on insulators with PCC 1:3:6 (using 20mm graded crushed stone agreegates) including danger platecomplete all as specified and directed |
| 59 | M&L for rendering 15 mm thick in cement mortar 1:4on brick work or concrete surfaces finished even and smooth without using extra cement including taking down existing cement plaster complete all as specified and directed |
| 60 | M&L for preparation of newly plastered or unplastered surfaces of wall and applying two coat of cement base paint over a coat of white wash complete all as specified and directed |
| 61 | S&F in replacement galvanised steel stay wire stranded of size 7/3.15mm complete all as specified and directed . |
| 62 | Supply only self adhesive PVC electrical insulation tape of size 1.80cm x 8mx 0.125 mm complete all as specified and directed. |
| 63 | M&L for preparation of old painted steel surfaces of LT panelafter removing existing old paint with the help of sand/emery paper and painting with one coat of synthetic enamel paint includingsurface dressing to the depth upto 25 cmaround 1 mtr of the panels complete all as specified and directed. |
| 64 | S&F in replacement danger notice plate of size 20x15cm made outof 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts complete all as specified and directed. |
| 65 | S&F in replacement LED post top lantern of 10 watt, IP 65,fitted on minimum 1 meter coloured metallic pipe including PCC work complete all as specified and directed. |
| 66 | S&F in replacement power contactor 150 Amp 3 pole 50 Hz complete all as specified and directed. |
| 67 | Supply, installation, commissioning and testing factory made LT panel board, CPRI approved, suitable for 3 phase, 4 wire, 415 Volts, AC supply, indoor cubical type,dust and vermin proof, powder coated, made out of 2.0 mm thick CRCA sheet with angle iron frame made out of MS angle 40 x 40 x 6 mm both side openable, double door type with proper locking arrangements duly finishedusing powder coated paint of approved colour over a coat of red oxide primer all over steel surfaces with 50 cm high angle iron legs welded on four corners of frame embedded in PCC 1:2:4 ( using 20 mm graded crushed stone aggregates) upto 25 cm foundation and proper glanding, lugs and nuts bolts etc for all cables and comprising of following accessories including disconnecting and taking down existing panel etc complete all as directed with sufficient working space with and including to accomodate the following accessories: -(a) Aluminium bus bar 800 Amps rating 3 phase 4 wire system. (b) Digital voltmeter 0-500 V - 01 Nos. (c) Digital ammeter 0-600 Amps with CTs – 01 Set. (d) LED type indicator 230 volts for RYB – 01 Set Incoming:- (a) MCCB 4 Pole 630 Amp 415 volts with thermal magnetic release Outgoings:- (a) MCCB 415 volts, 4 pole 320 Amps with breaking capacity 36 KA – 03 Nos. (b) MCCB 415 volts, 4 pole 100 amps with breaking capacity 16 KA – 01 Nos. (c) MCB SPN 40 Amp- 02 Nos |
| 68 | S&F in replacement LT spacerin LT overhead line of ACSR conductormade of high quality regid PVC, water proof ,weather proof & shock proof. The spacer shall also be suitable for use onboth horizental and vertically configuration of LT O/H line ACSR conductor 5 wire /4 wire system complete all as specified and directed.Note :- A Sum of Rs. 89515.00 will be deducted on account of credit for dismantling/demolished/taking down material. Please refer detail on srl page No 23 (Schedule of credit) of Tender Documents. |