Tender For Repair/Maintenance Of Dg Set With Amf Panel At Zone 5 And 1 (A, B, C) Zone 1, 3 (A And B), Zone 2 And Zone 4 Under Ge (S) Tezpur, tezpur-Assam

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Dg Set With Amf Panel At Zone 5 And 1 (A, B, C) Zone 1, 3 (A And B), Zone 2 And Zone 4 Under Ge (S) Tezpur. Submission Date for this Tender is 27-05-2023. Diesel Generators Tenders in tezpur Assam. Bidders can get complete Tender details and download the document.




Tender Notice

37468598
Corrigendum : Tender For Repair/Maintenance Of Dg Set With Amf Panel At Zone 5 And 1 (A, B, C) Zone 1, 3 (A And B), Zone 2 And Zone 4 Under Ge (S) Tezpur
Open Tender
Indian
Assam
tezpur
27-05-2023

Tender Details

Repair/Maintenance Of Dg Set With Amf Panel At Zone 5 And 1 (A, B, C) Zone 1, 3 (A And B), Zone 2 And Zone 4 Under Ge (S) Tezpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-May-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-05-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work: Repair/maintenance of DG Set with AMF Panel at Zone 5 & 1 (A,B,C) Zone 1, 3 (A & B), Zone 2 and Zone 4 under GE (S) Tezpur
Sl. No. Item Description
1Maint and servicing of DG set 320-400 KVA canopy typewith AMF Panel (if installed ), through authorize service agencyofOEM , including replacement of defective/workout parts with new spares such as filters, gaskets, V belts, Engine Oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vacuum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of POL tankand radiator etc,complete all as specified and directed. Make - Kirloskar/Cummins/greaves/Ashok Leyland / As per OEM Note:-1. spares required for above maint will be measured and paid separately under relevant items of Schedule.2. All breakdown calls should be attended.
2All as per Item No-1 Above but for DG set of capacity 180-250 KVA
3All as per Item No-1 Above but for DG set of capacity 100-160 KVA
4All as per Item No-1 Above but for DG set of capacity 40-82.5 KVA
5All as per Item No-1 Above but for DG set of capacity 25-35 KVA
6S & F in repair Fuel filter for 300-400 KVA DG set, complete all as specified and directed.Make : As per OEM
7S & F in repair Fuel filter for 125-250 KVA DG set, complete all as specified and directed. Make : As Per OEM
8S & F in repair Fuel filter for 25-100 KVADG set, complete all as specified and directed. Make : As Per OEM.
9S & F in repair Lub oil filter for 300-400 KVA DG set, complete all as specified and directed. Make : As Per OEM.
10S & F in repair Lub oil filter for 125-250 KVA DG set, complete all as specified and directed. Make : As Per OEM
11S & F in repair Lub oil filter for 25-100 KVA DG set, complete all as specified and directed. Make : As Per OEM
12S & F in repair Air cleaner filter ( inner and outer ) for 300-400 KVA DG set, complete all as specified and directed. Make : As Per OEM.
13S & F in repair Air cleaner filter (inner and outer ) for 200-250 KVA DG set, complete all as specified and directed. Make : As Per OEM
14S & F in repairAir cleaner filter (inner and outer ) for 25-100 KVA DG set, complete all as specified and directed.Make : As Per OEM
15S & F in repair Bypass filter for 300-400 KVA DG set, complete all as specified and directed.Make : As Per OEM.
16S & F in repair Bypass filter for 125-250 KVA DG set, complete all as specified and directed.Make :As Per OEM
17S & F in repair Bypass filter for 25-100 KVA DG set, complete all as specified and directed.Make : As Per OEM
18S & F in repairV belt for 300-400 KVA DG set, complete all as specified and directed. Make : As Per OEM
19S & F in repair V belt for 125-250 KVA DG set, complete all as specified and directed.Make : As Per OEM
20S & F in repair V belt for 25-100 KVA DG set, complete all as specified and directed.Make : As Per OEM
21S & F in repair Display control panel (LED Board) for 25 to 100 kva DG set, complete all as specified and directed.Make : As Per OEM.
22S & F in repair Display control panel (LED Board) for 125 to 250 kva DG set, complete all as specified and directed.Make : As Per OEM.
23S & F in repair Display control panel (LED Board) for 300 to 400 kva DG set, complete all as specified and directed.Make : As Per OEM.
24S & F in repair Fuel actuator with O Ring for 25 to 100kva DG set, complete all as specified and directed.Make : As Per OEM
25S & F in repair Fuel actuator with O Ring for 125 to 250 kva DG set, complete all as specified and directed.Make : As Per OEM
26S & F in repair Fuel actuator with O Ring for 300 to 400 kva DG set, complete all as specified and directed.Make : As Per OEM
27S & F in repair Key switchfor 25 to 400kva DG set, complete all as specified and directed. Make : As Per OEM
28S & F in repair coolant temperature sensor (coolent control safety) for 25 to 400kva DG set, complete all as specified and directed. Make : As Per OEM
29S & F in repairAMF controller assy for auto/manual operation for 25 to 100 kva DG set, complete all as specified and directed. Make : As Per OEM
30S & F in repairAMF controller assy for auto/manual operation for 125 to 250 kva DG set, complete all as specified and directed.Make : As Per OEM
31S & F in repairAMF controller assy for auto/manual operation for 300 to 400kva DG set, complete all as specified and directed. Make : As Per OEM
32S & F in repairControl assy main generator panel any type for 25 to 100 kva DG set, complete all as specified and directed. Make : As Per OEM
33S & F in repairControl assy main generator panel any type for 125 to 250 kva DG set, complete all as specified and directed. Make : As Per OEM
34S & F in repairControl assy main generator panel any type for 300 to 400 kva DG set, complete all as specified and directed. Make : As Per OEM
35S & F in repair Lube oil pressuresensor adaptor (oil control safety ) 25 to 400 kva DG set, complete all as specified and directed. Make : As Per OEM
36S & F in repair Stop solenoid switch 12 Volts, complete all as specified and directed.Make As Per OEM
37S & F in repair Stop solenoid switch 24 Volts, complete all as specified and directed.Make- As Per OEM
38Supply & Fill Coolantfor radiators complete all as specified and directed. Make- As Per OEM
39S & F in repair Turbo charger for 25-100 capacity DG set ,complete all as specified and directed.Make- As Per OEM
40S & F in repair Turbo charger for 125-250 capacity DG set complete all as specified and directed. Make- As Per OEM
41S & F in repair Turbo charger for 300-400 capacity DG set complete all as specified and directed. Make- As Per OEM
42Supply & Fill engine oil multi grade 15W40 all as specified and directed. (Make ELF Oil/ Castrol /HP or equivalent of OEM make)
43S & F in repair Automatic Voltage Regulator fit for 25-100 capacity DG set complete all as specified and directed. Make- As Per OEM
44S & F in repair Automatic Voltage Regulator fit for 125-250 capacity DG set complete all as specified and directed. Make- As Per OEM
45S & F in repair Automatic Voltage Regulator fit for 300-400 capacity DG set complete all as specified and directed. Make- As Per OEM
46Calibration of FIP and fuel injector from the authorized dealer including petty repairs to make the FIP and injectors functional for the following capacities ofDG set up to and including 100 KVA (Certificate to this effect that calibration and repair is carried out by authorized dealer will be submitted by the contractor),complete all as specified and directed.
47Calibration of FIP and fuel injector from the authorized dealer including petty repairs to make the FIP and injectors functional for the following capacities ofDG set 125-250 KVA (Certificate to this effect that calibration and repair is carried out by authorized dealer will be submitted by the contractor) all as specified and directed.
48Calibration of FIP and fuel injector from the authorized dealer including petty repairs to make the FIP and injectors functional for the following capacities ofDG set 300-400KVA (Certificate to this effect that calibration and repair is carried out by authorized dealer will be submitted by the contractor) all as specified and directed.
49Disconnecting the electric connection of Alternator of capacity 25-100 KVA DG set,taking the accumulator and cleaning the core assemblythrough air blower, heat varnishing with insulating material complete all as directed.
50Disconnecting the electric connection ofAlternator of capacity 125-250 KVA DG set,taking the accumulator and cleaning the core assemblythrough air blower, heat varnishing with insulating material, complete all as specified and directed.
51Disconnecting the electric connection ofAlternator of capacity 300-400 KVA DG set,taking the accumulator and cleaning the core assemblythrough air blower, heat varnishing with insulating material, complete all as specified and directed.
52S & F in repair Lub Oil cooler plate ,complete all as specified and directed. Make- As Per OEM
53S & F in repair Lub Oil pressure gauge pipe of required standard size ,complete all as specified and directed. Make- As Per OEM
54S & F in repair Oil spray nozzle assembly ,complete all as specified and directed.Make- As Per OEM
55S & F in repair Piston assembly of 25 - 400 KVA DG Set complete all as specified and directed. Make- As Per OEM
56S & F in repair Main Bearing of various sizes for DG set of different capacity complete all as specified and directed.Make- As Per OEM
57S & F in repair Water temp switchcomplete all as specified and directed. Make- As Per OEM
58S & F in repair Lub Oil pump high discharge of required standard size complete all as specified and directed. Make- As Per OEM
59S & F in repair of field coil assembly for 25-400 KVA DG set, complete all as specified and directed. Make- As Per OEM
60S & F in repair of Eye bolt for 25-400 KVA DG set, complete all as specified and directed.Make- As Per OEM.
61S & F in repair of fan key for 25-400 KVA DG set, complete all as specified and directed. Make- As Per OEM
62S & F in repair of fan assembly for 25-400 KVA DG set, complete all as specified and directed. Make- As Per OEM
63S & F in repair of fan for 25-400 KVA DG set, complete all as specified and directed. Make- As Per OEM
64S & F in repair of Circle for 25-400 KVA DG set, complete all as specified and directed. Make- As Per OEM
65S & F in repair of DE Bearing for 25-400 KVA DG set, complete all as specified and directed. Make- As Per OEM
66S & F in repair of Brush holder spindlefor 25-400 KVA DG set, complete all as specified and directed. Make- As Per OEM
67S & F in repair of NDE bearing cap for125/100/75/62.5kva DG set, complete all as specified and directed. Make- As Per OEM
68S & F in repair of Slip ring assembly for 25 -400 KVA DG set ,complete all as specified and directed.Make- As Per OEM.
69S & F in repair of Excitation (CX) unit for 25-100 KVA DG set, complete all as specified and directed.Make- As Per OEM
70S & F in repair of Excitation (CX) unit for 125 - 250 kva DG set, complete all as specified and directed. Make- As Per OEM
71S & F in repair of Excitation (CX) unit for 300-400 kva DG set, complete all as specified and directed. Make- As Per OEM.
72S&F battery terminal cable , copper conductor multi strand, unsheathed, single core25sqmm, 1.5 mtr long each for negative and positive terminal fixed/solder with battery terminal clamp and copper lugs each side of cable suitable for 180 AH Battery (Set of 2 nos.) complete all as specified and directed.
73Taking down unserviceable battery and supply and fixing 12 volt, 180 AH battery complete all as specified and directed.
74Taking down unserviceable battery and supply and fixing 12 volt, 100 AH battery complete all as specified and directed.
75M/L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etcfor 25-160 KVA capacities of DG Set, complete all as specified and directed.
76M/L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etcfor 200-400 KVA capacities of DG Set, complete all as specified and directed.
77Taking down the unserviceable radiator for 25-160 KVA from engine, transportation to the workshop dismantling the radiator, repair the tank /storage portion incl necessary welding & making leak proof of the tank, cleaning the complete radiator with chemical agent and pumping set incl replacement of defective copper core and assembling the radiator including replacement of all old rusted MS nuts, bolts washers & gasket sets including refixing in to the existing position & onthe engine and testing ,complete all as specified and directed.
78Taking down the unserviceable radiator for 200-400 KVA from engine, transportation to the workshop dismantling the radiator, repair the tank /storage portion incl necessary welding & making leak proof of the tank, cleaning the complete radiator with chemical agent and pumping set incl replacement of defective copper core and assembling the radiator including replacement of all old rusted MS nuts, bolts washers & gasket sets including refixing in to the existing position & onthe engine and testing ,complete all as specified and directed.
79S & F in repair self starter 78 volt dc complete all as specified, complete all as specified and directed.Make- As Per OEM
80S & F in repair self starter 12 volt dc ,complete all as specified and directed.Make- As Per OEM
81Repair, transporting, taking down and servicing of self starter 12/24 volt dc at authorized service centre including refixing the same and testing ,complete all as specified and directed.
82Maintenance and servicing the AMF panel and replace the unserviceable items and testing and replace unserviceable wiring connection in panel for automatic operation through relay, contactor, timer, sensor etc,complete all as specified and directed.
83S & F in repair of Digital multi function meter suitable for AMF panel, complete all as specified and directed.Make- As Per OEM
84S & F in repair of indicator lamp (R,Y & B) suitable for AMF panel, complete all as specified and directed.
85S & F in repair of three pole power contractor type MNX-250 with Aux contracts 2 Nos 2 NC , suitable for AMF panel, complete all as specified and directed.
86S & F in repair of three pole power contractor type MNX-300 with Aux contracts 2 Nos 2 NC , suitable for AMF panel ,complete all as specified and directed.
87S & F in repair of three pole power contractor type MNX-550 with Aux contracts 2 Nos 2 NC , suitable for AMF panel, complete all as specified and directed.
88S & F in repair of AC Control contactor - M00AC - 15 4A at 415 Volt suitable for AMF panel, complete all as specified and directed.
89S & F in repair of DC control contactor M00AC 15 4A at 415 volt suitable for AMF panel, complete all as specified and directed.
90S&F Manual change over switch fitted in sheet steel enclosure400 Amp, 4P 415V, 50 Hz withafter disconnecting all electrical connections including dismantling old unserviceable and making necessary electrical connections complete all as specified and as directed. Make : Havells cat code IHCNFO0400 or equivalent make of Legrand/Schneider/L&T/ABB/Indo Asian
91All as per item No. 90.00 here-in-before but of capacity 250 amps ,complete all as specified and directed.(Make : Havells cat code IHCNFO0250 or equivalent make of Legrand/Schneider/L&T/ABB/Indo Asian
92All as per item No. 45.00 here-in-before but of capacity 100 amps,complete all as specified and directed.(Make : Havells cat code IHCNFO0100 or equivalent make of Legrand/Schneider/L&T/ABB/Indo Asian
93S&F Digital SMPS battery charger 12 volts, 10 amps capacity including Amp meter, Volt Meter, Selector switch, Indicator lamp, fuse unit, rectifier, cord etcand testing complete all specified and directed.
94S&F Digital SMPS battery charger 24 volts 20 Amp capacity including Amp meter, Volt Meter, Selector switch, Indicator lamp, fuse unit, rectifier, cord etcand testing complete all specified and directed. Note 1:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount. Note 2-Contractor"s supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embosed with contractor"s firm name while carriying out any activities in defence area for better check of security purpose.Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs)