Housing Urban and Rular Development Government Departments Closing in 0 days TDR #37457868

Tender For Construction Of New Opd Building At Community Health Centre, Polasara Ama Hospital Under 5T Transformation In The District Of Ganjam, Odisha.

Issued by Government Departments · polasara, Odisha
Tender Value
4.34 Crore
Estimated cost
Bid Submission
08 May 2023
0 days left
EMD
4.34 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
polasara → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of New Opd Building At Community Health Centre, Polasara Ama Hospital Under 5T Transformation In The District Of Ganjam, Odisha. New Opd Building Under Ama Hospital 5T

BOQ

Name of Work: Construction of new OPD Building at Community Health Centre, Polasara AMA Hospital under 5T Transformation in the District of Ganjam, Odisha.
Sl. No. Item Description
1Civil WorksDismantling brick or stone masonary in lime or cement mortar below 10\" height including stacking the useful materials for reuse and removing the debris with 50 m. lead including all labour, labour cess, T&P etc. complete as directed by the Engineer-in-charge.
2Dismantling and removing RCC columns, beams, slab, staircase, landing, lintels including stacking the materials for reuse and removing the debris within 50 m. lead including all labour, labour cess, T&P etc. complete as directed by the Engineer-in-charge.
3Earth work in excavation in foundation in hard or gravelly soil within 50 mtr. initial lead and 1.5 mtr. initial lift including rough dressing and breaking clods to maximum 5 cm to 7 cm and laying in layers not exceeding 0.3 mtr. depth including cost of all labour, labour cess and T&P for the work etc. complete and as directed by the Engineer-in-Charge.
4Earth work excavation in foundation in stoney earth and gravels mixed with stone and boulder not exceeding 0.014 cum. in volume within 50 mtr. initial lead and 1.5 mtr. initial lift including rough dressing and breaking clods to maximum 5 cm to 7 cm and laying in layers not exceeding 0.3 mtr. depth including cost of all labour, labour cess and T&P for the work etc. complete and as directed by the Engineer-in-Charge.
5Supplying, filling in foundation and plinth with sand in 22.5 cm (9\") thick layers including watering and ramming with cost, conveyance, royalties, labour and labour cess with T&P required for the work etc complete as per the direction of the Engineer-in-charge.
6Cement concrete of proportion (1:3:6) in foundation and floors using 4 cm (1.5\") size clean hard hand broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm (6\") thick to required level ramming, watering, curing etc. complete including cost and conveyance of all materials with royalties, labour, labour cess and T&P required for the work etc. complete including dewatering if required.
7R.C.C. work in Column Base of grade M25 having a minimum compressive strength work test of 250 Kg./cm. in 15 cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 20 mm size downgraded (20 mm not to exceed 25%) hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting, lowering, laying and compacting concrete watering and curing for 4 weeks centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials, labour and labour cess with T&P required for the work etc. complete in all respect but excluding the cost and conveyance ofM.S rods or Tor steel and bindingwire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding etc of the M.S. Rods or Tor Steel andbinding wire tying the grills and placingin proper position.
8R.C.C. work in Plinth Beam of grade M25 having a minimum compressive strength work test of 250 Kg./cm. in 15 cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 20 mm size downgraded (20 mm not to exceed 25%) hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting, lowering, laying and compacting concrete watering and curing for 4 weeks centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials, labour and labour cess with T&P required for the work etc. complete in all respect but excluding the cost and conveyance ofM.S rods or Tor steel and bindingwire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding etc of the M.S. Rods or Tor Steel andbinding wire tying the grills and placingin proper position.
9R.C.C. work in Column & Beam of grade M25 having a minimum compressive strength work test of 250 Kg./cm. in 15 cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 20 mm size downgraded (20 mm not to exceed 25%) hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting, lowering, laying and compacting concrete watering and curing for 4 weeks centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials, labour and labour cess with T&P required for the work etc. complete in all respect but excluding the cost and conveyance ofM.S rods or Tor steel and bindingwire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding etc of the M.S. Rods or Tor Steel andbinding wire tying the grills and placingin proper position. - In Ground Floor
10R.C.C. work in Column & Beam of grade M25 having a minimum compressive strength work test of 250 Kg./cm. in 15 cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 20 mm size downgraded (20 mm not to exceed 25%) hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting, lowering, laying and compacting concrete watering and curing for 4 weeks centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials, labour and labour cess with T&P required for the work etc. complete in all respect but excluding the cost and conveyance ofM.S rods or Tor steel and bindingwire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding etc of the M.S. Rods or Tor Steel andbinding wire tying the grills and placingin proper position.- In First floor
11R.C.C. work in Column & Beam of grade M25 having a minimum compressive strength work test of 250 Kg./cm. in 15 cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 20 mm size downgraded (20 mm not to exceed 25%) hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting, lowering, laying and compacting concrete watering and curing for 4 weeks centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials, labour and labour cess with T&P required for the work etc. complete in all respect but excluding the cost and conveyance ofM.S rods or Tor steel and bindingwire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding etc of the M.S. Rods or Tor Steel andbinding wire tying the grills and placingin proper position.- In Second floor
12R.C.C. work in Lintel of grade M25 having a minimum compressive strength work test of 250 Kg./cm. in 15 cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 20 mm size downgraded (20 mm not to exceed 25%) hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting, lowering, laying and compacting concrete watering and curing for 4 weeks centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials, labour and labour cess with T&P required for the work etc. complete in all respect but excluding the cost and conveyance ofM.S rods or Tor steel and bindingwire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding etc of the M.S. Rods or Tor Steel andbinding wire tying the grills and placingin proper position - In Ground Floor.
13R.C.C. work in Lintel of grade M25 having a minimum compressive strength work test of 250 Kg./cm. in 15 cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 20 mm size downgraded (20 mm not to exceed 25%) hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting, lowering, laying and compacting concrete watering and curing for 4 weeks centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials, labour and labour cess with T&P required for the work etc. complete in all respect but excluding the cost and conveyance ofM.S rods or Tor steel and bindingwire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding etc of the M.S. Rods or Tor Steel andbinding wire tying the grills and placingin proper position.- In First floor
14R.C.C. work in Lintel of grade M25 having a minimum compressive strength work test of 250 Kg./cm. in 15 cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 20 mm size downgraded (20 mm not to exceed 25%) hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting, lowering, laying and compacting concrete watering and curing for 4 weeks centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials, labour and labour cess with T&P required for the work etc. complete in all respect but excluding the cost and conveyance ofM.S rods or Tor steel and bindingwire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding etc of the M.S. Rods or Tor Steel andbinding wire tying the grills and placingin proper position.- In Second floor
15R.C.C. work in Stair Case of grade M25 having a minimum compressive strength work test of 250 Kg./cm. in 15 cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 20 mm size downgraded (20 mm not to exceed 25%) hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting, lowering, laying and compacting concrete watering and curing for 4 weeks centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials, labour and labour cess with T&P required for the work etc. complete in all respect but excluding the cost and conveyance ofM.S rods or Tor steel and bindingwire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding etc of the M.S. Rods or Tor Steel andbinding wire tying the grills and placingin proper position - In Ground Floor
16R.C.C. work in Stair Case of grade M25 having a minimum compressive strength work test of 250 Kg./cm. in 15 cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 20 mm size downgraded (20 mm not to exceed 25%) hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting, lowering, laying and compacting concrete watering and curing for 4 weeks centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials, labour and labour cess with T&P required for the work etc. complete in all respect but excluding the cost and conveyance ofM.S rods or Tor steel and bindingwire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding etc of the M.S. Rods or Tor Steel andbinding wire tying the grills and placingin proper position - In First Floor.
17R.C.C. work in Roof slab of grade M25 having a minimum compressive strength work test of 250 Kg./cm. in 15 cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 20 mm size downgraded (20 mm not to exceed 25%) hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting, lowering, laying and compacting concrete watering and curing for 4 weeks centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials, labour and labour cess with T&P required for the work etc. complete in all respect but excluding the cost and conveyance ofM.S rods or Tor steel and bindingwire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding etc of the M.S. Rods or Tor Steel andbinding wire tying the grills and placingin proper position - In Ground Floor
18R.C.C. work in Roof slab of grade M25 having a minimum compressive strength work test of 250 Kg./cm. in 15 cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 20 mm size downgraded (20 mm not to exceed 25%) hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting, lowering, laying and compacting concrete watering and curing for 4 weeks centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials, labour and labour cess with T&P required for the work etc. complete in all respect but excluding the cost and conveyance ofM.S rods or Tor steel and bindingwire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding etc of the M.S. Rods or Tor Steel andbinding wire tying the grills and placingin proper position.- In First floor
19R.C.C. work in Roof slab of grade M25 having a minimum compressive strength work test of 250 Kg./cm. in 15 cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 20 mm size downgraded (20 mm not to exceed 25%) hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting, lowering, laying and compacting concrete watering and curing for 4 weeks centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials, labour and labour cess with T&P required for the work etc. complete in all respect but excluding the cost and conveyance ofM.S rods or Tor steel and bindingwire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding etc of the M.S. Rods or Tor Steel andbinding wire tying the grills and placingin proper position.- In Second floor
20R.C.C. work in Chajja of grade M25 having a minimum compressive strength work test of 250 Kg./cm. in 15 cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 20 mm size downgraded (20 mm not to exceed 25%) hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting, lowering, laying and compacting concrete watering and curing for 4 weeks centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials, labour and labour cess with T&P required for the work etc. complete in all respect but excluding the cost and conveyance ofM.S rods or Tor steel and bindingwire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding etc of the M.S. Rods or Tor Steel andbinding wire tying the grills and placingin proper position In Ground Floor
21R.C.C. work in Chajja of grade M25 having a minimum compressive strength work test of 250 Kg./cm. in 15 cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 20 mm size downgraded (20 mm not to exceed 25%) hard crusher broken granite stone chips of approved quality and from approved quarry including hoisting, lowering, laying and compacting concrete watering and curing for 4 weeks centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials, labour and labour cess with T&P required for the work etc. complete in all respect but excluding the cost and conveyance ofM.S rods or Tor steel and bindingwire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding etc of the M.S. Rods or Tor Steel andbinding wire tying the grills and placingin proper position.- In First floor
22Straightening bent up or coiled rods (HYSD) cutting, bending, cranking, hooking, welding or jointing (if required) the M.S. Rods or Tor steel and binding wires and binding, tying the grills, hoisting, lowering and placing in proper position as required for RCC works and for providing cost, conveyance of M.S. rod or Tor steel and binding wires of 18 to 20 gauge and labour, labour cess with T & P required for the work etc complete in all floors (Weight of binding wires and lapping & wastage of rod will not be considered for payment and payment will be made on weight of actual length of M.S. rods or Tor steel only.)- In Ground floor
23Straightening bent up or coiled rods (HYSD) cutting, bending, cranking, hooking, welding or jointing (if required) the M.S. Rods or Tor steel and binding wires and binding, tying the grills, hoisting, lowering and placing in proper position as required for RCC works and for providing cost, conveyance of M.S. rod or Tor steel and binding wires of 18 to 20 gauge and labour, labour cess with T & P required for the work etc complete in all floors (Weight of binding wires and lapping & wastage of rod will not be considered for payment and payment will be made on weight of actual length of M.S. rods or Tor steel only.)- In First floor
24Straightening bent up or coiled rods (HYSD) cutting, bending, cranking, hooking, welding or jointing (if required) the M.S. Rods or Tor steel and binding wires and binding, tying the grills, hoisting, lowering and placing in proper position as required for RCC works and for providing cost, conveyance of M.S. rod or Tor steel and binding wires of 18 to 20 gauge and labour, labour cess with T & P required for the work etc complete in all floors (Weight of binding wires and lapping & wastage of rod will not be considered for payment and payment will be made on weight of actual length of M.S. rods or Tor steel only.)- In Second floor
25Fly ash brick masonry in cement mortar (1:6) after immersing bricks for six hours in water before use in Foundation and plinth using fly ash bricks of 9\" size having a crushing strength of not less than 75 Kg. per sq. cm including splays, cutting, circular mouldings, chamfering, corbelling and similar such type of works with all necessary projections, watering and curing etc. complete including cost and conveyance of all materials, labour and labour cesswith T&P required for the work with all royalties etc. complete in all respect. 4097.33
26Fly ash brick masonry in cement mortar (1:6) after immersing bricks for six hours in water before use in superstructure using fly ash bricks of 9\" size having a crushing strength of not less than 75 Kg. per sq. cm including splays, cutting, circular mouldings, chamfering, corbelling and similar such type of works with all necessary projections, watering and curing etc. complete including cost and conveyance of all materials, labour and labour cesswith T&P required for the work with all royalties etc. complete in all respect. -In Ground floor
27Fly ash brick masonry in cement mortar (1:6) after immersing bricks for six hours in water before use in superstructure using fly ash bricks of 9\" size having a crushing strength of not less than 75 Kg. per sq. cm including splays, cutting, circular mouldings, chamfering, corbelling and similar such type of works with all necessary projections, watering and curing etc. complete including cost and conveyance of all materials, labour and labour cesswith T&P required for the work with all royalties etc. complete in all respect. - In First floor
28Fly ash brick masonry in cement mortar (1:6) after immersing bricks for six hours in water before use in superstructure using fly ash bricks of 9\" size having a crushing strength of not less than 75 Kg. per sq. cm including splays, cutting, circular mouldings, chamfering, corbelling and similar such type of works with all necessary projections, watering and curing etc. complete including cost and conveyance of all materials, labour and labour cesswith T&P required for the work with all royalties etc. complete in all respect. - In Second floor
2912 mm thick cement plaster (1:6) finished smooth to outside brick walls after raking out the joint including watering and curing with cost and conveyance of all materials and labour, labour cess with T&P required for the work with all royalties etc. complete in all respect as per direction of the Engineer-in-charge - In Ground Floor
3012 mm thick cement plaster (1:6) finished smooth to outside brick walls after raking out the joint including watering and curing with cost and conveyance of all materials and labour, labour cess with T&P required for the work with all royalties etc. complete in all respect as per direction of the Engineer-in-charge.- In First floor
3112 mm thick cement plaster (1:6) finished smooth to outside brick walls after raking out the joint including watering and curing with cost and conveyance of all materials and labour, labour cess with T&P required for the work with all royalties etc. complete in all respect as per direction of the Engineer-in-charge.- In Second floor
3216 mm thick cement plaster of proportion (1:6) finished smooth to inside brick work after racking out joints including watering and curing, cost, conveyance, royalities of all materials with all labour, labour cess and T&P required for the work etc complete in all respect as per direction of the Engineer-in-charge - In Ground Floor
3316 mm thick cement plaster of proportion (1:6) finished smooth to inside brick work after racking out joints including watering and curing, cost, conveyance, royalities of all materials with all labour, labour cess and T&P required for the work etc complete in all respect as per direction of the Engineer-in-charge.- In First floor
3416 mm thick cement plaster of proportion (1:6) finished smooth to inside brick work after racking out joints including watering and curing, cost, conveyance, royalities of all materials with all labour, labour cess and T&P required for the work etc complete in all respect as per direction of the Engineer-in-charge.- In Second floor
356 mm thick cement plaster (1:4) to RCC surfaces finished smooth including close deep chipping and slurry treatment including watering and curing with cost and conveyance of all materials and labour, labour cess with T&P required for the work with all royalties etc. complete in all respect as per direction of the Engineer-in-charge - In Ground Floor.
366 mm thick cement plaster (1:4) to RCC surfaces finished smooth including close deep chipping and slurry treatment including watering and curing with cost and conveyance of all materials and labour, labour cess with T&P required for the work with all royalties etc. complete in all respect as per direction of the Engineer-in-charge - In First Floor.
376 mm thick cement plaster (1:4) to RCC surfaces finished smooth including close deep chipping and slurry treatment including watering and curing with cost and conveyance of all materials and labour, labour cess with T&P required for the work with all royalties etc. complete in all respect as per direction of the Engineer-in-charge - In Second Floor.
38Supplying, fitting and fixing of Vitrified tile in floors of size 600mm x 600mm of plain (Ivory) in approved make conforming to IS 13756 laid on 20mm thick cement mortar (1:4) (1cement:4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour, labour cess and T&P etc. required for the work all complete as per direction of the Engineer-in-charge - In Ground Floor
39Supplying, fitting and fixing of Vitrified tile in floors of size 600mm x 600mm of plain (Ivory) in approved make conforming to IS 13756 laid on 20mm thick cement mortar (1:4) (1cement:4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour, labour cess and T&P etc. required for the work all complete as per direction of the Engineer-in-charge.- In First floor
40Supplying, fitting and fixing of Vitrified tile in dadoes of size 600mm x 600mm of plain (Ivory) in approved make conforming to IS 13756 laid on 20mm thick cement mortar (1:4) (1cement:4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour, labour cess and T&P etc. required for the work all complete as per direction of the Engineer-in-charge.- In First floor
41Providing & fixing of Granite Tiles above 0.10 sqm. & upto 0.40sqm. (10mm thick)in floors, treads or steps and landing on 25 mm thick bed of cement mortar (1:1) jointed with neat cement slurry mixed with colouring pigments to match the sheds of the tiles including cost of Granite tiles, all materials, labour, labour cess, royality, conveyance, T&P etc. complete as directed by the Engineer-in-charge - In Ground Floor
42Providing & fixing of Granite Tiles above 0.10 sqm. & upto 0.40sqm. (10mm thick)in floors, treads or steps and landing on 25 mm thick bed of cement mortar (1:1) jointed with neat cement slurry mixed with colouring pigments to match the sheds of the tiles including cost of Granite tiles, all materials, labour, labour cess, royality, conveyance, T&P etc. complete as directed by the Engineer-in-charge - In First Floor
43Providing & fixing of Ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size 30cm x 20cm / 20cm x 20cm special plain / printed series in dados, skirting and risers of steps on 12 mm thick cement mortar (1:3) jointed with neat cement slurry mixed with colouring pigments to match the sheds of the tiles including cost of ceramic wall tiles, all materials, labour, labour cess, royality, conveyance, T&P etc. complete as directed by the Engineer-in-charge - In Ground Floor.
44Providing & fixing of Ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size 30cm x 20cm / 20cm x 20cm special plain / printed series in dados, skirting and risers of steps on 12 mm thick cement mortar (1:3) jointed with neat cement slurry mixed with colouring pigments to match the sheds of the tiles including cost of ceramic wall tiles, all materials, labour, labour cess, royality, conveyance, T&P etc. complete as directed by the Engineer-in-charge - In First Floor.
45Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scafolding staging charges with cost of all materials, labour, labour cess, T&P etc. complete as per direction of Engineer-in-Charge.- In Ground floor
46Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scafolding staging charges with cost of all materials, labour, labour cess, T&P etc. complete as per direction of Engineer-in-Charge.- In First floor
47Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scafolding staging charges with cost of all materials, labour, labour cess, T&P etc. complete as per direction of Engineer-in-Charge.- In Second floor
48Priming wall surface with water based cement primer with approved water base cement primer on new work to receive painting after cleaning surface including cost of all materials, labour, labour cess, T&P required for the work etc complete as per direction of the Engineer-In-Charge.- In Ground floor
49Priming wall surface with water based cement primer with approved water base cement primer on new work to receive painting after cleaning surface including cost of all materials, labour, labour cess, T&P required for the work etc complete as per direction of the Engineer-In-Charge.- In First floor
50Priming wall surface with water based cement primer with approved water base cement primer on new work to receive painting after cleaning surface including cost of all materials, labour, labour cess, T&P required for the work etc complete as per direction of the Engineer-In-Charge.- In Second floor
51Wall painting two coats to wall surface with any approved Plastic Emulsion paint of approved shade on new work to give an even shade after cleaning surface including cost of all materials, labour, labour cess, T&P required for the work etc complete as per direction of the Engineer-In-Charge.- In Ground floor
52Wall painting two coats to wall surface with any approved Plastic Emulsion paint of approved shade on new work to give an even shade after cleaning surface including cost of all materials, labour, labour cess, T&P required for the work etc complete as per direction of the Engineer-In-Charge.-In First floor
53Wall painting two coats to wall surface with any approved Plastic Emulsion paint of approved shade on new work to give an even shade after cleaning surface including cost of all materials, labour, labour cess, T&P required for the work etc complete as per direction of the Engineer-In-Charge.-In Second floor
54Wall Painting two coats with any approved weather coat paint of approved shade on new work to give an even shade after cleaning surface including cost of all materials, labour, labour cess, T&P required for the work etc complete as per direction of the Engineer-In-Charge.- In Ground floor
55Wall Painting two coats with any approved weather coat paint of approved shadeon new work to give an even shade after cleaning surface including cost of all materials, labour, labour cess, T&P required for the work etc complete as per direction of the Engineer-In-Charge.- In First floor
56Wall Painting two coats with any approved weather coat paint of approved shadeon new work to give an even shade after cleaning surface including cost of all materials, labour, labour cess, T&P required for the work etc complete as per direction of the Engineer-In-Charge.- In Second floor
57Supplying and fitting fixing of Un-plasticised Poly vinyl chloride (UPVC) (FENESTA / NCL VEKA LTD) Three Track – Three Panel sliding window – 60 series duly manufactured using UPVC reinforced profiles of 108 mm X 45mm X 2.5mm for outer frames and window sash of 39mm X 58mm X 2.5mm capable of mounting single glazing system, structurally reinforced with hot dip galvanized up to 50 microns of minimum thickness of 1.5 mm prefabricated and welded through fusion welding the window, frame shall be fitted with 6 mm thick clear toughened glass of SAINT – GOBAIN make duly fixed with EPDM weathering seal resistant and the system is to be installed using Reinforced Large Coupler at the site using anchor fasteners , silicon rubber sealant, easy glazing/ deglazing at site etc. including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTM D 638-14, EN-477-95 and other applicable codes and standards.
58Supplying of M.S. Window grill / M.S. Fixed Grill / M.S. grill gate made out of M.S. angle, M.S. flat & M.S. square etc including cutting, welding, all labour, labour cess and T&P etc complete as per direction of Engineer-in-charge
59Labour charges for fitting and fixing of M.S. Door, Window, Fixed Grill & Gate, Rolling shutter etc. in proper position including making holes in walls, RCC structures and wood work etc. and making good to the damages to walls or RCC structure including mending or cutting to sizes or grooves in walls and fixing with RCC (1:2:4) with HB granite chips of 12mm size with cost and conveyance of all materials, royalties, labour, labour cess and T&P required for the work etc. complete as per direction of the Engineer-in-charge.
60Painting two coats with any approved paint over a coat of priming to new iron work including cost of the primer and paint sand papering polishing the surface with cost conveyance of all materials, labour and labour cess with T&P required for the work etc complete in all respect as per direction of the Engineer-in-charge.
61Supplying, fitting, and fixing of Stainless steel of 304 grade in hand railing using 50 mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in staircase as per approved design and specification, buffing, polishing etc. with cost, conveyance of all materials, labour, labour cess T&P etc. required for the complete in all respect as per direction of the Engineer-in-charge.
622.5 cm thick grading concrete (1:2:2:) on roof slabwith 6 mm size hard crusher broken granite chips including all cost, conveyance and royalties of materials with labour, labour cess and T&P required for the work etc. complete as per direction of Engineer-in-charge in First Floor
63Grid Ceilling :- (DUNE RH 99)Providing & Fixing of Mineral Fibre Board of microperforated, finely granulated surface texture , beveled tegular edge with 6mm Black Revealedexposed grid Suspended False Ceiling System, with tiles of Humidity Resistance (RH) of 99%, NRC Upto 0.5, awvalue 0.6, CAC- 34dB ,Light Reflectance >85%, thermal Conductivity k = 0.052- 0.057 w/m K, Colour White, Fire Performance Class- 0/ Class -1 (BS476 Part 6&7) in module size of 600 X 600 X 16 mm with Bio Block coating on the face of the tile,suitable for Green Building application, with Recycled content of 63%, fixed to G.I.grids of system with 15mm white flanges incorporating a 6mm central reveal in white/black colour and with a web height of 38mm, having stiches both perpedicular and horizontal to make it stronger, and a load carrying capacity of minimum 15.68 Kgs/Sqm. The Main Runners & Cross Tees to have mitred ends & “birdsmouth” notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 120 grams per SQM & passed through 500 hrs of Salt test. The main G.I. runner spaced at 1200mm centre to centre securely fixed to the structural soffit using G.I.suspension systemat 1200mm maximum centr to centre & not more than 150mm from spliced joints.The First/Lastsuspension system at the end of each main runner should not be greater than 600mm from the adjacent wall. 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module.Cut cross tees longer than 600mm require independent support.600 x 600mm modules to be formed by fitting 600mm long cross tees centrally between the 1200 mm cross tees. Perimeter trim to be shadow wall angle (dimensions: 19x7x7x14mm), secured to walls at maximum 450 mm C/C, complete in all respect with all labour, material etc. as directed by the Architect/Engineer-in-Charge. The rate includes all complete with materials, labour, T&P, taxes etc. (Fixtures should be independently supported from the soffit).
64Supply, fitting, fixing & installation of Bio Guard Mineral Fiber 600x600 16mm beveled edge with Silhouette grid of Armstong make especially for hospital OTS & Labour Rooms. The cost includes boards, running tracks, channels, labour T&P Etc
65Supply, fitting, fixing & installation of METALWORKS BAFFLE BLADE 100X50MM - WOOD - RED OAK/ CHERRY With accessories Armstong make. The cost includes boards, running tracks, channels, labour T&P Etc
66Providing & Fixing of WPC Door Frame size 5\" x 2.5\" having density 725kg/m3, make up of virgin polymer, wheat and rice husk fiber and Calcium silicate. 100% water proof, termite proof and fire retardant made of Alstone Chaukhat. The door will be provided with all necessary fitting & fixture of approved hardware and all materials complete as per direction of the Engineer-In-Chareg.
67Providing, fitting and fixing ofapproved make 35mm thick (laminate finished thickness of the door) factory made flush doors of the followings size finished with 1mm thk. laminate of approved colour & shade to both side fixed to the teak wood bidding.The glazing portion of the door will be as per drawing & design, made out of 8mm thick toughtned glass with itching as per drawing/design to be fixed with 50x18mm/ 48x24mm teak wood beading finished with melamine polish. The glass joiniting shall be tightened with silicon or with approved jointing material for proper rigidity. The door will be provided with all necessary fittings & fixtures, i.e. SS hinges, Lock etc. all of approved make complete in all respect with materials, labour, T&P, taxes etc. as per the design/drawings or Architect/Engineer-in-Charge.
68Providing, fitting & fixing of VINYL Antistatic floor panelling of wonderfloor makewith sheet thickness of 2mm especially made for hospitals as directed by Engineer In Charge/ Architect. The cost includes, material, labour & fixing etc with all accessories, T&P etc complete.
69Providing, fitting & fixing of VINYL Wallspro panelling of wonderfloor makewith sheet thickness of 1mm especially made for hospitals as directed by Engineer In Charge/ Architect. The cost includes, material, labour & fixing etc with all accessories, T&P etc complete.
70Providing, fitting & fixing of OT Antimicrobial PVC Sheet 2.5mm thick panelling of altro/jemiclad/bioclad/amclad/gohealth branded make especially made for hospitals as directed by Engineer In Charge/ Architect. The cost includes, material, labour & fixing etc with all accessories, T&P etc complete.
71ELECTRICAL WORKSINTERNAL WIRING.OLD BUILDINGRecessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq) (Make of modular box,cover,switch & socket-Legrand Myrios/schneider opale/Eq) With 10Years Warenty - Group-C
72Recessed wiring to secondary light pointlooped from primary light point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduitwith 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer-in-charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq)Average Length: 3mtr
73Recessed wiring to ceiling fan point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduit with 6Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq) Group B
74Recessed wiring to Twin control light pointwith 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6Amp, 250 V clip in type 2way switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer-in-charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq)Group C
75Recessed wiringfor 5 / 6 amp socket outletwith6Amp, 250 V clip in type modular switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on same switch board as per direction of Engineer-in-charge.
76Recessed wiringfor 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable size ,with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer-in-charge.(Make of wire Finolex /Polycab/ Anchor / Havels/Eq)Group C
77Recessed wiringfor2 x 6 amp socket outlet controlled by 2 nos6Amp, 250 V clip in type switch ISI markedmounted on single G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on separate board as per direction of Engineer-in-charge.
78Recessed wiringfor 6 pin 16 amp socket outletwith 16Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection as per direction of Engineer-in-charge. 25Nos for Stage Light,3Nos For Aquaguard.
79Recessed wiringfor A.C/ Power socket outletwithindustrial type socket outlet,plug top and metal chained cover in sheet steel enclosure,20A/32A SP MCBincluding all accesories and connection as per direction of Engineer-in-charge.
80Recessed wiring to exhaust fan/Wall Fan point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduit with 6Amp 250V Modular Switch, Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq)Group C
81Call bell point
82SUBMAINRecessed wiring to submain in 4 x 16 sq.mmFRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 50 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 10 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq)
83Recessed wiring to submain in 4 x 10 sq.mmFRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 40 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 6 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired.(Make of wire Finolex /Polycab/ Anchor / Havels/Eq)
84Recessed wiring to submain in 2 x 6 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 4 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq)
85Recessed wiring to submain in 2 x 4 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq)
86Recessed wiring to submain in 2 x 2.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq)
87Recessed wiring to submain in 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq) (For Switch Board Looping)
88Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required wih necessary MCB , RCCB / ISOLATORS as required.Note for MCB- There should be colour indication for tripping On ,Off & Trip/There should be mid tripposition for toggles for electrical fault conditions.(With 5Years Warenty)Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted6 way TPN Distribution Boards For PDB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-63AFPMCB (10KA)Outgoings-10/20A SP MCB 10KA-18Nos.(Make-L&T/ Schneider/Legrand/Eq)
89Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted6 way TPN Distribution Boards For LDB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-40AFPMCB (10KA)Outgoings-10A SP MCB 10KA-18Nos.(Make-L&T/ Schneider/Legrand/Eq)
90CABLESupply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of3.5core 300 sq.mm direct in groundincluding excavation , sand cushining protective covering and refilling the trench etc. as required.(Make-polycab/RR Kable/Rhino cable/Eq)
91Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of3.5core 185 sq.mm direct in groundincluding excavation , sand cushining protective covering and refilling the trench etc. as required.(Make-polycab/RR Kable/Rhino cable/Eq)
92Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of 3.5core 50 sq.mm direct in groundincluding excavation , sand cushining protective covering and refilling the trench etc. as required.(Make-polycab/RR Kable/Rhino cable/Eq)
93Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of4 core 16 sq.mm Aluminium on surface as required.(Make-polycab/RR Kable/Rhino cable/Eq)
94END TERMINATIONSupplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.3.5C x 300 sq.mm
95Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.3.5C x 185 sq.mm
96Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.3.5C x 50 sq.mm
97Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.4C x 16 sq.mm
98PANELSupply, installation,testing & commissioning of floor mounting front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55 protection with hinged and lockabale doors.CRCA sheets including interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 KA symmetrical for 1 sec at 415 V complete as per specifications, as required and as below : All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used with Indication lamp,C.T , Digital Voltmeter,Digital Ammeter and control fuse etc. complete.MAKE- Legrand / Schneider/ L&T/SIEMENS/Eq.MAIN PANELwith400A 4P MCCB 50KA -1 Nos &,400A 4P Change Over Switch 1Nos as income 80A 4P MCCB 25KA 12Nos, 250A 4P Change over Switch 1Nos, 63A 4P MCCB 25KA 12Nos. with E.C Busbars with 4nos 65KA VSD along with 4nos 32A SP MCB.
99Supply, installation,testing & commissioning of floor mounting front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55 protection with hinged and lockabale doors.CRCA sheets including interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 KA symmetrical for 1 sec at 415 V complete as per specifications, as required and as below : All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used with Indication lamp,C.T , Digital Voltmeter,Digital Ammeter and control fuse etc. complete.MAKE- Legrand / Schneider/ L&T/SIEMENS/Eq.EXT Light DB with 63A 4P MCB (10KA) -1 No as incomer, 1Nos Timer Switch ,20A SP MCB 10KA-12 Nos, 20A DP MCB 10KA 6Nos. as Outgoing with E.C Busbars .
100Supply, installation,testing & commissioning of floor mounting front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55 protection with hinged and lockabale doors.CRCA sheets including interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 KA symmetrical for 1 sec at 415 V complete as per specifications, as required and as below : All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used with Indication lamp,C.T , Digital Voltmeter,Digital Ammeter and control fuse etc. complete.MAKE- Legrand / Schneider/ L&T/SIEMENS/Eq.PUMP Panel Boardwith 63A 4P MCB (10KA) as Incomer , Outgoings-32A 4P MAB 10KA-2Nos, 20 A DP MCB 10KA-3Nos,withE.C Busbars.
101EARTHING Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required
102Supplying and laying 25 mm x 6 mm CU earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required.
103Supplying and laying 25 mm x 6 mm CU earth strip ISI marked on surface or in recess for connection etc as required.
104Providing and fixing 8 SWG CU wire on surface or in recess for loop earthing as required.
105LIGHTENING ARRESTERupply & fixing of lightning Finial 25mm dia x 300 mm long cupper,
106Supplying and laying 25 mm x 6 mm CU earth strip ISI marked on surface or in recess for connection etc as required.
107Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required.
108FIXTURESupply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required.Make-Bajaj/philips/wipro/JAQUAR/Eq.With 5Years Warenty.Ceiling mounted indoortype 24wbatten typeLED Luminaire
109Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required.Make-Bajaj/philips/wipro/JAQUAR/Eq.With 5Years WarentyCeiling/ Wall mounted type 10wBULK HEADLuminaire
110Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required.Make-Bajaj/philips/wipro/JAQUAR/Eq.With 5Years WarentySupply, Installation, testing and commissioning of 10W Mirror Light
111Supply, Installation, Testing and Commissioning of ceiling fan 1200mm sweep USHA ENERGIA, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required.
112Supply, Installation, testing and commissioning of exhaust fan of 230 mm sweep AEROCLEAN LD GBD 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etcas required.
113Supply &fixing of 12W LED Down Light (Surface/Recessed)
114Supply &fixing of LED 36w 2\"x2\" Surface/Recessed Mounted Light
115Supply, Installation, testing and commissioning of45W Premises LED Light.
116Supply &fixing of 5W LED Wall Decorative LIGHT
117Supply &fixing of USHA Wall Fan 300MM HELIX MEGA High Speed /EquivalantWith all accessories.
118PERFORATED TYPE CABLE TRAYSupply and installation of Pregalvanised Perforated type cable trays without cover. The rate shall include bends, Tees, all supporting brackets, anchor fasteners, screws, bolts, nuts etc., including painting of cable trays. Thickness of sheet steel shall be 1.6 mm. Support sizes similar to ladder type trays Size of Cable Tray :300 mm x 50 mm
119SAFETY EQUIPMENTSSupply and installation of Rubber Mats 12mm thick of size 2000mm x 1000mm x 12 mm thick Electrical tested with test certificate.
120Supply and fixing of fire buckets with angular fabricated stand to fix 4 buckets in each stand for Electrical fire protection as per standards of Electrical Inspectorate.
121Supply and fixing of Co2 fire extinguisher with mounting clamps with pressure test certificate .
122Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room.
123Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room.
124DG125 kVA Mahindra/Jackson/Kirloskar Power DG Set– Engine Model – 63905G CPCB II compliant DG, Prime rating, radiator cooled, powered by MAHINDRA/KIRLOSKAR/JAKSON Engine coupled to 125 KVA CG alternator, with Residential Silencer, Anti vibration mountings, exhaust flexible connector, Batteries with cables, complete, with acoustic enclosure and standard Engine safety panel with AMF Panel..
125FIRE FIGHTING SYSTEMFire Pumps and AccessoriesDesign, manufacture, supply, fixing in position, testing and commissioning ofthe following metal enclosed, 2mm thick CRCA Sheet steel, cubical dead front, floor/wall mounting type fire pump control panel, dust and vermin proof, hinged and lockable doors complete with inter connections, cable glands, bonding to earth, painting, cabling and earthing between motors and panel, suitable for 500 volts, 3 phase, 50 cycles, AC supply system. The panel shall be complete with the necessary accessories.
126Supply, installation, testing and commissioning ofterrace booster pump of 450 lpm, 35 mtr head, suitable capacity with cabling, starter all complete. ( MAKE --Kirloskar/Wilo)
127Supply, installation, testing and commissioning of pressure switches (INDFOSS IPS 100 or approved equivalent) including making connections with the control panel and the pressure vessel complete in all respects.( MAKE- INDFOS )
128Providing and fixing 100 mm dia pressure gauge ( MAKE---- H.GURU/EQV STD )
129Cast Iron Butterfly valve (PN1.0) with D.I disc, Hand lever operated, Slim line as per IS: 13095 ISI marked with flanges, bolts, nuts, rubber insertions/ compressed asbestos gasket etc.(MAKE-KARTAR/RONAK/NEW AGE /EQV STD )100 mm Dia
130Cast Iron double flange wafer type type non-returnvalves (dual type) to IS:5312 with G.M.fittinges complete withmatching flanges, rubberinsertion,nuts, bolts and washer etc. of following sizes.(MAKE-KARTAR /DRP /EQV STD)100mm Dia
131Providing and Fixing double flanged ‘Y’ type strainer with cast iron body and stainless steel mesh/ screen SS: 316 complete with companion flanges bolts, nuts, rubber insertions etc. ( MAKE-KARTAR /EQV STD )- 100mm Dia
132Supply and laying PVC insulated and sheathed armoured cable of 1 KV Aluminium conductor including supplying and making end terminations with brass compression glands.(MAKE--FINOLEX / POLYCAB / HAVELLLS )Cu. 2.5 Sq.mm. – 3.5 core for Pump
133Cu. 1.5 Sq.mm. – 2 core instrumentatioin
134Supply and fixing of G.I.Earthing Strip 25 mm x 3 mm with Saddles,screw,sleeve jointing strip etc complete work.( Motor to MCC )
135Providing and fixing of Ball valves, CI wheel of approved quality (screwed end) (Make -Kartar/DRP/Eqv std )25 mm Nominal Bore
13615 mm nominal bore
137M.S. Pipes with Hydrant AccessoriesProviding and Fixing in position black steel (M.S.) pipes bearing IS: 1239 (Medium Class) complete. welded or screwed joints as required, cutting and making good the walls and floors wherever required, complete in all respects (Internal and External works)(MAKE-JINDAL / Eqv Std )25mm Dia
138100 mm dia
139Fire Hydrant AccessoriesProviding and Fixing swinging, wall mounting type 30 mtrs long First Aid Hose Reel of approved quality conforming to IS : 884 and 19mm nominal bore, high pressure hose, FRP/GM shut off nozzle with 6mm outlet and bolts, nuts rubber insertion etc. painted in Fire red colour including cutting and making good the walls wherever required.( MAKE -Swastik/Fire shield/Kartar/Safeguard/Eqv Std )
140Providing and fixing Fire Brigade inlet connection with CI body having 2Nos. gun metal/SS63m male instantaneous inlets conforming to IS 903 fitted with built in check valves, ABS blank caps, G.I. chains, 100 mm, gun metal flanged outlet, 25mm nominal bore gun metal drain valve complete with bolts, nuts, rubber insertions/ compressed asbestos gasket( MAKE -Swastik/Fire shield/Kartar/Safeguard/Eqv Std ) - 2 Way
141Providing & fixing Air vasel withair release valve having rubber ball ( of suitable range and calibrated)on top of each riserwith socket weld / flanged inlet connection(Make -Kartar/DRP/Eqv std) - 250 mm Dia - Core Cutting of Hole in RCC /Wall / Beam and fillingthe same.
142FIRE EXTINGUISHERS (Make-Fire TipsI /Fire Shield)Providing and Fixing carbon dioxide type Fire Extinguisher a) 4.5 kg. capacity
143Providing and fixing ABC fire extinguisher fixed with bolts, nuts and washers complete in all respects.a) 6 kg. capacity
144FF EXIT SIGNAGE With Evacution SystemSITC of Self illuminated Autoglo exit SignsFire Exit with one side arrow size.300x150mm
145FF EXIT SIGNAGE With Evacution SystemSITC of Self illuminated Autoglo exit Signs(DO NOT USE LIFT INCASE OF FIRE)
146PH WORKSProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia CPVC pipe (Riser pipe)
147Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia CPVC pipe ( Down Pipe)
148PVC ASTM Pipes and fittings (Riser & Down)Concealed20 mm dia CPVC Pipe
149Supplying, Fittings & Fixing with all labour, T&P as per specification, the following Brass / CP(Jaquar) /G.M. fittings at appropriate locations along the pipe lines at all floors and at all heights of approved make confirming to relevent IS specification. etc.complete in all respect as per direction of the Engineer in charge.(a)15 mm dia C.P. 2 way Bib Cock (Short body) or Health Processor (Jaquar)CON-CHR-041KN
150Supplying, Fittings & Fixing with all labour, T&P as per specification, the following Brass / CP(Jaquar) /G.M. fittings at appropriate locations along the pipe lines at all floors and at all heights of approved make confirming to relevent IS specification. etc.complete in all respect as per direction of the Engineer in charge.(a) 15 mm dia CP Bib cock ( Long Body)(Jaquar)CON-CHR-107KN
151Supplying, Fittings & Fixing with all labour, T&P as per specification, the following Brass / CP(Jaquar) /G.M. fittings at appropriate locations along the pipe lines at all floors and at all heights of approved make confirming to relevent IS specification. etc.complete in all respect as per direction of the Engineer in charge.(a) 15 mm dia CP Angle stop cock(Jaquar)CON-CHR-053KN
152Supplying, Fittings & Fixing with all labour, T&P as per specification, the following Brass / CP(Jaquar) /G.M. fittings at appropriate locations along the pipe lines at all floors and at all heights of approved make confirming to relevent IS specification. etc.complete in all respect as per direction of the Engineer in charge.(a)15 mm dia C.P. Pillar cock(Jaquar)CON-CHR-011KN
153Supplying, Fittings & Fixing with all labour, T&P as per specification, the following Brass / CP(Jaquar) /G.M. fittings at appropriate locations along the pipe lines at all floors and at all heights of approved make confirming to relevent IS specification. etc.complete in all respect as per direction of the Engineer in charge.Elbow Tap(Plaza/Amber/Aquatic)
154Supplying, Fittings & Fixing with all labour, T&P as per specification, the following Brass / CP(Jaquar) /G.M. fittings at appropriate locations along the pipe lines at all floors and at all heights of approved make confirming to relevent IS specification. etc.complete in all respect as per direction of the Engineer in charge.Contactless Sensor tap
155Supplying, Fittings & Fixing with all labour, T&P as per specification, the following Brass / CP(Jaquar) /G.M. fittings at appropriate locations along the pipe lines at all floors and at all heights of approved make confirming to relevent IS specification. etc.complete in all respect as per direction of the Engineer in charge.600 mm long CP Towel rail
156Supplying, Fittings & Fixing with all labour, T&P as per specification, the following Brass / CP(Jaquar) /G.M. fittings at appropriate locations along the pipe lines at all floors and at all heights of approved make confirming to relevent IS specification. etc.complete in all respect as per direction of the Engineer in charge.(a)CP Soap holder
157Supplying, Fittings & Fixing with all labour, T&P as per specification, the following Brass / CP(Jaquar) /G.M. fittings at appropriate locations along the pipe lines at all floors and at all heights of approved make confirming to relevent IS specification. etc.complete in all respect as per direction of the Engineer in charge. 15 mm dia C.P. Towel Ring
158Supplying, Fittings & Fixing with all labour, T&P as per specification, the following Brass / CP(Jaquar) /G.M. fittings at appropriate locations along the pipe lines at all floors and at all heights of approved make confirming to relevent IS specification. etc.complete in all respect as per direction of the Engineer in charge. 600 mm long C.P. Glass shelf with C.P frame
159Supplying, Fittings & Fixing with all labour, T&P as per specification, the following Brass / CP(Jaquar) /G.M. fittings at appropriate locations along the pipe lines at all floors and at all heights of approved make confirming to relevent IS specification. etc.complete in all respect as per direction of the Engineer in charge.(a)50 mm dia C.P. waste
160Supplying, Fittings & Fixing with all labour, T&P as per specification, the following Brass / CP(Jaquar) /G.M. fittings at appropriate locations along the pipe lines at all floors and at all heights of approved make confirming to relevent IS specification. etc.complete in all respect as per direction of the Engineer in charge.40mm dia GM FW valve
161Supplying, Fittings & Fixing with all labour, T&P as per specification, the following flexible PVC connection pipes and waste pipe making connection with pillar cock, cistern. Wash handbasin at all height and all floors with all jointing materials etc. complete as per direction of the Engineer -in- charge. (a) 450-600 mm long 15mm dia PVC connection pipe
162Supplying, Fittings & Fixing with all labour, T&P as per specification, the following flexible PVC connection pipes and waste pipe making connection with pillar cock, cistern. Wash handbasin at all height and all floors with all jointing materials etc. complete as per direction of the Engineer -in- charge. (a)40 mm dia flexible PVC waste pipe 1 mtr each.
163Supplying, Fittings & Fixing of 10 Ltr. Capacity low level P.V.C cistern white colour,to wall at all floors and at all height with all accessories etc. completein all respect as per direction of the Engineer -in- charge.
164Supplying, Fittings & Fixing of following sizes of porcelain wash hand basin confirming to relevant IS specification of Nycer/ Cera/ Parryware maketo the brick / concrete wall etc. complete as per direction of the Engineer in charge.(a) Standard ( 550x400mm) size basin
165Supplying , fitting and fixing the standard size ofEuropean pattern porcelain wash down water closet confirming to relevant IS specification of Nycer/ Cera / Parryware make having \"S\" or \"P\" trap etc with all required materials, labour T&P etc. complete as per direction of the Engineer in charge.
166Supplying all materials, labour, T&P and fixing bowl pattern urinal including connecting the urinal with waste pipe by means of white lead mixed with chopped hemp etc all complete as per specification and direction of the Engineer in charge.Half stall urinal (Hindware)
167Supplying ,fitting and fixing with all labour and T & P 4mm thick bevelled edge sheet glass mirror (508mmx406) of relevant IS specification to the brick concrete wall with full sheet hard board and CP down shaped screw on wooden /PVC plug etc. complete as per direction of the Engineer in charge.
168Supplying all labour T & P etc for cutting holes in brick masonry wall/ RCC work for passing of GI /pvc Pipes of 15 mm to 50 mm dia and making good to the damages with C.M. (1:4) as per direction of the Engineer in charge.
169Supplying, fitting & fixing ofISI marked PVC,CLASS-B(SWR) pipeswith all materials, labour &T&P on concrete / Brick walls and grounds with nails, bobbins and wooden plugs as required including , scaffolding with proper plumbing fittings for exposed pipescomplete in all respect as per direction of the Engineer in charge.110mm dia UPVC SWRpipes Ground Floor
170Supplying, fitting & fixing of following size of UPVC,CLASS-B(SWR) fittings of ISI marked to UPVCpipes (on concrete / Brick walls and grounds) with all materials labour T&Pincluding cutting of the walls, with supply of nails, bobbins and wooden plugs as required includingscaffolding etc. complete in all respect as per direction of the Engineer in charge.110 mm dia Single Junction with door
171Supplying, fitting & fixing of following size of UPVC,CLASS-B(SWR) fittings of ISI marked to UPVCpipes (on concrete / Brick walls and grounds) with all materials labour T&Pincluding cutting of the walls, with supply of nails, bobbins and wooden plugs as required includingscaffolding etc. complete in all respect as per direction of the Engineer in charge.110 mm dia plain Door Bend
172Supplying, fitting & fixing of following size of UPVC,CLASS-B(SWR) fittings of ISI marked to UPVCpipes (on concrete / Brick walls and grounds) with all materials labour T&Pincluding cutting of the walls, with supply of nails, bobbins and wooden plugs as required includingscaffolding etc. complete in all respect as per direction of the Engineer in charge.110 mm dia \"P\" Trap
173Supplying, fitting & fixing of following size of UPVC,CLASS-B(SWR) fittings of ISI marked to UPVCpipes (on concrete / Brick walls and grounds) with all materials labour T&Pincluding cutting of the walls, with supply of nails, bobbins and wooden plugs as required includingscaffolding etc. complete in all respect as per direction of the Engineer in charge.110 mm dia Off set
174Supplying, fitting & fixing of following size of UPVC,CLASS-B(SWR) fittings of ISI marked to UPVCpipes (on concrete / Brick walls and grounds) with all materials labour T&Pincluding cutting of the walls, with supply of nails, bobbins and wooden plugs as required includingscaffolding etc. complete in all respect as per direction of the Engineer in charge.110 mm dia Cowl
175Supplying, fitting & fixing of following size of UPVC,CLASS-B(SWR) fittings of ISI marked to UPVCpipes (on concrete / Brick walls and grounds) with all materials labour T&Pincluding cutting of the walls, with supply of nails, bobbins and wooden plugs as required includingscaffolding etc. complete in all respect as per direction of the Engineer in charge.75 mm dia Single Junction with door
176Supplying, fitting & fixing of following size of UPVC,CLASS-B(SWR) fittings of ISI marked to UPVCpipes (on concrete / Brick walls and grounds) with all materials labour T&Pincluding cutting of the walls, with supply of nails, bobbins and wooden plugs as required includingscaffolding etc. complete in all respect as per direction of the Engineer in charge.75 mm dia Plain bend
177Fixing rational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts , fixing ball valve etc., including hoisting upto a height of 5 meters above ground level and palcing the tank to the required position etc all complete asper specification and directionof the Engineer In charge.1000 ltrs.Capacity PVC Water storage tank
178Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4984/2016 of the following outside dia for Pressure rating PN-6 including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.110mm dia UPVC alround concrete For Septic tank,soak pit & IC connection
179Providing and fixing Ceramic tiles in floors, treads or steps and landing on 25 mm thick bed of cement mortar (1:1) jointed with neat cement slury mixed with pigment to match the shades of the tiles complete including cost of tiles as directed by the Engineer-in-charge.(30cmx30cm of Kajaria/Somany/Johnson/Orient bell)Ground Floor
180Providing and fixing Ceramic tiles in floors, treads or steps and landing on 25 mm thick bed of cement mortar (1:1) jointed with neat cement slury mixed with pigment to match the shades of the tiles complete including cost of tiles as directed by the Engineer-in-charge.(30cmx30cm of Kajaria/Somany/Johnson/Orient bell)First Floor
181Providing and fixing Ceramic tiles in dados, skirtings and risers of steps on 12 mm thick cement plaster (1:3) jointed with neat cement slury mixed with pigment to match the shades of the tiles complete including cost of tiles as directed by the Engineer-in-charge. (45cmx30cm of Kajaria/Somany/Johnson/Orient bell) Ceramic Tiles for toilet wallGround Floor
182Providing and fixing Ceramic tiles in dados, skirtings and risers of steps on 12 mm thick cement plaster (1:3) jointed with neat cement slury mixed with pigment to match the shades of the tiles complete including cost of tiles as directed by the Engineer-in-charge. (45cmx30cm of Kajaria/Somany/Johnson/Orient bell) Ceramic Tiles for toilet wallFirst floor
183Providing and fixing factory made Rajshri PVC door frame of size 50x47mm with a wall thickness of 5mm,made out of extruded 5mm rigid PVC roam sheet,mitered at corners and joined with 2 Nos.of 150mm long brackets of 15x15mm M.S.square tube, the vertical door frame profiles to be reinforced with 19x19mm M.S.square tube of 19 gauge,EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S.screws of 65/100mm size & 30mm thick factory made Rajshri PVC flush door shutter consisting of panel of hollow PVC profiles of 20mm thickness consisting of frame made out of M.S.Tube of 19 gauge thickness and size 19x19mm inserted inside the hollow section of stiles top & bottom rails and two 19x19mm M.S.Tube horizontally inside the hollow profiles section as an equal distance from top & bottom of door & fixed with hollow profile section using 5mm thick pvc sheet using screw. Hallow PVC profiles shall be filed with 10mm(5mmx2) thickx20mm width on stiles and rails using solvent cement. The inner part shall be laminated with 5mm thick termite proof,water proof & fire retardant pre lam PVC sheet using solvent cement on both the sides of the panel.(S.S.Hinges 100mm,S.S.Tower Bolt 150mm,S.S.Handle 150mm).Complete as per direction of the Engineer-in-charge.Ground floor
184Providing and fixing factory made Rajshri PVC door frame of size 50x47mm with a wall thickness of 5mm,made out of extruded 5mm rigid PVC roam sheet,mitered at corners and joined with 2 Nos.of 150mm long brackets of 15x15mm M.S.square tube, the vertical door frame profiles to be reinforced with 19x19mm M.S.square tube of 19 gauge,EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S.screws of 65/100mm size & 30mm thick factory made Rajshri PVC flush door shutter consisting of panel of hollow PVC profiles of 20mm thickness consisting of frame made out of M.S.Tube of 19 gauge thickness and size 19x19mm inserted inside the hollow section of stiles top & bottom rails and two 19x19mm M.S.Tube horizontally inside the hollow profiles section as an equal distance from top & bottom of door & fixed with hollow profile section using 5mm thick pvc sheet using screw. Hallow PVC profiles shall be filed with 10mm(5mmx2) thickx20mm width on stiles and rails using solvent cement. The inner part shall be laminated with 5mm thick termite proof,water proof & fire retardant pre lam PVC sheet using solvent cement on both the sides of the panel.(S.S.Hinges 100mm,S.S.Tower Bolt 150mm,S.S.Handle 150mm).Complete as per direction of the Engineer-in-charge.First floor

AI Tender Summary

OUR REF NO 37457868
AUTHORITY Government Departments
TENDER VALUE 4.34 Crore
LAST DATE 08-05-2023
Authority
Authority Name Road And Building Department
Work Description Construction Of New Opd Building At Community Health Centre, Polasara Ama Hospital Under 5T Transformation In The District Of Ganjam, Odisha. New Opd Building Under Ama Hospital 5T
Basic Detail
Tender No E.E.-BNJ-RandB-01/2023-24
Bidding Type Tender
Location
City polasara
State Odisha
Key Dates
Publish Date 29 Apr 2023
Submission Date 08 May 2023
Open Date 09 May 2023
Finance
Tender Value 4.34 Crore
Tender Fee 10000
EMD 4.34 Lakhs
Exemption Not Available
Document List
Tendernotice_2.pdf
c749e6e6-f105-4ff6-8635-fd9b53831ca7.html
2nd.CorringendumNotice.pdf
BOQ_436149.xls
DTCN_5.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 29, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
May 08, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 09, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_2.pdf

html

c749e6e6-f105-4ff6-8635-fd9b53831ca7.html

CorringendumNotice

2nd.CorringendumNotice.pdf

xls

BOQ_436149.xls

pdf

DTCN_5.pdf

pdf

Tendernotice_1.pdf

Disclaimer