Tender For Repair/Maintenance Of Summer Appliance I.E. Water Cooler, Desert Cooler, Ac, Refrigerator And Deep Freezers And Repair/Overhauling Of Ceiling Fans, Exhaust Fans, Geysers, Air Circulator, Fresh Air Fan Etc At Military Station Kanasar., kanasar-Rajasthan

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Summer Appliance I.E. Water Cooler, Desert Cooler, Ac, Refrigerator And Deep Freezers And Repair/Overhauling Of Ceiling Fans, Exhaust Fans, Geysers, Air Circulator, Fresh Air Fan Etc At Military Station Kanasar.. Submission Date for this Tender is 02-06-2023. Air Circulators Tenders in kanasar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

37452132
Corrigendum : Tender For Repair/Maintenance Of Summer Appliance I.E. Water Cooler, Desert Cooler, Ac, Refrigerator And Deep Freezers And Repair/Overhauling Of Ceiling Fans, Exhaust Fans, Geysers, Air Circulator, Fresh Air Fan Etc At Military Station Kanasar.
Open Tender
Indian
Rajasthan
kanasar
02-06-2023

Tender Details

Repair/Maintenance Of Summer Appliance I.E. Water Cooler, Desert Cooler, Ac, Refrigerator And Deep Freezers And Repair/Overhauling Of Ceiling Fans, Exhaust Fans, Geysers, Air Circulator, Fresh Air Fan Etc At Military Station Kanasar.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-May-2023 BOQ BOQ 26-05-2023
2 26-May-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 18000.0 /-
Tender Value
INR 9 Lakhs /-

BOQ Items

Name of Work : Repair/Maintenance of summer appliance i.e. water cooler, desert cooler, AC, refrigerator & deep freezers and repair/overhauling of ceiling fans, exhaust fans, geysers, aircirculator, fresh air fan etc at Military Station Kanasar.
Sl. No. Item Description
1Taking down and dismantling of ceiling fan 1200mm/1400mm sweep of any make new/old model by opening the cover, separating down rod, rotor and stator assembly, locating the fault and making the fan fully in serviceable condition including replacing the defective worn out screw of the cover, split pin, oiling and grassing etc, including repainting with synthetic enamel paint by spraying including filling cavities with filler, re-writing the MES No. as of original size with stencil, including cleaning of the rating plate with the thinner etc complete all as specified & as directed. Note : Rewinding and parts such as bushing, bearings, condensers, ‘D’ clamps with nuts, quarter pin & rubber seal, down rod, PVC Canopies, flexible wire & shaft etc shall be measured and paid separately under the respective items here-in-after.
2M&L for re-winding mortar of ceiling fan any make/model size 1400MM sweep with super enameled copper winding wire of existing specification, gauge & weight conforming to IS including insulating material & varnishing the mortar windings with good quality varnish complete all as specified & as directed. Make of winding wire : MILAN/ATLAS/CHETAK/DEVIDAYAL
3M&L for re-winding mortar of ceiling fan any make/model size 1200MM sweep with super enameled copper winding wire of existing specification, gauge & weight conforming to IS including insulating material & varnishing the mortar windings with good quality varnish complete all as specified & as directed. Make of winding wire : MILAN/ATLAS/CHETAK/DEVIDAYAL
4S&F in replacement of ball bearing of suitable size for ceiling fan 1200mm/1400mm sweep complete all as specified & as directed. Make : NBC/SKF confirming to IS
5S&F in replacement of brass bush suitable for ceiling fan any make/model all as per original size/shape/type conforming to IS complete all as specified & as directed.
6S&F in replacement of canopy suitable for ceiling fans of any make, type and size complete all as specified & as directed. Make : Usha/Bajaj/Khaitan/Orient/CG/Polar/Havells.
7S&F in replacement of shaft of ceiling fan as per existing size and shape complete all as specified & as directed.
8S&F in replacement of fan blades for 1200mm sweep fan as per sample kept in AGE’s Office complete all as specified & as directed.
9S&F in replacement of capacitor 230V, 50 Hz, 2.5 MFD for ceiling fan complete all as specified & as directed. Make : Asain/Usha/Universal/Tibcon
10S&F in replacement down rod one foot long suitable for 1200/1400mm sweep of ceiling fan as required at site complete all as specified & as directed.
11S&F in replacement ‘D’ clamp with nuts, check nuts, quarter pin and rubber reel suitable for 1200/1400mm sweep of ceiling fan as required at site complete all as specified & as directed.
12S&F in replacement for PVC insulated and over all PVC sheathed copper conductor wire of size 1.5Sqmm x 3 core, flexible wire ISI marked, for connection of fan from ceiling rose to fans complete all as specified & as directed. Make : Finolex/Polycab/Havells
13S&F in replacement Ceiling cover plate circular type for ceiling fans of any make, type and size complete all as specified & as directed. Make : Acchor/Havells/Usha/Khaitan/Orient
14S&F in replacement fan regulator Paino type for ceiling fans of any make, type and size complete all as specified & as directed. Make : Anchor/Havells/Kingal/Khaitan/Orient
15EXHAUST FAN / AIR CIRCULATOR FRESH AIR FAN
16Taking down & dismantling of PVC Air Freshener Fans/Exhaust fan 200mm/300mm/450mm sweep of any make new/old model by opening the cover , separating the down rod, rotor and stator assembly, locating the faultand making the exhaust fan fully in serviceable condition including replacing the defective worn out screw of cover, split pin, oiling and greasing etc, including repainting with synthetic enamel paints by spraying including filing cavities with filler, rewriting of MES No. as original, reassembling the fan and testing complete to the satisfaction of the Engineer-in-Charge. Note : Rewinding and parts such as bushing, bearing, condensers , D clamps with nut, quarer pin and rubber seal, down rod, PVC canopies,flexible wire & shaft shall be measured and paid for separately under the respective items here-in-after.
17M&L for re-winding of PVC Air Freshener fans 200mm sweep any make/model size with supper enameled copper winding wire of size 35/36 SWG or as per existing size of wire confirming to IS including varnishing the motor windings with good quality varnish complete all as specified & as directed. Make of winding wire : MILAN/ATLAS/CHETAK/DEVIDAYAL
18M&L for re-winding of exhaust fan 300 mm sweep any make/model size with super enameled copper winding wires of size 35/36 SWG or as per existing size of wire confirming to IS including varnishing the motor windings with good quality varnish complete all as specified & as directed. Make of winding wire : MILAN/ATLAS/CHETAK/DEVIDAYAL
19Ditto all as per serial Item No. 18.00 here-in-before but size 450 mm sweep.
20S&F in replacement of ball bearing suitable for exhaust fan of any sweep complete all as specified & as directed. Make : NBC/SKF conforming to IS.
21S&F in replacement of brass bush suitable for exhaust fan any make/model all as per original size/shape/type conforming to IS complete all as specified & as directed.
22S&F in replacement of shaft of exhaust fan any make/model all as per original size/shape/type conforming to IS complete all as specified & as directed.
23S&F in replacement of capacitor 230V, 50Hz, 2.5 MFD for exhaust fan complete all as specified & as directed. Make : Asain/Usha/Universal/Tibcon
24S&F in replacement of capacitor 230V, 50Hz, 4.0 MFD for exhaust fan complete all as specified & as directed. Make : Asain/Usha/Universal/Tibcon
25S&F in replacement of rust proof rigid plastic body with louvers shutter complete with nuts, bolts and washer suitable for PVC Air freshener fans of size 200mm to 250mm sweep complete all as specified & as directed.
26S&F in replacement of louvers shutter complete with nuts, bolts and washers suitable for PVC Air freshener fan of size 300mm to 450mm sweep complete all as specified & as directed.
27S&F in replacement of Plastic fan blades for 200mm sweep exhaust fan as per sample kept in AGE’s office complete all as specified & as directed.
28GEYSERS
29Taking down unserviceable geyser including bushes, washers, mounting rubbers, nuts, bolts and clamps from existing place and re-fixing at same place after repair complete all as specified & as directed.
30S&F in replacement high density polythene pipe (HDPE) connection arrangement with pipe of pressure rating 2.5kgf/cm2, 15mm bore 30cm to 45 cm long with brass unions one (Chromium plated) one on each side in repair to geyser 25/50 liters pipe shall be as per IS complete all as specified & as directed.
31S&F in replacement of thermostat switch ISI marked to geysers 25/50 liters complete all as specified & as directed.
32S&F in replacement heating element ISI marked of rating 1.5KW capacity including washers for 25 ltrs capacity geyser complete all as specified & as directed. Make : THETA/ALERT
33S&F in replacement plug top, 3pin, 15 Amps, 230 Volts, ISI marked, complete all as specified & as directed. Make : Anchor/Legrand /Havells
34S&F in repair pressure release safety valve for geysers spring loaded suitable for 15mm pipe chromium plated complete all as specified & as directed.
35S&F in replacement bib taps, cast copper alloy with crutch of butter fly handle screwed down, screwed for iron pipe of for brass ferrule, fancy type and fixed of size 15 mm dia complete all as specified & as directed.
36Supply&.Fixing in replacement Switch piano type 230/ 250V grade on top covers (catered in point wiring above) Single pole, one way 15 Amp rating complete all as spacified and directed.
37S & Fixing in replacement Socket outlet2 in 1, 3 pin, 5 and 15 Amp flush type multipurpose use230/250 Volts grade complete all as spacified and directed.
38S&F in replacement Stainless steel inner tank suitable for geyser of capacity 25 Ltr complete all as specified and directed.
39S&F in replacement Outer tank madeof MS sheet powder coated suitable for geyser of capacity 25 Ltr complete all as specified and directed.
40S & F in replacement of neon indicator lamp round or rectangular type. complete all as specified & as directed.
41S & F in replacement of Geyser bottom assembly kitof 7 hole/9 Hole/6 hole as per existing complete including, bolts and rubber gasket for 25/50 litres capacity geysers as per requirement with the same make which is to be replaced complete all as specified & as directed.
42Supply and fix in replacement for PVC insulated and over all PVC sheathed copper conductorwire of size 2.5 Sqmm x 3 core,flexible wireISI marked,complete all as specified and directed by Engineer in charge. Make : finolex/polycab/Havells
43Summer Appliances
44Dismantling/removing the defective un-serviceable compressor of any capacity for window type AC, split type AC, refrigerators, water coolers, Deep freezers etc complete, all as specified & as directed.
45Supply installing, testing & commissioning new compressor of water cooler capacity 40/80 litres duly charged with fresh mafron gas etc, complete all as specified & directed. Make :- Voltas / Shriram / Tecumseh / Kirloskar as per existing make at site. Note:- Guarantee card with purchase voucher of original manufacturer shall be produced by the contractor before payment.
46Ditto all as per Item No. 45.00 here-in-before, but for 150/150litre capacity water cooler.
47Ditto all as per Item No. 45.00 here-in-before, but for split type AC 2 Ton capacity.
48Ditto all as per Item No. 45.00 here-in-before, but for split type AC 1.5 Ton capacity.
49Ditto all as per Item No. 45.00 here-in-before, but for refrigerator 310 litre capacity.
50Ditto all as per Item No. 45.00 here-in-before, but for deep Freezer 300 litre capacity.
51M&L for detecting the gas leakage, rectifying the defects vacuuming and charging fresh Gas & commissioning and testing the window/ Split type Air conditioner unit 1.5/2.0 Ton capacity complete, all as specified & as directed.
52All as per serial item No.51.00 here-in-before, but of 310 litre capacity refrigerator.
53All as per serial item No.51.00 here-in-before, but of water cooler of any capacity.
54Ditto all as per Item No. 51.00 here-in-before, but for deep Freezer of any capacity.
55Removing of existing window /split type AC 1.5 / 2.0 ton capacity mounting, cleaning of evaporator and condenser with alkaline based solution, washing of AC , oiling of fan motor and re-fixing on mounting, including provision for making opening air tight and dust proof including testing and commissioning, complete, all as specified & as directed.
56M & L for rewinding of electricmotor blower fan motor of 1.5/2.0 ton window/ split type AC 1400 RPM 220 V 50 C/Swithsupper enameled copper wire of suitable size including, replacement of shaft, bushes, capacitor and testing on load all as directed.
57Supply and fix in replacement remote control complete for split type ACs 1.5 to 2 ton capacity complete all as specified and directed.
58Supply and fix in replacement front grill suitable for 1.5/2 ton window type Ac complete all as specified and directed. Make Carrier /Usha /LG/Bluestar/Voltas .
59Supply and fix in replacement Plastic filter for window type AC 1.5 ton capacity complete all as specified and directed.
60Supply and fix in replacement Blower Motor, single phase 230 Volts 1500 RPM,suitable for 1.5 TR Window type Air Conditioner (Make : AUE / USHA/ LG/Voltas)
61Supply and fix in replacement Blower Motor, single phase 230 Volts 1500 RPM,suitable for 1.5/2.0 TR Split type Air Conditioner (Make : AUE / USHA/LG/Voltas)sha
62Supply and fix in replacement Thermostatic switch with knob suitable for window type AC 1.5 TR complete all as specified and directed. (Make : INDFOS / RENUTRAL )
63Supply and fix in replacement fan blade suitable for out door unitofSplit type ACcapacity 1.5/2.0 complete all as specified and directed. Make:-Carrier/voltas/LG
64Supply and fix in replacement blower complete with fins suitable for in door unitofSplit type ACcapacity 1.5/2.0 complete all as specified and directed. Make:-Carrier/voltas/LG/Bluestar
65Supply & fix in replacement of copper tubing including cutting brazing, flaring and testing of size 1x4”x22SWG in required length including insulating piping complete all as specified and directed.
66S&F in replacement Running capacitor 45 to 50 MFD 230 volts, 50 Hz for window/split AC complete all as specified & as directed. Make : Tibcon/ Sharda / Epcos/ Usha
67S&F in replacement Starting capacitor 100 to 120 MFD 230 volts, 50 Hz for window/split AC, complete all as specified and directed. Make : Tibcon/ Sharda / Epcos/ Usha
68Taking down carefully the following parts from the existing AC andproviding new accessories / parts as per existing make complete, all as specified & as directed:-
69Contactor for split AC (1.5 / 2.0 TR)
70PCB for split AC (1.5 / 2.0 TR)
71Starting relay for split AC (1.5 / 2.0 TR)
72S&F in replacement Over load protector (OLP) suitable air conditioner 1.5 ton/ 2.0 Ton capacity complete all as specified & as directed. Make : SRIRAM / Ranutrol/ Indfoss
73Taking down carefully the following accessories/ parts from existing water coolers and providing new accessories / parts in theses water coolers as per existing make & details given here-in-after :-
74Filter copper
75Capillary Tube of copper existing size as per sample approved by engineer-in- charge.
76PVC water outlet pipe 15mm dia including clamps
77Drain pipe of same quality , length and dia as per sample approved by engineer-in- charge.
78S&F new condenser of size 12""x12""/12""x15""
79Taking down defective fan motor from water coolers, dismantling the old burnt winding from the motor and rewinding with super enameled copper wire as per existing size including replacement of shaft, bushes mounting rubbers, nuts bolts and re-fixing after reassembling and testing in existing water coolers for under mentioned fan motors etc complete all as specified & as directed. Make of winding wire :- Milan / Chetak Note :- The unit quoted rate shall be deemed to be included replacement of minor après such as rubber, nuts washers insulating materials and clamps etc.
80Fan motor of capacity 1/10 HP 230Volts, Single Phase
81Fan motor of capacity 1/35 HP 230Volts, Single Phase
82Taking down carefully fan motor from existing water coolers and providing new fan motor 1/10 HP 230 Volts, 50 HZ including replacement of mounting legs complete all as specified & directed. Make of Fan motor :- Frac Master / Polor/Usha
83S&F in replacement push cock (stainless steel) for water cooler as per existing complete all as specified & as directed.
84S&F in replacement thermostat for water cooler of capacity 40/80 Ltr complete all as specified & as directed. Make :Indfoss/Denfoss
85S&F in replacement Starting capacitor 60 to 80 MFD 230 volts, 50 Hz for water cooler complete all as specified & as directed. Make : KELTRON / USHA / Tibcon
86S&F in replacement ofrelay with OLP suitable for water cooler complete all as specified & as directed. Make : Annapurna / Hi Tech
87S&F in replacement Flexible Core PVC insulated with stranded copper conductor 40 / 0.0076 Sqmm 3 core 600/1100 V ISI Marked complete all as specified & as directed. Make : Finolex/Havells/Plaza
88S&F in replacement 20mm bore PVC float valve for water coolers as per existing complete all as specified & as directed.
89Taking down carefully the following accessories / parts from existing refrigerator of any make of capacity 310 litres supply & fixing accessories / parts as per existing in the same refrigerators as under complete:-
90Evaporator for 310litre refrigerators any make.
91Filter copper of any make.
92Capillary tubes of copper existing sizes as per sample approved by engineer-in- charge.
93Thermostat for refrigerator 310 litre capacity. Make:- Indfoss
94Relay for refrigerator 310 litre capacity as per sample approved by engineer-in- charge.
95Vegetable tray for refrigerator of 310 litre capacity as per sample approved by engineer-in- charge.
96M&L for painting of water cooler of capacity 40/80 Ltr external body with one coat of synthetic enameled gray paint complete with spray painting after proper dusting, cleaning and scrapping old painted surfaces including writing SM/MES No complete all as directed by the Engineer-in-Charge.
97M&L for painting of deep freezer of capacity 300 Ltr external body with one coat of synthetic enameled gray paint complete with spray painting after proper dusting, cleaning and scrapping old painted surfaces including writing SM/MES No complete all as directed by the Engineer-in-Charge.
98M&L for painting of desert cooler’s external body, fan & pump with one coat of synthetic enameled gray paint & internal body with synthetic enameled black paint complete with spray painting after proper dusting, cleaning and scrapping old painted surfaces complete all as directed by the Engineer-in-Charge.
99Supply only Submersible pump 1.65 mtr head , 18 watt, 230 volts, 50 Hz withfor Desert coolers including taking down old one all as specified and directed. Make :- KHAITEN / SUMMER KING/Shakti
100S&F in replacementFanmotor kit 1/6 to 1/8 HP 230 Volts 50 Hz for Desert cooler including replacement of mounting legs etc complete all as specified and directed. Make :- KHAITEN / SUMMER KING/Shakti
101Taking down carefully fan motor 1/6 to 1/8HP 230 volts, 50Hz from existing desert coolers and re-fixing the same fan motor after rewinding with super enameled copper wire of existing size including replacement of mounting legs complete all as specified & directed. Make of winding wire :- Milan / Chetak
102S&F in replacement of capacitor for desert cooler 4MFD 230 volts complete all as specified and directed. Make:- Asian / Tibcon/ Usha/ Universal
103S&F in replacement of front grill including nuts & bolts and washers suitable for 18/20" sweep desert coolers complete all as specified & as directed.
104S&F in replacement wooden shelving padfor Desert cooler each set weighting not less than 500 grams etc complete all as specified & as directed. Note :Each set have a three pad.
105S&F in replacement supporting jali for desert coolers etc complete all as specified & as directed. Note :Each set have a three jali.
106S&F in replacement fan blades mode of aluminium for desert cooler etc complete all as specified and directed.
107Supply and fix in replacement Side Panels/filter panels made of galvanized iron Sheet 0.67 mm thickfor 4000 Cum/Hr Desert Cooler complete all as specified & as directed by Engr-in-charge.
108Supply and fix in replacement fan motor fixing kit/ assembly made of flat iron and clamps including required size of nuts and bolts suitable ofr metal body desert coolers of capacity 4000Cum/Hour complete all as specified & as directed by Engr-in-charge.
109Supply and fix in replacement PVC flexible pipe (from vertical pump to distributer and distributer to panel) 15mm dia for Desert cooler including 3 way distributor junction tee set etc complete all as specified & as directed by Engr-in-charge.
110Supply and fix in replacement Desert Cooler Fan regulator for 4000 to 5000 cum/Hr Desert Cooler capacity of various makes all as per existing etc complete all as specified and directed. Make:- KHAITAN / SUMMER KING/Shakti
111Supply and fix in replacement Switch Piano 5 Amp single pole 230 volt etc complete all as specified and directed by Engr-in-charge. Make :- Anchor/kinjal/plaza/Cona/SSK/Leader
112S&F in replacement PVC Lead wire 1.5 sqmm stranded copper conductor 1.5 sqmm 3 core ISI Marked etc complete all as specified and directed by Engr-in-charge. Make : Finolex, Havells
113S & F in replacement of Plug top for desert cooler 3 pin 5 Amps, 230 Volt AC, ISI marked etc complete all as specified and directed by Engr-in-charge. Make :Anchor / Plaza
114S&F in replacement of U/S single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 25 Amps MCB, 240 volt complete all as specified and directed.Make : Havells/L&T/HPL
115S & F in replacement MCB suitable for 6 to 32 Amps, 240 Volt AC supply, SPN, with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed. Make:-Legrand /L&T/ Indo Asain / C&S
116Supply and fix Evaporative air cooler in steel body (Desert Cooler) with propeller type cooler fan with motor(ISI marked)1400 RPM three speeds, nominal capacity 4000 Cum/Hour, fan size 450 mm, type of blades- plastic (HIP), submerssible water pump, filter pads, Power consumption 250 watt (maximum),electric driven, single phase, 230 Volts, 50 Hz, capacitor of suitable capacity, including all accessories, complete all as specified and directed. NOTES :- (i) Filter panels, front of the cooler body shall be made of 0.67 mm galvanized steel sheet. The sump tank and rest of the body shall be made of 1.00 mm thick galvanized steel sheet. The galvanized steel sheet shall be ISI marked and shall have zinc coating not less than 100 gm/sqm and shall confirm to IS :277. (ii) All internal surfaces including inside of the tank, fan blades, motor body, pump, pump body and frame shall be painted with water resistant paint conforming to IS:9862. The outer surface of cooler shall be spray painted with synthetic enamel paint of approved shade/tint. (iii) The desert cooler shall be fitted with adjustable grill with seprate on/off switch of 5/6 Amp rating (ISI marked)for cooler fan and water pumpand three stage speed regulator for three speed cooler fan motor. (iv) Suitable nylon bushes shall be provided in the grill for easy and smooth movement of louvers. (v) The filter pad shall contain wool. The filter pads shall be fixed over the panel and secured by clamping guard of galvanized wire of 1 mm dia (approx) and net size 100 mm (approx) , square/rectangular. The wire guard shall be fixed in the clamps to avoid any sagging. (vi) The inside wiring connection shall be through suitable non-ferrous thimbles and the live contacts of rotary switch shall be protected by suitable enclosures of insulating material. The electrical cords of the motor and the pump shall be sheathed type. (vii) The cooler shall be provided with front/back filling arrangement and with 3 core copper stranded conductor size 23/0.0076 cable connecting cord (ISI marked) of 1.50 mtr length fitted with 3 pin moulded plug top of 5/6 amp rating. (viii) PVC pipe 15 mm bore shall be heavy duty high density.
117(ix) Overall minimum dimensions including water tank (sump) of the cooler shall be as under :- (a) Width - 660 mm (measured at front side) (b) Height - 812 mm (measured at front side) ( c) Length - 660 mm (x) Cooler fan with motor shall be of make :- Khaitan/Usha/Bajaj/Crompton/Orient/ Polar/ Havells. Make of other material such as switches, copper cord etc shall be specified in particular specification/Appendices. (xi) Above aspects shall deemed to be included in quoted rates. (x) Cooler fan with motor shall be of make :- Khaitan/Usha/Bajaj/Crompton/Orient/ Polar/ Havells. Make of other material such as switches, copper cord etc shall be specified in particular specification/Appendices. (xi) Above aspects shall deemed to be included in quoted rates. (ix) Overall minimum dimensions including water tank (sump) of the cooler shall be as under :- (a) Width - 660 mm (measured at front side) (b) Height - 812 mm (measured at front side) ( c) Length - 660 mm