Tender For Repair To Flooring, Plastering, Tiling, Repair To Leakage Seepage, Overhead Tank, Periodical Services And Other Misc B/R Works At Af Stn Chandinagar In Aor Of Ge (Af) Faridabad, Baghpat-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair To Flooring, Plastering, Tiling, Repair To Leakage Seepage, Overhead Tank, Periodical Services And Other Misc B/R Works At Af Stn Chandinagar In Aor Of Ge (Af) Faridabad. Submission Date for this Tender is 02-06-2023. Civil Work Tenders in Baghpat Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

37452128
Corrigendum : Tender For Repair To Flooring, Plastering, Tiling, Repair To Leakage Seepage, Overhead Tank, Periodical Services And Other Misc B/R Works At Af Stn Chandinagar In Aor Of Ge (Af) Faridabad
Open Tender
Indian
Uttar Pradesh
Baghpat
02-06-2023

Tender Details

Repair To Flooring, Plastering, Tiling, Repair To Leakage Seepage, Overhead Tank, Periodical Services And Other Misc B/R Works At Af Stn Chandinagar In Aor Of Ge (Af) Faridabad

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-May-2023 Corrigendum Date 26-05-2023
2 26-May-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work:REPAIR TO FLOORING, PLASTERING, TILING, REPAIR TO LEAKAGE SEEPAGE, OVERHEAD TANK, PERIODICAL SERVICES AND OTHER MISC B/R WORKS AT AF STN CHANDINAGAR IN AOR OF GE (AF) FARIDABAD
Sl. No. Item Description
1Taking down of old existing roof treatment of any description incl scrube and remove loose concrete, brick tiles, mud fuska, plaster, bitumen, oil grases and any other materials that might effect adhesion by wire brushing the surface and cleaning of the surface throughly with water and disposed off old materials from site complete all as specified and directed by Engineer-in-Charge.
2M&L for50 mm thick cement concrete 1:2:4 type B-0 ( using 12.5 mm graded stone aggregate) as in padding/ base on roofcomplete all as specified and directed by Engineer-in-Charge.
3M&L for 20 mm thick plastering in CM 1:4 on RCC roof slab, finish even and smooth for receive water proofing APP membrane using WPC @ 3% by weight of cement complete all as specified and directed by Engineer-in-Charge. Note : WPC will be measured and paid separately.
4Supply only Integral water proofing compound complete all as specified and directed by Engineer-in-Charge.
5M/L for preparation of the plastered roof surfaces and fix the APP polymeric water proofing membrane of minimum 3 mm thickness & weighing not less than 3.0 kg / Sqm of make : IWL, STP, BENGAL BITUMENas approved by GE, black finished reinforced with non-woven ployster 160 gsmmatt with a thermofusible finish laid over primer conforming to IS:3384-1965 @ 0.5 kg/Sqm and thereafter apply compitable hot blownbitumen 85/25 @ 1.20 kg/Sqm torching overlaps with a propane or a butane gas torch with a overlap of 75 mm at the sides and 100 mm at the end sealing complete all as specified and directed by Engineer-in-Charge.
6Disconnecting existing PVC tanks of capacity exc 250 & n exc 500 ltrers, setting aside (or loweringif required)for repairs, Cleaning and removing all scale and dirt, etc. from tanks and form mouths of circulating pipes, etc. and hoisting if required reconnecting and re-fixing the same in position and restore water supply to accommodation complete all as specified and directed by Engineer-in-Charge.
7Disconnecting existing PVC tanks of capacity exc 500 & n exc 1000 ltrers, setting aside (or loweringif required)for repairs, Cleaning and removing all scale and dirt, etc. from tanks and form mouths of circulating pipes, etc. and hoisting if required reconnecting and re-fixing the same in position and restore water supply to accommodation complete all as specified and directed by Engineer-in-Charge.
8Supply and fixing in repair for 15 mm bore steel water tubing galvanised 15mm bore, medium grade fixed to walls and ceiling or in floor complete all as specified and directed by Engineer-in-Charge.
9Supply and fixing in repair for 20mm bore steel water tubing galvanised, medium grade fixed to walls and ceiling or in floor complete all as specified and directed by Engineer-in-Charge.
10Supply and fixing in repair for 25 mm bore steel water tubing galvanised, medium grade fixed to walls and ceiling or in floor complete all as specified and directed by Engineer-in-Charge.
11Demolition of brick work built in cement mortar in any position including all quoins, arches & pillars etc complete all as specified and directed by Engineer-in-Charge.
12M&L for brick work withsub class "B"bricksstraight or curved on plan exceeding6m mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
13Taking down cement plaster including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
14Material and labour for 15mm thick rendering in CM 1:4 mixed with WPC @ 3 % WPC on fair faces of brick or concrete surfaces of walls finished even and smooth w/o using extra Cement complete all as specified and directed by Engineer-in-Charge.
15M&L for preparation of newly plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed by Engineer-in-Charge.
16S&F in repair PVC (SWR) single socketed rain water pipe 75 mm bore in any length with rubber ring joints fixed towalls/roof incl brackets/clamps etc complete all as specified and directed by Engineer-in-Charge.
17S&F in repair PVC (SWR) single socketed rain water pipe 110 mm bore in any length with rubber ring joints fixed towalls/roof incl brackets/clamps etc complete all as specified and directed by Engineer-in-Charge.
18Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed by Engineer-in-Charge.
19S/F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
20Dismantling water tanks and removing to store of capacity n exc 500 ltrs complete all as specified and directed by Engineer-in-Charge.
21Supply and fixing 500 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engineer-in-Charge in SSR Part I.
22Dismantling water tanks of capacity exc500 and n exc 1000 ltrs and removal to contractor"s store yard, complete all as specified and directed by Engineer-in-Charge.
23Supply and fixing 1000 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engineer-in-Charge in SSR Part I
24Dismantling wall and ceiling boards (fibre, pulp, insulation etc) any thickness, including cover fillets and grid frame work complete all as specified and directed by Engineer-in-Charge.
25M & L anodised aluminium snap grid frame work of size 605 x605mm for false ceiling including hanger 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5 mm dia 40mm long complete all as specified and directed by Engineer-in-Charge.
26M&L for 8 mm thick Exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid complete all as specified and directed by Engineer-in-Charge.
27M&Lsolid PVC Wall Lining/panelling consisting of 5mm thick prelaminated/Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed by Engineer-in-Charge.
28M&L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed by Engineer-in-Charge.
29M&L for preparation of old treated plastered surfaces of wall by brooming down or steel wire brushing scrubbing down smoke soot, moulds, moss and efflorescence salts and treating oil and greasy spots removing dust, dirt andallloose scales of existing treatment and applying one coat of white wash on wall complete all as specified and directed by Engineer-in-Charge.
30All as per item No 29 above but on ceiling complete all as specified and directed by Engineer-in-Charge.
31M&L for preparation of old treated plastered surfaces of wall by brooming down or steel wire brushing scrubbing down smoke soot, moulds, moss and efflorescence salts and treating oil and greasy spots removing dust, dirt andallloose scales of existing treatment and applying one coat of oil bound distemper on wall complete all as specified and directed by Engineer-in-Charge.
32All as per serial item No 31 above but two coats of oil bound distemper on wall complete all as specified and directed by Engineer-in-Charge.
33M&L for preparation of old treated plastered surfaces of ceiling by brooming down or steel wire brushing scrubbing down smoke soot, moulds, moss and efflorescence salts and treating oil and greasy spots removing dust, dirt andallloose scales of existing treatment and applying one coat of oil bound distemper on ceiling complete all as specified and directed by Engineer-in-Charge.
34M&L for Complete removal of existing treatment from walls, fins, chajja etc shall include brooming down or steel wire brushing, scrubbing down smoke soot, moulds, moss and efflorescence salts and treating oil and greasy spots and removing debris/ malba to low lying area out side of MOD land and applying 3 to 5 mm thick a layer of Birla white wall care water proof putty on scrapped/uneven surfaces to match with the existing surfaces before application of primer/distemper andapplying two coats of oil bound distemper over a coat of primercomplete all as specified and directed by Engineer-in-Charge.
35M&L for preparation of old treated plastered surfaces of wall by brooming down or steel wire brushing scrubbing down smoke soot, moulds, moss and efflorescence salts and treating oil and greasy spots removing dust, dirt andallloose scales of existing treatment and applying one coat of cement base paint on wall complete all as specified and directed by Engineer-in-Charge.
36All as peritem No 35 above but two coats of cement based paint on wall complete all as specified and directed by Engineer-in-Charge.
37M&L for preparation of old wooden surface of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
38M&Lfor preparation of old painted steel surfaceof any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
39M&Lfor applying one or more coats of French polishing on old wood surfaces of any description, width or girth including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
40M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick or concrete surfaces of walls, facia etc to be finishedeven and smooth (w/o using extra cement) complete all as specified and directed by Engineer-in-Charge.
41M&L for preparing newly plastered surfaces and applying two coats of distemper oil emulsion including priming plastered and other surfaces with chalk whitening preparatory to distempering on surfaces of walls complete all as specified and directed by Engineer-in-Charge.
42M&L for preparation of old treated plastered surfaces of wall by brooming down or steel wire brushing scrubbing down smoke soot, moulds, moss and efflorescence salts and treating oil and greasy spots removing dust, dirt andallloose scales of existing treatment and applying two coats of exterior acrylic emulsion water based (weather proof coat) paint on wall complete all as specified and directed by Engineer-in-Charge.
43Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-Charge.
44M&L for Steel work in tubular trusses and purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed by Engineer-in-Charge.
45M&L for framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 grade 165 quality A complete all as specified and directed by Engineer-in-Charge.
46M&L for MS work as in post and strutt and fencing, drilled and countersunk for balusters running bars for doors balusters,noising to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts,posts and struts in fencing including cutting tops to shape as directed drilling hoes nothcing for wire etc flat iron fillets ( for securing wire mesh ) including all necessary drilling bolting or riveting etc. and similar work conformingto Fe - 290 Gde E - 165 complete all as specified and directed by Engineer-in-Charge.
47M&L for in applying two coats of synthetic enamel paint over a coat of red oxide primer to new steel and iron surfaces over 10cm in width or girth including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
48Demolition of cement concrete of any description and in any position not otherwise specificially provided for complete all as specified and directed by Engineer-in-Charge.
49M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate as in for fixing angle iron and coping including necessary form work) complete all as specified and directed by Engineer-in-Charge.
50M&L for applying Twocoats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489: 2004 ,Alkali & fungal resistance ,dirt resistance exterior paint of required shade ( Company Depot Tinted ) with silicon additives @ 1.43 litre/ 10 Sqm over and including priming coat of exterior primer applied @ .90 litre /10 Sqm over new surfacescomplete all as specified and directed by Engineer -in -Charge.
51M&L for applying/finishing walls with Premium Acrylic smooth exterior paint with Silicone additives of required shade : NEW work( Twocoats applied @ 1.43 ltr/10 Sqm over and including priming coat of exterior primer applird @ 2.20 Kg/10 Sqm complete all as per specified and directed by Engineer -in -Charge
52M&L for distempering with 1st quality acrylic distemper (ready mixed ) having VOC content less than 50 gms/ltr ,of approved manufacturer , of required shade and color complete , as per manufacturer specification . Twocoats on new work complete all as specified and directed by Engineer-in-Charge.
53M&L forPVC 30mm thick Prelaminated/plain Perforated PVC False Ceiling made of5mm wall thickness PVC perforated sheet of size 600mm x 600mm. On 25mm Glasswool/ Rockwool5.0mm (±0.25) Prelam perforated PVCsheet of Density 600 Kg /Cbm manufactured by an ISO-9001 - 2015 certified company, is stuck with glasswool on one side with suitable adhesive. The panel is inserted in a frame made of anodised Aluminum or GI"T" section of size 1""x1"" (25mm x 25mm) in square type grid of size 2" x 2" (600mm x 600mm).The aluminium/ GI framework is supported from the ceiling with the help of "J" hook and G.I. wire / 6mm M.S. rods of required sizes to maintain proper level. The aluminium/GIframework is supported on side wall with the help of aluminium/GI "L" section of size 1"x1" (25x25mm) angles. Complete as per direction of Engineer-in-charge, manufacturer"s specification & drawing complete all as specified and directed by Engineer-in-Charge.
54S&F for 6 mm thick selected colour/shade aluminium composite panel/sheets for interior/exterior wall cladding upto G+2 storeyed external wall surface complete all as specified and directed by Engineer-in-Charge.
55S&F in repair stainless steel letters (English/Hindi) and grade SS-204 consisting of 80 mm high 50 mm width and 25 mm depth hollow walls fixed on wall surface or on ACP sheet board of any description using SS screw of suitable size or best quality adhesive complete all as specified and directed by Engineer-in-Charge.
56M&L for Complete removal of existing treatment from walls, fins, chajja etc shall include brooming down or steel wire brushing, scrubbing down smoke soot, moulds, moss and efflorescence salts and treating oil and greasy spots and removing debris/ malba to low lying area out side of MOD land and applying 3 to 5 mm thick a layer of Birla white water proof wall care putty on scrapped/uneven surfaces to match with the existing surfaces and affixing selected quality/shade or colour textured wall paper with suitable best qualityadhesivecomplete all as specified and directed by Engineer-in-Charge.
57Taking down carefullyaluminium point wiring (light, Socket or power) completeincluding fittings and fixturessuch as switches, ceiling roses pendents, regulators, sockets etc for taking credit to be measured separetly including making good the disturbed portion/surface complete all as specified and directed by Engineer-in-Charge.
58M&L for point wiring with colour coding multistranded copper conductor cable,PVC insulated and (FRLS) unsheathed size 1.5 Sqmm with PVC concealedConduit( dia not les than 25 mm) with fixing accessories for one light /fan/bell point controlled by one switchwith pressed steel concealed terminal boxes coveredwith 3mm thick laminated sheet incl. contineous earth wire of PVC insulated unsheathed multi stranded copper conductor cablesize 1.5 Sqmm for earth wire connected to common earth dollycomplete all as specified and directed by Engineer-in-Charge. Make : Havells,Polycab,Finolex and RR Kable.
59All as per item No 58 above but for one3/5 pin socket 5 Amp on same board, with 1.5Sqmm wire with 1.5Sqmm earth wire complete all as specified and directed by Engineer-in-Charge.
60All as per item No 58 above but for one3/5 pin socket 5 Amp on independent board with 1.5Sqmmwire with 1.5Sqmm earth wire complete all as specified and directed by Engineer-in-Charge.
61All as per item No 58 above but for 3 pins socket outlet 15 Amps independent with 4.0 sq mm incl contineous earthing with multistandred copper conductor PVC insulated unsheathed size 4.0 Sq mm complete all as specified and directed by Engineer-in-Charge. Note:-(For item 58 to 61) Cost making good disturbed surface below existing point wiring taken out vide item No 02 and cutting chases and making good of disturbed surfaces by cement & sand mortar (1:3) and surface finish as per adjustment surface conduit and all accessories as required for concealed point wiring vide item No 58 to 61 as applicable shall be deemed to be included in the unit rate quoted against these items.
62M&L for point wiring with multistranded copper conductor cable,PVC insulated and unsheathedsize 1.5 Sqmm (FRLSH) drawn in and inclPVC casing and caping with fixing accessories for one light /fan point controlled by one switchwith pressed steel concealed terminal boxes coveredwith 3 mm thick laminated sheet incl continous earth wire of PVC insulated unsheathed multi stranded copper conductor cablesize 1.5 Sqmm for earth wire connected to common earth dollycomplete all as specified and directed by Engineer-in-Charge. Make : Havells,Polycab,Finolex and RR Kable.
63All as per item No 62 above but for one3/5 pin socket 5 Amp on same board.with 1.5 Sqmm wire with 1.5Sqmm earth wire complete all as specified and directed by Engineer-in-Charge.
64All as per item No 62 above but for one3/5 pin socket 5 Amp on independentboard.with 1.5 Sqmm wire with 1.5Sqmm earth wire complete all as specified and directed by Engineer-in-Charge.
65All as per item No 62 above but for 3/5 pins socket outlet 15 Amps independent with 4.0 Sqmm incl continous earthing with multistandred copper conductor PVC insulated unsheathed size 4.0 Sqmm complete all as specified and directed by Engineer-in-Charge.
66S&F switch piano flush type/Bell push, 5 Amps, single pole one way 230 Volts , AC complete all as specified and directed by Engineer-in-Charge. Make : Anchor, Cona , Havells, Polycab
67S&Fsocket 3/ 5 pins, 6 Amp, flush type piano (multi purpose) 230 Volts , AC complete all as specified and directed by Engineer-in-Charge. Make : Anchor, Cona , Havells, Polycab
68S&F Socket 15 Amps flush type,3/ 6 Pin, 230 Volts , AC complete all as specified and directed by Engineer-in-Charge. Make : Anchor, Cona , Havells, Polycab
69S&F switch15 Amps flush type 230 Volts , AC complete all as specified and directed by Engineer-in-Charge. Make : Anchor, Cona , Havells, Polycab
70S&F Modular switchflush type, 5/6 Amps, single pole one modulewhite colour 230 Volts , AC complete all as specified and directed by Engineer-in-Charge. Make : Crabtree, Havells ,C&S,Legrand
71S&F Modular switch flush type, 15/16 Amps, single pole one module white colour 230 Volts , AC complete all as specified and directed by Engr-in-Charge. Make : Crabtree, Havells ,C&S,Legrand
72S&F Modular socket3 pins combined, 5/6 Amp, flush type(multi purpose)two module ,230 Volts , AC complete all as specified and directed by Engineer-in-Charge. Make : Crabtree, Havells ,C&S,Legrand
73S&F Modular socket5 /6 pins combined, 15A/16 Amp, flush type(multi purpose)two module 230 Volts , AC complete all as specified and directed by Engineer-in-Charge. Make : Crabtree, Havells ,C&S,Legrand
74S&F Modular white cover plate with frame suitable for three module way 230 Volts , AC complete all as specified and directed by Engineer-in-Charge. Make : Crabtree, Havells ,C&S,Legrand
75S&F Modular white cover plate with frame suitable for four module way 230 Volts , AC complete all as specified and directed by Engineer-in-Charge. Make : Crabtree, Havells ,C&S,Legrand
76S&F Modular white cover plate with frame suitable for six module way 230 Volts , AC complete all as specified and directed by Engineer-in-Charge. Make : Crabtree, Havells ,C&S,Legrand
77S&F Ding Dong door bell230 Volts , AC complete all as specified and directed by Engineer-in-Charge. Make : Anchor, Cona , Havells, Polycab
78S&F Bell push flush type 5 Amps, single pole one way 230 Volts , AC complete all as specified and directed by Engineer-in-Charge. Make : Anchor, Cona , Havells, Polycab
79S&F Modular Bell push flush type 5 Amps, single pole one way 230 Volts , AC complete all as specified and directed by Engineer-in-Charge. Make : Crabtree, Havells ,C&S,Legrand
80S&F ceiling rose, PVC / Polycarbonate isolated body ,surface backlite, 65x50mm,three terminals, 230 Volts , AC complete all as specified and directed by Engineer-in-Charge. Make : Anchor, Cona , Havells, Polycab
81S&F modular stepped type electronic fan regulator flush type,2-way 230 Volts , AC complete all as specified and directed by Engineer-in-Charge. Make : Crabtree, Havells ,C&S,Legrand
82S&F stepped type electronic fan regulator flush type 230 Volts , AC complete all as specified and directed by Engineer-in-Charge. Make : Anchor, Cona , Havells, Polycab
83S&FBatten holder PVC/Polycarbonate base / backsuitable for LED lamp. 230 Volts , AC complete all as specified and directed by Engineer-in-Charge. Make : Anchor, Cona , Havells, Polycab
84S&F LED Bulbs 9/10W B-22 Pin type 230 Volts , AC completeall as specified and directed by Engineer-in-Charge. Make : Crompton, Bajaj, Polycab , Wipro
85S& FPVC Combination Box type complete with switch & socket 5/6 Amp ,230 Volts , AC completeall as specified and directed by Engineer-in-Charge. Make : Anchor, Cona , Havells, Polycab
86S& FPVC Combination Box type complete with switch & socket15/16 Amp.230 Volts , AC completeall as specified and directed by Engineer-in-Charge. Make : Anchor, Cona , Havells, Polycab
87S& F plug top of 16 Amp, 3 Pin 230 Volts , AC completeall as specified and directed by Engineer-in-Charge.Make : Anchor, Cona , Havells, Polycab
88S& F plug top of 05 Amp, 3 Pin 230 Volts , AC completeall as specified and directed by Engineer-in-Charge.Make : Anchor, Cona , Havells, Polycab
89S& F AC plug to of 20 Amp, 3 Pin suitable for AC Box (sheet metal enclosure with a two pin and earth plug and socket ) 230 Volts , AC completeall as specified and directed by Engineer-in-Charge. Make :Legrand , L&T , Havells ,Schneider,Anchor
90S& F AC socket of 20 Amp, 3 Pinsuitable for AC Box (sheet metal enclosure with a two pin and earth plug and socket ) 230 Volts , AC completeall as specified and directed by Engineer-in-Charge. Make :Legrand , L&T , Havells ,Schneider ,Anchor
91S&F single pole and neutralsheet metal enclosure with a two pin and earth plug and socket complete with one single pole 20 ampsMCB complete all as spec ified and directed by Engineer-in-Charge. Make :Legrand , L&T , Havells ,Schneider,Anchor
92S&F Skylite recess mounting,36W, LED 2"x2" luminaire integrated electronic driver, optics diffused, completeincluding electrical connection with copper cable from ceiling rose to fittings andtaking down old Unserviceable light fittings of any type and any sizecomplete all as specified and directed by Engineer-in-Charge.
93S&F LED tube light fittings 20W (4 feet) wall mounted LED batten extruded PVC heat sink provided for efficient heat dissipation & integrated electronic driver optics diffused complete including electrical connection with copper cable from ceiling rose to fittings and including taking down existing fittings all as directed by Engineer-in-Charge. Make : Crompton , Havells, Polycab , Bajaj , Philips
94S&FLED 6000K (2’ feet), 10WDecorativeLED lighting fixture with extruded PVC . heat sink, environmental friendly, energy efficient ready to use pack, complete and including taking down existing fittings all as directed by Engineer-in-Charge. Make : Crompton , Havells, Polycab , Bajaj , Philips
95S&F LED bulkhead luminaire 10W decorative type as per sample completeincluding electrical connection with copper cable from ceiling rose to fittings and including taking down existing fittings all as directed by Engineer-in-Charge. Make : Crompton , Havells, Polycab , Bajaj , Philips
96S&F LED building secuity light 25 watt made up of pressure die cast aluminium housing with mid power LED as lightening source and PC cover having top opening inbuilt LED driver with IP66 protection and impact resistance of IK-07 complete including GI bracket with nut bolts, washers etc includingelectrical connection with copper cable from ceiling rose to fittings and including taking down existing fittings all as directed by Engineer-in-Charge. Make : Crompton , Havells, Polycab , Bajaj , Philips
97M&L for submain wiring with 2X6.0 SqmM+1X6.0SqmM Earth Wire single core PVC insulatedFRLSH sheathed copper cableconnecting to common earth dolly in and including heavy dutyPVC casing caping and dismantling and taking down existing unserviceable wiring, all accessories complete all as specified and directed by Engineer-in-Charge.
98M&L for submain wiring with 2X6.0 SqmM+1X6.0SqmM Earth Wire single core PVC insulatedFRLS sheathed copper cableconnecting to common earth dolly in and including heavy duty PVC concealedConduitand dismantling and taking down existing unserviceable wiring, all accessories complete all as specified and directed by Engineer-in-Charge. Note:- Cost making good disturbed surface below existing point wiring taken out vide item No 97 and cutting chases and making good of disturbed surfaces by cement & sand mortar (1:3) and surface finish as per adjustment surface conduit and all accessories as required for concealed point wiring vide item No 97 to 98 as applicable shall be deemed to be included in the unit rate quoted against these items.Make : Havells,Polycab,Finolex and RR Kable.
99S&F in repairs VTPN 4 way double door prewired distribution board TPN-DPX 125 MCCB including one No MCCB 125 Amps, 25 kA, 4 pole as incomer and suitable SPN/TP MCBs as outgoing double door type sheet metal enclosure 415V with 200 Amps rated standard busbar of suitable size plate and common neutral link without MCBs with blank plate suitable for 4 way complete and including taking down VTPN DB"s all as specified and all as directed by Engineer-in-Charge. Make : Havells , Legrand , L&T , Seimens,Indo Asian Note : Rates of MCCB and MCB SPN/SP/TP shall deemed to be included in the quoted rates.
100S&F in repairs Distribution board 4 way TP&NDouble Door are fitted with Bus Bars, Neutral Links suitable for415V, 50Hz, Blanking Plates, Suitable for TP/FP MCB complete all as specified and directed by Engineer-in-Charge. Make : Havells , Legrand , L&T , Seimens,Indo Asian
101S & Fin repairs single pole and neutral sheet metal enclosures for Distribution board (DB"s)suitable for MCBs fitted with busbar , Neutral link ,Earth Bar and Din rail 240 V, 50 Hz supply double door SP&N DB system 12 ways complete all as specified and directed by Engineer-in-Charge. Make : Make : Havells , Legrand , L&T , Seimens, Indoasian
102All as per item No 101 above but 8 ways complete all as specified and directed by Engineer-in-Charge.
103All as per item No 101 above but 4 ways complete all as specified and directed by Engineer-in-Charge.
104S&F MCB TPN 63 to 100 AMPS Amps 415Vincl all termnials, fitting etc including taking down complete all as specified and directed by Engineer-in-Charge. Make : Havells , Legrand , L&T ,seimens, Schneider , Indo Asian
105S&F RCBOs for earth leakage,over load & short circuit protection2 pole ,25 Amp rating, 300 mA capacity suitablefor 240 Volts and including taking down existing MCB/ RCCB complete all as specified and directed by Engineer-in-Charge. Make : Havells , Legrand , L&T ,seimens, Schneider , Indo Asian,Hager
106S&F MCB SPN 40-63 Amps 240Vincl all termnials, fitting etc. including taking down complete all as specified and directed by Engineer-in-Charge. Make : Havells , Legrand , L&T ,seimens, Schneider,Indo Asian
107S&F MCB SP 06 to 40 Amps 240Vincl all termnials, fitting etc including taking down complete all as specified and directed by Engineer-in-Charge. Make : Havells , Legrand , L&T ,seimens, Schneider , Indo Asian
108M&L for rewinding of exhaust fan of size 250 to 600 mm sweep Including Taking down ,dismantiling, opening ,descaling, adjustment, re fixing , cleaning, greasing, painting, replacing minor spares (ie nut, bolt,washers) and rewinding with proper size enamelled copper wire warnishing (spares mentioned below will be measured and paid separatelly) complete all as specified and directed by Engineer-in-Charge.
109All as per item No 108 above Ball bearing complete all as specified and directed by Engineer-in-Charge.
110All as per item No 108 above Brass bushes complete all as specified and directed by Engineer-in-Charge.
111All as per item No 108 above Exhaust fan louvers complete with nut & bolts etc complete all as specified and directed by Engineer-in-Charge.
112All as per item No 108 above Exhaust fan blade of any sweep with screws/bolts, nuts complete all as specified and directed by Engineer-in-Charge.
113M&L for servicing,Taking down Ceiling fan , Air circulator & wall mounted fans any size and any sweep removing cleaning of dust, properly cleaning greasing of bearing including replacing andconnecting up complete all as specified and directed by Engineer-in-Charge.
114M&L for rewinding of Ceiling fan , Air circulator & wall mounted fans of any size any sweep and any capacity of fansusing super enameled copper conductor of suitable gauge including insulation varnishing, packing including taking down and refixing the fans in original position complete all as specified and directed by Engineer-in-Charge.(Note: spares mentioned below will be measured and paid separatelly)
115All as per item No 114 above Ball bearing complete all as specified and directed by Engineer-in-Charge.
116All as per item No 114 abbove Brass bushes complete all as specified and directed by Engineer-in-Charge.
117All asper iem No 114 above 2.5 to 4.0mfd capacitor complete all as specified and directed by Engineer-in-Charge.
118Taking down Geyser of any size and capacity after disconnecting all electrical and water connections, dismantling of geyser for checking of unserviceable parts, repair/replacement ofworn out parts, reassembling, testing, cleanig with chemical to clear choking due to scaling and refixing in its original location incl making all necessary electrical & water connections complete all as specified and directed by Engineer-in-Charge. (Note: Parts will be measured separately and paid for under ‘Supplied only’ rates here-in-after)
119S&F in Repairs Geyser Element Tringular type 1.5 KW complete all as specified and directed by Engineer-in-Charge. Make: ISI Marked
120S&F in Repairs Geyser thermostate for1.5 KW complete all as specified and directed by Engineer-in-Charge. Make: ISI Marked
121M & L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level),and top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanisedmeans of earth wire 4 mm dia with bolts, nuts & check nuts, and washers of galvanised iron protection pipe light grade of 15 mm dia and watering pipe medium grade of 20 mm dia and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC 1:3:6 type C-2 all as shown in electrical plate No-3 of SSR part-I of 2009 connected to earthing test point all as specified and indicated including all earth work excavation, returning filling and disposal of surplus soil and testing on completion complete all as specified and directed by Engineer-in-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail