Tender For Repair / Maintenance Of Summer Appliances, Split Ac, Window Ac, Ductable Type Ac, Cassette Type Ac And Other E/ M Works, sulur-Tamil Nadu

Military Engineer Services-MES has published Tender For Repair / Maintenance Of Summer Appliances, Split Ac, Window Ac, Ductable Type Ac, Cassette Type Ac And Other E/ M Works. Submission Date for this Tender is 20-05-2023. Air Conditioner Tenders in sulur Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

37451837
Corrigendum : Tender For Repair / Maintenance Of Summer Appliances, Split Ac, Window Ac, Ductable Type Ac, Cassette Type Ac And Other E/ M Works
Open Tender
Indian
Tamil Nadu
sulur
20-05-2023

Tender Details

Repair / Maintenance Of Summer Appliances, Split Ac, Window Ac, Ductable Type Ac, Cassette Type Ac And Other E / M Works Repair / Maintenance Of Summer Appliances, Split Ac, Window Ac, Ductable Type Ac, Cassette Type Ac And Other E / M Works At Af Stn Sulur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-May-2023 AMENDMENT Financial Bid 20-05-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 99000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR / MAINT OF SUMMER APPLIANCES, SPLIT AC, WINDOW AC, DUCTABLE TYPE AC, CASSETTE TYPE AC AND OTHER E& M WORKS AT AF STN SULUR
Sl. No. Item Description
1SCHEDULE A BOQ
2M&L for shifting of Air Conditioner, window/Split type capacity up to 2 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed by Engineer-in-Charge.
3Note for Item No 2 :- The rate for following works deemed to be included in quoted rate :- (a)Transportation of air conditioner any type any capacity from one to other location.
4(b) Fixing only base plate with necessary fixing material on stone / brick walls and as directed
5(c) Fixing only outdoor and indoor units as required and directed
6(d) Connecting indoor / outdoors units of split ACs with copper tubes, flairs nuts, warping suction and discharge lines with inclucating materials with necessary fixing arrangements such as bolts, nuts washers and clamps etc on walls.
7(e) fixing PVC pipes 50mm dia for outlet of outdoor units to drain out dew water with necessary clamps.
8(f) Fixing of wall mounting voltage stabilizer of 3 KVA to 5 KVA capacity on the wall with necessary fixing arrangements such as bolts, nuts washers and clamps etc on wall.
9(g) Fixing PVC hose/ PVC pipes of 15mm sizes as reqd at site with necessary junction boxes, PVC bends etc. including two length of PVC copper cables of 4 sqmm size for electrical connection of ACs.
10Supply and fix flair nut of dia 5/8", 1/2", 3/8", 1/4", 1/16" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed
11M & L for pressure testing and rectifying the leakages found in the system of window/ split type ACs capacity up to 2 Ton capacity including vacumizing, charging and checking the gas pressure to desire level complete for satisfactory functioning complete all as specified and as directed. Note:Toping up of gas will be measured and paid seperately
12S&F Hermetic sealed/Rotory new compressor for window type ACof capacity 1.5 Ton including disconnecting the electrical and refrigerant connection of defective sealed unit ofwindow type ACof capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and as directed.
13Note for Item No 12 :- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
14Supply and fixing front grill suitable for window type Air Conditioner of any make up to 1.5 TR capacity, including taking down existing one complete all as specified and as directed.
15Supply and fixing Selector switch, suitable for window type Air Conditioner of any make up to 1.5 TR capacity, including taking down existing one complete all as specified and as directed.
16Supply and fix condenser fan blade suitable for 1 Ton / 1.5 Ton split/ window AC including taking down existing unserviceable one complete all as specified and as directed.
17Supply and fixing Thermostat suitable for window type Air Conditioner of any make up to 1.5 TR capacity, including taking down existing one complete all as specified and as directed.
18Supply and fixing Over load relaysuitable for window type Air Conditioner of any make up to and including 1.5/ 2 TR capacity, including taking down existing one complete all as specified and as directed.
19Supply and fixing Blower motor suitable for window type Air Conditioner of any make up to 1.5/ 2 TR capacity including taking down existing unserviceable one complete all as specified and as directed.
20S & F Condenser coil after disconnecting the refrigerant connection of defective condenser coil unit of window type ACupto and including 1.5/ 2 Tonand replacing the condenser coil unit connectingthe same unit withrefrigerant connections complete including taking down existing one complete all as specified and as directed.
21Supply and fix overload protector for window/ split AC 1.5/2 Ton TR capacity including taking down existing unserviceable one complete all as specified and as directed. Make: Indfoss or equivalent
22Comprehensive Repair & servicing of2 KVA to 7.5KVA on line UPSof Make BEC with battery with distilled water, attending day to day complaints complete all as specified and as directed by the Engineer -in-charge. Location - 28 runway end, Navy hangar, HRDF hut.
23Comprehensive Repair & servicing of5 KVAsingle phase on line UPSof Make Aplab with battery ,attending day to day complaints complete all as specified and as directed by the Engineer -in-charge. Location - New TRCD Bldg (06 Nos), Old TRCD Bldg-04 Nos, New ATC (RT Cabin/ Met Section) - 04 Nos, Transmitter - 01 No.
24Comprehensive maintenance of 25KVA true online UPS system with SMF batteries, with input supply of 3 phase 415V,50HZof Make Aplab including attending day to day complaints , isolating UPS from system, Opening up, examining the accessories parts, cleaning, soldering as required and testing and connecting back with the system complete all as specified and as directed by the Engineer -in-charge, once in 03 months. Location :- CRRW.
25Comprehensive maintenance of 40KVA true online UPS system with SMF batteries,with input supply of 3 phase 415V,50HZ of Make Aplab including attending day to day complaints , isolating UPS from system,Opening up,examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system complete all as specified and as directed by the Engineer -in-charge. Location generator set room.
26Note for Item No 22 to 25 :- (a) The contractor shall make AMC contract with the original manufacturer ofequipment and the repairs/maintenance shall be carriedout through the original manufacturers only.
27(b) Cost of any minor items to be replaced is included in the item rate quoted. Whereas major items shall be measured and paid under supply only items here-in-after, however the labour element for taking down old unserviceable items and fixing the new one shall be deemed to be inclusive under the comprehensive maintenance
28(c) Payment shall be made thrice for the period of 11 months proportionately.
29Supply only Cooling fan suitable for 5 to25KVAtrue online UPSof existing Make - Aplab complete all as specified and as directed.
30Supply only DC Capacitor suitable for 5 to50KVA true online UPSof existing Make - Aplabcomplete all as specified and as directed.
31Supply only IGBT suitable for 5-25KVA true online UPSof existing Make - Aplab complete all as specified and as directed.
32Supply only IGBT suitable for 40-50KVA true online UPS of existing Make - Aplab complete all as specified and as directed.
33S & F hermetic sealed/Rotory new compressor for split type AC upto and including 1.5 TR capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of split type ACof capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and as directed.
34Note for Item No 33 :- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
35S & F Condenser coil after disconnecting the refrigerant connection of defective condenser coil unit of split type ACupto 1.5 TRand replacing the condenser coil unit connectingthe same unit withrefrigerant connections complete including taking down existing one complete all as specified and as directed.
36Supply and fixing in repair flexible PVC pipe of suitable size for indoor unit drain water of split AC suitable for any type and any capacity complete complete all as specified and as directed.
37M&L for Refrigerant gas, (R 407C/R410) suitable for cooling equipments supplied and filled complete all as specified and as directed.
38Supply and fix 3 pin metal clad plug top 20 Amps, AC 230 volts for any type of AC including taking down existing unserviceable one complete all as specified and as directed.
39Supply & fix in repair metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls complete all as specified and as directed. Make : Cat Pt No 607841 of Legrand or equivalent of Schnieder (Multi -9) or Siemens/L&T (Hegar).
40Supply and fix in repair dummy nut of dia 3/8" , 1/4" , 5/8" ,1/2" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed
41S & F PVCinsulated multi stranded copper conductor 3 core 2.5 sq.mm, including connecting up and taking down existing unserviceable cable of any description and size complete all as specified and as directed.
42Comprehensive maintenance of Dehumidifier 230 volts single phase, 50 Hz, Model- FFB-170 Make : Bry Air including checking of airflow line, setting of safety valves, vibration and abnormal noise check, cleaning of air filters, checking functioning of valves by the original manufacturer complete all as specified and directed. Location – SRE, SES Bldg.-2 Nos
43Note for Item No 42 :- (a) The contractor shall make AMC contract with the original manufacturer ofequipment and the repairs/maintenance shall be carriedout through the original manufacturers only.
44(b) Cost of any minor items to be replaced is included in the item rate quoted.
45(c) Payment shall be made thrice for the period of 11 months proportionately.
46M & L disconnecting electric connection from defective blower/ fanmotor and taking out from unit capacity 8.75TR of existing make and transporting to workshop after getting the gate pass from Engineer-in-Charge. Dismantling the burntwinding & rewinding of 1/6 to 1/8 HP double shaft blower motor with the existing size of super enemelled copper winding wire as per maunufactrer instructions including insulation, varnishing, greasing, testing complete and transporting back to the location from where it was disconnected and refixing the same and testing complete all as specified and as directed.
47Supply and fixing in repair of Outdoor fan motor suitable for small shaft condensing coil including blade suitable for ductable AC of 8.75TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
48Supply and fixing liquid line drier filter suitable for 8.75 ton ductable AC with necessary brazing work and charging the refrigerant after replacing the liquid line filter to obtain adequate cooling complete including taking down existing one complete all as specified and as directed. Note :Supply and charging refrigerent gas will be measured and paid seperately under relavent items. Make of drier filter: LG / Danfoss / Hitech
49Inspection, checking adjustment and minor repair of unserviceable window type/ split type AC any type any capacity placed at any location includes repair/ replacement of defective parts such as checking of electrical connection, condenser, gas leakage, PCB, condenser fan blade, indoor unit, outdoor unit, compressor, PVC pipe etc, complete all as specified and as directed by Engineer-in-Charge. Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed by Engineer-in-Charge.
50Supply and fix in repair single phase single pole contactor suitable for 1.5/ 2.0 split type AC complete all as specified and as directed.
51Repair and maintenance of inverter type splitAC of any capacity / any Make from any location including attending breakdown calls, routine maintenance and servicing ,testing and commissioning complete all as specified and as directed. here under :-
52a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower.
53b) Checking electrical connection, cleaning, Greasing, oiling, fan motor, cleaning of air filter with blower.
54(c) Testing all copper tube ,joints, leads for any leaking and Top up with the refrigerant gas if necessary.
55(d)The work shall be done by a specialized team of Engineer/Technicians of OEM.
56(e)Nearly 50 number of inverter type split AC are installed at the distant height. To carryout servicing of these AC"s special T&P (Boomer vehicle) of height 24 meter will be required. The cost of arrangement of special T&P will be inclusive in quoted rate.
57S&F PCB board of inverter type split type ACfor 1.5 Ton/2 Ton including taking down existing unserviceable one at any location complete all as specified and as directed.
58M&L for dismantling the transformer from the stabilizers of 4 KVA and removing the old / burnt transformer and replaced with new transformer complete all as specified and as directed.
59M&L for dismantling the transformer from the stabilizers of 5 KVA and removing the old / burnt transformer and replaced with new transformer complete all as specified and as directed.
60S & F in repair of following spare parts for 4 KVA to 5 KVA capacity stabilizers complete all as specified and as directed.
61(a) Relay set ( set of two )
62(b) PCB ( Printed circuit board)
63S&F in repair Digital voltmeter 0-250volt for voltage stabilizers any type as per existing complete all as specified and as directed.
64Taking down and strip opening of old unserviceable sealed unit compressor of any make from cassette type air conditioner by disconnecting cooling and condensor copper pipe and electric connection carefully and S&F new scroll compressor of capacity 4 ton including charging of refrigerant gas R-22/ R-407C upto required cooling and connecting all the copper pipes, electric connection and testing the AC complete all as specified and as directed. Note :Supply and charging refrigerent gas will be measured and paid seperately under relavent items
65Taking down of defective evaporator unit of 4TR capacity Cassette type AC and supply & fixing new evaporator unit of the same capacity (Make: Toshiba/ LG/ Totaline or equivalent) with blower motor, front grill and connecting the copper tubing by brazing, detecting leakage, rectifying the same and recharging with refrigerant gas as required to obtain adequate cooling complete all as specified and as directed. Note: Supply & charging of refrigerant gas will be measured and paid for separately
66S&F condensing unit of Cassettetype AC of capacity 4 TR capacity condensing/ outdoor unit complete with condensing coil, coil frame, wiring kit, starting and running capacitor, relay, condensing/ outdoor motor with blade complete including taking down existing one complete all as specified and as directed. Make: Toshiba/ LG/ Voltas or equivlent) Note : Supply and charging of refrigerent gas will be measured and paid for separetly.
67S & F liquid line drier filter suitable for 4 TR cassette type AC with necessary brazing work and charging the refrigerant after replacing the liquid line filter to obtain adequate cooling complete including taking down existing one complete all as specified and as directed. Note :Supply and charging refrigerent gas will be measured and paid seperately under relavent items. Make of drier filter: LG / Danfoss / Hitech
68S & F outdoor fan motor suitable for small shaft condensing coilincluding blade suitable for cassettte AC of 4 TR complete including taking down existing one complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar
69S & F thermal relay 15A, 230 Volt, single phase suitable forcassette type AC of 4 TR capacitycomplete including taking down existing one complete all as specified and as directed. Make : LG /Hitech/Indo Asian/ L&T/ Tecumseh.
70M & L for carrying out pressure leak test of 4 ton cassette type AC whenever required by nitrogen gas pressure for detecting leakage in cooling/condensing unit refrigerant pipe and repairing the leakage by welding or brazing of condensing/ cooling unit, refrigerant pipe and putting under pressure for leakage checking after repair of leaking pipe flushing out by N2 and CTC/ vaccumization complete all as specified and as directed. Note :- Supply & charging of refrigerant gas R-22/R-407C will be measured and paid for separately
71S & F multi capacitors 36 µfd for cooling appliances and including taking down existing one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL
72S & F multi capacitors 50+2 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL
73S&F in repairs on distribution board MCCB four pole, 125 Amp ultimate breaking capacity 25 KA, 415V including connecting by using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified and as directed. Make : L & T/ Siemens/ ABB
74S&F in repairs on distribution board MCCB three pole, 63 Amp ultimate breaking capacity 16 KA, 415Vincluding connecting by using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified and as directed. Make :L & T/ Siemens/ Legrand
75Supply and fix in repair Double pole MCB 32 Amp, 240 V, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and as directed. Make : Siemens/ ABB/ Legrand.
76PVC tape roll self adhesive of size 1.90cm x 0.125mm x 25m. complete all as specified and as directed. Make- Steelgrip, Kinjal, Anchor.
77M&L for Sub main wiring with PVC insulated unsheathedFRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and as directed.
78Note for item No 77: (a)2 runs of 4 sqmm cable along with onerun of 4 sqmm cable for earth conductor alongwith PVC conduit shall be measured as one length. (b)Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
79M & L carrying out pressure leak test of 8.75 ton ductable split type AC whenever required by nitrogen gas pressure for detecting leakage in cooling/condensing unit refrigerant pipe and repairing the leakage by welding or brazing of condensing/ cooling unit, refrigerant pipe and putting under pressure for leakage checking after repair of leaking pipe flushing out by N2 and CTC/ vaccumization complete all as specified and as directed. Note :- Supply & charging of refrigerant gas R-22/R-407C will be measured and paid for separately
80Supply and fixing in repair of Indoor blower motor for cooling coil including blower suitable for ductable AC 8.75 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
81Supply and fixing Air filter set suitable for 8.75 ton ductable split type AC complete including taking down existing one all as specified and as directed. Make : LG / Danfoss / Hitech
82Supply and fixing PCB (circuit plate) of in-door unit of 8.75 TR ductable split AC complete including taking down existing complete all as specified and as directed.
83Taking out ofdefective wiring of indoor/ outdoor unit ofPCB, visual eye damp plates,Supply and fixing new wiring in place of damaged items of capacity of AC 8.75 TR including matching the existing system complete all as specified and as directed.
84Supply and fixing in repair of Complete wiring kit for outdoor panel of ductable AC of capacity 8.75Ton complete all as specified and as directed.
85Supply and fixing Reverse cycle valve suitable for cassette type AC of capacity 8.75 Ton complete including taking down existing one complete all as specified and as directed.
86Supply and fixing Low pressure switch for 8.75 ton ductable split type AC complete including taking down existing one complete all as specified and as directed. Make : LG / Danfoss / Hitech
87Supply and fixing in repair Wall mount remote kit with wire and complete assembly suitable for ductable AC of 8.75 TR complete all as specified and as directed.
88Supply and fixing Thermal relay 20A, 415 Volt, single phase suitable forductable split type AC of 8.75 TR capacity complete including taking down existing one all as specified and as directed. Make : LG / Tecumseh / Hitech/ Indo Asian/L&T.
89Supply and fixing Single phase preventor, 230 volt, 50 HZ, AC supply complete including taking down existing one complete all as specified and as directed. Make : L&T / Seimens / BCH
90Supply and fixing AC 4 Pole power contactor three phase of capacity 40 Amp suitable for LG 8.75 TR capacity ductable split type AC complete including taking down existing one complete all as specified and as directed.
91S & F insulation on and around suction and discharge copper tube of size 3/8"/ 5/8" with 6mm thick flexible thermocol heat resistance duly wrapped with sticking tape and finally covered with flexible PVC conduit of 50mm bore complete including taking down existing damaged one complete all as specified and as directed.
92Taking down of defective evaporator unit of 2TR capacity Cassette type AC and supply & fixing new evaporator unit of the same capacity suitable for existing AC(Make: Toshiba/ LG/ Totaline or equivalent) with blower motor, front grill and connecting the copper tubing by brazing, detecting leakage, rectifying the same and recharging with refrigerant gas as required to obtain adequate cooling complete all as specified and as directed. Note: Supply & charging of refrigerant gas will be measured and paid for separately
93S&F in repairs condensing unit of Cassettetype AC of capacity 2 TR capacity condensing/ outdoor unit complete with condensing coil, coil frame, wiring kit, starting and running capacitor, relay, condensing/ outdoor motor with blade complete all as specified and as directed Make: Toshiba/ LG/ Voltas or equivlent) Note : Supply and charging of refrigerent gas will be measured and paid for separetly.
94M & L for carrying out pressure leak test of 2 ton cassette type AC whenever required by nitrogen gas pressure for detecting leakage in cooling/condensing unit refrigerant pipe and repairing the leakage by welding or brazing of condensing/ cooling unit, refrigerant pipe and putting under pressure for leakage checking after repair of leaking pipe flushing out by N2 and CTC/ vaccumization complete all as specified and as directed. Note :- Supply & charging of refrigerant gas R-22/R-407C will be measured and paid for separately
95S & F in repair Outdoor fan motor suitable for small shaft condensing coilincluding blade suitable for cassette AC of 2 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
96S & F in repair PCB (circuit plate) of in-door unit of 2.0 TR ductable split AC complete all as specified and as directed.
97S & F in repair thermal relay 7.5A, 230 Volt, single phase suitable forcassette type AC of 2 TR capacitycomplete all as specified and as directed. Make : LG /Hitech/Indo Asian/L&T/Tecumseh.
98S & F in repair reverse cycle valve suitable for cassette type AC of capacity 2 Ton complete all as specified and as directed.
99S & F in repair pipe thermister suitable for cassette type AC of capacity 4 Ton complete all as specified and as directed.
100S & F reverse cycle valve suitable for cassette type AC of capacity 4 Ton complete including taking down existing one complete all as specified and as directed.
101S & F PCB (circuit plate) of in-door unit of 4.0 TR ductable split AC complete including taking down existing one complete all as specified and as directed.
102Removing the window/ split type AC upto 1.5/ 2 ton capacity of any make from any location for carrying out servicing complete as and when ordered and installing back at original location, testing and commissioning complete all as specified and as directed. by Engineer-in-Charge. Note :-The rate of following deemed to be included in quoted rate :- a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower b) Checking electrical connection, cleaning, Greasing, oiling, fan/blower motor, cleaning of air filter with blower c) Wrapping suction and discharge pipe with foam insulation and white roll ,changing drainage pipe when necessary d)The unit rate quoted by the tenderer inclusive for Removing, servicing,installation, commissioning and testing of all equipment’s, materials & labour, tools and plants, and back in on final position complete (e) The work shall be done by a specialized team of Engineer/Technicians of OEM.
103Supply and fixing filter suitable for split type Air Conditioner of any make upto 2 TR capacity, including taking down existing one complete all as specified and as directed.
104Supply and fix discharge valve suitable for 1.5 Ton/2 Ton of split type AC including taking down existing one complete all as specified and directed
105S & F DC blower fan motor for inverter split AC of 1.5 Ton to 2 Ton and including taking down existing unserviceable one of any capacity and at any location complete all as specified and as directed.
106S & F blower of indoor unit suitable for 1.5 Ton / 2 Ton splitAC including taking down existing unserviceable one at any location complete all as specified and as directed.
107Supply and fixing Remote sensing unit for upto 2.0 TR split type AC including taking down existing unserviceable one complete all as specified and as directed.. Make : As per existing AC at the site.
108S & F in repairs copper tube 15 mm / 18 mm dia, superior quality suitable for refrigeration and suction lines of split ACs, drawn trough pipes/ fixed to walls/ laid on floor or roof complete all as specified and as directed.
109Supply and fix metal frame stand factory made outdoor type to hold outdoor split unit of ACs including taking down existing one complete all as specified and as directed.
110S & F Copper tube, 9 mm bore superior quality suitable for refrigeration and discharge lines of split ACs, drawn trough pipes/ fixed to walls/ laid on floor or roof including taking down existing one complete all as specified and as directed.
111S & F filter suitable for window type Air Conditioner of any make up to 1.5/ 2 TR capacity including taking down existing one complete all as specified and as directed.
112Supply and fixing Front grill suitable for split type Air Conditioner of any make up to 2 TR capacity, including taking down existing one complete all as specified and as directed.
113S&F Hermetic sealed/Rotory new compressor for 2 TR split type AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit ofsplit type ACof capacity 2 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and as directed.
114Note for Item No 113 :- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
115S & F Condenser coil after disconnecting the refrigerant connection of defective condenser coil unit of split type ACupto 2.0 TRand replacing the condenser coil unit connectingthe same unit withrefrigerant connections complete including taking down existing one complete all as specified and as directed.
116S & F Filter suitable for window type Air Conditioner of any make up to 1.5/ 2 TR capacity including taking down existing one complete all as specified and as directed.
117S & F over load relaysuitable for split type Air Conditioner of any make up to 2.0 TR capacity, including taking down existing one complete all as specified and as directed.
118S & F remote assembly corded/cordless for any type and size of split type ACs, upto 2.0 TRincluding taking down existing one complete all as specified and as directed.
119Supply and fixing Blower motor suitable for split type Air Conditioner of any make up to 2 TR capacity including taking down existing unserviceable one, complete all as specified and as directed.
120Supply and fix PCB board of any make for indoor unit of split AC 1.5 Ton/ 2 Tonincluding taking down existing one complete all as specified and as directed.
121Supply and fixing Condenser Fan motor suitable for window type Air Conditioner of any make up to and including 1.5/2.0 TR capacity,including taking down existing one complete all as specified and as directed.
122S & F in repair suction valve suitable for 1.5 Ton/2 Ton of split type AC of existing make complete all as specified and as directed.
123Supply and fix indoor unit including blower fan , PCB board and all accessaries capacity 1.5/2.0 Ton split type A/C including taking down existing unserviceable one any type complete all as specified and as directed by Engineer-in-charge