Tender For Repair Replacement Of Unsv Lt Underground Cable And Distribution System Capacitor Blanks Apfc Panel Incl Lt Control Panel And Accessories At Phase I And Ii Area Under Ge Narangi, narangi-Assam

Military Engineer Services-MES has published Tender For Repair Replacement Of Unsv Lt Underground Cable And Distribution System Capacitor Blanks Apfc Panel Incl Lt Control Panel And Accessories At Phase I And Ii Area Under Ge Narangi. Submission Date for this Tender is 24-05-2023. Control Panel Tenders in narangi Assam. Bidders can get complete Tender details and download the document.




Tender Notice

37451756
Corrigendum : Tender For Repair Replacement Of Unsv Lt Underground Cable And Distribution System Capacitor Blanks Apfc Panel Incl Lt Control Panel And Accessories At Phase I And Ii Area Under Ge Narangi
Open Tender
Indian
Assam
narangi
24-05-2023

Tender Details

Repair Replacement Of Unsv Lt Underground Cable And Distribution System Capacitor Blanks Apfc Panel Incl Lt Control Panel And Accessories At Phase I And Ii Area Under Ge Narangi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-May-2023 Other Corrigendum Other 17-05-2023
2 17-May-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-05-2023
3 22-May-2023 Other Corrigendum2 Other 24-05-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work: REPAIR / REPLACEMENT OF UNSV LT UNDERGROUND CABLE AND DISTRIBUTION SYSTEM, CAPACITOR BLANKS APFC PANEL INCL LT CONTROL PANEL AND ACCESSORIES AT PHASE I & II AREA UNDER GE NARANGI.
Sl. No. Item Description
1Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable , etc. n.exc 10 Sqm on planand getting out in soft/loose soil complete all as specified and as directed.
2Returning filling in including spreading, levelling watering and well ramming in layers not exc 25 cm thickin soft /loose soil complete all as specified and as directed.
3Removing surplus soil to a distance not exc 50m and depositing at level not exc 1.5m above the starting point complete all as specified and as directed.
4M&L forcutting the faulty/damaged/burnt end portion of the UG cable of cross sectional area 16 sqmm to 35 sqmm 3.5 core and making good end termination with and including suitable size of aluminium thimble/lugs duly crimped with crimping tool and refixing in existing position including insulation tape, nuts, bolts etc. as required in distribution boards/LT panel boards/ Change over switch complete all as specified and as directed. ( Note :Necessary Excavation and earth work shall be measured and paid seperately if reqd.).
5M&L forcutting the faulty/damaged/burnt end portion of the UG cable of cross sectional area 50 sqmm 3.5 core and making good end termination with and including suitable size of aluminium thimble/lugs duly crimped with crimping tool and refixing in existing position including insulation tape, nuts, bolts etc. as required in distribution boards/LT panel boards/ Change over switch complete all as specified and as directed. ( Note :Necessary Excavation and earth work shall be measured and paid seperately if reqd.).
6M&L forcutting the faulty/damaged/burnt end portion of the UG cable of cross sectional area 70 sqmm to 120 sqmm 3.5 core and making good end termination with and including suitable size of aluminium thimble/lugs duly crimped with crimping tool and refixing in existing position including insulation tape, nuts, bolts etc. as required in distribution boards/LT panel boards/ Change over switch complete all as specified and as directed.( Note :Necessary Excavation and earth work shall be measured and paid seperately if reqd.).
7M&L forcutting the faulty/damaged/burnt end portion of the UG cable of cross sectional area 240 sqmm to 300 sqmm 3.5 core and making good end termination with and including suitable size of aluminium thimble/lugs duly crimped with crimping tool and refixing in existing position including insulation tape, nuts, bolts etc. as required in distribution boards/LT panel boards/ Change over switch complete all as specified and as directed.( Note :Necessary Excavation and earth work shall be measured and paid seperately if reqd.).
8Taking out old unserviceable UG cable of any size/ type from trenches / wall / roof etc. for necessary repair/ replacement / re-laying works complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid seperately).
9M&L for relayingold serviceable UG cable of any size/ typealongwith brick protection, sand cushioning etc as obtained from taking up/down old cable here in before intrenches/ wall/ roof etc. after necessary repair/ rerouting if directedcomplete all as specified and as directed.
10M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 185 sqmm 3.5 core laid in trenches /floor or fixed on wall /poleincluding brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
11M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 25 sqmm 3.5 core laid in trenches /floor or fixed on wall /poleincluding brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
12M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 16 sqmm 4 core laid in trenches /floor or fixed on wall /poleincluding brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
13M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 6 sqmm2 core laid in trenches /floor or fixed on wall /poleincluding brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
14Supply and spreading clean dry river sand in cable trenches as in cable cushioning complete all as specified and as directed. (Note: Punnedthickness shall be measured and paid)
15M&L for Sub class ‘B’ old size well burnt brick laid flat in trenches over the cable forprotection of LT cable complete all as specified and as directed.
16M& L for Manual boring under roads / hard standingby required T&P without disturbing the top surface of the road for passingthe cable in GI Pipe 40mm dia complete all as specified and as directed.
17M&L for GI pipe light grade 40mm bore with all fittings laid in trenches or in floors,including taking up/ down old pipecomplete all as speciffied and as directed
18S&F in repair cable jointing kit for LT (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable foraluminium Conductor cableofsize 25-50 Sqmm 3.5 core complete all as specified and as directed.
19S&F in repair cable jointing kit for LT (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable foraluminium Conductor cable of size 70-120 Sqmm 3.5 core complete all as specified and as directed.
20S&F in repair cable jointing kit for LT (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for aluminium Conductor cable of size 150-185 Sqmm 3.5 core complete all as specified and as directed.
21S&F in repair cable jointing kit for LT (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable foraluminium Conductor cableofsize 240-300 Sqmm 3.5 core complete all as specified and as directed.
22M&L for cement concrete 1:4:8 type D-2( using 40 mm graded crushed stone aggregate) as in foundation fillingand mass concrete complete all as specified and as directed.
23M&L for cement concrete 1:3:6 type C-1( using 20 mm graded crushed stone aggregate) as in fillingand mass concrete including necessary form work for coaping to the new/existing steel pole complete all as specified and as directed.
24M&L forerection and fixing of steel tubular swaged pole type 410 SP - 31 (9.00 metres long) confirming to IS- 2713 Part I to III 1980 with and including cast iron base plate, finial taper plug, nuts, bolts and washers etc. fixed in PCC foundationduly painted painted with two coats of Aluminium paint over a coat of red oxide primer including preparation of surface and including dismsntling of old pole of any size and description with foundation, PCC coping etc. complete all as specified and as directed.
25M & L for preparation of old painted surfaces of LT steel tubular pole 9.00 m long, cross arms, bracings, supports, clamps, back plate with nut bolts washersand providing one coat of aluminium paint including numbering and making strips in circular shape of diameter 150 mm black colour letter of hight 50 mm complete all as directed by Engr in Chargeupto1.5 mtr above ground level with alternate layer of white and black paintcomplete all as specified & as directed.
26S &F street light fitting of60 Watt LED made ofpressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protectionand lens embedded PC Cover having top opening seperate driver compartment,should have luminaire efficacy =110 lumens/watt,CRI>70 ,PF > 0.95,CCT=5500,IP66,impact resistance IK 07 ,inbuiltprotection against lightning , over voltage , short circuit and surge/spike protection device upto10 kV complete also tested for 440 Volt for 8 hour Phase to phase without any damageincluding taking down old unserviceable light fittings complete allas specified and as directed. ( NOTE :(i) PVC insulated PVC sheathed, multistranded aluminium or copper conductor cable of size 1.5 sqmmX 3 core from light fitting to Street light feeder (max 2.0 mtr ) deemed to be included in quoted rate. (ii) Manufacturer’s test certificate of LED light fitting in respect to LM 79 and LM 80 shall be submitted by the contractor.)
27S &F street light fitting o f 70 Watt LED made ofpressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protectionand lens embedded PC Cover having top opening seperate driver compartment,should have luminaire efficacy =110 lumens/watt,CRI>70 ,PF > 0.95,CCT=5500,IP66,impact resistance IK 07 ,inbuiltprotection against lightning , over voltage , short circuit and surge/spike protection device upto10 kV complete also tested for 440 Volt for 8 hour Phase to phase without any damageincluding taking down old unserviceable light fittings complete allas specified and as directed. ( NOTE :(i) PVC insulated PVC sheathed, multistranded aluminium or copper conductor cable of size 1.5 sqmmX 3 core from light fitting to Street light feeder (max 2.0 mtr ) deemed to be included in quoted rate. (ii) Manufacturer’s test certificate of LED light fitting in respect to LM 79 and LM 80 shall be submitted by the contractor.)
28Repairs/maintenance of APFC LT Panel board/box upto 100 KVAR capacity including disconnecting all incoming and outgoing connection after taking necessary shut down, cleaning the carbon/rust from bus-bar, re-thimbling with new lugs/thimble of existing size,removing old burn out wiring and re-wiring with new cable of exising size, including replacement of unserviceable parts complete all as specified & directed :- Note :- (i) New spares shall be measured and paid separately under relevants items as supply only. (ii) Cost of unsheathed multistranded copper conductorof size upto 2.5 Sqmm for internal wiring like connection of CTs deemed to be included in quoted rate.(iii) All calibration of meters and APFC controller shall be done by the contractor after fixing in position. (iv) Suitable size of copper/aluminium cable lugs shall be provided by contractor for fixing/jointing the cable in bus bar etc.
29Supply only Switch disconnector-fuse unit of current rating 100 Amp having terminal shrouds on both sides including phase barrier open execution type suitable for DIN fuse-link(4P) complete all as specified as directed.
30Supply only digital 8 step APFC controller of size 96X96 for contractor switching, operating voltage 415V Volts complete all as specified and as directed.
31Supply only 3 Phase, 415 V power contactor of AC3 rating 25 Amp complete all as specified and as directed.
32Supply only 3 Phase, 415 V power contactor of AC3 rating 32Amp complete all as specified and as directed.
33Supply only 3 Phase, 415 V power contactor of AC3 rating 40 Amp complete all as specified and as directed.
34Supply only coil for MNX 25-MNX 40 contactor 240 V AC complete all as specified and as directed.
35Supply onlyMNXcontactor contact kit complete all as specified and as directed.
36Supply only heavy duty cylindrical type capacitor of capacity 5 k VAR, suitable for operating on 440 Volts 3 Phase complete all as specified and as directed.
37Supply only heavy duty cylindrical type capacitor of capacity 10 k VAR, suitable for operating on 440 Volts 3 Phase complete all as specified and as directed
38Supply only heavy duty cylindrical type capacitor of capacity 12.5 k VAR, suitable for operating on 440 Volts 3 Phase complete all as specified and as directed.
39Supply only heavy duty cylindrical type gas filled capacitor of capacity 20 k VAR, suitable for operating on 440 Volts 3 Phase complete all as specified and as directed.
40Supply only heavy duty cylindrical type capacitor of capacity 25 k VAR, suitable for operating on 440 Volts 3 Phase complete all as specified and as directed.
41M&L for Cross arms, bracings, supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps, stay clamps, D clamps nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including painting with twocoats ofaluminiumpaintover a coat of red oxide primer including taking down the old unserviceable cross arms, clamps etccomplete all as specified and as directed.
42M & L for Prunning / trimming the branches of trees if any along overhead line, 3 m on all side below/ above/ sides of overhead line and removing the same upto a distance of 150m, each span not exceeding 45 m complete all as specified and as directed.
43M & L cutting grasses, shrubs/herbs surrounding LT poles, feeder pillar box installations by mechanical or manual T&P, removing the debris at a distance not exceeding 50m and depositing where directed complete all as specified and as directed.
44M & L for Stringing / stretching, including jointing in situ of each span not more than 45 m betweentwo electric poleshaving 4 Nos of ACSR conductors of any size including GI earth continuity wire, with/ withoutguarding wires onelectric poles of any size at different locations all as directed to the extent of permissible sag or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium tapes after stringing complete all as specified and as directed. (Note :- One span measured as 4 Nos wire of LT over head line and 2 Nos of earth wire.)
45M & L for Stringing / stretching, including jointing in situ of each span not more than 45 m betweentwo electric poleshaving 2 Nos of ACSR conductors of any size including GI earth continuity wire, with/ withoutguarding wires onelectric poles of any size at different locations all as ordered to the extent of permissible sag or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium tapes after stringing complete all as specified and as directed. (Note :- One span measured as 2 Nos wire of LT over head line and 1 Nos of earth wire.)
46M&L for stay assembly comprising 14mm dia iron stay bow, stay strand wire of size 7/3.15mm with stay rod of diameter 16mm complete with all accessories as shown in electrical plate no. 1 of SSR part-I 2009 including dismsntling of oldstay assembly of any description with foundation, etc. complete all as specified and as directed.
47M&Lfor loop type insulator, vitreous porcelain, white, brown or green with overall dimension 90mmX140mm, clearence of hole 25.5mm suitable for 1100 Volts complete all as specified and as directed.
48Repairs/maintenance ofLT Panel board/box upto 100 KVAR capacity including disconnecting all incoming and outgoing connection after taking necessary shut down, cleaning the carbon/rust from bus-bar, re-thimbling with new lugs/thimble of existing size,removing old burn out wiring and re-wiring with new cable of exising size, including replacement of unserviceable parts complete all as specified & directed :- Note :- (i) New spares shall be measured and paid separately under relevants items as supply only. (ii) Cost of unsheathed multistranded copper conductorof size upto 2.5 Sqmm for internal wiring like connection of CTs deemed to be included in quoted rate.(iii) All calibration of meters and APFC controller shall be done by the contractor after fixing in position. (iv) Suitable size of copper/aluminium cable lugs shall be provided by contractor for fixing/jointing the cable in bus bar etc.
49Supply only3 phase single function LED Voltmeter flush mounting 96X96 mm of input voltage measurement range 50-520 VAC (P-P), 5 A, accuracy class 1 for LT panel board complete all as specified and directed
50Supply only3 phase single function LED Ammeter flush mounting 96X96 mm , CT secondary site selectable 1A/5A, accuracy class 1 for LT panel board complete all as specified and directed.
51Supply only3 phase VAF+PF digital meter flush mounting 96X96mm of input voltage measurement range 50-520 VAC (P-P)5A, , accuracy class 1 for LT panel board complete all as specified and directed. Make : L&T Cat Part No.WL411021 OOOO or equivalent in Conserve/ Siemens
52Supply onlyindoor type insulated ring type low tension current transformer of ratio 500/5A, accuracy class 1 for LT panel board complete all as specified and directed.
53Supply onlyLED indicator lamp to be mounted on LT panel for R-Y-B phase ( Of colour Red, Yellow, Green) operates on 240V AC for fixing in the existing place in LT panel board complete all as specified and directed.