Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #37451625

Tender For Repair/Maintenance Of External Water Supply Pipe Lines, Control Valves, Pump Motors And Other Connected Works At Karcham And Poari Under Age E/M (We) In Ge 863 Ews And Repair/Maintenance Of External Water Supply Pipelines, Control Valves And Ot

Issued by Statutory Bodies & Commissions/Committees · karcham, Himachal Pradesh
Tender Value
25 Lakhs
Estimated cost
Bid Submission
26 May 2023
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
karcham → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair / Maintenance Of External Water Supply Pipe Lines, Control Valves, Pump Motors And Other Connected Works At Karcham And Poari Under Age E / M ( We ) In Ge 863 Ews And Repair / Maintenance Of External Water Supply Pipelines, Control Valves And Other Connected Works At Poohunder Age E / M ( We ) In Ge 863 Ews.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 09-May-2023 amendments to BOQ BOQ 19-May-2023
2 19-May-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-May-2023

BOQ

Name of Work : REPAIR/MAINTENANCE OF EXTERNAL WATER SUPPLY PIPE LINES, CONTROL VALVES, PUMP MOTORS AND OTHER CONNECTED WORKS AT KARCHAM AND POARI UNDER AGE E/M (WE) IN GE 863 EWS AND REPAIR/MAINTENANCE OF EXTERNAL WATER SUPPLY PIPELINES, CONTROL VALVES AND OTHER CONNECTED WORKS AT POOHUNDER AGE E/M (WE)IN GE 863 EWS.
Sl. No. Item Description
1Taking down old unserviceable damaged CI/DI pipe of 100 mm size from excavated trenches or from wall/floor including removing of fittings and removal to store or stack asidecomplete all as specified and directed.
2Taking down old unserviceable damaged GI pipe of 80 mm size from excavated trenches or from wall/floor including removing of fittings and removal to store or stack asidecomplete all as specified and directed.
3All as per item serial No 2 here in before but of 50 mm dia.
4All as per item serial No 2 here in before but of 40 mm dia.
5All as per item serial No 2 here in before but of 25 mm dia.
6All as per item serial No 2 here in before but of 20 mm dia.
7All as per item serial No 2 here in before but of 15 mm dia.
8Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m in depth in a hard/dense soil for laying pipes/repair to pipes and sluice/control valves etc. complete all as specified and directed.
9Returning refiling in, including spreading, leveling watering and well raming in layers each not exceeding 25 cm thickness complete all as specified and directed.
10Removing surplus soil to a distance not exceeding 50 mtr and deposting wheredirected at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
11Supply and laying pipe ductile Iron in trenches/floor, Class “K-7” , socket and spigot type, 100 mm dia including suitable titon rubber ringsas required complete all as specified and directed.
12M & L GI tubing medium grade of size 80 mm boreincluding all fitting such as bend, Tee, union, socket etc in trenches complete all as specified and directed.
13All as per item serial No 12 here in before but of 50 mm dia
14All as per item serial No 12 here in before but of 40 mm dia
15All as per item serial No 12 here in before but of 25 mm dia
16All as per item serial No 12 here in before but of 20 mm dia
17All as per item serial No 12 here in before but of 15 mm dia
18M & L in replacement Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \"Y\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs suitable for S/S pipes upto 150 mm dia complete all as specified and directed
19S & F in replacement sluice valve 100 mm dia with stainless steel spindle complete assembly, class PN 1.6, ISI marked including providing rubber gaskets, nut & bolts, washers, etc complete all as specified and directed
20M & L for fabrication includingwelding and fixing in replacement of valve chamber cover made out of 3mm thick MS sheet duly supported by MS flat 25 X 4mm all around and diagonal for various sizes valves chambers duly fixed with 25X4mm flat and long split at one end embedded in wall and lifting handle of MS flat with suitable size and welded to MS sheet with and incl locking arrangement and painted with approved quality of two coats of enamelled paint over a coat of metalic primer complete all as specified and directed.
21Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
22M & L for brick work with subclass \"B\" bricks, straight or curved on plan n exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
23M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 to be finished even and smooth without using extra lime or cement complete all as specified and directed
24M & L for preparation of new plastered surface of wall and applying three coats of white wash complete all as specified and directed
25M & L for PCC 1:3:6type C2 (using 40mm graded aggregate) in foundation, filling and mass concrete complete all as specified and directed.
26Supply and fixing in replacement of DOL starter suitable for monoblock pumpset of capacity 3 to 5HP, 3 Phase, 415V, 50 Hz complete all as specified and directed.
27Material and labour forcleaning of sedimentation tank 10000 Gln of size 7.35 X 3.5 X 2.05 Metre, draining/washing out complete through wash out pipe, and removing all mud, silt, scales, dirts etc from inside area and cleaningwith bleaching powder, wire brush, broom and sand paper etc and marking date ofcleaning and capacity of tank with synthetic enamel paint complete all as specifiedand directed.
28All as per item no. 27 here-in-before, but cleaning of filteration tank of size 8.1 X 7.35 X 2.7 Metre. Note for item No. 27 & 28 : (i) Rate quoted are inclusive of Removal of Sand & Gravels of different size from filteration plant & depositing at a distance not exceeding 30 mtrs away and leveling it as directed. (ii) Refilling of Sand & Gravels of different size shall be measured & paid saperatly under respective item.
29M&L filter media (Gravel) of size40mm gradedcoarse aggregate (thickness - 400mm) of filterationtankcomplete all as specifiedand directed.
30M&L filter media (Gravel) of size20 mm gradedcoarse aggregate (thickness - 300mm) of filterationtank complete all as specifiedand directed.
31M&L filter media (Gravel) of size10/12.5 mm gradedcoarse aggregate (thickness - 150mm)of filterationtank complete all as specifiedand directed.
32S&F uncharged and non cogulant sand media and marble stone aggregate of 5mm graded (thickness - 100mm - 2 tanks ) in white colour suitable for water filteration bed including removingof oldsilica sand from the siteand depositingaway from tank complete all asspecified and directed.
33M & L for dewatering from semi under ground sump 15000 Glns capacity, cleaning internal walls, bottom surface of sump by removing scales and other foreign materials, scrubbing with coir jute brushes, washing the surfaces with mixture of bleaching powder and water & finally washing with fresh water on walls, bottom surface etc applying two coats of white wash inside and outside as existing colour wash and writing letters on the wall i.e. capacity of tank, Date of cleaning, Due date for next cleaning, etc with synthetic enamel paint complete as specified and directed.
34M & L for dewatering from raw water tank 5000 ltrs capacity, cleaning internal walls, bottom surface of tank by removing scales and other foreign materials, scrubbing with coir jute brushes, washing the surfaces with mixture of bleaching powder and water & finally washing with fresh water on walls, bottom surface etc and writing letters on the wall i.e. capacity of tank, Date of cleaning, Due date for next cleaning, etc with synthetic enamel paint complete as specified and directed.
35M&L for scrubbing, cleaning thoroughly for removing the dirts, sediments, silts etc from the internal surface of storage tanks (Sintex) of capacity 2000 ltrs from bottom and wall by using brushes, bleaching powder and other cleaning materials as directed including writing the words \"TANK CAPACITY AND DATE OF CLEANING\" in capital letters of synthetic enamel white paint over black back ground complete all as specified and as directed.
36M & L for rewinding of motor of capacity 3 HP by taking out old winding wires, cleaning slots and rewinding with PVC insulated copper wire of same size & guage as existing glass sleaves etc and replacement of thrust bearings and testing on completion complete all as specified and directed.
37All as per item serial No 36 here in before but of capacity 5 HP
38Supply and fix in replacement Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe of size 80 mm dia complete all as specified and directed.
39All as per item No 38 above but for 50mm dia
40All as per item No 38 above but for 40mm dia
41All as per item No 38 above but for 25mm dia
42All as per item No 38 above but for 20mm dia
43Supply, Laying and testing in replacement old UNSV 3 layer PP-R polypropylene random copolymer concealed pipes SDR 7.4 (PN-16) & SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R Plain & brass threaded polypropylene random fittings of size 20mm complete all as specified and directed.Note Excavation and earth wrok shall be measured and paid separately.
44All as per ser item No 43 here in before but of size 25mm (outer diameter of pipe) complete all as specified and directed.
45All as per ser item No 43 here in before but of size 32mm (outer diameter of pipe) complete all as specified and directed.
46All as per ser item No 43 here in before but of size 40mm (outer diameter of pipe) complete all as specified and directed.
47All as per ser item No 43 here in before but of size 50mm (outer diameter of pipe) complete all as specified and directed.
48Supply and fixing lagging to pipes used in water supply for plumbing all round with lagging closed cell elastomeric nitrile rubber insulation with pipe section of density 60+20% Kg/cum suitable for PPR pipe of size 20mm dia complete all as specified and directed.
49Supply and fixing lagging to pipes used in water supply for plumbing all round with lagging closed cell elastomeric nitrile rubber insulation with pipe section of density 60+20% Kg/cum suitable for PPR pipe of size 25mm dia complete all as specified and directed.
50Supply and fixing lagging to pipes used in water supply for plumbing all round with lagging closed cell elastomeric nitrile rubber insulation with pipe section of density 60+20% Kg/cum suitable for PPR pipe of size 32mm dia complete all as specified and directed.
51Supply and fixing lagging to pipes used in water supply for plumbing all round with lagging closed cell elastomeric nitrile rubber insulation with pipe section of density 60+20% Kg/cum suitable for PPR pipe of size 40mm dia complete all as specified and directed.
52Supply and fixing lagging to pipes used in water supply for plumbing all round with lagging closed cell elastomeric nitrile rubber insulation with pipe section of density 60+20% Kg/cum suitable for PPR pipe of size 50mm dia complete all as specified and directed.
53M & L for providing aluminium cladding over insulation of PPR pipe of size 20mm dia with aluminium sheet having thickness 0.2mm complete all as specified and directed.
54M & L for providing aluminium cladding over insulation of PPR pipe of size 25mm dia with aluminium sheet having thickness 0.2mm complete all as specified and directed.
55M & L for providing aluminium cladding over insulation of PPR pipe of size 32mm dia with aluminium sheet having thickness 0.2mm complete all as specified and directed.
56M & L for providing aluminium cladding over insulation of PPR pipe of size 40 mm dia with aluminium sheet having thickness 0.2mm complete all as specified and directed.
57M & L for providing aluminium cladding over insulation of PPR pipe of size 50 mm dia with aluminium sheet having thickness 0.2mm complete all as specified and directed.
58Taking down and S& F PP-R Gate valves (brass insert) as per requirement of the site of size 20mm dia bore (outer dia of pipe in mm) compete all as specified and directed.
59Taking down and S& F PP-R Gate valves (brass insert) as per requirement of the site of size 25mm dia bore (outer dia of pipe in mm) compete all as specified and directed.
60Taking down and S& F PP-R Gate valves (brass insert) as per requirement of the site of size 32mm dia bore (outer dia of pipe in mm) compete all as specified and directed.
61Taking down and S& F PP-R Gate valves (brass insert) as per requirement of the site of size 40mm dia bore (outer dia of pipe in mm) compete all as specified and directed.
62Taking down and S& F PP-R Gate valves (brass insert) as per requirement of the site of size 50 mm dia bore (outer dia of pipe in mm) compete all as specified and directed.
63Supply & fixing in replacement PP-R Ball Valves (brass inserted) suitable for PPR pipe line of size 20mm complete all as specified and directed.
64Supply & fixing in replacement PP-R Ball Valves (brass inserted) suitable for PPR pipe line of size 25mm compete all as specified and directed.
65Supply & fixing in replacement PP-R Ball Valves (brass insert) as per requirement of the site of size 32 mm dia bore (outer dia of pipe in mm) compete all as specified and directed.
66Supply & fixing in replacement PP-R Ball Valves (brass insert) as per requirement of the site of size 40 mm dia bore (outer dia of pipe in mm) compete all as specified and directed.
67Supply and fixing in replacment ball brass valves, high pressure with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, 25 mm bore dia with rod complete all as specified and directed.
68S&F in replacment Rotational moulded poly-ethylene water storage tanks (cylinderical vertical with closed top) of capacity 2000 Ltr hoiseted and fixed in position complete all as specified & directed.
69S&F in replacment Rotational moulded poly-ethylene water storage tanks (cylinderical vertical with closed top) of capacity 5000 Ltr hoiseted and fixed in position complete all as specified & directed.
70S&F in replacement PUF insulated cylndrical tank of capacity 500 Ltr Vertical type double layer duly filled with puf insulation superior quality to resist in temp -30 to +35 degree centigrade alongwith hinged top lid of same material with locking arrangement and hoisted on platform complete with making pipeline connection with the following specificationcomplete all as specified & directed. :-
71(a) Inner tank will be double layered HDPE food grade material.
72(b) Outer 4mm thick FRP jointless casing of tank.
73© Thickness of PUF insulation shall be 75mm.
74(d) Minimum density of PUF insulation shall be 44 kg per/cum+ 10%.
75S&F PUF insulated cylndrical tank of capacity 1000 Ltr Vertical type double layer duly filled with puf insulation superior quality to resist in temp -30 to +35 degree centigrade alongwith hinged top lid of same material with locking arrangement and hoisted on platform complete with making pipeline connection with the following specificationcomplete all as specified & directed. :-
76(a) Inner tank will be double layered HDPE food grade material.
77(b) Outer 4mm thick FRP jointless casing of tank.
78(c ) Thickness of PUF insulation shall be 75mm.
79(d) Minimum density of PUF insulation shall be 44 kg per/cum+ 10%.
80M&L for opening and rewinding of electric motor 10 HP, 50 Hz 400/ 415 volts of mono block/ centrifugal electric motor of any make and type with super enameled copper winding wire of existing size including bearing bushes and other accessories etc required to make motor functional and testing on load and closing the motor after rewinding including transportation to workshop and back at site complete all as specified and as directed.
81M&L for scrubbing, cleaning thoroughly for removing the dirts, sediments, silts etc from the internal surface of Puff storage tanks of capacity upto 500 ltrs from bottom and wall by using brushes, bleaching poder and other cleaning materials as directed including writing the words \"TANK CAPACITY AND DATE OF CLEANING\" in capital letters of synthetic enamel white paint over black back ground complete all as specified and as directed.
82M&L for scrubbing, cleaning thoroughly for removing the dirts, sediments, silts etc from the internal surface of Puff storage tanks of capacity upto 1000 ltrs from bottom and wall by using brushes, bleaching poder and other cleaning materials as directed including writing the words \"TANK CAPACITY AND DATE OF CLEANING\" in capital letters of synthetic enamel white paint over black back ground complete all as specified and as directed.
83M&L for precast cement concrete block masonary in 1:3:6 type C1 using 20 mm graded stone aggregate with solid block exc. 10 cm width and setting in CM 1:6 complete all as specified and directed.
84M&L for PCC 1:3:6 type C1using 20mm graded stone aggregate as in coping, completeall as specified and directed.
85Note:- The total shall subject to adjustment of credit of Rs99,744.50 for old Materials as per Schedule of Credit.

AI Tender Summary

OUR REF NO 37451625
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 25 Lakhs
LAST DATE 26-05-2023
Authority
Authority Name Military Engineer Services
Work Description Repair / Maintenance Of External Water Supply Pipe Lines, Control Valves, Pump Motors And Other Connected Works At Karcham And Poari Under Age E / M ( We ) In Ge 863 Ews And Repair / Maintenance Of External Water Supply Pipelines, Control Valves And Other Connected Works At Poohunder Age E / M ( We ) In Ge 863 Ews.
Basic Detail
Tender No GE863/EWS-T-14 OF 2023-24
Bidding Type Tender
Location
City karcham
State Himachal Pradesh
Key Dates
Publish Date 19 May 2023
Submission Date 26 May 2023
Open Date 29 May 2023
Finance
Tender Value 25 Lakhs
Tender Fee 500
EMD 50000
Exemption Not Available
Document List
b2bbd659-1df3-457f-aae2-6d626aafa661.html
BOQ_663169.xls
TD_14.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 19, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
May 19, 2023
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
May 26, 2023
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
May 26, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 29, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

b2bbd659-1df3-457f-aae2-6d626aafa661.html

xls

BOQ_663169.xls

pdf

TD_14.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders