National Institute Of Technology-NIT has published Tender For Supply, Installation, Testing, And Commissioning Of Vrf/Vrv-Based Hvac Systems Including Civil And Allied Works In The Various Blocks Of Nit Srinagar. Submission Date for this Tender is 12-07-2023. Earth Moving Machinery Tenders in srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 12-May-2023 | Amendment in Critical Dates | Date | 31-05-2023 |
2 | 19-May-2023 | Critical Dates | Date | 07-06-2023 |
3 | 26-May-2023 | Critical Dates amendment | Date | 16-06-2023 |
4 | 06-Jun-2023 | amendment in Critical Dates | Date | 21-06-2023 |
5 | 13-Jun-2023 | Critical Date | Date | 03-07-2023 |
6 | 21-Jun-2023 | Revised Critical Dates | Date | 12-07-2023 |
7 | 26-Jun-2023 | Techno-Commercial Ammendment | Technical Bid | 12-07-2023 |
Sl. No. | Item Description |
1 | VRF Outdoor Units 28 HP |
2 | VRF Outdoor Units 60 HP |
3 | VRF Outdoor Units 24 HP |
4 | VRF Outdoor Units 22 HP |
5 | VRF Outdoor Units 92 HP |
6 | VRF Outdoor Units 72 HP |
7 | VRF Outdoor Units 32 HP |
8 | VRF Outdoor Units 20 HP |
9 | VRF Outdoor Units 36 HP |
10 | VRF Outdoor Units 34 HP |
11 | VRF Outdoor Units 30 HP |
12 | VRF Floor Mounted 8TR |
13 | VRF Floor mounted ductable type Indoor 6 TR |
14 | VRF Floor mounted ductable type Indoor Unit 8 TR |
15 | VRF Floor mounted 12.8 TR |
16 | Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. |
17 | Supplying & fixing of powder coated extruded aluminium Return Air/Exhaust Air Grills with louvers but without volume control dampers complete as required. |
18 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet as required of Thickness 0.80 mm Sheet |
19 | Ceiling Mounted Round/4way flow Cassette type Unitof 4 TR |
20 | Ceiling Mounted Round/4way flow Cassette type Unitof 3.0 TR |
21 | Ceiling Mounted Round/4way flow Cassette type Unitof 2.5 TR |
22 | Ceiling Mounted Round/4way flow Cassette type Unitof 2.0 TR |
23 | Ceiling Mounted Round/4way flow Cassette type Unitof 1.5 TR |
24 | VRF Ceiling mounted ductable type Indoor unit of 4.5 TR |
25 | Indoor VRF/VRV Units (Nominal Capacity) - Ceiling Mounted Round/4way flow Cassette type Unitof 2.0 TR |
26 | Hi Wall type Unit 1.0 TR |
27 | Hi Wall type Unit 2 TR |
28 | Hi Wall type Unit 1.5 TR |
29 | Refrigerant Piping for VRF system (41.3 mm dia with 19mm thick insulation) |
30 | Refrigerant Piping for VRF system (34.9 mm dia with 19mm thick insulation) |
31 | Refrigerant Piping for VRF system (28.6 mm dia with 19mm thick insulation) |
32 | Refrigerant Piping for VRF system (22.2 mm dia with 19mm thick insulation) |
33 | Refrigerant Piping for VRF system (19.1 mm dia with 13mm thick insulation) |
34 | Refrigerant Piping for VRF system (15.9 mm dia with 13mm thick insulation) |
35 | Refrigerant Piping for VRF system (12.7 mm dia with 13mm thick insulation) |
36 | Refrigerant Piping for VRF system 9.5 mm dia with 13mm thick insulation) |
37 | Refrigerant Piping for VRF system (6.4 mm dia with 13mm thick insulation) |
38 | Cost on account of charging of refrigerant in the piping circuit |
39 | Supply, Installation, testing and commissioning of necessary fittings, Y-joints and headers etc. |
40 | Drain Piping for VRF IDUs 50 mm dia with 9 mm thick insulation |
41 | Drain Piping for VRF IDUs 40mm dia with 9 mm thick insulaton |
42 | Drain Piping for VRF IDUs 32 mm dia with 9 mm thick insulation |
43 | Drain Piping for VRF IDUs 20mm dia with 9 mm thick insulation |
44 | Electric Control Panels |
45 | Centralised Remote Controller |
46 | 4c x 16 mm², copper Electric cables |
47 | 4c x 4 mm², copper Electric cables |
48 | 4c x 6 mm², copper Electric cables |
49 | 3c x 1.5 mm², copper Electric cables |
50 | 2c x 1.5 mm², copper Electric cables |
51 | Cable Trays:- Providing and fixing of hot dip galvanised perforated/ladder cable Trays of 150mm in width and 50mm depth (16SWG) perforated type |
52 | Cost on account of providing & fixing of ACP conduit to completely conceal the refrigerant piping circuit including cable trays etc. |
53 | Earth work in excavation by mechanical means (Hydraulic excavator) |
54 | Providing & laying of Stone Soling tightly hand packed including watering, ramming & carriage from source to site of work complete job. 100 mm nominal size. |
55 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering – |
56 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement – All work up to plinth level. |
57 | P.C.C (1:2:4) Foundation Wall |
58 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement |
59 | Steel reinforcement for R.C.C. work including straightening, cutting ,bending, placing in position and binding all complete upto plinth level. “Cold twisted bars” |
60 | Centering and shuttering including strutting, propping etc. and removal of form forWalls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
61 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
62 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc. |
63 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work,all complete. |
64 | Providing and Fixing of poly coated sheets corrugated 0.50 mm thick complete in all respects. |
65 | Providing & fixing poly coated plain sheet0.80 mm thick ridge. |
66 | Providing and fixing of Plain Eaves Boardingcomplete job including two coats of painting and one coat of priming(1st Class Budloo wood) |
67 | Dismantling of Gypsum board ceiling including stacking of serviceable material and disposal of unserviceablematerial,complete job. |
68 | Providing and fixing 10mm to 12 mm thick Gypsum board ceiling (white) 2´.0?×2´.0? of same pattern as per existing complete in all respects include cost of frame work. |
69 | 800kVA OLTC Transformer with RTCC |
70 | HT PANEL (Complete Job) |
71 | LT Panel (Complete Job) |
72 | Power Pack |
73 | APFC Panel 225 kVAR (Complete Job) |
74 | HT Cable (Supplying and Laying of one No. HT. cable of 11 KV grade XLPE armoured Al. |
75 | HT Cable (Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories.) |
76 | HT Cable (Supply, Installation, Testing & commissioning of Trivector meter and PT of 11kV/110Vfor 800kVA Transformerenclosed in cubicle panelmade of 1.6mm thick CRCA sheet |
77 | LT Cable (Supply and Laying of PVC Insulated and FRLS PVC round sheathed, armoured solid single core copper cable of 300 sq mm industrial cable of 1.1kv grade ) |
78 | 3 core 1.5 sq mm cable (LT Cable) |
79 | 3 core 2.5 sq mm cable(LT Cable) |
80 | 3 core 4 sq mm cable(LT Cable) |
81 | 3 core 6 sq mm cable (LT Cable) |
82 | 3.5c × 50 sq mm (LT Cable) |
83 | 3.5c × 70 sq mm (LT Cable) |
84 | 3.5c × 95 sq mm (LT Cable) |
85 | 3.5c × 150 sq. mm (LT Cable) |
86 | 3.5c × 185 sq. mm (LT Cable) |
87 | (OD)/ (ID) 50mm/ 39mm |
88 | (OD)/ (ID) 90mm /76mm |
89 | (OD)/(ID)120mm/103mm |
90 | Supplying, installation, testing & commissioning of OUTDOOR Panel factory assembled Dust & Vermin Proof wall / floor mounted LT cubical type compartmentalizedpanel inclu |
91 | Supplying, installation, testing & commissioning of OUTDOOR Panel factory assembled Dust & Vermin Proof wall / floor mounted LT cubical type compartmentalizedpanelcomplete as required. |
92 | P/F of 4- pole, 250 Amp. MCCB (Adjustable type) lcu = 36kA with Ics = 100% Icu as per IEC 60947-2 including spreaders of same rating. Complete in all respects. |
93 | P/F of 4- pole, 100 Amp. MCCB (Adjustable type), lcu = 25kA with Ics = 100% Icu as per IEC 60947-2 including spreaders of same rating. Complete in all respects. |
94 | P/F of 63Amps. 4P MCCB of breaking capacity 25 KAwith thermal magnetic releaseICU=Ics=100% |
95 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure |
96 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode |
97 | Bridge Earthing for Power station and DG Sets: P/F of Maintenance free Chemical Earthing using copper Electrode |
98 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating |
99 | Supply, Installation, Testing And Commissioning of 3_Phase 320 kVADG Set with AMF Panel |
100 | Supply, Installation, Testing And Commissioning of 3_Phase 250 kVADG Set with AMF Panel |
101 | Supply, Installation, Testing, Commissioning of factory fabricated high quality steel Diesel storage tank above the ground modular |
102 | P/F of 1600 VA square wave Inverter of Luminous/Amaron/Exide with all accessories including battery rack |
103 | P/F of Tall Tubular 200Ah Battery, 12V Tubular battery of Exide/Amaron, or equivalent make Battery including suitable plastic trolley along with brass terminals in all respects. 3 Years warranty |
104 | P/F of 1200 mm sweep Metallicceiling fan with 300 watt 5 step regulator of and hook for fan. |
105 | P/F of 300 mm Sweep Heavy Duty Crompton Greaves Exhaust Fan (metal type)Complete in all respects. |
106 | P/F of 2 ft*2ft LED luminaries with URG <19 recess mounted with high lumen output with durable housing with Al heat sink with Diffuser to give glare free light with removable driver. |
107 | Supplying & Fixing of Charging Point ofmodular switch. Complete the job in all respects. |
108 | Supplying & fixing following modular switch of 25 Amp, Socket outletcomplete the job in all respects. |
109 | Wiring for light point / fan point /exhaust point / call bell point with 1.5 sq. mm FRLS PVC insulated Copperas required. |
110 | Supplying and fixing 5A to 32 A rating, 240/415 V, 10 kA, “C”curve (Single Pole) |
111 | Supplying and fixing 5A to 32 A rating, 240/415 V, 10 kA, “C”curve, . (Double Pole) |
112 | Supplying and fixing 63 A rating, 240/415 V, 16kA “C”curve, complete |
113 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board,complete in all respects |
114 | Supply, Installation, Testing and Commissioning of 7/8 mtrs long octagonal poleComplete in all respects. |
115 | Supply , installation ,Testing and commissioning of 100W , 10000 lm Smart Bright LED Flood Lightcomplete in all respects. |
116 | Supply and fixing of ABC powder based type fire extinguishers complete as required |
117 | Supply and Testing of all safety equipment and necessarypower station equipment tools |