Tender For Provision Of Ro And Water Cooler In Frro Complex Sewa Sadan Lampur Delhi110040.
Tender Value
3.75 Lakhs
Estimated cost
Bid Submission
06 May 2023
0 days left
EMD
7502
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Provision Of Ro And Water Cooler In Frro Complex Sewa Sadan Lampur Delhi110040.
BOQ
| Sl. No. | Item Description |
| 1 | S.I.T.C of self-contained drinking water cooler in stainless steel body ISI mark food grade wall water piping and other components which come in contact with water, non corrosive adjustable pedestal, complete with refrigerant cooling capacity 150 Ltr/Hr. storage type of capacity 150 Ltr, suitable for operation on 230 Volts +10%. 50 Hz, AC supply including fixing on angle iron frame work stand of size 35mm x 35mm x 5mm thick suitable height including water intel & outlet connection etc. as required. |
| 2 | Supplying Installation Testing Commissioning of reverse osmosis plant of 250 LPH capacity including all plumbing with suitable UPVC pipes of all sizes required in this system, fittings, fixtures, unions, joints, flow meters for waste and clean water, pressure switch (Low & High), pressure gauges, motorpump sets, media, PLC controller, SS skid to make the system complete in all respect, making foundation, grouting including supplying & fixingthe following on the foundation and skid,complete etc as reqd.Monoblock raw water motor pump set operating on single phase approx. 25 LPM, 3 meters head of suitable HP - 1 No.Self standing dual media filter 12\" X 48\" with all accessories, filled with gravels, pebbles, coarse sand to appropriate level- 1 No.Activated carbon vessel of size 12\" X 48\" with all accessories, filled with activated carbon of 900 iodine grade upto appropriate level etc.-1 No.Anti-scaling dosing system complete with 1.5 LPH pump with 100 litres tank complete with all mountings, fittings. etc - 1 No.Micron filter cartridge for restraining particles size greater than 5 micron of size 20\"enclosed in big blue housing with cap and all mountings etc. as reqd. - 1 No.Vertical multistage high pressure SS body centrifugal pump suitable tooperate on 220 volt at a discharge pressure not less than 13 kg per sq. cm complete with all accessories and mounting arrangements etc. - 1 No.Spiral type R.O. Membrane TFC type of size not less than 4\" dia, 40\" long complete provided in dual membrane housing with end caps & accessories & mountings complete etc.- 1 No.Pressure gauges (0-25) Kg per sq. cm.Auto flushing systemincluding 0.5 inch solenoid valve, operating on 220 Volt through PLC panel command -1 SetRota meter - 2 Nos.Programmable logical control panel for the automation of the system complete with following accessories:-i) LCD Display for measuring TDS and conductivity 1 No.ii) Single Phase DOL Starters with overload relay 2 Nos.iii) Online indicating lights - for motor, raw water level indicator LPS, HPS & clean water status etc.iv) Auto/ Manual Switchv) Auto flush system R.O. Membrane at each start,vi) Input MCB 20/32 Amp - 2 Nos.vii) Indication Lights - 6 Nos.viii) PLC module with all accessories etc - 1 No. |
| 3 | Providing and fixing Chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointingof pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in chargea) 25 mm nominal outer dia Pipes |
| 4 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.a) 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 6 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-chargea) All kinds of soil |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level a) 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 8 | Brick work with common burnt clay selected F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand) a) From ground level upto plinth level |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level a) 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 10 | 12 mm cement plaster of mixa) 1:4 (1 cement: 4 fine sand) |
| 11 | Finishing walls with Acrylic Smooth exterior paint of required shade a) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 12 | Fabricating, supplying and fixing of wire mesh protection frame work fabricating with 40 x 40 x 6 mm thick angle iron/Tee iron having intermediate members of size 25 mm x 6 mm (GI wire should be 6SWG) flat strip welded at 30 cm in each sections & duly welded with hard drawn wire fabric mesh of size 25 mm X 75 mm having weight not less than 7.5 Kg/Sqmtr. and making main door gate provided with two nos. sliding bolt with godown locks with operating handle welded from inside of the door i/c providing and fixing of four no. legs of same angle size of 90 cm length duly grouted infoundation (30 x 30 x 45) cm (deep) in 1:2:3 cement concrete & painting with one coat of red oxide & two coat of super synthetic luminous paint of approved colour and quality etc. complete as reqd. {Area of hard drawn wire fabric with angle (Except legs) shall be measured for payment} |
| 13 | S/I/T/C of fibreglass sheet having steel wire reinforcement 2 mm thickness on the existing wiremesh encloser on roof with the help of steel screw, washer, steel nut bolt and clamp etc. as required |
AI Tender Summary
Tender Timeline
Apr 28, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedMay 06, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMay 06, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer