Tender For Supplying, Installing, Testing, And Commissioning Of G Plus 3 Elevator (Lift) And Allied Works For 4-Storeyed Research Hostel At Zakura Campus., zakura-Jammu And Kashmir

University Of Kashmir (Jammu) has published Tender For Supplying, Installing, Testing, And Commissioning Of G Plus 3 Elevator (Lift) And Allied Works For 4-Storeyed Research Hostel At Zakura Campus.. Submission Date for this Tender is 17-05-2023. Passenger Lift Tenders in zakura Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

37442025
Corrigendum : Tender For Supplying, Installing, Testing, And Commissioning Of G Plus 3 Elevator (Lift) And Allied Works For 4-Storeyed Research Hostel At Zakura Campus.
Open Tender
Indian
Jammu And Kashmir
zakura
17-05-2023

Tender Details

Supplying, Installing, Testing, And Commissioning Of G Plus 3 Elevator (Lift) And Allied Works For 4-Storeyed Research Hostel At Zakura Campus. , Design , Supply , Installation , Testing And Commissioning Of Passenger Elevator Including System Control Panel And With Following Specifications Including All Necessary Chanelles/Rollers/Rails And All Otheraccessories Complete, Should Have Also Following Technical Parameters: Note: Freemaintenance For Twelve Months.The Period Of Thismaintenance Shallcommence From The Date Ofhanding Over Of The Lift. Capacity / Load:8 Persons (Gear Less Mrl) Speed: 1 Mps, Type Of Drive: Vf Regenerative (Closed Loop) Rise (M): As Required Serving: Gf , 1St , 2Nd, 3Rd ,Stops: 4 Controller Type: Acd3-Mrl/Eq.Power Supply: 400/415 Volts 3Phase Operation: Fully Collective , Car Group: One Car (Simplex) With Controller Panel Machine: Pm Gearless ( Located In Shaft On Top Of Guide Rails) Ventillation: Cross Flow Fans No. Of Car Entrance: One Location Front At All Floors Hoistway/ Car Entrance Door: Centre Opening, Glass , Ss Hairline Finish Traction Media: Flate Coated Steel Belt Operation: Automatic, Ard(Auto Rescue Device) System Control: Simplex False Ceiling Type: Cd-41/Eq,False Ceiling Finish: Stainless Steel Hand Rails: Stainless Steel Mirror Finish On All Sides Of Car Panels Flooring: Granite,Car Door Finish: Stainless Steel Landing Door Finish: Stainless Steel Car & Hoistway Door Type: Central Operating (Co) Doors Cop: Cop For Stops= 12(950Mm) In Stain Less Steel Car Position Indicator/Hall Button Arrangements: Lcd Monochromedotmatrix Multi Color , Providing And Fixing Of Lighting Point In Loop Wiring For Lift With 1.5 Mm2 Pvc Insulated Copper Wire Of Frlsthrough Pvc Conduit Pipe/ Pvc Channel With All Necessary Accessories Including Providing And Fixing Of Ceiling Rose Ofwithround Junction Plate 5Amp Switchesrecessed In Wall Using Modular Plate Of Required Size, Point Taken Upto D.B. Duly Tested And Commissioned, Including Holder Etc. , Providing And Fixing Of Led Bluck Heads9 Watt , Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Cb/Rccb/Isolator) 12 Way , Double Door , Supplying And Fixing Following Rating, Tpn, 415 V, Mcb In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required 63 A , Supplying And Fixing 6 A To 32 A Rating, 240/415 V, 10 Ka, “C”-Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , Supply, Installation, Testing And Commissioning Of 20Kva Servo Stabilizer Digital Microcontroller Servo Voltage Stabilizer In-Door Typewith Fresh Dehydrated Oil. With Protection, Complete In All Respects. Technical Specifications Of 3 Phase Servo Stabilizer: Capacity :20Kva, Type :Un-Balanced 4 Wire System( With Buck- Boost Transformer) Method Of Cooling : Oil Cooled,Phase : 3 Phase, 4 Wire,Frequency :50 Hz, Input Voltage : (P-P) 280-460 (P-P),Output Voltage :415 V +-1%,Efficiency : 98% At Full Load, Operation Temperature : 45 Degree Celsius Above Ambient Relative Humidity : Up To 90%, Correction Speed : Up To 35 V/Sec No Load Current : Less Than 1.5% Of Rated Current Bbt : Crgo Core Material 0.23Mm Thickness Metering : Lcd , Analogue Or Digital ( As Per Requirement), Indication : Indicators For Phase Failure, Over-Load And Over-Voltage Controls : Auto/Manual Selector Switch, Increase Decrease Toggle Switch For Manual Operation, Output Switch Protection : Input High And Low Cut Off, Output High And Low Cut Off, Overload, Short-Circuit Protection, Time Delay Protection,Class Of Insulation : “A”,Fabrication Box Paint : 7 Process Powder Coated,System Construction : As Per Is 9815 Independent Phase Control : Maintain Each Phase Voltage Stable Irrespective Of Unbalancedload, Transformer Winding : Copper 99.9% Pure,Duty Cycle : 100%, Container: 14 Swg With Stove Enamelled Paint, Cable Box And Busses :Bar Suitable Size Of Cable Box With 6 Aluminium Busbars (3 For Input, 3 For Output And 1 For Neutral),Regulator : Toroidal Type, Oil Capacity : As Required Paint : Powder Coated, Color : Ral 7035 (Polyester Powder Coating) System Construction : As Per Is-9815 , Supply Of Advance Maintenance Free Chemical Gel Earthing Of Dual Pipe Technology (Gi) Of 3 Mtrs Long 80 Mm Dia Of Outer Shell (Ms) With The 50 Mm Dia Of Inner Shell (Ms) Of 80-100 Microns Galvanized Chemrode Filled With Highly Conducting Metallic Compounds With The Permenant Sealings At Both The Ends With The Lead Terminal Of 50X10mm Size At The Top. The Electrode Shall Be Duly Tested And Certified By Cpri (Central Power Research Institute), Govt Of India For A Peak Short Circuit Withstanding Capacity Of 60 Ka. Including Supply/ Fixing Of Environment Friendly Rust Proof Heavy Duty Weather Proof Polyplastic Earth Pit Chamber. , Providing And Fixing Of Heating Points For Lift Using 4 Sq.Mmpvc Insulated Copper Wire Through 1” 2Mm Pvc Conduit/1” Pvc Casing Capping And Providing And Fixing Of 6/16 Amp. Of Modularswitch/Socket Recessed In Wall Covered With Modular Sheet/ Ms Boxof Required Size Including Providing And Fixing Of 4Mm² Pvc Insulated Copper Wire T As Earth Wire, Point Taken Up To D.B. Duly Tested And Commissioned, Complete Point In All As Pects , Wiring For Circuit (Lift)/ Submain Wiring Along With Earth Wire With The Following Sizes Of Fr Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed In Class Heavy Duty Pvc Conduit As Required ) Note : Rates Of Suitable Pvc Conduitincluded In Above Description For The Follwing Items Ofmake 4 X 10 Sq. Mm + 1 X 10 Sq. Mm Earth Wire , Supplying, Fixing, Testing And Commissioning Of 4P On Load Change Over Switch Wall Mount Front Operation , Providing, Fixing, Testing And Commissioning Of Tpn 63A Rccb 100-300Maincluding Double Door Enclosure Suitable For Rccb As Per Requirement , (Ssr6.1) Brick Work With Common Burnt Clay (Non-Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth Including Curing In : 6.1.1 Cement Lime Mortar 1:1:6 ( 1 Cement : 1 Lime Putty : 6Fine Sand) , Extra For Brick Work In: (Ssr6.6.1) Square Or Rectangular Pillars , Cement Plaster In Two Coats (Ssr 13.12) 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1 : 5 (1 Cement : 5 Coarse Sand) Finished With A Top Layer 6Mm Thick Cement Plaster 1 : 6 (1 Cement : 6 Fine Sand) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Upto 15°,Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Upto Five Level Including Curing But Excluding The Cost Of Centring, Shuttering,Finishing And Reinforcement With (Ssr5.3.1) 1:1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level (5.22A.6) Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work Ssr13.69) , Marble Work Gang Saw Cut (Polished And Machine Cut) Of Thickness 16 Mm For Wall Lining (Veneer Work), Backing Filled With A Grout Of 12 Mm Thick Average In Cement Mortar 1:3 (1Ce Ment: 3 Coarse Sand), Including Pointing With White Cement Mortar 1:2 (1 White Cement: 2 Marble Dust) With An Admixture Of Pigment To Match The Marble Shade (To Be Secured To The Backing By Means Of Cramps, Which Shall Be Paid For Separately). (Ssr)8.1.1.2 (Area Of Slab Over 0.5 Sqm) , C.G.I. Sheets Roofing Providing Corrugated G. S. Sheet Roofing Including Vertical/Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8Mm Diameter With Bitumen And G.I Limpet Washers Or With G.I. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Upto Any Pitch In Horizontal/Vertical Or Curved Surface)Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. (Ssr12.1.1) 1.60 Mm Thick With Zinc Coating Not Less Than 350 Gram/M2 , Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. (Ssr10.25.2) In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works. , Providing, Fixing And Cladding With 3 Mm Thick Matt Finish Aluminium Composite Panel With All Fixing Arrangements On Lift Wallwith Hinges/Catchers Etc As Per Sie Requirement. , Note. The Quoted Percentage (%Age) Should Preferably Be In Fractional Form In Order To Minimize Concurrence Of Similar Quoted Rates

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-May-2023 NIT Corrigendum Other 08-05-2023
2 08-May-2023 Date Extension Notice Date 17-05-2023

Key Value

Document Fees
INR 1100 /-
EMD
INR 56400.0 /-
Tender Value
INR 28.20 Lakhs /-

BOQ Items

Name of Work: Supplying, Installation, Testing and Commissioning of G+3 Elevator (Lift) and allied works for 4 Storeyed Research Hostel at Zakura Campus (Advertised cost Rs. 28.20 Lacs)
Sl. No. Item Description
1"Design , Supply , Installation , Testing and Commissioning of Passenger Elevator including system control panel and with following specifications including all necessary Chanelles/rollers/rails and all otheraccessories complete, should have also following technical parameters: Note: Freemaintenance for twelve months.The period of thismaintenance shallcommence from the date ofhanding over of the lift. " Capacity / Load:8 Persons (Gear Less MRL) Speed: 1 MPS, Type of drive: VF Regenerative (closed loop) Rise (m): as required Serving: GF , 1st , 2nd, 3rd ,Stops: 4 Controller type: ACD3-MRL/eq.Power Supply: 400/415 Volts 3Phase Operation: Fully collective , Car group: One car (simplex) with controller panel Machine: PM Gearless ( located in Shaft on top of guide rails) Ventillation: Cross flow fans No. of Car entrance: One location front at all floors Hoistway/ Car entrance door: Centre opening, Glass , SS Hairline finish Traction Media: Flate Coated steel Belt Operation: Automatic, ARD(Auto rescue Device) System Control: Simplex False ceiling Type: CD-41/eq,False ceiling Finish: Stainless steel Hand rails: Stainless steel Mirror Finish on all sides of car Panels Flooring: granite,Car door finish: Stainless steel Landing door finish: Stainless steel Car & Hoistway Door Type: Central Operating (CO) doors COP: COP for Stops= 12(950mm) in stain less steel Car position indicator/Hall button arrangements: LCD MonochromeDotmatrix multi color
2Providing and fixing of Lighting point in loop wiring for lift with 1.5 mm2 PVC insulated copper wire of FRLSthrough PVC conduit pipe/ PVC channel with all necessary accessories including providing and fixing of ceiling rose ofwithround junction plate 5Amp switchesrecessed in wall using Modular plate of required size, point taken upto D.B. duly tested and commissioned, including holder etc.
3Providing and Fixing of LED Bluck Heads9 Watt
4Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without CB/RCCB/Isolator) 12 way , Double door
5Supplying and fixing following rating, TPN, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 A
6Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole
7Supply, Installation, Testing and Commissioning of 20KVA servo stabilizer Digital Microcontroller Servo Voltage Stabilizer In-door typewith fresh dehydrated oil. With protection, complete in all respects. Technical Specifications of 3 Phase Servo Stabilizer: Capacity :20KVA, Type :Un-Balanced 4 wire system( with Buck- Boost Transformer) Method of Cooling : Oil Cooled,Phase : 3 Phase, 4 wire,Frequency :50 Hz, Input Voltage : (P-P) 280-460 (P-P),Output Voltage :415 V +-1%,Efficiency : 98% at full load, Operation Temperature : 45 Degree Celsius above ambient Relative Humidity : Up to 90%, Correction Speed : Up to 35 V/sec No load current : Less than 1.5% of rated current BBT : CRGO core material 0.23mm thickness Metering : LCD , Analogue or Digital ( as per requirement), Indication : Indicators for phase failure, over-load and over-voltage Controls : Auto/Manual Selector Switch, Increase Decrease Toggle Switch for Manual Operation, Output Switch Protection : Input High and low cut off, Output High and low cut off, Overload, Short-circuit protection, Time Delay Protection,Class of Insulation : “A”,Fabrication Box Paint : 7 Process Powder Coated,System construction : As per IS 9815 Independent Phase Control : Maintain each phase voltage stable irrespective of unbalancedload, Transformer Winding : Copper 99.9% Pure,Duty Cycle : 100%, Container: 14 SWG with Stove enamelled paint, Cable Box and Busses :BAR suitable size of cable box with 6 aluminium busbars (3 for input, 3 for output and 1 for neutral),Regulator : Toroidal Type, Oil capacity : As required Paint : Powder Coated, Color : RAL 7035 (Polyester Powder Coating) System Construction : AS per IS-9815
8Supply of advance maintenance free Chemical Gel Earthing of Dual Pipe Technology (GI) of 3 mtrs long 80 mm dia of outer shell (MS) with the 50 mm dia of inner shell (MS) of 80-100 microns galvanized CHEMRODE filled with highly conducting metallic compounds with the permenant sealings at both the ends with the lead terminal of 50x10mm size at the top. The electrode shall be duly tested and certified by CPRI (Central Power Research Institute), Govt of India for a peak short circuit withstanding capacity of 60 KA. including Supply/ fixing of environment friendly rust proof heavy duty weather proof polyplastic earth pit chamber.
9Providing and fixing of Heating points for lift using 4 sq.mmPVC insulated copper wire through 1” 2mm PVC conduit/1” PVC casing capping and providing and fixing of 6/16 Amp. of ModularSwitch/socket recessed in wall covered with modular sheet/ MS boxof required size including providing and fixing of 4mm² PVC insulated copper wire t as earth wire, point taken up to D.B. duly tested and commissioned, complete point in all as pects
10Wiring for circuit (lift)/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed in class heavy duty PVC conduit as required ) Note : Rates of Suitable PVC conduitincluded in above description for the follwing items ofmake 4 X 10 sq. mm + 1 X 10 sq. mm earth wire
11Supplying, fixing, testing and commissioning of 4P on load Change Over Switch wall mount front Operation
12Providing, fixing, testing and Commissioning of TPN 63A RCCB 100-300mAincluding Double door enclosure suitable for RCCB as per requirement
13(ssr6.1) Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : 6.1.1 Cement lime mortar 1:1:6 ( 1 cement : 1 lime putty : 6fine sand)
14Extra for brick work in: (SSR6.6.1) Square or rectangular pillars
15CEMENT PLASTER IN TWO COATS (SSR 13.12) 18mm Cement plaster in two coats under layer 12mm thick cement plaster 1 : 5 (1 cement : 5 coarse sand) finished with a top layer 6mm thick cement plaster 1 : 6 (1 cement : 6 fine sand)
16Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering,finishing and reinforcement with (SSR5.3.1) 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
17Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level (5.22A.6) Thermo-Mechanically Treated bars of grade Fe-500D or more.
18Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work SSR13.69)
19Marble work gang saw cut (polished and machine cut) of thickness 16 mm for wall lining (veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 (1ce ment: 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). (SSR)8.1.1.2 (Area of slab over 0.5 sqm)
20C.G.I. SHEETS ROOFING Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (SSR12.1.1) 1.60 mm thick with zinc coating not less than 350 gram/m2
21Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (SSR10.25.2) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
22Providing, fixing and Cladding with 3 mm thick matt finish Aluminium composite panel with all fixing arrangements on lift wallwith hinges/catchers etc as per sie requirement.
23Note. The quoted percentage (%age) should preferably be in fractional form in order to minimize concurrence of similar quoted rates