| 1 | Supplying of PVC/XLPE armoured cable with aluminium conductor 1.1KV Gradeconfirming to IS 7098 (part I)1988 with upto date amendments of the following size at the site of work. |
| 2 | 3 1/2 X 35 Sqmm |
| 3 | 4 X16 Sq.mm |
| 4 | 2 X 10 Sq.mm |
| 5 | 3 X 6 Sq.mm |
| 6 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 7 | upto 35 Sq.mm |
| 8 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. |
| 9 | upto 35 Sq.mm(Clamped with 1 mm thick saddle) |
| 10 | Supplying and fixing of light class G.l. pipe of 50 mm dia. (nominal) 3 metres length along the pole/wall for protection of under ground cable as required. |
| 11 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required |
| 12 | 100 mm Dia |
| 13 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 14 | Upto 35 Sqmm |
| 15 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 16 | Group C |
| 17 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 18 | 3 x 4 sq. mm |
| 19 | 3 x 2.5 sq. mm |
| 20 | 6 x 2.5 sq. mm |
| 21 | 3 x 1.5 sq. mm |
| 22 | 6 x 1.5 sq. mm |
| 23 | 9 x 1.5 sq. mm |
| 24 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 25 | 20 mm |
| 26 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator) |
| 27 | 4 way (4 + 12), Double door |
| 28 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 29 | 6 way , Double door |
| 30 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 31 | Single pole |
| 32 | Single pole and neutral |
| 33 | Triple pole and neutral |
| 34 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 35 | Supplyinstallation, Testing and commissioning of 20W LED T8 tube with extruded Al body, PC diffuser and inbuilt driver with efficacy min of 100 lumens/W along with Highly robust Industrial Box type(not compact type) luminaire suitable for twin T8 LED Tube etc.at the site of work.(ISI certified) |
| 36 | Supply, installation, Testing and commissioning of 20W LED T8 tube with extruded Al body, PC diffuser and inbuilt driver with efficacy min of 100 lumens/W along with Highly robust Industrial Box type(not compact type) luminaire suitable for single T8 LED Tube etc.at the site of work.(ISI certified) |
| 37 | Supplying, installation, Testing and commissioning of 20W LED T8 tube with extruded Al body, PC diffuser and inbuilt driver with efficacy min of 100 lumens/W along with Surface/Suspended waterproof industrial luminaire(IP 66) with polycarbonate housing and diffuser suitable for single 4 ft T8 tube etc.at the site of work. (ISI certified) |
| 38 | Supplying, installati+B86on, Testing and commissioning of 70 watt LED type Well Glass Light in pressure die-cast aluminium housing and fixing on truss /wall/ pole with suitable clamps and nut bolts(ISI certified) .. (RatingIP66,Luminare efficacy >110Lm/W,CRI>70). |
| 39 | Supplying, installation, Testing and commissioning of45W LED Street light fitting made up of pressure die cast alluminium housing and fixing on wall/truss/pole with suitable clamps and nut bolts including giving connection etc., at site of work as required.(ISI certified) |
| 40 | Supplying, installation, Testing and commissioning of120W LED flood light fitting made up of pressure die cast alluminium housing and fixing on wall/truss/pole with suitable clamps and nut bolts including giving connection etc., at site of work as required.(ISI certified) |
| 41 | Removing of existing LED Well glass light/LED street light from surface/truss and Refixingthem on Godowns, ancillary buildings with suitable clamps ,nut and bolts etc. including giving connections etc. at site of work as required. |
| 42 | Supplying and fixing of Hot press moulded SMC junction Box of size 140x140x95 with 6A SP MCB, 2/4 way strip connector including testing commissioning etc. as reqd. |
| 43 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required. |
| 44 | 3 1/2 X 35 sq. mm (32mm) |
| 45 | 4 X 16 sq. mm (28mm) |
| 46 | 2 X 10 sq. mm (19mm) |
| 47 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 48 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 49 | Earthing with 60mm outer dia ,2 mtr length GI earthing electrode, completely filled with conductive crystalline compound ,fitted with minimum of 40x6x2000mm GI strip including 50 kgs of eco friendly maintenance free earthing compound to enhance soil conductivity and providing masonry enclosure with cover plate having locking arrangement etc at the site of work as required. |
| 50 | Supplying and fixing 3 pin, 5 A ceiling rose on the existingjunction box/ wooden block including connections etc. as required. |
| 51 | Supplying, installation, Testing and commissioning of 35 watt LED post top (gate light) made up of pressure die cast aluminium housing with IP 65,IK 07, avg life- 50000 hours with lumen efficacy of >140 lm/W, System efficacy of > 70 lm/W,colour temp 5700 K,THD( %) < 10 with high quality polycarbonate diffuser over the LED module including giving connection etc., at site of work as required. (ISI certified) |
| 52 | Supplying and drawing of 1.5 Sq.mm,three core PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conforming to IS: 694 in the existing surface/ recessed steel/ PVC conduit as required. |
| 53 | Design,Fabrication,Supplying, Installation, Testing and commissioning of Dust and vermin proof Cubicle type Feeder pillarsuitable for 3 Phase,415v,50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade and comprising of the following:Complete with aluminium busbars ofadequate capacity for Phases & neutral, Suitable M.S Angle Base Frame of 45 X 45mm, interconnections control wiring, including incoming and outgoing cables connections etc as required at site of work and as directed by the Engineer in charge. Size: 900mm(W)X1100mm(H)X350mm (D) feeder pillar with Aluminium busbar Incoming: 4 pole MCCB 125A,36KA-01No , Outgoing: 4 pole MCCB 63A,36KA-01No, 32A, 4 pole MCB,10KA-02 no\"s,32, 2A Pole MCB, 10KA -03 Nos |
| 54 | Design,Fabrication,Supplying, Installation, Testing and commissioning of Dust and vermin proof Cubicle type Feeder pillarsuitable for 3 Phase,415v,50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade and comprising of the following:Complete with aluminium busbars ofadequate capacity for Phases & neutral, Suitable M.S Angle Base Frame of 45 X 45mm, interconnections control wiring, including incoming and outgoing cables connections etc as required at site of work and as directed by the Engineer in charge. Size: 900mm(W)X1100mm(H)X350mm (D) feeder pillar with Aluminium busbar Incoming: 4 pole MCCB 125A,36KA-01No , Outgoing: 4 pole MCCB 63A,36KA-01No, 32A,2 Pole MCB, 10KA -05 Nos |
| 55 | Design,Fabrication,Supplying, Installation, Testing and commissioning of Dust and vermin proof Cubicle type Feeder pillarsuitable for 3 Phase,415v,50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade and comprising of the following:Complete with aluminium busbars ofadequate capacity for Phases & neutral, Suitable M.S Angle Base Frame of 45 X 45mm, interconnections control wiring, including incoming and outgoing cables connections etc as required at site of work and as directed by the Engineer in charge. Size:1000mm(W)X1300mm(H)X350mm (D) feeder pillar with Aluminium busbarIncoming 4 pole MCCB, 160A, 36KA- 1 No outgoing 4 pole MCCB, 63A, 36KA- 3 No 32A, 4 Pole MCB,10KA - 1 Nos 32A, 2 Pole MCB,10KA - 3 Nos |
| 56 | Design,Fabrication,Supplying, Installation, Testing and commissioning of Dust and vermin proof Cubicle type LT panel boardsuitable for 3 Phase,415v,50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade and comprising of the following:Complete with aluminium busbars ofadequate capacity for Phases & neutral, Suitable M.S Angle Base Frame of 45 X 45mm, interconnections control wiring, including incoming and outgoing cables connections etc as required at site of work and as directed by the Engineer in charge.Size:1000mm(W)X1100mm(H)X350mm (D) Incoming4 pole MCCB, 250A, 36KA- 1 Nooutgoing 4 pole MCCB, 200A, 36KA- 1 Nos4 pole MCCB, 160A, 36KA- 2 Nos32A, 2 Pole MCB,10KA - 4 NosMetering Panneling Digital Voltmeter - 01 Nos Digital Ammeter - 01 Nos RYB phase indication lamps-1 set 6A SP MCB for control Ckts-04 Nos 100/5A CT coils |
| 57 | Providing M.V. danger notice plate of 200 mm X 150mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 58 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long,G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 59 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 60 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete asrequired.(For vertical run) |
| 61 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 62 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level |
| 63 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 64 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade |
| 65 | One or more coats on old work |
| 66 | Dismantling of pole/ street light standard/ strut embedded in brick ballast foundation etc. as required. |
| 67 | Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required. |
| 68 | Dismantling of existing conduit along with aluminium wire, main board, sub-main boards, switch boards and shifting to depot stores etc., as required. |
| 69 | CREDIT ITEMS |
| 70 | Dismantled MS conduit pipe of different sizes, DB’s, GI wire and clamps etc. |
| 71 | Dismantled aluminum wire |
| 72 | Dismantled box type fittings 1X40W/street lights |
| 73 | Dismantled ACSR Consuctors |
| 74 | Dismantled iron electrical poles |