| 1 | Earth work excavation for foundation in all soils and sub soils and to full depth as may be directed except in hard rock requiring blasting but inclusive of shoring, strutting and baling out water wherever necessary and refilling the sides of foundation with excavated earth in layers of 15cm thick well rammed and consolidated & depositing the surplus earth in places shown by departmental officers with an initial lead of 10m and lift of 2m and clearing and levelling the site etc. complete complying with standard specification. |
| 2 | Cement Concrete 1:4:8 (One Cement, Four sand and Eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick, well rammed, consolidated and curing etc. complete complying with standard specification |
| 3 | Supplying and filling in foundation and basement with filling sand in layers of not more than 15cm thick well rammed, watered and consolidated etc., complete complying with standard specification. |
| 4 | Filling in basement with excavated earth in layers of not more than 15cm thick well rammed, watered and well consolidated etc. complete complying with standard specification. |
| 5 | Brick work in CM 1:5 (one cement & five sand) using country bricks of size 8.75\"X4.25\"X 2.75\" including finishing, curing, etc., complete complying with standard specification |
| 6 | Supplying and erecting steel centering including necessary supports for plane surfaces in foundation and basement for reinforced cement concrete works such as column footings, plinth beam, grade beam, stair case steps, bed blocks etc. which require only normal strutting using M.S. sheets of size 90cm x60cm BG 10 gauge of stiffened with mild steel angles of size 25mm x 25mm x 3mm for boarding laid over silver oak joists of size 10 x 6.50cm spaced at about 90 cm centre to centre and supported by the casurina props of 10cm to 13cm dia spaced at 75cm centreto centre atsuitableintervals etc. complete as per standardspecification. |
| 7 | Supplying and erecting, centering for sides and soffits including supports and strutting upto 3.29m height for plane surfaces as detailed below in all floors with all cross bracings using mild steel sheet of 90cm x60cm BG 10 gauge stiffened with welded M.S. angle of 25 x 25 x 3mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10 cm to 13 cm dia spaced at not less than 75 cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specification.(The payment for centeringshall be made only after the concrete is laid. The retrieved materials should be taken back by the contractor) Lintel & Columm & Roof |
| 8 | Supplying, fabricating and placing in position M.S. or R.T.S. reinforcements grill for RCC works as per the design given including cost of steel and binding wire etc., complete complying with standard specification. (The contractor will have to make his own arrangements for the supply of M.S. plain rods / RTS rods and binding wire) |
| 9 | Reinforced cement concrete 1:1½:3 (One cement, one and half sand and three stone jelly) using 20 mm gauge hard granite broken stone jelly for all reinforced cement concrete works with vibratting charges excluding cost of reinforcement grill and fabricating charges, centering and shuttering but including laying, vibrating with mechanical vibrator, finishing, curing, etc.complete as per standard specification. |
| 10 | Plastering with Cement Mortar 1:3 (One Cement and Three Sand) 10 mm thickincluding finishing, curing,etc., complete in all floors complying with standard specification and as directed by the departmental officers. |
| 11 | Plastering with Cement Mortar 1:5 (One cement and Five sand), 12 mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 12 | Plastering with Cement Mortar 1:4 (One cement and Five sand), 20 mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 13 | Paving the floor with Vitrified Marbonite tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3(one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Municipal Engineer before use on work |
| 14 | Weathering course concrete using best quality broken brick jelly of size 20mm uniform gauge in pure slaked lime the proportion of brick jelly to lime being 32:12-1/2 by volume and laid over the RCC roof slab in a single layer and consolidated to the required finished thickness by beating the concrete with wooden, beaters of approved pattern keeping the surface constantly wet by sprinkling jaggery and lime water etc. complete complying with standard specification. |
| 15 | White washing two coats using freshly burnt shell lime white in colour in all floors, including cost of lime blue powder fevical type gum brushes, and scaffolding charges etc. complete complying with standard specification. |
| 16 | Painting 2 coats with approved cement paint over cement plastered wall surface, ceiling and other new surface and including cleaning, preparing the surface and curing etc., complete. |
| 17 | Painting two coats with ready mixed Plastic emusion of first qulity paint two coat and of approved colour over priming coat including through scrapping clean removal of dirt and , preparing the surface and curing etc., complete and including necessary plaster of paris ,Putty wherever required as per standard specification |
| 18 | Painting two coats with ready mixed Enemal paint over one coat of enemalfirst qulity paint for New iron work and of approved colour over priming coat including through scrapping clean removal of dirt and , preparing the surface and curing etc., complete and including necessary plaster of paris ,Putty wherever required as per standard specification |
| 19 | Supplying andfixingofpush and pull type Roliing shutter confirming to IS 6248/1979 and as amended from time to time. With ISI make of approved size and section using 18 gauge G.I.sheet.The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of Hood covers , transportation charges etc., and as directed by Engineer incharge. |
| 20 | Supplying and fixing of M.S. Sheet window using 18 gauge M.S.sheetwith M.S.angle ofsize40mmx40mmx6mm andM.S. flat 25mmx6mm and M.S. squars bars includingcutting, welding, fixing in position cost and conveyance of all materialsto site and all materials to site and all labour charges etc., complete as per standard specifications. |
| 21 | Supplying and fixing steel door double leaf made outof 18 guage M.S. sheet outer frame of 40mmx 40mmx6mm \"L\" angle inner frame of 30mmx30mmx5mm \"L\" angle cross stiffener M.S. flat 25mmx6mm with aldrop 1 No, tower bolts 4 Nos. Two handle and six hold fast complete welded and revitted and painted one coat of red oxide paint including cost and conveyance of all materials and labour etc., complete. |
| 22 | Supply and fixing of Steel glazed ventilator Of size 0.45mx0.60m including cost and conveyence of all materials to site etc complete as per standard specification. |
| 23 | Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC.unsheathed Cu. Conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A F.T. switch with painting of suitable Colourfor open PVC light point / fan point (For electronic regulator) (6points per coil) SD 20 |
| 24 | Supply and fixing of 3 Nos. 5Amps (3 Pin and 2 Pin) combined flush type wall socket with control switches concealed in suitable TW Box covered with Hylem sheet in flush with wall with earth connection (For Computer Plug Socket) SD 139 |
| 25 | Supply and fixing of 5A / 15A 3 pin Combined flush type wall socket with 15A flush type switch on suitable TW Box AS per SD No.136 |