1 | Name of the articles with specifications |
2 | Digital multi-programmable pacemaker with lifetime warranty with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: single chamber: VVI/AAI. With =6F compatible passive-fixation tined lead & lead introducer. |
3 | Digital multi-programmable pacemaker with lifetime warranty with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: single chamber: VVI/AAI. With =6F compatible active-fixation screw-in lead & lead introducer. |
4 | Digital multi-programmable pacemaker pulse generator. Mode: single chamber: VVI/AAI. Pulse generator compatible with above leads (Sl. No. 1 & 2) |
5 | Digital multi-programmable pacemaker with lifetime warranty, 1.5 Tesla MRI compatible with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: single chamber: VVI/AAI. With =6F compatible passive-fixation tined lead & lead introducer. |
6 | Digital multi-programmable pacemaker with lifetime warranty, 1.5 Tesla MRI compatible with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: single chamber: VVI/AAI. With =6F compatible active-fixation screw in lead & lead introducer. |
7 | Digital multi-programmable pacemaker pulse generator, 1.5 Tesla MRI compatible. Mode: single chamber: VVI/AAI. Pulse generator compatible with above leads (Sl. No. 4 & 5) |
8 | Digital multi-programmable pacemaker with lifetime warranty, 3 Tesla MRI compatible with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: single chamber: VVI/AAI. With =6F compatible passive-fixation tined lead & lead introducer. |
9 | Digital multi-programmable pacemaker with lifetime warranty, 3 Tesla MRI compatible with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: single chamber: VVI/AAI. With =6F compatible active-fixation screw in lead & lead introducer. |
10 | Digital multi-programmable pacemaker pulse generator, 3 Tesla MRI compatible. Mode: single chamber: VVI/AAI. Pulse generator compatible with above leads (Sl. No. 7 & 8) |
11 | Digital multi-programmable pacemaker with lifetime warranty, 1.5 Tesla MRI compatible with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: single chamber: VVIR/AAIR. With dynamic adjustment of pacing output and proven longevity of >10 years with 100% pacing of RA/RV. Digital high sampling rate of P/R wave and automated ventricular rate stabilization during AF. With =6F compatible passive-fixation tined lead or screw in lead & lead introducer. |
12 | Pulse generator only for serial number 10. |
13 | Digital multi-programmable pacemaker with lifetime warranty, full body 3 Tesla MRI compatible with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: single chamber: VVIR/AAIR. With dynamic adjustment of pacing output and proven longevity of >10 years with 100% pacing of RA/RV. Digital high sampling rate of P/R wave and automated ventricular rate stabilization during AF. With =6F compatible passive-fixation tined lead or screw in lead & lead introducer. |
14 | Pulse generator only for serial number 12. |
15 | Digital multi-programmable pacemaker with lifetime warranty Mode: Dual chamber VDD (with separate atrial and ventricular leads). With dynamic adjustment of pacing output and proven longevity of >10 years with 100% pacing of RA/RV. With advanced features like automatic AV search, to minimize RV pacing. With =6F compatible passive-fixation tined leads or screw in leads & lead introducers. |
16 | Pulse generator only for serial number 14. |
17 | Digital multi-programmable pacemaker with lifetime warranty Mode: Dual chamber VDD (with separate atrial and ventricular leads) with 1.5 Tesla MRI compatible. With =6F compatible passive-fixation tined leads or screw in leads & lead introducers. |
18 | Pulse generator only for serial number 16. |
19 | Digital multi-programmable pacemaker with lifetime warranty Mode: Dual chamber VDD (with separate atrial and ventricular leads) with full body 3 Tesla MRI compatible. With =6F compatible passive-fixation tined leads or screw in leads & lead introducers. |
20 | Pulse generator only for serial number 18. |
21 | Digital multi-programmable pacemaker with lifetime warranty with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: Dual chamber: DDD. With =6F compatible passive-fixation tined leads or screw in leads & lead introducers. |
22 | Pulse generator only for serial number 20. |
23 | Digital multi-programmable pacemaker with lifetime warranty, 1.5 Tesla MRI compatible with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: Dual chamber: DDD. With =6F compatible passive-fixation tined leads or screw in leads & lead introducers. |
24 | Pulse generator only for serial number 22. |
25 | Digital multi-programmable pacemaker with lifetime warranty, full body 3 Tesla MRI compatible with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: Dual chamber: DDD. With =6F compatible passive-fixation tined leads or screw in leads & lead introducers. |
26 | Pulse generator only for serial number 24. |
27 | Digital multi-programmable pacemaker with lifetime warranty with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: Dual chamber: DDDR. With features of automatic threshold check, auto adjusting of AV delay (extendable upto 400 ms), and automatic intrinsic activity search. With dynamic adjustment of pacing output and proven longevity of >10 years with 100% pacing of RA & RV and algorithm for neurocardiogenic syncope. With =6F compatible passive-fixation tined leads or screw in leads & lead introducers. |
28 | Pulse generator only for serial number 26. |
29 | Digital multi-programmable pacemaker with lifetime warranty, 1.5 Tesla MRI compatible with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: Dual chamber: DDDR. With features of automatic threshold check, auto adjusting of AV delay (extendable upto 400 ms), and automatic intrinsic activity search. With dynamic adjustment of pacing output and proven longevity of >10 years with 100% pacing of RA & RV and algorithm for neurocardiogenic syncope. With =6F compatible passive-fixation tined leads or screw in leads & lead introducers. |
30 | Pulse generator only for serial number 28. |
31 | Digital multi-programmable pacemaker with lifetime warranty, full body 3 Tesla MRI compatible with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: Dual chamber: DDDR. With features of automatic threshold check, auto adjusting of AV delay (extendable upto 400 ms), and automatic intrinsic activity search. With dynamic adjustment of pacing output and proven longevity of >10 years with 100% pacing of RA & RV and algorithm for neurocardiogenic syncope. With =6F compatible passive-fixation tined leads or screw in leads & lead introducers. |
32 | Pulse generator only for serial number 30. |
33 | Biventricular cardiac resynchronization (CRT-P) device with bi-polar LV lead. With =4 vector for pacing from LV lead, having dedicated subselect catheter for cannulation of selective coronary sinus branch, having both peel-away and slittable LV lead introducer sheath. Device with all leads (passive tined or active screwing) and introducers. |
34 | Pulse generator for serial no. 32 (Biventricular cardiac resynchronization (CRT-P) device with bi-polar LV lead). |
35 | Biventricular cardiac resynchronization (CRT-P) device with bipolar LV lead, 1.5 Tesla MRI compatible. With =4 vector for pacing from LV lead, having dedicated subselect catheter for cannulation of selective coronary sinus branch, having both peel-away and slittable LV lead introducer sheath. Device with all leads (passive tined or active screwing) and introducers. |
36 | Pulse generator for serial no. 34 (Biventricular cardiac resynchronization (CRT-P) device with bi-polar LV lead, 1.5 T MRI compatible). |
37 | Biventricular cardiac resynchronization (CRT-P) device with bipolar LV lead, full body 3 Tesla MRI compatible. With =4 vector for pacing from LV lead, having dedicated subselect catheter for cannulation of selective coronary sinus branch, having both peel-away and slittable LV lead introducer sheath. Device with all leads (passive tined or active screwing) and introducers. |
38 | Pulse generator for serial no. 36 (Biventricular cardiac resynchronization (CRT-P) device with bi-polar LV lead, 3 T MRI compatible). |
39 | Biventricular cardiac resynchronization (CRT-P) device with Quadripolar LV lead. With =4 vector for pacing from LV lead, having dedicated subselect catheter for cannulation of selective coronary sinus branch, having both peel-away and slittable LV lead introducer sheath. Device with all leads (passive tined or active screwing) and introducers. |
40 | Pulse generator for serial no. 38 (Biventricular cardiac resynchronization (CRT-P) device with Quadripolar LV lead). |
41 | Biventricular cardiac resynchronization (CRT-P) device with Quadripolar LV lead, 1.5 Tesla MRI compatible. With =4 vector for pacing from LV lead, having dedicated subselect catheter for cannulation of selective coronary sinus branch, having both peel-away and slittable LV lead introducer sheath. Device with all leads (passive tined or active screwing) and introducers. |
42 | Pulse generator for serial no. 40 (Biventricular cardiac resynchronization (CRT-P) device with Quadripolar LV lead, 1.5 T MRI compatible). |
43 | Biventricular cardiac resynchronization (CRT-P) device with Quadripolar LV lead, full body 3 Tesla MRI compatible. With =4 vector for pacing from LV lead, having dedicated subselect catheter for cannulation of selective coronary sinus branch, having both peel-away and slittable LV lead introducer sheath. Device with all leads (passive tined or active screwing) and introducers. |
44 | Pulse generator for serial no. 42 (Biventricular cardiac resynchronization (CRT-P) device with Quadripolar LV lead, 3 T MRI compatible). |
45 | Biventricular cardiac resynchronization (CRT-P) device with epicardial LV lead. Device with all leads (passive tined or active screwing) and introducers. |
46 | Pulse generator for serial no. 44 (Biventricular cardiac resynchronization (CRT-P) device with epicardial LV lead). |
47 | Biventricular cardiac resynchronization (CRT-P) device with epicardial LV lead, 1.5 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers. |
48 | Pulse generator for serial no. 46 (Biventricular cardiac resynchronization (CRT-P) device with epicardial LV lead, 1.5 T MRI compatible). |
49 | Biventricular cardiac resynchronization (CRT-P) device with epicardial LV lead, full body 3 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers. |
50 | Pulse generator for serial no. 48 (Biventricular cardiac resynchronization (CRT-P) device with epicardial LV lead, 3 T MRI compatible). |
51 | Combo device (CRT-D) with bipolar LV lead. Device with all leads (passive tined or active screwing) and introducers. |
52 | Pulse generator for serial no. 50 (Combo device (CRT-D) with bipolar LV lead.) |
53 | Combo device (CRT-D) with bipolar LV lead. 1.5 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers. |
54 | Pulse generator for serial no. 52 (Combo device (CRT-D) with bipolar LV lead. 1.5 Tesla MRI compatible.) |
55 | Combo device (CRT-D) with bipolar LV lead. Full body 3 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers. |
56 | Pulse generator for serial no. 54 (Combo device (CRT-D) with bipolar LV lead. 3 Tesla MRI compatible.) |
57 | Combo device (CRT-D) with bipolar LV lead. Less weight (approx =75±5 gm.) and small volume (approx =30±6 cc), possibility of =5 pacing vectors with bipolar LV lead. Device with all leads (passive tined or active screwing) and introducers. |
58 | Pulse generator for serial no. 56. |
59 | Combo device (CRT-D) with bipolar LV lead, 1.5 Tesla MRI compatible. Less weight (approx =75±5 gm.) and small volume (approx =30±6 cc), possibility of =5 pacing vectors with bipolar LV lead. Device with all leads (passive tined or active screwing) and introducers. |
60 | Pulse generator for serial no. 58 |
61 | Combo device (CRT-D) with bipolar LV lead, full body 3 Tesla MRI compatible. Less weight (approx =75±5 gm.) and small volume (approx =30±6 cc), possibility of =5 pacing vectors with bipolar LV lead. Device with all leads (passive tined or active screwing) and introducers. |
62 | Pulse generator for serial no. 60 |
63 | Combo device (CRT-D) with Quadripolar LV lead. Device with all leads (passive tined or active screwing) and introducers. |
64 | Pulse generator for serial no. 62 (Combo device (CRT-D) with Quadripolar LV lead.) |
65 | Combo device (CRT-D) with Quadripolar LV lead. 1.5 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers. |
66 | Pulse generator for serial no. 64 (Combo device (CRT-D) with Quadripolar LV lead. 1.5 Tesla MRI compatible.) |
67 | Combo device (CRT-D) with Quadripolar LV lead. Full body 3 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers. |
68 | Pulse generator for serial no. 66 (Combo device (CRT-D) with Quadripolar LV lead. 3 Tesla MRI compatible.) |
69 | Combo device (CRT-D) with Quadripolar LV lead. Less weight (approx =75±5 gm.) and small volume (approx =30±6 cc), possibility of =15 pacing vectors with the Quadripolar LV lead. Device with all leads (passive tined or active screwing) and introducers. |
70 | Pulse generator for serial no. 68 |
71 | Combo device (CRT-D) with Quadripolar LV lead, 1.5 Tesla MRI compatible. Less weight (approx =75±5 gm.) and small volume (approx =30±6 cc), possibility of =15 pacing vectors with the Quadripolar LV lead. Device with all leads (passive tined or active screwing) and introducers. |
72 | Pulse generator for serial no. 70 |
73 | Combo device (CRT-D) with Quadripolar LV lead, full body 3 Tesla MRI compatible. Less weight (approx =75±5 gm.) and small volume (approx =30±6 cc), possibility of =15 pacing vectors with the Quadripolar LV lead. Device with all leads (passive tined or active screwing) and introducers. |
74 | Pulse generator for serial no. 72 |
75 | Combo device (CRT-D) with bipolar LV lead, with DF-4 connector of RV lead. Less weight (approx =75±5 gm.) and small volume (approx =30±6 cc), possibility of =5 pacing vectors with bipolar LV lead. Device with all leads (passive tined or active screwing) and introducers. |
76 | Pulse generator for serial no. 74 |
77 | Combo device (CRT-D) with bipolar LV lead, DF-4 connector of RV lead, 1.5 Tesla MRI compatible. Less weight (approx =75±5 gm.) and small volume (approx =30±6 cc), possibility of =5 pacing vectors with bipolar LV lead. Device with all leads (passive tined or active screwing) and introducers. |
78 | Pulse generator for serial no. 76 |
79 | Combo device (CRT-D) with bipolar LV lead, DF-4 connector of RV lead, full body 3 Tesla MRI compatible. Less weight (approx =75±5 gm.) and small volume (approx =30±6 cc), possibility of =5 pacing vectors with bipolar LV lead. Device with all leads (passive tined or active screwing) and introducers. |
80 | Pulse generator for serial no. 78 |
81 | Combo device (CRT-D) with Quadripolar LV lead, DF-4 connector of RV lead. Less weight (approx =75±5 gm.) and small volume (approx =30±6 cc), with possibility of =15 pacing vectors with Quadripolar LV lead. Device with all leads (passive tined or active screwing) and introducers. |
82 | Pulse generator for serial no. 80 |
83 | Combo device (CRT-D) with Quadripolar LV lead, DF-4 connector of RV lead, 1.5 Tesla MRI compatible. Less weight (approx =75±5 gm.) and small volume (approx =30±6 cc), with possibility of =15 pacing vectors with Quadripolar LV lead. Device with all leads (passive tined or active screwing) and introducers. |
84 | Pulse generator for serial no. 82 |
85 | Combo device (CRT-D) with Quadripolar LV lead, DF-4 connector of RV lead, full body 3T MRI compatible. Less weight (approx =75±5 gm.) and small volume (approx =30±6 cc), with possibility of =15 pacing vectors with Quadripolar LV lead. Device with all leads (passive tined or active screwing) and introducers. |
86 | Pulse generator for serial no. 84 |
87 | Combo device (CRT-D) with epicardial LV lead. Device with all leads (passive tined or active screwing) and introducers. |
88 | Pulse generator for serial no. 86 |
89 | Combo device (CRT-D) with epicardial LV lead, 1.5 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers. |
90 | Pulse generator for serial no. 88 |
91 | Combo device (CRT-D) with epicardial LV lead, full body 3T MRI compatible. Device with all leads (passive tined or active screwing) and introducers. |
92 | Pulse generator for serial no. 90 |
93 | Implantable cardioverter defibrillator: Single chamber. Device with lead (passive tined or active screwing) |
94 | Pulse generator for serial no. 92 (Implantable cardioverter defibrillator: Single chamber.) |
95 | Implantable cardioverter defibrillator: Single chamber, 1.5 Tesla MRI compatible. Device with lead (passive tined or active screwing) |
96 | Pulse generator for serial no. 94 (Implantable cardioverter defibrillator: Single chamber, 1.5 T MRI compatible.) |
97 | Implantable cardioverter defibrillator: Single chamber, full body 3T MRI compatible. Device with lead (passive tined or active screwing) |
98 | Pulse generator for serial no. 96 (Implantable cardioverter defibrillator: Single chamber, 3 T MRI compatible.) |
99 | Implantable cardioverter defibrillator: Single chamber with DF-4 header. Device with lead (passive tined or active screwing) and introducers. |
100 | Pulse generator for serial no. 98 (Implantable cardioverter defibrillator: Single chamber with DF-4 header) |
101 | Implantable cardioverter defibrillator: Single chamber with DF-4 header, 1.5 Tesla MRI compatible. Device with lead (passive tined or active screwing) and introducers. |
102 | Pulse generator for serial no. 100 (Implantable cardioverter defibrillator: Single chamber with DF-4 header, 1.5 T MRI compatible.) |
103 | Implantable cardioverter defibrillator: Single chamber with DF-4 header, full body 3T MRI compatible. Device with lead (passive tined or active screwing) and introducers. |
104 | Pulse generator for serial no. 102 (Implantable cardioverter defibrillator: Single chamber with DF-4 header, 3 T MRI compatible.) |
105 | Implantable cardioverter defibrillator: Dual chamber. Device with all leads (passive tined or active screwing) and introducers. |
106 | Pulse generator for serial no. 104 (Implantable cardioverter defibrillator: Dual chamber.) |
107 | Implantable cardioverter defibrillator: Dual chamber, 1.5 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers. |
108 | Pulse generator for serial no. 106 (Implantable cardioverter defibrillator: Dual chamber, 1.5 T MRI compatible.) |
109 | Implantable cardioverter defibrillator: Dual chamber, full body 3 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers. |
110 | Pulse generator for serial no. 108 (Implantable cardioverter defibrillator: Dual chamber, 3 T MRI compatible.) |
111 | Implantable cardioverter defibrillator: Dual chamber. Less weight (approx =60±5 gm.) and small volume (approx =25±5 cc) with advanced features of automatic AV search, adjustable AV delay etc. Device with all leads (passive tined or active screwing) and introducers. |
112 | Pulse generator for serial no. 110 |
113 | Implantable cardioverter defibrillator: Dual chamber, 1.5 Tesla MRI compatible. Less weight (approx =60±5 gm.) and small volume (approx =25±5 cc) with advanced features of automatic AV search, adjustable AV delay etc. Device with all leads (passive tined or active screwing) and introducers. |
114 | Pulse generator for serial no. 112 |
115 | Implantable cardioverter defibrillator: Dual chamber, full body 3 Tesla MRI compatible. Less weight (approx =60±5 gm.) and small volume (approx =25±5 cc) with advanced features of automatic AV search, adjustable AV delay etc. Device with all leads (passive tined or active screwing) and introducers. |
116 | Pulse generator for serial no. 114 |
117 | Implantable cardioverter defibrillator: Dual chamber with DF-4 header. Less weight (approx =60±5 gm.) and small volume (approx =25±5 cc) with advanced features of automatic AV search, adjustable AV delay etc. Device with all leads (passive tined or active screwing) and introducers. |
118 | Pulse generator for serial no. 116 |
119 | Implantable cardioverter defibrillator: Dual chamber with DF-4 header, with 1.5 Tesla MRI compatible. Less weight (approx =60±5 gm.) and small volume (approx =25±5 cc) with advanced features of automatic AV search, adjustable AV delay etc. Device with all leads (passive tined or active screwing) and introducers. |
120 | Pulse generator for serial no. 118 |
121 | Implantable cardioverter defibrillator: Dual chamber with DF-4 header, with full body 3 Tesla MRI compatible. Less weight (approx =60±5 gm.) and small volume (approx =25±5 cc) with advanced features of automatic AV search, adjustable AV delay etc. Device with all leads (passive tined or active screwing) and introducers. |
122 | Pulse generator for serial no. 120 |
123 | Subcutaneous ICD. Device with lead and all accessories for implantation |
124 | Pulse generator for serial no. 122 |
125 | MRI compatible subcutaneous ICD. Device with lead and all accessories for implantation |
126 | Pulse generator for serial no. 124 |
127 | Permanent pacing lead (ventricular/atrial endocardial bipolar, passive fixation with tines), steroid eluting, IS-1 header with the introducer sheath and puncture set (PLI). |
128 | Permanent pacing lead (ventricular/atrial endocardial bipolar, passive fixation with tines), steroid eluting, IS-1 header with the introducer sheath and puncture set (PLI). |
129 | 1.5 Tesla MRI compatible permanent pacing lead (ventricular/atrial endocardial bipolar, passive fixation with tines), steroid eluting, IS-1 header with the introducer sheath and puncture set (PLI). |
130 | 3 Tesla full body MRI compatible permanent pacing lead (ventricular/atrial endocardial bipolar, passive fixation with tines), steroid eluting, IS-1 header with the introducer sheath and puncture set (PLI). |
131 | 3 Tesla full body MRI compatible permanent pacing lead (ventricular/atrial endocardial bipolar, passive fixation with tines), steroid eluting, IS-1 header with the introducer sheath and puncture set (PLI). |
132 | Permanent pacing lead (ventricular/atrial endocardial bipolar, active fixation steroid eluting screw in lead) with IS-1 header with the introducer sheath and puncture set (PLI). |
133 | 1.5 Tesla MRI compatible permanent pacing lead (ventricular/atrial endocardial bipolar, active fixation steroid eluting screw in lead) with IS-1 header with the introducer sheath and puncture set (PLI). |
134 | 3 Tesla full body MRI compatible permanent pacing lead (ventricular/atrial endocardial bipolar, active fixation steroid eluting screw in lead) with IS-1 header with the introducer sheath and puncture set (PLI). |
135 | 3 Tesla full body MRI compatible permanent pacing lead (ventricular/atrial endocardial bipolar, active fixation steroid eluting screw in lead) with IS-1 header with the introducer sheath and puncture set (PLI). |
136 | Unipolar, MRI compatible, epicardial permanent screw-in pacing lead, steroid eluting, IS-1 header with the deploying kit and introducer set. |
137 | Unipolar, MRI compatible, epicardial permanent screw-in pacing lead, steroid eluting, IS-1 header with the deploying kit and introducer set. |
138 | Bipolar, MRI compatible, epicardial permanent screw-in pacing lead, steroid eluting, IS-1 header with the deploying kit. |
139 | Bipolar, MRI compatible, epicardial permanent screw-in pacing lead, steroid eluting, IS-1 header with the deploying kit. |
140 | MRI compatible short (45±3 cm) endocardial bipolar pacing lead with introducer sheath and puncture set (PLI). |
141 | Only introducer kit for endocardial RA/RV/ICD leads (without leads), 6F, 7F, 8F. |
142 | Permanent defibrillation lead, bipolar, endocardial steroid eluting tipped, DF-1 header, with the introducer kit and puncture set (PLI). Tined end |
143 | Permanent defibrillation lead, bipolar, endocardial steroid eluting tipped, DF-1 header, with the introducer kit and puncture set (PLI). Screw in lead |
144 | Permanent defibrillation lead, bipolar, endocardial steroid eluting leads, DF-1 header, with the introducer sheath and puncture set (PLI). 1.5 Tesla full body MRI compatible. Tined lead |
145 | Permanent defibrillation lead, bipolar, endocardial steroid eluting leads, DF-1 header, with the introducer sheath and puncture set (PLI). 1.5 Tesla full body MRI compatible. Screw lead |
146 | Permanent defibrillation lead, bipolar, endocardial steroid eluting leads, DF-1 header, with the introducer sheath and puncture set (PLI). 3 Tesla full body MRI compatible. Tined lead |
147 | Permanent defibrillation lead, bipolar, endocardial steroid eluting leads, DF-1 header, with the introducer sheath and puncture set (PLI). 3 Tesla full body MRI compatible. Screw lead |
148 | Permanent defibrillation lead, bipolar, endocardial steroid eluting tipped, with DF-4 header, with the introducer kit and puncture set (PLI). Tined end |
149 | Permanent defibrillation lead, bipolar, endocardial steroid eluting tipped, with DF-4 header, with the introducer kit and puncture set (PLI). Screw end |
150 | Permanent defibrillation lead, bipolar, endocardial steroid eluting tipped, DF-4 header, with the introducer kit and puncture set (PLI), 1.5 Tesla MRI compatible. Tined end |
151 | Permanent defibrillation lead, bipolar, endocardial steroid eluting tipped, DF-4 header, with the introducer kit and puncture set (PLI), 1.5 Tesla MRI compatible. Screw end |
152 | Permanent defibrillation lead, bipolar, endocardial steroid eluting tipped, DF-4 header, with the introducer kit and puncture set (PLI), full body 3 Tesla MRI compatible. Tined end |
153 | Permanent defibrillation lead, bipolar, endocardial steroid eluting tipped, DF-4 header, with the introducer kit and puncture set (PLI), full body 3 Tesla MRI compatible. Screw end |
154 | Bipolar endocardial LV lead with introducer kit and puncture set (PLI). |
155 | Bipolar endocardial LV lead with introducer kit and puncture set (PLI), 1.5 Tesla MRI compatible. |
156 | Bipolar endocardial LV lead with introducer kit and puncture set (PLI), full body 3 Tesla MRI compatible. |
157 | Quadripolar endocardial LV lead with introducer kit and puncture set (PLI). |
158 | Quadripolar endocardial LV lead with introducer kit and puncture set (PLI), 1.5 Tesla MRI compatible. |
159 | Quadripolar endocardial LV lead with introducer kit and puncture set (PLI), full body 3 Tesla MRI compatible. |
160 | Quadripolar endocardial LV lead for multisite pacing with introducer kit and puncture set (PLI), full body 3 Tesla MRI compatible. |
161 | CS cannulation kit only (without the LV lead) with all accessories like sheath, puncture needle, syringe, 0.035” long guidewire. |
162 | External event recording of upto one week of arrhythmic events, portable, easy to operate with 1/3 lead system and easy operation by patient/relatives at home. |
163 | Patch type External event recorder, disposable, wireless, easy to use smart biosensor, shower-proof for recording upto one week of arrhythmic events, and easy operation by patient/relatives at home. |
164 | Implantable event/loop recorder for recording of arrhythmic events for prolong period of upto 2 years. |
165 | Digital multi-programmable pacemaker with features of automatic detection of MRI and conditioning whenever the device/patient comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over. Mode: VVIR Device with lead and all accessories |
166 | Pulse generator for serial no. 159 |
167 | Digital multi-programmable pacemaker with features of automatic detection of MRI and conditioning whenever the device/patient comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over. Mode: DDDR Device with leads and all accessories |
168 | Pulse generator for serial no. 161 |
169 | CRT-D with features of automatic detection of MRI and conditioning whenever the device/patient comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over. Mode: CRT-D with bipolar LV lead Device with leads and all accessories |
170 | Pulse generator for serial no. 163 |
171 | CRT-D with features of automatic detection of MRI and conditioning whenever the device comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over. Mode: CRT-D with Quadripolar LV lead Device with leads and all accessories |
172 | Pulse generator for serial no. 165 |
173 | Single chamber ICD with features of automatic detection of MRI and conditioning whenever the device comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over. Mode: ICD (single chamber) Device with leads and all accessories |
174 | Pulse generator for serial no. 167 |
175 | Dual chamber ICD with features of automatic detection of MRI and conditioning whenever the device comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over. Mode: ICD (Dual chamber) Device with leads and all accessories |
176 | Pulse generator for serial no. 169 |
177 | Combo device (CRT-D) with Quadripolar LV lead having features of multi-site pacing from LV lead. Device with all leads (passive tined or active screwing) and introducers. |
178 | Pulse generator for serial no. 171 |
179 | Combo device (CRT-D) with Quadripolar LV lead having features of multi-site pacing from LV lead, 1.5 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers. |
180 | Pulse generator for serial no. 173 |
181 | Combo device (CRT-D) with Quadripolar LV lead having features of multi-site pacing from LV lead, full body 3 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers. |
182 | Pulse generator for serial no. 175 |
183 | Combo device (CRT-D) with Quadripolar LV lead having features of multi-site pacing from LV lead. DF-4 RV lead. Device with all leads (passive tined or active screwing) and introducers. |
184 | Pulse generator for serial no. 177 |
185 | Combo device (CRT-D) with Quadripolar LV lead having features of multi-site pacing from LV lead, DF-4 RV lead, 1.5 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers. |
186 | Pulse generator for serial no. 179 |
187 | Combo device (CRT-D) with Quadripolar LV lead having features of multi-site pacing from LV lead, DF-4 RV lead, 3 Tesla full body MRI compatible. Less weight (approx =75±5 gm.) and small volume (approx =30±6 cc). Device with all leads (passive tined or active screwing) and introducers. |
188 | Pulse generator for serial no. 181 |
189 | Digital multi-programmable pacemaker with limited warranty for 10 years. Mode: single chamber: VVI/AAI. With dynamic adjustment of pacing output. Digital high sampling rate of P/R wave and automated ventricular rate stabilization during AF and with Automatic capture facility for rescue pacing and automatic lead polarity switch. With =6F compatible passive-fixation tined lead or screw in lead & lead introducer. |
190 | Digital multi-programmable pacemaker with limited warranty for 10 years. Mode: single chamber: VVI/AAI. With dynamic adjustment of pacing output. Digital high sampling rate of P/R wave and automated ventricular rate stabilization during AF. a. With 6F compatible passivefixation tined lead or screw in lead & lead introducer. |
191 | Pulse generator for serial no. 183.1 |
192 | Pulse generator for serial no. 183.2 |
193 | Digital multi-programmable pacemaker with limited warranty for 10 years, 1.5 Tesla MRI compatible. Mode: single chamber: VVI/AAI. With dynamic adjustment of pacing output. Digital high sampling rate of P/R wave and automated ventricular rate stabilization during AF and with Automatic capture facility for rescue pacing and automatic lead polarity switch. With =6F compatible passive-fixation tined lead or screw in lead & lead introducer. |
194 | Pulse generator for serial no. 185 |
195 | Digital multi-programmable pacemaker with limited warranty for 10 years, full body 3 Tesla MRI compatible. Mode: single chamber: VVI/AAI. With dynamic adjustment of pacing output. Digital high sampling rate of P/R wave and automated ventricular rate stabilization during AF and with Automatic capture facility for rescue pacing and automatic lead polarity switch. With =6F compatible passive-fixation tined lead or screw in lead & lead introducer. |
196 | Pulse generator for serial no. 187 |
197 | Digital multi-programmable pacemaker with limited warranty for 10 years. Mode: single chamber: VVIR/AAIR. With dynamic adjustment of pacing output. Digital high sampling rate of P/R wave and automated ventricular rate stabilization during AF and with Automatic capture facility for rescue pacing and automatic lead polarity switch. With =6F compatible passive-fixation tined lead or screw in lead & lead introducer. |
198 | Pulse generator for serial no. 189 |
199 | Digital multi-programmable pacemaker with limited warranty for 10 years, 1.5 Tesla MRI compatible. Mode: single chamber: VVIR/AAIR. With dynamic adjustment of pacing output. Digital high sampling rate of P/R wave and automated ventricular rate stabilization during AF and with Automatic capture facility for rescue pacing and automatic lead polarity switch. With =6F compatible passive-fixation tined lead or screw in lead & lead introducer. (Golden parameters: (i) =6F sheath compatible lead, (ii) automated ventricular rate stabilization in AF, (iii) 1.5 T MRI compatibility, (iv) Automatic capture) |
200 | Pulse generator for serial no. 191 |
201 | Digital multi-programmable pacemaker with limited warranty for 10 years, full body 3 Tesla MRI compatible. Mode: single chamber: VVIR/AAIR. With dynamic adjustment of pacing output. Digital high sampling rate of P/R wave and automated ventricular rate stabilization during AFand with Automatic capture facility for rescue pacing and automatic lead polarity switch. With =6F compatible passive-fixation tined lead or screw in lead & lead introducer. |
202 | Pulse generator for serial no. 193 |
203 | Digital multi-programmable pacemaker with lifetime warranty. Mode: Dual chamber: DDDR. With features of automatic threshold check, auto adjusting of AV delay (extendable upto 400 ms), automatic intrinsic activity search, and ATP. With dynamic adjustment of pacing output and proven longevity of >10 years with 100% pacing of RA & RV and with Automatic capture facility for rescue pacing and automatic lead polarity switch. With =6F compatible passive-fixation tined leads or screw in leads & lead introducers. |
204 | Digital multi - programmable pacemaker with lifetime warranty. Mode: Dual chamber: DDDR with features of automatic threshold check, auto adjusting of AV delay (extendable upto 400ms), and automatic intrinsic activity search. With dynamic adjustment of pacing output ad proven longevity of >10 years with 100% pacing of RA & RV. a. With 6F compatible passivefixation tined leads or screw in leads and lead introducers. |
205 | Pulse generator for serial no. 195A |
206 | Pulse generator for serial no. 195B |
207 | Digital multi-programmable pacemaker with lifetime warranty. Mode: Dual chamber: DDDR. With features of automatic threshold check, auto adjusting of AV delay (extendable upto 400 ms), automatic intrinsic activity search, and ATP. With dynamic adjustment of pacing output and proven longevity of >10 years with 100% pacing of RA & RV. 1.5 Tesla MRI compatible and with Automatic capture facility for rescue pacing and automatic lead polarity switch. With =6F compatible passive-fixation tined leads or screw in leads & lead introducers. |
208 | Pulse generator for serial no. 197 |
209 | Digital multi-programmable pacemaker with lifetime warranty. Mode: Dual chamber: DDDR. With features of automatic threshold check, auto adjusting of AV delay (extendable upto 400 ms), automatic intrinsic activity search, and ATP. With dynamic adjustment of pacing output and proven longevity of >10 years with 100% pacing of RA & RV and with Automatic capture facility for rescue pacing and automatic lead polarity switch. Full body 3 Tesla MRI compatible. With =6F compatible passive-fixation tined leads or screw in leads & lead introducers. |
210 | Digital multi - programmable pacemaker with lifetime warranty, full body 3 Tesla MRI compatible. Mode: Dual chamber: DDDR. With features of automatic threshold check, auto adjusting of AV delay (extendable up to 400ms), and automatic intrinsic activity search. With dynamic adjustment of pacing output and proven longevity of >10 years with 100% pacing of RA & RV. a. With 6F compatible passive fixation tined leads or screw in or active screwing) and introducers. |
211 | Pulse generator for serial no. 199A |
212 | Pulse generator for serial no. 199B |
213 | Digital multi-programmable pacemaker with lifetime warranty with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: Dual chamber: DDDR. With features of automatic threshold check, auto adjusting of AV delay (extendable upto 400 ms), and automatic intrinsic activity search. With dynamic adjustment of pacing output and proven longevity of >10 years with 100% pacing of RA & RV and with closed loop stimulation. With =6F compatible passive-fixation tined leads or screw in leads & lead introducers. |
214 | Pulse generator for serial no.201 |
215 | Digital multi-programmable pacemaker with lifetime warranty with Automatic capture facility for rescue pacing and automatic lead polarity switch. Mode: Dual chamber: DDDR. With features of automatic threshold check, auto adjusting of AV delay (extendable upto 400 ms), and automatic intrinsic activity search. With dynamic adjustment of pacing output and proven longevity of >10 years with 100% pacing of RA & RV and with minute ventilation sensor. With =6F compatible passive-fixation tined leads or screw in leads & lead introducers. |
216 | Pulse generator for serial no.203 |
217 | Implantable cardioverter defibrillator: VDD with single lead. Device with lead (passive tined or active screwing) and introducer set. |
218 | Pulse generator for serial no. 205 |
219 | Implantable cardioverter defibrillator: VDD with single lead, 1.5 Tesla MRI compatible. Device with lead (passive tined or active screwing) and introducer set. |
220 | Pulse generator for serial no. 207 |
221 | Implantable cardioverter defibrillator: VDD with single lead, full body 3 Tesla MRI compatible. Device with lead (passive tined or active screwing) and introducer set. |
222 | Pulse generator for serial no. 209 |
223 | MRI compatible Leadless pacemaker with all accessories for implantation. VVIR type. |
224 | 3 Tesla & / 1.5 Tesla full body MRI conditional Multi-programmable, Quadripolar lead, auto capture management for RA,RV & LV, Automatic atrial anti tachy therapies, Heart failure diagnostics with trans thoracic fluid impedance measurement and rate drop response, multi-site/multipoint pacing CRT-P. |
225 | Pulse generator for serial no. 212 |
226 | 3 Tesla & / 1.5 Tesla full body MRI conditional Multi-programmable, Quadripolar lead, auto capture management for RA,RV & LV, Automatic atrial anti tachy therapies, Heart failure diagnostics with trans thoracic fluid impedance measurement and rate drop response, multi-site/multipoint pacing CRT-D. |
227 | Pulse generator for serial no. 214 |
228 | DDDR pacemaker with rate response, AF diagnostic and heart failure management. |
229 | Pulse generator for serial no. 216 |
230 | 3.0 Tesla DDDR pacemaker with auto rate response, AF diagnostic and heart failure management. |
231 | Pulse generator for serial no. 218 |
232 | His bundle pacing system A) Complete system with leads B) IPG only C) His bundle lead only |
233 | Pulse generator for serial no. 220 |
234 | 3 Tesla MRI compatible His bundle pacing system A) Complete system with leads B) IPG only C) His bundle lead only |
235 | Pulse generator for serial no. 222 |
236 | Adaptor for old pacing lead to IS-I Compatible |
237 | Latex free compression set with soft material for pacemaker/ICD implantation after care. |
238 | Implantable cardioverter defibrillator: Single chamber. With 8 years full warranty plus 2 years warranty on pro-rata basis. Device with lead (passive tined or active screwing) and introducer set. |
239 | Pulse generator for serial no. 226 |
240 | Implantable cardioverter defibrillator: Single chamber, 3 Tesla MRI compatible. With 8 years full warranty plus 2 years warranty on pro-rata basis. Device with lead (passive tined or active screwing) and introducer set. |
241 | Pulse generator for serial no. 228 |
242 | Implantable cardioverter defibrillator: Dual chamber with 5 years full warranty plus 3 years warranty on pro-rata basis. Device with all leads (passive tined or active screwing) and introducers. |
243 | Pulse generator for serial no. 230 |
244 | Implantable cardioverter defibrillator: Dual chamber, 3 Tesla MRI compatible. With 5 years full warranty plus 3 years warranty on pro-rata basis. Device with all leads (passive tined or active screwing) and introducers. |
245 | Pulse generator for serial no. 232 |
246 | Combo device (CRT-D) with Quadripolar LV lead, with 4 years full warranty plus 2 years warranty on pro-rata basis. Device with all leads (passive tined or active screwing) and introducers. |
247 | Pulse generator for serial no. 234 |
248 | Combo device (CRT-D) with Quadripolar LV lead, with 4 years full warranty plus 2 years warranty on pro-rata basis. 3 Tesla MRI compatible. Device with all leads (passive tined or active screwing) and introducers. |
249 | Pulse generator for serial no. 236 |
250 | MRI compatible AV Leadless pacemaker (AV Micra) with all accessories for implantation. |
251 | His Bundle DDDR Pacemaker. (a.)Multi-programmable Dual Chamber Rate Responsive Full Body 3 T MRI Compatible Pacemaker. (b.) Atrial Endocardial Leads both Active and Passive Fixation IS-1 Bipolar and Unipolar as per Clinical Need. (c.) HIS Bundle with Lumen Pacing Lead with Catheter and all accessories (c.) Auto Capture Output Management Software for battery Optimization. (d.) Lead Polarity Switch (e.) With 8 year Warranty Replacement Policy. (f) automatic detection of MRI and conditioning whenever the device/patient comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over. |
252 | Pulse generator for serial no. 239 |
253 | His Bundle DDDR Pacemaker with lifetime warranty. (a.)Multi-programmable Dual Chamber Rate Responsive Full Body 3 Tesla MRI Compatible Pacemaker. (b.) Atrial Endocardial Leads both Active and Passive Fixation IS-1 Bipolar and Unipolar as per Clinical Need. (c.) HIS Bundle with Lumen Pacing Lead with Catheter and all accessories (c.) Auto Capture Output Management Software for battery Optimization. (d.) Lead Polarity Switch (e) automatic detection of MRI and conditioning whenever the device/patient comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over. |
254 | Pulse generator for serial no. 241 |
255 | His Bundle DDDR Pacemaker: Dual Chamber Rate Responsive 3 T Full body MRI compatible Pacemaker with HIS Bundle Lumen Lead and Delivery System with features of automatic detection of MRI and conditioning whenever the device/patient comes to an MRI environment or MR room for MRI and with automatic timeout feature, bringing back the normal settings whenever the set window period is over. (a.) HIS Bundle Screwing Lead with Lumen (b.) With Delivery Catheter. |
256 | Pulse generator for serial no. 243 |