}

Tender For Supply Of Permanent Pacemakers And Devices, delhi-Delhi

Dr. Ram Manohar Lohia Hospital has published Tender For Supply Of Permanent Pacemakers And Devices. Submission Date for this Tender is 27-05-2023. Medical Diagnostic x ray Products Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

37418661
Corrigendum : Tender For Supply Of Permanent Pacemakers And Devices
Tender
Indian
Delhi
Delhi
27-05-2023

Tender Details

Supply Of Permanent Pacemakers And Devices -2 Digital Multi-Programmable Pacemaker With Lifetime Warranty With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.Mode: Single Chamber: Vvi / Aai.With =6F Compatible Passive-Fixation Tined Lead & Lead Introducer. 3 Digital Multi-Programmable Pacemaker With Lifetime Warranty With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.Mode: Single Chamber: Vvi / Aai.With =6F Compatible Active-Fixation Screw-In Lead & Lead Introducer. 4 Digital Multi-Programmable Pacemaker Pulse Generator.Mode: Single Chamber: Vvi / Aai.Pulse Generator Compatible With Above Leads ( Sl. No. 1 & 2 ) 5 Digital Multi-Programmable Pacemaker With Lifetime Warranty, 1.5 Tesla Mri Compatible With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.Mode: Single Chamber: Vvi / Aai.With =6F Compatible Passive-Fixation Tined Lead & Lead Introducer. 6 Digital Multi-Programmable Pacemaker With Lifetime Warranty, 1.5 Tesla Mri Compatible With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.Mode: Single Chamber: Vvi / Aai.With =6F Compatible Active-Fixation Screw In Lead & Lead Introducer. 7 Digital Multi-Programmable Pacemaker Pulse Generator, 1.5 Tesla Mri Compatible.Mode: Single Chamber: Vvi / Aai.Pulse Generator Compatible With Above Leads ( Sl. No. 4 & 5 ) 8 Digital Multi-Programmable Pacemaker With Lifetime Warranty, 3 Tesla Mri Compatible With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.Mode: Single Chamber: Vvi / Aai.With =6F Compatible Passive-Fixation Tined Lead & Lead Introducer. 9 Digital Multi-Programmable Pacemaker With Lifetime Warranty, 3 Tesla Mri Compatible With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.Mode: Single Chamber: Vvi / Aai.With =6F Compatible Active-Fixation Screw In Lead & Lead Introducer. 10 Digital Multi-Programmable Pacemaker Pulse Generator, 3 Tesla Mri Compatible.Mode: Single Chamber: Vvi / Aai.Pulse Generator Compatible With Above Leads ( Sl. No. 7 & 8 ) 11 Digital Multi-Programmable Pacemaker With Lifetime Warranty, 1.5 Tesla Mri Compatible With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.Mode: Single Chamber: Vvir / Aair. With Dynamic Adjustment Of Pacing Output And Proven Longevity Of >10 Years With 100% Pacing Of Ra / Rv. Digital High Sampling Rate Of P / R Wave And Automated Ventricular Rate Stabilization During Af.With =6F Compatible Passive-Fixation Tined Lead Or Screw In Lead & Lead Introducer. 12 Pulse Generator Only For Serial Number 10. 13 Digital Multi-Programmable Pacemaker With Lifetime Warranty, Full Body 3 Tesla Mri Compatible With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.Mode: Single Chamber: Vvir / Aair. With Dynamic Adjustment Of Pacing Output And Proven Longevity Of >10 Years With 100% Pacing Of Ra / Rv. Digital High Sampling Rate Of P / R Wave And Automated Ventricular Rate Stabilization During Af.With =6F Compatible Passive-Fixation Tined Lead Or Screw In Lead & Lead Introducer. 14 Pulse Generator Only For Serial Number 12. 15 Digital Multi-Programmable Pacemaker With Lifetime Warrantymode: Dual Chamber Vdd ( With Separate Atrial And Ventricular Leads ) . With Dynamic Adjustment Of Pacing Output And Proven Longevity Of >10 Years With 100% Pacing Of Ra / Rv. With Advanced Features Like Automatic Av Search, To Minimize Rv Pacing.With =6F Compatible Passive-Fixation Tined Leads Or Screw In Leads & Lead Introducers. 16 Pulse Generator Only For Serial Number 14. 17 Digital Multi-Programmable Pacemaker With Lifetime Warrantymode: Dual Chamber Vdd ( With Separate Atrial And Ventricular Leads ) With 1.5 Tesla Mri Compatible.With =6F Compatible Passive-Fixation Tined Leads Or Screw In Leads & Lead Introducers. 18 Pulse Generator Only For Serial Number 16. 19 Digital Multi-Programmable Pacemaker With Lifetime Warrantymode: Dual Chamber Vdd ( With Separate Atrial And Ventricular Leads ) With Full Body 3 Tesla Mri Compatible.With =6F Compatible Passive-Fixation Tined Leads Or Screw In Leads & Lead Introducers. 20 Pulse Generator Only For Serial Number 18. 21 Digital Multi-Programmable Pacemaker With Lifetime Warranty With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.Mode: Dual Chamber: Ddd.With =6F Compatible Passive-Fixation Tined Leads Or Screw In Leads & Lead Introducers. 22 Pulse Generator Only For Serial Number 20. 23 Digital Multi-Programmable Pacemaker With Lifetime Warranty, 1.5 Tesla Mri Compatible With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.Mode: Dual Chamber: Ddd.With =6F Compatible Passive-Fixation Tined Leads Or Screw In Leads & Lead Introducers. 24 Pulse Generator Only For Serial Number 22. 25 Digital Multi-Programmable Pacemaker With Lifetime Warranty, Full Body 3 Tesla Mri Compatible With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.Mode: Dual Chamber: Ddd.With =6F Compatible Passive-Fixation Tined Leads Or Screw In Leads & Lead Introducers. 26 Pulse Generator Only For Serial Number 24. 27 Digital Multi-Programmable Pacemaker With Lifetime Warranty With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.Mode: Dual Chamber: Dddr. With Features Of Automatic Threshold Check, Auto Adjusting Of Av Delay ( Extendable Upto 400 Ms ) , And Automatic Intrinsic Activity Search. With Dynamic Adjustment Of Pacing Output And Proven Longevity Of >10 Years With 100% Pacing Of Ra & Rv And Algorithm For Neurocardiogenic Syncope.With =6F Compatible Passive-Fixation Tined Leads Or Screw In Leads & Lead Introducers. 28 Pulse Generator Only For Serial Number 26. 29 Digital Multi-Programmable Pacemaker With Lifetime Warranty, 1.5 Tesla Mri Compatible With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.Mode: Dual Chamber: Dddr. With Features Of Automatic Threshold Check, Auto Adjusting Of Av Delay ( Extendable Upto 400 Ms ) , And Automatic Intrinsic Activity Search. With Dynamic Adjustment Of Pacing Output And Proven Longevity Of >10 Years With 100% Pacing Of Ra & Rv And Algorithm For Neurocardiogenic Syncope.With =6F Compatible Passive-Fixation Tined Leads Or Screw In Leads & Lead Introducers. 30 Pulse Generator Only For Serial Number 28. 31 Digital Multi-Programmable Pacemaker With Lifetime Warranty, Full Body 3 Tesla Mri Compatible With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.Mode: Dual Chamber: Dddr. With Features Of Automatic Threshold Check, Auto Adjusting Of Av Delay ( Extendable Upto 400 Ms ) , And Automatic Intrinsic Activity Search. With Dynamic Adjustment Of Pacing Output And Proven Longevity Of >10 Years With 100% Pacing Of Ra & Rv And Algorithm For Neurocardiogenic Syncope.With =6F Compatible Passive-Fixation Tined Leads Or Screw In Leads & Lead Introducers. 32 Pulse Generator Only For Serial Number 30. 33 Biventricular Cardiac Resynchronization ( Crt-P ) Device With Bi-Polar Lv Lead.With =4 Vector For Pacing From Lv Lead, Having Dedicated Subselect Catheter For Cannulation Of Selective Coronary Sinus Branch, Having Both Peel-Away And Slittable Lv Lead Introducer Sheath.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 34 Pulse Generator For Serial No. 32 ( Biventricular Cardiac Resynchronization ( Crt-P ) Device With Bi-Polar Lv Lead ) . 35 Biventricular Cardiac Resynchronization ( Crt-P ) Device With Bipolar Lv Lead, 1.5 Tesla Mri Compatible.With =4 Vector For Pacing From Lv Lead, Having Dedicated Subselect Catheter For Cannulation Of Selective Coronary Sinus Branch, Having Both Peel-Away And Slittable Lv Lead Introducer Sheath.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 36 Pulse Generator For Serial No. 34 ( Biventricular Cardiac Resynchronization ( Crt-P ) Device With Bi-Polar Lv Lead, 1.5 T Mri Compatible ) . 37 Biventricular Cardiac Resynchronization ( Crt-P ) Device With Bipolar Lv Lead, Full Body 3 Tesla Mri Compatible.With =4 Vector For Pacing From Lv Lead, Having Dedicated Subselect Catheter For Cannulation Of Selective Coronary Sinus Branch, Having Both Peel-Away And Slittable Lv Lead Introducer Sheath.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 38 Pulse Generator For Serial No. 36 ( Biventricular Cardiac Resynchronization ( Crt-P ) Device With Bi-Polar Lv Lead, 3 T Mri Compatible ) . 39 Biventricular Cardiac Resynchronization ( Crt-P ) Device With Quadripolar Lv Lead.With =4 Vector For Pacing From Lv Lead, Having Dedicated Subselect Catheter For Cannulation Of Selective Coronary Sinus Branch, Having Both Peel-Away And Slittable Lv Lead Introducer Sheath.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 40 Pulse Generator For Serial No. 38 ( Biventricular Cardiac Resynchronization ( Crt-P ) Device With Quadripolar Lv Lead ) . 41 Biventricular Cardiac Resynchronization ( Crt-P ) Device With Quadripolar Lv Lead, 1.5 Tesla Mri Compatible.With =4 Vector For Pacing From Lv Lead, Having Dedicated Subselect Catheter For Cannulation Of Selective Coronary Sinus Branch, Having Both Peel-Away And Slittable Lv Lead Introducer Sheath.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 42 Pulse Generator For Serial No. 40 ( Biventricular Cardiac Resynchronization ( Crt-P ) Device With Quadripolar Lv Lead, 1.5 T Mri Compatible ) . 43 Biventricular Cardiac Resynchronization ( Crt-P ) Device With Quadripolar Lv Lead, Full Body 3 Tesla Mri Compatible.With =4 Vector For Pacing From Lv Lead, Having Dedicated Subselect Catheter For Cannulation Of Selective Coronary Sinus Branch, Having Both Peel-Away And Slittable Lv Lead Introducer Sheath.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 44 Pulse Generator For Serial No. 42 ( Biventricular Cardiac Resynchronization ( Crt-P ) Device With Quadripolar Lv Lead, 3 T Mri Compatible ) . 45 Biventricular Cardiac Resynchronization ( Crt-P ) Device With Epicardial Lv Lead.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 46 Pulse Generator For Serial No. 44 ( Biventricular Cardiac Resynchronization ( Crt-P ) Device With Epicardial Lv Lead ) . 47 Biventricular Cardiac Resynchronization ( Crt-P ) Device With Epicardial Lv Lead, 1.5 Tesla Mri Compatible.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 48 Pulse Generator For Serial No. 46 ( Biventricular Cardiac Resynchronization ( Crt-P ) Device With Epicardial Lv Lead, 1.5 T Mri Compatible ) . 49 Biventricular Cardiac Resynchronization ( Crt-P ) Device With Epicardial Lv Lead, Full Body 3 Tesla Mri Compatible.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 50 Pulse Generator For Serial No. 48 ( Biventricular Cardiac Resynchronization ( Crt-P ) Device With Epicardial Lv Lead, 3 T Mri Compatible ) . 51 Combo Device ( Crt-D ) With Bipolar Lv Lead.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 52 Pulse Generator For Serial No. 50 ( Combo Device ( Crt-D ) With Bipolar Lv Lead. ) 53 Combo Device ( Crt-D ) With Bipolar Lv Lead. 1.5 Tesla Mri Compatible.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 54 Pulse Generator For Serial No. 52 ( Combo Device ( Crt-D ) With Bipolar Lv Lead. 1.5 Tesla Mri Compatible. ) 55 Combo Device ( Crt-D ) With Bipolar Lv Lead. Full Body 3 Tesla Mri Compatible.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 56 Pulse Generator For Serial No. 54 ( Combo Device ( Crt-D ) With Bipolar Lv Lead. 3 Tesla Mri Compatible. ) 57 Combo Device ( Crt-D ) With Bipolar Lv Lead. Less Weight ( Approx =75±5 Gm. ) And Small Volume ( Approx =30±6 Cc ) , Possibility Of =5 Pacing Vectors With Bipolar Lv Lead.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 58 Pulse Generator For Serial No. 56. 59 Combo Device ( Crt-D ) With Bipolar Lv Lead, 1.5 Tesla Mri Compatible. Less Weight ( Approx =75±5 Gm. ) And Small Volume ( Approx =30±6 Cc ) , Possibility Of =5 Pacing Vectors With Bipolar Lv Lead. Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 60 Pulse Generator For Serial No. 58 61 Combo Device ( Crt-D ) With Bipolar Lv Lead, Full Body 3 Tesla Mri Compatible. Less Weight ( Approx =75±5 Gm. ) And Small Volume ( Approx =30±6 Cc ) , Possibility Of =5 Pacing Vectors With Bipolar Lv Lead.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 62 Pulse Generator For Serial No. 60 63 Combo Device ( Crt-D ) With Quadripolar Lv Lead.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 64 Pulse Generator For Serial No. 62 ( Combo Device ( Crt-D ) With Quadripolar Lv Lead. ) 65 Combo Device ( Crt-D ) With Quadripolar Lv Lead. 1.5 Tesla Mri Compatible.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 66 Pulse Generator For Serial No. 64 ( Combo Device ( Crt-D ) With Quadripolar Lv Lead. 1.5 Tesla Mri Compatible. ) 67 Combo Device ( Crt-D ) With Quadripolar Lv Lead. Full Body 3 Tesla Mri Compatible.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 68 Pulse Generator For Serial No. 66 ( Combo Device ( Crt-D ) With Quadripolar Lv Lead. 3 Tesla Mri Compatible. ) 69 Combo Device ( Crt-D ) With Quadripolar Lv Lead. Less Weight ( Approx =75±5 Gm. ) And Small Volume ( Approx =30±6 Cc ) , Possibility Of =15 Pacing Vectors With The Quadripolar Lv Lead.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 70 Pulse Generator For Serial No. 68 71 Combo Device ( Crt-D ) With Quadripolar Lv Lead, 1.5 Tesla Mri Compatible. Less Weight ( Approx =75±5 Gm. ) And Small Volume ( Approx =30±6 Cc ) , Possibility Of =15 Pacing Vectors With The Quadripolar Lv Lead.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 72 Pulse Generator For Serial No. 70 73 Combo Device ( Crt-D ) With Quadripolar Lv Lead, Full Body 3 Tesla Mri Compatible. Less Weight ( Approx =75±5 Gm. ) And Small Volume ( Approx =30±6 Cc ) , Possibility Of =15 Pacing Vectors With The Quadripolar Lv Lead.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 74 Pulse Generator For Serial No. 72 75 Combo Device ( Crt-D ) With Bipolar Lv Lead, With Df-4 Connector Of Rv Lead. Less Weight ( Approx =75±5 Gm. ) And Small Volume ( Approx =30±6 Cc ) , Possibility Of =5 Pacing Vectors With Bipolar Lv Lead.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 76 Pulse Generator For Serial No. 74 77 Combo Device ( Crt-D ) With Bipolar Lv Lead, Df-4 Connector Of Rv Lead, 1.5 Tesla Mri Compatible. Less Weight ( Approx =75±5 Gm. ) And Small Volume ( Approx =30±6 Cc ) , Possibility Of =5 Pacing Vectors With Bipolar Lv Lead.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 78 Pulse Generator For Serial No. 76 79 Combo Device ( Crt-D ) With Bipolar Lv Lead, Df-4 Connector Of Rv Lead, Full Body 3 Tesla Mri Compatible. Less Weight ( Approx =75±5 Gm. ) And Small Volume ( Approx =30±6 Cc ) , Possibility Of =5 Pacing Vectors With Bipolar Lv Lead.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 80 Pulse Generator For Serial No. 78 81 Combo Device ( Crt-D ) With Quadripolar Lv Lead, Df-4 Connector Of Rv Lead. Less Weight ( Approx =75±5 Gm. ) And Small Volume ( Approx =30±6 Cc ) , With Possibility Of =15 Pacing Vectors With Quadripolar Lv Lead.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 82 Pulse Generator For Serial No. 80 83 Combo Device ( Crt-D ) With Quadripolar Lv Lead, Df-4 Connector Of Rv Lead, 1.5 Tesla Mri Compatible. Less Weight ( Approx =75±5 Gm. ) And Small Volume ( Approx =30±6 Cc ) , With Possibility Of =15 Pacing Vectors With Quadripolar Lv Lead.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 84 Pulse Generator For Serial No. 82 85 Combo Device ( Crt-D ) With Quadripolar Lv Lead, Df-4 Connector Of Rv Lead, Full Body 3T Mri Compatible. Less Weight ( Approx =75±5 Gm. ) And Small Volume ( Approx =30±6 Cc ) , With Possibility Of =15 Pacing Vectors With Quadripolar Lv Lead.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 86 Pulse Generator For Serial No. 84 87 Combo Device ( Crt-D ) With Epicardial Lv Lead.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 88 Pulse Generator For Serial No. 86 89 Combo Device ( Crt-D ) With Epicardial Lv Lead, 1.5 Tesla Mri Compatible. Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 90 Pulse Generator For Serial No. 88 91 Combo Device ( Crt-D ) With Epicardial Lv Lead, Full Body 3T Mri Compatible.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 92 Pulse Generator For Serial No. 90 93 Implantable Cardioverter Defibrillator: Single Chamber.Device With Lead ( Passive Tined Or Active Screwing ) 94 Pulse Generator For Serial No. 92 ( Implantable Cardioverter Defibrillator: Single Chamber. ) 95 Implantable Cardioverter Defibrillator: Single Chamber, 1.5 Tesla Mri Compatible.Device With Lead ( Passive Tined Or Active Screwing ) 96 Pulse Generator For Serial No. 94 ( Implantable Cardioverter Defibrillator: Single Chamber, 1.5 T Mri Compatible. ) 97 Implantable Cardioverter Defibrillator: Single Chamber, Full Body 3T Mri Compatible.Device With Lead ( Passive Tined Or Active Screwing ) 98 Pulse Generator For Serial No. 96 ( Implantable Cardioverter Defibrillator: Single Chamber, 3 T Mri Compatible. ) 99 Implantable Cardioverter Defibrillator: Single Chamber With Df-4 Header. Device With Lead ( Passive Tined Or Active Screwing ) And Introducers. 100 Pulse Generator For Serial No. 98 ( Implantable Cardioverter Defibrillator: Single Chamber With Df-4 Header ) 101 Implantable Cardioverter Defibrillator: Single Chamber With Df-4 Header, 1.5 Tesla Mri Compatible.Device With Lead ( Passive Tined Or Active Screwing ) And Introducers. 102 Pulse Generator For Serial No. 100 ( Implantable Cardioverter Defibrillator: Single Chamber With Df-4 Header, 1.5 T Mri Compatible. ) 103 Implantable Cardioverter Defibrillator: Single Chamber With Df-4 Header, Full Body 3T Mri Compatible.Device With Lead ( Passive Tined Or Active Screwing ) And Introducers. 104 Pulse Generator For Serial No. 102 ( Implantable Cardioverter Defibrillator: Single Chamber With Df-4 Header, 3 T Mri Compatible. ) 105 Implantable Cardioverter Defibrillator: Dual Chamber.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 106 Pulse Generator For Serial No. 104 ( Implantable Cardioverter Defibrillator: Dual Chamber. ) 107 Implantable Cardioverter Defibrillator: Dual Chamber, 1.5 Tesla Mri Compatible.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 108 Pulse Generator For Serial No. 106 ( Implantable Cardioverter Defibrillator: Dual Chamber, 1.5 T Mri Compatible. ) 109 Implantable Cardioverter Defibrillator: Dual Chamber, Full Body 3 Tesla Mri Compatible.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 110 Pulse Generator For Serial No. 108 ( Implantable Cardioverter Defibrillator: Dual Chamber, 3 T Mri Compatible. ) 111 Implantable Cardioverter Defibrillator: Dual Chamber. Less Weight ( Approx =60±5 Gm. ) And Small Volume ( Approx =25±5 Cc ) With Advanced Features Of Automatic Av Search, Adjustable Av Delay Etc.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 112 Pulse Generator For Serial No. 110 113 Implantable Cardioverter Defibrillator: Dual Chamber, 1.5 Tesla Mri Compatible. Less Weight ( Approx =60±5 Gm. ) And Small Volume ( Approx =25±5 Cc ) With Advanced Features Of Automatic Av Search, Adjustable Av Delay Etc.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 114 Pulse Generator For Serial No. 112 115 Implantable Cardioverter Defibrillator: Dual Chamber, Full Body 3 Tesla Mri Compatible. Less Weight ( Approx =60±5 Gm. ) And Small Volume ( Approx =25±5 Cc ) With Advanced Features Of Automatic Av Search, Adjustable Av Delay Etc.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 116 Pulse Generator For Serial No. 114 117 Implantable Cardioverter Defibrillator: Dual Chamber With Df-4 Header. Less Weight ( Approx =60±5 Gm. ) And Small Volume ( Approx =25±5 Cc ) With Advanced Features Of Automatic Av Search, Adjustable Av Delay Etc.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 118 Pulse Generator For Serial No. 116 119 Implantable Cardioverter Defibrillator: Dual Chamber With Df-4 Header, With 1.5 Tesla Mri Compatible. Less Weight ( Approx =60±5 Gm. ) And Small Volume ( Approx =25±5 Cc ) With Advanced Features Of Automatic Av Search, Adjustable Av Delay Etc.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 120 Pulse Generator For Serial No. 118 121 Implantable Cardioverter Defibrillator: Dual Chamber With Df-4 Header, With Full Body 3 Tesla Mri Compatible. Less Weight ( Approx =60±5 Gm. ) And Small Volume ( Approx =25±5 Cc ) With Advanced Features Of Automatic Av Search, Adjustable Av Delay Etc.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 122 Pulse Generator For Serial No. 120 123 Subcutaneous Icd.Device With Lead And All Accessories For Implantation 124 Pulse Generator For Serial No. 122 125 Mri Compatible Subcutaneous Icd.Device With Lead And All Accessories For Implantation 126 Pulse Generator For Serial No. 124 127 Permanent Pacing Lead ( Ventricular / Atrial Endocardial Bipolar, Passive Fixation With Tines ) , Steroid Eluting, Is-1 Header With The Introducer Sheath And Puncture Set ( Pli ) . 128 Permanent Pacing Lead ( Ventricular / Atrial Endocardial Bipolar, Passive Fixation With Tines ) , Steroid Eluting, Is-1 Header With The Introducer Sheath And Puncture Set ( Pli ) . 129 1.5 Tesla Mri Compatible Permanent Pacing Lead ( Ventricular / Atrial Endocardial Bipolar, Passive Fixation With Tines ) , Steroid Eluting, Is-1 Header With The Introducer Sheath And Puncture Set ( Pli ) . 130 3 Tesla Full Body Mri Compatible Permanent Pacing Lead ( Ventricular / Atrial Endocardial Bipolar, Passive Fixation With Tines ) , Steroid Eluting, Is-1 Header With The Introducer Sheath And Puncture Set ( Pli ) . 131 3 Tesla Full Body Mri Compatible Permanent Pacing Lead ( Ventricular / Atrial Endocardial Bipolar, Passive Fixation With Tines ) , Steroid Eluting, Is-1 Header With The Introducer Sheath And Puncture Set ( Pli ) . 132 Permanent Pacing Lead ( Ventricular / Atrial Endocardial Bipolar, Active Fixation Steroid Eluting Screw In Lead ) With Is-1 Header With The Introducer Sheath And Puncture Set ( Pli ) . 133 1.5 Tesla Mri Compatible Permanent Pacing Lead ( Ventricular / Atrial Endocardial Bipolar, Active Fixation Steroid Eluting Screw In Lead ) With Is-1 Header With The Introducer Sheath And Puncture Set ( Pli ) . 134 3 Tesla Full Body Mri Compatible Permanent Pacing Lead ( Ventricular / Atrial Endocardial Bipolar, Active Fixation Steroid Eluting Screw In Lead ) With Is-1 Header With The Introducer Sheath And Puncture Set ( Pli ) . 135 3 Tesla Full Body Mri Compatible Permanent Pacing Lead ( Ventricular / Atrial Endocardial Bipolar, Active Fixation Steroid Eluting Screw In Lead ) With Is-1 Header With The Introducer Sheath And Puncture Set ( Pli ) . 136 Unipolar, Mri Compatible, Epicardial Permanent Screw-In Pacing Lead, Steroid Eluting, Is-1 Header With The Deploying Kit And Introducer Set. 137 Unipolar, Mri Compatible, Epicardial Permanent Screw-In Pacing Lead, Steroid Eluting, Is-1 Header With The Deploying Kit And Introducer Set. 138 Bipolar, Mri Compatible, Epicardial Permanent Screw-In Pacing Lead, Steroid Eluting, Is-1 Header With The Deploying Kit. 139 Bipolar, Mri Compatible, Epicardial Permanent Screw-In Pacing Lead, Steroid Eluting, Is-1 Header With The Deploying Kit. 140 Mri Compatible Short ( 45±3 Cm ) Endocardial Bipolar Pacing Lead With Introducer Sheath And Puncture Set ( Pli ) . 141 Only Introducer Kit For Endocardial Ra / Rv / Icd Leads ( Without Leads ) , 6F, 7F, 8F. 142 Permanent Defibrillation Lead, Bipolar, Endocardial Steroid Eluting Tipped, Df-1 Header, With The Introducer Kit And Puncture Set ( Pli ) . Tined End 143 Permanent Defibrillation Lead, Bipolar, Endocardial Steroid Eluting Tipped, Df-1 Header, With The Introducer Kit And Puncture Set ( Pli ) . Screw In Lead 144 Permanent Defibrillation Lead, Bipolar, Endocardial Steroid Eluting Leads, Df-1 Header, With The Introducer Sheath And Puncture Set ( Pli ) . 1.5 Tesla Full Body Mri Compatible.Tined Lead 145 Permanent Defibrillation Lead, Bipolar, Endocardial Steroid Eluting Leads, Df-1 Header, With The Introducer Sheath And Puncture Set ( Pli ) . 1.5 Tesla Full Body Mri Compatible.Screw Lead 146 Permanent Defibrillation Lead, Bipolar, Endocardial Steroid Eluting Leads, Df-1 Header, With The Introducer Sheath And Puncture Set ( Pli ) . 3 Tesla Full Body Mri Compatible.Tined Lead 147 Permanent Defibrillation Lead, Bipolar, Endocardial Steroid Eluting Leads, Df-1 Header, With The Introducer Sheath And Puncture Set ( Pli ) . 3 Tesla Full Body Mri Compatible.Screw Lead 148 Permanent Defibrillation Lead, Bipolar, Endocardial Steroid Eluting Tipped, With Df-4 Header, With The Introducer Kit And Puncture Set ( Pli ) .Tined End 149 Permanent Defibrillation Lead, Bipolar, Endocardial Steroid Eluting Tipped, With Df-4 Header, With The Introducer Kit And Puncture Set ( Pli ) .Screw End 150 Permanent Defibrillation Lead, Bipolar, Endocardial Steroid Eluting Tipped, Df-4 Header, With The Introducer Kit And Puncture Set ( Pli ) , 1.5 Tesla Mri Compatible.Tined End 151 Permanent Defibrillation Lead, Bipolar, Endocardial Steroid Eluting Tipped, Df-4 Header, With The Introducer Kit And Puncture Set ( Pli ) , 1.5 Tesla Mri Compatible.Screw End 152 Permanent Defibrillation Lead, Bipolar, Endocardial Steroid Eluting Tipped, Df-4 Header, With The Introducer Kit And Puncture Set ( Pli ) , Full Body 3 Tesla Mri Compatible.Tined End 153 Permanent Defibrillation Lead, Bipolar, Endocardial Steroid Eluting Tipped, Df-4 Header, With The Introducer Kit And Puncture Set ( Pli ) , Full Body 3 Tesla Mri Compatible.Screw End 154 Bipolar Endocardial Lv Lead With Introducer Kit And Puncture Set ( Pli ) . 155 Bipolar Endocardial Lv Lead With Introducer Kit And Puncture Set ( Pli ) , 1.5 Tesla Mri Compatible. 156 Bipolar Endocardial Lv Lead With Introducer Kit And Puncture Set ( Pli ) , Full Body 3 Tesla Mri Compatible. 157 Quadripolar Endocardial Lv Lead With Introducer Kit And Puncture Set ( Pli ) . 158 Quadripolar Endocardial Lv Lead With Introducer Kit And Puncture Set ( Pli ) , 1.5 Tesla Mri Compatible. 159 Quadripolar Endocardial Lv Lead With Introducer Kit And Puncture Set ( Pli ) , Full Body 3 Tesla Mri Compatible. 160 Quadripolar Endocardial Lv Lead For Multisite Pacing With Introducer Kit And Puncture Set ( Pli ) , Full Body 3 Tesla Mri Compatible. 161 Cs Cannulation Kit Only ( Without The Lv Lead ) With All Accessories Like Sheath, Puncture Needle, Syringe, 0.035” Long Guidewire. 162 External Event Recording Of Upto One Week Of Arrhythmic Events, Portable, Easy To Operate With 1 / 3 Lead System And Easy Operation By Patient / Relatives At Home. 163 Patch Type External Event Recorder, Disposable, Wireless, Easy To Use Smart Biosensor, Shower-Proof For Recording Upto One Week Of Arrhythmic Events, And Easy Operation By Patient / Relatives At Home. 164 Implantable Event / Loop Recorder For Recording Of Arrhythmic Events For Prolong Period Of Upto 2 Years. 165 Digital Multi-Programmable Pacemaker With Features Of Automatic Detection Of Mri And Conditioning Whenever The Device / Patient Comes To An Mri Environment Or Mr Room For Mri And With Automatic Timeout Feature, Bringing Back The Normal Settings Whenever The Set Window Period Is Over.Mode: Vvirdevice With Lead And All Accessories 166 Pulse Generator For Serial No. 159 167 Digital Multi-Programmable Pacemaker With Features Of Automatic Detection Of Mri And Conditioning Whenever The Device / Patient Comes To An Mri Environment Or Mr Room For Mri And With Automatic Timeout Feature, Bringing Back The Normal Settings Whenever The Set Window Period Is Over.Mode: Dddrdevice With Leads And All Accessories 168 Pulse Generator For Serial No. 161 169 Crt-D With Features Of Automatic Detection Of Mri And Conditioning Whenever The Device / Patient Comes To An Mri Environment Or Mr Room For Mri And With Automatic Timeout Feature, Bringing Back The Normal Settings Whenever The Set Window Period Is Over.Mode: Crt-D With Bipolar Lv Leaddevice With Leads And All Accessories 170 Pulse Generator For Serial No. 163 171 Crt-D With Features Of Automatic Detection Of Mri And Conditioning Whenever The Device Comes To An Mri Environment Or Mr Room For Mri And With Automatic Timeout Feature, Bringing Back The Normal Settings Whenever The Set Window Period Is Over.Mode: Crt-D With Quadripolar Lv Leaddevice With Leads And All Accessories 172 Pulse Generator For Serial No. 165 173 Single Chamber Icd With Features Of Automatic Detection Of Mri And Conditioning Whenever The Device Comes To An Mri Environment Or Mr Room For Mri And With Automatic Timeout Feature, Bringing Back The Normal Settings Whenever The Set Window Period Is Over.Mode: Icd ( Single Chamber ) Device With Leads And All Accessories 174 Pulse Generator For Serial No. 167 175 Dual Chamber Icd With Features Of Automatic Detection Of Mri And Conditioning Whenever The Device Comes To An Mri Environment Or Mr Room For Mri And With Automatic Timeout Feature, Bringing Back The Normal Settings Whenever The Set Window Period Is Over.Mode: Icd ( Dual Chamber ) Device With Leads And All Accessories 176 Pulse Generator For Serial No. 169 177 Combo Device ( Crt-D ) With Quadripolar Lv Lead Having Features Of Multi-Site Pacing From Lv Lead.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 178 Pulse Generator For Serial No. 171 179 Combo Device ( Crt-D ) With Quadripolar Lv Lead Having Features Of Multi-Site Pacing From Lv Lead, 1.5 Tesla Mri Compatible.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 180 Pulse Generator For Serial No. 173 181 Combo Device ( Crt-D ) With Quadripolar Lv Lead Having Features Of Multi-Site Pacing From Lv Lead, Full Body 3 Tesla Mri Compatible.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 182 Pulse Generator For Serial No. 175 183 Combo Device ( Crt-D ) With Quadripolar Lv Lead Having Features Of Multi-Site Pacing From Lv Lead. Df-4 Rv Lead. Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 184 Pulse Generator For Serial No. 177 185 Combo Device ( Crt-D ) With Quadripolar Lv Lead Having Features Of Multi-Site Pacing From Lv Lead, Df-4 Rv Lead, 1.5 Tesla Mri Compatible.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 186 Pulse Generator For Serial No. 179 187 Combo Device ( Crt-D ) With Quadripolar Lv Lead Having Features Of Multi-Site Pacing From Lv Lead, Df-4 Rv Lead, 3 Tesla Full Body Mri Compatible. Less Weight ( Approx =75±5 Gm. ) And Small Volume ( Approx =30±6 Cc ) . Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 188 Pulse Generator For Serial No. 181 189 Digital Multi-Programmable Pacemaker With Limited Warranty For 10 Years.Mode: Single Chamber: Vvi / Aai. With Dynamic Adjustment Of Pacing Output. Digital High Sampling Rate Of P / R Wave And Automated Ventricular Rate Stabilization During Af And With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.With =6F Compatible Passive-Fixation Tined Lead Or Screw In Lead & Lead Introducer. 190 Digital Multi-Programmable Pacemaker With Limited Warranty For 10 Years. Mode: Single Chamber: Vvi / Aai. With Dynamic Adjustment Of Pacing Output. Digital High Sampling Rate Of P / R Wave And Automated Ventricular Rate Stabilization During Af.A. With 6F Compatible Passivefixation Tined Lead Or Screw In Lead & Lead Introducer. 191 Pulse Generator For Serial No. 183.1 192 Pulse Generator For Serial No. 183.2 193 Digital Multi-Programmable Pacemaker With Limited Warranty For 10 Years, 1.5 Tesla Mri Compatible.Mode: Single Chamber: Vvi / Aai. With Dynamic Adjustment Of Pacing Output. Digital High Sampling Rate Of P / R Wave And Automated Ventricular Rate Stabilization During Af And With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.With =6F Compatible Passive-Fixation Tined Lead Or Screw In Lead & Lead Introducer. 194 Pulse Generator For Serial No. 185 195 Digital Multi-Programmable Pacemaker With Limited Warranty For 10 Years, Full Body 3 Tesla Mri Compatible.Mode: Single Chamber: Vvi / Aai. With Dynamic Adjustment Of Pacing Output. Digital High Sampling Rate Of P / R Wave And Automated Ventricular Rate Stabilization During Af And With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.With =6F Compatible Passive-Fixation Tined Lead Or Screw In Lead & Lead Introducer. 196 Pulse Generator For Serial No. 187 197 Digital Multi-Programmable Pacemaker With Limited Warranty For 10 Years.Mode: Single Chamber: Vvir / Aair. With Dynamic Adjustment Of Pacing Output. Digital High Sampling Rate Of P / R Wave And Automated Ventricular Rate Stabilization During Af And With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.With =6F Compatible Passive-Fixation Tined Lead Or Screw In Lead & Lead Introducer. 198 Pulse Generator For Serial No. 189 199 Digital Multi-Programmable Pacemaker With Limited Warranty For 10 Years, 1.5 Tesla Mri Compatible.Mode: Single Chamber: Vvir / Aair. With Dynamic Adjustment Of Pacing Output. Digital High Sampling Rate Of P / R Wave And Automated Ventricular Rate Stabilization During Af And With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.With =6F Compatible Passive-Fixation Tined Lead Or Screw In Lead & Lead Introducer. ( Golden Parameters: ( I ) =6F Sheath Compatible Lead, ( Ii ) Automated Ventricular Rate Stabilization In Af, ( Iii ) 1.5 T Mri Compatibility, ( Iv ) Automatic Capture ) 200 Pulse Generator For Serial No. 191 201 Digital Multi-Programmable Pacemaker With Limited Warranty For 10 Years, Full Body 3 Tesla Mri Compatible.Mode: Single Chamber: Vvir / Aair. With Dynamic Adjustment Of Pacing Output. Digital High Sampling Rate Of P / R Wave And Automated Ventricular Rate Stabilization During Afand With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.With =6F Compatible Passive-Fixation Tined Lead Or Screw In Lead & Lead Introducer. 202 Pulse Generator For Serial No. 193 203 Digital Multi-Programmable Pacemaker With Lifetime Warranty.Mode: Dual Chamber: Dddr. With Features Of Automatic Threshold Check, Auto Adjusting Of Av Delay ( Extendable Upto 400 Ms ) , Automatic Intrinsic Activity Search, And Atp. With Dynamic Adjustment Of Pacing Output And Proven Longevity Of >10 Years With 100% Pacing Of Ra & Rv And With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.With =6F Compatible Passive-Fixation Tined Leads Or Screw In Leads & Lead Introducers. 204 Digital Multi - Programmable Pacemaker With Lifetime Warranty.Mode: Dual Chamber: Dddr With Features Of Automatic Threshold Check, Auto Adjusting Of Av Delay ( Extendable Upto 400Ms ) , And Automatic Intrinsic Activity Search. With Dynamic Adjustment Of Pacing Output Ad Proven Longevity Of >10 Years With 100% Pacing Of Ra & Rv.A. With 6F Compatible Passivefixation Tined Leads Or Screw In Leads And Lead Introducers. 205 Pulse Generator For Serial No. 195A 206 Pulse Generator For Serial No. 195B 207 Digital Multi-Programmable Pacemaker With Lifetime Warranty.Mode: Dual Chamber: Dddr. With Features Of Automatic Threshold Check, Auto Adjusting Of Av Delay ( Extendable Upto 400 Ms ) , Automatic Intrinsic Activity Search, And Atp. With Dynamic Adjustment Of Pacing Output And Proven Longevity Of >10 Years With 100% Pacing Of Ra & Rv. 1.5 Tesla Mri Compatible And With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.With =6F Compatible Passive-Fixation Tined Leads Or Screw In Leads & Lead Introducers. 208 Pulse Generator For Serial No. 197 209 Digital Multi-Programmable Pacemaker With Lifetime Warranty.Mode: Dual Chamber: Dddr. With Features Of Automatic Threshold Check, Auto Adjusting Of Av Delay ( Extendable Upto 400 Ms ) , Automatic Intrinsic Activity Search, And Atp. With Dynamic Adjustment Of Pacing Output And Proven Longevity Of >10 Years With 100% Pacing Of Ra & Rv And With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch. Full Body 3 Tesla Mri Compatible.With =6F Compatible Passive-Fixation Tined Leads Or Screw In Leads & Lead Introducers. 210 Digital Multi - Programmable Pacemaker With Lifetime Warranty, Full Body 3 Tesla Mri Compatible.Mode: Dual Chamber: Dddr. With Features Of Automatic Threshold Check, Auto Adjusting Of Av Delay ( Extendable Up To 400Ms ) , And Automatic Intrinsic Activity Search. With Dynamic Adjustment Of Pacing Output And Proven Longevity Of >10 Years With 100% Pacing Of Ra & Rv.A. With 6F Compatible Passive Fixation Tined Leads Or Screw In Or Active Screwing ) And Introducers. 211 Pulse Generator For Serial No. 199A 212 Pulse Generator For Serial No. 199B 213 Digital Multi-Programmable Pacemaker With Lifetime Warranty With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.Mode: Dual Chamber: Dddr. With Features Of Automatic Threshold Check, Auto Adjusting Of Av Delay ( Extendable Upto 400 Ms ) , And Automatic Intrinsic Activity Search. With Dynamic Adjustment Of Pacing Output And Proven Longevity Of >10 Years With 100% Pacing Of Ra & Rv And With Closed Loop Stimulation. With =6F Compatible Passive-Fixation Tined Leads Or Screw In Leads & Lead Introducers. 214 Pulse Generator For Serial No.201 215 Digital Multi-Programmable Pacemaker With Lifetime Warranty With Automatic Capture Facility For Rescue Pacing And Automatic Lead Polarity Switch.Mode: Dual Chamber: Dddr. With Features Of Automatic Threshold Check, Auto Adjusting Of Av Delay ( Extendable Upto 400 Ms ) , And Automatic Intrinsic Activity Search. With Dynamic Adjustment Of Pacing Output And Proven Longevity Of >10 Years With 100% Pacing Of Ra & Rv And With Minute Ventilation Sensor.With =6F Compatible Passive-Fixation Tined Leads Or Screw In Leads & Lead Introducers. 216 Pulse Generator For Serial No.203 217 Implantable Cardioverter Defibrillator: Vdd With Single Lead.Device With Lead ( Passive Tined Or Active Screwing ) And Introducer Set. 218 Pulse Generator For Serial No. 205 219 Implantable Cardioverter Defibrillator: Vdd With Single Lead, 1.5 Tesla Mri Compatible.Device With Lead ( Passive Tined Or Active Screwing ) And Introducer Set. 220 Pulse Generator For Serial No. 207 221 Implantable Cardioverter Defibrillator: Vdd With Single Lead, Full Body 3 Tesla Mri Compatible.Device With Lead ( Passive Tined Or Active Screwing ) And Introducer Set. 222 Pulse Generator For Serial No. 209 223 Mri Compatible Leadless Pacemaker With All Accessories For Implantation. Vvir Type. 224 3 Tesla & / 1.5 Tesla Full Body Mri Conditional Multi-Programmable, Quadripolar Lead, Auto Capture Management For Ra, Rv & Lv, Automatic Atrial Anti Tachy Therapies, Heart Failure Diagnostics With Trans Thoracic Fluid Impedance Measurement And Rate Drop Response, Multi-Site / Multipoint Pacing Crt-P. 225 Pulse Generator For Serial No. 212 226 3 Tesla & / 1.5 Tesla Full Body Mri Conditional Multi-Programmable, Quadripolar Lead, Auto Capture Management For Ra, Rv & Lv, Automatic Atrial Anti Tachy Therapies, Heart Failure Diagnostics With Trans Thoracic Fluid Impedance Measurement And Rate Drop Response, Multi-Site / Multipoint Pacing Crt-D. 227 Pulse Generator For Serial No. 214 228 Dddr Pacemaker With Rate Response, Af Diagnostic And Heart Failure Management. 229 Pulse Generator For Serial No. 216 230 3.0 Tesla Dddr Pacemaker With Auto Rate Response, Af Diagnostic And Heart Failure Management. 231 Pulse Generator For Serial No. 218 232 His Bundle Pacing Systema ) Complete System With Leadsb ) Ipg Onlyc ) His Bundle Lead Only 233 Pulse Generator For Serial No. 220 234 3 Tesla Mri Compatible His Bundle Pacing Systema ) Complete System With Leadsb ) Ipg Onlyc ) His Bundle Lead Only 235 Pulse Generator For Serial No. 222 236 Adaptor For Old Pacing Lead To Is-I Compatible 237 Latex Free Compression Set With Soft Material For Pacemaker / Icd Implantation After Care. 238 Implantable Cardioverter Defibrillator: Single Chamber. With 8 Years Full Warranty Plus 2 Years Warranty On Pro-Rata Basis.Device With Lead ( Passive Tined Or Active Screwing ) And Introducer Set. 239 Pulse Generator For Serial No. 226 240 Implantable Cardioverter Defibrillator: Single Chamber, 3 Tesla Mri Compatible. With 8 Years Full Warranty Plus 2 Years Warranty On Pro-Rata Basis.Device With Lead ( Passive Tined Or Active Screwing ) And Introducer Set. 241 Pulse Generator For Serial No. 228 242 Implantable Cardioverter Defibrillator: Dual Chamber With 5 Years Full Warranty Plus 3 Years Warranty On Pro-Rata Basis. Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 243 Pulse Generator For Serial No. 230 244 Implantable Cardioverter Defibrillator: Dual Chamber, 3 Tesla Mri Compatible. With 5 Years Full Warranty Plus 3 Years Warranty On Pro-Rata Basis.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 245 Pulse Generator For Serial No. 232 246 Combo Device ( Crt-D ) With Quadripolar Lv Lead, With 4 Years Full Warranty Plus 2 Years Warranty On Pro-Rata Basis.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 247 Pulse Generator For Serial No. 234 248 Combo Device ( Crt-D ) With Quadripolar Lv Lead, With 4 Years Full Warranty Plus 2 Years Warranty On Pro-Rata Basis. 3 Tesla Mri Compatible.Device With All Leads ( Passive Tined Or Active Screwing ) And Introducers. 249 Pulse Generator For Serial No. 236 250 Mri Compatible Av Leadless Pacemaker ( Av Micra ) With All Accessories For Implantation. 251 His Bundle Dddr Pacemaker. ( A. ) Multi-Programmable Dual Chamber Rate Responsive Full Body 3 T Mri Compatible Pacemaker. ( B. ) Atrial Endocardial Leads Both Active And Passive Fixation Is-1 Bipolar And Unipolar As Per Clinical Need. ( C. ) His Bundle With Lumen Pacing Lead With Catheter And All Accessories ( C. ) Auto Capture Output Management Software For Battery Optimization. ( D. ) Lead Polarity Switch ( E. ) With 8 Year Warranty Replacement Policy. ( F ) Automatic Detection Of Mri And Conditioning Whenever The Device / Patient Comes To An Mri Environment Or Mr Room For Mri And With Automatic Timeout Feature, Bringing Back The Normal Settings Whenever The Set Window Period Is Over. 252 Pulse Generator For Serial No. 239 253 His Bundle Dddr Pacemaker With Lifetime Warranty. ( A. ) Multi-Programmable Dual Chamber Rate Responsive Full Body 3 Tesla Mri Compatible Pacemaker. ( B. ) Atrial Endocardial Leads Both Active And Passive Fixation Is-1 Bipolar And Unipolar As Per Clinical Need. ( C. ) His Bundle With Lumen Pacing Lead With Catheter And All Accessories ( C. ) Auto Capture Output Management Software For Battery Optimization. ( D. ) Lead Polarity Switch ( E ) Automatic Detection Of Mri And Conditioning Whenever The Device / Patient Comes To An Mri Environment Or Mr Room For Mri And With Automatic Timeout Feature, Bringing Back The Normal Settings Whenever The Set Window Period Is Over. 254 Pulse Generator For Serial No. 241 255 His Bundle Dddr Pacemaker:Dual Chamber Rate Responsive 3 T Full Body Mri Compatible Pacemaker With His Bundle Lumen Lead And Delivery System With Features Of Automatic Detection Of Mri And Conditioning Whenever The Device / Patient Comes To An Mri Environment Or Mr Room For Mri And With Automatic Timeout Feature, Bringing Back The Normal Settings Whenever The Set Window Period Is Over. ( A. ) His Bundle Screwing Lead With Lumen ( B. ) With Delivery Catheter. 256 Pulse Generator For Serial No. 243

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 15-05-2023 Specifications Technical Bid 27-05-2023
2 16-05-2023 New Specifications Technical Bid 27-05-2023

Key Value

Document Fees
Refer document
EMD
INR 500000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail