Tender For Construction Of Health Sub- Center, Madgi In Dulmi Block, Dist- Ramgarh.

BOQ

Name of Work: Constrction of Health Sub- Center, Madgi in Dulmi Block, Dist- Ramgarh.
Sl. No. Item Description
1Earth work in Excavation in foundation trenches in ordinary soil (Vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lift,leveling,ramming the foundation trenches,removing roots of trees,shurbs all complete as per approved design,bulding specification and direction of E/I Extra for earthwork in hard soil as per specification and direction of E/l (vide classification of soil item-B)
2Filling in foundation trenches and plenth in layers not exceeding 150 mm. thick well watered ,rammed ,fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume).
3Providing Coarse clean sand filling in foundation and plinth including ramming, watering etc do all complete job as per specification and direction of EI
4Providing designation 75B one brick flat soling joints filled with local sand including cost of watering texes royalty all complete as per building specification and direction of E/I.
5Providing and laying in position cement concrete of specified grade excluding the cost of centering and shutfering All work up to plinth level:1:2:4 (1 cement: 2 coarse sand (zone-1) :4 graded stone aggregate 20 mm nominal size)
6Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shutterhe. finishing and reinforcement- All work upto plinth level.1:1.5:3 (1 cement: 1.5 course sand (zone-1): 3 graded stone geregate 20 mm nominal size)
7Reinforded cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:15:3 cement: 1.5 coarsesand(zone-l):3 graded stone aggregate 20 mmnominal size).
8Reinforded cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:15:3 cement: 1.5 coarsesand(zone-l):3 graded stone aggregate 20 mmnominal size).
9Reinforced cement concrete work in wals (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets column pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering & finishing and reinforcement : 1:1.5:3 cement: 1.5 coarse sand (zone-l):3 graded stone aggregate 20 mm nomina lsize)
10Reinforded cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:15:3 cement: 1.5 coarsesand(zone-l):3 graded stone aggregate 20 mm nominal size).
11Centring and shuttering including strutting, propping etc. and removal of form for foundation, footings, bases of columns etc. for mass concrete.
12Centring and shuttering including strutting, propping etc. and removal of form for lintel, beams, plinth beams, griders, bressumers and contilevers.
13Centring and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platform.
14Centring and shuttering including strutting, propping etc. and removal of form for columns, pillars, piers, abutments, posts and struts
15Centring and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platform.
16Providing TOR Steel reinforcement of 10mm ,12mm ,& 16mm. dia bars as per apporoved design and drawing excluding carrige of bars to work site ,cutting ,bending , and bending with annealed wire with cost of wire , removal of rust , placing the rods in position all cpomplete as per building specification and direction of E/I .TMTC-500 8mm dia
17TMTC-500 10mm dia
18TMTC-500 12mm dia
19TMT-500 16mm dia
20TMT-500 20mm dia
21Providing 75B brick work in C.M. (1:6) in foundation and plinth -do- -do- all complete job as per specification and direction of E/I.
22Providing designation 125 mmm thick reinforced designation 75A brick work in C.M.(1:4) in superstructure with approved quality of clean coarse sand of F. M.2 to 2.5 including the cost of screening , Carriage of materials , scaffolding, raking out joints to 15mm depth, curingh , taxes and royalty (but excluding the cost of reinforcement) all complete as per buildimg specification and direction of E/I.
23Providing designation 75 B Brick work in C.M (1:6) in superstructure with approved quality of clean coarse sand of F. M.2 to 2.5 including providing 10mm thick mortar joints costs of screening, materials , scaffolding, raking out joints to 15 mm depth curing , taxes and royalty all complete as per building specification and direction of E/I.
24Providing 12 mm thick cement plaster (1:3) -do- -do- all complete job as per specification and direcition of E/l.
25Providing 12 mm , cement plaster (1:6)with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water ,scaffolding taxes and royalty all complete as per building specification and direction of E/I.
26Providing 6 mm , cement plaster (1:4) in ceiling with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water ,scaffolding taxes and royalty all complete as per building specification and direction of E/I.
27Providing 1.5 mm thick neat cement punning -do- -do- all complete job as per specification and direcition of E/l.
28Providing and applying white cement based putty-do- all complete job as per specification and direcition of E/l.
29Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing wmooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
30Finishing walls with Acrylic Smooth exterior paint of required shade Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface all complete as per building specification and direction of E/I
31Providing 25 mm thick cement plaster(1:6) with clean corse sand with FM 1.25
32Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours, shades, except White, lvory, Grey, Fume Red Brown laid on 20mm thick bed of Cement Mortar 1:4 (1 cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc. complete.
33Providing and fixing 1st quality Ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the nufacturer) of approved make in all colours, shades, except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of step and dados over 12mm thick bed of Cement Mortar 1:3 (1 cement : 3 Coarse sand)and jointing with grey cementslurry @ 3.3 kg per sqm including pointing in white cement mixed with pigments of matchingshade complete.
34Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption\"s less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete.Size of Tile 600X600MM
35Kota stone slabs 25 mm thick in risers of steps skirting. Dado & pillars laid on 12 mm (average (thick cement mortar 1:3 (1cement: 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. Details of cost for 10 sqm. 20 to 25 mm thick -
36Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
37Supplying.fitting and fixing callapsible gate of approved size and make properly fabricated with vertical double channels 20X10X2 mm.at 100mm. Centres and braced with M.S. flat diagonals 20 X 3mm with top ad botom rails of T. iron 40x40x6mm with 38 mm dia steelpulleys complete with bolts, nuts, locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, carriage, hoisting and taxes all complete as per building specification Per M 4891.58and direction E.
38Supplying , fitting and fixing M.S grill with M.S. grills made of 20*6mm M.S flats or 16mm. M.S square bars fitted on 40*40*6mm.M.S. Angle frame--do-- (when steel is not supplied by the deptt.)
39Supplying , fitting and fixing good quality welldresssed sal wood choukhat all complete as per building specification and direction of E/I
40Supplying , fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges ,tawer bolts ,handle ,cleats and sand blocks and taxes all complete as per building specification and direction of E/I
41Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin-charge9.117.1 Extruded section profile size 48x40 mm
4224 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of \"H\" section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. \"U\" cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer\"s specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter).
43Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
44Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
45Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
46Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.15 mm nominal outer dia Pipes
4720 mm nominal outer dia Pipes
4815 mm dia nominal bore
4920 mm dia nominal bore
50Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :15 mm nominal bore
5120 mm nominal bore
52Providing and fixing PTMT bib cock of approved quality and colour.15 mm nominal bore, 122mm long, weighing not less than 99 gms
5315 mm nominal bore, 86 mm long, weighing not less than 88 gms
54Supply, fitting and fixing 40mm high vitreous white glazed earthen E.W.C with \"p\" trap of parry hindustan or any other approved ISS make including supplying and fixing 15 liters CI mosquito proof low down flushing cistern of approved make with complete fittings with CI handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grams 15 mm PVC alkathene pipe 45 cm. long with brass coupling at both ends and white /black plastic solid state seal and lead of commander /cuckoo or other ISS with hinges or screws etc painting pipe and cistern etc with 2 coats of approved paint over a coat of red oxide priming, all complete as per specification and direction of E/I
55Supplying fitting and fixing flat back or angular, lipped front vitreous white glazed earthen ware urinal of Hindustan \"Parry\" or any other approved ISS make with 5 liters capacity C.I. automatic fulsing cistern of reliance for any other I.S.S. approved make with all fittings clamps, 15 mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grams 15 mm P.V.C /Alkthene pipe 450 mm long with bras coupling at both ends and doing plumber joints including painting of exposed part with two coatsof approved paint over a priming coat of red oxide cutting wall and floor, making good the same etc all complete as per specification and direction of E/I
56Supplying and fitting and fixing viterous white glazed earthern ware wash hand basin of parry or Hindustan or any other I.S.S approved make supported or painted C.I. or R.S. brackets 32 mm C.I. brass waste, 15 mm dia C.I. body brass spindle stop cock of approved qaulity of weight not less than 350 grams, 32 mm P.V.C waste pipe 750 mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I
57Supplying fitting and fixing HCI pipes with ear of approved make confirming to I.S.I 1729 including supplying and bobins short pieces, cutting loose collars, lead and yarn for making lead caulked joints, cutting pipes to size including earth work or scaffolding where necessary etc. all complete as per specification anfd direction of E/I. H.C.I Pipe 100mm dia
58H.C.I Pipe 75mm dia
59Supplying and fixing H.C.I fittings of approved make confirming to I.S.S. 1729 including supplying nails and bobines lead and yarn from making lead caulked joints including earth work or providing scaffolding as the case may be all complete as per specification and direction of E/I.H.C.I single junction with door but without ear except socket 100 mm dia single junctions
60H.C.I fittings80 mm dia single junctions
61H.C.I Heal rest bend100 mm dia
6280 mm dia
63P- Trap - 100mm dia
64100mm dia
6580mm dia
66100mm dia
6780mm dia
68100mm Floor trap with gratings
69Nortorn patent H.C.I - Cowel100mm
70Making holes in walls for laying H.C.I pipes and restoring the same after laying as per specification and direction of E/I.
71Supplying materials and labour for painting the exposedH.C.I pipes and fittings with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per speficiation and direction of E/I100 mm dia
72Painting H.C.I pipes80 mm dia
73Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3(1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets
74Making Soakpit of 2.5M dia 3M deep with 45x45 cm dry brick honeycomb do all complete job as per direction of EI
75Point Wiring in PVC Conduit, with Modular type Switch:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required.Group C
76Wiring for twin control light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with 2 way modular type switch, modular plate, suitable size of GI box etc as required.
77S/F Ceiling Rose :-
78S/F Modular type electronic fan regulator :- Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required.
79Supply, fitting, fixing and testing of 1200mm Sweep, double ball-bearing, 2 canopy ceiling fanincluding connection with 1.5 sq mm copper wire, down rod all accessories as required.
80Supply of 300 mm, 230V A.C exhaust fan.
81Supplying and fixing single wall mounted 18/22 watt LED type batten fitting complete with electronic driver and LED tube etc directly on wall/ ceiling including connections with 1.5 sq.mm FR PVC insulated copper conductor and earthing the body etc. as required.
82Supplying and fixing Surface mounted 18/20 watt LED downlighter complete with integrated electronic driver & LED directly on ceiling including connection with 1.5 sq.mm FR PVC insulated copper conductor cable and earthing the body etc. as required.
83Supplying and fixing batten/ angle holder including connection etc. as required.
8415/16 Watt LED Bulb
85LED FLOOD LIGHT 75/80W
86S/F light plug point with modular type accessories :-Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc, as required.
87S/F Modular type Switch/ Socket (15/16 amps):-Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
88S/F Modular type Switch / Socket:-Supplying and fixing following modular type switch / socket on the existing modular plate and switch box including connections butexcluding modular plate etc as required.5/6 amps switch
89S/F Modular type blanking plate :-Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required.
90Copper earth pipe electrode :-Earthing with G.I. earth pipe 4.5mtr. long 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt as required.
91P/F 25mm x 5mm copper earth strip in surface/ recess :-Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc., as required.
92S/L 25 mm x 6 mm G.I. earth strip in ground :-Supplying and laying 25 mm X 6 mm G.I strip at 0.50 metre below ground as strip earth electrode, including soldering etc.
93P/F G.I. lightning conductor finial :-Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
94G.I. earth plate electrode :-Earthing with G.I. earth plate 600mm x 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
95P/ F G.I. Lightning conductor tape in horizontal run :-Providing and fixing G.I. tape20mm x 3mm thick on parapet or surface of wall for lightning conductor completeetc. as required (horizontal run).
96P/ F G.I. Lightning conductor tape in vertical run :-Providing and fixing G.I. tape20mm x 3mm thick on parapet or surface of wall for lightning conductor completeetc. as required (vertical run).
97Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
98Supply of following sizes and core PVC/XLPE insulated, PVC sheathed armoured electrical cable with aluminium conductor for working voltage upto 1.1 KV etc as required.3.5c x 95 sq.mm
9911 KV cable laying upto 120 sq.mm. in same trench :- Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
1001.1 KV Cable End Termination:-Supplying and making indoor cable end termination with brass double compression gland and aluminium lugs for following size of PVC insulated XLPE Al. Ar. Cable of 1.1 KV grade as required.3.5c x 95 sq.mm (45mm)
101Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm
102Supplying and fixing following way three pole & neutral ,sheet steel, MCB distribution board, 415 volts, onsurface /recess, complete with tinned copper bus bar, neutral bus-bar, earthbar ,dinbar, interconnections, powder painted including earthing etc. as required.4 Way (4+12) Double Door, Horizontal type
1036 Way (4+18) Double Door, Horizontal type
104S/F \"C\" series, MCB:-Supplying and fixing following 240 volts, \"C\" series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. As required.40 amps TPN
1056/32 amps DP
106S/F TPN RCCB Supply and fixing following rating, TN&N, (three phase and neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
107Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit.4R X 6 sq. mm + 2R x 6 sq.mm Earth Wire
1084R X 10 sq. mm + 2R x 10 sq.mm Earth Wire
109Wiring for light/ power plug with 2X4 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1Nos 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.
110Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit. 2R X 2.5 sq. mm + 1R x 2.5 sq.mm Earth Wire(Switch Boards)
111200/150 mm dia deep bore well supplying ll material labour and tools and equipment for drilling 200/150 mm dia bore well in any kind of sell rock by using DTH super rig machine and bell hammer technology inclusive of molillisation de molillisation of rig air compressor all assesseries tools and plant labour etc., all compete job inclusive transportation charges etc.From 0.0M to50.0 MbelowG.L.
112From 51.00 M to 130.00 MbelowG.L.
113Supplying,tools tackels & lowering of 200mm dia MS Erw Casing Pipe Of 6mm wall thickness including welding charges , cost of Pipe etc including all taxes, vat, Exciseduty,freight charges with inspection charges etc as applicable,etc all complete job
114Development of tube well in accordance with IS 2800 to establish maximum rate of usable water do all complete job as per direction of EI
115Supplying and fitting M.s.Capover200 mmdiacasingpipeasper directionofE/I. forsafety ofdrilling boreincludingprovidingofguard forsafetyofthesame tillreturnedfinal.
116Providing MS clamp of required dia to top of casing do all complete job as per direction of EI
117Suppling & commissioning of 2 HP submersible pump of reputed made ISI marked suitable for 200 mmx150mm dia tube well and head of 100 m. with lowering 50 mm dia column pipe 60 m. 4 sq. mm. finolex cable with panel board main switch, starter voltmeter aminator, on off switch HRC fuse unit, lighting arrangement. as per building specification and direction of Engineer Incharge
118Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes ,royalty etcall complete job as per direction of E/I.
119Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etcall complete job as per direction of E/I.
120Providing and fixing lowering 50 mm dia column pipe complete as per direction of Engineer in Charge. External work50 mm
121Sand
122Chips
123Cement
124Steel
125Bricks
126GST@18%
127LABOURCESS 1%

AI Tender Summary

OUR REF NO 37406238
AUTHORITY Government Departments
TENDER VALUE 55.49 Lakhs
LAST DATE 03-05-2023
Authority
Authority Name Rural Development Department
Work Description Tender For Construction Of Health Sub- Center, Madgi In Dulmi Block, Dist- Ramgarh.
Basic Detail
Tender No RDSD/RGH/02/HSC/06/2023-24
Bidding Type Tender
Location
City dulmi
State Jharkhand
Key Dates
Publish Date 26 Apr 2023
Submission Date 03 May 2023
Open Date 06 May 2023
Finance
Tender Value 55.49 Lakhs
Tender Fee 10000
EMD 1.11 Lakhs
Exemption Not Available
Document List
a80c3c62-4b07-4bba-9728-f56b796c0b86.html
BOQ_94324.xls
SBD.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 26, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
May 03, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 06, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

a80c3c62-4b07-4bba-9728-f56b796c0b86.html

xls

BOQ_94324.xls

pdf

SBD.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders