| 1 | Footpath Lighting |
| 2 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 3 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 4 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). |
| 5 | OD281331/2022-2023:Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete .Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 6 | OD281332/2022-2023:Supply Conveyance, installation, testing and commissioning of 20W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 7 | OD281333/2022-2023:Supply, conveyance installation testing and commissioning the light fittings of following types complete with all accessories andlamps etc. directly on wall or ceiling withand giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture (PHILIPS 20W LED Slimline Tubelight/equivalent) |
| 8 | OD281334/2022-2023:Supply conveyanceinstallation testing commissioning of Decorative Pole 3 meter height above the ground level made out of GI, tubularpole ‘T’ washed and premièred (ASTM A123) having two section section, bottom section of minimum 1000mm with base dia of 114mm and upper section of minimum 2000mm with dia of 76mm. The pole shaft shall be as per IS 1161.The pole shall have castiron embellishments. The pole shall have base plate of dimension 200x200x12mm and with 4 Nos foundation bolts. The pole shall be with inbuilt junction looping box at bottom section with 32 A heavy duty 4 way connector for loop in & loop out and with MS base plate.The pole shall be suitable for wind loadings as per IS 875 part 3 1987. Design comply EN40 standard and basic wind speed169kmph.Pole should hot dip galvanized after 7 tank process to 65 microns to IS 2629:985/ IS 4759:1996 / IS 2633:1986. The Pole should be given with two coats of epoxy primer and above that itshould be given with polyurethane UV resistant coating (painted with avg. DFT of 70μm).The complete system should be hot dipped Galvanised.( Make Kesslec 3M Decorative RILA Pole GI with base plate/Crompton /Bajaj) |
| 9 | OD281352/2022-2023:SITC ofdecorative classic LED street lantern of system wattage of 40W, BIS certified with aluminaire body made of cast and spun aluminium, permanently sealed optical block (IP66)with heat sink and PMMA protector (IK07) fitted with a VentPlug pressure equalisation unit,fixed onto a hinged spun aluminium frame, control gear compartment accessed byloosening one screw for tool free opening and closing. Highly efficient temperatureresistant lenses for light distribution with several optical options providing excellentphotometry to optimally cater to different applications. Suitable for suspended mountingwith 1⁄2” BSP threaded pipe. Overall system efficiency of 120lm/W at correlated colourtemperature (CCT) of 3000K, colour rendering index (CRI) >70 and L70 rated lifetime of50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.95, with BIScertified potted driver having internal surge protection of 4/4 kV and an additional surgeprotection device (SPD) of 10/10 kV.: KESSLEC VALE 40W WWLED/ Porto post top 40W WW/ equivalent |
| 10 | OD281374/2022-2023:Supply ,conveyance, installation, testing and commissioning of 10W TWISTER IP65 rated LED Bollardwith robust design and efficient light fittings of all types LED inbuilt directly on existing concrete foundation with foundation bolts etc. and giving connectionswith required length of16/.20mm 3 core round copper conductor flex wire conforming torelevant ISS or with the original wiring ,making good the damage ,colour wash etc. as required(Crompton Greaves-model No.LBLTW-10-WW or equivalent make) -Garden light. |
| 11 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 12 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 13 | OD281336/2022-2023:Supply, conveyance & installation of Hensel make IP 66 / IP 67 weather proof 180x 130 x 77 mm cable junction Box ( KF 1006 B) with Terminal Set 2.5-6 sq.mm Copper |
| 14 | 9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 15 | 90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm |
| 16 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 17 | 90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size |
| 18 | 90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 19 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 20 | 90.14.3.1:Supply and providing heavy duty \"A\" section neoprene gasket in the panel boardA\" section neoprene beeding suitable for 1.60/ 2.00 mm sheet |
| 21 | 1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm |
| 22 | 90.6.4.1:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 1 Run |
| 23 | 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 24 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 25 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 26 | OD281337/2022-2023:Supply and fixing Time switch 240V AC DIN/BASE mounting(L&T J648B1-Analog version)/Hagerin the existing enclosure and giving connection as required- |
| 27 | OD281338/2022-2023:Supply and fixing 25A AC3, MNX 25, 2 Pole power contactor (L&T) conforming to IS/IEC 60947-4-1 & IEC60947-4-1 in the existing enclosure and giving connection as required- |
| 28 | OD281339/2022-2023:Supply and fixing 32A HRC fuse base with HRC fuse link and giving connection etc as required- |
| 29 | OD281340/2022-2023:Supply and fixing of Neutral link 32 A, 2 Way neutral links mounted on DMC/SMC base and giving connection etc as required. |
| 30 | 90.16.1.10:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG) |
| 31 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 32 | 90.16.2.3:Supply and laying of the following sizes of B class GIpipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.32 mm dia G.I pipe ( medium class) |
| 33 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 34 | OD281341/2022-2023:Supply and providing earth lead from the test joint to the earth electrode using the following sizesof conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.25 mm X 5 mm G.I. strip |
| 35 | OD281342/2022-2023:Supply and providing test joint for the earthing system using 2 Nos of the following sizesof strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2 x 25 x 5 mm GI strip |
| 36 | OD281343/2022-2023:Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required. 25x6 mm brass nut and bolt |
| 37 | OD15323/2023-2024:Supply and fixing of Danger 415 V, 150 x 100 mm aluminium anodised legend plates as required. |
| 38 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 39 | OD281344/2022-2023:Hire and Labour charges for Conreate core cutting |