Military Engineer Services-MES has published Tender For Special Repair Of Summer Appliances Against Ber Items At Command Hospital (Wc) Chandimandir. Submission Date for this Tender is 16-05-2023. Air Conditioner Tenders in chandimandir Haryana. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 09-May-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 16-05-2023 |
Sl. No. | Item Description |
1 | Taking out unserviceable/BER refrigerator of capacity up to 310 Litres, electric driven, 230V, Single phase,after disconnecting all incoming and outgoing electric connections and depositing in AGE E/M (U) CH store, complete all as specified and directed. |
2 | Supply and fixing refrigerator, electric driven, 230V, Single phase, of capacity up to 190 Litres, BEE 3 star rating inclusive all necessary connection & Testing, complete all as specified and directed. |
3 | Supply and fixing refrigerator, electric driven, 230V, Single phase, of capacity 290 Ltrs. BEE 3 star rated inclusive all necessary connections & Testing, complete all as specified and directed. |
4 | Taking out unserviceable/BERWater coolers, electric driven, 230V, Single phase of capacity up to 180 Ltrs after disconnecting all incoming and outgoingelectric and water pipe lineconnections and making good all disturbed surfaces as per existing anddeposiing to AGEE/M (U) CHstore, complete all as specified and directed. |
5 | Supply and fixing water cooler, electric driven, 230V, Single phase, having storage capacity of 40 Litres and nominal cooling capacity of 40 Litres per hour, complete including proper water draining system, UPVC 20 mm water connection, brass stop cock, electric connection with plug and socket, RO Connection to water cooler, etc omplete all as specified and directed. |
6 | Supply and fixing water cooler electric driven, 230 V, Single phase, having storage capacity of 120 litres and nominal cooling capacity of 60 litres per hour, complete including proper water draining system, UPVC 20 mm water connection, brass stop cock, electric connection with plug and socket, RO Connection to water cooler etc, complete all as specified and directed. |
7 | Supply and fixing water cooler electric driven, 230V, Single phase, having storage capacity of 80 litres and nominal cooling capacity of 40 litres per hour, complete including proper water draining system, UPVC 20 mm water connection, bras stop cock, electric connection with plug and socket, RO Connection to water cooler etc, complete all as specified and directed. |
8 | Supply and fix water cooler electric driven, 230V, Single phase, having storage capacity of 150 Litres and nominal cooling capacity of 150 Litres per hour. complete including proper water draining system, UPVC 20 mm water connection, brass stop cock, electric connection with plug and socket, RO Connection to water cooler etc, complete all as specified and directed. |
9 | Taking out unserviceable/BERwindowtypeair conditioners including indoor and outdoor unit, electric driven, 230V, Single phase of capacity1.5 TRafter disconnecting all incoming and outgoingelectric,drain water pipe line, cable copper pipe line connections and making good all disturbed surfaces as per existing anddeposit to AGEE/M (U) CHstore, complete all as specified and directed. |
10 | Supply and fixing room window type air conditioner, electric driven, 230V, Single phase,cooling capacity 4500 K Cal per hour (1.5 Ton ), BEE 5 star rating, complete including modification of existing wall opening, plaster and surface finishes as per existing,proper water draining system with PVC pipe of size 25 mm bore, front portion around the AC covered with 6 mm thickwaterproofing sheet,electric connection with plug and socket, inclusive of tacking out old wiring ,complete all as specified and directed. |
11 | Supply and fixing room window type air conditioner, electric driven, 230V, Single phase,cooling capacity 6000 K Cal per hrs (2 Ton ), BEE 3 star rating, complete including modification of existing wall opening, plaster and surface finishes as per existing,proper water draining system with PVC pipe of size 25 mm bore, front portion around the AC covered with 6 mm thickwaterproofing sheet,electric connection with plug and socket, inclusive of tacking out old wiring ,complete all as specified and directed. |
12 | Taking out unserviceable/BER Splittypeair conditioners, electric driven, 230V, Single phase of capacity up to2 TRafter disconnecting all incoming and outgoingelectric,drain water pipe line, cableconnections and making good all disturbed surface as per existing anddeposit to AGEE/M (U) CHstore, complete all as specified and directed. |
13 | Supply and fixing air cooled split unit air conditioner, electric driven, 230V, Single phase, cooling capacity 1.5 TRBEE 5 star rating, complete including proper water draining system with PVC pipe of size 25 mm bore, electric connection with plug and socket inclusive taking out old wiring, new MS Sheet power coated stand for outdoor unit, Copper pipe line connection with insulation from indoor unit to outdoor unit, cutting chases in wall etc and making good all disturbed surfaces as per existing surface finished, complete all as specified and directed. |
14 | Supply and fixing air cooled split unit air conditioner, electric driven, 230V, Single phase, cooling capacity 2 TRBEE 5 star rating, complete including proper water draining system with PVC pipe of size 25 mm bore, electric connection with plug and socket inclusive taking out old wiring, new MS Sheet power coated stand for outdoor unit, Copper pipe line connection with insulation from indoor unit to outdoor unit, cutting chases in wall etc and making good all disturbed surfaces as per existing surface finished, complete all as specified and directed. |
15 | Material and labour for Sub main wiring with 2x2.5 Sqmm +1x2.5 Sqmm single core flame retardant PVC insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade FRLS PVC concealed conduit ISI marked with all accessories on walls and making good the disturbed surfacesincluding all conduits fittings, clamps guttyetcfor earth DBs and boxes with proper thimbles, complete all as specified and directed.NOTE:- For payment purpose 2 length of 2.5 Sqmmand 2.5 Sqmm one lengthwill be measured as one running metre. Cutting chases shall be measured and paid separately under relevant item. |
16 | Material and labour for Sub main wiring with 2x4 Sqmm +1x4 Sqmm single core flame retardant PVC insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade FRLS PVC concealed conduit ISI marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps gutty etc for earth DBs and boxes with proper thimbles complete all as specified and directed. Note: For payment purpose 2 length of 4 Sqmm and 4 Sqmm one length will be measured as one running metre. Cutting chases shall be measured and paid separately under relevant item. |
17 | M&L for cutting chases, pinning in Stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cuttingexc. 10 cm girth complete all as specified and directed. |
18 | Supply and fixing Sheet metal enclosures with Single Pole andneutralenclosure withtwo pin and earth plug sockets controlled by one NoMCB SP rating 20 Amps , 240 Volts grade, complete complete all as specified and directed. |
19 | Supply and fixing Copper pipe (Heavy grade) 1/2" for liquid line including fittings, complete all as specified and directed. As per existiing site. |
20 | Supply and fixing Copper pipe (Heavy grade) 1/4" for suction liquid line including fittings, complete all as specified and directed. As per existiing site. |
21 | Supply and fixing Copper pipe (Heavy grade) 5/8" for suction line including fittings, complete all as specified and directed. As per existiing site. |
22 | Supply and fixing Copper pipe (Heavy grade) 3/8" for suction line including fittings, complete all as specified and directed. As per existiing site. |
23 | Supply and fixing of insulation foam for copper pipe of size 1/2", complete all as specified and directed. |
24 | Supply and fixing of insulation foam for copper pipe of size 1/4", complete all as specified and directed. |
25 | Supply and fixing of insulation foam for copper pipe of size 5/8", complete all as specified and directed. |
26 | Supply and fixing of insulation foam for copper pipe of size 3/8", complete all as specified and directed. |
27 | Supply and fixing of PVC flexible pipe 25mm dia & 3 Metres long complete inclusive testing, complete all as specified and directed. |
28 | Supply and fixing of factory madeMS stand for housing outdoor unit complete with fixing in wall with hinges, nuts and bolts, complete all as specified and directed. |
29 | Supply, layingand fixing ofcopper cable 3 core, 2.5 Sqmmdia, PVC insulatedcomplete inclusive all fittings and testing, complete all as specified and directed. |
30 | Supply, layingand fixing ofcopper cable 4 core, 2.5 Sqmmdia, PVC insulatedcomplete inclusive all fittings and testing, complete all as specified and directed. |
31 | Supply and fixing of PVC water drain pipe 25mm dia complete inclusive all fittings and testing, complete all as specified and directed. |
32 | Supply and chargingof Gas R-22/134a or other recharging gas as specified by manufacturing company for AC after testing in any type of AC inclusive testing of performance of AC, complete all as specified and directed. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail