Road And Building Department-RBD has published Tender For Shifting Of 11 Kv Line By Laying Of Ug Cable With Rmu Of Feeder-1 And Vss Nagar From Arss Chhowk To Odcl Chhowk Due To Construction Of Railway Over Bridge Bhubaneswar For The Year 2022-2023. Submission Date for this Tender is 09-05-2023. Feeder Pillar Tenders in bhubaneswar Odisha. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Laying of 3Core, 400sqmm, UG cable with spare cable(0.72KmX2)= 1.44Km Installation of 11KV 4way RMU-1No. Supply of 11kV, 3Core, 400sqmm, XLPE insulation armoured UG cable (SC rating of cable in kA- 37.7kA and SC rating of Armour in kA- 15kA) |
2 | Supply of Straight through jointing kits Heat Shrinkable type suitable for 11kV, 3Core, 400 sqmm, Aluminium UG cable for 3Core (Set) |
3 | Supply of Indoor termination kits Heat Shrinkable type suitable for 11kV, 3Core, 400 sqmm, HT UG cable for 3Core (Set) |
4 | Supply of Outdoor termination kits Heat Shrinkable type suitable for 11kV, 3Core, 400 sqmm, HT UG cable for 3Core (Set) |
5 | Supply of HDPE PE 80-PN8 pipe of 160mm diameter (for 400sqmm HT cable laying) |
6 | Supply of 11kV RMU 4 Way, 2 Iso & 2 Brk 630A (LLVV) |
7 | Earthing Conductor: 50X6 mm (2.4kg./mtr.) GI Flat for equipment, structure etc.) |
8 | Pipe Earthing 40mm. GI Pipe |
9 | Supply of End Connector |
10 | Supply of standard FRTU |
11 | Earth work excavation of soil |
12 | Earth work excavation of hard rock |
13 | Back filling with excavated soil outside and above the trench |
14 | Damage of asphalt/tar road and other utilities and reconstructing to bring to its original shape after laying of cable in open trench (1mtr. width) |
15 | Prefabricated RCC foundation of 11kV RMU |
16 | Supply of GI Fencing with Gate around each RMU |
17 | Installation ofEarthPit, Charcoal, Salt etc. including construction of earthing chamber (Size: 2"x2") and RCC slab cover |
18 | Supply and erection of GI Pipe of dia. 150mm, Class-B (8Mtr.) |
19 | Supply and Erection of Cable Route Marker along the cable route at an interval of 30mtrs with civil works |
20 | Installation of 11KV 4way RMU-1No. Description of itemsLaying, Commissioning, Testing of 11kV, 3core, 400sqmm, aluminium, XLPE insulation armoured (extruded type) UG cable by open trench method. |
21 | Erection of Straight through jointing kits Heat Shrinkable type suitable for 11kV, 3Core, 400sqmm, aluminium UG cable kits for 3core (set) |
22 | Erection of Indoor termination kits Heat Shrinkable type suitable for 11kV, 3Core, 400sqmm, aluminium UG cable kits for 3core (set) |
23 | Erection of Outdoor termination kits Heat Shrinkable type suitable for 11kV, 3Core, 400sqmm, aluminium UG cable kits for 3core (set) |
24 | Laying of 160mm dia PE 80-PN8, HDPE pipe inside open trench. |
25 | Erection of 11kV RMU 4 Way, 2 Iso & 2 Brk 630A (LLVV) |
26 | Erection of end connector and accessories for OFC connection at RMU. |
27 | Erection, Commissioning, Testing of Standard FRTU 4 Way with FRTU networking equipment consisting of Fibre Optic Switch (Mono mode alongwith associate LIU unit for connection of FO Cable for 3 Way and 4 Way RMU. |
28 | Construction of 11KV Line DP with AB Switch -8Nos. Description of Materials WPB 160x152 (11Mtr. Long, 30.44KG/Mtr.) |
29 | Top Channel 100X50X6mm, 9.56 KG/Mtr., each channel length 3 mtr., 2 no"s channel required =( 2x9.56x3) |
30 | Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no"s required = (6x2.36x0.280) |
31 | AB switch Mounting Channel 75X40X4.8mm, 7.14KG/Mtr, each channel length 3 Mtr., 2 no"s channel required =( 7.14x3x2) |
32 | AB Switch Side Support Channel 100X50X6mm,9.56 KG/Mtr., each channel length 0.35 mtr., 2 no"s channel required =( 9.56x2x0.35) |
33 | Channel Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each channel length 0.8 Mtr., 1 no"s channel required =( 7.14x0.8x1) |
34 | Double Pole Belting Channel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 3.0 Mtr., 4 no"s channel required =( 7.14x3x4) |
35 | 50x50x6mm.GI Bracing Angle, 4.5Kg./mtr., each angle length 3.512 mtr., 4 nos angle required = (4.5x3.512x4) |
36 | Danger Plate, 2 no"s. |
37 | Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no"s = (2x0.59x0.510) |
38 | H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no"s qty. required ( 1 Pair) |
39 | H.T. Stay set (Complete ) |
40 | H.T. Stay Insulator Type-C |
41 | 7/10 SWG Stay Wire 15kg /stay |
42 | Gi Pipe Earthing 40mm. 3 Mtr. Long |
43 | 50x6mm GI Flat for earthing, 2.36kg/mtr., (12.5 Mtr. For L.A, 3 Mtr for AB Switch Body, 2.5 mtr. For mesh formation and 2.5 mtr. For raising)= 20.5x2.36 |
44 | GI barbed wire anticlimbing device 3 Kg. Per support, 2 no"s qty. required=(2x3kg) |
45 | Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no"s = (8x0.59x0.510) |
46 | Lightning Arrester(12KV,10KA) (Station Class,class-2) |
47 | AB Switch (11KV,400A.3pole,50Hz) |
48 | 11 KV pin insulator polymer |
49 | H W fitting(B&S) 70KN, 3Bolt |
50 | Disc insulator (B&S) 70 KN polymer |
51 | PG Clamp for 55 sq.mm AAA conductor |
52 | GI Nut , Bolt & Washer of different sizes (13.718 Kg each DP with AB Switch) |
53 | Black Paint |
54 | Yellow Colour Paint for Background |
55 | Dismantling of 11KV RS joist Pole-10Nos. Dismantling of 11KV Line- 400Mtr. Dismantling 11KV Line DP-2No.Dismantalling of RS Joist Pole |
56 | Dismantalling of V Cross Arm |
57 | Dismantalling of conductor |
58 | Dismantalling of Existing Line DP(N.B.:- Salvage value of dismantled materials amounting to Rs.14116 will be deducted from contractor"s bill.) |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy