Tender For Tourism Development Works Of Maa Baghwati Temple At Gram-Bashaon, Tehisil- Pindra, Distt.- Varanasi (U.P.)
Tender Value
Ref. Documents
Estimated cost
Bid Submission
01 May 2023
0 days left
EMD
2.08 Lakhs
Bank guarantee accepted
Document Fee
17700
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
pindra → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Tourism Development Works Of Maa Baghwati Temple At Gram-Bashaon, Tehisil- Pindra, Distt.- Varanasi (U.P.)
BOQ
| Sl. No. | Item Description |
| 1 | TOURISM DEVELOPMENT WORKS OF MAA BAGHWATI TEMPLE AT GRAM-BASHAON, TEHISIL:-PINDRA, DISTT.- VARANASI (U.P.) |
| 2 | Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 3 | Filling of carted earth. |
| 4 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 5 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. |
| 6 | Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete. (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer\"s standard dilution) |
| 7 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. |
| 8 | As in item no. 6 above but for slabs (Using 1:1.5:3 Mix concrete) |
| 9 | As in item no. 6 above but for Beam (Using 1:1.5:3 Mix concrete) |
| 10 | As in item no. 6 above but for Column (Using 1:1.5:3 Mix concrete) |
| 11 | As in item no. 6 above but for Footing (Using 1:1.5:3 Mix concrete) |
| 12 | M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 13 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) |
| 14 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 15 | Same as in item No. 11 abovebutin super-structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand) |
| 16 | Same as in item no. 14 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. |
| 17 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 18 | 15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. |
| 19 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 Coarse sand |
| 20 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1) 1 cement : 6 Coarse sand |
| 21 | Making grooves 10 to 12 X 12mm and upto 25 X 15 mm deep in plaster of the walls or in ceiling vertically or horizontally as required. |
| 22 | Supply & fixing 6mm China white glazed tiles in flooring or in skirting or dado laid with 1:3 Cement and approved coarse sand mortar finished with whitecement slurry, jointing and polishing complete, including supply of all materials, labour and Tool & plants. |
| 23 | Supply & fixing 6mm China white glazed tiles in flooring or in skirting or dado laid with 1:3 Cement and approved coarse sand mortar finished with whitecement slurry, jointing and polishing complete, including supply of all materials, labour and Tool & plants. |
| 24 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm (Flooring) |
| 25 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm (Skirting) |
| 26 | Supply & fixing of Kota stone in flooring 25 mm thick and joint filled with 1:2 cement and coarse sand with approved colouring materials to be given an even shade with 12 mm base coat (bedding) of 1:2 cement & coarse sand mortar and polished by hand or machine and finally finished with french manson polish or other approved polish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. |
| 27 | Supply & fixing 10 to 12 mm thick kota stone tiles in skirting or dado laid with 1:2 cement and approved coarse sand mortar finished with in its cement colour slurry, jointing and polished of approved quality complete, including supply of all materials, labour, tools and plants etc. required for proper completion of the work. |
| 28 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Ordinary cement without any pigment |
| 29 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). |
| 30 | Providing and fixing of Flush doors commercial quality conforming to I.S. 2202 part-I (1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges, bolts locks, handles spring fitting with necessary screws to be supplied departmentally. 35 mm thick |
| 31 | M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work. Providing & fixing of hold fast for chaukhatsof doors and windows. |
| 32 | Providing & fixing of door / windows grill. |
| 33 | Z-Section steel windows (openable) |
| 34 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 35 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)[FOR DOOR CHAUKHAT] Fixing of Door, windows/ventilators chaukhats in position. |
| 36 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface) |
| 37 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 38 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (Ceiling) |
| 39 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 40 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 41 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 42 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete(a) 250 mm x 10mm |
| 43 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm |
| 44 | Providing & laying \"brick coba\" 12 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15 mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with aerelic cement concrete water water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30cm x cm and side wall parapet shall be mono tythic plaster wall upto 30 cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonary coba with top finished plaster mixed with acelic water proofing compound @ 2% by weight & including S/o all material, labour, T & P etc complete for proper completion of work. |
| 45 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. |
| 46 | Same as item 41 above but on new wood surface. |
| 47 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 48 | Construction of drain alongwith apron. |
| 49 | Electrification work |
| 50 | Wiring point for light with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in PVC conduit with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthing wire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash |
| 51 | Wiring point for two ways light with 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash |
| 52 | Wiring point for fan with 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash |
| 53 | Wiring point for exhaust fan with 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash |
| 54 | Wiring point for plug 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & socket etc, complete in all respect including matching colour wash. |
| 55 | Supplyfixingand concealing of25mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of the work as per directions and to the satisfaction of engineer in charge. ( T.V. /Telephone) |
| 56 | Supply & wiring of submains with two number2.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick)PVC conduit with 1 Number 1.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduitcomplete in all respect. |
| 57 | Supply & wiring of submains with two number4 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick)PVC conduit with 1 Number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduitcomplete in all respect. |
| 58 | Supply and wiring of submain with 4 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in32 mm dia heavy duty (2mm thick ) PVC conduitpartly concealed in wall and partly laid in slab along with reinforcement befor concreting with two number 10 SWG copper earth contunity wire including colour wash etc. complete in all respects. |
| 59 | Supply & fixing of single wall bracketon matching M.D.F.E.G.boardbase etc. complete in all required.CAT-AAA |
| 60 | Supply & fixing ofrecess/Surface/Pendent mounting round 10 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects. Cat. AAA |
| 61 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect.CAT-AAA |
| 62 | Supply and Fixing of LED Tube Light batten suitable for up to 1X22 watt LED tube light on surface complete in all respect.CAT-AAA |
| 63 | Add for fixing of tubefittingaspendent with twonumber 19 mm dia. 16gaugerigid steelconduitdoublechecknuts : spring loaded flanges or M.S. hook fabricatedfrom 25mm x 3mm flatiron dulygroutedinthe ceiling upto 3.5 height of ceiling upto3.5 height of ceiling, includingpaintingwith synthetic enamel paint. alongwith supplyof all materials, labour, T & Petc.required for proper completion of work. |
| 64 | Supply of Ceiling Fan with motor of A.C. Permanent insulation capacitor rating confirming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated volage 220/240 volts, 50 Hz, 1-ph A.C.the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system. BEE 5 Star rated-1200mm sweep |
| 65 | Supply and Fixing ofservice bracket of 50mm. Dia 4 meter long fabricated from class \"\"B\"\" G.I. pipe complete with two bend, socket, wall clamps. 7/3.15 mm G.I. stay wire, stay insulators etc..complete in all respects. |
| 66 | Supply and fixing of factory wired integral LED flood light fitting having diecast aluminium housing built with driver set suitable for 140 to 150 watt confirming to IP 66 protection complete in all respect. CAT-AAA |
| 67 | Supplyand burying safe earthing Electorde T-19 (HotDip Galvanized), Length 2000 mm, outer pipe 50mm, inner pipe 25,terminal Dia 12mm ,outer G.I.pipe of 16 swg and inner GI pipe of 12swg withHotDipGavanized up to 100 mirconfilled with crystalline conducative mixture (CCM) having anti corrosive & conducative property with 50 kgs activated soil (BFC) capable ofreducing the soilresistivitywith good mixture ofretaning capacity along with 30 cm squre C.I. frame with hinged cover & masonryhousing (from electode terminaltoswitchboard , cost of 25 x 3 G.I. strip will be extra) Make:As approved in U.P.P.W.D. & C.P.R.I. Certified |
| 68 | Supplying & Laying of 25mmx3mm G.I. Strip from earth electrode in ground as required complete in all respects. |
| 69 | Supply & fixing of two number 8 SWG G.I. wire for earthing purpose as required complete in all respects. |
| 70 | Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve 6 - 32 amps.Cat. A |
| 71 | CAT ASupply and fixing of 63 Amp. 4 Pole MCB (10KA) |
| 72 | Supply and fixing of surface/ flush mounting 8 way TPN distribution board with additional metal doorwithout MCB complete in all respect, as directed at site by Engineer Incharge. CAT A |
| 73 | Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6sqmm cables, including tapping with insulating tape,etc. complete in allrespects. |
| 74 | Supply and fixing of single pole MCB blanking plate CAT A |
| 75 | Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250 Volt flush type universal modular socket switch on concealedM.S. box including supply of all material, labour T & P etc required for proper completion of work. |
| 76 | Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects. |
| 77 | Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects. |
| 78 | Supply & fixing hexagonal/Round G.P. Fan box of approved make made up of 1.0 mm thick ISI marked G.P. Sheet spot welded four to Eight holes of 25.4mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screwed fitted with 300mm round zink coated M.S. Bar x 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material labour, T & P etc required for proper completion of the work. |
| 79 | Supplyfixingofelectronic fan regulator (Modular) 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. |
| 80 | Supply and fixing of surface/ flush mounting 6 ways V TPN distribution board with additional metal doorwithout MCB complete in all respect, as directed at site by Engineer Incharge. CAT A |
| 81 | Supply and fixing of 160 Amp 4 pole MCCB(25KA) Theramal Magnetic reaease Cat. A |
| 82 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc.(A) 6 sqmm 2 core |
| 83 | 10 sqmm 4 core |
| 84 | 25 sqmm 3.5 core |
| 85 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Inchage.(a) 6 sqmm 2 core |
| 86 | 10 sqmm 4 core |
| 87 | 25 sqmm 3.5 core |
| 88 | Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. (a) 6 Sq.mm |
| 89 | 10 Sq.mm |
| 90 | 25 Sq.mm |
| 91 | Supply and fixing 100 AMPfour pole Moulded case type on load change over switch with enclosure(also suitable for panel mounting with extra cost of bus bar) including the cost of labour, T & P , painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge.- |
| 92 | Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 93 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. Telephone socket outlet |
| 94 | TV antenna socket outlet |
| 95 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 75mm X 75 mm X 60mm Deep |
| 96 | Supplying and fixingfollowing size/modules, GI box along with modular base& cover plate for modular switches in recess etc as required. (a) 1 or 2 Module (75mm X 75 mm) |
| 97 | Extra for fixing the louvers / shutters complete with frame for exhaust fans of all sizes. |
| 98 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 99 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. (a) 100 mm Dia |
| 100 | Supplyof AC 230/250 Volts, 50 Hz 60 w 1325 rpm exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required-Make: USHA Cat No. TURBO L.D. JET DLX (a) 300mm sweep. |
| 101 | Water Supply & Sanitary works |
| 102 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required (a) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 103 | Same as above but for European type W.C. pan with white plastic seat and lid |
| 104 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require(a) White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. |
| 105 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipea) 32mm dia |
| 106 | b) 40mm dia |
| 107 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 108 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. 15mm nominal bore |
| 109 | Providing and fixing Toilet paper holder a) C.P. brass |
| 110 | Providing and fixing CP Brass Single lever lelephonic wall mixture of quality & make and as per thedirection of Enginer-in-charge. a) 15mm dia nominal dia. |
| 111 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms |
| 112 | Providing & fixing 600x120x5 mm glass self with edges round off, supported on anodiesd aluminium angle framewith C.P. brass bracket and guard rail complete fixed with 40 mmlong screws, rawl plugs etc, complete. |
| 113 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. a) 110mm diameter |
| 114 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.a) 110mm |
| 115 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. a) 110mm |
| 116 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 117 | Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size)around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground)100/75 mm diameter |
| 118 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. (a) 75 mm O.D. |
| 119 | 110 mm O.D. |
| 120 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. |
| 121 | Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. (a) Size 75 mm |
| 122 | Size 110 mm |
| 123 | Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735.(a) Size 75x75x75 mm |
| 124 | Size 110x110x110 mm |
| 125 | Supply and fixing of UPVC S.W.R. plain Y confirming to IS-14735.(a) Size 75 mm |
| 126 | Size 110 mm |
| 127 | Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. (internal work) xposed on wall 25mm dia nominal bore |
| 128 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. 25mm dia nominal bore. |
| 129 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work)Exposed on wall(a) 20mm dia nominal outer dia pipes |
| 130 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. (a) 15mm dia nominal outer dia pipes |
| 131 | 20mm dia nominal outer dia pipes |
| 132 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. a) 15mm nominal bore |
| 133 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 a) 15mm nominal bore |
| 134 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 a) 15mm nominal bore |
| 135 | Providing & fixing C.P. Brass extension nipple(size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 136 | Providing and fixing gun metal gate valve with wheel of approved quality.(a) 20 mm dia nominal bore |
| 137 | 25mm dia nominal bore |
| 138 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. (A)25 mm nominal bore |
| 139 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 140 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
| 141 | Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 100mm diameter |
| 142 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 100mm diameterS.W. Pipe |
| 143 | Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete.150mm diameter |
| 144 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design(a) 150 mm.dia. RCCPipes |
| 145 | Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design150 x 100 mm. size P type With Sewer bricks conforming to IS : 4885 |
| 146 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard designInside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 |
| 147 | (i) For Sewer Line Extra for depth of man hole size 90x80 cm |
| 148 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar |
| 149 | External Sewarage & water supply |
| 150 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
| 151 | Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete.150mm diameter |
| 152 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm.dia. RCCPipes |
| 153 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard designInside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 (i) For Sewer Line |
| 154 | Extra for depth of man hole size 90x80 cm |
| 155 | Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. |
| 156 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250mm diameter |
| 157 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. not exceeding 80mm dia. |
| 158 | Provding and fixing C.I. Double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if required will be paid separately. 50 mm dia |
| 159 | Provding and fixing gun metal non return valve of approved quality (screwed end) 80 mm nominal bore a) Horizontal |
| 160 | Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work) 80mm nominal bore. |
| 161 | 65mm nominal bore. |
| 162 | 50mm nominal bore. |
| 163 | 25mm nominal bore. |
| 164 | Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work. 80 mm diameter pipe |
| 165 | 65mm diameter pipe |
| 166 | 50 mm diameter pipe |
| 167 | 25 mm diameter pipe |
| 168 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 80 mm nominal bore |
| 169 | 65 mm nominal bore |
| 170 | 50 mm nominal bore |
| 171 | 25 mm nominal bore |
| 172 | Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With F.P.S. bricks |
| 173 | Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for stop cock, withC.I. surface box 100x100x75mm(inside) with hinged cover fixed in cement concrete slab1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With F.P.S. bricks |
| 174 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm dia nominal bore |
| 175 | 50 to 80 mm dia nominal bore |
| 176 | Construction of Septic Tank(5.00x2.50x3.00mtr.) and Soak pit(2.50 mtr. Dia. & 3.00 Mtr. Depth) with including all complete. For Hall as per Detalied |
| 177 | Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD-2018-1131 (A) |
| 178 | Supply & fixing of CO2 type fire extinguisher,6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD-2018-1132 (A) |
| 179 | Construction of Boundry wall (ht.-1.80 mtr.) For Temple Campus with including all Complete & As per Detailed Estimate. |
| 180 | FRESCO PAINTING ON WALL with including all cleaning surface ,Putty painting Etc. all complete. |
| 181 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. |
| 182 | 40 mm thick rubbed stone flooring over 20 mm (average) thick base ofcement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick,side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixedwith pigment to match the shade of stone and pointing with same mortar with Edging of brick work & Base C.C. (1:4:8) with stone ballast inlding all complete. |
| 183 | Landscapping & Horticulture Works with Site devlopment including all complete. |
| 184 | P/Fixng of Solar light with led & Automatic system including all complete. |
| 185 | G.S.T. Extra as per Applicable |
AI Tender Summary
Tender Timeline
Apr 24, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedMay 01, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMay 01, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender