Tender For Repair/Replacement Of Ceiling Fans, Exhaust Fans, Wall Mounted Fans, Pedestal Fans And Air Circulators Along With Allied E/M Works At Af Stn Suratgarh, suratgarh-Rajasthan

Military Engineer Services-MES has published Tender For Repair/Replacement Of Ceiling Fans, Exhaust Fans, Wall Mounted Fans, Pedestal Fans And Air Circulators Along With Allied E/M Works At Af Stn Suratgarh. Submission Date for this Tender is 22-05-2023. Air Circulators Tenders in suratgarh Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

37378626
Corrigendum : Tender For Repair/Replacement Of Ceiling Fans, Exhaust Fans, Wall Mounted Fans, Pedestal Fans And Air Circulators Along With Allied E/M Works At Af Stn Suratgarh
Open Tender
Indian
Rajasthan
suratgarh
22-05-2023

Tender Details

Repair / Replacement Of Ceiling Fans, Exhaust Fans, Wall Mounted Fans, Pedestal Fans And Air Circulators Along With Allied E / M Works At Af Stn Suratgarh

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-May-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-05-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/REPLACEMENTOF CEILING FANS, EXHAUST FANS, WALL MOUNTED FANS, PEDESTAL FANS AND AIR CIRCULATORS ALONGWITH ALLIED E/M WORKS AT AF STN SURATGARH
Sl. No. Item Description
1BOQ (REPAIR/REPLACEMENTOF CEILING FANS, EXHAUST FANS, WALL MOUNTED FANS, PEDESTAL FANS AND AIR CIRCULATORS ALONGWITH ALLIED E/M WORKS AT AF STN SURATGARH)
2Taking down unserviceable ceiling Fan of following sizes of any make dismantling cutting and removing of old burnt windings and rewinding with super enamelled copper winding wire of required size including allied insulation material, varnish, sleeves etc. greasing, oiling, re-assembling testing and refixing in the same position , complete all as specified and directed by the Engineer-in-Charge.
31200 mm sweep
41400 mm sweep
5All as perserial item no 1 above but Exhaust Fan of following size and any make.
6450 mm size
7300 mm size
8230 mm size
9All as perserial item no. 1 but wall Fan of following size and any make.
10450 mm size
11600 mm size
12All as per serial item no. 1 but Air circulator of following size and any make.
13450 mm size
14600 mm size
15750 mm size
16Supply and fixingin replacement of capacitor of 3.15 mfd including fixing complete and including necessary items such as sleeves etc, complete all as specified and directed by the Engineer-in-Charge. Make: EPCOS/HAVELLS
17S & F Step 0-4,electronic regulator for ceiling fan 1200/1400 mm sweep, 240 volts, 100 Watts humfree single pole in replacment ,complete all as specified anddirected by Engineer-in-Charge. Make : Legrand/Anchor /Plaza .
18Supply and fixing in replacement of bush / bearing ofsuitable size in ceiling Fan of following size, complete all as specified and directed by the Engineer-in-Charge. Make : NBC/ SKF.
19Ceiling Fan of 1200 mm sweep
20Ceiling Fan of 1400 mm sweep
21Supply and fixing in replacement of bush / bearing ofsuitable size in Exhaust Fan of following size, complete all as specified and directed by the Engineer-in-Charge. Make : NBC/ SKF.
22Exhaust Fan of 450 mm sweep
23ExhaustFan of 300 mm sweep .
24Exhaust Fan of 230 mm sweep
25Supply and fixing in replacement ofbush / bearing ofsuitable size in Air circulatorsFan of following size, complete all as specified and directed by the Engineer-in-Charge. Make : NBC/ SKF.
26Air circulator Fan of 450 mm sweep
27Air circulators Fan of 600 mm sweep
28Air circulators Fan of 750 mm sweep
29Supply and fixing in replacement of bush / bearing ofsuitable size in wallFan of following size, complete all as specified and directedbythe Engineer-in-Charge. Make : NBC/ SKF.
30Wall mountingFan of 450mm sweep
31Wall mounting Fan of 600mm sweep .
32Supply and fixing in replacement of Metallic clamps for hanging of ceiling Fan with bolts & nuts,,split pin etc., complete all as specified and directedbythe Engineer-in-Charge.
33Supply and fixing in replacement of Stator of Ceiling Fan of following size, complete all as specified and directed bythe Engineer-in-Charge.
34Ceiling Fan of 1200 mm sweep
35Ceiling Fan 1400 mm sweep
36Supply and fixing in replacement ofRotor of ceiling Fan of following capacity, complete all as specified and directed bythe Engineer-in-Charge
37Ceiling Fan of 1200 mm sweep
38Ceiling Fan 1400 mm sweep
39Supply and fixing in replacement ofPVC canopy for ceiling Fan (upper & lower)of following capacity, complete all as specified and directed bythe Engineer-in-Charge.
40Ceiling Fan of 1200 mm sweep
41Ceiling Fan of 1400 mm sweep
42Supply and fixing in replacement of Blade set for ceiling Fanof following capacity with boltsetc., complete all as specified and directed bythe Engineer-in-Charge.
43Ceiling Fan of 1200 mm sweep
44Ceiling Fan of 1400 mm sweep
45Supply and fixing in replacement of cast AluminiumBody cover for ceiling Fanof following capacity with boltsetc., complete all as specified and directed bythe Engineer-in-Charge.
46Ceiling Fan of 1200 mm sweep
47Ceiling Fan of 1400 mm sweep
48Supply and fixing in replacement of rubber reel/pad of suitable size for ceiling Fan of any size and make, complete all as specified and directed bythe Engineer-in-Charge.
49Supply and fixing in replacement ofMS down rodof length 450 mm for ceiling Fan of any size and make, complete all as specified and directed bythe Engineer-in-Charge.
50Spray painting with synthetic enamel paint of(shade as approved by Engineer – in – Charge) after preparation of old surface of ceiling Fan/ exhaust Fan of any make/model/sweep and marking MES No with synthetic enamel paint, complete all as specified directed bythe Engineer-in-Charge.
51Supply and fixing in replacement of Metallic Blade set for ExhaustFanof following sizewith boltsetc., complete all as specified and directed bythe Engineer-in-Charge.
52ExhaustFan of 450 mm sweep .
53ExhaustFan of 300 mm sweep .
54Exhaust Fan of 230 mm sweep
55Supply and fixing in replacement of Metallic louversfor ExhaustFanof following sizewith boltsetc., complete all as specified and directed bythe Engineer-in-Charge.
56ExhaustFan of 450 mm sweep .
57ExhaustFan of 300 mm sweep .
58Exhaust Fan of 230 mm sweep
59Taking down ceiling Fan of any size, any make fixed/hanged at different location in Air Force area, dismantling the Fan and servicing, greasing, oiling and cleaningcomplete and re-assembling the same including replacing split pins flexible copper cable of size 23/0.0076 twin core, 70cm long and refixing the ceiling Fan on the same location in original position, testing and commissioning of Fan for smooth running, as per entire satisfaction of Engineer-in-Charge. Note:- (i)Quoted rate by tenderer of any item of the schedule is inclusive of taking down the ceiling Fan from the position for carrying out servicing repair transportation to work shop & back, changing any component and re-fixing/hanging in position connecting and testing complete.
60All as perserial item No. 22 above but wall mounted Fan of any size and any make.
61All as per serial item No. 22 above but Exhaust Fan of any size and any make
62All as perserial item No. 22 above but Air circulator fan of any size and any make
63Taking down carefully aluminum point wiring (light, fans, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket, etc. and making good disturbed surface of wall/floor, etc. complete all as specified anddirected by Engineer-in-Charge. Note :- Temporary power supply shall be provided by contractor.
64M & L for Point wiring (surface) complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in including non metallic medium grade rigid PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories on the surface of walls/floors/ceilings and making good the disturbed surface, with and including sunken type pressed steel/welded MS terminal box 1.2 mm thick bakelite laminated sheet top cover 3 mm thick and 1.5 Sq mm copper earth continuity wire connected to earth dolly complete for the following , complete all as specified anddirected by Engineer-in-Charge. (a) One light/fan point controlled by one switch . Note : The disturbed surfacesof wall for concealing the wiring shall be make good by applying cement plaster, putty and colour wash etc matching with the existing surfaces.The rate for point wiring shall be deemed to include the cost of making good.
65All as per item No 27 above but one socket outlet 3 pin 5 Amp on same board.
66S & F Switch piano flush button single pole one way 5 amp 240 volts, including connecting and testing , complete all as specified anddirected by Engineer-in-Charge.
67S & F Socket outlet2 in 1 ,3 pin, 5 and 15 amps, flush type, 240 volts, including connecting and testing ,complete all as specified anddirected by Engineer-in-Charge.
68S & F Ceiling rose, surface bakelite, 65 x 50 mm, three terminals, including connecting and testing, complete all as specified anddirected by Engineer-in-Charge.
69Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary on serial page No 17 of tender documents.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,