Military Engineer Services-MES has published Tender For Repair/Replacement Of Ceiling Fans, Exhaust Fans, Wall Mounted Fans, Pedestal Fans And Air Circulators Along With Allied E/M Works At Af Stn Suratgarh. Submission Date for this Tender is 22-05-2023. Air Circulators Tenders in suratgarh Rajasthan. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 15-May-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 22-05-2023 |
Sl. No. | Item Description |
1 | BOQ (REPAIR/REPLACEMENTOF CEILING FANS, EXHAUST FANS, WALL MOUNTED FANS, PEDESTAL FANS AND AIR CIRCULATORS ALONGWITH ALLIED E/M WORKS AT AF STN SURATGARH) |
2 | Taking down unserviceable ceiling Fan of following sizes of any make dismantling cutting and removing of old burnt windings and rewinding with super enamelled copper winding wire of required size including allied insulation material, varnish, sleeves etc. greasing, oiling, re-assembling testing and refixing in the same position , complete all as specified and directed by the Engineer-in-Charge. |
3 | 1200 mm sweep |
4 | 1400 mm sweep |
5 | All as perserial item no 1 above but Exhaust Fan of following size and any make. |
6 | 450 mm size |
7 | 300 mm size |
8 | 230 mm size |
9 | All as perserial item no. 1 but wall Fan of following size and any make. |
10 | 450 mm size |
11 | 600 mm size |
12 | All as per serial item no. 1 but Air circulator of following size and any make. |
13 | 450 mm size |
14 | 600 mm size |
15 | 750 mm size |
16 | Supply and fixingin replacement of capacitor of 3.15 mfd including fixing complete and including necessary items such as sleeves etc, complete all as specified and directed by the Engineer-in-Charge. Make: EPCOS/HAVELLS |
17 | S & F Step 0-4,electronic regulator for ceiling fan 1200/1400 mm sweep, 240 volts, 100 Watts humfree single pole in replacment ,complete all as specified anddirected by Engineer-in-Charge. Make : Legrand/Anchor /Plaza . |
18 | Supply and fixing in replacement of bush / bearing ofsuitable size in ceiling Fan of following size, complete all as specified and directed by the Engineer-in-Charge. Make : NBC/ SKF. |
19 | Ceiling Fan of 1200 mm sweep |
20 | Ceiling Fan of 1400 mm sweep |
21 | Supply and fixing in replacement of bush / bearing ofsuitable size in Exhaust Fan of following size, complete all as specified and directed by the Engineer-in-Charge. Make : NBC/ SKF. |
22 | Exhaust Fan of 450 mm sweep |
23 | ExhaustFan of 300 mm sweep . |
24 | Exhaust Fan of 230 mm sweep |
25 | Supply and fixing in replacement ofbush / bearing ofsuitable size in Air circulatorsFan of following size, complete all as specified and directed by the Engineer-in-Charge. Make : NBC/ SKF. |
26 | Air circulator Fan of 450 mm sweep |
27 | Air circulators Fan of 600 mm sweep |
28 | Air circulators Fan of 750 mm sweep |
29 | Supply and fixing in replacement of bush / bearing ofsuitable size in wallFan of following size, complete all as specified and directedbythe Engineer-in-Charge. Make : NBC/ SKF. |
30 | Wall mountingFan of 450mm sweep |
31 | Wall mounting Fan of 600mm sweep . |
32 | Supply and fixing in replacement of Metallic clamps for hanging of ceiling Fan with bolts & nuts,,split pin etc., complete all as specified and directedbythe Engineer-in-Charge. |
33 | Supply and fixing in replacement of Stator of Ceiling Fan of following size, complete all as specified and directed bythe Engineer-in-Charge. |
34 | Ceiling Fan of 1200 mm sweep |
35 | Ceiling Fan 1400 mm sweep |
36 | Supply and fixing in replacement ofRotor of ceiling Fan of following capacity, complete all as specified and directed bythe Engineer-in-Charge |
37 | Ceiling Fan of 1200 mm sweep |
38 | Ceiling Fan 1400 mm sweep |
39 | Supply and fixing in replacement ofPVC canopy for ceiling Fan (upper & lower)of following capacity, complete all as specified and directed bythe Engineer-in-Charge. |
40 | Ceiling Fan of 1200 mm sweep |
41 | Ceiling Fan of 1400 mm sweep |
42 | Supply and fixing in replacement of Blade set for ceiling Fanof following capacity with boltsetc., complete all as specified and directed bythe Engineer-in-Charge. |
43 | Ceiling Fan of 1200 mm sweep |
44 | Ceiling Fan of 1400 mm sweep |
45 | Supply and fixing in replacement of cast AluminiumBody cover for ceiling Fanof following capacity with boltsetc., complete all as specified and directed bythe Engineer-in-Charge. |
46 | Ceiling Fan of 1200 mm sweep |
47 | Ceiling Fan of 1400 mm sweep |
48 | Supply and fixing in replacement of rubber reel/pad of suitable size for ceiling Fan of any size and make, complete all as specified and directed bythe Engineer-in-Charge. |
49 | Supply and fixing in replacement ofMS down rodof length 450 mm for ceiling Fan of any size and make, complete all as specified and directed bythe Engineer-in-Charge. |
50 | Spray painting with synthetic enamel paint of(shade as approved by Engineer – in – Charge) after preparation of old surface of ceiling Fan/ exhaust Fan of any make/model/sweep and marking MES No with synthetic enamel paint, complete all as specified directed bythe Engineer-in-Charge. |
51 | Supply and fixing in replacement of Metallic Blade set for ExhaustFanof following sizewith boltsetc., complete all as specified and directed bythe Engineer-in-Charge. |
52 | ExhaustFan of 450 mm sweep . |
53 | ExhaustFan of 300 mm sweep . |
54 | Exhaust Fan of 230 mm sweep |
55 | Supply and fixing in replacement of Metallic louversfor ExhaustFanof following sizewith boltsetc., complete all as specified and directed bythe Engineer-in-Charge. |
56 | ExhaustFan of 450 mm sweep . |
57 | ExhaustFan of 300 mm sweep . |
58 | Exhaust Fan of 230 mm sweep |
59 | Taking down ceiling Fan of any size, any make fixed/hanged at different location in Air Force area, dismantling the Fan and servicing, greasing, oiling and cleaningcomplete and re-assembling the same including replacing split pins flexible copper cable of size 23/0.0076 twin core, 70cm long and refixing the ceiling Fan on the same location in original position, testing and commissioning of Fan for smooth running, as per entire satisfaction of Engineer-in-Charge. Note:- (i)Quoted rate by tenderer of any item of the schedule is inclusive of taking down the ceiling Fan from the position for carrying out servicing repair transportation to work shop & back, changing any component and re-fixing/hanging in position connecting and testing complete. |
60 | All as perserial item No. 22 above but wall mounted Fan of any size and any make. |
61 | All as per serial item No. 22 above but Exhaust Fan of any size and any make |
62 | All as perserial item No. 22 above but Air circulator fan of any size and any make |
63 | Taking down carefully aluminum point wiring (light, fans, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket, etc. and making good disturbed surface of wall/floor, etc. complete all as specified anddirected by Engineer-in-Charge. Note :- Temporary power supply shall be provided by contractor. |
64 | M & L for Point wiring (surface) complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in including non metallic medium grade rigid PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories on the surface of walls/floors/ceilings and making good the disturbed surface, with and including sunken type pressed steel/welded MS terminal box 1.2 mm thick bakelite laminated sheet top cover 3 mm thick and 1.5 Sq mm copper earth continuity wire connected to earth dolly complete for the following , complete all as specified anddirected by Engineer-in-Charge. (a) One light/fan point controlled by one switch . Note : The disturbed surfacesof wall for concealing the wiring shall be make good by applying cement plaster, putty and colour wash etc matching with the existing surfaces.The rate for point wiring shall be deemed to include the cost of making good. |
65 | All as per item No 27 above but one socket outlet 3 pin 5 Amp on same board. |
66 | S & F Switch piano flush button single pole one way 5 amp 240 volts, including connecting and testing , complete all as specified anddirected by Engineer-in-Charge. |
67 | S & F Socket outlet2 in 1 ,3 pin, 5 and 15 amps, flush type, 240 volts, including connecting and testing ,complete all as specified anddirected by Engineer-in-Charge. |
68 | S & F Ceiling rose, surface bakelite, 65 x 50 mm, three terminals, including connecting and testing, complete all as specified anddirected by Engineer-in-Charge. |
69 | Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary on serial page No 17 of tender documents. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail