| 1 | B&R PORTION:-Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground posts embedded in concrete complete all as specified and directed. |
| 2 | Taking down carefully old galvanised stranded steel barbed wire from old RCC posts and removing from site complete all as specified and directed. |
| 3 | Demolition of reinforced concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 4 | Demolition of cement concrete (un reinforced) in ground floors and paving n exc. 15 cm. thickness, below or above ground level complete all as specified and directed. |
| 5 | Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches pillars etc, complete all as specified and directed. |
| 6 | Dismantling mild steel work of any description complete all as specified and directed. |
| 7 | Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 8 | M&L for PCC 1:4:8 type D-2 (40mm graded aggts) as in foundation and mass concretewhere required as per direction of Engineer-in- charge complete all as specified and directed. |
| 9 | M&L for MS work for fencing post and struts made from angle iron and flat iron in any section including cutting tops to shape , drilling holes and notching for fixing of wires etc confirming to Fe -290 or Fe -330, complete all as specified and directed. |
| 10 | S & F galvanised 2 strand, steel barbed wire, 2.20mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, includdigng, securing or tying at crossings with and provisiion of galavnised (Zink coating 60 gsm) mild steel wire, staples or steel pins, etc as directed each line wire to measuredcomplete all as specified and directed. |
| 11 | Supply only chain link MS zink coated 60gm/sqm as per IS 4826 fencing of any mesh size and 3mm dia of wire complete all as specified and directed.NOTE: This item shall be measured and paid as per actual weight or standard weight as per SSR which ever is less. |
| 12 | Fixingonly chain link fencing including line wire, any mesh size and any type of standards rails straining bolt etc including provision of binding wire complete all as specified and directed. |
| 13 | S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 14 | M & L for TMT bars 6mm to 8 mm dia andcut to length bent to shape and binding with MS wire (annealed) not less than 0.9mm Dia complete all as specified and directed. |
| 15 | S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,length of bolt 5 to 10 cmlong and dia of neck not exc 15 mm complete all as specified and directed. |
| 16 | S&F concertina coil made to shape as dia exc 450 mm but n exc 600 mm put on top of wall in betweenY shaped angle iron post and secured with necessary binding wire complete all as specified and directed by Engr in charge. |
| 17 | M&L for brick workwith sub class ‘B’ bricks, straight or curved on plan exc. 6 m mean radius, built in cement mortar 1:6, complete all as specified and directed. |
| 18 | M & L for Walling of random rubble, brought upto course, built in CM 1:6 complete all as specified and directed. |
| 19 | All as per item No. 18 above but except stone complete all as specified and directed. |
| 20 | M&L for boulder filling hand packed tightly (any thickness) at back of walls over arches etc, and raising (or lowering) to the required level compete all as specified and directed. |
| 21 | M&L for rendering 20 mm thick in cement mortar 1: 4 on other than fair faces ofbrick work or stone masonary surfaces, chajja and suspended workfinished even and smooth without using extra cement, complete all as specified and directed. |
| 22 | M&L for rendering 15 mm thick in cement mortar 1: 4 on fair faces ofbrick work or concrete surfaces, chajja and suspended workfinished even and smooth without using extra cement, complete all as specified and directed. |
| 23 | M&L for raking out joint/pointing to random rubble or polygonal rubble stone masonry uncoursed or brought upto courses built in CM complete all as specified and directed. |
| 24 | M& L for raised pointing in cement mortar (1:4) brought upto courses built in CM complete all as specified and directed. |
| 25 | M&L for applying two coats of cement base paint over alkali resistant priming coat on walls including preparation of new plastered or un-plastered surfaces of wall complete all as specified and directed. |
| 26 | M&L for applying one coat of cement base painton walls including preparation of old plastered or un-plastered surfaces of wall complete all as specified and directed. |
| 27 | M&L for applying two coats of cement base paint on walls including preparation of un-plastered surfaces of wall complete all as specified and directed. |
| 28 | S&F framed work such as grills, gratings,steel gate , purlin etc., with ends of bars shouldered and/or riv-eted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanksand similar work conforming to Fe 290 gde E-165 complete all as specified and directed. |
| 29 | M&L for preparation of new untreated surfaces of steel any description over 10 cms width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 30 | M&L for providing precast cement concrete 1:3:6, type C-1 (using 20 mm graded crushed stone agg) as in PCC bonders set in CM 1:6 complete all as specified and directed. |
| 31 | M&L for reinforced cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 32 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelvesincluding supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed. |
| 33 | S&F in repair Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed. |
| 34 | M&L for 100mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in floor/hardstanding and finishing the cement concrete surface complete all as specified and directed. |
| 35 | M&L for 25mm thick PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in sub base and flooring complete all as specified and directed. |
| 36 | M & L for plain cement concrete 1:2:4 type B-2, using 40mm graded crushed stone aggregates as in surfaces channels and drain complete all as specified and directed. |
| 37 | Extra for forming fair finished drain or channel 30 cm inner grith in cement concrete, using extra cement including forms, moulds mitred/stopped ends etc. complete all as specified and directed. |
| 38 | M&L for chequered cement concrete tiles with chemical resistant coating if size 300x300x 25mm thick, set & jointed in neat cement slurryin floors and pointed with grey cement mixed with pigments, laid over and including 20mm thick screed bed in CM 1:6, complete all as specified and directed. |
| 39 | M&L for PCC 1:2:4 Type B1(using 20mm graded agg) in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs,water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 40 | M&L for 75mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base to chequered/interlocking tiles complete all as specified and directed. |
| 41 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 80mm thickness M-40 Grade,laid jointed pointed with grey cement and no pigments,complete all as specified and directed by Engr-in-Charge. Note: The sample shall be got approved by GE before bulk procurement & lot shall be got tested independently by the GE. |
| 42 | M&L for sand filing under floor incl spreading and levelling in layers not exc 25 cm thick complete all as specified and directed. |
| 43 | S&F in repair PVC (SWR) pipes 110 mm dia of bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 44 | E/M PORTION:-Taking down old unsv street light fittings any type from pole/ wall/ other similar situation and refixing, re-connecting the same in existing position after carrying out necessary repair/ replacement of unsv accessories to make the fittings functional, complete all as speecified and directed.Note:-Accessories required to make the fittings functional shall be measured & paid seperately as supply only under relevent items. |
| 45 | Supply only the following accessories to be incorporated for repair of street light fittings taken out under item No-1 above are as under:- |
| 46 | LED driver for street light fittings of 25 to 35 watt capacity complete all as specified and directed. |
| 47 | LED driver for street light fittings of 40/45 watt capacity complete all as specified and directed. |
| 48 | LED driver for street light fittings of 60/70 watt capacity complete all as specified and directed. |
| 49 | LED driver for street light fittings of 90/120 watt capacity complete all as specified and directed. |
| 50 | Glass cover for street light fittings upto 120 watt capacity complete all as specified and directed. |
| 51 | S&F thermo plastic street light weather proof out door type junction box of size 200mmx 160mm x 98mm complete with 4 way connector-01 No, 6 Amps SP MCB-01 No, easily openable and having locking arrangement including incoming and out going cable holes with fixing MS clamp and water tight polymide cable gland for each connection with & including taking down old unsv junction box, complete all as specified and directed. |
| 52 | Excavation in trenches n.exc 1.5M wide and n.exc 1.50M indepth for taking up or laying of under ground cable in soft/loose soil and getting out complete all as specified and as directed. |
| 53 | Returning, filling soil in trenches including spreading levelling, watering and well ramming in layers n.exc 25 cmcomplete all as specified and as directed. |
| 54 | Removal excavated soil not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point all as specified and as directed. |
| 55 | Supply and laying in trenches or passing through pipe 1100 volts grade armoured, heavy duty XLPE electric cable with aluminium conductor of size 25 Sqmm 3.5 core including taking down old/ unsv cable any type complete all as specified and directed. |
| 56 | All as per Item No 50 above but 16 Sqmm 2 core complete all as specified and directed. |
| 57 | All as per Item No 50 above but 10 Sqmm 2 core complete all as specified and directed. |
| 58 | Supply and laying sand river for cushioning with layers of sand 8 cm before laying of cable and 15 cm after laying of cable (total 23 cm) in trenches, duly punning to a thickness of 18 cm complete all as specified & directed. ( Note: Thickness after punning shall be measured for payment ) |
| 59 | Supply and laying burnt best quality locally available bricks laid in trenches perpendicular to UG cable for cable protection complete all as specified and as directed. |
| 60 | S&F in repair 40mm bore galvanised steel water tubing, light grade including all fittingslaid in trenches/ fixed to pole/ along wall/ floor etc for protection of cable/ strip including fixing to pole with M.S. clamp, nuts, bolts etc complete all as specified and as directed. |
| 61 | Supply & fix PVC insulated, 1100 volts grade, stranded aluminium conductor cable 2.5 Sqmm, twin core, connecting from Street light junction box to light fittings including taking down old/ unsv cable any type complete all as specified and directed. |
| 62 | S&F in repair PVC conduit/pipes 15 mm dia and fixed with the pole by clamping / saddling for protection of connecting wires, connection from junction box to light fittings, including taking down old pipe any type complete all as specified and as directed. |
| 63 | S&F in repair decorative post top lantern LED light made up of high grade unbreakable polycarbonate material suitable for & including 20 watt LED lamp (B22) fixed with & including stand post of 40mm dia GI pipe light grade, 1 mtr long and making connection with three core copper flexible cable of suitable size to light fitting complete all as specified and directed. Make:- Havells Cat Part No. LHFXBON1TN5Q014 or Equivalent cat part of make as specified in PS. |
| 64 | Supply and fixing in repair LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make: Havells Cat Part No. ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent Cat part of Make as specified in PS. |
| 65 | Supply and fixing in repair LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make: Havells Cat Part No. ENDURASUNDOWNSL45WLED765PASYBOPC or equivalent Cat part of Make as specified in PS. |
| 66 | Supply and fixing in repair LED flood light 50 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make: HAVELLS Cat Part No. JETAQUANTOPLUSFLP50WLED757SYMLENS or equivalent Cat part of Make as specified in PS. |
| 67 | S&F in repair LT AB cable of size 3x35 sqmm ( for phase) and 1x25 sqmm( for neutral) twisted arround the bar messenger of 1x25 sqmm, made out of aluminium stranded circular compacted conductor, XLPE insulatedall as per IS: 14255, IS 398 part-IV 7098 part-I including suspension clamp with eye hook at every 35 to 40 mtr span mounted on pole by means of MS clamp complete all as specified and directed.Note: MS clamp suitable for pole for holding suspension clamp shall be measured and paid seperately. |
| 68 | S&F street light bracket made out of GI tubing 40mm bore,medium grade, 1.5 metre long bent to shape as directed, including suitable MS clamp of MS Flat with MS bolts, nuts and washer fixed to steel tubular pole/PCC pole duly painted with two coats of aluminium paint including taking down u/s bracket any type all as specified and as directed. |
| 69 | Supply and fixing 1100 Volts grade heavy duty cable PVC insulated aluminum conductor, served with inner sheathing of PVC tape and overall PVC sheathedtwin core cable flat or circular of size of aluminum conductor 6 sq mm stranded conductor including taking down old UNSV cable complete all as specified and directed. |
| 70 | Supply and fixing in repair LED street light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make: Havells Cat Part No.VILUMINASL30WLED757PASYBOPC or equivalent Cat part of Make as specified in PS. |
| 71 | Supply and fixing 1100 Volts grade heavy duty cable PVC insulated aluminum conductor, served with inner sheathing of PVC tape and overall PVC sheathedtwin core cable flat or circular of size of aluminum conductor 10 sq mm stranded conductor including taking down old UNSV cable complete all as specified and directed. |
| 72 | S&F Earthing in replacement for poles and other machinery/eqpt using GI strip as earth lead and MS galvanized steel earth plate electrode 600x600x 6.3mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron strips 32x6mm with GI pipe, nuts, bolts and washers complete upto and PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame, charcoal, common salt15cm at round the earth plate watering pipe 20mm med grade/galvanized and 40mm dia GI pipe light grade for GI strip protected steel with funnel complete all as specified and directed as shown in electrical plate No 3 of SSR Part-I 2009. |
| 73 | S&F in repair of aluminium strip 25 x 3.15mm with saddles and fixing screws, insulators rawal plugs etc forconductor for roof and fixed on wall upto test point complete all as specified and directed. |
| 74 | S&F in repair of copper strip 20 x 3.15mm with saddles and fixing screws, insulators rawal plugs etc forconductor for roof and fixed on wall upto test point complete all as specified and directed. |
| 75 | S&F in repair of galvanized iron strip 32 x 6mm fixed with saddles & fixing screws, PVC dash fastners, insulators fixed from test point to earth on walls or burried in ground / drawn into hume pipe complete all as specified and directed. |
| 76 | S&F in repair of single pointed air termination aluminium rod 12mm dia, 300 mm long complete all as specified and directed. |
| 77 | S&F in repair of test point terminal block made of gun metal or phosphorous bronze 75 x 75 x 25mm of 6mm thickness drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to wall for protection of test point complete all as specified and directed. |
| 78 | Supply and fixing in repair LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.Make: Havells Cat Part No. ENDURAOMNIPLUSSL90WLED757SASYTOPCC or equivalent Cat part of Make as specified in PS. |