Tender For Annual Maintenance Contract (Amc) Of Electrical Distribution System (Internal And External) At Thdcil Complex Rishikesh., rishikesh-Uttarakhand

Tehri Hydro Development Corporation Limited has published Tender For Annual Maintenance Contract (Amc) Of Electrical Distribution System (Internal And External) At Thdcil Complex Rishikesh.. Submission Date for this Tender is 04-05-2023. AMC of Electric Tenders in rishikesh Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

37354284
Tender For Annual Maintenance Contract (Amc) Of Electrical Distribution System (Internal And External) At Thdcil Complex Rishikesh.
Limitted
Indian
Uttarakhand
rishikesh
04-05-2023

Tender Details

Annual Maintenance Contract (Amc) Of Electrical Distribution System (Internal And External) At Thdcil Complex Rishikesh. => Limited

Key Value

Document Fees
INR 2600 /-
EMD
INR 26532.0 /-
Tender Value
INR 26.53 Lakhs /-

BOQ Items

Name of Work: Annual Maintenance contract (AMC) of electrical distribution system (internal & external) at THDCIL Complex Rishikesh.
Sl. No. Item Description
1Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthling the point with1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
2Group A
3Group B
4Group C
5Wiring for twin control light point with 1.5sq.mm FRLS PVC insulated copper conductor singlecore cable in surface/recessed medium class PVC conduit, 2way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
6Wiring for light point/fan point/exhaust fan point/call bell point with1.5sq.mmFRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
7Group A
8Group B
9Group C
10Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor singlecore cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable size MS box and earthing the point with 1.5sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required.
11Wiring for circuit/sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
122 X 1.5 sq. mm + 1X1.5 sq.mm earth wire
132 X 2.5 sq. mm + 1X2.5 sq.mm earth wire
142 X 4sq. mm + 1X4sq. mm earth wire
152 X 6sq. mm + 1X6sq. mm earth wire
164 X 4sq. mm + 2X4sq. mm earth wire
174 X 10 sq. mm + 2X6sq. mm earth wire
18Rewiring for light point/fan point/exhaust fan point/call bell point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.
19Group A
20Group B
21Group C
22Rewiring for twin control light point with 1.5sq.mmFRLS PVC insulated copper conductor single core cable and1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/ PVC conduit including dismantling as required.
23Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
243 x 1.5 sq. mm
253 x 2.5 sq. mm
263 x 4sq. mm
276 x 4sq. mm
286 x 6sq. mm
29Supplying and drawing followingpair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/recessed steel/ PVC conduit as required.
304 Pair
31Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
3220 mm
3325 mm
34Supplying and fixing metal box of following sizes(nominal size)on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
35100 mm X 75mm X 60 mm deep
36180 mm X 100mm X 60 mm deep
37Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc. as required.
385/6 amps switch
392 way 5/6 A switch
4015/16 A switch
413 pin5/6 A socket outlet
426 pin15/16 A socket outlet
43Telephone socket outlet
44Bell push
45Supplying and fixing following modular switch/socketon the existing modular plate & switch box including connections but excluding modular plate etc. as required.
465/6 amps switch
472 way 5/6 A switch
4815/16 A switch
493 pin5/6 A socket outlet
506 pin15/16 A socket outlet
51Telephone socket outlet
52Bell push
53Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
54Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
55Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
563 Module (100mmX75mm)
574 Module (125mmX75mm)
586 Module (200mmX75mm)
598 Module (125mmX125mm)
60Supplying and fixingmetal box of150mm X 75mm X 60mm deep(nominal size) on surface or in recess with suitable size of phenoliclaminated sheet cover in front including providing and fixing 3pin5/6A socket outlet and5/6 A piano type switch, connections, painting etc. as required.
61Supplying and fixing metal box of180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
62Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket out let and 5/6A modular switch, connections etc. as required.
63Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket out let and 15/16 A modular switch, connections etc. as required.
64Supplying and fixing 3 pin,5 A ceiling rose on the existingjunction box/wooden block including connections etc. as required.
65Supplying and fixing brass batten/angle holder including connectionetc. as required.
66Installation,testingandcommissioning of ceiling fan, including wiring the down rods of standard length (upto30 cm) with 1.5sq. mmFRLS PVC insulated,copper conductor, single core cable, including providing and fixingphenoliclaminated sheet cover on the fan box etc. as required.
67Installation of exhaust fan in the existing opening, including makinggood the damage, connection, testing, commissioning etc. as required.
68Up to 450 mm sweep
69510 mm sweep
70Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board,240V,on surface/recess ,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
718 way , Double door
72Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415V,on surface /recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections,powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
734 way (4 +12), Double door
746 way (4 +18), Double door
75Supplying and fixing of following ways surface/recess mounting, vertical type,415V,TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phaseOutlets are required.)
764 way (4 +12), Double door
778 way (4 +24), Double door
78Supplying and fixing 5A to 32A rating, 240/415V, 10kA,"C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.
79Single pole
80Double pole
81Triple pole
82Supplying and fixing following rating, double pole, 240V, isolator in the existing MCBDB complete with connections, testing and commissioning etc. as required.
8340 A
8463 A
85Supplying and fixing following rating, four pole, 415V, isolator in the existing MCBDB complete with connections, testing and commissioning etc. as required.
8640 A
8763 A
88100 A
89Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/recess, complete with testing and commissioning etc. as required.
90For 6 way, Double door TPNMCBDB
91Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7meter long etc. with charcoal/ coke and salt as required.
92Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
93Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
94Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
95Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 kV grade o following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
96Up to 35 sq. mm
97Laying and fixing of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 kV grade of following size on wall surface as required.
98Up to 35 sq. mm (clamped with1mm thick saddle)
99Supplying and makingcable route marker with cement concrete 1:2:4 (1 cement: 2 coarsesand: 4 graded stone aggregate 20 mm nominal size )of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10 cm including inscription duly engraved as required.
100Laying of one number PVC insulated and PVC sheathed /XLPE power cable of11KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
101Upto120 sq. mm
102Above 120 sq. mm&upto400 sq.mm
103Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meterlead as per direction of Engineer-in-charge :
104Water bound macadam road
105bituminous road
106Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level : Position cement, concrete1:2:4 (1cement: 2 coarse and (zone-III) : 4 graded stone aggregate 20 mm nominal size)
107Erection of metallic pole of following length in cement concrete 1:3:6 (1cement : 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
108Above 4.5 meter and up to 6.5meter
109Above 6.5 meter and up to 8.0 meter
110Above 8.0 meter and up to 10.0 meter
111Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.
112Erection of stay set complete (galvanized) in cement concrete 1:3:6 ( 1 cement: 3 coarse and : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
113Dismantling of over head lines comprising of copper/aluminum over head conductor, G.I. wire, cross arms, insulators etc. as required.
114Dismantling of pole/street light standard/ strut embedded in cement concrete foundation etc. as required.
115Supply andlaying of aluminum conductor PVC insulated armored served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-In charge , complete in all respect. The armoring of the cable shall be properly connected with the earth conductor by clamps etc.
1164 sq. mm 4core
1176 sq. mm 4core
11810 sq. mm 4core
11916 sq. mm 4core
12025 sq. mm 3-1/2core
12135 sq. mm 3-1/2core
12250 sq. mm 3-1/2core
12370 sq. mm 3-1/2core
124Painting of the electric pole with2coatsof aluminum paint over red oxide primer complete in all respect.
125Supply and fixing of call bell of approved make on polished MDFEG/ Teak ply board including making connections etc. complete in allrespect.
126Supply and fixing of electronic fan regulator120-280V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work.
127Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT-AAA
128Supply and fixing of LED Street light Fitting having die cast Aluminum body and diffuser with driver set suitable for 52 watt to 72 Watt. Confirming to IP66 Protection complete in all respect. CAT-AA
129Supply and fixing of decorative8 to 16 Watt LED bollard luminaries with driver set confirming to IP 65 protection complete in all respect. CAT- AA
130Supply and fixing of decorative 40 to 45Watt LED Post top in direct light luminaries having Pressure die cast aluminum body and Clear glass with driver set confirming to IP 65 and above protection complete in all respect. CAT-AA
131Copper winding work of ceiling fan/exhaust fan/ pedestal fan/ wall fan including old burnt cu. Wire adjusted complete in all respects.
132Supply & fixing of fan condenser 2.5 mfdcomplete in all respects.
133Supply & fixing of fan bearing 6201/6202 complete in all respects.
134Supply & fixing of ceiling fan bush complete in all respects.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail