}

Tender For Creation Of Green Urban Infrastructure By Developing Bollywood Park At Welcome Jheel Near Welcome Metro Station In Shahdara North Zone Under Waste To Art, Delhi-Delhi

Municipal Corporation Of Delhi has published Tender For Creation Of Green Urban Infrastructure By Developing Bollywood Park At Welcome Jheel Near Welcome Metro Station In Shahdara North Zone Under Waste To Art. Submission Date for this Tender is 11-05-2023. Infrastructure Work Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

37350099
Tender For Creation Of Green Urban Infrastructure By Developing Bollywood Park At Welcome Jheel Near Welcome Metro Station In Shahdara North Zone Under Waste To Art
Open Tender
Indian
Delhi
Delhi
11-05-2023

Tender Details

Creation Of Green Urban Infrastructure By Developing Bollywood Park At Welcome Jheel Near Welcome Metro Station In Shahdara North Zone Under Waste To Art

Key Value

Document Fees
INR 2360 /-
EMD
INR 3725000.0 /-
Tender Value
INR 27.25 Crore /-

BOQ Items

Name of Work: Creation of green urban infrastructure by developing “Bollywood Park” at Welcome Jheel near Welcome Metro Station in Shahdara North Zone under “Waste to Art”
Sl. No. Item Description
1Creation of green urban infrastructure by developing “Bollywood Park” at Welcome Jheel near Welcome Metro Station in Shahdara North Zone under “Waste to Art”
2GRAND ENTRY MOUNT RUSHMORE –he structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites of MCD. Minimum Height – 20 feet. Minimum Width – 20 feet. Minimum Length – 40 feet. Foundation Minimum Width – 24 feet | Minimum Length – 44 feet. Foundation Specs – Brickwork all around the platform as a base for the platform on which installation shall be placed 4 inches of PCC below the concrete slab RCC M - 25 with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication, Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge
3GRAND ENTRY BOLLYWOOD TOPOGRAPHY –The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites of MCD. Minimum Height – 7 feet. Minimum Width – 6 feet. Minimum Length – 60 feet . Foundation Minimum Width – 8 feet. Minimum Length – 62 feet. Foundation Specs – Brickwork all around the platform as a base for the platform on which installation shall be placed4 inches of PCC below the concrete slab RCC M - 25 with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication, Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge
4MOVIE SETS CATEGORY 1 – The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites of MCD. Minimum Height – 16 feet. Minimum Width – 40 feet. Minimum Length – 40 feet. Foundation Minimum Width – 42 feet | Minimum Length – 42 feet.Foundation Specs – Brickwork all around the platform as a base for the platform on which installation shall be placed4 inches of PCC below the concrete slab RCC M - 25 with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication, Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge
5MOVIE SETS CATEGORY 2 -The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites of MCD. Minimum Height – 20 feet. Minimum Width – 40 feet.Minimum Length – 50 feet. Foundation Minimum Width – 42 feet. Minimum Length – 52 feet.Foundation Specs – Brickwork all around the platform as a base for the platform on which installation shall be placed 4 inches of PCC below the concrete slab RCC M - 25 with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication, Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge
6MOVIE SETS CATEGORY 3- The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites of MCD. Minimum Height – 20 feet. Minimum Width – 40 feet. Minimum Length – 70 feet. Foundation Minimum Width – 42 feet. Minimum Length – 72 feet for supporting against the wall.Foundation Specs – Brickwork all around the platform as a base for the platform on which installation shall be placed4 inches of PCC below the concrete slab RCC M - 25 with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication, Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge
7MOVIE SCENES CATEGORY 1-The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites of MCD. Minimum Height – 8 feet. Minimum Width – 6 feet Minimum Length – 20 feet. Foundation Minimum Width – 8 feet | Minimum Length – 24 feet. Foundation Specs – Brickwork all around the platform as a base for the platform on which installation shall be placed 4 inches of PCC below the concrete slab RCC M - 25 with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication, Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge
8MOVIE SCENES CATEGORY 2- The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites of MCD. Minimum Height – 7 feet. Minimum Width – 5 feet. Minimum Length – 15 feet. Foundation Minimum Width – 7 feet Minimum Length – 17 feetFoundation Specs – Brickwork all around the platform as a base for the platform on which installation shall be placed4 inches of PCC below the concrete slab RCC M - 25 with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication, Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge.
9MURALS CATEGORY 1 – The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites of MCD. Minimum Height – 8 feet. Minimum Width – 2 feet. Minimum Length – 12 feet. Foundation Minimum Width – 4 feet Minimum Length – 14 feet.Foundation Specs – Brickwork all around the platform as a base for the platform on which installation shall be placed4 inches of PCC below the concrete slab RCC M - 25 with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication, Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge
10MURALS CATEGORY 2 – The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites of MCD. Minimum Height – 10 feet. Minimum Width – 2 feet. Minimum Length – 15 feet. Foundation Minimum Width – 4 feet Minimum Length – 17 feet Foundation Specs – Brickwork all around the platform as a base for the platform on which installation shall be placed4 inches of PCC below the concrete slab RCC M - 25 with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication, Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge
11FIGURES CATEGORY 1 –The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites of MCD. Minimum Height – 7 feet. Minimum Width – 3 feet. Minimum Length – 14 feet. Foundation Minimum Width – 5 feet | Minimum Length – 6 feet Foundation Specs – Brickwork all around the platform as a base for the platform on which installation shall be placed4 inches of PCC below the concrete slab RCC M - 25 with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication, Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge
12FIGURES CATEGORY 2 –The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites of MCD. Minimum Height – 5 feet. Minimum Width – 4 feet. Minimum Length – 5 feet. Foundation Minimum Width – 6 feet Minimum Length – 7 feet.Foundation Specs – Brickwork all around the platform as a base for the platform on which installation shall be placed4 inches of PCC below the concrete slab RCC M - 25 with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication, Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge
13FILLERS CATEGORY 1 –The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites of MCD. Minimum Height – 10 feet. Minimum Width – 4 feet. Minimum Length – 5 feet. Foundation Minimum Width – 6 feet Minimum Length – 7 feet. Foundation Specs – Brickwork all around the platform as a base for the platform on which installation shall be placed4 inches of PCC below the concrete slab RCC M - 25 with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication, Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge.
14FILLERS CATEGORY 2 – The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites of MCD. Minimum Height – 8 feet. Minimum Width – 5 feet. Minimum Length – 5 feet. Foundation Minimum Width – 7 feet. Minimum Length – 7 feet Foundation Specs – Brickwork all around the platform as a base for the platform on which installation shall be placed4 inches of PCC below the concrete slab RCC M - 25 with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication, Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge
15GRAND EXIT RED CARPET 1–The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites of MCD. Minimum Height – 12 feet. Minimum Width – 12 feet. Minimum Length – 50 feet. Foundation Minimum Width – 14 feet | Minimum Length – 52 feet. Foundation Specs – Brickwork all around the platform as a base for the platform on which installation shall be placed4 inches of PCC below the concrete slab RCC M - 25 with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication, Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge.
16GRAND EXIT AWARD FUNCTION–The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites of MCD. Minimum Height – 12 feet. Minimum Width – 10 feet. Minimum Length – 15 feet. Foundation Minimum Width – 12 feet Minimum Length – 17 feet for supporting against the wall. Foundation Specs – Brickwork all around the platform as a base for the platform on which installation shall be placed 4 inches of PCC below the concrete slab RCC M - 25 with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication, Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge.
17GRAND EXIT PHOTO BOOTH–The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites of MCD. Minimum Height – 8 feet. Minimum Width – 2 feet. Minimum Length – 4 feet. Foundation Minimum Width – 4 feet. Minimum Length – 6 feet for supporting against the wall. Foundation Specs – Brickwork all around the platform as a base for the platform on which installation shall be placed4 inches of PCC below the concrete slab RCC M - 25 with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication, Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be emboded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge
18Horticulture Supply & Plantation of Ficus benjamina (green) height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bag
19Supply & Plantation of Ficus nuda height 120-135 cm. with 6-8 branches and lush green foliage in gunny bag size 25 cm as per work-in- charge
20Supply & Plantation of Ficus panda of height 45-60 cm. with 6-7 branches and healthy foliage in polybag of size 25 cm as per diraction of officer-in-charge
21Supply & Plantationof Rhapis Palm having ht. 45 cm to 60 cm with 5 to 7 suckers, well developed,full of fresh andhealthy leaves in 25 cm size of Earthen pot / Plastic pot. as per direction of the officer-in-charge
22Supply & Plantationof Areca Palm having ht. 1.80 m to 2.10 m with 8 to 10 suckers, well developed, fresh and healthy with lush green foliage in HDPE bag as per direction of the officer-in-charge
23Supply & Plantationof Wadelia trilobata,full of leaves in 15 cm size in plastic Bag as per direction of the officer-in-charge
24Supply & Plantationof Syngonium (Butterfly) variegated with 2-3 suckers healthy foliage in Earthen Pot/ Plastic Pot of size 20 cmas per direction of the officer-in-charge
25Supply & Plantationof Iresine herbstii, of height 25-30 cm., full of branches well developed in 15 cm size of Earthen Pot / Plastic Pot. As per direction of officer-in-charge
26Supply & Plantationof Tabernaemontana coronaria (Chandni single) variegated of height 105-120 cm., multibranched, bushy in big size HDPE bag as per direction of the officer-in-charge
27Supply & Plantationof Tecoma gaudichaudi of height 90-105 cm.,bushyin big size HDPE bag as per direction of the officer-in-charge.
28Providing and laying of Selection no. 1 grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge
29Providing and Fixing Furcaria Variegated hybrid well developed with fresh & healthy foliage 20 and above attractive leaves in 35 cm Cement Pot as per direction of the officer-in-charge.
30Providing and Displaying Topiary of Ficus Panda well developed with fresh & healthy foliage with 3 to 4 Ball and 60 to 75 cm spread each Ball, 135 to150 cm ht., in 35 cm HDPE bags /Cement Pot as per direction of the officer-in-charge.
31Providing and Displaying Topiary of Ficus Nuda well developed with fresh & healthy foliage from Top to Bottom with single piller 75 to 90 cm spread,195 to 210 cm ht. in 35 cm HDPE Bag/Cement Tray /Cement Pot as per direction of the officer-in-charge.
32Providing and Displaying Topiary of Casuarina fresh & healthy having 5 to 6 specific shape and size ball well developed 195 to 210 cm ht. in 40 cm HDPE Bags /Cement Pot as per direction of the officer-in-charge.
33Providing and Displaying Cyprus Golden Conical Shape 150 to 165 cm ht., with fresh and healthy Golden colour foliage in 35cm Cement Pot as per direction of the officer-in-charge.
34Providing and Displaying Ficus resnold Topairy well developed with fresh & healthy 6 to 7 big ball specific size 210 to 240 cm ht in 45 cm Cement Pot as per direction of the officer-incharge.
35Providing and fixing of Ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.
36Providing and fixing of Mussaenda erythrophylla (Rosea) of height 60-75 cm. multi branched in earthen pot of size 25 cm
37Providing and fixing of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.
38Providing and fixing of Pterospermum acerifolium (Kanak Champa) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
39Providing and fixing of Cassia biflora of height 90-105 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge.
40Providing and fixingof Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. Well developed with fresh & healthy bushy plant in full bloom 75 to 90 cm ht. plant in 40 cm Cement Pot
41Providing and fixingof Cycus revoluta in 35 cm challi, specimen plant, having 30 to 40 with fresh and healthy, leaves having 25cm to 30cm circumfrance of base stem well developed
42Providing and fixing of Largerstroemia indica diffrent color of height 90-105 cm. multibranched in poly bags of size 25 cm as per direction of the officer-in-charge.
43Providing and fixing of Bauhinia blakeana (Kachnar) diffrent color height 120-150 cm. in big poly bag size 25 cm
44Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge.
45Providing and fixing of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge.
46Providing and fixing of Agave Plant well developed size 1.5 ht. And 8 to 11 leaves in HDPE bagas per direction of the officer-in-charge
47Prividing and fixing of Yucca plant for the Ht. 2.5" to 3" in HDPE bags
48Providing and Fixing Bottle palm ht. 270-300 cm bottom girth 40-50 cm well developed in big HDPE bag
49Providing and Fixing Washingtonia filifea palm stem ht. 120-135 cm with 8-10 healthy leaves lush green leaves well developed in big size HDPE Bag
50Providing and Fixingof Juniperus prostrata with 10 to 12 latral branches ht. 3.5" to 4" and green foliage in HDPE Bags as per direction of the officer-in-charge.
51Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Holes 60 cm dia, and 60 cm deep
52Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Holes 45 cm dia, and 45 cm deep
53Artifical Vertical Garden Steel work in built up tubular (round, squarerecetangular hallow tubes etc.) trusses etc. including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted with specialshaped washers etc. complete. Hot finished welded type tubes as per direction of officer in charge.
54Supply & Installation of UV protected Artificial VerticalGarden of size 1mtr X1mtr, which is having Mix bushes, fems and bunches of different type of plants and flowers to give it a dense forest look. Thisis to be tiedup with the help of steel wire on a MS netted frame. Vertical Garden Look and Design as per direction of officer in charge.
55Supply & Installation of Artifical Vedrtical Garden of size ie.e 40cm X 60cm which is having artifical jade plant leaves and give it a look of jade hedge. This is to be tie-up with the help of steel wire on a MS netted frame . Vertical Garden Look and Design as per direction of officer in-charge.
56Artificial grass Brick Aggregate for Flooring Providing and laying 75mm thick compacted bed of dry brick aggregate of 40mm thick nominal size including spreading, well ramming, consolidating and grouting with Jamuna sand including finishing smooth etc. complete as per direction of work in charge.
57Providing and laying of artificial turf grass having piles of 35 mm height with following specifications:Density: 18900 stitches/sqm ± 3%,DTEX: 6700, PE (C-Shape) + PP curl,Backing: PP cloth + Mesh + Black SBR latex
58CC for flooring Provision and laying in position cement concrete of specified grade excluding and cost of centering and shuttering. Allwork upto plinth level in CC 1:3:6 (1 Cement: 3Coarse Sand: 6 graded stone aggregate 20 mm nominal size)
59Artistic wall painting Educational Wall Painting: applying waterproof creative inspirational wall art with maintenance of walls using POP for children park Painting material should be reputed brand such as Asian paints, Indigo paints, Burger, Nerolac etc. as per direction of Officer In charge.
60Sitting arrangement Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lifts upto 1.5 m including getting out the excavated soil and disposal of surface excavated soil as directed within a lead of 50 m .All kinds of soil.(i) For Foundation : 4x 0.6x0.6x0.6 =0.86 m3 (ii) For Side Wall : 4x2.4x0.25x 0.12=0.28 m3 Total Excavation: 0.86+ 0.28= 1.14 m3
61Provision and laying in position cement concrete of specified grade excluding and cost of centering and shuttering. Allwork upto plinth level (a)    1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size
62Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth (a)    Cement mortar 1:6 (1 cement: 6 coarse sand)
63Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
64Art work on sitting arrangement/benches by making architectural designs, moulding, shapes ( like trunk of tree, bamboos, wooden phalli design, any element representing culture or tradition and applying proper texture and painting coats to suit a particular aesthetic elements).
65Aercon Cement PanelThicknees 50mm, nominal weight 42kg, per sqm., apparent density 840 kg per cub meter, axial compression load per meter width 75 KN/M, Bending (4.point Uniformely distuributed load 2.9 m span 55 kg per cub meter, flexuralstrength modules of rupture 50 kg per cub cm thermal conductivity 0.18, sound transmission coefficient 38 db., fire rating 105 minutes, surface spread of length class one, fire propagation index three, class P ignitbility as per direction of officer in charge.
66Container Based Office Block : Supply, designing, fabrication and installation of Office block using container of size (LxBxH) 20’0”x8’0” X 8’6”Structure shall bemade in MS pipes of size 50 X 25 X 2mm (at 04 walls and false ceiling of the container) with provision of nut-bolts / fastners. The flooring shall be made using ceramic tiles of reputed brand having size 1" X 1". Walls shall be made using MDF Board leak proof/water proof of 6mm thickness and having adequate provision for thermal insulation, door Wardrobe, PVC office curtain & 2 window for air ventilation. Door shall be made using GI Sheet on the outside and MDF Board on the inside having size 7"x3". Addition to this, 1 PVC doors shall be provided in the Toilet of size 8"x5". Toilet shall have 1 Nos Toilet pots (EWC) with all sanitary and CP fittings with tap, towel ring, paper holder including all plumbing works with GI/PVC in each unit and good quality mirror. The office block shall also have necessary arrangements of lighting such as Lights,6 Nos. 6 watt conceal spot light, 2 Nos. 15 watt LED Tube Lights, 4 Power sockets 16 Amp., AC Power Socket 32 Amp., 1 Nos. , 3 Nos. Exhaust fans, 2 nos. small cealing fan and 2 Nos. water proof bulkhead wall spot light for outside. The container(s) should be placed in the balanced manner & should be properly grouted in the ground. All the metal parts shall be duly painted using good quality of paint.(As per direction of the officer-in charge)
67Container Based Store Room: Supply, designing, fabrication and installation of store room using container of size (LxBxH) 20’0”x8’0” X 8’6”Structure shall bemade in MS pipes of size 50 X 25 X 2mm with provision of nut-bolts / fastners. The flooring shall be made using ceramic tiles of reputed brand having size 1" X 1". Walls shall be made using MDF Board of 6mm thickness. Door shall be made using GI Sheet on the outside and MDF Board on the inside having size 7"x3".The Store room shall also have necessary arrangements of Window and lighting such as Lights,2 Nos. 6 watt conceal spot light, 2 Nos. 15 watt LED Tube Lights, 2 Power sockets 16 Amp., 1 Nos. Exhaust fans and 2 Nos. water proof bulkhead wall spot light for outside. The container(s) should be placed in the balanced manner & should be properly grouted in the ground. All the metal parts shall be duly painted using good quality of paint.(As per direction of the officer-in charge)
68Container Based Guard Room: Supply, designing, fabrication and installation of guard room using container of size (LxBxH) 20’0”x8’0” X 8’6”Structure shall bemade in MS pipes of size 50 X 25 X 2mm with provision of nut-bolts / fastners. The flooring shall be made using ceramic tiles of reputed brand having size 1" X 1". Walls shall be made using MDF Board of 6mm thickness. Door shall be made using GI Sheet on the outside and MDF Board on the inside having size 7"x3".The Store room shall also have necessary arrangements of Window and lighting such as Lights,2 Nos. 6 watt conceal spot light, 2 Nos. 15 watt LED Tube Lights, 2 Power sockets 16 Amp., 1 Nos. Exhaust fans and 2 Nos. water proof bulkhead wall spot light for outside. The container(s) should be placed in the balanced manner & should be properly grouted in the ground. All the metal parts shall be duly painted using good quality of paint.(As per direction of the officer-in charge)
69TOILETS Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.2.6.1 All kinds of soil
70Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 2.10.1 All kinds of soilPipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
71Providing and laying in position cement concrete of specified grade excluding the cost of centering andhuttering - All work up to plinth level1:5:10 (1 cement : 5 oarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size)
72Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
73Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
7412 mm cement plaster of mix :1:4 (1 cement: 4 fine sand)
75Neat cement punning.
76Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) cum
77Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
78Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Cold twisted bars
79Providing and fixing in position precast R.C.C. manhole cover and frame.Circular shape 560 mm internal dia
80Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand)cluding 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : 19.27.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
81Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making SUB HEAD : 19.0 DRAINAGE 364 Code Description Unit Rate No. channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 19.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg(weight of cover 23 kg and weight of frame 15 kg) : 19.7.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
82P/L NP2 class R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of (1:2):250 mm dia. R.C.C. pipe
83Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
84Providing & Fixing of Container of size (20"x10"x8"-6" feet) Base Frame 125x60mm/C channel Cross frame 75x40m SQARE Pipe Four Locks the container attached with loading & unloading Purpose Corner post piller 100x100 mm, Floor Water proof ply cement fiber board with 19 mm th. Fitted with screw on pipe, PVC Vinyl flooring thickness 1.2 mm. Wall & roof 1.2 mm M.S. Sheet and (18 Gauge), One main entry door of size 3" x 7" made with iron made, Panel of container with locking provision. One window A/C provision. Electrical and lights: Two LED tube lights, switch socket & power points for plugging as per required, two extr pints & other electrical equipment, 16 A A/C point-2 nos. one main MCB, One bulkhead light out side the container & male female outside the container All branded eletrical Wiring and Two Cabin Fan.Full of glass wool thickness 50 mm insulationn to reduce heat & sound. Wall panelling with MDF Plywood Thickness - 6mm (Approx). Full of Blue paint outside the container.
85Ceramic Glazed Tiles 1st quality 300 x 300 mm in all shades and designs of White, Ivory, grey, Fume Red brown etc.
86Supply and installation of 20 PVC door in Toilets blocks of size (6"x3")
87Supply and installation of urinals with all plumbing works in GI/PVC in the container
88Supply and installation ofToilets pots (EWC) with all sanitary and CP fittings with tap, towel ring, paper holder including all plumbing works with GI/PVC in the Cabin
89Transportation Charges For Loading and unloding of Container
90Artistic Painting & Graffiti of Containers - 20ftx8ft. Theme based artistic painting of containers for beautification of containers using high grade external metal PU paint.
91Arrtistic Gate Entry Gate - The structure needs to be made with a minimum area as per below details, using the scrap/waste material available at the sites of MCD. Minimum Height – 15 feet, Minimum Width – 05 feet, Minimum Length – 25 feet, Designing Fabrication , Installation to be made with scrap waste material . For finishing while installation of miniature / sculpture / Applying Primer coats two or mare coats of approved quality primer painting with P.U coating automotive paint of approved quality with giving proper finish as per direction of work in-charge
92MS Gate Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.2.6.1 All kinds of soil
93Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size)
94Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg
95Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing andreinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
96Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
97Providing & fixing of White River (Stone) Pables size of 2" to 2.50" dia in natural colour at site of work including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge.
98Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
99Providing and Fixing of S.S. Sign Bords of ( Grade 304) 0.45m x 0.91m Size with 2 Supports of length- 0.91m S.S Pape fixing of Retro reflective sign boards made of 4 mm thick aluminum sheet ,face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type –IV of ASTM-D 4956-01 In green and silver white including subject matter, message(bilingual) ,symbol and borders etc as per IRC:67-2001 , pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 And fixing the same with suitable sized aluminum alloy rivets Cost including making holes in pipe providing and fixing massage plate of requires size Fixing of base frame of board with Earth work in excavation of (0.2x0.2x0.5), PCC of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.2 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) of size 20x.20x.1 , C.C specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.2 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-incharge.
100Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required, in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
101Providing and fixing of Metro Sheet Pre painted galvanized HI-Rib Roofing/Cladding system comprising of profit sheeting having 1060mm cover width, length 3657.6 (12 foot) thickness 0.50mm. The sheet shall have minimum two/three small stiffing ribs in between pans, zinc coating mass total of (both side) as per IS:277, with coating of regualr modified polyester paint (RMP) system as per IS:12246. The color coating shall comprise of 15-20 micron finish coat over 5-7 micron primer coat on the exposed side and 5-7 micron over 5 micron primer on back side.
102Garden Hut Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lifts upto 1.5 m including getting out the excavated soil and disposal of surface excavated soil as directed within a lead of 50 m .All kinds of soil. (i) For Foundation : 4x 0.6x0.6x0.6 =0.86 m3 (ii) For Side Wall : 4x2.4x0.25x 0.12=0.28 m3 Total Excavation: 0.86+ 0.28= 1.14 m3
103Supply of6 nos m.s pipe of 150mm od and 10ft heightfor column
104welding of ms plate of 6 mm thickness to one end of 150 mm pipe
105Providing and laying 75mm thick compacted bed of dry brick aggregate of 40mm thick nominal size including spreading,well ramming,consolidating and grouting with jamuna sand including finishing smooth etc. complete as per direction of Engineer –in charge.
106Provision and laying in position cement concrete of specified grade excluding and cost of centering and shuttering. Allwork upto plinth level (a)    1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size
107(b)  1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
108Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth(a)    Cement mortar 1:6 (1 cement: 6 coarse sand)
109Steel work in built up tubular(hot finished welded type round,square,rectangular hollow tubes etc.) trusses, seating arrangement etc including cutting,hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washersetc. Complete
110Providing and fixing of roofing sheet in paper cement of 8mm thickness and 8’x4’.
111Providing & fixing of gi mesh, laying cc of 60mm thickness ,waterfroofing,& Art work on Slablike kavelu design/ wooden phalli/ grass/ bamboo etc. Also art work onmoulding and/ or arches by givingshape to suit a particular aesthetic elements (like trunk of a tree, Bamboos, birds, animal, characters /any element representing culture or tradition) and applying proper texture and painting coats
112Art work over columns of 8’ height including architectural design, mouldings, arches, shapes (like trunk of a tree, bamboos, rock or any character or element representing culture or tradition) and applying proper texture and paint to the finished surface to enhance the aesthetics.
113Providing Sculpture like Man / Woman, Animal, Musical instrument or any character or element representing culture or tradition made in RCC / GRC
114Art work over Seats / Benches including architectural design, mouldings, arches, shapes (like trunk of a tree, bamboos, rock or any character or element representing culture or tradition) and applying proper texture and paint to the finished surface to enhance the aesthetics.
115Art work over floor/wall by making design/texture and applying paint to the finished surface to enhance the aesthetics.
116Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
117Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe
118Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
119Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All kinds of soil.
120"Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge."
121"Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge)."
122Supplying and stacking at site. Good Earth
123Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
124Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-incharge
125"""Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern."""
126Providing & Laying of 100x100x60mm. Thick cement concrete paver (Red & Dark Grey) of Grade M-35 under green technology standard as epr IS 15658:206. Manufactured by PLC based automated block/paver making machine having compression and vibration both in sequence using multi cavity precision steel mould and automated curing chamber with waterless curing. The mixing of concrete must be done usig a batching plant with proper measured quantities of raw material including cement and mixed in automatic planetary mixer to give uniform mixing and quality of conrete as per design mix. Manufacture i two layers First the bottom layer must be filled. Top layer should be as per BIS standard. The finished paver requires a rough finish on the top surface & over a layer of coarse sand 30mm thick spreading of fine sand to fill up joints after of paver and compacted with plate vibrator etc. including all Taxes Complete as per direction of officer-in-charge.
127Providing & Laying of Designer concrete paver in color Random Size Like (78mm x158mm x80mm), (158mm x 158mmx80mm) and (238mm x158mm x80mm). Thick cement concrete paver of Grade M-35 under green technology Standard as per IS 15658:2006. Manufactured by PLC based automated block/paver making machine having compression and vibration both in sequence using multy cavity precious steel mould and automated curing chamber with waterless curing. The mixing of concrete must be done using a batching plant with proper measured quatities of raw material including cement and mixed in automatic plantary mixer to give uniform mixing and quality of concrete as per design mis. Manufacture in two layers First the bottom alyer must be filled. Top layer sould be as per BIS standard. The finisehed paver requires a rough finish on the top surface & over a layer of coarse sand 30mm thick spreading of fine sand to fill up joints after of paver and compacted with plate vibrator rtc. Including all taxes comlete as per direction of Engineer-in-Charge.
12815 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand)
129Neat cement punning.
130Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size)
131"Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)"
132Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
133"Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform"
134"Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more"
135Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
136Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm nominal inner dia Pipes
137Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm nominal outer dia Pipes
138Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
139Solar Power Supply,Installation,Testing and Commissioning of ongrid Solar Photovoltaic PowerPlant conforming to MNRE specifications as amended, consisting of Mono/PolyCrystalline silicon solar cells,net metering facility,necessary protections,earthing,mounted onExisting structure of suitable strength with following components complete as required:-a)Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286/IEC61215,IS/IEC61730-Part-1,IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall notbe less than 16.5%. PVmodules used in solar powerplants/systems must be warranted for the output peak watt capacity, which should not beless than 90%at the end of 10years and 80% at the end of 25 years. b)Power Conditioning Unit (PCU)of350-800 VDC Input voltage range and 400VAC, three phase, 4wire,50Hz+/-2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%,total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50degree C.The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories. d)Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable alongwith glands,lugs and other accessories etc. as required. e) Lightning and surge voltage protection.f)Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1kV grade armoured power and control cables between solar modules, mainpower cable to grid supply PCU unit alongwith supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
140Design, manufacture and supply of5 KWSolar Power Tree Grid Connected System with net metering facility.a)Solar Photovoltaic Module of capacity 265Wp or above, manufactured in India,conforming to IS14286/IEC61215,IS/IEC61730-Part-1,IS/IEC61730-Part-2.SolarPhotovoltaic Module conversion efficiency shall not be less than16.5%.PVmodules used in solar powerplants/systems must be warranted for their output peak watt capacity,which should not be less than90%at the end of 10years and 80%at the end of 25 years. b)Power Conditioning Unit(PCU)of350-800VDC Input voltage range and 400VAC,three phase,4wire,50Hz+/-2.5Hz,output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50degreeC.ThePCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories.d)Fixing of Array junction box & Main junction box with IP65protection and termination arrangement for incoming and outgoing cable alongwith glands,lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f)Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit alongwith supplying & fixing of necessary channel/conduit lugs and other accessories etc.as required.
141Providing and laying in position M25 grade reinforced cement concrete foundation of size 600 mm(L) x 600 mm wide and 1200 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -1160mm long (approx.) - 8 nos.and reinforcement of cold twisted bar of 8 mm dia - 1600 mm (approx.) - 8 nos. (with 150 mm spacing) as required with supplying andpositioning of 4 nosfoundation bolts of size 20 mm dia,750mm long,j type i/c 2 nos. ,template anchor plate of size 225mmx225mmx3mmand providing DWC HDPE pipe for cable entry & exit as required for 7 m and 8 mtr pole
142Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
143Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
144Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
145CCTV Surveillance system S/I/T/C of 2MP varifocal lens Bullet IP Camera with following specifications:- Image Sensor: 1/2.8 2MP CMOS or better** Minimum Illumination: 0.1 lux color, 0 lux with IR or better ** Shutter Speed:1/3 – 1/100,000 s Frame Rate:25 fps or better ** Lens: 2.8 to 12mm Varifocal lens Video Compression: H.265 or better ** S/N Ratio: >45dB Resolution: (1920x1080) or better ** Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1X IR Range: Minimum 20m Operating Temperature: -20 to 55 deg Cent Weatherproof Standard:IP66 or better ** Safety standard: UL
146S/I/T/C of 2MPPTZCamera with following specifications:- Image Sensor: 1/2.8 2MP CMOS or better** Minimum Illumination: 0.1 lux color, 0 lux with IR or better ** Shutter Speed:1/3 – 1/100,000 s Frame Rate:25 fps or better ** Lens: 30 X ZOOM Video Compression: H.265 or better ** S/N Ratio: >45dB Resolution: (1920x1080) or better ** Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1X IR Range: Minimum 20m Operating Temperature: -20 to 55 deg Cent Weatherproof Standard:IP66 or better ** Safety standard: UL
147S/I/T/C of 32 channel NVR with the following specifications: Camera resolution:upto8MP Interface: 1 HDMI, 1VGA minimum Compression :H.265or better** Network Throughput :160Mbps or better** USB Port: 2 USB port (USB2.0)minimum Hard disk interface: 2 SATA port suitable for 6TB each Protocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS Operating temp: -10 to 55 deg Cent Safety standard: UL
148SITC of 6 TB surveillance HDD
149SITC of 8 port Giga PoE switch, 8(PoE 10/100) + 2(10/100) port long distance switch
150Supply Installation testing Commissioning of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.17 U
151S/I/T/C ofLED Monitor full HD complying with the following specifications: Resolution : Full HD : 1920 x 1080 or better Backlight : LED Brightness : 400 NITS min. Video I/P port a) Min. 02 Nos HDMI 1920x1080. b) Min 01 No VGA Contrast : 1200 : 1 or better Power supply : 230v + / - 10%, 50 HzInstallation at sitewith connections andalong with all accessories of 42 INCHESetc.complete as required with min. 3 year onsite warranty.
152P/f of Hot press sheed moulded compound (SMC) Fire retardant (Temp. Resistance up to 200 C ) IP-55 weather proof pole box of inner dimension 300mm X 200mm X105 mm(NS) complete with suitable arrangment for fixing of 4 nos of 6 to32 amp single pole MCB & 63 Amp double pole isolator (MCB/Isolator excluded)with neutral link duly shorting on DIN channel with 2 nos. of MS clamps with SS back plate of suitalbe size with Danger monogramproperty printed on the cover etc as reqd.
153Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD- 63 MM andID 51 MM)
154Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
155Supply of following sizes of PVC insulated & PVC sheathed copper conductor 3 core submersible cable conforming to IS .694/2010 etc. as reqd. 3x 2.5 sqmm
156Supply Installation testing and Commissioning ofPigtails 1 meter with Splicing and testing.
157Supply Installation testing and Commissioning of opticalmedia converter gigabit SC to SC type up to 10 km.
158Supply Installation testing and Commissioning ofLIU boxes complete with all accessories etc. as required of 12 ports
159Supplying and laying of Optical Fiber Single Mode Cable (6-Fiber) on surface or in existing conduit etc complete i/cconnections etccomplete as required
160Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
161Big Screen Supplying, Installation, Testing and Commissioning of IP65 (front)Out door LED video wall having aluminium diecast cabinet material complete with 6 mm pixel pitch having brightness of5500nitsViewingAngle(horizontal/vertical) 160°/ 140°, contrast 4000:1, Physical density 27777dot/m2,Thedisplayshallbecompactable with various formats like M.S. office, PDF, PPT & Movieswithsuitablecontrollerfor operation on 230V, 50 HZ AC supply. the life span of video wall shallnotbe lessthen 1,00,000hrs.andOSDshall be16/32bitOSD.Videowallshouldbeoperated throughexistingPC/Laptop/IPLANPort.The boardshalloperateaspergivenformatcomplete withcomputercompatibilityetccompleteas required.
162Design,fabrication,supplying,installationof structural Iron frame work of Angle Iron 50mm x 50mm x 6mm thick on top and M.S pipe of 12" dia on bottom with base plate 10 mm thick duly groudedwithCCfoundationofsize900mmx 900mmx1200(deep) forinstallation/fixingof LEDwall and for withstand the wind pressure upto 150KMPH at height 18 ft (aprrox) from ground i/c cutting, hosting welding, grinding and installation/fixing by CC or dash fastner as the case maybeandapplyingonecoatofsteelprimerand twoormorecoatofsyntheticenameledpaintetc completeasperdirectionofEngineer-in-chargeas reqd.
163PA System SITC all weather proof loudspeaker forspeakers for otdoorground , having soundLF, HF - 1" exit Max SPL not less than 128db /1m (peak), with continuous RMS power of 45 - 55 Watt RMS with programme power of 90 – 110 WattRMS & peak power of 180 - 220 Watt RMS with minimum sentivity of 97db, Nominal Impedance : 8 ohms, nominal dispersion : 90 x 60, in birch plywood paint finish with wall mount bracket , suitable size MS frame box cover for protection etc. complete as required.
164Supply installation testing & commissioning of Professional total 16 channel audio mixer with 16 mic inputs; 2 line inputs 2 stereo inputs; with inbuilt effects and equalizer, graphic EQ etc. complete as reqd.
165Supply installation testing & commissioning of Dual Channel Power Class H/ D amplifier for Subwoofer & Main Speakers & outdoor speakers 2000 watt , Damping factor > 450, as required.
166Supply installation testing & commissioning of Cordless Handheld Microphone with UHF frequency (10 Selectable Frequencies) with 10 MV RF output, etc. complete as required.
167Supply, laying & Fixing of Speaker Lines: 2-Core, 2.5 sq mm High definition Speaker Cable, PVC insulated in PVC jacket laid in existing conduits as reqd.
168Supplying and laying of following size of C PVC pipein along with all accessories like socket, bend, couplers etc. confirming to IS :4985:2000, Part II complete with fitting and cutting, jointing etc.direct in ground (50 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 25 mm dia
169Supplying, installation, testing & commissioning of mixer amplifier mic input, USB input and Bluetooth, 50 Watt, at 240 volt AC supply complete etc as required.
170Supplying, installation, testing & commissioning of mixer amplifier mic input, USB input and Bluetooth, 75 Watt, at 240 volt AC supply complete etc as required.
171Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
172P/f of Hot press sheed moulded compound (SMC) Fire retardant (Temp. Resistance up to 200 C ) IP-65 weatherproof pole box of inner dimension 500mm X 400mm X200 mm(NS) complete with suitable arrangement to accommodate for fixing mixer amplifier complete as required
173Bollar Lighting Fabrication, supplying, installation, testing and commissioning of Bollard Light having length 750 mm of MS Sheet i/c making designe by Laser cutting,as approved by Engineer Incharge and welding the same,with 2 nos 10 watt warm white 2 feet long LED tube light fitting and having suitable arrangement to accommodate 2 nos 10 watt warm white 2 feet long LED tube light, duly painted with one coat of primer and two coat PU paint i/c J-type foundation nut bolt but excluding foundation complet etc. as required.
174Supplying and laying of following size of C PVC pipein along with all accessories like socket, bend, couplers etc. confirming to IS :4985:2000, Part II complete with fitting and cutting, jointing etc.direct in ground (50 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 25 mm dia
175Centering and shuttering including strulling, propping etc and removal of form for foundations footing, bases of columns, etc. for mass concrete.
176Providing 15 mm thick cement plaster of mix 1:4 (1 cement:4 fine sand) at all level.
177Providing and laying cement concrete in kerbs, steps and the like at or nearground level excluding the cost of centering, shuttering and finishing. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
178Cable Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
179Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 35 sq. mm and upto 95 sq. mm
180Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
181Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm
182Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
183Supply ofXLPE insulated,PVC sheathed Al.conductorArmoured Cable 1.1 KV grade Conforming to IS 7098 of following Sizes(a) 2x6sq.mm
184Supply ofXLPE insulated,PVC sheathed Al.conductorArmoured Cable 1.1 KV grade Conforming to IS 7098 of following Sizes(a) 2x10sq.mm
185Supply ofXLPE insulated,PVC sheathed Al.conductorArmoured Cable 1.1 KV grade Conforming to IS 7098 of following Sizes(a) 2x16sq.mm
186Supply ofXLPE insulated,PVC sheathed Al.conductorArmoured Cable 1.1 KV grade Conforming to IS 7098 of following Sizes(b) 4x50sq.mm
187SITC of Pillar box Size 900 mm x 450 mm x 250 mm suitable for mounting incomer of 250 A MCCB/Main Switch Pole and energy meter 3 phase complete with eleethoypic grade aluminium of bus bar 25mm x 10 mm mounted on galvanised M.S. body power quoted pilferage proof SMC door Welded with S.S. rain com size 40mm x 40mm x 5mm x 600mm height in cutting 300 mm height below ground and covered with shade proof SMC sheet of 3 mm as required.
188Provision of Software System -Web Application Admin Panel for remote access & real time data viewing along with MIS reports,Kiosk App for Ticket printing at Counter (Android),QR Scanner app for Entry Gate (Android),QR Scanner app for Exit gate (Android),Backend Software For online mode and online access,Backend Software for Offline mode and offline access
189Providing and fixing of Hardware System -At least 10-inch android tablet(6000mAH battery,2GB RAM,32GB ROM,charger) With screen Protector - 4 Nos., Smart Network Router(AC1750,802.1ac/up to 300+1450Mbps/gigabit) - 1 No,Thermal Printer (ethernet/LAN/auto cutter/150mm/sec) - 4 Nos., At least 6 inch Android Phone(5000mAH battery,2GB RAM,32GB ROM,13MP/5MP,charger) with screen Protector and Cover - 2 Nos., Manual/ Wireless Barcode/QR code Reader (Bluetooth 1D/2D scanning,ShockProof,charger) - 2 Nos., Metal Antitheft Tablet Floor Stands - 4 Nos.
190On Premise Physical Server with a minimum configuration of (Processor - [1*10C/20T 9.6GT/s, 13.75M Cache Processor (Expandable upto 2 processors)], RAM - [1*16GB RDIMM, 3200 MT/s dual rank (total 16 ram slots)], server management tool, Hard Disk - [2.4TB ,HDD 10K RPM ,Hot Plug 2*1.2TB for data failover (expandable upto 8 drives) RAID 1 + Controller +2GBNV Cache,DVDRW+Dual Power Supply (2*495W,instant failover capability),LAN (2*1Gbe LOM) ,UEFI/GPT),5 year onsite warranty
1914ft by 2.5ft Wooden Ply laminated desk/table for cash counter
192Black Metal lockable Cash Drawer/register/locker with Key and lock and 5 compartments for paper currency with Stainless Steel Clips and 8 compartments for coins [Size – 16.53inch (length) * 15.95inch (breadth) * 4.33Inch (height)] – connect with thermal printer/tablet for added security and easier cash management.
193Supply, Installation, Testing and Commissioning of LED RGB/RGBW floodlighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9 . Fixture shall be suitable to operate at an ambient temperature range of - 10°C to +50°C and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required . 45W
194Supply, Installation, Testing and Commissioning of LED RGB/RGBW floodlighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9 . Fixture shall be suitable to operate at an ambient temperature range of - 10°C to +50°C and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required . 30 W
195Supply, Installation, Testing and Commissioning of LED RGB/RGBW floodlighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9 . Fixture shall be suitable to operate at an ambient temperature range of - 10°C to +50°C and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required . 90W
196LED SMALL Projector Luminaire (12W-15W) SITC of Color Changing RGB/RGBW surface mounted Narrow/Medium beam Projector luminaire suitable for outdoor applications of Facade Lighting. Luminaires should be enabled with LEDs, should consists of highly efficient, UV and temperature-resistant optics with symmetric distribution. With glass cover, clear/powder coated. Luminaire luminous flux range 450-650 Lm, Luminaire should be Controlled through DMX/Ethernet protocol using DMX 512 Controller, Controller can achieve 16.7M colors. The luminaire should have options for various beam angles: 15°/25°. Power consumption should be between 12W to 15W at steady state full intensity. Luminaire dimesion should be max. 80mm diameter to meet site requirements. Power factor of the luminaire shall be more than 0.90. Luminaire should be provided with suitable integral/separate non-integral power supply unit. The lumen maintenance L70@ 25 °C of the LED shall not be less than 70% of the initial lumen after 50,000 burning hours. Ingress Protection should be IP 66 or higher. Housing should be made of pressure Die cast Aluminium with 3-4 mm thick safety glass. Impact resistance level should be suitable to site condition minimum IK07. Adequate heat sink with proper thermal management shall be provided. Operating Temperature.Operating Temperature : -10°C to +45°C, Operating Humidity : 10%-90%, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements.Luminaire Shall be BIS approved .
197LED SMALL Projector Luminaire (6W-)SITC of Color Changing RGB/RGB W surface mounted Narrow/Medium beam Projector luminaire suitable for outdoor applications of Facade Lighting. Luminaires should be enabled with LEDs, should consists of highly efficient, UV and temperature-resistant optics with symmetric distribution. With glass cover, clear/powder coated. Luminaire luminous flux range 280-480 Lm, Luminaire should be Controlled through DMX/Ethernet protocol using DMX 512 Controller, Controller can achieve 16.7M colors. The luminaire should have options for various beam angles: 8°/15°/20°/30°/45°. Power consumption should be between 5W to 10W at steady state full intensity. Luminaire dimesion should be max. 80mm diameter to meet site requirements. Power factor of the luminaire shall be more than 0.90. Luminaire should be provided with suitable integral/separate non-integral power supply unit. The lumen maintenance L70@ 25 °C of the LED shall not be less than 70% of the initial lumen after 50,000 burning hours. Ingress Protection should be IP 65 or higher. Housing should be made of pressure Die cast Aluminium with 3-4mm thick safety glass. Impact resistance level should be suitable to site condition minimum IK07. Adequate heat sink with proper thermal management shall be provided. Operating Temperature : -10°C to +45°C, Operating Humidity : 10%-90%, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. Luminaire Shall be BIS approved .
198Supply, Installation, Testing and Commissioning of LED RGB/RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270 V AC, 50 Hz, p+B14ower factor > 0.9 . Fixture shall be suitable to operate at ambient temperature range of -10°C to +50°C and shall be IP 65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required . 25 W
199Supply, Installation, Testing and Commissioning of LED RGB/RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270 V AC, 50 Hz, p+B14ower factor > 0.9 . Fixture shall be suitable to operate at ambient temperature range of -10°C to +50°C and shall be IP 65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required .40 W
200Supply, Installation, Testing and Commissioning of DMX Controller ,Input Power DC 5V-12V, 0.15A - 1A input, plug-in power adaptor included Power supply. Housing is made of Metal body with control switches for easy scene selections, programmable using DMX512 software through USB cable, internal storage capacityand additional SD card slot supporting upto 8GB storage of programming data. Compatible with interface XLR-3 / RJ45, for data transmission. housed inside IP66 protected enclosure with loop-in loop-out arrangement .
201Supply, Installation, Testing and Commissioning of DMX signal distribution device2V-24VAC power socket, suitable forsignal multiplication with Signal input with XLR-3-M; Output XLR-3-F, RJ45 .
202Supply, Installation, Testing and Commissioning of DMX cable for 22AWG, 7/0.254mm annealed tinned copper conductor with PP insulation, sheilded using aluminium foil with 100% coverage, PVC insulation .
203Supply, Installation, Testing and Commissioning of IP66 & IK09 protected, halogen free and silicon free as per IEC 60754-2, polycarbonate junction box of the size W 74 x H 74 x D 47 mm complete with all mounting and electrical accessories .
204Supply, Installation, Testing and Commissioning of IP66 & IK09 protected, halogen free and silicon free as per IEC 60754-2, polycarbonate junction box of the size W 170 x H 220 x D 96mm complete with all mounting and electrical accessories .
205Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required . 4Cx2.5
206Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required . 3Cx2.5
207Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required . 2Cx2.5
208Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required .
209Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required..
210Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required .
211P/Fof Hot Press Sheet Moulded Compound (SMC) , fire retardant (Temp. resistance up to 200 deg.C),IP-55 weather proof pole boxof inner dimension 200 mmx160 mmx98 mm (NS) complete with suitable arrangement for fixing of 4 Nos. of 6 to 32 amp Single pole MCB & 63 Amp. Double pole Isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with 2 Nos. of MS Clamps with SS back plate of Suitable Size with danger monogram property printed on the cover etc. as reqd .
212Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required . A)Single pole
213b)Single pole and neutral
214Supplying and fixing 40 A 4 Pole rating, 415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required .
215Supplying and fixing 63 A 4 Pole rating, 415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required .
216Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required . b) 125 A,36KA,FPMCCB
217Supplying offollowing size of G.I. Pipe (M- Class) i/c cutting threading on both sides etc ISI marked etc as reqd.. (a) 80 mm dia
218Supply, installation, Testing and Commissioning of power distribution control Panel made out of 2 mm sheet steel, powder coated gray paint shade RAL 7032 specially designed bus bar to provide safety suitable for accommodating MCCBs, 1 No, 400 Amp 50 KA FP MCCBas incoming, On Load Changeover of 400 Ampand 8 Nos 125 Amp FPMCCB as outgoing complete with 50 Hz 415 Volt AC Supply, prewired digital meter Module including Voltmeter, Ammeter with selector switch, CTs control fuse and indicating lights for outdoor type IP-55 etc as reqd. (8 ways)  .
219Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm .
220S/I/T/C of30W LED Flood Light warm white luminiare fitted with Lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following: (a) Total System Wattage 30 Watt +/- 5%. (b) Luminaire Efficieny>= 100 Lm/w (c ) Power Factor>= 0.95 (d) Protection Class- IP-66 .
221Providing and fixing of flexible LED strip fixtures suiatable for rated voltage 220 volts, 50 Hz supply in White /Green/Red/Warm white color including all accessories like connectors, Endcap,Holding Cap and connector pins but excluding integrated LED adoptor etc as required.
222Providing and fixing of Integrted LED Adaptor forflexibleLED strip fixtures suiatable for rated voltage 220 volts, 50 Hz supply etc as required.
223SupplyingandinstallationofONLINE UPS10 KVA /192 VDC Single Phase Input and Single Phase Output Online UPS System .
224SITC of 40 AH 12 volt Lead Acid Battery with Rack etc as required.
225Fabrication, supply & erection of following size flange mounted hot dip galvanized octagonal pole made from HT steel plate,window with flash cover with full verticle window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd,terminal block suitable for 25 sq mm conductor – 4 nos. & shorting links on DIN channel i/cpdg and fixing DIN channel of suitable length,, 6 Amp. SPMCB ‘C’ characteristics, earth stud, cable support clamp suitable for Upto 4x25 sqmm cable. Logo/Name of manufacturer shall be embossed on the Pole. Galvanization as per relevant IS. 5.0 mtr height, 3 mm thick, bottom dia of 130mm & top dia of 70mm base plate of size 225 x 225 x 12 mm thick
226Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm(L) x 450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -960mm long (approx.) - 8 nos. and reinforcement of cold twisted bar of 8 mm dia - 1400 mm (approx.) - 6 nos. (with 150 mm spacing) as required with supplying andpositioning of 4 nos foundation bolts size 16 mm dia, 600mm long, J type i/c 2 nos template anchor plates of size 225 mm x 225 mm x 3 mm and providing DWC HDPE pipe for cable entry & exit as required for 3 m and 5 mtr pole.
227Fabrication supplying and fixing Class B Galvanised single overhang arm bracket made out of 250 mm long galvanized top tube with cap & 1000 mm long 32 mm dia galvanized pipe with tightening bolts complete as reqd
228Supplying and erection of galvanised "D" iron clamps complete with shackle insulator (100 mm X 110 mm), G.I. bolts, nuts and washers, coach screws etc. as required.
229Supply of arms of GI pipe of size 20/25mm dia B classs 4 feet long bent medium grade with 25mm width 5mm thick MS clamps set 2 nos. with 3/8 nut and bolts for fixing of GI pipe in various sizes suitable to existing RCC/MS poles per relevent standard specifications.
230Installation Charges
231Providing and fixing of Stainless steel name plate of size 6x8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required.
232Maintenance of Sculptures The contractor shall be responsible for maintenance of all the Sculptures constructed under Waste to Art. The period of maintenance will be for ten years after from the date of completion date of defect liability period. The rate shall be quoted per Square Ft. of the Sculptures measurement, which are mentioned in the tender document. The rate quoted for maintenance of these sculptures shall be valid for ten years. The period may be extended further for next five years on existing terms and conditions and will be after consent from the successful contractor and on sole discretion of MCD to consider its extension or not. (At present the rates are to be quoted for one year maintenance cost given in this BOQ this will be fixed rate for two years and thereafter There will be an enhancement of rate by 5%on maintenance cost/rate of previous year after every two years of maintenance i.e. 3rd, 5th,7th year and so on.
233Manpower Deployment Providing Manpower Services (Un-Skilled, Semi-skilled & Skilled persons) such as Security Guards, Supervisors etc. for deployment at Bollywood Park under the Jurisdiction of Municipal Corporation of Delhi as per terms and conditions of MCD for a period of 10 years after completion of Construction work. Present requirement is for Mali, Security Guards & Supervisors (Total 25 Nos. ) which may vary depending on the requirement. MCD shall reimburse to contractor/bidder on actual basis of the Minimum Wages (Basic Rate) along-with Other Statutory Dues i.e. ESI, EPF, EDLI, Bonus, GST etc. at applicable rates notified by Delhi Govt. / Govt. of NCT of Delhi. The rate shall be quoted by the bidder on account of contractor Service Charges in percentage on minimum wages (Basic Rate only) only (FIXED Percentage on basic Minimum Wages) per person per month from MCD, inclusive of their own supervisory staff deployed and facilities being provided by the contractor to its labour such as uniform, washings etc. (At present the rates are to be quoted simultenously for monthly costing for 12 months cost given in this BOQ which will be also be followed for next years of the contract) The total costing for contractual cost for whole period will be calculated for award of work.
234Maintenance of Plants / Horticulture work. The bidder will be liable for proper plantation and maintenance of all Horticulture Work,work already available at site and new work to be done. The Rate shall be quoted per Month for maintenance of all Horticulture work for a period of 10 years. At present the rates are to be quoted for 12 months period maintenance cost given in this BOQ this will be fixed rate for two years and thereafter There will be an enhancement / increment in the rate of maintenance cost @7% after every year on the maintenance rate / cost of previous year.
235Maintenance of all Civil Works. The bidder will be liable for proper maintenance of all Civil Works & infrastructure, which include work already available at site / project and new work to be done in this phase. The Rate shall be quoted per annum for maintenance of all Civil works / infrastructures for a minimumperiod of 10 years. At present the rates are to be quoted for 12 months period maintenance cost given in this BOQ this will be fixed rate for two years and thereafter There will be an enhancement / increment in the rate of maintenance cost @7% after every year on the maintenance rate / cost of previous year.
236Maintenance of all Electrical Works / Equipments. The bidder will be liable for proper maintenance of all Electrical Works / Equipments, which include work already available at site and new work to be done in this phase. The Rate shall be quoted per annum for maintenance of all Electrical Works / Equipments for a minimumperiod of 10 years.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail