| 1 | Civil Work |
| 2 | Supplying, fitting and fixing boiling water resistant ply conforming to IS: 303-1989 bonded with phenol formaldehyde synthetic resin of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in- Charge.[excluding the cost of supporting frame work and teak wood batten/Lipping] In Ground Floor. (vi) 19mm |
| 3 | Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge. The rate includes the cost of labour, adhesive and all incidental charges thereof. In ground floor. Glossy/Matt/Suede excluding surface texture or metallic lustre.(ii) Thickness of laminate 1 mm |
| 4 | Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. (a) Area of each Granite slab 0.6 to 1.0 Square meter |
| 5 | Supplying, fitting & fixing best quality digital printed Ceramic tiles in coloured decorative on walls and floors to match with the existing work & 4 nos. key stones (10mm) fixed with adhesive 4.5 mm thick at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. With polymerised adhesive and epoxy grout pointing including spacer - 2mm (When tiles are laid over existing hard ready surface) all complete as per direction of Engineer-in-charge. |
| 6 | Supplying, fitting & fixing of Aluminium fixed partion wall of all aluminium sections viz top, bottom and side member, intermediate member, glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium fixed partition wall with glass / panel board all complete as per architectural drawings and direction of Engineer-in-charge. (Excluding cost of glass/ panel board, 10-12 Micron thickness Annodizing film. Natural white..b) For unsupported length of vertical member above 1.50m. height of both ends of vertical member restrained but panel above 0.90 sqm |
| 7 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.v) 6mm thick clear glass. |
| 8 | (B) Supplying 125 mm. Dia acrylic handle for aluminium door as per approved make & brand. (a) Natural Colour |
| 9 | Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP) (a) 3mm thick (0.25mm Al.+2.5mm LDPE +0.25mm Al. PVDF coating) |
| 10 | Supplying heavy duty hydraulic double action floor spring along with top pin/set of pivots conforming to IS: 6315 or any approved make as per direction of Engineer in charge. |
| 11 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. |
| 12 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[ (ii) With 1:4 cement mortar. (b) 15 mm thick plaster |
| 13 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer\"s specification) including cleaning and smoothning of surface. Two Coats |
| 14 | R.C. shelves (1:1.5:3) either precast or cast in situ with stone chips and necessary reinforcement upto 1% (0.8% main and 0.2% distribution bars), shuttering etc. and 10 mm. thick cement plaster (1:4) including neat cement finishing and cutting chase fitting and fixing in position, mending good damages as necessary complete. In ground floor(a) 50 mm. Thick panels. I. SAIL/ TATA/RINL |
| 15 | Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film |
| 16 | Supplying, fitting and fixing White Vitreous China Sink in position on C.I. brackets including two coats of painting of brackets.(ii) 610 mm X 450 mm X 250 mm |
| 17 | f) (ii) CP 2-way bib Cock - 15 mm, supplied, fitted and fixed. |
| 18 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing .............etc. 25 mm |
| 19 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing .............etc. 50 mm |
| 20 | Distribution wiring in 1.1 KV, 3x1.5 sq.mm. single core stranded \"FR\" PVC insulated& unsheathed copper wire (Finolex, Havell’s) in suitable size PVC casing-capping (Pesto/ Precision) incl. necy. fittings etc. to light point with Modular type switch (Cabtree) fixed on Modular PVC switch board with top cover plate on wall incl. mending good damages to original finish. Av. Run- 5 mtr. Total points- 4 nos.i) Single tube light -4 nos. |
| 21 | S and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Finolex, Havell’s) of the following sizes in 25 mm PVCcasing-capping (Precision/ pesto) and making necy. connection as required. a) 3x1.5 sq.mmforexisting SPN DB to Switch board. |
| 22 | S and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Finolex, Havell’s) of the following sizes in 25 mm PVCcasing-capping (Precision/ pesto) and making necy. connection as required.b) 2x 2.5 +1x1.5 Sq mm forpower points. |
| 23 | S and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Finolex, Havell’s) of the following sizes in 25 mm PVCcasing-capping (Precision/ pesto) and making necy. connection as required b) 2x 4 +1x1.5 Sq mm forAC points |
| 24 | Supply & Fixing 240 V, 2x 6/16 A, 3/5 pin Modular type plug socket (Legrand) with 16A Modular type switch, without plug top on GI Modular type switch board with top cover plate on wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. forpower points. |
| 25 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket with 20/25A Modular switch (Make- Legrand )type SP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. for AC. |
| 26 | Supply & Fixing 240 V, 25 A, Modular type starter (Make- Legrand) with 25A Modular switch type DP MCB (\"C\" Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc for AC. |
| 27 | Supply of 240 volt,18/20 watt single LED tube light fittings(2\" or 4\" if required) [Cat. No – Frame – Crompton ECO – model – DIJB12L-T8-20, Tube – Crompton – Secure -model – LTT8-20 or equivalent Havells, Philips]. For instrument table. |
| 28 | Shifting and re-fixing of switch board and alide electrical works if required. |